Tender For Certain Repair To B/R Misc Works In Otm And Md Accommodation At Zone-I And Ii At Umroi Mil Stn Under Ge Umroi, umroi-Meghalaya

Military Engineer Services-MES has published Tender For Certain Repair To B/R Misc Works In Otm And Md Accommodation At Zone-I And Ii At Umroi Mil Stn Under Ge Umroi. Submission Date for this Tender is 24-05-2024. Building Work Tenders in umroi Meghalaya. Bidders can get complete Tender details and download the document.




Tender Notice

43298561
Corrigendum : Tender For Certain Repair To B/R Misc Works In Otm And Md Accommodation At Zone-I And Ii At Umroi Mil Stn Under Ge Umroi
Open Tender
Indian
Meghalaya
umroi
24-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Certain Repair To B / R Misc Works In Otm And Md Accommodation At Zone-I And Ii At Umroi Mil Stn Under Ge Umroi

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-May-2024 CORRIGENDUM BOQ 24-05-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 72000.0 /-
Tender Value
INR 36 Lakhs /-

Attachment

FileName File Description File Size
0cbc7327-b04b-455d-95e9-f25f6bc7c95f.html Tender Notice 0 KB
8820TENDERDOCUS.pdf Tender Document 0 KB
BOQ_730186.xls Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: CERTAIN REPAIR TO B/R MISC WORKS IN OTM AND MD ACCN AT ZONE-I AND II AT UMROI MIL STN UNDER GE UMROI
Sl. No. Item Description
1Taking down door frame or Chowkhats or frames exc. 1.5 sqm but n.exc 4.0 sqm each(without taking off shutter from frame), complete all as specified & directed.
2Taking down door frame or Chowkhats or frames n exc. 1.5 sqm each(without taking off shutter from frame), complete all as specified & directed.
3Dismantling floor,hearth or wall tiling including cement mortar bedding ( but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr-in-Charge.
4S&F sheet glass ordinary quality 4mm thick glazing in square/ rectangle n,exc 0.50 sqm each pane with oil putty or aluminium beads fixed to steel etc, complete all as specified & directed.
5S&F powder coated (minium thickness 50 micron) aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc, complete all as specified & directed.
6S&F powder coated aluminium door and window shutters, aluminium section weighing 0.75 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc, complete all as specified & directed.
7Supply and fix aluminium anodised (powder coated) Ventilator frame withside hung Shutter(bottom Half Portion Fixedand top half portion openable shutte with 4.0mm thick frosted glass) including all necessary joining cleats, hold fast, rubber gasket, snap beading and locking arrangements,Hinges,Tower bolt fixed with screws to wall etc. complete andglazing with and including 4 mm thick frosted glass to aluminium frame work using rubber gasket and including stainless steel wire cloth of 0.36 mm dia & average width of aperture 1.40mm with staple or suitable fillets wire mesh fitted with screws and washers etc including aluminium grill of thickness 5mm and opening not exceeding 75mmx75mm etc completee with the following section of frame and shutter (A) Sections for shutter - section 41 x 20 x 1.50 mm thick(B) Section for frame63.5 X 38.1X 1.53mm thick, complete all as specified & directed. Note:- (a) Quoted rates are deemedinclusive of taking down ventilator of any size and any description and making good to match the existing surface as per existing sch of finishes.
8Supply and fix aluminium anodised (powder coated) Three track sliding window frame with shutters with ( 2 nos glazed and one wire gauzed shutter)including all necessary joining cleats, hold fast, rubber gasket, snap beading and locking arrangements fixed with screws to wall etc. complete andglazing with and including 5 mm thick tinted glass to aluminium frame work using rubber gasket and including stainless steel wire cloth of 0.36 mm dia & average width of aperture 1.40mm with staple or suitable fillets wire mesh fitted with screws and washers etc including aluminium grill of thickness 5mm and opening not exceeding 75mmx75mm etc completee with the following section of frame and shutter (A) Sections for shutter (i) "H" section 39 x 20 x 1.50 mm thick (ii) "Interlock" section 39 x 20 x 1.50 mm thick (iii) "Edge & Bottom" section 41 x 20 x 1.50 mm thick(B) Section for frame (i) Top & Sides 92 X 29.50X 1.50mm thick(ii) Bottom 92 X 29.70 X 1.50mm thick, complete all as specified and directed. Note:- (a) Quoted rates are deemed inclusive of taking down ventilator of any size and any description and making good to match the existing surface as per existing sch of finishes.
9S&F prelaminated particle board of 12mm thick, exterior grade, prelaminated one side with decorative choice lamination & otherside balancing white lamination, fixed with screws to timber frame work, complete all as specified & directed.
10M&L for vitrified ceramic tiles 10 mm thick (square/ rectangular) light shade polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and inluding 15 mm thick screed bed in Cement mortar (1:6), complete all as specified and as directed.
11M&L for Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and inluding 15 mm thick screed bed in Cement mortar (1:6), complete all as specified and as directed.
12Demolition of RCC with concrete cutter machine of any description and in any position not otherwise specifically providedfor including taking out and seperating old reinforcement andremoval of debries to a distance not exc 50m as directed by Engineer in charge and making site clean complete all as specified and directed. Note:- Rate deemed to be included in quoted rate for during demolitionof RCC water tank the temporary arrangment of water connection using 500 liter pvc water tank shall be provided by the contractor till completion of work
13Material and labour for taking down of existing roof treatment from roof and terrace, roughening surface of old concrete roof by picking, sweeping clean and washing down with water to remove dust, etc and applying roof treatment with the following steps and specifications:- a) Applying crack seal compound of same manufacture of waterproof to fill all cracks of observed on the roof. b) Applying cement slurry over concrete surfaces @3kg/sqm. c) Rendering 15mm thick in cement mortar (1:4) mixed with water proofing compound as per manufactures’ instruction(not less than 3% by weight of cement) on cleaned concrete surfaces of roof and finishing the surfaces fair and even including curing the plastered surfaces for 7 days by ponding of water over the roof, (leveling course). d) Applying evenly one coat of primer coating (diluted with water in the ratio specified by Manufacturers) (min @100-110Sq Ft per liter (diluted quantity)) on the cleaned plastered surfaces. The surface shall be left for air dry for minimum period of 2-3 Hrs. e)Applying evenly one coat of elastomeric water proof coat in one direction (as specified by Manufacturers)(min@ 0.9-1.0 sqm per ltrs) and allow to air dry for 4-6 hrs before applying second coat in other direction perpendicular to the first one (as specified by Manufacturers) (min @0.9-1.0 sqm per ltrs. The total thickness of two coats shall be 0.5 to 0.6 mm. f) The whole system shall be left for air cure for min Seven days (without any movement). Make : - Dr Fixit Newcoat Ezee or Berger Home Shield PU RoofKoat or Asian Paints Smartcare Damp Proof or as equivalent approved by GE. Note : - (i) The waterproofing shall be carried out in the last stage of execution to avoid any damages during the execution. (ii) Payment against this item shall not be allowed till completion of all the stages of work for any slab. (iii) The work shall be executed through well-trained applicators as per manufacturer’s instructions after obtaining written approval from the GE
14S&F 500ltrs rotationalmoulded polyethylene white colour square type water storage tanks (ISI marked) with closed top hoisted and fixed in position all as specified in SSR Part-I, complete all as specified and as directed.
15Supply & Fixing 20 mm dia ball brassvalve high pressure with polythene float and fly nut complete scrwed for iron pipe or brass ferrule, complete all as specified and as directed.
16Taking up or down steel tubing and conncection 20 mm bore, complete all as specified and as directed.
17Supply and fixing 20 mm bore tubes medium grade galvanized with all fittings and fixed complete to walls and ceiling or laid in floor bore, complete all as specified and directed.
18M&L for preparing old external surfaces of existing treatment by washing, rubbing down and stopping of weather proof paint and painted surfaces of external wall and applying one coat of antifungal paint, complete all as specified and as directed.
19M&L for preparing old painted surfaces by washing, rubbing down and stopping of distempered and painted surfaces and applying a coat of distemper oil emulsion on surfaces of walls, complete all as specified and as directed.
20Taking down cement or cement lime plaster on brick or stone walls, etc.including raking out joints, hacking for key, scrubbing down with water, etc, complete all as specified and as directed.
21M&L for rendering 15mm thick in cement mortar (1:4) external surfaces on fair faces of brick work or concrete surfaces, complete all as specified and as directed.
22M&L for rendering 15mm thick in cement mortar (1:6) internal surfaces on other than fair faces of brick work or one side of lathing surfaces, complete all as specified and as directed.
23M&L for preparing surfaces of newly plastered surfaces on walls and applying two coat of distemper oil emulsion including 1.5mm thick internal wall putty with alkali resistant primer, complete all as specified and directed.
24M&L for preparing surfaces of newly plasteredon wallsand applying two coat of acrylic smooth exterior paint including 1.5mm thick external wall puty oil emulsion, complete all as specified and directed.
25Demolition of cement concrete above ground floor and pavings exc 15 cm thickness (below or above ground level ) unreinforced, complete all as specified and as directed.
26M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in plinth protection, complete all as specified and directed.
27M&L for cement concrete (1:3:6),type C2 (using 40mm graded stone aggregate) in surface channels and drains, complete all as specified and directed.
28Taking up or down GI tubing 15 mm bore from wall/ceilings including all fittings segrated and stacking the pipe, complete all as specified and directed.
29S&F for CPVC pipes of 20 mm outer dia, SDR 11 and plain CPVC SDR 11 fittings on walls/ ceiling or laying in wall/ceiling or laying in floors, complete all as specified and directed.
30S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor overall cover plate length 150mm, complete all as specified and directed.
31Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including allquoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed.
32Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed.
33Dismantling of chain link fencing of any gauge & size exceeding 4kg/sqm, complete all as specified and directed.
34Excavation in post holes (or similar holes) each n.exc 05 cum getting out, returning. Filling in and ramming earth or broken rubble mixed with earth around in layers n.exc 25 cm, getting out in soft/loose soil, complete all as specified and directed.
35Material and labour for PCC (1:4:8) type D-2 using 40 mm graded stone aggregates as infoundations, filling and mass concrete, complete all as specified and directed.
36Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire, complete all as specified and directed.
37Supply only Chain link MS galvanisd fencing, any size or type, complete all as specified and directed.
38Material and labour for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 30cm long, complete all as specified and directed.
39M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm in width or girth, not otherwise described including priming with red oxide and applying two coat of synthetic enamel paint, complete all as specified and directed.
40S&F in repair Galvanised 2 strand, steel barbedwire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured), complete all as specified and directed.
41M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade incl 25mm thick sand cushioning and providing 50mm thick PCC (1:4:8) type D2 as in sub-base inclusive of dismantling stone slabs and demolition of PCC, complete all as specified and directed.
42Material and labour for pre-painted chequered cement concrete tileswith mixture of white and grey cement in equal proportions and no pigments 20 cm x 20 cm x25 mm thick, over and including 20 mm thick Screed of CM (1:6) and set jointed and pointed in neat cement slurry to be laid, complete all as specified and directed.
43M&L for Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ridge/ cladding to wall, fixed with self tapping screw in roofs including dismantlingof old u/s sheet, complete all as specified and directed.
44M&L for mild Steel work in tubular trusses Fe-410 including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 etc as in post, roof purlins rafter and connected items, complete allas specified and directed.
45S& F angle iron post in fencing and similar work shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165(Brackets over 10 kg each to be measured under "Structural Steel"), complete all as specified and directed.
46M&L for Pre-cast cement concrete block masonry Type C1Type C1(1:3:6) (using 20mm graded stone aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar (1:4), complete all as specified and directed.
47Material & labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over over newcomplete all as specified and as directed.
48Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided andremoval of debries to a distance not exc 50m as directed by Engineer in charge and making site clean complete all as specified and directed,
49M&L for 100mm thick PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in path/hardstanding, complete all as specified and directed.
50Schedule of Credit
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail