Tender For Provision Of Lt Vehicle Parking Shed, Provision Of Open Shed For Cars/Scooters, Provision Of Hard Standing And Spl Repair To Sunken/Toilet Of Bldg No 516 At Umroi Mil Stn Under Ge Umroi, umroi-Meghalaya

Military Engineer Services-MES has published Tender For Provision Of Lt Vehicle Parking Shed, Provision Of Open Shed For Cars/Scooters, Provision Of Hard Standing And Spl Repair To Sunken/Toilet Of Bldg No 516 At Umroi Mil Stn Under Ge Umroi. Submission Date for this Tender is 23-05-2024. Building Work Tenders in umroi Meghalaya. Bidders can get complete Tender details and download the document.




Tender Notice

43297378
Tender For Provision Of Lt Vehicle Parking Shed, Provision Of Open Shed For Cars/Scooters, Provision Of Hard Standing And Spl Repair To Sunken/Toilet Of Bldg No 516 At Umroi Mil Stn Under Ge Umroi
Open Tender
Indian
Meghalaya
umroi
23-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Provision Of Lt Vehicle Parking Shed, Provision Of Open Shed For Cars/Scooters, Provision Of Hard Standing And Spl Repair To Sunken/Toilet Of Bldg No 516 At Umroi Mil Stn Under Ge Umroi

Key Value

Document Fees
INR 500 /-
EMD
INR 89000.0 /-
Tender Value
INR 44.50 Lakhs /-

Attachment

FileName File Description File Size
4da6d2bf-700f-4284-9a05-dbfd32afe263.html Tender Notice 0 KB
8831TenderDocs.pdf Tender Document 0 KB
BOQ_730083.xls Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: PROVN OF LT VEH PARKING SHED, PROVN OF OPEN SHED FOR CARS/SCOOTERS, PROVN OF HARD STANDING AND SPL REPAIR TO SUNKEN/TOILET OF BLDG NO 516 AT UMROI MIL STN UNDER GE UMROI
Sl. No. Item Description
1Taking down cement plaster, of any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water, complete all as specified and directed
2Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed
3Material and labour forcoloured non skid ceramics tiles 7 to 8mm thick (square/ rectangular), area of each tile exc 0.06 sqm but not exc 0.11 sqm as in floors over and including 15mm thick screed bed/bedding layer in CM 1:4set and jointed in neat cement slurry and pointed in white/coloured cement to match the existing floor, complete all as specified and directed
4Material and labour for coloured Glazed ceramic tiles as in vertical surface 350x 250x 7mm/ 450X 350X7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and incl 10 mm thick rendering in CM 1:4 complete all as specified and directed.
5Taking down chowkats or frames exc 1.50 sqm but n.exc 4.00 sqm with shutters (without taking off shutters from the frame), complete all as specified and directed
6Taking down chowkats or frames n. exc 1.50 sqm with shutters (without taking off shutters from the frame), complete all as specified and directed
7Material & labour for 2nd class hard wood, plain, solid straight chowkats and frames worught, framed, rebated on the solid rounded or chamferred, put together with glue, pinned at joints supplied and fitted, complete all as specified and directed
8S&F solid PVC door frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with MS square tube fixed as per manufacturer instructions, complete all as specified and directed
9Supply and fixing 35 mm thick Flush shutter, solid core construction, with block board core and plywood face panels,commercial type on both sides, complete all as specified and directed
10S&F Factory made solid PVC moulded door shutter 28 to 30mm thick (stiles), with 2,4 or 6 raised panel design with 2mm thick moulded prelam PVC sheet on the front face & 2mm PVC sheet on back face, fixing in frame at site as per specification & drawing, complete all as specified and directed
11Supply and fix aluminium anodised (powder coated) Three track sliding window frame with shutters with ( 2 nos glazed and one wire gauzed shutter)including all necessary joining cleats, hold fast, rubber gasket, snap beading and locking arrangements fixed with screws to wall etc. complete andglazing with and including 5 mm thick tinted glass to aluminium frame work using rubber gasket and including stainless steel wire cloth of 0.36 mm dia & average width of aperture 1.40mm with staple or suitable fillets wire mesh fitted with screws and washers etc including aluminium grill of thickness 5mm and opening not exceeding 75mmx75mm etc completee with the following section of frame and shutter (A) Sections for shutter (i) "H" section 39 x 20 x 1.50 mm thick (ii) "Interlock" section 39 x 20 x 1.50 mm thick (iii) "Edge & Bottom" section 41 x 20 x 1.50 mm thick(B) Section for frame (i) Top & Sides 92 X 29.50X 1.50mm thick(ii) Bottom 92 X 29.70 X 1.50mm thick complete all as specified and directed .
12Supply and fix aluminium anodised (powder coated) Ventilator frame with Shutter (bottom Half Portion Fixedand top half portion with louver)including all necessary joining cleats, hold fast, rubber gasket, snap beading and locking arrangements fixed with screws to wall etc. complete andglazing with and including 4 mm thick frosted glass to aluminium frame work and louver using rubber gasket and fixed with stainless steel wire cloth of 0.36 mm dia & average width of aperture 1.40mm outside vent with staple and suitable wall angle of size 25.4x25.40x1.1mm thick and fillets with screws and washers etc including Deco Grill of Model / Design No. DG 104 and 6.3mm thick etc (A) Section for frame63.5 X 38.1X 1.40mm thick, complete all as specified and as directed.
13Material & labour preparation of new wooden surfaces of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed
14S&F aluminium alloy handle of size 150mm fabricated type anodised, complete all as specified and directed
15S&F aluminium anodised barrel tower bolt 150mm size of extruded section and fixed, complete all as specified and directed
16S&F aluminium alloy handles size 100mm fabricated type anodised, complete all as specified and directed
17S&F aluminium anodised barrel tower bolt 100mm size of extruded section and fixed, complete all as specified and directed
18S&F 300 mm long aliminium alloy, anodised sliding door bolt with hasp and staples (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections of cast alunimium alloy and fixed, complete all as specified and directed
19S&F 100 mm butt hinges medium weight cold rolled mild steel and fixed, complete all as specified and directed
20Material & labour for flat iron mild steel for hold fast size conforming to Fe-410-0 or Fe-310-0, complete all as specified and directed
21Taking up or down steel tubing 15mm bore and connections, complete all as specified and directed
22Taking up or down steel tubing 20mm bore and connections, complete all as specified and directed
23S&F CPVC pipes 20 mm outer dia of SDR 11 & plain CPVC SDR 11 and fittings as in walls, ceiling, floor etc, complete all as specified and directed
24S&F CPVC pipes 25 mm outer dia of SDR 11 & plain CPVC SDR 11 and fittings as in walls, ceiling, floor etc, complete all as specified and directed
25S&F in repair 600mm x 450mm bevelled edge mirror of selected quality glass, moulded on 6mm thick commercial ply wood and fixed to wooden plugs with chromium plated brass screw and cup washers, complete all as specified and directed
26S&F in repair PVC valve less syphonic action flushing cistern type 9 to 10 ltrs capacity with inlet, ball valve, float and handle including bracket, white colour, complete all as specified and directed
27Supply and fixed in repairs ofvitreous china squatting pan of Orissa pattern size 580 mm x 440mm white withP or S tap front or back inlet and integral foot rest (Excluding flushing cistern and flush pipe), complete all as specified and directed
28S&F in repair wash hand basin, white flat back of size 550 x 400mm excluding pillar taps but including waste cupling, waste pipe and bracket etc, complete all as specified and directed
29S&F in repair vitreous china wash down water closet (pedestal pattern) white with "P" or "S"trap front or back inlet, complete all as specified and directed
30M&L for Green Marble 16 to 18mm thick(table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of marble over and including 15mm thick screed bed/bedding layer in CM 1:4, complete all as specified and directed
31Material and labour for 15 mm thick rendering in cement mortar (1:6) on fair faces of brick surfacesfinished even and smooth without using extra cement, complete all as specified and directed
32Material and labour for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, chajja, fins, facia etc upto 3 storey height mixed with water proofing compound (ISI marked) @ 3% by weight of cement or as per manufacturer’s instructions, finished even & smooth without using extra cement complete all as specified. Note :- (a) Supply only water proofing compound shall be measured and paid separately under relevant items. (b) Cost of scafolding upto 3 storied height of building for rendering is deemed included inthe quoted ratethis item. (c) Rendering will be done in two layers. 1st layer will be 10 mm thick and 2nd layer will be 5 mm thick. .
33Supply only Liquid water proofing compound.
34Material and labour for 5 mm thick rendering in cement mortar (1:3) on concrete surface as in ceiling/chajja finished even and smooth without using extra cement, complete all as specified and directed
35Material and labour for applying three coats of white wash on ceiling including preparation of new or previously untreated surfaces, complete all as specified and directed
36Taking down soil pipe/ rainwater pipes (any size or pattern ) including all fitings heads shoes bends swan -necks etc (measured over all fixed along the centre line over fitting and ( accessories), complete all as specified and directed
37S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall including scafolding etc, complete all as specified and directed
38S&F for 110mm dia PVC bend etc with access doorfixed with rubbr ring fixed to wall including scafolding, complete all as specified and directed
39S&F for 110mm dia PVC (SWR) branch piece,single (single Y) equal or unequal with access door including scafolding, complete all as specified and directed
40S&F for 110mm dia PVC (SWR) junction single,(Single T) equal or unequal with access door including scafolding, complete all as specified and directed
41M&L for 100mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement, including making good distrubd area/surfaces with cement concrete/cement mortar 1:2:4 etc including taking down old unserviceable Nahani/Floor trap, complete all as specified and directed
42S&F in repairs15 dia fancy type chromium platedBib tap cast copper alloy etc, complete all as specified and directed
43S&F in repairs ofstop valve 15 mm dia CP fancy type, with long shank and cup (concealed type) cast copper alloy, screwed both ends for iron pipe or for unions, complete all as specified and directed
44S&F in repairs ofstop valve 15 mm dia CP fancy type, with long shank and cup cast copper alloy, screwed both ends for iron pipe or for unions, complete all as specified and directed
45S&F in repairs 15 mm dia fancy type pillar tap cast copper alloy, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe & fixed, complete all as specified and directed
46S&F in repairs Shower Rose 100mm size Chromium plated with swivel joints, any size, including fixing to steel pipe or union, complete all as specified and directed
47S&F in repairs Brass chromium plated tubelar towel rail, 20mm dia, D type, 60,cm long between flanges all as specified.
48Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth in brick walls etc complete.
49M&L for preparation of new plastered surfaces and applying two coats of oil emulsion distemper (any colour/tint)over a coat of primer on wall surfaces including rubbing with emmery paper to make wall surface smooth and even complete all as specified and directed.
50M&L for complete removal of existing finishes and treating with two coats of oil emulsion distemper (any colour/tint) over a coat of primer including rubbing with emmery paper to make wall surface smooth and even, complete all as specified and directed
51Material & Labour for preparation of new plastered surface of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified and as directed.
52Material & Labour for preparation of old plastered surface of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces, complete all as specified and as directed.
53M&L for preparation of old plastered ceiling surfaces and applying two coat of white wash (any colour/tint) on ceiling surfaces, complete all as specified and directed.
54Demolition of cement concrete of any dsecription and in any position not otherwise specifically provided for etc, complete all as specified and directed.
55M&L sunken treatment of Toilet/Bathroom as in following steps:i)Top of RCC slab in sunken portion includingperipheral beams shall be plastered with 15mmthick in cement mortar 1:3 using approved water proofing compound @ 3% by weight of cement finished even and smooth using extra cement,curved at the junctions. ii)Apply two coats of epoxy resin/polymer modified cementations coating like brush bond of FOSROK/SIKA/Pedilite or equivalent, both on floor & beams.iii)Sunken slabs to be given 1:20 slope outward 25mm GI pipe spout with 300 mm projection beyondouter surface of wall shall be provided.iv)Water tightness of sunken portion to be tested by ponding with water for 72 hours. In case of even a slight mark of seepage, the portion to be treated and ponding shall be carried out again to confirm the water tightness of sunken slab.Note : No cutting in roof slab/beam shall be allowed for passing of CI pipes & fittings.The stage of water proofing to sunken slab shall be passed by Eng-in-charge/GE.
56M&L for PCC 1:5:10 Type E2 (using 40mm graded crushedstone aggregate) as in filling sunken floor complete all as specified and as directed.
57M&L 25mm thick PCC 1:2:4 Type B-1 (using 20 mm graded crushed stoneaggregate) as in sub base of floor complete all as specified and as directed.
58M&L for 75 mm thick cement concrete 1:3:6 type C2 using 40 mm graded stone aggregate as in plinth protection finished fair and even and smooth with using extra cement, complete all as specified and directed.
59Material and labour for taking down of existing roof treatment from roof and terrace, roughening surface of old concrete roof by picking, sweeping clean and washing down with water to remove dust, etc and applying roof treatment with the following steps and specifications:- a) Applying crack seal compound of same manufacture of waterproof to fill all cracks of observed on the roof. b) Applying cement slurry over concrete surfaces @3kg/sqm. c) Rendering 15mm thick in cement mortar (1:4) mixed with water proofing compound as per manufactures’ instruction(not less than 3% by weight of cement) on cleaned concrete surfaces of roof and finishing the surfaces fair and even including curing the plastered surfaces for 7 days by ponding of water over the roof, (leveling course). d) Applying evenly one coat of primer coating (diluted with water in the ratio specified by Manufacturers) (min @100-110Sq Ft per liter (diluted quantity)) on the cleaned plastered surfaces. The surface shall be left for air dry for minimum period of 2-3 Hrs. e)Applying evenly one coat of elastomeric water proof coat in one direction (as specified by Manufacturers)(min@ 0.9-1.0 sqm per ltrs) and allow to air dry for 4-6 hrs before applying second coat in other direction perpendicular to the first one (as specified by Manufacturers) (min @0.9-1.0 sqm per ltrs. The total thickness of two coats shall be 0.5 to 0.6 mm. f) The whole system shall be left for air cure for min Seven days (without any movement). Make : - Dr Fixit Newcoat Ezee or Berger Home Shield PU RoofKoat or Asian Paints Smartcare Damp Proof or as equivalent approved by GE. Note : - (i) The waterproofing shall be carried out in the last stage of execution to avoid any damages during the execution. (ii) Payment against this item shall not be allowed till completion of all the stages of work for any slab. (iii) The work shall be executed through Authorized well-trained applicators as per manufacturer’s instructions after obtaining written approval from the GE
60Material and labour for complete/Partial removal of loose/ cracked concrete including cutting of reinforcement at Single/Double/Tripal storey if required from RCC roof projection, chajja, fins, facia etc and applying bonding agent as per manufacture instruction as per and making good with RCC (1:1.5:3) type A0 using 12.5 mm graded aggregate) in any slab and in any position finsihed the surface even and smooth with out using extra cement including necesary formwork and welding/binding of reinforcement if required, complete as directed by Engineer in charge. Note:- (1) reinforcement will be measured and paid seperately under respective items, (2) Rate shall be inclusive of bondig agent fosroc nitobond EP ,Sika hibond, Pidilite 301 pidicrete URP. (3) The quoted rate shall be inclusive of Scaffolding if required.
61M&L for Mild steel TMT bars 5 mm to 10 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips, complete all as specified and directed.
62S&F in repairs PVC connection pipe 15mm size with PTMT nuts of length 450mm long, complete all as specified and directed.
63Supply and fix in repair of rotational moulded,HDPE water storage tank of 1000 ltrs capacity( Cylindrical vertical with closed top)ISI marked hoisted and fixed in position all as specified in SSR Part I including 02 Nos 20 mm bore full threaded GI nipple of required size including ball valves 20 mm bore high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed (Minimum weight 20mm - 210gms and refixing of inlet, outlet & over flow pipe etc, complete all as specified and as directed
64Surface excavation not exceeding 30 cm deep and averaging 15 cm and getting out in soft/loose soil, complete all as specified and as directed
65Excavation in post holes (or similar holes) each not exceeding 0.50 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exceeding 50 m and making good surfaces in soft/loose soil, complete all as specified and as directed
66Excavation in trenches not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth and getting out in soft/loose soil, complete all as specified and as directed
67Material and labour for providing Plain Cement Concrete (1:4:8) type D2 using 40 mm graded aggregate as in foundation, filling and mass concrete, complete all as specified and as directed
68Material and labour for Pre-cast cement concrete block masonry Type C1 (1:3:6) (using 20mm graded aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar (1:6), complete all as specified and directed.
69Returning, filling in trenches including spreading, leveling watering and ramming in layers not exceeding 25cm, complete all as specified and as directed
70Removing of surplus to a distance soil not exceeding 50 m and deposited where directed at a level not exceeding 1.50m above the starting point, complete all as specified and as directed
71Material and labour for providing hardcore of broken stone of gauge not exc. 63 mm deposited, spread and leveled in layers not exc. 15cm thick, watered and rammed to a true surface, complete all as specified and as directed
72M&L for 75 mm thick PCC(1:3:6) type "C-2" (using 40mm graded crushed stone aggregate) as in flooring, complete all as specified and as directed
73M&L for 100 mm thick PCC(1:2:4) type "B-2" (using 40mm graded crushed stone aggregate) as in flooring, complete all as specified and as directed
74M&L for 75 mm thick PCC(1:4:8) type "D-2" (using 40mm graded crushed stone aggregate) as in flooring, hardstanding complete all as specified and as directed
75Material and labour for providing Plain Cement Concrete (1:3:6) type C2 using 40mm graded aggregate as in Pillars, boundary pillars, posts etc. filling and mass, complete all as specified and as directed
76Supply and fix steel work in tubular vertical post including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161 – 1979 grade St – 240, complete all as specified and as directed
77Ditto- as per item No-76 but as in truss andpurlin
78S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of camouflage colour having tensile strength of 550 Mpa as in roof covering/clading to wall, fixed with self taping screws, complete all as specified and as directed
79S&F Pre- painted galvalume aluminum zinc coating PPGL based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, eave board, fixed with self tapping screws, complete all as specified and directed.
80Material and labour for 15 mm thick rendering in cement mortar (1:4) on fair face of brick or concrete surface finished even and fair, complete all as specified and as directed
81M&L Sand Spreading and levelling under inter locking paver block, complete all as specified and as directed
82M&Lfor machine pressed precast concrete interlocking rubber moulded paver block with grey cement and no pigment any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade, complete all as specified and as directed
83M&Lfor prepainted machine pressed precast concrete interlocking rubber moulded paver block with grey cement and colour pigment any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade, complete all as specified and as directed
84M&L for plain cement concrete, type B0 (1:2:4) (using 12.50mm graded stone aggregate) as in cills, steps; seismic and other similar bands, hold fast, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, Copings, etc including necessary formwork, complete all as specified and as directed
85Material and labour for preparation of new and previously un-treated steel surfaces of any description, not otherwise described over 10cmwidth or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and as directed
86Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc, complete all as specified and directed.
87Taking down carefully MCB DBs SP/TP by unscrewing from main switch boards/cut out boxes and removing materials to store for keeping in safe custody for reuse at site or for taking credit including sealing the cable ends and making good disturbed surface of wall etc as per existing finishes, complete all as specified and directed by the Engr-in-Charge.
88Material and labour for point wiring for One light/fan point controlled by one,one way switch, with 1.5 Sqmm single core, PVC FRLSH insulated unsheathed, multistranded copper conductor drawn through and includingPVC casing and caping including necessary accessories like bends, tees, PVC square and elbow etc fixed on wall/ceiling with 1.5 Sqmm PVC FRLSH insulated unsheathed multi stranded copper conductor cable as earth conitinuity (green in colour) connected to common earth dolly including sunken type pressed steel terminal boxes of suitable sizes with plastic laminated white/coloured top sheet cover 3 mm thick complete all as specified and directed as below :- Note:-Rate forCutting, chieseling and making good the existingsurface for complete concealed wiring is deemed to be included in quoted rate, complete all as specified & directed.
89All as per Sr. Item No. 88 herein-above but for One 5 Pin 5 Amps socket out let point onindependentboard.
90All as per Sr. Item No. 88 herein-above but for One 5 Pin 5 Amps socket out let point on same board alongwith othersuitable switchs.
91All as per item No 88 here-in-before but using 2.5 sqmm PVC FRLS insulated copper condutor wire for connecting 15A socket on independent board.
92Supply and fixing of switch piano flush type 240 Volts 5 Amps, SP, one way, complete all as specified & directed
93Supply and fixing switch socket out let combination multipurpose 5 pin, 5/16 Amps and (with 3 pin 5 Amps outlet also) flush type (non shuttered), complete all as specified & directed
94Supply and fixing socket outlet multipurpose 3 pin, 5 Amps, 240 volts flush type (non shuttered) on same board, complete all as specified & directed
95Supply and fixing switch socket out let combination multipurpose 5 pin, 5 Amps and (with 3 pin 5 Amps outlet also) flush type (non shuttered) in independent board, complete all as specified & directed
96Supply and fixing ceiling rose surface PVC/Polycarbonate, 65x50 mm two to three terminals, complete all as specified & directed
97Supply and fix of MCB SPN DB 4 waydouble door,IP 43 protection,Glazed door, isolated neutral bar, insulated bus bar assembly, mechanical strength of IK09, complete all as specified and directed
98Supply and fix of MCB SPN DB 8 waydouble door,IP 43 protection,Glazed door, isolated neutral bar, insulated bus bar assembly, mechanical strength of IK09, complete all as specified and directed
99Supply and fix MCB SPN 40Amp, complete all as specified & directed
100Supply and fix MCB SP 6-32 Amp, complete all as specified & directed
101Supply and fix LED batten with Tube rod of capacity 18/20Watt , complete all as specified & directed
102Material and labour for earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick, burried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to earth lead wire 4 mm dia by means of nuts, bolts and washers of galvanised iron and earth lead protected by galvanised iron pipe 15 mm bore (light grade) and connected to earth test point and including cement concrete pit in PCC (1:3:6) type C-1(using 20 mm graded aggregate) and pre-cast RCC cover slab of size 540 x 540 x 50 mm thick, reinforced with 8 mm dia TMT bars both ways and one handle for lifting made with 10 mm dia mild steel bar,funnel, wire mesh 20 mm bore galvanised (medium grade) for watering, charcoal and salt in alternate layers including necessary execuation and earth works in any types of soil complete all as shown on Electrical plate No 3 of MES SSR-I including, complete all as specified & directed.
103Supply and spread sand in trenches as sand cushioning to underground cable for protection with fine river sand and provide required cover after punning down complete all as specified and directed. (Note: Thickness of sand cushion after punning down will be measured and paid.)
104M&L for common burnt clay building bricks (locally available best quality), sub-class ‘B’ designation 75 of size 230x115x75 mm to cover LT underground cables , laid dry and flat abutting each other with gaps not exceeding 10mm, complete all as specified and directed.
105Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6.0 sq mm 2 core, complete all as specified and directed.
106Supply & fix MCB SPN 32 Amps"C" Series 10 KA 240 volts, complete all as specified and directed.
107Supply and fixing Bulb holder angular PVC/Polycarbonate suitable for batten fittings, complete all as specified and directed.
108M&L for cutting of circular hole in any type of wall suitable size for fixing of exhaust fan of size 300mm sweep, grouting 04 Nos 100mm long 12mm dia stud bolt including making good to disturbed surfaces of wall to match as per the existing colour complete as directed and specified
109S&F of exhaust fan 300 mm (minimum) sweep, metal body, light duty, 1200 RPM (minimum), AC single phase 230 watt, 50 Hz with bird guard, nuts, screw, bolts including electrical connection, complete all as specified and directed. Make:- Usha / Havells / Orient / Bajaj / crompton
110Supply and fix LED fitting 1x18watts including Tube rod, 230 Volts, bipin holders connector block etc.complete with all accessories internally pre-wired and includingprovision of PVC round block 7.5cm dia and 2 cm in depth (2 Nos) for mounting the fittings and electrically connecting with three single core 23x0.0076 PVC insulated multistranded copper conductor flexible cable from ceiling rose to light fitting, complete all as specified and directed.
111Material & labour for Sub main wiring with two runs of single core 6 Sqmm (Nominal Area) FRLSH PVC insulated and unsheathed multi standed copper conductor cable LT 1100 volts grade drawn thorugh and including PVC casing capping of adequate size fixed on surfafce of wall/ceiling with all necessary fittings and accessaries and 1 run of FRLSH PVC insulated and unsheathed insulated single core cable with multi standered copper conductor of size 6 Sqmm as earth wire (green in colour) run through casing capping and connected common earth dolly including taking out the old sub main wiring two run of 6 Sqmm cable one run of casing capping and one run of 6 Sqmm earth continuity wire for connection to DBs/dolly shall be deemed to be included in this item and shall be measured as one run and including taking down old submain wiring, complete all as specified and directed. Note:- Three runs of 6 sqmm cable and one run of PVC conduite shall be measured as one unit.
112Supply and fix LED bulb of 9 watt (warm white), complete all as specified and directed.
113Schedule of Credit
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail