Tender For Special Repair Of Exterior Face, Beams, Drainage And Balconies At Satyakam Bhawan, University Of Delhi., Delhi-Delhi

Delhi University has published Tender For Special Repair Of Exterior Face, Beams, Drainage And Balconies At Satyakam Bhawan, University Of Delhi.. Submission Date for this Tender is 28-05-2024. Building Work Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

43328481
Tender For Special Repair Of Exterior Face, Beams, Drainage And Balconies At Satyakam Bhawan, University Of Delhi.
Open Tender
Indian
Delhi
Delhi
28-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Special Repair Of Exterior Face, Beams, Drainage And Balconies At Satyakam Bhawan, University Of Delhi.

Key Value

Document Fees
INR 1000 /-
EMD
INR 237787.0 /-
Tender Value
INR 1.18 Crore /-

Attachment

FileName File Description File Size
b8c41d55-d417-4225-a72c-241a77e75913.html Tender Notice 0 KB
BOQ_847670.xls Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: Special repair of exterior face, beams, drainage and balconies at Satyakam Bhawan, University of Delhi.
Sl. No. Item Description
1Providing and fixing hard drawn steel wire fabric of size 75 x25 mm mesh or other suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of "L" shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & plants as approved by Engineer-in-charge.
2Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge
375 mm average thickness
450 mm average thickness
5Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make.
6Supplying and installation of moisture resistant/fire resistant cement board as per standard sizes fixed with self-drilling / taping screws. Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. Cement Fiber Board 6 mm thick as per IS 14862:2000 of type B (High pressure Steam Cured)
7Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10(1cement:5coarsesand(zone-III):10 graded stone aggregate 40 mm nominal size)
8Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) at window sills, ceiling level and the like. Cement mortar 1:6 (1 cement : 6 coarse sand).
9Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : In cement mortar
10Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer) with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make in all colours & shade in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
11Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade(0.10 kg of hardener and 0.20 kg of resin per kg), including filling/grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm
12Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
13For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
14For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). Powder coated aluminium (minimum thickness of powder coating 50 micron)
15Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
16Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS:12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides
17Pointing on tile brick work with cement mortar 1:3 (1 cement: 3 fine sand) : Flush / Ruled/ Struck or weathered pointing.
18Pointing on stone work with cement mortar 1:3 (1 cement: 3 fine sand) : Flush/ Ruled pointing
19Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge.
20Extra for pointing on walls on the outside at height more than 10 m from ground level for every additional height of 3 m or part there of.
21Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete.
22Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
23Painting (two or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on new work. 150 mm diameter pipes
24Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift upto1.5 m. All kinds of soil.
25Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.. In cement mortar
26Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work.
27Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 100 to 250 mm diameter
28Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer-in-Charge : Rectangular manhole 90x80 cm and 45 cm deep
29Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
30Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall 50 mm nominal outer dia. Pipes.
31Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 50 to 80 mm nominal bore
32Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. : 150 mm diameter
33Providing lead caulked joints to sand cast iron rain water pipes and fittings : 150 mm dia. Pipe
34Providing, fixing and embedding sand cast iron accessories for rain water pipes in the masonry surrounded with 12 mm thick cement mortar of the same mix, as that of masonry (lead caulking will be paid for separately) : Sand cast iron plain shoes : 150 mm diameter
35Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. : Internal work – Exposed on wall.
3620 mm dia. nominal bore
3725 mm dia. nominal bore
3832 mm dia. nominal bore
3940 mm dia. nominal bore
4050 mm dia. nominal bore
41Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required :
4220 mm nominal bore.
4325 mm nominal bore.
4432 mm nominal bore.
4540 mm nominal bore.
4650 mm nominal bore.
4765 mm nominal bore.
4880 mm nominal bore.
49Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :
5020 mm diameter pipe.
5125 mm diameter pipe.
5232 mm diameter pipe.
5340 mm diameter pipe.
5450 mm diameter pipe.
55Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. : External work 80 mm dia. nominal bore
56Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles
57Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineerin- Charge Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 50mm thick in Grade M 25 with cement content not less than 330 kg per cum
5815 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand)
59Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
60Laying old cement concrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer in-charge. (Old CC paver blocks shall be supplied by the department free of cost).
61Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40mm dia. M.S. tube 1.5m centre to centre horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge .The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done.
62Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
63Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
64Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
65Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete.
66Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge.
67Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick.
68Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead
69Repair of aluminium door, window i/c taking out, repair & refixing with rubber gaskit, aluminium beading etc complete as per direction of Engineer-in-charge.
70Providing and fixing 20mm DRP G.M. BRASS GATE VALVE ISI complete as per direction of Engineer in charge.
71Providing and fixing 25mm DRP G.M. BRASS GATE VALVE ISI complete as per direction of Engineer in charge.
72Providing and fixing 32mm DRP G.M. BRASS GATE VALVE ISI complete as per direction of Engineer in charge.
73Providing and fixing 40mm DRP G.M. BRASS GATE VALVE ISI complete as per direction of Engineer in charge.
74Providing and fixing 50mm DRP G.M. BRASS GATE VALVE ISI complete as per direction of Engineer in charge.
75Providing and fixing soil, waste and vent pipes :150 mm dia Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 complete as per direction of engineer in charge.
76Providing and fixing single equal plain junction of required degree : 150x150x150 mm Sand cast iron S&S as per IS - 3989
77Labour charges for taking out loose kota stone, removing mortar, making smooth surface and refixing the same with 20 mm (avg.) thick base laid over and jointed with grey cement slurry mixed with pigment the match the shade of the slab i/c rubbing etc complete with base of mortar 1:4 etc complete as per direction of Engineer-in-charge
78Providing and fixing Fastner 100mm to 180mm on Granite, Stone, C.C. /R.C.C./Brick masonry etc. surface including drilling necessary holes and the cost of washer,bolt etc complete. complete as per direction of engineer in charge.
79P/F pre-cast RCC man hole cover & frame of size600x450 mm KK brandMHCF-16 MD including c.c work required complete as per direction of Engineer in charge.
80P/F pre-cast RCC man hole cover & frame of size450x450 mm KK brand MHCF-15 MD ( Rainwater ) including cement concrete work required complete as per direction of Engineer in charge.
81Providing and fixing Aluminum Wall/ Door Hanger as per direction of Engineer-in-charge
82Providing and fixing roller blinds of approved quality and make as per direction of engineer in charge.
83Providing and making steel pole collar with cement concrete (1:3:6) Cement:sand: 20mm concrete) of specified size and shape including form work, plastering if required, curing etc. as required(Volume of pole /pipe not to be deducted)
84Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
851 x 1.5 sqmm
862 x 2.5 sqmm
872 x 4 sqmm
88Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
895 amp switch
905 amp socket
9115 amp switch
9215 amp socket
93Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
943 Module
956 Module
968 Module
9712 Module
98Supplying and fixing 2/1 module stepped type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as reqd
99Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
10020 mm
10125 mm
102Supply, Testing and commissioning of HOT dip galvanized octagonal steel pole of 3 mtr height made out of 3mm thick sheet PCD 200 mm, having bottom 130mm A/F & top 70mm A/F with built in connector box of size 500 mm length, M.S. base plate of size 200mm x 200mm x12mm thick, suitable GI bracket made of 3.60 mm thick GI pipe with 500 mm long top galvanized MS tube of suitable dia to accommodate the fittingon existing RCC foundation i/c S/F of 4 Nos. M-16 x 450mm long J Type (EN-8 grade) G.I. foundation bolts & nuts with 3 Nos. and 2 Nos. washer along with suitable size templates, making connections, interconnections with suitable size of copper wire with thimble/lugs in the connection box, earthing, making numbering of pole etc complete as per drawing & technical specifications attached including following accessories mounted on inbuilt control box having flush cover with 2 Nos mounting strips with tapped holes (a) 6mm thick phjenolic laminated sheet/ bakelite sheet inside the window mounted on the existing mounting strips inside the flush door( b) S/F of Teriminalblock suitable for 16 sq. mm conductor4 Nos. & shorting links - 5 Nos. on DIN Chneels (c) Terminal suitable for 6 SWG GI Wire/ 1.5 sq. mm wire (d) 6Amp SPMCB 10 KA "C" Series - 1 No. i/c mounting on DIN Channel(Make : Bajaj/ Paruthi)
103Supply and laying of 4 X 16 sqmm PVC insulated and PVC sheathed /XLPE aluminium conductor armouredpower cable confirming to 1.1 KV Grade of following size direct in ground including excavation, sand crushing, protective covering, refilling the same etc., as required
104Supply and fixing of street light Pole Box of size 8" X 10" complete with all accessories i/C suitable clamps, suitable bakelite sheet, brass screws, washers and 1 Nos. SP MCB 10 amps capacity i/c making connection etc., as required at site.
105Supplying, Installation, testing and commissioning of 200 watts flood light fitting 5700 k pressured dia cast housing with IP65 protection high efficient 220-240V output emitter LED for better distribution with dimention and all accessories and suitable GI bracketetc. as required at site. (Philips/ Trilux ) Model BVP 184 LED 197NW FGWB 200W PSU
106S/I/T/C of 35 watts ruby decorative post top light fitting for 360 degree illumination 6500 k pressured die cast housing with IP65 protection high efficient 220V-40 V output emitter LED for better distribution with all accessories etc. as required at site (Havells/Wipro)
107S/F/testing and commissioning of LED fitting double box type fitting ( 2 x 18 watts )complete with all accessories having 2 nos Mas LED 18 watt tubes etc. on directly on ceiling or wall i/c connection with 1.5 sqmm FR PVC copper cond. cable etc. as reqd.( Model no. TMC 502 2 x T LED 22WP3242 ) ( Philips/Trilux )