}

Tender For Roof Treatment To Certain Buildings At Camp Area, Pinto Park Area At Af Stn Palam Under Ge (Af) Palam, Delhi Cantt-10, palam-Delhi

Military Engineer Services-MES has published Tender For Roof Treatment To Certain Buildings At Camp Area, Pinto Park Area At Af Stn Palam Under Ge (Af) Palam, Delhi Cantt-10. Submission Date for this Tender is 24-05-2024. Building Work Tenders in palam Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

43297609
Tender For Roof Treatment To Certain Buildings At Camp Area, Pinto Park Area At Af Stn Palam Under Ge (Af) Palam, Delhi Cantt-10
Open Tender
Indian
Delhi
palam
24-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Roof Treatment To Certain Buildings At Camp Area, Pinto Park Area At Af Stn Palam Under Ge (Af) Palam, Delhi Cantt-10

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-

Attachment

FileName File Description File Size
87120d1d-2947-469b-ad42-eda92f18841f.html Tender Notice 0 KB
BOQ_729934.xls Tender Document 0 KB
T08TENDER.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work:ROOF TREATMENT TO CERTAIN BUILDINGS AT CAMP AREA, PINTO PARK AREA AT AF STN PALAM UNDER GE (AF) PALAM, DELHI CANTT-10
Sl. No. Item Description
1Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed.
2M&L for 15mm thick rendering in cement mortar (1:4) by using manufactured /washed stone yellow/grey sand for plaster on fair faces of brick or concrete surfaces on walls including finishing surface even and fair without using extra cement complete all as specified and as directed. Note for ser item No. 1.00 & 2.00:- The work shall be carried out upto four storey therefore necessary arrangment and scaffolding with all safety measures shall be deemed to be included in unit rates.
3M&L for 15mm thick rendering in cement mortar (1:6) by using manufactured /washed stone yellow/grey sand for plaster on fair faces of brick or concrete surfaces on walls including finishing surface even and smooth without using extra cement complete all as specified and as directed.
4M&L for 10mm thick rendering in cement mortar (1:4) by using manufactured /washed stone yellow/grey sand for plaster on fair faces of brick or concrete surfaces as in ceiling including finishing surface even and smooth without using extra cement complete all as specified and as directed.
5Dismantling of wall and ceiling and boards (Fibre, pulp, insulation etc.) or insulation board / slabs any thickness including cover fillets complete all as specified and as directed.
6S&F for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre includingHangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat (40 x 3)mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed.
7S&F for 6mm thick nonasbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specied and as directed.
8M&L in repair for guniting of RCC work as in coloum, beams, slabs, ceiling,chajjas,facia, landing, balconies etc by removing loose concrete including plaster, cleaning of surfaces with wire brushes and S&F welded steel wire mesh 50 mm x 50 mm with 3 mm dia steel wire and applying an epoxy resin concrete bonding agent treatment over the old concrete surface to bond with the new concrete with Nitobond EP of M/s Pidilite or its equivalent in Fosroc/Choksey (as per manufacurer"s instruction) to bond old and new concrete, guniting with minimum pressure of 2.5 Kg per Sqcm in two layers of total avg thickness 25 mm thick in cement mortor (1:2) using ordinary portland cement of 43 grade mixing with water proofing admixture polycrete @ 2% by weight of cement and after that applying 10 mm thick rendring in CM 1:4 over guniting surface complete all as specified and directed by Engr-in-Charge. Note :The following items shall be deemed to be included in quoted rate :- (a) Provn of required dia of TMT reinforcement bars and binding/welding with old bars (b)After placing the reinforcement all concrete surface shall be throughly scrubbed with brush, washed with water and allowed to dry for guniting/concreting/plastering (c) Work is to carried out in patches (d) Rate for scaffolding etc shall be deemed to be included in quoted rate (e) Guniting from Ground floor to four story building (f) Anti-corrosive protective coating for old reinforced bars (g) Finish the top surface of guniting even and fair with truly horizontal/vertical as directed by plastering.
9Takingdown of existingroof treatment as tarfelt,cement plaster, concrete padding etcof anydescription and thicknesson rooftopincluding flashing andjunctionof parapetincludingremoving the debrisfrom site to out ofMODland completeall as specified and as directed. Note :-The quoted rate shall be deemed to be inclusive of disconnecting the water tanks orsolar heater etc and re-fixing in the same in position after completing of roof treatment.
10Demolition of mud on roof of any thickness including plastering leaping (whether full thickness removed or only a part thereof) and removing debries from site to out of MoD land completeall as specified and as directed.
11Cleaningtop surfaces by brooming, wire brushing, removing grass, raking out joints to receiveplaster/screed bed and removing debris, grass etc from site to outside MoD land completeall as specified and as directed.
12M&L for 15mm thick screed bed in cement mortar (1:4) on concrete surface of roof, mixed with water proofing compound including finishing surface even and smooth without using extra cement in buildings upto 04 storey completeall as specified and as directed. Note:- Water proofing compound shall be measured & paid separately.
13Supply only liquidwater proofing compound completeall as specified and as directed.
14M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric not less than 150 gms/sqm laid on primed surface by torch application method over bituminous primer @ 0.30 Ltr/Sqmon newly plastered clean and dry roof surface including sealing of joint by torch application method completeall as specified and as directed. Note:- (a) The rate of necessary scaffolding wherever required shall be deemed to be included in the quoted rate of item.
15M&L for cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in roof padding, coving, gola, plateform for tank etc completeall as specified and as directed.
16M&L for factory made cement concrete tile 25cm x 25 cm x 20 mm thick, machine pressed, set and pointed in neat cement slurry as in roof/ terrace with grey cement and no pigment with and including over 15 mm thick screed bed in CM (1:4) complete all as specified and as directed.
17Demolition of brick masonry work, built in cement mortar of any description including removing the debris from site to outside MoD land completeall as specified and as directed.
18M&L for brick work with sub class "B" bricks straight or curved on plan exceeding 6m mean radius built in CM (1:4) completeall as specified and as directed.
19Dismantling of asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings completeall as specified and as directed.
20S&F for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/wall cladding and fixed with self tapping screws completeall as specified and as directed.
21S&F in repair PVC (SWR) pipes 110mm bore, single socketed, in any length with rubber ring joints fixed to walls or laid in floors etc complete all as specified and as directed.
22S&F in repair PVC (SWR) bend for 110mm in bore pipe jointing with solventcementcomplete all as specified and as directed.
23S&F in repair for stack clamp made of GI channel section with 10mm dia "U", bolt and nut fixed to wall to hold the vertical pipe of 100/110 mm dia completeall as specified and as directed.
24M&L in repair for welding thickness of Metal to be welded n.exc 6mm for railing, post, angle etc completeall as specified and as directed.
25S&F in replacement of 500 ltrs capacity rotational moulded polyethylene water storage tank three layers (cylindrical vertical with closed top) hoisted and fixed in position completeall as specified and as directed.
26S&F in replacement of 1000 ltrs capacity rotational moulded polyethylene water storage tank three layers (cylindrical vertical with closed top) hoisted and fixed in position completeall as specified and as directed.
27S&F 15mm bore galvanised steel water tubing‘medium grade’ with all ISI marked fittings and fixed on walls, ceiling or laid in floors including taking up or down old tubing complete all as specified and as directed.
28S&F for 20mm bore galvanised steel water tubing‘medium grade’ with all ISI marked fittings and fixed on walls, ceiling or laid in floors including taking up or down old tubing complete all as specified and as directed.
29Taking down existing water tank of capacity 500 to 1000 Ltr and refixing after necessary cleaning/water proofing treatment on roof surface including replacement of tank nipple etc completeall as specified and as directed.
30S&F in repair 20mm dia PTMT high pressure ball valve with aluminium epoxy coated rod and ball suitable to sustain water pressure (minimum weight 210 gm)complete all as specified and as directed.
31S&F in repairs 20 mm bore gun metal globe/gate valves with iron lever fixed, screwed both ends complete all asspecified and as directed.
32S&F in repair structural steel work as in beam and stanchion fixed in wall to support old slab by cutting and pining in existing walls, cut to shape, drilled & welding etc as necessary including gusset plates and conforming to Fe 410w (Grade E-250) including making good the surface with PCC (1:2:4) type B-1 completeall as specified and as directed.
33Repairs to old steel gate of size 2.50m wide, cutting into the size, erecting in position and welding etc including necessary painting complete all as specified and as directed.
34M&L for preparation of newly plastered surface of ceiling and applying three coats of white wash completeall as specified and as directed.
35M&L for preparation of newly plastered surface of walls and applying two coats of exterior emulsion paint 100% acrylic of approved colour and shadeover a coat of primer including necessary scaffolding upto 4th floor completeall as specified and as directed.
36M&L for preparation of newly plastered surface of walls and applying two coats of oil bound distemper of approved colour and shadeover a coat of primer including necessary scaffolding upto 4th floor completeall as specified and as directed.
37M&L for complete removal of existing treatment from old decorated plastered surfaces of walls byremoval of nails etc & filling cracks/hole with cement base putty, and applying two coats of oil bound distemper white or colouredby rollerover a coat of primer complete all as specified & directed by Engineer-in-Charge. Note:- Scafolding upto fourstorey bldg is include in unit rates.
38M&L for preparation of plastered or un plastered old decorated surfaces of wallsremoval of nails etc & filling cracks/hole by applyingcement base wall careputtyand applying two coats of exterior emulsion paint 100% acrylic of approved white or colouredcomplete all as specified & directed by Engineer-in-Charge. Note:- Scafolding upto fourstorey bldg is included in unit rates.
39M&L for preparation of plastered or un plastered old decorated surfaces of ceilingfilling cracks/hole by applyingcement base wall careputty as required (multipurpose mixer shall be used for uniform and proper mixing of putty) and applying one coat of oil emulsion distemper white or coloured complete all as specified & directed by Engineer-in-Charge.
40Excavation in post holes (or Similar Holes) not exc. 0.50 Cum each in soft/loose soil and getting out, returning, filling in and removing surplus spoil to a distance not exc. 50.00 m and make good the surfaces complete all as specified and as directed.
41Dismantling timber in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section from roof with all necessary safety measures and scafolding completeall as specified and as directed.
42M&L for cutting holes in brick walls in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar (1:3) or cement concrete (1:2:4) type B-1 as required of exc half brick but n exc one brick thick wall complete all as specified and as directed.
43Dismantling wrought iron or mild steel work of any description not otherwise provided for completeall as specified and as directed.
44M&L for mild steelstructural work as in stanchion and column including covering plate from steel sections or hollow sections conforming to Fe-410-0 or Fe-310-0 including all necessary welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated complete all as specified and as directed.
45M&L for mild steelstructural work as in rafter and purlins including covering plate from Steel Sections, hollow section of any description conforming to Fe-410-0 or Fe-310-0 including all necessary welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated complete all as specified and as directed.
46M&L for PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete, etc. for fixing posts complete all as specified and as directed.
47M&L for preparation of new steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of zinc chrome primer complete all as specified and as directed.
48M&L for 75mm thick PCC (1:3:6)type C2 (using 40mm graded stone aggregate) as in plinth protection and paving including finishing even and smooth without using extra cement complete all as specified ans as directed.
49S&F in repair PVC (SWR) pipes 150mm bore, single socketed, in any length with rubber ring joints fixed to walls or laid in floors etc complete all as specified and as directed.
50S&F in repair PVC (SWR) bend for 150mm in bore pipe jointing with solventcementcomplete all as specified and as directed.
51S&F in replacement of steel window box type made of ERW hollow sectionof size (130mm x 1.25mm) thick double rebated comprises gauged and glazed skeleton shutter ERW Section 50mmx20mm x 1mm thick double shutter with double leaf and arrangement for cooler opening including iron grill bar with 12mm square complete welded to frame with vertical mulion of size 130mmX65mm with 1.25mm thick ERW box type including cutting holes for hold fast (04 Nos each window) and making good dismantled portion with PCC (1:2:4) type B-1 including follwing fittings welded to frame / shutter :- (a) Hold fast of 150mm long of flat iran 25mmx3mm made to shape - 04 Nos each window. (b) MS Handle cold rolled of size 100mm long - 01 No per leaf. (c) MS tower bolt 100mm long -2 Nos per leaf. (d) Z- Section 20mmx25mm long stopper - 01 No per leaf. (e) MS pintel hinges of size 40mmx 25mm - 02 Nos per leaf including one coat of red oxide shop primer complete all as sepecifed and as directed. (Note :- The cost of stainless steel mosquito proof Wire meshand 4mm thick sheet glass shall be deemed to be included in unit rate)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail