Tender For Repair/Maintenance Of Street/Security Lights,High Mast Lights,Bollards And Other Allied Works At Af Stn Memaura, Lucknow-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair/Maintenance Of Street/Security Lights,High Mast Lights,Bollards And Other Allied Works At Af Stn Memaura. Submission Date for this Tender is 25-05-2024. Traffic Delineators Tenders in Lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43307550
Tender For Repair/Maintenance Of Street/Security Lights,High Mast Lights,Bollards And Other Allied Works At Af Stn Memaura
Open Tender
Indian
Uttar Pradesh
Lucknow
25-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Repair/Maintenance Of Street/Security Lights,High Mast Lights,Bollards And Other Allied Works At Af Stn Memaura

Key Value

Document Fees
INR 500 /-
EMD
INR 19000.0 /-
Tender Value
INR 9.50 Lakhs /-

Attachment

FileName File Description File Size
e3428982-26da-40e0-bd94-b627170a71f3.html Tender Notice 0 KB
BOQ_730303.xls Tender Document 0 KB
tender8336.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: Repair/maint of street/security lights, high mast lights, bollards and other allied works at AFS Memaura
Sl. No. Item Description
1Dismantling and taking down carefully defective/non fuctional LED street light fittings from its existing position and refixing the same after repairing/replacement of unserviceable spare parts including re-assembling and testing complete all as specified and directed. (Note : Spare parts/component of street light and other light fitting shall be measured and paid seprately under respective items.)
2Supply and fix in replacement LED street light fittings 35 watt complete fitting having pressure dia cast aluminium housing with heat resistant toughened glass & IP 65 protection complete all as specified and directed.
3Supply and fix in replacement LED street light fittings 60 watt complete fitting having pressure dia cast aluminium housing with heat resistant toughened glass & IP 65 protection complete all as specified and directed.
4Supply and fix in replacement LED flood light 50 watt 230 V, Warm White, AC outdoor type with thermal management in multiple optics and equipped with IP66 ,protection, with impact and corrosion resistant complete with driver and lamp.
5Supply and fix in replacement LED flood light 150 watt 230 V, AC outdoor type with thermal management in multiple optics and equipped with IP66 ,protection, with impact and corrosion resistant complete with driver and lamp.
6Supply and fix in replacement LED flood light 250 watt 230 V, AC outdoor type with thermal management in multiple optics and equipped with IP66 ,protection, with impact and corrosion resistant complete with driver and lamp.
7Supply and fix in replacement aluminiumround Decorative LED post top lantern 40 watt with transparent diffuser, 230 volts AC outdoor type, IP 65 with impact and corrosion resistant, pole mounted complete with driver and lamp complete.
8Supply and fixing in replacement LED strip lights, having IP65 rating, warm white (3000K) colour temp, complete all as specified and directed.
9S & F in replacement of 6W decorative LED extruded aluminium minibollard light, warm white, rectangular shape with integrated driveretc including cable connections complete all as specified and as directed.
10Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m in depth and getting out soft /loose soil complete all as specified and as directed for laying of under ground cable/pipe etc. complete all as specified and as directed
11Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc 25 cm thick in soft/loose soil,complete,all as specified and directed.
12Removing surplus excavated material to a distance not exc 50 meter and depositing where directed at level not exc 1.5m above the starting point,complete,all as specified and directed.
13Material and labour for providing sand cushioning with dry fine sand including filling, spreading, levelling in layers in cable trench with approved quality of sand for protection of under ground cable complete all as specified and directed.
14Supplying & laying burnt clay bricks, sub class "B", laid in trenches over cable protection complete all as specified and directed.
15Taking up/down old U/S 6/10/16 sqmm 2/4 core XLPE insulated & armoured Al cable all as specified and directed.
16Supply, laying and testing ofLT cable 1100 volt grade XLPE insulatedunderground electric cable PVC bedded andsheathedsteel wire/strip armoured aluminum stranded conductor of size 6 Sq mm 2 core complete all as specified and directed.
17All as per item No - 16 but size 10 Sqmm 2 core
18All as per item No - 16but size 10 Sqmm4 core
19All as per item No - 16but size 16 Sqmm4 core
20Boring holeshorizontally under road without damaging the surface of road ( minimum 1.0 Metre below the road surface with the help of GI tubing not exc 80 mm bore(dia) for passing UG cable, complete all as specified and as directed. NOTE : - GI Pipe laid will be measured and paid separately under respective item
21M&L for 40mm bore GI pipe light grade for cable protection ISI marked with all fittings and fixedcomplete to walls and ceilings or laid in floors complete all as specified and directed.
22M&L for 25mm bore GI pipe light grade for cable protection ISI marked with all fittings and fixedcomplete to walls and ceilings or laid in floors complete all as specified and directed.
23S&F in replacement street light bracket made out of GI tubing 40mm bore medium grade n.exc 1.5 metre long bent to shape as directed including suitable MS clamp of FI 50x6mm with MS bolts nuts and washer fixed to steel tubular pole/PCC pole duly painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
24S & F in replacement DK Thermoplastic cable junction boxes IP 65 with metric knockouts for cable entry, weather proof for outdoor installationand including glands and with 4 terminals for terminating oneincoming and outgoingUG cable of size 10/16 sqmm 3.5/4 core and fixed to the PCC/Steel Poles by means of suitable size of clamps with nut and boltsand incl provn for fixing 01 Nos of single pole MCB SP 0.5-3 Amp "C" series inside the box and all specifiedand directed.
25Supply and fix in replacement LED driver sutable for 35 wattto 90 watt LED fittings includingconnection all as specified and directed.
26Supply and fix in replacement LED driver sutable for 120/150 watt LED fittings includingconnection all as specified and directed.
27M&L painting of LT steel tubular pole with one coat of aluminium paint including brackets and synthetic enamel painting of Air Force blue (0.75M above foundation) and 02 Nos alternate layer of red & yellow colour self adhesive reflectic tape of 100MM width & writing pole number on black background with white letteringafter scraping /cleaning well the existingrustedsurface complete all as specified and directed.
28M&L painting of LT octagonal pole bottom portion with two coat of Air Force blue (0.75M above foundation) over a coat of red oxide primer & 02 Nos alternate layer of red & yellow colour self adhesivereflectic tape of 100MM width& writing pole number on black background with white letteringafter cleaning well the existingsurface complete all as specified and directed.
29S & F MCB single pole 240 volts, "C" curve of rating 0.5 amps, with rupturing capacity 10 KA,including providing thimble for out going cables complete all as specified and directed.
30S & F MCB TPN 415 volts, "C" curve of rating 32 amps, with rupturing capacity 10 KA,including providing thimble for out going cables complete all as specified and directed.
31S & F in replacement Contactor of rating 40 Amps 440 V, triple pole with auxiliary contacts for AC circuit, DIN mounting confirming to IS/IEC 60947-4-1 complete all as specified and directed. Make : L&T /BCH/ Siemens/Schneider.
32S & F Analog type timer, 220 V AC, curent rating 16 Amps, ON-OFF-ON type, Daily programmable, DIN rail mounting and testing on completion complete all as specified and directed. Make : Havells/L&T /ABB or equivalent.
33Material and labour in replacement 1.5 sqmm three core copper PVC insulated sheathed cable drawing into inside the Pole / bracket of street light including making hole of 15 mm dia on bottom & topcomplete all as specified and directed.
34M&L for earthing complete with galvanized steelpipe electrode 40 mm bore, medium grade 2.50 meters length,buried in ground vertically to a depth n.less than 3.75 mtr below normal ground leveland connected with GI earthing wire 4 mm dia by means of bolts, nuts and washers made of galavanised iron and steel earth wire protected by 15 mm bore light grade GI pipe incl PCC work as per sketch No - 2 of SSR Part -I (2009) pit cover slab of size 300x300x50 mm with handle as shown in drawing funnel, wire mesh20 mm dia GI pipe medium grade for watering, charcoal and slat in alternate layers incl necessary earth work and excavation in soft/loosesoil and removal etc incl testing complete all as specified and directed including tesing on completion.
35Supply and Installation in replacement of LED Aviation obstruction light aluminium alloy housing, red coloured poly carbonate dome and accessories including fixing of 3 m long GI tubing 50 mm dia complete all as specified and directed. Make BAJAJ/ Havells or equivalent.
36Excavation in post holes (or similar holes ) each not exceeding 0.5 CUM, getting out, returning, filling in and ramming earth or borken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
37M & L for PCC (1:3:6) type C2 (using 40mm graded crusehd stone aggregate ) as in foundation of pole including necessary form work complete all as specified and directed.
38M & L Brick work with sub class "B" bricks straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:4 all as specified and as directed.
39M & L for 15 mm thick rendering in cementmorter (1:4) on fair face of brick or concrete surface finished even and fair all as specified and as directed.
40S & F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framedbalusters; walk ways; railings; framework of gate lights and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and as directed.