Sl. No. | Item Description |
1 | Demolition of cementconcrete (unreinforced) of any description and in any position not otherwise specifically provided for complete and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed. |
2 | Demolition of cement concrete reinforced (reinforcement cut as required to facilitate demolition) in ground floor and pavingn.exc 15 cm thick above or below ground level complete and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed. |
3 | Demolition of brick workor stonework built in cement mortar including allquoins, arches pillars etc but excluding ashlar facings ,dressed stonework and precast concrete articles and stacking the serviceable materials within 100m and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed. |
4 | Taking down cement plaster including backing etc from brick/stone walls / concrete surfaces including raking out joints,hacking for key , scrubbing down with water etc complete all as specified and directed |
5 | Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubish off the premises. complete all as specified and as directed. |
6 | Dismantling plain or corrugatedsteel sheetsany gaugethickness including Nanital or similar pattern roof covering including ridges complete all as specified and directed. |
7 | Demolition of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed. |
8 | Taking downsteel water tubing 15 mm bore including all fitting and connections complete all as specified and directed. |
9 | Taking downsteel water tubing 20 mm bore including all fitting and connections complete all as specified and directed. |
10 | Dismantling wrought iron or mild steel work of any description not otherwise provided forcomplete all as specified and directed. |
11 | Taking downand removing chowkats with shutters (withouttaking off shutters from chowkat)not exceeding 1.50 Sqmeach complete all as specified and directed. |
12 | Taking downand removing chowkats with shutters (withouttaking off shutters from chowkat)exceeding 1.5 Sqm but not exceeding 4 Sqmeach complete all as specified and directed. |
13 | Resecuring or easing & adjusting without taking down Shutters of any descriptionexc 1 sqm but not exc 2 Sqm each, complete all as specified. |
14 | Dismantling water tanks of capacity exceeding 500 Litres but not exceeding 1000 Litres, complete all as specified and directed. |
15 | Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in hard/dense soil, complete all as specified and directed. |
16 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25Cm, complete all as specified and directed. |
17 | Removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed. |
18 | Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron, complete all as specified. |
19 | Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors, complete all as specified. |
20 | PCC 1:2:4 (nominal mix) type B-2(using 40mm graded crushed stone aggregates) as in kerbs and mud stops, rounded or chamfered on edges and similar works, complete all as specified and directed. |
21 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex tra cement, including forms, moulds, mitred/stopped ends etc all as specified and directed. |
22 | RCCType A-1, 1:1.5:3 (20mm graded crushed stone aggregate)chajja/facia/parapet/railing and the like complete all as specified and directed. |
23 | Use & waste of form work to suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished surfaces of flat concrete, complete all as specified & directed. |
24 | Use & waste of form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide for rough finished surfaces of concrete, complete all as specified & directed. |
25 | Brick work with old size fly ash bricks, straight or curved on plan exc 6 m mean radius built in in cement mortar 1:6 all as specified & directed. |
26 | Walling of random rubble stone masonry, uncoarsed, well bonded, bedded and soilidly hearted,built in CM 1:4, complete all as specified and directed. |
27 | 2nd class hardwood (Sal) plain solid straight chowkats and frames wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed. |
28 | 35mm thickFlush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
29 | Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing as shown on page No176 to 183 of MES SSR 2020 Part-II compete all as specified and directed. (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life) |
30 | Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails.M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and wood grain printed PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Pane of 4 mm thick sheet glass to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable 5mm thick x15mm wide PVC sheet beading used inside stiles and rails anddecorative PVC beading of 10mm x 10mm (900 ), and joined together with solvent cement, suppling & fixing in the frame at site, complete as shown on page No176 to 183 of MES SSR 2020 Part-II compete all as specified and directed. |
31 | 35 mm thick2nd class hard wood (Sal/Hollock) glazed & skeleton factory made shutters, open rebated and prepared to receive glass, gauze etc (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass, etc, sizes of members ofdoor shutters as specified in SSR- 2009Part-I Section 8.24(a) complete all as specified and directed. |
32 | Aluminium handles, cast type, anodised of size 150 mm complete all as specified and directed. |
33 | Aluminium anodised, barrel tower bolts of extruded section and fixed of size 200 mm, complete all as specified and directed. |
34 | Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21, 100mm long, complete all as specified and directed. |
35 | 300mm longaluminium alloy, anodized, sliding door bolt with hasp, staple(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed. |
36 | Galvanished mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanished wire staples complete all as specified and directed. |
37 | Sheet glass, 4.8mm thick ordinary quality and glazing with oil putty in squares n.exc 0.5 sqm each pane complete all as specified and directed. |
38 | Drapery/Curtain rod 25mm dia fancy type, fabricated out of mile steel sheet not less than 20 gauge, including brackets and pair of decorated end knobs(finials), stop roller etc, pretreated powder coated natural colour complete all as specified and directed. |
39 | 300mm, Mild Steel, ordinary rat tail rod pattern springs including roller and roller plate completeall as specified and directed. |
40 | Aluminium anodised snap grid frame work of size of size 605 mm X 605 mm as in false ceiling, flat or sloping (pattern as per manufacturer"s catalogue/ instructions), cuttingholes for electrical fittings fixed on and including aluminium tee of size 25mmX25mmX1.50 mm as main runner, aluminium tee of size 25mmX25mmX1.25 mm as cross runner and aluminium angle of size 25mmX25mmX1.25mm at the perimeter suspended from soffit at approx 900 mm centre to centre with hangers 6 mm dia galvanised (length as per site requirement) adjusting level fixed to roof by means of ceiling cleats made out of galvanised iron flat 40 mm X 3 mm size, 60 mm long and expansion hold fasteners 12.5 mm dia, 40 mm longincluding 12mm thick Perforated particleboard/tiles, as in ceiling for insula-tion and accoustic purposes, 60x60 cm in size, fixed withstaples on snap grid including necessary scaffolding all as specified and directed. |
41 | 0.63 mm thick, galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with with L-type or J-type or cranked hook bolts ,in roofs, walls etc. with grade of zinc coating 275 gms per sqm complete all as specified and directed. |
42 | 0.63 mm thick, galvanised, plain mild steel sheetingas in ridges, hipe, valley gutters, drip and straight flashing (length and girth as fixed)with grade of zinc coating 275 gms per sqm complete all as specified and directed. |
43 | Mild steel Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary,gusset plates, riveting, etc., conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
44 | Mild steel TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed. |
45 | 75mm thick PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregates) as in sub base of flooring/ hard standing, finished even and smooth without using extra cement complete all as specified and directed. . |
46 | Plain cement concrete 1:3:6, nominal mix, type C-1, using 20mm graded mechanically crushed stone aggregate, 75mmthick as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5 cms deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen and two parts of heated coarse sand (by volume), all as specified. Note:- The unit rate include for use of form work (straight or curved). |
47 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
48 | Mat finish, premium quality, joint free (edge cut), coloured/ printed ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11sqm but not exceeding 0.18 sqm, as in floors etc. set and jointed in neat cement slurry and including 15mm thick bedding layer in cement mortar (1:6) including necessary cutting and waste as per site requirement pointed in white or coloured cement to match complete all as specified and directed. Size/Shade/Colour of tile shall be approved by the AGE(I). |
49 | Machine cut kota stone slab flooring 20-25 mm thick of size not less than 550 mm X 550 mm as per sample kept in GE’s office, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab, as in floor etc, laid over and including 15mm screed layer in cement mortar 1:4, cutting, rubbing, grinding and polishing to achieve mirror finish, laid over PCC subbase complete, all as specified. |
50 | Machine cut kota stone slab flooring 20-25 mm thick as per sample kept in GE’s office, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab,as inin skirting, dados, risers to steps etc, laid over and including 10mm thick rendering in cement mortar 1:4 , cutting, rubbing, grinding and polishing to achieve mirror finish complete, all as specified. |
51 | 20mm thick, Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete laid over and including 20mm screed layer in cement mortar 1:4. complete all as specified and directed. |
52 | Cutting, rubbing/grinding& mirror finish ,rounding of edges of marble/ kota stone/ granite stonecomplete all as specified and directed. |
53 | Glazed ceramic colouredtilesof size450mm x 350mm x7 mm thick as in vertical surfaces , set and jointed in neat cement slurry and pointed with white or coloured cement to match the shade of tile over and including 10 mm thick cement screed in cement mortar 1:3 complete all as specified and directed. Size/Shade/Colour of tile shall be approved by the GE. |
54 | Rendering cement plaster 15mm thick in cement mortar 1:6 on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified. |
55 | Rendering cement plaster 15mm thick in cement mortar 1:4 on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified. |
56 | Supply only liquid water proofing compound, complete all as specified. |
57 | Preparation of wooden surfaces of any description, not otherwise described, over 10cm in width or girthand applying two coats of synthetic enamel paintover a coat of pinkprimer complete all as specified and directed. |
58 | Preparation of old wooden surfaces of any description, not otherwise described, over 10cm in width or girthand applying two coats of synthetic enamel paintcomplete all as specified and directed. |
59 | Preparation ofnewplastered surfaces or un plastered, previously undecorated wall surfaces and applyingtwo coats of cement base paint over one coat of primer, complete all as specified and directed. |
60 | Preparation of steel surfaces of any description, over 10cm in width or girth,not otherwise describedand applying two coats of synthetic enamel paint over a coat of red oxide primercomplete all as specified and directed. |
61 | Preparation of old steel surfaces of any description, over 10cm in width or girth,not otherwise describedand applying one coat of synthetic enamel paint,complete all as specified and directed. |
62 | Preparation of new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper onver one coat of primer over and including a coat of 2 mm thick wall care putty complete, all as specified and as directed by Engr-in-Charge |
63 | Preparation ofplastered or un-plastered,old surfaces of walls and applyingtwo coats of cement base paint, complete all as specified and directed. |
64 | Preparation ofold surfaces of wall by Complete removal of existing treatment andapplying two coats of oil bound distemper over a coat of primer over and including2mm thick wall care putty (applied in two layers), finished smooth with sand paper complete all as specified and directed. |
65 | Wash basins, Vitreous China (Flat white type) size 550mmx400mm, with pedestal, crystal white with and including cutting for and pinning on ends of brackets, 450 mm long PVC connections 15mm size with PTMT coupling nuts at both ends, trap, grating and Union for discharge pipe, waste, chain and plug and porcelain stopper, waste pipe of polythylene of low or high density or PVC of 32mm dia including , 15mm bore cast copper alloy, with capstan heads, chromium plated, fancy type mixer, 32mm dia waste fittings, brass chromium plated with long screwed shanks and fly nuts, flange and bedded in red lead cement and other end fixed, screwed for iron pipe and fixed, completeall as specified. Make: Cat Part No. 1008 of Cera or equivalent in makes mentioned in Appx |
66 | Bib tap, cast copper alloy ,chromium plated, fancy type , screwed for iron pipe or for brass ferrule of 15 mm bore, fixed in repair, complete all as specified and directed. |
67 | Stop valve cast copper alloy, fancy type, chromium plated with long shank and cup (concealed type), with crutch or butterfly handle, screwed both ends for iron pipe or for unionsfor 15mm bore iron pipe or for unions and fixed in repairs complete, all as specified. |
68 | Stop valve/Angle Valve cast copper alloy, fancy type, chromium plated , with crutch or butterfly handle, screwed both ends for iron pipe or for unionsfor 15mm bore iron pipe or for unions and fixed in repairs complete, all as specified. |
69 | PVC connections 15 mm size with PTMT nutsof length 450mm fixed in repair complete all as specified and directed. |
70 | PVC connections 15 mm size with PTMT nutsof length 600mm fixed in repair complete all as specified and directed. |
71 | Brass chromium plated tubular towel rail 20 mm dia, "D" type, 60 cms long between flanges fixed in repairs with and including chromium plated brass brackets, brass screws complete all as specified |
72 | 600x450 mm bevelled edge mirror of slected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plug with chromium plated brass screwed and cup washers. |
73 | PVC valve less, crystal white, syphonic action type flushing cistern 10 litre capacity, superior quality, plunger type, low level, with inlet, ball valve, float and handle, 32 mm dia PVC long bend flush pipe 90cm long and 15 mm dia 600 mm long PVC connection with CP brass coupling nuts and PVC washers at both ends fixed, fixed in repair, all as specified. Make: Cat Part No. 2602 ofCera or equivalent in makes mentioned in Appx . |
74 | Vitreous China bowl urinal flat back, sizeof 465 x 355 x 265 mm white (minimum),with grating and union for discharge pipe complete including providing and fixing plugs, bedding urinalagainst wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; including automatic flushing cistern (PVC) 5 Litre Capacity with brackets, flush pipe, grating and Union for discharge pipe, complete all as specified. |
75 | Vitreous China wash down water closet (pedestal pattern), white including traps, connection to drain or outgoing pipe, flushing pipe, anti-syphonage pipe complete including fittings, PVC white seat cover andchromium plated jet including PVC connection, fixedcompleteprovision of plain cement concrete M-15, type B-I, using 20mm graded crushed stone aggregate,all as specified. Make: Cat Part No. 2008 for EWC, 2308 for seat cover, 2201/B for internal fittings of"Cera" or equivalent makes mentioned in PS. |
76 | G I tubingmedium gradeof 15 mm borewith all fittings and fixtures fixed to wall and ceiling or laid infloor/trenches complete all as specified and directed. |
77 | G I tubingmedium gradeof 20 mm borewith all fittings and fixtures fixed to wall and ceiling or laid infloor/trenches complete all as specified and directed. |
78 | PVC (SWR) 110mm bore (dia) soil, waste and ventilating pipe, singe socketed, in any length with Rubber Ring Joints fixed to walls, including taking down unserviceable pipe, fittings, etc, complete all as directed and all as specified. |
79 | Rotational moulded polyethylene water storage tank 1000 Ltrs capacity four layered (ISI Marked) cylinderical vertical with closed top, hoisted and fixed in position with ball brass valve, high pressure with PVC float valve 20mm dia with polythene float and fly nut, tank nipples with check nuts and washers complete and making connections with existing water supply line complete all as specified. |
80 | Taking down point wiring with aluminium/ copper conductor for light point, socket point/ power point etc. in PVC casing and caping, surface pvc/ steel conduits, wood batten with clips including taking down board any type and size complete with any type of switches, sockets, holders, (batten or pendent type), ceiling rose etc. The light fittings (any type), main switches, distribution board with MCB’s of any capacity and make are to be removed/ replaced if required and all as specified and directed. NOTE: - Existing fan regulator any type (Where required) and electric meters are to be refixed and connected properly where required. |
81 | Point wiring with copper conductor cable multistrand, PVC sheathed 1.5 Sqmm size(two run with colour code RYB) for one light point ,fan point, exhaust fan point,or bell point controlled by one switch including one run of 1.5 Sqmm (as continous earth wire Green)multistrand PVC concealed conduit of approved size and quality ISI marked,including all other required accessories as specified in preamable 1(a) to (q) of section 19 of SSR Part-II under heading "point wiring" fixedon wall/ceiling including sunk cast iron terminal boxes grouting/flushing on wall for mounting fittings like switch,sockets etc covered with 3.00 mm thick plastic laminated sheet top cover of brick masonary/Stone masonary wall complete including cutting,chasing,pinning and making good the disturbed surface by using cement mortar 1:3 complete all as specified and directed by Engr-in-charge.,(Note:-the rate for concealed type point wiring shall deemed to include the cost of cutting,chasing in wall by using electric cutter andmaking good the disturbed surface of wall by providing cement plasterand matching the surface by white wash/colour wash all as per existing finishes complete). |
82 | All as per serial item No "81" above, but for one 3 pin 5 Ampssocket outlet on the same board all as specified and directed. |
83 | All as per serial item No "81" above, but for one 3 pin 5 Ampssocket outlet, independent all as specified and directed. |
84 | All as per serial item No. "81" above but for 3 pin 15 Amps socket out letindependentwith 2.5 Sqmm PVC copper conductor cable and and PVC insulated, unsheathed 2.5 Sqmm stranded copper conductor cable as continuous earth wire, all as specified. |
85 | Switch piano flush type, single pole, one way, 5 Amps, all as specified. |
86 | Switch piano flush type, single pole, one way, 16 Amps, all as specified. |
87 | Socket outlet, 3pin, , 6 amps flush type, all as specified. |
88 | Socket outlet two in one, 3 Pin 5 amps and 15 amps, flush type, all as specified. |
89 | Ceiling rose, 65 mm to 50 mm, two to three terminals, PVC/ Polycarbonate, insulated body fixed on PVC block, all as specified. |
90 | Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings, all as specified. |
91 | Replacement of Sheet metal enclosures for DBs when MCBs to be used, triple pole and neutral, 4 way, double door, 240 volts with 200 Amp rated bus bar completed all as specified. |
92 | Replacement of Sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 8 way, double door, 240 volts with 200 Amp rated bus bar completed all as specified. |
93 | MCB TPN, 63 Amp, 415 Volts, 10 KA all as specified. |
94 | MCB SPN 40 Amp, 240 Volts, 10 KA all as specified. |
95 | MCB SP 6 to 32 Amp, 240 Volts, 10 KA all as specified. |
96 | Replacement of Sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 4 way, double door, 240 volts with 200 Amp rated bus bar completed all as specified. |
97 | Renewal of sub main wiring with two single core PVC insulated cable1100 volts grade with copper strandedRLS conductor of size 4 Sqmm (2 single run) with one continuous FRLS copper earthing lead wire ofsize 4 Sqmm and drawn into PVC conduit/ casing & capping with all fittings/ accessories, junction boxes1 to 4 way 20mm dia, cutting chases, making good in cement mortar (1:3), finishing surfaces to match with existing and connected to common earth dolly including taking down old unservicable submain wiring, complete and as directed. Note :- Two run (each run of 1 RM) of 4 sqmm copper conductor andone RM of earth wire of 4 Sqmm,shall be measured as one RM). |
98 | Basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver., 10 watt LED,6500k, two feet long, with all acessoreis internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable sizeincluding dismantling of unserviceable tube light all as specified and directed. Make: Havell"s Cat Part No. LUMILINEBS10WLED865SPCWH of"Havells" or equivalent in makes mentioned in Appendix |
99 | Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack. 1x20W, 6500K ,230V, connector block etc completewith all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable sizeincluding dismantling of unserviceable tube light all as specified and directed. Make: Havells cat part No. LHEXAWP7IN1W020 or equivalent in Appx |
100 | LED Study Light 5 WATT, decorative ultra slim square profile LED lighting with extruded polycarbonate, environmental friendly, energy efficient ready to use pack including dismantling of unserviceable tube light all as specified and directed. |
101 | Endura Sundown 35 Watt,New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08.. connecting with PVC insulated three core flexible copper conductor of suitable size from ceiling rose to fitting including bracket of suitable size, complete all as specified Make: Havells cat part No. ENDURASUNDOWNSL35WLED765PASYBOPC or equivalent in Appx |
102 | Exhaust fan made of sturdy engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm and making connection with 3 core copper flexible cable of size 23 x .0076 from ceiling rose/ PVC connector to fan complete all as specified. |
103 | Aluminum strip 25x3.15mm fixed with porcelain/PVC saddlesand fixing screws etc including PVC gutties in each one metre length , for roof conductors and down conductors above ground, fixed in reapir , complete all as specified. |
104 | Air termination single pointed aluminum rod 12mm dia and 300mm long, complete all as specified. |
105 | Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexognal .head screw all as specified. |
106 | Mild steel galvanised iron tubing light grade for cable protection as in road crossing, along poles, walls, floors, drain of 40mm size fixed with MS clamps, nuts and bolts required complete all as specified and directed. |
107 | Sand cushioning to under ground cables provided with a layer of sand 8 cms thick before laying the cable and 15 cms thick after laying the cable complete all as specified and directed. |
108 | Sub class "B" bricks for covering to cable laid dry flat, with width equal to length of bricks all as specified and directed. |
109 | XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with multi-standard aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm, 4 core, laid in trenches or passing through pipes, including making necessary connections at both ends, complete all as specified and directed. |
110 | Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC (1:2:4) , type B-I using 20mm graded crushed stone aggregates with 40mm thick cover of RCC M-15, type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixingarrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electricalplate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion. |
111 | Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron strip 25X4 mm size (as earth lead strip), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 40 mm bore including provn of concrete pit in plain cement concrete M-15 type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of rainforced cement concrete M-15 reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixingarrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electricalplate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion. |
112 | Deduct Credit Amount as per Schedule of credit as details given on Srl Page No 28 of tender doucments. |