Tender For Repair To Roof Ceiling Flooring Plinth Protection Brick Work And Plastering In C2a And C2b Area Under Ge (East) Mathura, mathura-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair To Roof Ceiling Flooring Plinth Protection Brick Work And Plastering In C2a And C2b Area Under Ge (East) Mathura. Submission Date for this Tender is 25-05-2024. Building Work Tenders in mathura Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43297281
Corrigendum : Tender For Repair To Roof Ceiling Flooring Plinth Protection Brick Work And Plastering In C2a And C2b Area Under Ge (East) Mathura
Open Tender
Indian
Uttar Pradesh
mathura
25-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Repair To Roof Ceiling Flooring Plinth Protection Brick Work And Plastering In C2a And C2b Area Under Ge ( East ) Mathura

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-May-2024 AMENDMENT BOQ 25-05-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 100000.0 /-
Tender Value
INR 50 Lakhs /-

Attachment

FileName File Description File Size
1a4d0556-151e-418c-94ae-c0092c3a4e6c.html Tender Notice 0 KB
BOQ_730076.xls Tender Document 0 KB
TENDER.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work:REPAIR TO ROOF, CEILING, FLOORING, PLINTH PROTECTION, BRICK WORK AND PLASTERING IN C2A AND C2B AREA UNDER GE (E) MATHURA
Sl. No. Item Description
1Dismantling plain or corrugated steel sheet including ridge, hips, valley and flushing etc of any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed.
2M&L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
3M&L Pre- painted galvalume aluminium zinc coating GI based plain steel sheet 0.5 mm thick of any colour having tensile strength of 550 Mpaas in ridges/valley gutters, fixed with self tapping screw complete all as specified and as directed.
4Dismantling asbestos cement (corrugated or semi-corrugated etc) sheets in roof covering including ridges, hips, valleys and flashings etc complete all as specified and as directed.
5S&F 6mm thick asbestos cement, corrugated or semi-corrugated sheets fixed with L-type or J-type or cranked hook bolts in roofs, wall etc. complete all as specified and as directed.
6S&F asbestos cement one piece plain angular ridge 6mm thick fixed with L-type or J-type or cranked hook bolts inroofs, walls etc. complete all as specified and as directed.
7Dismantling Fibre glass reinforced translucent corrugated sheeting in roof covering, walls etc complete all as specified and as directed.
8S&F 2mm thick Fibre glass reinforced translucent corrugated sheeting with two corugations side lap fixed with coach screw and washers in roofs, walls etc complete all as specified and as directed.
9Dismantling timber scantlings (framed work) 40sqcm and over in section, in any position complete all as specified and as directed.
10M&L for Mild steel work in tubular trusses, purlins, vetical posts including special shaped washer, angle cleats, fish plates, gusset plates, base/bearing plates, bolts and nuts etc. complete using ERW or induction butt welded tubes conforming to 1161-1979 grade st 240 complete all as specified and as directed.
11S&F MS flat iron wind tiesfor roof including all necessary drilling, bolting or riveting etc conforming to Fe-290 Gde E-165 complete all as specified and as directed.
12Demolition of roof treatment including PCC/ Brick Tiles, Mud phuska PCC padding, plastering, APP membrane complete treatment of any thicknesss and in any position and removing the demolished material out of MoD land complete all as specified and as directed.
13M&L for 40 mm thick (avg) thickness cement concrete 1:2:4 type B0 (using 12.5 mm graded aggregate) as in floors, roof padding to achieve required slope finishing the surface even and smooth without using extra cement complete all as specified and as directed.
14M&L for Cutting grooves in brick wall, 75mm wide and 65mm deep and facing horizontal face to groove with cement mortar 1:3 complete all as specified and as directed.
15M&L for bitumen felt water proofing treatment using APP based polymeric membrane minimum weighting 3.00kg/sqm and minimum thickness 3mm reinforced with polyster non wove fabric (but not less than 150gms/sqm) laid over and including bitumen primer applied @ 0.30 Kg/sqm by forced application complete all as specified and as directed.
16M&L for cement concrete tiles 25cm x 25cm x 25mm thick, with grey cement and no pigments, machine pressed, set jointed and pointed in neat cement slurry in floorlaid over and including 15 mm thick screed bed in cement mortar 1:6 and filling the joints with Tile Max premium cementitious grout material complete all as specified and as directed.
17M&L for Providing cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in roof kerbs, mud stops & coping etc, rounded chamfered on edge complete all as specified and as directed.
18Dismantling wall and ceiling boards (fiber, pulp, insulation, etc) or insulation board/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed.
19S&F in repairs solid PVC wall lining and solid PVC partion consisting of 5mm thick plain coloured PVC Sheet inclusive of solvent cement and fixing at site on PVC frame as shown on drawing complete all as specified and as directed.
20S&F 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC frame as per specification complete all as specified and as directed.
21S&F anodised aluminium snap grid(size605x605mm) frame work for false ceiling including Hangers 6 mm dia GI (upto 1200 mm length) adusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified and as directed.
22S&F 4mm thick Non asbestos fibre cement building boards fixed or laid/inserted to timber/GI/Aluminium frame work with screws as in ceiling flat or sloping complete all as specified and as directed.
23Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
24M&L for 25 mm thick (average) thickness cement concrete 1:2:4 type B0 (using 12.5 mm graded aggregate) as in leveling course below tiles fiinishing the surface even and fair without using extra cement complete all as specified and as directed.
25M&L for Vitrified Ceramic light shade tiles 10 mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15 mm thick screed bed in cement mortar 1:4 complete all as specified and as directed.
26All as per item No 25.00 here-in-before but as in skirting/dado laid over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and as directed.
27Demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
28M&L for 50 mm thick cement concret type C-1 1:3:6 (using 20 mm graded stone aggregate) as in plinth protection, finishing cement concrete surface even and smooth without using extra cement compete all as specified and as directed.
29M&L for 75mm thick cement concretetype B1, 1:2:4 (using 20 mm graded stone aggregate) as in floors and paving etc finished surface even and fair using extra cement laid in alternate bays & joints filled with bitumen and sand mixed in 1:3 complete all as specified and as directed.
30M&L non skid ceramic ENDURA coloured tiles 10mm thick (square/rectangular) area of each tiles exc 0.06 Sqm but n. exc. 0.11 Sqm set and jointed in neat cement slurry & pointed with coloured cement to match as in floors laid over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and as directed.
31M&L for Chequered cement concrete tiles with white cement and pigment 20cm x 20cm x 25mm thick rubber moulded glossey finish, set, jointed and pointed in neat cement slurry in floors laid over and including 20mm screed bedding in cement mortar 1:6 complete all as specified and as directed.
32Demolition brick tiles/machine pressed precast concrete interlocking paver block any size laid in bedded and pointed in any mortar complete all as specified and as directed.
33M&L for Machine pressed precast concrete interlocking paver blockwith grey cement and pigmentany shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade complete all as specified and as directed.
34All as per item No 33.00 here-in-before but except interlocking paver block complete all as specified and as directed. Note : The serviceable tiles shall be reused from item serial No 32.00 of this BOQ.
35M&L for 100mm thick cement concrete type D2 1:4:8 (using 40mm graded stone aggregate) as in sub base Sub floor, foors and paving etc complete all as specified and as directed.
36M&L for sand filling under floors or in foundations including consolidation complete all as specified and as directed.
37M&L for cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in coping surface channels, benchings, manholes finished even and fair complete all as specified and as directed.
38Demolition of brick work built in cement mortar including all quoins, asches, pillars etc in any position complete all as specified and as directed.
39M&L for Brick work with old size Fly ash Bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
40Dismantling fencing wire mesh any type complete all as specified and as directed.
41Supply only MS galvanised chain link fencing any size or type complete as specified and as directed.
42Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete as specified and as directed. Note : (i) Supply only fencing will be measured and paid separately. (ii) Supply & Fix mild steel nut, bolts and flat will be measured and paid separately.
43S&F Mild steel work as in hand rails, half round or other section, balustersrunning bars, nosing to steps, wind ties, posts and struts in fencing incl cutting tops to shape as required, drilling holes , noching for wire , flat iron fillets for securing wiremesh etc. incl all necessary drilling, bolting or riveting etc & similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
44S&F Mild steel screw bolts (machine made)5 to 10mm dia with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and as directed.
45S&F in repair galvanised 2 strand steel barbed wire 2.24mm, dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provn of galvanised mild steel wire staples or steel pins complete as specified and as directed Note: (Each line wire to be measured)
46Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and as directed.
47M&L for MS framed work as in doors or gates of angle or other sections with gusset plates, rails braces etccomplete drilled for fixing of steelsheetingor other covering to doors etc to be prepared for hanging or sliding with and including either hooks and pintel hinges or steel hanging door etc, (exclusive of steel sheeting or other covering running rails & guides) also fastening and fixing complete all as specified and as directed.
48M&l for preparation of new steel surfaces of any description,not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
49Taking down cement plaster of any description from brick walls or concrete surface including raking outjoints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
50M&L for 10mm thick rendering on fair faces of brick work or concrete surfacein cement mortar 1:6 finished the surface even and fair without using extra cementcomplete all as specified and as directed.
51M&L rendering 15mm thick on other than fair face of brick work orconcrete surface in cement mortar 1:4 by mixing liquid water proofing compound as per manufacturers instructions and finishing surface even and fair complete all as specified and as directed. Note :- Liquid WPC shall be measured & paid separately under relevant item of this BOQ.
52Supply only liquid water proofing complete all as specified and as directed.
53M&L for rendering 5 mm thick in cement mortar 1:3 over and including 10 mm thick dubbing coat in cement mortar 1:4 as on ceiling surfaces of concrete finishing the surface even & smooth without using extra cement complete all as specified and as directed.
54M&L for preparation of new plastered surface of walls and applying two coats of cement base paint over and including a coat of alkali resistant primer complete all as specified and as directed.
55M&L for preparationof new plastered surface of ceilling and applying threecoats of white washcomplete all as specified and as directed.
56M&L for preparing of new plastered surfaces of walls and applying two coats of exterior emulsion paint Apexover and including a coat of alklai resitant primer complete all as specified and as directed.
57M&L for prepration of new plastered surface of walls and providing 1mm thick wall care putty complete all as specified and as directed.
58M&L for preparation of new plastered surface of walls and applying two coats of distemper oil emulsion over and including a coat of primer complete all as specified and as directed.
59Taking up or down mild steel tubes galvanized iron 20 mm bore dia and connections and removed from site complete all as specified and as directed.
60S&F for 20mm bore mild steel tubes, medium grade, galvanisd with all fittings fixed complete to walls, ceiling or laid in floors complete all as specified and as directed.
61S&F rotational moulded polyethylene water storage tank (Triple layers white in colour) (Cylindrical vertical with closed top) hoisted and fixed in position 500 liters capacity including connections and dismantling existing old u/s water storage tank complete all as specified and as directed.
62S&F rotational moulded polyethylene water storage tank (Triple layers white in colour) (Cylindrical vertical with closed top) hoisted and fixed in position 1000 liters capacity including connections and dismantling existing old u/s water storage tank complete all as specified and as directed.
63S&F ball valveshigh pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for 20mm bore dia pipe and fixed ( Minimum weight 210 gms each) complete all as specified and as directed.
64S&F in repairs cover for HDPE water tank of capacity 500 & 1000 ltrs rotating type with frame including nut bolt complete all as specified and as directed.
65S&F in repairs ball valveshigh pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for 20mm bore dia pipe and fixed (minimum weight 210 gms each) complete as specified and as directed.
66S&F in repair Gun matel, globe or gate valves with iron wheel head, screwed both ends for iron pipe 20 mm bore dia and fixed all as specified and as directed
67S&F in repair 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with suitable MS clamps of size 25x3mm at two mtr spacing complete all as specified and as directed.
68S&F in repair 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with suitable MS clamps of size 25x3mm at two mtr spacing complete all as specified and as directed.
69S&F in repair 110mm bore PVC (SWR) bends any radius complete as specified and as directed.
70S&F in repair 110 mm bore PVC (SWR) junction single, (Single T) equal or unequal provided with acess door complete as specified and as directed.
71S&F in repair 110 mm bore PVC (SWR), vent cowl complete as specified and as directed.
72S&F in repair 75mm bore PVC (SWR) bends any radius complete as specified and as directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail