noida metro rail corporation limited has published Tender For Maintenance Contract Of Fire Fighting System Installed At Ngn Depot, Staff Quarter And 21 Nos. Stations Of Ngn Corridor For 3 Years. Submission Date for this Tender is 03-06-2024. Fire Fighting Consumable Tenders in noida Uttar Pradesh. Bidders can get complete Tender details and download the document.
FileName | File Description | File Size |
6b2c5765-bfec-495b-a920-447a61be7951.html | Tender Notice | 0 KB |
BOQ_1595959.xls | Tender Document | 0 KB |
GCC.pdf | Tender Document | 0 KB |
RFP.pdf | Tender Document | 0 KB |
SHE.pdf | Tender Document | 0 KB |
Tendernotice_1.pdf | Tender Document | 0 KB |
Sl. No. | Item Description |
1 | Schedule A |
2 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, Gl bolts, nuts, washers etc. as required : |
3 | 200 mm |
4 | 150 mm |
5 | 100 mm |
6 | 80 mm |
7 | 65 mm |
8 | Supply, Fixing, Testing and commissioning of Butterfly valve PN 1.6 with bronze/gunmetal seat duly ISI marked cmplete with nut-bolts, washers, gasket confirming to IS:13095 of following size as required: |
9 | 200 mm |
10 | 150 mm dia |
11 | 100 mm dia |
12 | 80 mm |
13 | 65 mm |
14 | 50mm |
15 | Schedule B |
16 | Pressure gauge H GURU-0-20KG/SQCM,0-16KG/SQCM |
17 | Providing, Installation, Testing & Commissioning of INDFOS Pressure Switch IPS -100, Range : 0 To 7 Bar and Adjustable Differential : 0.6 To 6 Bar (for replacement of Pressure Switch installed with Fire Fighting pumps) |
18 | Providing, Installation, Testing & Commissioning of SWITZER DM, 0-10BAR |
19 | Providing fixing testing and commissioning of precharged air vessel (size 450mm dia & 1000 mm height or as per site conditions) for pressurisation of hydrant/sprinkler system complete with adequate pressure switches (as per design/requirement) with valves to operate sequences including 25 mm dia drain valve, air release valve with stop cock on the top, 25mm inlet with isolating valve duly painted from inside and outside with two coats of enamel paint over a coat of primer complete as required. (Vessel should be suitable for rated working pressure) |
20 | Providing and fixing wheel for oblique type single headed outlet hydrant valve, type "A" as per IS: 5290. |
21 | Providing and fixing cast iron body 80mm dia Non Rising sluice valve spindle type confirming to IS:14846, PN 1.6 with all respect nut, bolt washer, gasket etc. Kirloskar make or equivilent. As directed by engineer incharge. |
22 | Providing and fixing of S.S. shutt of nozzle 7-8 mm dia bore with serrated tail 25mm dia hose reel pipe with all necessary item like suitable clamp |
23 | Providing and Fixing of Bellow Pad(Pressure Retainer)including cutting, screwing, welding, etc. with forged steel butt welded fitting with flanges all respect nut, bolt washer, gasket etc, make Easy flex/ Resistoflex |
24 | 80 mm |
25 | 150 mm |
26 | 200 mm |
27 | Providing and fixing of stainless steel Hose cabinet of size 1500mm x 1850 mm x 440 mm and 2 mm thickness or as per site conditions. Glazed with 5.5mm clear glass Powder coated Stainless Steel shutter door as appropriate with universal locking arrangement withgrill. The rate is inclusive of fixing with fastener of required size, hinges, lock etc. All work carried out as per direction of Engineer in Charge. |
28 | Supplying and fixing of stainless steel hose cabinet of size 2100 mm x 900 mm x 450 mm made of 2 mm thickness or as per site conditions with 6mm thick glazed glass doors including necessary locking arrangement suitable to accommodate external hydrants, 2 nos 63mm dia synthetic hose pipe. The rate is inclusive of fixing with fastener of required size, hinges, lock etc. All work carried out as per direction of Engineer in Charge. |
29 | Supplying and fixing of stainless steel hose cabinet of size 2100 mm x 1200 x 450 mm made of 2 mm thickness or as per site conditions with 6mm thick glazed glass doors including necessary locking arrangement suitable to accommodate external hydrants, 2 nos 63mm dia synthetic hose pipe. The rate is inclusive of fixing with fastener of required size, hinges, lock etc. All work carried out as per direction of Engineer in Charge. |
30 | Supplying and fixing of stainless steel hose cabinet of size 2100 mm x 1150 x 450 mm made of 2 mm thickness or as per site conditions with 6mm thick glazed glass doors including necessary locking arrangement suitable to accommodate external hydrants, 2 nos 63mm dia synthetic hose pipe. The rate is inclusive of fixing with fastener of required size, hinges, lock etc. All work carried out as per direction of Engineer in Charge. |
31 | Lock replacement of fire hydrant door as per direction of Engineer in Charge.(key type) |
32 | Lock replacement of fire hydrant door as per direction of Engineer in Charge.(Aldrop type) |
33 | Lock replacement of fire hydrant door as per direction of Engineer in Charge.(barrol nuttype) |
34 | Dismantling the existing pipeline, providing and fixing jointing & testing of heavy class -C GI pipe IS:1239 marked in the underground with accessories like elbow flanged joints, reducers, Neoprene Gasket, Nut-Bolts, etc. Required of the following pipes as per IS: 10221 with 4mm factory tape(15% overlap) in soft soil at depth 1.5 mtr excluding demolishing, excavation, and rebuilding/providing of RCC, CC, bituminous road, all work to be completed as per direction of the engineer in charge. |
35 | 150mm |
36 | Dismantling the existing pipeline, providing and fixing jointing & testing of heavy class -C GI pipe IS:1239 marked in the existing pipeline including cutting, screwing, welding, etc. with forged steel butt welded fitting with joints, reducers, gasket, nut-bolts, required of the following pipes painted with one coat of primer & two coat of PO red enamel fixed in ceiling walls, columns for a height with hangers, support fasteners all work to be executed as per Direction of the engineer in charge including chasing of wall/column/ceiling, etc. all complete work. |
37 | 200 mm dia |
38 | 150 mm dia |
39 | 100 mm dia |
40 | 80 mm dia |
41 | 50 mm dia |
42 | 25 mm dia |
43 | Providing and fixing of MS Blind plate of fire hydrant valve for plug the hydrant point. |
44 | 250 mm dia |
45 | 200 mm dia |
46 | 150 mm dia |
47 | 100 mm dia |
48 | Providing and Fixing of Rubber Bidding for Glass of fire hydrant box door. |
49 | Providingand fixing of landing valve hydrants of Type-A, confirming IS: 5290 dia stainless steels instantneous type single headed outlet with blank cap and chain complete with instantneous sprink lock type S.S. Female coupling of 63mm dia for connecting hose pipe ISI marked |
50 | Providing and fixing of 63mm of dia 15 mtr long rubberized fibre lines hose including stainless steel male female instantneous type 63mm , machine wound with copper wire complete in all respect hose to IS:636 type-A and coupling to IS:903 with ISI marked |
51 | Providing and fixing of 38mm of dia 15 mtr long rubberized fibre lines hose including stainless steel male female instantneous type 63mm, machine wound with copper wire complete in all respect hose to IS:636 type-A and coupling to IS:903 with ISI marked |
52 | Providing & fixing standard shortly size stainless steel branch pipe with 63mm dia inlet instantneous male coupling and thread outlet with 15 mm bore hexagonal base nozzle with IS:903 ISI marked |
53 | Providing & Fixing of 150 mm dia four way fire brigade inlet connection consisting of four nos. 63 mm instantneous type male coupling with built in check valves and shall protected with cap secured with chain, 150mm dia flanged outlet complete with nut-bolt and rubber insertion as per IS:904 |
54 | Providing and fixing100mm dia female threaded coupling fire brigade confirming to IS:903 and duly ISI marked |
55 | Providing and fixing wall mountining swinge type hose reel drum for housing 25mm dia and 45mtr hose reel tube, confirming to IS:884 and duly ISI marked |
56 | Providing and fixing thermo plastic synthetic hose reel tube for 45 mtr length confirming IS:12585 type-II |
57 | providing and fixing of gland Nut of Hydrant, make Omex/Superex/ Newage/ Getech/ Safeguard/ Padmini/Exflame/Fire Guard |
58 | Providing and fixing of Gland Bush of Hydrant, make Omex/Superex/ Newage/ Getech/ Safeguard/ Padmini/Exflame/Fire Guard |
59 | Painting of Fire hydrant line with synthetic enamel paint of PO Red color two coats as per direction of Engineer-in-Charge. |
60 | 200 mm dia |
61 | 150 mm dia |
62 | 100 mm dia |
63 | 80 mm dia |
64 | 65 mm dia |
65 | 50 mm dia |
66 | 25 mm dia |
67 | Providing and fixing of stainless steel Female adaptor size 65mm on Fire Hydrants, make Omex/Superex/ Newage/ Getech/ Safeguard/ Padmini/Exflame/Fire Guard |
68 | Providing and Fixing of Female adaptor rubber washer of required size in fire hydrant. |
69 | Providing and fixing PVC blank cap with chain for Hydrant |
70 | Providing and fixing of Glass of fire hydrant box door of5mm thickness,710*480 sqmm or as per site conditions |
71 | Providing and fixing of Glass of the fire hydrant box door of5mm thickness, 600*340 sqmm or as per site conditions |
72 | Providing and fixing of Glass of the fire hydrant box door of5mm thickness, 840*360 sqmm or as per site conditions |
73 | Providing and fixing of Glass of MCP of3mm thickness |
74 | Providing and fixing G.I. Union in existing G.I. pipe line, ---------------wherever required |
75 | 25 mm nominal bore |
76 | 40 mm nominal bore |
77 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, 3/8"", PN25 or as per site conditions |
78 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, 1/2"", PN25 or as per site conditions |
79 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, 15 mm, PN25or as per site conditions |
80 | Providing and fixing gun metal gate valve with C.I. wheel of quality (screwed end)approved; |
81 | 25 mm nominal bore |
82 | Painting of Fire hydrant boxes and FHC component with synthetic enamle paint of PO Red color two coat as per direction of Engineer-in-Charge. |
83 | providing and fixing of single acting Air release valve, 25 mm with all necessary connection |
84 | Attending water leakages in high pressure fire fighting, Plumbing by replacement of Neuprin gaskets etc as required at site.(per location) |
85 | Attending water leakages in high pressure fire fighting, Plumbing by welding complete etc as required at site.(per location) |
86 | Providing and laying in position cement concrete of specified grade -All work upto plinth level 1:3:6 |
87 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size). |
88 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Mild steel and Medium Tensile steel bars |
89 | Demolishing cement concrete manually / by mechanical means includingdisposal of material within 50mtr lead as per direction of engineer in charge 1:3:6 or richer mix |
90 | Digging & refixing around the fire fighting underground pipe to attend fault complete etc as required. |
91 | Providing and fixing support to existing fire pipe using U clamp/bolt, anchor etc for different size of pipes complete etc as required. |
92 | Supply of UL listed Pendant / Upright type Sprinkler Head rated at 68 degree centigrade |
93 | Supply of sprinkler drain with 25 mm dia ball valve. |
94 | PORTABLE FIRE EXTINGUISHERS for E&M |
95 | Refiling and weight verification of Fire Extinguishers as described below: |
96 | Carbon dioxide 4.5 kg capacityextinguisher |
97 | Mechanical foam type 9.0 liter capacity fire extinguisher |
98 | ABC Dry powder type- 4 Kg |
99 | ABC Dry powder stored pressure fire extinguisher - 6 Kg |
100 | ABC Dry powder stored pressure fire extinguisher - 9 Kg |
101 | Co2 gas type trolley mounted fire extinguisher of capacity 22.5 kg |
102 | Trolley mounted foam type fire extinguisher of capacity 50 liters |
103 | Supply and fixing of cartridge for water type fire extinguishers of Capacity 9 liter |
104 | Hydraulic Pressure testing (HPT) of Fire Extinguishers |
105 | Water type (stored pressure)- 9 litre |
106 | Mechanical foam Type (gas cartridge) - 9 litre |
107 | Carbon dioxide type - 4.5 kg |
108 | Carbon dioxide type -22.5 kg |
109 | ABC Dry powder type- 4 Kg |
110 | ABC Dry powder stored pressure fire extinguisher - 6 Kg |
111 | ABC Dry powder stored pressure fire extinguisher - 9 Kg |
112 | Trolley mounted foam type fire extinguisher of capacity 50 liters |
113 | Supply of following miscellaneous accessories of all extinguishers |
114 | CO2type 4.5 kg |
115 | WATER TYPE 9 LITRE |
116 | Mechanical foam type 9 litre |
117 | ABC Dry powder type 4 Kg |
118 | ABC Dry powder stored pressure fire extinguisher - 6 Kg |
119 | ABC Dry powder stored pressure fire extinguisher - 9 Kg |
120 | Trolley mounted foam type fire extinguisher of capacity 50 liters |
121 | CO2 type 22.5KG trolley mounted |
122 | CO2type 4.5 kg |
123 | WATER TYPE 9 LITRE |
124 | Mechanical foam type 9 litre |
125 | ABC Dry powder type 4 Kg |
126 | ABC Dry powder stored pressure fire extinguisher - 6 Kg |
127 | ABC Dry powder stored pressure fire extinguisher - 9 Kg |
128 | Trolley mounted foam type fire extinguisher of capacity 50 liters |
129 | CO2 type 22.5KG trolley mounted |
130 | CO2type 4.5 kg |
131 | WATER TYPE 9 LITRE |
132 | Mechanical foam type 9 litre |
133 | ABC Dry powder type 4 Kg |
134 | ABC Dry powder stored pressure fire extinguisher - 6 Kg |
135 | ABC Dry powder stored pressure fire extinguisher - 9 Kg |
136 | Trolley mounted foam type fire extinguisher of capacity 50 liters |
137 | CO2 type 22.5KG trolley mounted |
138 | CO2type 4.5 kg |
139 | WATER TYPE 9 LITRE |
140 | Mechanical foam type 9 litre |
141 | ABC Dry powder type 4 Kg |
142 | ABC Dry powder stored pressure fire extinguisher - 6 Kg |
143 | ABC Dry powder stored pressure fire extinguisher - 9 Kg |
144 | Trolley mounted foam type fire extinguisher of capacity 50 liters |
145 | CO2 type 22.5KG trolley mounted |
146 | Stickers/labels for revalidation for all extinguishers |
147 | Painting/coloring for all types of extinguishers |
148 | Supply and fixing of fire extinguisher ABC Dry powder type 4 Kg capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
149 | Supply and fixing of fire extinguisher ABC Dry powder type 6 Kg capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and brackets, along with supply of all materials and labour for proper completion of work. |
150 | Supply and fixing of fire extinguisher ABC Dry powder type 9 Kg capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and brackets, along with supply of all materials and labour for proper completion of work. |
151 | Supply and fixing of fire extinguisher Water type (stored pressure)- 9 litre capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
152 | Supply and fixing of fire extinguisher Mechanical foam Type (gas cartridge) - 9 litre capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall brackets, along with supply of all materials and labour for proper completion of work. |
153 | Supply and fixing of CO2 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall brackets, along with supply of all materials and labourfor proper completion of work. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail