Comprehensive Maintenance To Bldgs Of Group Iv Units Loc At Eme Bn Asc Bn Fd Hosp Adu And Ord Det At Lms, leimakhong-Manipur

Military Engineer Services-MES has published Comprehensive Maintenance To Bldgs Of Group Iv Units Loc At Eme Bn Asc Bn Fd Hosp Adu And Ord Det At Lms. Submission Date for this Tender is 21-05-2024. Building Work Tenders in leimakhong Manipur. Bidders can get complete Tender details and download the document.




Tender Notice

43268596
Corrigendum : Comprehensive Maintenance To Bldgs Of Group Iv Units Loc At Eme Bn Asc Bn Fd Hosp Adu And Ord Det At Lms
Open Tender
Indian
Manipur
leimakhong
21-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Comprehensive Maintenance To Bldgs Of Group Iv Units Loc At Eme Bn Asc Bn Fd Hosp Adu And Ord Det At Lms

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 13-May-2024 CORRIGENDUM NO 1 BOQ 21-05-2024
2 18-May-2024 CORRIGENDUM NO 2 Other 21-05-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 60000.0 /-
Tender Value
INR 30 Lakhs /-

Attachment

FileName File Description File Size
4b0d1aa9-022f-4e61-8c15-cdde9236416e.html Tender Notice 0 KB
BOQ_729503.xls Tender Document 0 KB
TENDERDOCUMENTS.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: COMPREHENSIVE MAINT TO BLDGS OF GROUP-IV UNITS/ LOC AT EME BN, ASC BN, FD HOSP, ADU AND ORD DET AT LMS.
Sl. No. Item Description
1Schedule "A"
2Taking down Chowkats or frames with shutters (w/o taking of shutters from the frame) exc. 1.5 Sqm but n.exc. 4 Sqm complete all as specified and directed.
3Taking down Chowkats or frames with shutters (w/o taking of shutters from the frame) area n. exc 1.5 Sqm complete all as specified and directed.
4Taking down shutter of any description and removing frome siteexc. 1 Sqm & n. exc. 2 Sqm each leaf complete all as specified and directed.
5Taking down shutter of any description and removing frome siten exc. 1 Sqmeach leaf complete all as specified and directed.
6S&F II nd class hard wood (haldu/ hallock) plain, solid, straight chowkats& frames , wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and directed.
7S&F30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, both face is covered with decorative face veneer with lipping/frame to match complete all as specified and directed.
8S/F 2nd Class H.W. Skeleton shutter 35 mm thick open rebated & prepared to receive glass, gauze, etc. divided into squares with plain chamfered or rounded & rebated sash bars (of any nos)as spd in SSR Pt-I Sec 8 Cl. 8.24.(a) as per specification complete all as specified and directed.
9S/F 2nd Class H.W. Skeleton shutter 35 mm thick open rebated & prepared to receive glass, gauze, etc. divided into squares with plain chamfered or rounded & rebated sash bars (of any nos)as spd in SSR Pt-I Sec 8 Cl. 8.24.(b) as per specification complete all as specified and directed.
10S&F solid PVC door frame of size 50mm x 47mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube in opening as per specification & drawing complete all as specified and directed.
11S&F factorymade solid pannel PVC door shutter 30mm thick consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with neat moulded plan colour PVC "C" channel having a PVC sheet strips of 20mm width stuck in side with solvent cement for styles and plain colour PVC sheets for top rails, lock rail and bottom rail on eithor side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheets to be fitted in the MS frame welded/sealed to the stiles, and rails with suitable PVC sheet bedding and jointed together with solvenet cement, supply and fixing in the frame at site as per specification complete all as specified and directed.
12S&F in repair Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
13M and L two coat of synthetic enamel painting to woodensurfaces (frame & shutter) over a coat of primer incl preparation of wooden surface.Surfaces of any description, not otherwise descri-bed, over 10cm width or girth complete all as specified and directed.
14Supply and fix for aluminium powder coated three track sliding window with two glazed shutters, one 4mm thick float glass ordinary quantity and one shutter of stainless steel wire mesh 0.36mm nominal dia of wire & average width of aperture 1.40mm including good quality of bearing handle, locks, PVC rubber lining, rollers etc complete all as specified and as directed. Catlouge numbers of Jindal company or equivalent make as specified. Sections of Jindal company : Three track bottom – 20957, Three track top/vertical – 20958,Handle – 20606, Interlocking – 20605, Top and bottom – 20604.
15S&F ventiltors/ louvers with parttially guaged shutter using 5 mm thick x 10 cm wide frostedglass strips andfollowing aluminium powder coated sections conforming to catalogue of "JINDAL" or of equivalent make and rubber beading etc all as directed.(a) SP :20048 (b) Glazing clips :19352
16S & F aluminium anodised Hasp and staple 75mm , safety type,mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed.
17S&F 100 mm long Aluminium anodised barrel tower bolt of extruded section complete all as specified and directed.
18Supply and fix Extruded aluminium alloy handles, 100 mm long fabricated type., anodised complete all as specified and directed.
19S&F 100 mm long Stainless Steel butt hinges medium weight colld rolld complete all as specified and directed.
20S&F 150mm aluminium anodised of extruded section barrel tower bolts complete all as specified and directed.
21S&F 200mm aluminium anodised of extruded section barrel tower bolts complete all as specified and directed.
22S&F 150mm long alumiunium handles cast type anodised complete all as specified and directed.
23S&F 140mm long floor door stopper of brass body and tongue with had drawn steel spring complete all as specified and directed.
24S&F aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolt of extruded section or cast aluminium alloy and fixed 300mm long complete all as specified and directed
25S&F in repairs 100 mm longStainless Stee butt hinges medium weight colld rolld complete all as specified and directed.
26S&F in repairs150 mm long Aluminium anodised barrel tower bolt of extruded section complete all as specified and directed.
27Supply and fix in repairs Extruded aluminium alloy handles, 150mm long fabricated type., anodised complete all as specified and directed.
28S&F in repairs 300 mm long Aluminium allow anodised sliding door bolt with hasp staple (bolt type ) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section or cast alu allow complete all as specified and directed.
29Supply and fix in repairs floor door stopper of aluminium body and tongue anodised with hard drawn steel spring fixed in floor over all length of cover plate 150mm complete all as specified and directed.
30S & F in repairs fancy typedecorative Draparyrod of 20mm dia for window and doors with curtain rings and decorative doom holders fixed to wall with screw complete all as specified and directed.
31S&F in Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
32Hacking out old broken glass (any thickness, size, quality or description) frommetal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed.
33S/F 3 mm thick sheet glass ordinary quality & glazing with oil putty in squares n. exc. 0.5 Sqm in each pane complete all as specified and directed..
34S/Ffigured glass 3 mm thick, pin head type & glazing with oil putty in squares n. exc. 0.5 Sqm in each pane complete all as specified and directed.
35Supply only 5.5 mm thick sheet glass, selected quality, in square exc 0.5 Sqm each pane including solar control film 25 micron reflective type over it complete all as specified and directed.
36S&F door closer (aluminium extuded body section) hydreulically regulated, ,designation No 1 universal type, suitable for door shutters up to 700mm in width and of wieght not more than 35Kg complete all as directed.
37S&F in repairs vitreous china European type wash down water closet pan (Pedestal pattern) of white colour including plastic water closet seat black closed pattern with flat bottom (with MS or CP hinging device) and fixing bolts, P or S trap, necessary inlet and outlet connections including syphonic action type low level PVC flushing cistern of 10 lit capacitywhite in colour and PVC flush pipe 32mm dia complete all as specified and directed.
38Supply and fix in repairs vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests Complete all as specified and directed
39S&F in repair PVC flushing cistern 10 ltrs capacity ISI marked incl PVC down pipe and connection etc all complete in repairs complete all as specified and directed..
40S&F in repairs plastic water closet seat cover black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminum hinging device complete all as specified and directed.
41Supply only Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern complete all as specified and directed.
42S&F Vitreous china coloured Wash Hand Basin (Oval Shape) 580mm X 450mmfixed in repairs including 15 mm pillar cock cast copper alloy CP, 15mm cast copper stop valve, 32 mm brass CP waste fitting & 15 mm PVC connection pipe 450 mm long fixed in repairs complete all as specified and directed.
43Supply and fix in repairs Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and unionfixed in repair complete all as specified and directed.
44S&F in repair for stop cock copper alloy CP screwed down high pressure with crutch or butterfly handle screwed both ends for iron/pipe or for union and fixed 15 mm bore in repairs complete all as specified and directed.
45S&F in repair bib taps cast copper alloy with crutch or butterfly handle, chromium plated fancy type screwed down, screwed for iron pipe or for brass ferrule and fixed in repairs complete all as specified and directed.
46S&F in repairsHealth faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed.
47S&F in repairs 32/50mm dia PVC waste pipeforkitchen sink , WHB , Urinal etc complete all as specified and directed.
48Supply and fix in repair 15mm bore piller taps of cast copper with capstan head CP screwed down high pressure with or without lettered hot and cold with long screwed shank and fly nut for iron pipe and fixed in repairs complete all as specified and directed.
49S&F in repair Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed.
50S&F PVC connections 15 mm size with PTMT nuts to length 450 mm in repairs complete all as specified and directed.
51S&F in repair Brass, Chromium plated, Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed.
52S&F in repairs Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed.
53Supply and fix in repairs brass Chromium plated shower roses 125mm sizewith or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed.
54S & F 600mmx450mm beveled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed.
55Taking down steel tubing and connections including cleaning for re-fixing or removal to store of 15 mm bore complete all as specified and directed.
56Taking down steel tubing necessary fittings connection etc for 20 mm bore pipe complete all as specified and directed.
57S&F GI tubing 15mm dia medium gradegalvannised with all fitting &fixed complete to walls & ceiling or laid in floors complete all as specified and directed.
58S&F 20mm thick GI Tubing medium grade galvanised with all fitting and fixed complete all as specified and directed.
59S&F in repair PVC (SWR) floor trap, plain with grating including jointing with solvent cement dia of outlet in 75mm complete all as specified and directed.
60S&F in repairs 110mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints laid in trenches or in floors.
61S&F in repairs 75mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints laid in trenches or in floors.
62S&F in repairs 110mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints laid in trenches or in floors complete all as specified and directed.
63S&F in repairs 75mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints fixed to walls.
64S&F in repairs PVC (SWR) bends of any radius of 110mm dia. With oval and access door complete all as specified and directed.
65S&F in repairs PVC (SWR) bends of any radius of 75mm dia complete all as specified and directed.
66S&F in repairs PVC (SWR) branch piece (single ‘Y’) equal or unequal for 110mm dia PVC pipe complete all as specified and directed.
67S&F in repair PVC(SWR) branch piece (single ‘Y’) equal or unequal for 75mm dia PVC pipe complete all as specified and directed.
68S&F in repair for PVC (SWR) junction (single ‘T’) with access door for 110mm dia pipe complete all as specified and directed.
69S&F in repairfor PVC (SWR) junction (single ‘T’) with access door for 75mm dia pipe complete all as specified and directed.
70S&F in repairfor PVC (SWR) vent cowl suitable for 110mm dia PVC pipe complete all as specified and directed.
71S&F in repairfor PVC (SWR) vent cowl suitable for 75mm dia PVC pipe complete all as specified and directed.
72Supply and fix in repairs ball valves high pressure of PTMT with epoxy coated aluminium rod and highdensity plastic ball screwed for iron pipe and fixed in repairs of pipe 20 mm dia.
73S/F in repair sinks made of stainless steel of 1 mm thick kitchen sink with plug washers and wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495 x 420 mm bowl size 410 mm x 330 mmx 160 mm complete all as specified and directed.
74Dismantling Water Tanks & removing from site, capacity of tanks exc 250 litres & n. exc. 500 Litres capacity each complete all as specified and directed.
75Dismantling Water Tanks & removing from site, capacity of tanks 500 ltr and n exc 1000 ltr complete all as specified and directed.
76S/F Rotational moulded polyethelene water storage tanks (cylindrical, vertical with closed top) hoisted & fixed in position all as specified in SSR Pt-I, 500litre capacity complete all as specified and directed.
77S/F Rotational moulded polyethelene water storage tanks (cylindrical, vertical with closed top) hoisted & fixed in position all as specified in SSR Pt-I, exc 1000 ltr capacity complete all as specified and directed.
78Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position, Capacity exc 250 litrs n exc 500 litrs, cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc complete all as specified and directed.
79Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position, Capacity exc 500 litrs n exc1000 litrs and cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc complete all as specified and directed.
80Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
81S&F forexposed GI powder coated snap grid frame work for false ceiling of grid size 600X600mm comprising of wall /cleat angle of size 24X 38X0.70mm with 4mm dia GI providing 4mm thick "E" board in ceiling with galvanised iron snap frame of "T" Section 24x38x0.70mm wall/cleat angle 25x25x0.35mm thick and hanging with 2mm GI wire all fixed arrangement will be done as per manfraxture instruction including two coat of oil bound distemper and one coat of primer complete all as directed.
82S&F6mm thick ply wood grade BWR (type BB) fixed with nails to the timber frame work asin wall complete all as specified.
83M&L for RAJSHRI brand insulated PVC wall panelling consisting of PVC insulated panels having wall thickness of 2mm (+or -0.2) PVC sheet opf density 600 Kg /CbmManufactured by an ISO-9001-2015 certified company, and the desired thickness of EPS ( Dependent on the insulation required) screwed into the wall using screws of adequate length. The screws shall be placed at a distance of 150mm and shall be 25mm from theedge of the insulated panelon all four sides of the panel. The PVC strips of 5mm ( + or - 0.25) thick PVC sheet of width 75mm feathered at the edges shall be stuck using solvent cement adhesive at the places where two panels are joined, so as to cover the screw of both panels, using solvent cement 900heat bent strips of 5mm thick PVC sheets of width 75mm x75mm feathered at the edges shall be stuck at wall joints / pillars etc. complete as per direction of ENgineer -in- Charge, manufactures specification and drawings complete all as specified and directed.
84M&L forSecond class hardwood Weather boarding, clean sawn, thickness 20mm to 25 mm and rebated on thick edge to give20mm laps and fixed complete all as specified and directed.
85Material and labour for 0.90mm thick decorative laminate type 1 of surface finish, colour, pattern and size as approved, fixed with approved adhesive as per manufacturer’s instructions on horizontal and vertical surfaces etc. complete all as specified and as directed.
86Material and labour for 4mm thick one side decorative group match veneer complete all as specified and as directed.
87Dismantling of timper scantling40 sq .cm and over in section,in any position complete all as specified and directed.
88M&L for second class hard wood in scantling wrought, timber framed & fixed complete all as specified and directed.
89Fixing only second classhard wood in scantling clean sawan , timber framed & fixed complete all as specified and directed.
90Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
91S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, including one coat shop primer complete all as specified and directed.
92M & L two coat of synthetic enamel paint on steel surfaces over one coat of zinc primer including preparation of new steel surfaces exceeding 10 cm width or girth
93Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital orsimilarpattern roof coverings ,any description and in any position complete all as specified and directed.
94M&L for Pre- painted galvalume aluminum zinc coating GI based semi corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr -in- Charge.
95S&F Galvanised, corrugated mild steel sheeting pf 0.63mm thickness with two corrugations side lap, fixed with L type or J type or cranked hook bolts, in roofs, walls etc. with grade of zinc coating 275 complete all as specified and directed.
96S&F galvanized plain mild steel sheeting 0.63 mm thick in ridges, hips, valley gutters, drip & straight flashings (length and firth as fixed ) with grade of zink coating 275 complete all as specified and directed.
97M&L for filleting in any position & to any shape, sectional area exc.25 but n. exc. 50 sqcm. In CM 1:4 including all mitres , stops etc, complete all as specified.
98Demolition of brick work or stone/ boulders masonry, built in cement mortar including all quoins, arches, pillars etc. but excluding ashlars facing, dressed stone work and precast concrete articles complete all as specified and directed.
99M&L for brick work with subclass "B" brick straight or curved on plan 6m mean radious built in CM (1:6) complete all as specified and directed.
100M&L brickwork with sub- class ‘B’ bricks, straight or curved on plan to any radius built in cement mortar 1:4 using old size bricks as in half brick thick wall complete all as specified and directed.
101Demolition of cement concrete in ground floors and paving not exc 15cm thick (below or above ground level) un-reinforced complete all as specified and directed.
102M&L for 75mm thick PCC (1:4:8) type C2 (using 40mm graded aggregate) as in sub base/flooring/ paving complete all as specified and directed.
103M&L for 75mm thick PCC (1:3:6) type B2 (using 20mm graded aggregate) as in plinth protection/hard standing, finishing cementconcrete surface even and smooth without using extra cement complete all as specified and directed.
104Taking down cement plaster on stone / Brick walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
105M&L for rendering 10mm thick plaster on fair faces of brick work or concrete surfaces (1:6) finished the surface even and Smooth without extra cement complete all as specified and directed.
106M&Lfor rendering in CM 1:4 with15mm cement plaster with water proofing compound @ 2% by weight of cement or as per manufacture"s instrs having smooth and fair finish all as specifiedand directed by engineer - in - charge Note :- (1) Use ofDimapur Sand to plaster. (2) WPC pdr shall be measured and paid separately.
107Supply only integral water proofing compound complete all as specified and directed.
108M&L for rendering 5 mm thick plaster on ceiling concrete surfaces as in CM (1:3) finished even & Smooth without using extra cement complete all as specified and directed.
109M&L for three coat of white wash to newly plastered surfaces of on ceiling complete all as specified and directed.
110M&L for two coats of oil bound distemper over a coat alkali resistent primerto newly plastered surfaces of walls including preparation of surfaces complete all as specified and directed.
111M&L for preparing newly plastered surfaces of walls and applying two coats of cement base paint over a alkali resistent primer complete all as specified.
112Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
113M&L for colored Non Skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or colored cement to match, including 15 mm thick screed bed or bedded layer in cement mortar 1:6 for laying floor finish complete all as specified and directed.
114M&L for colored glazed ceramic tiles (300mm x450mm) x 7 mm thick on vertical surfaces set and jointed in neat cement slurry and pointed in white or colored cement to match including 10 mm thick backing coat in cement mortar (1:4) on stone masonry surfaces or surface other than fair face of brickwork or on one side of lathing to receive /fixing dado/ skirting tile complete all as specified and directed.
115M&L for Non - skid Ceramic colour tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over 15mm thick screed bed in CM 1:6etc set and jointed in neat cemet slurry and pointed in white or coloured cement to match complete all as specified and directed.
116Dismantling of stone slab in any description or thickness, laid bedded jointed in any morter complete all as specified and directed.
117Material and labour for Granite(of any type) 18 to 20 mm thick work (table rubbed and polished) in steps, jambs, pillars, window- cills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match withshade complete all as specified and directed.
118Material and labour for bitumen patches on roof sheet to arised the leakage seapakge complete all as specified and directed.
119Taking down carefully copper / Aluminium point wiring including (light, fan, socket or power complete fittings, such as switches, ceiling roses, pendant holders, Batten holders, shades conical fan regulators, light or power sockets etc) removing materials from site and making good disturbed surfaces of walls roofs etc complete all as specified and directed.
120M&L for point wiring for one light or one fan point controlled by one switch with using 1.5 Sq mm (nominal area) stranded copper conductor single core PVC insulated & unsheathed cable 1100 volts grade in and inclPVC casing and capping of suitable size fixed on surface all as directed with using new sunken type pressed steel box/terminal boxes for mounting fittings/junction boxes not less than 1.6 mm thick duly painted with two coats of black bituminous paint over a coat of red oxide primer with and incl all accessories and using 1.5 Sq mm (nominal area) stranded copper conductor single core conductor PVC insulated & unsheathed cable as in earth wire connected to commen earth dolly complete all as specified and directed.Make PVC cable .Havells/Finolex/Polycab Note : (i)The quoted rates shall be deemed to be inclusive for fixing the PVC casing caping to surface with using PVC of covering sunken boards /terminal boxes/junction boxes of any shape and size with 3 mm thick suitable GI screws and cup washers. (ii)Fititngs like switches, sockets, regulators lamp holders light fittings shall be measured and paid appropriate item of schedule ‘A’ (iii) The contractor shall be responsible for doing point wiring as per the instruction of concerned JE(E/M) and AGE(E/M). Being maintenance work Contractor shall carry out single point wiring or associated work as per the direction of concerned JE(E/M). Delay in any work more than of 3 days after allocation will invite recovery at the double rate of quoted rate. Contractor shall depute a team of electrician and helper on daily basis at E/M complaint cell to carry out maintenance within stipulated time.without fail One light point controlled by one, one way switch
121One Fan point controlled by one one/way switch complete all as specified and directed.
122One 3 pin 5 Amps socket outlet on same board with other switch complete all as specified and directed.
123One 3 pin 5 Amps socket outlet on independent board with cable of 1.5 sqmm size complete all as specified and directed.
124One bell point controlled by one way switches complete all as specified and directed.
125All as per item No. 119 above but using 2.5 Sqmm PVC insulated, unsheathed cable for one 3 pin socket outlet 15 Amps on independent board.
126All as per item No.119 above but wiring with 4 sqmm multistranded copper conductor unsheathed and 4 sqmm copper conductor unsheathed cable as earth continuity conductor for one 3 pin 15 Amps socket outlet point on independent board complete all as specified and directed.
127Material and labour for point wiring for one light point or one fan pointor one fan point controlled by one switch with using 1.5 Sq mm (nominal area) stranded copper conductor single core, PVC insulated & unsheathed cable, 1100 volts grade inconcealed PVC conduit (medium grade) of 20mm dia/as exist on siteall as specified and directed with using new sunken type Pre - coated 120 GSM (Gram Per m²) GI sheet pressed steel boxincluding 3 mm thick plastic laminated sheet top cover with 4 Nos SS screw and washer for mounting of paino type switches, sockets and fan regulators etc incl all accessories and using 1.5 Sq mm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable (In green colour) as in earth wire connected to common earth dolly complete all as specified and directed. Make PVC cable .Havells/Finolex/Polycab Note : (i)The quoted rates shall be deemed to be inclusive of sunction boxes/modular cover plate andcutting chases in brick walls/pillars etc for concealing the depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the portion of point wiring atfor covering / fix sunken boards/terminal boxes/junction boxes of any shape and size . (ii)Fittings like switches sockets regulators, lamp holders light fittings shall be measured and paid for seperatly of cencern item of Sch’A’. The contractor shall be responsible for doing point wiring as per the instruction of concerned JE(E/M) and AGE(E/M). Being maintenance work Contractor shall carry out single point wiring or associated work as per the direction of concerned JE(E/M). Delay in any work more than of 3 days after allocation will invite recovery at the double rate of quoted rate. Contractor shall depute a team of electrician and helper on daily basis at E/M complaint cell to carry out maintenance within stipulated time.without fail One light point controlled by one one/way switch.
128One Fan point controlled by one one/way switch complete all as specified and directed.
129One 3 pin 5 Amps socket outlet on same board with other switch complete all as specified and directed.
130One 3 pin 5 Amps socket outlet on independent board with cable of 1.5 sqmm size complete all as specified and directed.
131One bell point controlled by one way switches complete all as specified and directed.
132All as per item No. 126 above but using 2.5 Sqmm PVC insulated, unsheathed cable for one 3 pin socket outlet 15 Amps on independent board complete all as specified and directed.
133All as per item No.126 above but wiring with 4 sqmm multistranded copper conductor unsheathed and 4 sqmm copper conductor unsheathed cable as earth continuity conductor for one 3 pin 15 Amps socket outlet point on independent board complete all as specified and directed.
134M&L for point wiring for one light or one fan point controlled by one switch with using 1.5 Sq mm (nominal area) stranded copper conductor single core PVC insulated & unsheathed cable 1100 volts grade in and inclPVC casing and capping of suitable size fixed on surface all as directed with using new sunken type pressed steel box/terminal boxes for mounting fittings/junction boxes not less than 1.6 mm thick duly painted with two coats of black bituminous paint over a coat of red oxide primer with and incl all accessories and using 1.5 Sq mm (nominal area) stranded copper conductor single core conductor PVC insulated & unsheathed cable as in earth wire connected to commen earth dolly complete all as specified and directed.Make PVC cable .Havells/Finolex/Polycab Note : (i)The quoted rates shall be deemed to be inclusive for fixing the PVC casing caping to surface with using PVC of covering sunken boards /terminal boxes/junction boxes of any shape and size with 3 mm thick suitable GI screws and cup washers. (ii)Fititngs like switches, sockets, regulators lamp holders light fittings shall be measured and paid appropriate item of schedule ‘A’ (iii) The contractor shall be responsible for doing point wiring as per the instruction of concerned JE(E/M) and AGE(E/M). Being maintenance work Contractor shall carry out single point wiring or associated work as per the direction of concerned JE(E/M). Delay in any work more than of 3 days after allocation will invite recovery at the double rate of quoted rate. Contractor shall depute a team of electrician and helper on daily basis at E/M complaint cell to carry out maintenance within stipulated time.without fail One light point controlled by one one/way switch.
135One Fan point controlled by one one/way switch complete all as specified and directed.
136One 3 pin 5 Amps socket outlet on same board with other switch complete all as specified and directed.
137One 3 pin 5 Amps socket outlet on independent board with cable of 1.5 sqmm size complete all as specified and directed.
138One bell point controlled by one way switches complete all as specified and directed.
139All as per item No.133 above but wiring with 2.5 sqmm multistranded copper conductor unsheathed and 2.5 sqmm copper conductor unsheathed cable as earth continuity conductor for one 3 pin 15 Amps socket outlet point on independent board complete all as specified and directed.
140All as per item No.133 above but wiring with 4 sqmm multistranded copper conductor unsheathed and 4 sqmm copper conductor unsheathed cable as earth continuity conductor for one 3 pin 15 Amps socket outlet point on independent board complete all as specified and directed.
141S & F in repairswitch piano Modular type single pole one way 6 Amp 240 Volts complete all as specified and directed.
142S & F in repairswitch piano Modular type single pole one way16 Amp 240 Volts complete all as specified and directed.
143S & F in repair socket only 6 Amps 2 in 1 Socket with Shutter Modular type 240 Voltcomplete all as specified and directed.
144S & F in repair socket only 6/16 Amps Twin SocketModular type 240 Volt complete all as specified and directed.
145S & F in repair in repair Bell push switch Modular type single pole one way10 Amp 240 Volts complete all as specified and directed.
146S & F in repair in repair Fan Regulator 2M FSC Modular type 240 Volts complete all as specified and directed.
147S & F in repair ceiling rose PVC polycarbonate isolated body 63.5x20 mm three terminalcomplete all as specified and directed.
148S & F in repair lamp holder PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
149S & F in repair sub main wiring using two single core 6 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing in and including PVC Casing Caping/PVC Conduit or in existing concealed conduit(as required & directed by Engr-in-Charge)accessories like bends, tee, etc fix on wall and ceiling and connecting to earth dolly and including 6 Sqmm earth wire, PVC insulated & unsheathed all as directed.
150All as above item No.149 but using 4 Sqmm cable for phase and neutral and 4 Sqmm for earth wire. Note:(point wiring):The contractor shall be responsible for doing point wiring as per the instruction of concerned JE(E/M) and AGE(E/M). Being maintenance work Contractor shall carry out single point wiring or associated work as per the direction of concerned JE(E/M). Delay in any work more than of 3 days after allocation will invite recovery at the double rate of quoted rate. Contractor shall depute a team of electrician and helper on daily basis at E/M compaint cell to carry out maintenance within stipulated time.without fail
151S & Fin repair Concealed Galvanised (GI) metalflush Boxes Modular 3 module concealed and making good the disturbed surface by white cement&Existing color of bld distamper complete andall as directed by Engr-in-charge.
152S & Fin repair Concealed Galvanised (GI) metal flush Boxes Modular 4 module concealed along with white cover plate and making good the disturbed surfaceby white cement&Existing color of bld distamper complete andall as directed by Engr-in-charge.
153S & Fin repair Concealed Galvanised (GI) metal flush Boxes Modular 6 module along with white cover plate concealed and making good the disturbed surfaceby white cement & Existing color of bld distamper complete andall as directed by Engr-in-charge.
154S&fix in repair 5 Amps Socket only3 Pinflush type complete all as specified and directed.
155S&f in repair 15 Amps Socket only3 Pinflush type complete all as specified and directed.
156S & F in repair 15 Amps Switchflush type complete all as specified and directed.
157S & F in repair switchsocket combination 2 in 1, 3 pin, 5and 15 Amps flush type universal 240 Volt complete all as specified and directed.
158S & F in repair switch socket combination3 pin 16 Amp 2flush type complete all as specified and directed.
159S & F in repair switch piano flush type single pole one way 5 Amp 240 Volts complete all as specified and directed.
160S & F in repair switch piano flush type single pole two way 5 Amp 240 Volts complete all as specified and directed.
161S&fix in repairmodular switch one way 6 Amps 1 module 240 Volts complete all as specified and directed.
162S & F in repairmodular switch one way 16 Amps 1 module 240 Volts complete all as specified and directed.
163S & F in repairmodular switch two way 6 Amps 1 module 240 Volts complete all as specified and directed.
164S & F in repairmodular bell push way 6 Amps 1 module240 Volts complete all as specified and directed.
165S & F in repairmodular socket outlet 6A 3 pin 2 module 240 Volts complete all as specified and directed.
166S & F in repairmodular socket outlet 6A/16 5 pin 2 module 240 Volts complete all as specified and directed.
167S & F in repairmodular fan regulator 120W-2 module 240 Volts complete all as specified and directed.
168S & F in repair Bell push flush type single pole5 Amp 240 Volts complete all as specified and directed.
169S & F in repair Bell ding dong type, one way, 240 volts, AC, ISI marked complete all as specified and directed.
170S & F in repair ceiling rose in replacement surface bakelite three terminal 65 x 50 mm three terminal 250/230 volts ISI marked complete all as specified and directed.
171S & F in repair stright/Angle bulb holder pvc bodycomplete.Make: Anchor, kolors, materialto be supplied as per demand of qty is ordered by Engineer -in- charge as per site requirement.
172S & F in repair in Stepped/socket type electronic fan regulator heavy duty typeA/C 240 V complete all as specified and directed.
173S & F in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed
174S & F in repair TPN DBs Vertical type 4 way DB 415 volt with provision for FP MCB as incomer and MCB SP as outgoing complete all as specified and directed.
175S & F in repair sheet metal enclosure for single pole and neutral 12 way DB 240 voilts, 100 Amp rated bus bar. complete all as specified and directed.
176S & F in repair sheet metal enclosure for single pole and neutral 08 way DB 240 voilts, 100 Amp rated bus bar complete all as specified and directed.
177S & F in repair sheet metal enclosure for single pole and neutral 04 way DB 240 voilts, 100 Amp rated bus bar complete all as specified and directed.
178S & F in repair single pole and neutral enclosure with a two pin and earth plug and socket complete with one single MCB SP 20 Amps complete all as specified and directed.
179S & F in repair MCB SP 5 to 32 Amps 10KA "C" curveand240 volts current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
180S & F in repair MCB SPN 32 Amp, 10 KA, 240 Volts complete all as specified and directed.
181S & F in repair MCB SPN 40 to63 Amp 240 Volts complete all as specified and directed.
182S & F in repair MCB SP & N up to100 Amp 240 Volts complete all as specified and directed.
183S & F in repair MCB four pole up to80 Amp 415 Volts complete all as specified and directed.
184S & F in repair MCB (Four pole)100 Amp 415 Volts v
185S & F in repair MCCB 100 Amp 16 KA complete all as specified and directed.
186M&L in repair for Earthing complete as per electrical plate NO.3 of MES SSR Part I with galvanised steel plate earth electrode 600 mm x 600mm x 6 mm burried directly in ground in a pit of depth not less than 2.25 metre below ground level with the top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to and incl galvanised iron or steel earth lead wire 4 mm dia by mneans of bolts, nuts, check nuts and washers of galvanised iron or steel earthing wire protected by galvanised iron or steel pipe 15 mm dia light grade and connected to main switch board or main control board watering pipe shall be 20 mm dia GI medium grade incl excavation and earth work in any type of soil, PCC pit, CI Frame, RCC covers complete all as specified and directed.
187S & F in repair PVC rectangular block for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 100mm x 100mm x 50 mm complete all as specified and directed.
188All as per serial item No. 187 above but for size 175x100x50 mm deep complete all as specified and directed.
189All as per serial item No. 187 above but for size 200x150x50 mm deep complete all as specified and directed.
190All as per serial item No. 187 above but for size 250x200x50 mm deep complete all as specified and directed.
191All as per serial item No. 187 above but for size 350x200x50 mm deep complete all as specified and directed.
192S & F in repair single phase electronic meters temper proof LCD display with polycarbonate cover 230 V,10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH Class 1 complete all as specified and directed.
193S & F in repair of PVC conduit size 25mm Rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories including chase cutting such as couplers, lock nuts, saddles, pipe hooks complete all as specified and directed.
194Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.;and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and directed.
195S & F in repair LED light fitting mirror type with high out put diffuser 2 feet,10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size completecomplete all as directed by Engr-in-charge.
196S & F in repair LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light 20W connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as directed by Engr-in-charge.
197S & F in repair LED lights fitting 1x 20W, 220V, ACLED Batten with Opal Diffuser, IP20, Inbuilt Motion Sensor based Auto Dim/Brightness decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as directed by Engr-in-charge.
198S & F in repair LED street light fitting 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, including 600mm long bracket with fastner bolt nut and washer for fix in wall complete all as specified and directed.
199S & F in repair LED light fittings small 6 watt round/square type white/yellow complete with choke/driver complete all as specified nd as directed
200S & F in repair recess mounted down lighter 12 Watts complete all as specified and directed yellow/white AS Per Sample complete all as specified and directed.
201S & F in repair LED bulbLamp 09/10Watts Retrofit B22 holder type base wth polycorbonate diffuser and alluminiun heat sink complete all as specified and directed.
202Taking down fan, sealing cable end,dismantling blades and removing fan and blades to E/M store complete all as specified and directed.
203S & F in repair of storage type water heater from wall by disconnecting the electric connection and water inlet/outlet connection from main and repairing the water heater storage type capacity 25 ltrs of any type and make, checking the serviceablity of all parts such as inner vesser, rubber gasket, non return valve, heating element, thermostat etc and refixing the same after replacing of unserviceable parts and assembly completet (considered as one unit) and installing and testing the same as per the direction of Engineer-In-Charge.
204All as per serial item No 204 above but for capacity 50 ltrs complete all as specified and directed.
205S & F in repair of heating elements, 1.5/2 KW any type any size ISI mark 230 volts complete all as specified and directed.
206S & F in repair of thermostat immersion point type 15 Amps, 230250 volts/AC ISI marked complete all as specified and directed.
207S & F in repair ,stainless steel flexible conneciton pipe with brass check nuts complete as per site requirement all as specified and directed by Engineer-In-Charge.
208S & F in repair of indicator lamp assembly for geyser complete all as specified and directed by Engr-In-Charge.
209S & F in repair 15 Amp plug top complete all as specified and directed.
210S & F in repair earth industrial plug top for socket for industrial socket metal glad suitable for 16 Amps metal glad MCB DB complete all as specified and directed.
211S & F in repair industrial socket metal glad suitable for 16 Amps 240 volts metal glad MCB DB complete all as specified and directed.
212S & F in repair 4 sq mm 3 core flexible copper cable for maintenance of geyser, and cooling appliances. (In Role of 90 RM) complete all as specified and directed.
213S & F in repair syphon assembly suitable for 25/50 ltr geyser complete including nuts and washer complete all as specified and directed.
214S & F in repair geyser brass tank for 25/50 ltr geyser complete including nuts, washer, glass wool etc complete all as specified and directed.
215S & F in repair 23/.0076 sq mm 2 core flexible copper cable for maintenance of light/ fan etc complete all as specified and directed.
216M&L for attending complaint of ceiling fan/exhaust fan/air circulator/ cabin fan such as hanging/dismantling/loose connection etc complete all as specified and directed
217S & F in repair of capacitor 4 MFD suitable for any make, type & sweep ceiling fan, exhaust fan, cabin fan & pedestal fan complete all as specified and directed.
218S & F in repair capacitor of 2.5 MFD of ISI marked complete all as specified and directed.
219M & L in repair of rewinding of ceiling fans 1200/1400mm sweep, strip opening and removal of burnt winding wire, rewinding the fans with suitable size of heavy grade (ISI mark ) copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc 6 month waranty period shall given by the dealer/contractor after repair, complete as reassembling taking down and refixing at site and shifting/transporting to wksp including testing complete all as specified and directed.
220M & L in repair of rewinding of Exhaust fan 300 mm sweep, strip opening and removal of burnt winding wire, rewinding the fans with suitable size of of heavy grade (ISI mark )copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc 6 month waranty period shall given by the dealer/contractor after repair, complete as reassembling taking down and refixing at site and shifting/transporting to wksp including testing complete all as specified and directed.
221M & L in repair of rewindingExhaust fan 450 mm sweep, strip opening and removal of burnt winding wire, rewinding the fans with suitable size of of heavy grade (ISI mark ) copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc 6 month waranty period shall given by the dealer/contractor after repair, complete as reassembling taking down and refixing at site and shifting/transporting to wksp including testing complete all as specified and directed.
222M & L in repair of fan bearing 6201/6202 of ceiling fan of any capacity any size all as specified and directed Note: Replacement of bearing to be carried out at E/M complaint cell at LMS only exceptional case where lathe work is required then only fan to be taken at workshop.
223M & L in repair of bearing/bush of exhaust fan/cabin fan/air circulator of any capacity any size all as specified and directed. Note: Replacement of bearing to be carried out at E/M complaint cell at LMS only exceptional case where lathe work is required then only fan to be taken at workshop.
224S & F in repair exahust fan blade 300mm sweep with locking nut complete all as specified and directed.
225S & F in repair ceiling fan blade 1200mm/1400 mm complete all as specified and directed.
226Dismantling and taking out existing unserviceable geyser and deposited to E/M store yard complete all as specified and directed.