Tender For Provision Of Accommodation For 44 Officers Alongwith Chs In Fire And Fury Officers Mess (Ph-I Of Ii Phases) Under Ge (I) (P) No. 1 Leh, Leh-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Provision Of Accommodation For 44 Officers Alongwith Chs In Fire And Fury Officers Mess (Ph-I Of Ii Phases) Under Ge (I) (P) No. 1 Leh. Submission Date for this Tender is 07-06-2024. Building Work Tenders in Leh Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

43297385
Corrigendum : Tender For Provision Of Accommodation For 44 Officers Alongwith Chs In Fire And Fury Officers Mess (Ph-I Of Ii Phases) Under Ge (I) (P) No. 1 Leh
Open Tender
Indian
Jammu And Kashmir
Leh
07-06-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Provision Of Accommodation For 44 Officers Alongwith Chs In Fire And Fury Officers Mess ( Ph-I Of Ii Phases ) Under Ge ( I ) ( P ) No. 1 Leh

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 06-May-2024 Ammendment to Tender Doucment Other 07-06-2024

Key Value

Document Fees
INR 3000 /-
EMD
INR 1210000.0 /-
Tender Value
INR 17.70 Crore /-

Attachment

FileName File Description File Size
212b7a3a-3c19-41fc-8958-01537bb35f27.html Tender Notice 0 KB
1Scanned44OffrsPhI.rar Tender Document 0 KB
1TenderPageNo01to32.pdf Tender Document 0 KB
2Scanned44OffrsPhI.rar Tender Document 0 KB
2SchAandPrepricedSchPage3_1.pdf Tender Document 0 KB
3AppendicesandSpecialCond_2.pdf Tender Document 0 KB
4ParticularSpecificationP_3.pdf Tender Document 0 KB
5ParticularSpecificationP_4.pdf Tender Document 0 KB
BOQ_730022.xls Tender Document 0 KB
TD1Scanned44OffrsPhI.rar Tender Document 0 KB
TD2Scanned44OffrsPhI.rar Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Nature of Work: PROVISION OF ACCOMMODATION FOR 44 OFFICERS ALONGWITH CHS IN FIRE AND FURY OFFICERS MESS (PH-I OF II PHASES) UNDER GE (I) (P) NO. 1 LEH
Sl. No. Item Description
1NOTE: Schedule ‘A’ Part - ItoPart -XIIare Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
2Total amount of Sch "A" Part - I (Buildings)
3Total amount of Sch "A" Part - II(Internal water supply)
4Total amount of Sch ‘A’ Part - III (Internal Electrification)
5Total amount of Sch ‘A’ Part - IV (Protective work)
6Total amount of Sch ‘A’ Part - V (Road)
7Total amount of Sch ‘A’ Part - VI (Path)
8Total amount of Sch ‘A’ Part - VII (Hardstanding and Pavement)
9Total amount of Sch ‘A’ Part - VIII (Area drainage)
10Total amount of Sch "A" Part - IX (Sewage Disposal)
11Total amount of Sch "A" Part - X(External Electric Supply)
12Total amount of Sch ‘A’ Part - XI (External Water Supply)
13Total amount of Sch ‘A’ Part - XII (Site clearance, Excavation and Earth work)
14SCH "A PART - XIII(Miscellaneous B/R and E/M works) Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 5 signifies this fact only
15Supplying and fix 13mm thick closed cell elastomeric nitrile insulationof density 30 to 40 Kg/m³suitable for 25mm dia pipe, covered with shrink wrap polythene sheet and fixing 28 SWG aluminiumsheet Cladding on insulated pipes with all fixing accessories and suitable size clamps @ 1m c/c to support pipe complete all as specified and directed.
16Supply and fixing LED bulb full dum 9 watt, retrofit all as specified and directed by Engr-in-charge complete. Make : Havells/Philips/CG
17S & F Double door three phase prewired distribution board vertical DB TPN 4 way with acrylic door made out of CRCA sheet 1.6 mm thick,phosphatised powder coated with copper Bus Bar 200 Amps, 415 V, IP43/ IK09, Earth Stud, Din Rail, Polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and includingMCCB4 pole 63 Amp rating rupturing capacity 16 KAcomplete all as specified and directed. Make - Legrand, Schneider,ABB and Siemens. Note :- MCBs are to be measured and paid for seperately.
18Supply & fix Multi-meter along with its enclosure,anti corrosive, dust proof, vermin and water proof, factory fabricated sheet metal wall mounted type Multi-meter box of size 1.0 mt x 0.5 mt x 0.25 mt made up of2mm thick CRCA sheet and including applyingtwo coats of synthetic enamel paint over one coat of red oxide zinc chrome primer of colour as approved by Engr-in-Charge suitable to accommodate and comprising of following :-
19(a) Wiring with PVC insulated unsheathed ISI marked 2 runs of 6 sqmm and single run of 6 sqmm as earth continuity, single core multi stranded copper conductor cable fixed to meter box with PVC tag connected in between incoming DB and electric meters etc complete all as specified and directed. (b) The metering box must have one 32 mm dia.incoming Cable entry hole with Gland provided at base and 4 Nos.16 mm dia. Outgoing cable entry holes with Gland. (c) The Multi-Meter Box should have 04 Nos. viewing windows made out of toughened glass of 5 mm thickness strategically placed so as to view the energy meter readings without opeing the door of the meter box and shall be fixed frominside
20of the cover ofMulti-meter box with stainless steel frame (glass holder) with suitable rubber gasket from inside the cover, so that it can withstand weather effect. (d) The system shall be A.C. Single phase 250 V or three phase, four wire, 433 V, 50 Hz with effectively grounded neutral. (e) The box must include all accessories like hinges, clamp, handles etc. (f)Multi-Meter box shall be so constructed so as to have roof tapering down for easy flow of rain water.
21(g)It should have locking arrangement by way of sealing and can be opened without breaking. Locking arrangement shall be such that a Lock with Key for locking of Multi-Meter Box to be provided. (h)The door in closed position should be overlapped on base such that direct entry of screwdriver, tool or film is not possible. (j)The contractor has to furnish a detailed dimensional drawing showing clearly the dimensions and material of Multi-Meter Box and its constructional features for approval of Engr-in-Charge prior to manufacturing the same. (k)Sign of danger shall be clearly and indelibly embossed (not printed) on the cover of the Multi-meter box.
22S & F LED buildingsecurity light, pressure die cast aluminum housing, 20/25 watts capacity, 240V, IP 65 class, with suitable in-built electronic driver and fixed on a bracket made out of 1.5 mtr long Medium grade GI pipe 40 mm dia bend to shape as directed fitted on wall at a height not less than 5 mtr from groundwith MS clamp, nuts and bolts and washers as required at siteincluding connecting luminarie to the nearest ceiling rose/ junction box with 1.5 sqmm PVC insulated 3 core wire complete all as specified and directed. NOTE - Cost of all minor spares and jobs required for fixing of light fixture on wall and all electrical connections are deemed to be included in the quoted rate.
23Supply and fixing TV Co-axial socket 1 module, complete all as specified and as directed.
24M & L for preparing bituminous surfaces of road by scratching spots, removing oils, greasy spots and marking 2mm thick centre lines, stop lines, dashes, arrows etc and the like n. exc 15 cm wide on roads, pavements using hot applied thermoplastic road marking paint of white or golden yellow colour as approved confirming to BS 3262-1989, applied with special applicator machine, mixed with radium glass beads @ 250gm/Sqm having reflective index of 1.5mm, 75% sptrical with indigenousto provide reflectivity and night vision (approximate temperature being 200 degree at the time of laying) having softening strength to withstand heavy load without deformation and having softening point 25 to 30 complete all as per manufacturers instruction complete all as specified and as directed.
25Supply, install, testing and commissioning of 250 KVA Servo controlled voltage stabilizer for automatic operation for unbalanced load, Oil cooled , indoor type and design for input variation between 260 to 480 Volt with output voltage stabilized at 415V ± 1% and speed of voltage correction of 20 volts per sec surge suppressor to be provided in stabilizer. Efficiency 98%, Lamination: CRGO, Protection: Over Voltage, Under Voltage and single phasing, Protection with indication: For input voltage High/low, by-pass arrangement with indication Metering: AC voltmeter and Ammeter with selector switch, Dimmerstat: motorised type, Dielectric Test: 1.5 KV RMS for 1 minute, Response time not exceed 20 milli second, Insulation Resistance: above 5M ohms at 500 VDC, Transformer oil conforming to IS-335, IEC 296, Stablizier Confirming to BIS 9815:1994 as per latest guideline)with 4 pole MCCB 320 Amps, 35 KA capacity Adjustable Thermal Magnetic Overload Setting of indoor type sheet metal enclosure silent operation with 1st filling of Transformer oil up to level.
26Labour for boring underground upto 100 mm bore for road crossing 3 mtr to 10 mtr not exceeding 1.5 mtr in depth for laying of electric cable and GI tubing in soft/loose soil complete all as specified.
27Supply, installation, commissioning and testing Junction boxes made of Lid PC and base is polystyrene Hensel reference : KG series suitable . Junction Boxes Size 217 x 253 x 115 mm in Grey RAL 7035 colour. Junction Box IP 65 Thermoplastic PS Polystyrene weatherproof Junction Box with multi level knockouts for cable glands in different sizes. The pre-moulded knockouts shall be available on top and bottom of the junction box to enable cable entries from both direction. The junction box shall have an optional cable entry at the bottom up Cable Size 25 Sq mm of the box via pre-moulded knockout to enable pole mounting option. Lid fasteners self closedwill be tool operated. it will be sealable with accessories. The junction box shall have elongated holes inside them for wall/pole mounting provision. The junction box with 4 Pole Terminal Strip and MCB SP 6 Amp 10 KA C Curve for LED light. In the event of formation of condensed water, the junction box shall have a minimum of two condensation knock-outs inside to ensure optimum safe performance.
28The junction box shall fulfill the following standards Weatherproof : Rainwater proof, temperature resistant. IEC 60670-22 : Particular requirements for connecting boxes and enclosures. IEC 60695 – 2 – 11 : Flame – retardant & Self-extinguishing. Glow Wire tested at minimum 750 deg C. IEC 60529 : IP 65 degree of protection. UV Resistant in accordance with IEC 61 439-1, Clause no 8.4.4 The Junction Box shall be with Suitable Glands 3 Noseach andchromium plated clamps, nut, bolts complete all as per manufacturer’s instructions. Make : Cat Part :- KG 9003 of Hensel/ Siemens/ GE Power/ Schneider/ L&T/ ABB. Manufacturer should submit routine test certificate of CJB/ PJB
29Supply, Installation, Testing and Commissioning of Automatic Power Factor Correction unit 400KVAR (output) @440 Volt Ac. The APFC unit shall comply with IEC 61439-1&2 & IEC 61921,IS-16636-2017. The degree of Protection of enclosure system of the APFC Panel shall be minimum IP-44 in accordance with IEC 60529. The APFC Panel shall be indoor type conforming to IS 13341:1992 and IS 13440:1993 floor mounted design, weather, dust and vermin proof suitable for weather conditions of Leh.
30The Equipment shall be comprising of the following:- (A) Insulated bus bar pan assembly made from Aluminum and rated of 1000 Amps Capacity. The short circuit withstand capacity shall be 50KA/1Sec(low) for the mains bus bar and the rated impulse withstand voltage shall be 6KV. (B) The incomer of the APFC Panel shall be a 630 Amp, MCCB ,3P,50KA TMD type With O/L & S/C protection, Ics=100%, MCCB shall have standard extended Rotary handle, spreaders, phase barrier, MCCB shall be of certified design conforming to IEC 60947-1,2 & 3 (C) Capacitor Units:- The Capacitor unit shall be metalized polypropylene film with Zn/ Al alloy. The capacitors shall be encapsulated in an aluminum can.
31The Capacitor unit shall have a rated voltage of 525V and shall have a maximum over current capacity of 2.5 In. The capacitor unit shall have a built in 3 phase over pressure protection and shall have discharge resistors (50V in 1 min) factory fitted and shall be tamper proof. Capacitor Tolerance -5%,+10%. Maximum permissible over voltage 1.1xUn,8 h every 24h. The capacitor unit shall be of Certified design confirming to IS-13340-1993,13341-1992 & IEC-60831-1&2.
32(D)Short circuit and Overload Protection :- Each stage of the APFC Panel shall have a suitably rated MCCB for short circuit and overload protection. The Over Current setting shall be adjustable & Breaking capacity Ics-36KA. The MCCB Shall be of certified design confirming to IEC 60947-1,2 &3. (E)PF Regulator /APFC Relay: Advance Range PF Regulator/micro-processor based APFC Relay having multiple steps with a LCD Display, Voltage Range 90V 550V,50/60Hz, CT Input:1A/5A with a built in RS485 communication port. The PF Regulator shall be of certified design confirming to IEC 61326.
33In addition to the PF Controller, the capacitor Bank, should also have an energy server which would collect, store and provides web access and visualization to various energy parameters and enable remote supervision from BMS to ensure Maximum utilization, enable remote commissioning/ trouble shooting of the capacitor bank, the energy server should monitor and display the following parameters remotely through a web page. Status of stages (open/close/faulty). Real time capacitance value of the connected stage. Initial capacitance value. Number of operation of stages (stage utilization/operation), energy parameter like: I.V.P.Q.S. operating PF, Target PF, Operating Temperature,
34Max Temperature, %THD V, % THD 1, Display of alarms, Trending curves of historical recorded data. (F)Stage Capacitor: The capacitor duty contactors shall be rated for 230 Volts AC and shall be 3 Pole type and shall be employed for switching ‘on’ and switching ‘off’ operations in capacitor banks. The contactor shall be AC-3 duty Type. The contactor shall be of certified design confirming to IEC 60947-1& 4-1. (G)Ventilating fans if required shall be used to dissipate the heat produce by the capacitor bank components like the capacitor units, reactors, contactors, breakers etc In addition to above the APFC Panel shall
35be provided withmains indicator in each phase, Capacitor On/Off Indicators, Start/Stop press button switches and auto/manual rotary switch for each stage capacitor Bank. Note :-The APFC Panel described as above complete in all respect as per specification enclosed, up to the entire satisfaction of engineer In Charge.To ensure safety, reliability and accountability of component co ordination, all the major capacitor bank components such as capacitor units, de tuning reactors, PF controllers, circuit breakers, contactors and the enclosure system called for in this specification should preferably be from a single manufacturer. The OEM shall preferably manufacturer PFC components and switchgear.
36Supply, installation, testing and commissioning LT panel of suitable size as per IE rule and latest IS, factory made dust and vermin proof outdoor type made out of 3.15 mm thick CRCA sheet including seperate compartment for each MCCB & for cable and busbar, mounted on frame of MS angle iron 40mmx40mmx6 mm with front and back openable door with lock & Key including necessary grouting and double coat powder coated of grey colour painting complete with following accessories.The degree
37of protection of panel shall be IP-54 including foundation all as specified and directed :- (Main LT Panel) INCOMING: (i) 4 pole ACB 1600 amps,with rupturing capacity 50 KA- 1 No (ii) Aluminium bus bar 3 phase 4 strip suitable for 3000 Amps current carrying capacity complete with post insulators and heat shrinkable sleeves- 01 No.
38OUTGOING : (i) 4 pole ACB 1600 amps, with rupturing capacity 50 KA- 02 No (for DG Set and spare) (ii) 4 pole MCCB 630 amps, with rupturing capacity 50 KA- 01 No (for APFC Panel) (iii) 4 pole MCCB 200 amps, with rupturing capacity 36 KA- 05 No (for SVR LT Panel 1) (iii) RYBindication lamp -01 No. (iv) Voltmeter digital type with range 0-500 Volts, -01 No. (v) Ammeter digital type with range 0-2000 Amp.
39Supply, installation, testing and commissioning LT panel of suitable size as per IE rule and latest IS, factory made dust and vermin proof outdoor type made out of 3.15 mm thick CRCA sheet including seperate compartment for each MCCB & for cable and busbar, mounted on frame of MS angle iron 40mmx40mmx6 mm with front and back openable door with lock & Key including necessary grouting and double coat powder coated of grey colour painting complete with following accessories.The degree of protection of panel shall be IP-54 including foundation all as specified and directed.:- (Sub LT Panel 1 @ 16 Accn )
40INCOMING: (i) 4 pole MCCB 200 Amps with rupuring capacity 36 KA ,- 01 No (ii) Aluminium bus bar 3 phase 4 strip suitable for 400 Amps current carrying capacitycomplete with post insulators and heat shrinkable sleeves- 01 No. OUTGOING (i) 4 pole MCCB 40 Amps with rupuring capacity 25 KA - 05 No (For officer block @ 04, spare) (ii)SPN 10 Amps -02 Nos (Garage 1 & 2 ) (iii) RYBindication lamp -01 No. (iv)Voltmeter digital type with range 0-500 Volts -01 No. (v) Ammeter digital type with range 0-300 Amp.
41Supply, installation, testing and commissioning LT panel of suitable size as per IE rule and latest IS, factory made dust and vermin proof outdoor type made out of 3.15 mm thick CRCA sheet including seperate compartment for each MCCB & for cable and busbar, mounted on frame of MS angle iron 40mmx40mmx6 mm with front and back openable door with lock & Key including necessary grouting and double coat powder coated of grey colour painting complete with following accessories.The degree of protection of panel shall be IP-54 including foundation all as specified and directed.:- (Sub LT Panel 2 @ 12 Accn)
42INCOMING: (i) 4 pole MCCB 160 Amps with rupuring capacity 36KA - 01 No (ii) Aluminium bus bar 3 phase 4 strip suitable for 250 Amps current carrying capacitycomplete with post insulators and heat shrinkable sleeves - 01 No. OUTGOING (i)4 pole MCCB 40 Amps with rupuring capacity 25 KA - 04 Nos (For officer block @ 03, spare) (ii) MCB SPN 10 Amps- 02 Nos (for Garrage 3 & 4) (iv) RYBindication lamp -01 No. (v)Voltmeter digital type with range 0-500 Volts -01 No. (vi) Ammeter digital type with range 0-300 Amp .
43Supply, install, test and commission factory made 100 Amps aluminium bus bar 6 way outdoor type CRCA sheet stell duly photophatized and opiwder coated with 7 tank process made enclousure three phase 50 Hz AC timer based wall/ pole mounted feeder piller box having degree of protection IP 54, door locking by panel lock and provision for pad lock, pre-wired ready to use, liberal termination space, louvers provided on both sides for proper heat dissipation, tesing and commissioning of the panel complete all as per direction and specifications of Engr-in-charge.
44Supply, installation, testing and commissioning of 11kV HT Outdoor Type, ICOG VCB Panel Board (VCB Type) for 11kv sub Station totally factory made Make of VCB, HT Panel, Meters, Relays, Vaccum Bottle-ABB, BHEL, Siemens, Schneider INCOMMER FEEDER : Supply of HT 12 KV, 3Phase 50Hz, totally metal clad withdraw able type Cacuum Circuit Breaker panel with Copper bus bar of suitable rating, horizontal isolation type VCB of capacity minimum 800 Amps rated current, Copper bus bar as per IEC 62271-100-200. The offered panels shall be tested for IAC level of min. 25kA/1s (ABB/BHEL/SIEMENS/ Schneider only) for better performance: (i) Mechanical life-30,000, (ii) Rated Current-10,000 & (iii) Rated Short Circuit Operations-100 Make : ABB (Unigear)/BHEL/Siemens (NX-Air)/Schneider (PIX). Panel and VCB parameters are as below:-
45(i) Rated Voltage level/PF withstand voltage/Impulse level : 12KV/ 70 kV/170 kVp for the altitude of upto 3500 mtr (Temperature range-35 degree C to 25 degree C) (ii) Continuous current rating : minimum 630A (iii) Short circuit withstand current: minimum 25KA for 3sec. (iv) One no. minimum 800 Amps horizontal draw out type vacuum circuit breaker in 12KV metal clad floor mounting panel complete with following:- (a) Manually & Motor operated(230V,AC,50Hz) spring charged type, manually and electrically open (electrical – 24 VDC) operation type, incorporatingmechanical as well as electrical ON/OFF indication "OFF" push button,
46test/service position limit switches, with minimum 6NO+6NC breaker auxiliary contacts in service position. (b) Epoxy cast wound current transformer (CT),12KV of rati 200-100 /5+5A, 5P10/0.5, 15 VA burden with metering and protection core including necessary control wiring (c) Voltage transformer with three nos. 1 phase, 3 limbs connected in star, dual class, 11 KV/V3/110V/V3,Cl. 1.0/0.5, 50 VA with draw able type with automatic safety shutters100VA burden with primary & secondary fuses.(Confirming related IS specifications).
47(A) Protection arrangements for the breaker shall comprise of the following: i) U/V, O/V, E/F, O/C, TCS with IEC 103 protocol for communication & drawout type- Numerical Type Siemens A1(7SJ62)/ ABB (REF615)/ Schneider (P3U20) compatible its RS 485 port for SCADA system (ii) Complete with Master Trip/ Anti pumping relay. All the Relays shall belong to a common platform and shall be of single make with Electromechanical Relays in Draw-out casing (B) The following meters, indications and accessories are to be provided with the panel : (i) Digital Voltmeter range 0-12KV with necessary voltmeter with built in selector switch & suitable for 110V AC 96X96 sq mm dial with shrouded terminal.
48(ii) Digital Ammeter range of applicable range with necessary ammeter with built in selector switch dual graduated scale 96X96 sq mm dial with shrouded terminal. (iii) Multi-Function meter PM8000 (iv) Necessary DC supply, healthy indication lamp & switch. (v) Control: (a)TNC (Trip, Neutral & Close) breaker control switch with indicating arrangement, (b) Local/Remote selector switch for breaker open/close operations. (vi) Including G.I Sheet shed with column pipe of size 50 mm dia. height 3 mtr, length 3 mtr & width 2 mt, including interlocking/PCC plateform recommanded by OEM.
49S&F centrifugally cast (spun) ductile ironpressurepipes 80 mm dia with socket & spigotends having ISI stampingmarking with IS 8329/2000 classification K7, In standardlength of 5.5 - 6 mtr suitable for andincluding push on joint (gassket D jointing) with cement mortar liningin the pipes , complete all as specified & directed ofcomplete all as specified anddirected.
50Supply and fixing insulation on tubing offor 25 mm dia pipe and 13mm thick of nitrile rubber complete all as specified and directed.
51Supply and fixing Aluminium Cladding of 28SWG thickness on insulated pipe having 25 mm dia and 13mm thick nitrile rubber tube complete all as specified and directed.
52Supply, Install, lowering, testing, and commissioning of submersible openwell pumping sets, centrifugal, electric driven,minium discharge of 39.09 LPM at 40 mtr headmotor capacity minium 1.5 HP complete all specified and directed.(One main + one standby)
53M&L for PCC Block masonry valve pit of size 90x90x160 c.m (internal dimensions of chamber) built in CM 1:6 including 10mm thick plastering internally with cement mortar 1:6 and flush pointing externally as the work proceeds in same mortar complete with 5 mm thick MS sheet cover with angle iron 40 x 40 x 6mm frame, handle , locking arrangement and painting steel surface (cover inside and outside with frame) with two coats of synthetic enamel paint over a coat of red oxide primer including emebding angle in PCC complete.
54Supply and fix submersible copper conductor cable 3 core, 4 sqmm 1100v flat including nylon binding wire and accesories to clamp with column pipe at two places to each column pipe.
55Supply, installation &tesingof fully automatic star-delta starter for submersible pump set of following capacity 1.5 HP , 230 V , with relay range 10-16 amps 50 Hz 3 Phase complete.
56SCH "A PART - XIV(DG SET) Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 5 signifies this fact only
57Supply & installation of silent CPCB approved 1500 KVA TPDiesel Generating Set having diesel engine Liquid cooled, Electric start, four stroke, cold starting, TCI Aspirated, compression ignition, totally enclosed diesel engine with electronic governor , direct coupled ith 1500 KVA Three Phase alternator at 1500 RPM, 0.8 lagging power factor, providing Three Phase 415Volts suitable for 50 Hz, H class insulated winding, Close-direct-coupled, Self-excited and self-regulated type, screen protected, mounted on rigid MS sheet channel
58base-frame. The alternator shall confirm to IS: 13364, IS: 4722, BS5000, IEC: 34 and suitable for tropical condition. having fitted inside Canopy, fabricated out of 1.6 mm CRCA Sheet, cubical type, totally enclosed, Powder Coated, Control Panel and all accessories in- housed in a acoustic enclosure – sound proof canopy. Make: Cummins/ Kirloskar Green/ Powerol Mahindra & Mahindra/ Crompton Greaves.
59(B) Diesel Engine: - Adquate capacity of Diesel engine as accepted by the accepting officer based on manufacturers technical details water cooled to drive independently above alternator and after considering derating as per site conditons after generating and reducing power consumed by accessories directly coupled through flexiable coupling multi cylinder multi stroke direct injection,cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under :-
60i) Fly wheel with housing ii) Cooling system :- Moulded radiator with fan & belts. iii) Cooling Water pump : - Centrifugal type belt driven. iv) Exhaust System :- Exhaust System complete with exhaust piping of 150mm dia with MS pipe light grade upto & outside and 1meter away from the enclosure, covered with asbestos rope and aluminium foil of complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclousre. Exhaust gas turbo charger type, Exhaust manifold, Silecer : Residual type, Bellows
61v) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governer for 1% speed /frequecy regulation. Fuel filters, Fuel hoses vi) Lub oil System :-Lubricating oil filter, Lubricating oil pump vii) Air Intake System :- Air intake Manifold, Air cleanler dry type, viii) Governer :- Electronic Governer, ix) Starting System :- Electric Self starter with maintenace free battary including battary charging alternator.
62C) Batteries :- 24 VDC system Batteries of maintenece free of capacity as recommended by the manufacturer complete with copper conductor multistrnded leads of suitable length from self starter to the battary terminals complete with initial charge and initial fill of electrolyte all as specified of Make as per OEM. D) Starter gear ring, Start and stop push button, Ignition key / Switch, Handling and operation : Salient features of accessories shall be as under, Radiator with blower fan, Corrosion inhibitor coolant, Paper element filters for fuel, lub oil and by pass. Electronic governer controlled direct fuel injection system, Fly wheel housing and fly wheel.
63E) Generator Monitoring Control Panel : - Comprising of all standard items as mentioned under this schedule or as per standardpractice iginiton key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, water/coolent temparature indicator, Battary volt display including suitable size MCCBs and multifuction meter. xi) Safety Controls : - Engine low lube oil pressure high water temparature and over speeding of engine. xii) Coupling arrngement : - Flexiable coupling, fly wheel to suit flexiable coupling. xiii) Accessories :- AVM Pads built or separtely mounted to manufactrer base frames.
64xiv) Base Frame with anti vibration pads on base frame: - Made out of ISMC 250 of sturdy design made of MS channel with necessary reinforcement and predetermined holes. xv) MS pipe line to and from the fuel tank to the DG Set. (A) Alternator :-Standard design alternator rated at 1600KVA,net output at site after considering derating as per site conditions at 0.8 (lag) power factor AC,3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self exicited self regulated screen protected drip proof IP 23 enclosure brushless design with widing in pole faces, insulating class "H" and voltage regulation of+ 1% at rated voltage from no load to full load. The alternator shall be confirming to BS 2613/5000 and shall be inposition to generate supply with frequecy regulation with in + 1% tolerace. The alternator will be suitable for tropical climate and shall generally confirm to BS - 2613/5000/ IS - 4722.
65i) Insualation class - "H", ii) Temparature rise Class - "H", iii) Excitation : Self Excited, iv) Regulation performance: The voltage is kept constant with + 1%, manual voltage adjustment within + 5% . v) Frequency regulation + 1% F) Civil Works :- All civil works including PCC plat form as per manufacture"s design also 30 cm above the ground. The depth of the foundation and PCC as recommended by the manufacturer. G) Rubber Mattingof LV grade 19mm thick of suitable size chequred type ISI marked to be laid in front of control panel should be provided. Note:- The contractor shall arrange for artificial load for testing for final testing of DG Set at site and the cost is deemed to be including in above offer.
66H) Accoustic Enclosure:- Manufactured by OEM suitable for 1500 KVA DG Set. (i) NAL approved as per CPCB (ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board. (iii) The generating setbattaries and control panel should be inside the enclosure. (iv) Fuel tank should be out side the enclosure in the sub station building. v) The DG Set should be provided with external Emergency stop push button. vi) The battaries should be placed inside the enclosure beside the DG Set on a suitable inlsulatedplatform. viii) The enclosure should be suitably illuminated by suitable capacity of LEDfittings. xi) The noise level should be 75 db at 1m under free field conditions.
67xii) The accoustic enclosure parts shall be of powder coated after pre treat ment process. The powder coating shade should be Genset Green. The base frame should be painted with epoxy based black shade. xiii) Fuel tank as per manufacturer recommendation with inlet and outler connections and fuel level indicator. NOTE : - (i) TheGenerator set prime mover will produce at least 1735 BHP on 1500 KVA. (ii) Rate quoted shall be deemed to be inclusive of cable and terminations form Generator to the AMF Panel, with necessary holes to wall including making good to distrbed surfaces so as to match with the existing finishes all as specified and directed. (iii) The quoted rate shall be deemed to be inclusive of first filling of lubricant oil. (iv) The quoted rate shall be deemed to be inclusive of 12 hours test run at site including of half an hour on 10% overhead in presence of representative detailed by accepting Officer; including FOL, all arrangements are to be made by the contractor for tests.
68Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 1600 Amps.
69Supply, installation, testing and commissioning LT panel of suitable size as per IE rule and latest IS, factory made dust and vermin proof outdoor type made out of 3.15 mm thick CRCA sheet including seperate compartment for each MCCB & for cable and busbar, mounted on frame of MS angle iron 40mmx40mmx6 mm with front and back openable door with lock & Key including necessary grouting and double coat powder coated of grey colour painting complete with following accessories.The degree of protection of panel shall be IP-54 including foundation all as specified and directed.:- (DG Set Panel)
70INCOMING: [i] 4 pole ACB 2000 Amps with rupuring capacity 50 KA ,- 01 No (ii) Aluminium bus bar 3 phase 4 strip suitable for 3500 Amps current carrying capacitycomplete with post insulators and heat shrinkable sleeves- 01 No.. OUTGOING (i) 4 pole ACB 1600 Amps with rupuring capacity 50 KA - 02 No (For CHS Plant 1, spare) (ii) 4 pole MCCB 125 Amps with rupuring capacity 25 KA - 01 No (For DG Set Panel 1) (iii) RYBindication lamp -01 No. (iv)Voltmeter digital type with range 0-500 Volts -01 No. (v) Ammeter digital type with range 0-2000 Amp .
71Supply, installation, testing and commissioning LT panel of suitable size as per IE rule and latest IS, factory made dust and vermin proof outdoor type made out of 3.15 mm thick CRCA sheet including seperate compartment for each MCCB & for cable and busbar, mounted on frame of MS angle iron 40mmx40mmx6 mm with front and back openable door with lock & Key including necessary grouting and double coat powder coated of grey colour painting complete with following accessories.The degree of protection of panel shall be IP-54 including foundation all as specified and directed.:- (DG Set Panel No 1)
72INCOMING : (i) 4 pole MCCB 125 Amps with rupuring capacity 25 KA ,- 01 No (ii) Aluminium bus bar 3 phase 4 strip suitable for 250 Amps current carrying capacitycomplete with post insulators and heat shrinkable sleeves- 01 No.. OUTGOING : (i) 4 pole MCCB 63 Amps with rupuring capacity 25 KA - 02 No (For DG Set Panel 2, Spare) (iii) 4 pole MCCB 32 Amps with rupuring capacity 25 KA - 02 No (For FCU Feeder Piller Box 1 & 2) (iv) 4P,TPN 10 A with rupturing cap 16 KA - 01 No (Street Light for 16 Accn) (v) Timer for Street Light 20 Amps - 01 No (vi) RYBindication lamp -01 No. (vii)Voltmeter digital type with range 0-500 Volts -01 No. (viii) Ammeter digital type with range 0-2000 Amp .
73Supply, installation, testing and commissioning LT panel of suitable size as per IE rule and latest IS, factory made dust and vermin proof outdoor type made out of 3.15 mm thick CRCA sheet including seperate compartment for each MCCB & for cable and busbar, mounted on frame of MS angle iron 40mmx40mmx6 mm with front and back openable door with lock & Key including necessary grouting and double coat powder coated of grey colour painting complete with following accessories.The degree of protection of panel shall be IP-54 including foundation all as specified and directed.:- (DG Set Panel 2)
74INCOMING: (i) 4 pole MCCB 63 Amps with rupuring capacity 25 KA ,- 01 No (ii) Aluminium bus bar 3 phase 4 strip suitable for 200 Amps current carrying capacitycomplete with post insulators and heat shrinkable sleeves- 01 No.. OUTGOING: (i) 4 pole MCCB 32 Amps with rupuring capacity 25 KA - 03 No (For For FCU Feeder Piller Box 3 & 4, spare) (ii) 4P,TPN 10 A with rupturing cap 16 KA - 02 No (Street Light for 12 Accn, Water Pump) (iii) RYBindication lamp -01 No. (iv) Voltmeter digital type with range 0-500 Volts -01 No. (v) Ammeter digital type with range 0-200 Amp . (vi) Timer for Street Light 20 Amps - 01 No
75SCH "A PART - XV(HOT WATER SUPPLY) Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 5 signifies this fact only
76Supply and fixing of 5 star rated Water Heaters Storage type (Geysers) of Capacity 25 ltrs including grouting the nuts, bolts, washers of adequate size and all other accessories required at site for the effective functioning of the water heater complete all as specified and directed. Note : (i) Cost of Stop cocks deemed to be included in the quoted rate no extra payment shall be made. (ii) PVC connections, Bib cock and GI pipe shall be measured and paid seperately.
77SCH "A PART - XVICENTRAL HEATING SYSTEM) Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 5 signifies this fact only
78Electric Hot Water Generator : Supply, installation, testing and commissioning ofpackage type electric Hot Water generator constructed out of MS sheet having top open-able cover for easy access and removal of heaters. The HWG shall be suitable for indoor mounting. The generator shall be provided with 50mm thick fibre glass insulation 32 kg density finished with 0.8mm / 22G aluminium cladding sheet. The generator shall have electrical capacity of 400 kW. The heater shall be electrical resistance type, copper tube with chromium plating. The generator shall be complete with float valve, pressure gauge with ball
79valve, master and bank thermostats, etc. The generator shall be suitable for 3 phase, 415+ 10% Volts, 50 Hz. AC supply. The generator shall complete with self-contained incoming isolation, ammeter, voltmeter, contactors for heater banks in three steps complete with manual/auto rotary switches. (a) Allneccassary accessories required for the proper fucntioning of Hot Water Genearator are included in price. (b) The prices should include lifting, shifting and positioning of units at Site.
80(c) Hot Water Genearator installation to done as per Manufacturer recommendation with all installation requirements i.e Foundation, Vibration Isolator,Insulationetc as recommended by Manufacturer for the Ambient Temperature of Site. ODU installation is included in ODU price which includes the Civil Struture, Mechanical Structureetc as recommended byManufacturer. (d) The Contractor/OEM will shall submit the Hot Water Generator capacity/Burner Capacity as per ISO or equivalent standard. (e) OEM should submit the Installation and Maintenance Schedule/ Manual for the Boiler. Approved Make: (Make of Boiler: Emarald/Rapid Cool/Rapid Therm)
81GLYCOL CIRCULATION CENTRIFUGAL PUMPS: Supply, Installation, Testing & Commissioning of PN16 ratedAxial Split Coupled Vertical Inline water pump set with CI casing, Bronze Impeller, SS Shaft and externally flushed outside type balanced mechanical seal and non overloading motor, as per specifications and drawings. with Suitable HP(10 KW), TEFC squirrel cage induction motor with IE3 type class "F" insulation, Motor shall be rating of IP 55, operating on 415 ±10% volts, 3 phase, 50Hz AC Supply. The external flush line must be used for the purpose of heat dissipation from the mechanical seal.Pumps with performance characteristics as given
82below.The internal components of pumps including mechanical seal shall be suitable to sustain a fluid temperature of -25 Degree Celcius to 120 Degree Celcius. Vendor shall be provide antivibration arrangement for pumps . The scope also shall include following below mentioned : (i) Electrical by pass starter for pump set as recommended by OEM. (ii) 25 mm thick polyviny nitrile rubber insulation duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump.
83(iii) 3 Nos.- 150 mm dia type pressure gauges (iv) Mounting frame with antivibration pads (In case pumps are inline, anti vibration system shall be as per Manufacturers recommendation) (v) RCC/Cement concrete foundation for the pump unit. (In case pumps are inline, foundation shall be as per Manufacturers recommendation). (vi) Pump capacity are as under: (vii) Capacityand pump headnot less than flow 175 USGPM , Head 35 mtr each including the triple duct valve and End Suction guide. Make of Pump : Armstrong / Xylem /Grundfoss/Wilo. Note:- In 02 Nos working and 01 No standby configuration.
84EXPANSION TANK and Pressurisation Unit: Supply, Installation, Testing and commissioning of INSULATED PRESSURISED CLOSED WATER EXPANSION TANK suitable for total volume ofGlycol - Water Solution, circuit along with necessary accessories such as along with necessary accessories such as 2 Nos pumps (1working +1standby) with Pressure Transmitter andinterconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc.with Pressure Transmitter andinterconnecting Pipe & Isolating Valve complete with
85piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc. The tank shall be pre-charged. Expansion tank Shall be with replaceable heavy duty butyl rubber bladder. The tankconnection"s should be as per OEM recommendationsand 20 mm drain and charging valve connection to facilitate the on site charging of nitrogen in the tank.The tank shall be fitted with lifting rings and a floor mounting skirt for vertical installation. The tank must be constructed in accordance with IS-STANDARD 2825-1969 (withlates Revision)and Rated at PN 16 and ASME Stamped. The complete system shall be sourced
86from single manufacturer and supplied and installed with all accessories and safety fixtures required for proper functioning of the complete hydronic system.The tank shall be duly painted in approved colour shall be complete with pressure switches and power distribution and control panelIP55 Control Panel, Pressure Transmitter, interconnecting piping & wiring. (Tank capacity 500 Ltrs). Hot Glycol - Water closed vessel pressurized expansion tank as described above shall be duly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material or Equivalent U valueInsulating Material and cladded with aluminium Sheet (20G).
87(a)Expansion Tank of 1000 Lts capacity for Pocket-1 Approved Makes : Armstrong, Xylem , Grundfoss, Wilo, Anergy Instruments Pvt ltd
88(b)PRESSURIZATION UNIT: for Pump Set - 03 Nos (Ref. Point 4) with Control Panel and accessories for Pocket-1.
89Make Up TANK: Supply, installation, testing and commissioning of factory made Make up Water Tank, Rectangular/Circular shape, of 4 mm thick MS sheet (IS 2062), of capacity of 990 litres for Pocket-1complete with inlet, outlet, overflow, drain pipe of MS and vent with flame arrestor. Tank will be provided with supports made out of minimum 50mm angle iron duly painted, to keep tank base at minimum (1000mm) above FFL. Service platform shall be provided as per recommendations of OEM. The tank shall be provided with remote indication of levels provided level switches for on-off operation of tranfer
90pump. Extra high level and extra low level alarm shall be provided. Tank and structure shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.Make up Water tank as describedabove should beduly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material and cladded with aluminium Sheet (20G). Makes :Rapid Cool/ other MES approved makes
91Supply, Installation, Testing and Commissioning ofCeiling Suspended Fan Coil Unit having casing with bottom return Air Plenum complete including Direct driven fan (three speed) motor, operated on 230 volts, single phase, 50Hz, AC supply. Unit to be provided with inbulit 2way wall withcordless remote. The Ball Valve with Strainer/ Shut off Value with Strainer at inlet and outlet of FCU should be provided. The Unit Capacityshould becalculated as per BIS/ Eurovent Standard/AHRI Certification method.The below desired capacity should be calculated at Altitude of 3600 mts above sea level. Capacity calculation sheet to be provided to Engineer in Charge. The below mentioned capacity is at INLET TEMP: 65 Degree Celcius , OUTLET TEMP: 55 Degree Celcius and Below Mention External Static Pressure (ESP).
923 kW,ESP: 50 Pa (Reference Model No.:FWW200VC / Equivalent) (CHS Plant Room - Toilet n 1 Hav- 1 Qty Each )
935 kW,ESP: 50 Pa (Reference Model No.:FWW500VC / Equivalent)(CHS Plant Room - Duty n Study Room- 1 Qty each, 8-JCOs- Bed n LIVING Room - 8 Qty Each) Makes : FCU : Daikin (FWW/FUW Series), Midea(MKT Series), Trane,York,Carrier,Sinko Makes : Remote/Thermostat : Danfoss,Siemens, Honeywell, Belimo/ Ballorex/ JCI
94Supply, Installation, Testing and Commissioning of1.5 KW Steel plate Radiator( Wall Mounted) confirming EN- 442 , working pressurerange from 10-13 bar having workinh temparture of 110°C, complete with top grill side cover as standard along with inlet ,outley valve, Air purge valve andwith threaded plu as per OEM.The below desired capacity should be calculated at Altitude of 3600 mts above sea level. Capacity calculation sheet to be provided to Engineer in Charge. The below mentioned capacity is at INLET TEMP: 65 Degree Celcius , OUTLET TEMP: 55 Degree Celcius.
95M & L for Pre - insulated MS pipe,Class "C" havingminimum thicknes of PUF insulation as mentioned below and of density 36 Kg/Cum and 26 gauge GI/AL cladding complete suitable for above ground as per sizes shown.The pipes should be insulated with closed cell puf of density 36±2 Kg/Cum of below mentioned thickness. The Pipe should be workable in the temp. range of-50 Degree Celciusto120 Degreec Celcius. Note:-The Pipes size 150mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. Makes : ZECO/Seven Star/Lloyd/Parma Pipe/MES approved Supplier/Alaska Pre Insulated Systems
96Inside Building
97150 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding.
98100 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding.
9980 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding.
10065 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding.
10150 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding.
10240 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding.
10320 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding.
104Buried under ground/Exposed to Ambient:
105150 mm with 50 mm PUF thicknes and HDPE Cladding, 26 Gauge Al Cladding.
106100 mm with 50 mm PUF thicknes and HDPE Cladding, 26 Gauge Al Cladding.
10780 mm with 50 mm PUF thicknes and HDPE Cladding, 26 Gauge Al Cladding.
108Supply,Installation, Testing amd commissioning of PVC (minimum 15kg/sqcm pressure rated) drain water piping complete with fittings(elbows,tees, reducers,sockets,u trap etc.) supports, jointinginsulated with XLPE class O tubular insulation and any other item required to make the system compelete. Nominal diameters of pipe in mms as indicated below :
10925 mm dia pipe, Insulation thickness - 19 mm
11032 mm dia pipe, Insulation thickness - 19 mm
11140 mm dia pipe, Insulation thickness - 19 mm
112Supplying and installing 150 mm width X 50 mm depth X 1.6 mm thickness size cable tray of perforated, painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/Ground/wall with M.S. suspenders including bolts & nuts, painting suspenders etc. as required
113VALVES :
114Supplying, fixing, testing and commissioning of following diameter valves (PN-16 Rating) (Complete with Flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), strainers (Complete with flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), gauges etc for condenser water circulation as per specifications. Insulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified. Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets. Makes : Audco/C&R/Adverse/other MES approved make
115150 mm Ø Butterfly Valve
116100 mm Ø Butterfly Valve
11780 mm Ø Butterfly Valve
11840 mm Ø Butterfly Valve
11920 mm Ø Butterfly Valve
120Y - STRAINER (Insulated Valves) of Ductile CI Body flanged ends with stainless steel strainer forhot water circulation including Insulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified.
121100 mm Ø Y STRAINER
12220 mm Ø Y STRAINER
123NON - RETURN VALVE (Insulated Valves) with duel plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating forhot water circulation includingInsulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as sepcified. Makes:Audco/C&R/Adverse/Anergy/MES approved make
124100 mm Ø NRV
125Automatic Air Purge Valves forhot water circulation headeras specified and required by Engineer In Charge. Makes:Audco/C&R/Adverse/Anergy/MES approved make
126Automtic Air Purge Valve 20 mm Ø
127Air Separator :
128100 mm
129SITC of water pressure gauge (100 mm Ø) bourdon type with brass ball valve of 3/8" Ø and SS tubing, socket.Range (0-50) / (0-100) as required by Engineer In Charge.
130SITC of Mercury in glass industrial thermometer in SS-304 casing with 0.5 C least count, range 0-50 C. Brass oil filled thermowell of 1/2" size as required by Engineer In Charge.
131Electrical distribution Panel :
132Supply, installation, commissioning and testing of factory made, CPRI approved LTCHS Plant, indoor type made out of CRCA sheet 2 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, floor mounted and grounting the legs of panel in PCC foundation 1:4:8 complete as all directed suitable for and including the following :-
133INCOMERS (a) Bus Bar TPN Copper extensible type main bus bars of minimum of3000 A capacity (As per capacity of corresponding incoming / Bus couplers) , and auxilliary bus bars ofsuitable capacity with heat shrunk coloured sleeves and i/c SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of50kA . (b)ACB/MCCB 3000 Amps, 415 Volt, 50 KA, 4 Pole, thermal magnetic release - 01 No for incoming (Extended Rotary Operating Handle, Phase Spreader links and Phase barriers ) Make: Legrand/Schenider/Simens
134OUTGOINGS (c) 3Nos- .1000A 10 KA TPNMCCBwith Microprocessor release (3# Hot Water Generator) (d) MCB 5/6 Amp, 10KA, TPN - 04NosPressurization PUMPs /Diesel Pump/ Boiler pump (e) MCB 60 Amp, 10KA, TPN - 03 Nos for Pumps (f) MCB 5/6 Amp, 10KA, SPN,- 132No for Bldg load/FCU. Makes of MCBs: Legrand/Schenider/Simens
135(f) LED Phase indication lamps (01 Set) with 2Amp back up MCB,Breaker "ON/OFF" indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. - 2 Set (g) Digital Ammeter with in built ASS,metering C.T.s"CAST RESIN" type, 15VA, and accuracy class-1of 800/5A for measuring current in each phase - 01 Set. (h) All accessories prewired with appropriate size copper strip or wire and thimbles etc. all as required including foundations as per Manufacturers recommendations all as directed by Engnr-in-Charge.Note : Contractor will submit the drawing of panel to GE before execution for approval.
136L.T. CABLES :
137Supply & Laying/ fixing of following size XLPE insulated and PVC sheathed Copper conductor armoured cable/unarmoured as required of 1.1 KV grade complete as required. (ISI Marked) (in ground/in pipe/in duct/on surface/on cable tray)
1383.5 Core x 400 sq.mm. (Electric Hot Water Generator)
1394 Core x 10 sq.mm. (Pump)
1404 Core x 6 sq.mm (Pressurization Unit)
1412 Single corex 2.5 sq.mm. (FCU)
1424 Core x 4 sq.mm (Boiler Pump)
143EARTHING & MISCELLANEOUS ITEM :
144Earthing complete with GIearth plate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including GI strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main controlboard and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing making test point and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified & directed by Engr-in-charge.
145Supply and fixing rubber matting conforming to IS-15652-2006 complete as required. of size2m * 1m * 25 mm
146Glycol - Water Solution :
147Supplying of Ethylene glycol concentrate along with the necessary additives and inhibitor in cognition in sealed barrels complete all as directed.NOTE;- (i) The glycol concentrate shall be mixed with potable water supplied by contractor and filled in central heating system pipe line after proper leak test of entire circuit. The glycol water mixture ratio shall be 55:45 and freezing temperature shall be - 45 Degree Celcius (ii) First charge of glycol is included in the quoted rate. First Charge Include Charge in CHS pipe lineStorage Tank.
148CHS
149GLYCOL CIRCULATING PUMP: Supply, Erection, Testing and Commissioning ofTransfer pumps for the capacity of 5 LPM 5 meter head for Glycol Fluidtransfer with base frame foundation, bolts coupling coupling guard,TEFC, (OEM design HP for the required Flowand Head ) andother accessories for proper function of the pump.
150GENERAL NOTES :
151The rate for each item of work included in the Schedule of Quantities shall, unless expressly stated otherwise, include cost of : (a) All materials, fixing materials, accessories, appliances tools, plants, equipment, transport, labour and incidentals required in preparation for and in the full and entire execution, testing, balancing, commissioning and completion of work called for in the item and as per Specifications and Drawings. (b) Wastage on materials and labour. (c) Loading, transporting, unloading, handling/double handling, hoisting to all levels, setting, fitting and fixing in position, protecting, disposal of debris and all other labour necessary in and for the full and entire execution and for the job in accordance with the contract documents, good practice and recognize principles.
152(d) Liabilities, obligations and risks arising out of Conditions of Contract. (e) The unit rate for all equipment or materials in Indian Rupees shall include cost of equipment and materials including all taxes and duties and also including forwarding, freight, insurance and transport into Contractor’s store at site, storage, installation, testing, balancing, commissioning and other works required. The contractor shall perform Nitrogen test and vacuum test on refrigerant piping. Start and stop timing & pressure maintained shall be checked and the readings recorded shall be counter signed by consultant / client’s representative.
153Cable glands shall be compression type, heavy-duty chromium plated. All cable termination to have lugs/ thimbles. NSTRUCTION / MAINTENANCE MANUAL
154The Contractor shall prepare and produce instruction, operation and maintenance manuals in English for the use, operation and the maintenance of the supplied equipment and installations and submit to the Client / Consultant in (3) copies at the time of handing over. The manual shallgenerally consist of the following: (i) Description of the project. (ii) Operatinginstructions. (iii) Maintenance instructions including procedures for preventive maintenance. (iv) Manufacturers catalogues. (v) Trouble shooting charts. (vi) Schematic & control wiring diagrams.
155(vii) Commissioning Certificate. (viii) Also for BMS System, Training,Opeartion, Installation manual and Trouble shooting manual and Training should be imparted to the field person. (ix) Allneccassary license should be provided for the BMS free of cost. For Make List If any make stated below does not comply with the technical specifications and or IS Standards then such a make shall not be used in the work. MAINTENANCE OF PLANT AND TRAINING OF PERSONNEL The Cont ractor shall arrange to provide, at no extra cost, necessary personnel and material to carry out all routine maintenance of the CHS equipment as required regularly.