Tender For Provision Of Accommodation At Bathinda Mil.Stn., bathinda-Punjab

Military Engineer Services-MES has published Tender For Provision Of Accommodation At Bathinda Mil.Stn.. Submission Date for this Tender is 15-06-2024. Building Work Tenders in bathinda Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

43330773
Tender For Provision Of Accommodation At Bathinda Mil.Stn.
Open Tender
Indian
Punjab
bathinda
15-06-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Provision Of Accommodation At Bathinda Mil.Stn.; 2.00 General Summary 2.01 Lump Sum Price Worked Out By The Contractor For Building Works As Listed In Schedule ‘A’ Part- I ( Ref Prepriced Schedule Attached Seperately ) 2.02 Lump Sum Price Worked Out By The Contractor For Internal Water Supply Works As Listed In Schedule ‘A’ Part- Ii ( Ref Prepriced Schedule Attached Seperately ) 2.03 Lump Sum Price Worked Out By The Contractor For Internal Electrification Works As Listed In Schedule ‘A’ Part- Iii ( Ref Prepriced Schedule Attached Seperately ) 2.04 Lump Sum Price Worked Out By The Contractor For External Water Supply Works As Listed In Schedule ‘A’ Part- Iv ( Ref Prepriced Schedule Attached Seperately ) 2.05 Lump Sum Price Worked Out By The Contractor For External Eletric Supply Works As Listed In Schedule ‘A’ Part- V ( Ref Prepriced Schedule Attached Seperately ) 2.06 Lump Sum Price Worked Out By The Contractor For Road , Path , Hardstanding And Culvert Works As Listed In Schedule ‘A’ Part- Vi ( Ref Prepriced Schedule Attached Seperately ) 2.07 Lump Sum Price Worked Out By The Contractor For Steel Gate & Compound Wall Works As Listed In Schedule ‘A’ Part- Vii ( Ref Prepriced Schedule Attached Seperately ) 2.08 Lump Sum Price Worked Out By The Contractor For Sewage Disposal Works As Listed In Schedule ‘A’ Part- Viii ( Ref Prepriced Schedule Attached Seperately ) 2.09 Lump Sum Price Worked Out By The Contractor For Area Drainage Works As Listed In Schedule ‘A’ Part-Ix ( Ref Prepriced Schedule Attached Seperately ) 2.10 Lump Sum Price Worked Out By The Contractor For Hot Water Appliances Works As Listed In Schedule ‘A’ Part-X ( Ref Prepriced Schedule Attached Seperately ) 2.11 Lump Sum Price Worked Out By The Contractor For Summer Appliances Works As Listed In Schedule ‘A’ Part-Xi ( Ref Prepriced Schedule Attached Seperately ) 2.12 Lump Sum Price Worked Out By The Contractor For Excavation, Earth Work And Site Development Works As Listed In Schedule ‘A’ Part-Xii ( Ref Prepriced Schedule Attached Seperately ) 3.02 Supply And Fixing 15Mm Bore Angle Valve / Cock Fancy Type, Cast Copper Alloy Chromium Plated Screwed Down High Pressure, Screwed Both Ends For Iron Pipe Or Unions And Fixed, Complete All As Specified & As Directed. 3.03 Supply & Fixing 2 Way Bib Tap 15Mm Bore , Fancy Type Cast Copper Alloy Chromium Plated With Crutch Or Butterfly Handle, Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule And Fixed Complete All As Specified And Directed.

Key Value

Document Fees
INR 1000 /-
EMD
INR 178500.0 /-
Tender Value
INR 1.03 Crore /-

Attachment

FileName File Description File Size
9b15e488-3747-4bc7-9916-ff526d0f1a54.html Tender Notice 0 KB
8117NIT.pdf Tender Document 0 KB
8117TenderDocu.pdf Tender Document 0 KB
BOQ_730818.xls Tender Document 0 KB
Drgsoftender.rar Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work:PROVN OFACCN AT BATHINDA MIL.STN. JOB NO.81/BTD/AMWP-01/2022-2023
Sl. No. Item Description
1Note:-Please refer schedule "A" notesbefore quoting the tender.
2GENERAL SUMMARY
3Lump sum price worked out by the contractor for BUILDING WORKS as listed in Schedule ‘A’Part- I (Ref prepriced schedule attached seperately)
4Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’Part- II (Ref prepriced schedule attached seperately)
5Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKSas listed in Schedule ‘A’Part- III (Ref prepriced schedule attached seperately)
6Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKSas listed in Schedule ‘A’Part- IV (Ref prepriced schedule attached seperately)
7Lump sum price worked out by the contractor for EXTERNAL ELETRIC SUPPLY WORKSas listed in Schedule ‘A’Part- V (Ref prepriced schedule attached seperately)
8Lump sum price worked out by the contractor for ROAD,PATH , HARDSTANDING AND CULVERT WORKS as listed in Schedule ‘A’Part- VI (Ref prepriced schedule attached seperately)
9Lump sum price worked out by the contractor for STEEL GATE& COMPOUND WALLWORKSas listed in Schedule ‘A’Part- VII (Ref prepriced schedule attached seperately)
10Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule ‘A’Part- VIII(Ref prepriced schedule attached seperately)
11Lump sum price worked out by the contractor for AREA DRAINAGE WORKSas listed in Schedule ‘A’Part-IX(Ref prepriced schedule attached seperately)
12Lump sum price worked out by the contractor for HOTWATERAPPLIANCES WORKSas listed in Schedule ‘A’Part-X(Ref prepriced schedule attached seperately)
13Lump sum price worked out by the contractor for SUMMER APPLIANCES WORKSas listed in Schedule ‘A’Part-XI(Ref prepriced schedule attached seperately)
14Lump sum price worked out by the contractor for EXCAVATION, EARTH WORK AND SITE DEVELOPMENT WORKS as listed in Schedule ‘A’Part-XII(Ref prepriced schedule attached seperately)
15SCH "A" Pt - XIII (MISCELLANEOUS ITEMS) (Contains Ser item No 3.01 to Ser item No 10.04)
16INTERNAL WATER SUPPLY NOTE:- For items of internal water supply notes given at the beginning of Sch ‘A’ Part-II (Internal Water Supply) shall also be applicable.
17Supply and Fixing 15mm bore angle valve / cock fancy type, cast copper alloy chromium plated screwed down high pressure, screwed both ends for iron pipe or unions and fixed, complete all as specified & as directed.
18Supply & Fixing 2 way Bib tap 15mm bore , fancytype cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
19INTERNAL ELETRIFICATION NOTE:- For items of internal Electrifications notes given at the beginning of Sch ‘A’ Part-III (internalElectrification) shall also be applicable.
20Material and Labourconcealed Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with 1.5 Sqmm nominal cross sectional area PVC insulated unsheathed multi-stranded FRLSH copper conductor1100 volts grade, drawnin and including medium grade, rigid PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc,ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories), and includingmodular metal flush boxes concealedwith modular natural / white finish front plate with base plate for the mountingof modular switches, sockets and fan regulators etc. etc including1.5 Sqmm nominal cross sectional area PVC insulated unsheathed multi-stranded FRLSH copper conductor cable as earth continuity conductor to common earth dollycomplete all as specified and directed for the following:- NOTE:- The quoted unit rate is deemed to be inclusive of cost of metal flush boxes, modular white cover plates, modular frame plates, etc.However modular switches,modular sockets and regulators shall be measured and paid seperately under respective items of Schedule"A" BoQ.
21One light pointcontrolled by one 6 amps one way modular switch.
22One light point controlled by two6 amps two way modular switch.
23One modularSocket outlet, 6 Amp, 2/3 Pin controlled byone 6 amps one way modular switch or modular switch/ socket combination 6 Amps, 2/ 3 Pin on the same board.
24One modularSocket outlet, 6 Amp, 2/3 Pin controlled byone 6 amps one way modular switch or modular switch/ socket combination 6 Amps, 2/ 3 Pin on independent board and not below the any other switch board.
25Material and LabourPoint wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with 2.5 sq mm nominal cross sectional area PVC insulated unsheathed multi-stranded FRLSH copper conductor1100 volts grade, drawnin and including 20mm dia medium grade, rigid PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc,ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories), and includingmodular metal flush boxes concealedwith modular natural / white finish front plate with base plate for the mountingof modular switches,and modular socketsetc. etc including2.5 Sq mm nominal cross sectional area PVC insulated unsheathed multi-stranded FRLSH copper conductor cable as earth continuity conductor to common earth dolly NOTE:- The quoted unit rate is deemed to be inclusive of cost of metal flush boxes, modular white cover plates, modular frame plates, etc.However modular switches and modular socketsshall be measured and paid seperately under respective items of Schedule"A" BoQ.
26Material and Labourfor Sub main wiringconcealed PVC conduit with two single core of size 10 SqmmFRLS PVC insulated unsheathedwith multistranded copper conductor cable 1100 volts gradedrawn in and including non metallic rigid PVC conduit medium quality of size 25 mm dia conforming to 3537 Part-IISI marked includingone single core of size 10 SqmmFRLS PVC insulated unsheathedwith multistranded copper conductor cable 1100 volts gradeasin contineous earth conductor cable connected to earth dolly complete all as directed.(Colour code phase-Red, Nuetral-black and Earth as Green) complete all as specified & directed.Notes:-(a) Cost of PVC conduit , conduit accessories i.e. PVC Clamp, rawl plug, screws, PVC junction box, Tee, bend etc. and earth wire included in sub main wiring and nothing shall be paid extra on this account. (b)Threesingle core10Sqmmcable including non metallic rigid PVC conduit of size 25 mm dia shall be measured as one length.
27Supply and FixingMCB SPN 16 amps 10 KA , 240, "B" Curve including connection with suitable sizecopper lugs complete all as specified and directed
28Supply and fixing (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 250 Amp rated bus bar) VTPN, 4 Way 415V, suitable for mounting MCCB/MCB, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge.
29Supply and fixing energy efficient LED security light fitting of 25W pressure die cast aluminium housing/body, heat resistant clear toughened glass,better optics for uniform distribution street luminaire, with driver, including electric connection with using 3 core flexible copper conductor cable 1.5Sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of GI tubing light grade 25mm dia, 1.2 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt.(b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95(e) THD : Max10%.(f) IP rating : IP66. (g) IK rating:Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire.(j) LED driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI: Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
30Supply and fixing LED lamp minimum 3 star rated 12 W LED B-22 base complete all as specified and directed by Engr-in-Charge with following specifications (a) Lumen system efficacy of lamp should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C
31Supply and fixing LED tube light fitting polycarbonate housing 1 x 20Watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt.(b) Input Voltage range : 140 to 270 volts.(c) Temp operating range : Minus 5°C to Plus 45°C(d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5%(f) IP rating : IP-20.(g)LED Driver of the same make as of the luminaire.(h) LED driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6000K(l) CRI : Minimum 80 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
32Supply and fixingLED light fitting 1 x 10Watt, appx 2 feet long with decorative ultra ceiling square profile linear LED lighting fixture with extruded polycarbonate environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting,complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 5°C to Plus 45°C(d) Power factor : Minimum 0.95(e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) CRCA pre coated housing with plastic end cap.(h) LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV.(l) CCT : Minimum 6000K(m) CRI : Minimum 80(n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
33Supply and fixing LED Luminaire 600 mm x 600 mm, 35/36 watt, 220V AC recessed type with high efficiency PMMA diffuser soft free light complete with driver, holders LED Lamp suitable for roof ceiling including connecting up with dirver three core flexible copper conductor with complete point wiring of size 1.5 sqmm and switch board including earth wire 1.5 Sqmm copper conductor complete all as specified and directed by Engineer-in-Charge.
34EXTERNAL WATER SUPPLY NOTE:- For items of EXTERNAL WATER SUPPLY notes given at the beginning of Sch ‘A’ Part-IV ( EXTERNAL WATERSUPPLY ) shall also be applicable.
35Material and Labour forCutting of Existing CI / DI /GI Pipe line up to 150mm bore for taking branch connection , insertingwith and including one no. DI Teeflanged Typeof size 150mm x 150mm x 40mm along with two tail pieces of 150mm boreone end flanged and other end socket ,including necessary jointingmaterial i.e ,nuts, bolts,washers , etc. completeall as specified and directed. Note: The rate of one no. DI Teeflanged Typeof size 150mm x 150mm x 40mm along with two tail pieces of 150mm boreone end flanged and other end socket ,including necessary jointingmaterial i.e ,nuts, bolts,washers , etc.is included in this item and nothing shall be paid extra on this account.
36Material and LabourConstruction of brick masonary valve pit chamber of internal size 750mm x 750mm x 750mm , PCC 1:4:8 type D2 using( 40mm graded stone aggregate )lean concrete infoundation , providing old size well burnt claybrick masonary wall of 230mm thick built in Cement Mortar1:4 , Rendering 15mm thick in cement mortar 1:4 finished even and fairinternally ,supply and fix 3.15 mm thick MS sheet steel cover fixed on 50mm x 50mm x 6mm thick angle ironframe , embeded in PCC coping with PCC 1:2:4 type-B1 using 20mm graded stone aggregates, with locking arrangement and 1 No. 50mm size 4 levers lock with key in duplicate Standard size and MS hold fast and handle made out of 25mm x 6mm flat iron and applyingtwo coats of synthetic enamel paint of approved shade over a coat of primer (Red Oxide zinc chromate primer ) to all exposed surface including earth work i.e. excavation, returing filling and removal ofsoil complete all as specified and as directed andall as shown on drawings No.BTD-811 sheet 1/2 to 2/2 Note:- The rate of earth work i.e. excavation, returing filling and removal of soil is included in thisitem and nothingshall be paid extra on this account.
37EXTERNAL ELETRIC SUPPLY NOTE:- For items of EXTERNAL ELECTRIC SUPPLY notes given at the beginning of Sch ‘A’ Part-V ( EXTERNAL ELETRIC SUPPLY) shall also be applicable.
38Supply, installation, commissioning and testing of LT Feeder Pillar Type Panel of suitablesizesuitable to accomdate mentioned accessories , factory made (CPRI approved) outdoor cubicaltype ,double door both side openable with hinged doors & locking arrangement made out of not less than 3.15 mm thick mild steel CRCA sheet supported and fixed on structural frame of angle iron of size 50mm x 50mm x 6mm angle iron frame including earthing stud lebeling, painting to all internal & external exposed steel surfaces withpowder coating paint (7 stage process)( colour as approved by GE), duly fixed in ground with PCC foundation(1:2:4) type B1 with danger notice plate of 1.6mm thick mild steel sheet, vitrious enamelled (white) with letters figures and conventional skull and bones in signal red colour complete all as specified anddirected. comprising of the following accessories :-
39Contd/- serial item No.6.01Incoming:- (a)Copperbus bar 100 Amps rated capacity suitable for 4 wire 415 volt,50Hz AC system with insulated sleaves and making connections with single core copper multistranded conductor PVC insulated of size 10.00Sq mm wires in color code (b) MCCB 63 Amp, 4 Pole, 25 KA (Icu=100%Ics) with adjustable thermal release 0.8 to 1.0 and fixed magnetic type-01 No.(Incomer) (c) MCCB 40 Amp, 4 Pole, 16 KA (Icu=100%Ics) with adjustable thermal release 0.8 to 1.0 and fixed magnetic type-01 No.(Admn Block) (d) MCB DP,6 Amp to 20 Amp,240 Volt ,"C" curve ,,10KA-03 Nos.(Out goint: Garrage, street light and Gate light) (e) Digital voltmetre -01 No.(f) Digital Ammetre with CT -01 Set (g) Neon indicator lamp with holder (Yellow, Blue,Red)- 01 set (Set of three)
40Supply& FixingEnergy Efficient LED Street Light fittings 45 Watt, 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protectioncapacity of lumen system efficacy of luminarie should be minimum 100 lumen per watt complete all as per manufacturer"s instructions and complete all as specified and directed by Engineer-in-charge.Note :- 1.The cable for connection shall be measured and paid seperately under respective item of Schedule "A" BoQ.
41Supply& Fixing DecorativeLED Post Top Lantern Luminior with IP-65 protection die cast aluminium spigot, spun aluminium powder coated, top cover clear/opal acralic, difusser LED Light fitting of 15 watt including LED lamp complete all as per manufacturer"s instructions and complete all as specified and as directed. Note :- 1.The cable for connection shall be measured and paid seperately under respective item of Schedule "A" BoQ.
42Supply & FixingThree core cord flexible wire, copper conductor multistranded,PVC insulated and overall PVC sheathed of size 1.5 Sqmm 1100 voltcomplete all as specified and as directed
43Supply & Fixing Thermoplastic (Polystreen)Junction Box having IP 66 protection of size130mm x 180mm x 77 mm in size,fixed to pole / wall with MS clamps of size 25mm x 3mm ,nuts, bolts, washers etc. , terminal of same company having provision of 3 phase aluminium bus bar with and including one no. MCB 6 Amp SPN "C" Curve, clamps of size 25mm x 3mm complete all as specified and as directed.Note: The rate of one no. MCB 6 Amp SPN "C" Curveandclamps of size 25mm x 3mm is included in this item and nothing shall be paid extra on this account.
44Material and Labour for Making the holeunder road / pavement / hardstanding for laying of GI tube light grade 50mm bore as required at site by mechanical drill system or Auger system and making the surface good as per existing surface complete all as specified and directed. Note : The GI tube light grade 50mm boreshall be measured and paid as material and labour seperately under respective item of Schedule "A" Part-V EXTERNAL ELECTRIC SUPPLY WORKS
45Material andLabour sand cushioning, with dry and cleansand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified. (Note:- Punned thickness shall be considered for payment purpose)
46ROAD,PATH , HARDSTANDING AND CULVERTWORKS NOTE:- For items of ROAD,PATH , HARDSTANDING AND CULVERT WORKS notes given at the beginning of Sch ‘A’ Part-VI (ROAD,PATH , HARDSTANDING AND CULVERTWORKS) shall also be applicable.
47Material andLabour 100mm thickCement Concrete (1:2:4)Type- B-1 , using 20mm graded stone aggregate as in edging for stoping the end of interlocking tiles complete all as specified & directed.
48STEEL GATE& COMOUND WALL WORKS NOTE:- For items ofSTEEL GATE& COMOUND WALL WORKS notes given at the beginning of Sch ‘A’ Part-VII ( STEEL GATE& COMOUND WALL WORKS) shall also be applicable.
49Material andLabourfor Steel Gate 5.5 mtr wide and 2.7mtr height complete all as shown on drawing No. BTD-79 complete all as specified and directed.
50HOTWATERAPPLIANCES NOTE:- For items of HOTWATERAPPLIANCES notes given at the beginning of Sch ‘A’ Part-X ( HOTWATERAPPLIANCES ) shall also be applicable.
51Material and Labourfor Sub main wiringconcealed PVC conduit with two single core of size 2.5 SqmmFRLS PVC insulated unsheathedwith multistranded copper conductor cable 1100 volts gradedrawn in and including non metallic rigid PVC conduit medium quality of size 20 mm dia conforming to 3537 Part-IISI marked includingone single core of size 2.5 SqmmFRLS PVC insulated unsheathedwith multistranded copper conductor cable 1100 volts gradeasin contineous earth conductor cable connected to earth dolly complete all as directed.(Colour code phase-Red, Nuetral-black and Earth as Green) complete all as specified & directed.Notes:-(a) Cost of PVC conduit , conduit accessories i.e. PVC Clamp, rawl plug, screws, PVC junction box, Tee, bend etc. and earth wire included in sub main wiring and nothing shall be paid extra on this account. (b)Threesingle core2.5Sqmmcable including non metallic rigid PVC conduit of size 20 mm dia shall be measured as one length.
52SUMMER APPLIANCES NOTE:- For items of SUMMER APPLIANCES notes given at the beginning of Sch ‘A’ PART-XI SUMMER APPLIANCES shall also be applicable.
53Supply , Fixing , Testing and commissioningWater cooler fully stainless steel, Electric Driven, Single Phase , having storage capacity 40 Liters and nominal cooling capacity 40 Liters per hour complete all as per manufacturer"s instructions and complete all as specified and as directed.
54Supply , Fixing , Testing and commissioningVoltage stabilizer for automatic operation , single phase, copper wound,of capacity 2 KVA,naturally air cooled , indoor type , and designed for input variation between 170 volt to 250 volt with out putvoltage stablized 230 volt , with accuracy of +/- 2.5% ,mounting bracket complete with time delay relay complete all as per manufacturer"s instructions and complete all as specified and as directed.
55Supply , Fixing , Testing and commissioningDesert cooler of size 26" x 26" x 33" or next available higher size having nominal air flow capacity 3000 cubic metre per hour single phase 240 volts 50Hz made out of plain GI Sheet of 18SWG and side panels of 22 SWGcompleteall as specified and as directed.
56Supply , Fixing Rotational moulded double lahyer polyethylene water storage tanks (cylindrical vertical with closed top) of capacity 500 Liters,hoisted and fixed in position all as specified in SSR Part Icompleteall as specified and as directed.
Disclaimer :