Tender For Special Repair To Roof Of Senapati Bhavan (Officer Mess) Of Headquarters 617 (Independent) Air Defence Brigade Camp Under Ge (Army) Vadodara., baroda-Gujarat

Military Engineer Services-MES has published Tender For Special Repair To Roof Of Senapati Bhavan (Officer Mess) Of Headquarters 617 (Independent) Air Defence Brigade Camp Under Ge (Army) Vadodara.. Submission Date for this Tender is 21-05-2024. Building Work Tenders in baroda Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

43268581
Tender For Special Repair To Roof Of Senapati Bhavan (Officer Mess) Of Headquarters 617 (Independent) Air Defence Brigade Camp Under Ge (Army) Vadodara.
Open Tender
Indian
Gujarat
baroda
21-05-2024

Tender Details

Special Repair To Roof Of Senapati Bhavan (Officer Mess) Of Headquarters 617 (Independent) Air Defence Brigade Camp Under Ge (Army) Vadodara. As Per Boq

Key Value

Document Fees
INR 500 /-
EMD
INR 77460.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: SPECIAL REPAIR TO ROOF OF SENAPATI BHAVAN (OFFICER MESS) OF HEADQUARTERS 617 (INDEPENDENT) AIR DEFENCE BRIGADE CAMP UNDER GE (ARMY) VADODARA.
Sl. No. Item Description
1Dismantling of Asbestos Cement (corrugated, semi corrugated etc.) sheets in roof coverings complete all as specified and directed.
2Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
3S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet (manglore pattern type) 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
4S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, and ridge cover, vally gutter fixed with self tapping screws as specified
5S&F 1mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275
6Dismantling of framed work timber scantlings 40 sq.cm and over in section, in any position complete all as specified and directed
7M & L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1998 grade St-240 complete all as specified and directed.
8S&F plates ( plain or chequered), channels. Square cut or notched (ordinary and counter sunk) forming holes, without any attachment using Fe 410 -W (Gde- E- 250) quality- A with reveted bolted or welded attachment all as specified and directed.
9M&L for preparation of new steel surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed
10Demolition of Brickwork or stone/boulder masonary built in cement or cement lime mortar including all quoins, arches,pillars etc. complete all as specified and directed.
11M & L for Brick work with sub class "B" old size bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
12M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces with CM (1:4) finished even and smooth without using extra cement.
13Preparing new plastered surface of walls and applying Premium Acrylic Smooth exterior paint with Silicon additives of required shade: New work (two or more coats applied @ 1.43Ltr/10Sqm over and including priming coat of exterior primer applied @ 2.20kg/10 Sqm) on external walls complete all as specified.
14M & L for complete removal of existing treatement ofwalls by dust proof wall sanding machine/building walls grinding cleaning machine and and applying Premium Acrylic Smooth exterior paint with Silicon additives of required shade, two or more coats applied @ 1.43Ltr/10Sqm over and including priming coat of exterior primer applied @ 2.20kg/10 Sqm) on external walls complete all as specified.
15Taking down cement plaster of any description includingraking out joints, hacking for key, scrubbing down with water and prepare to receive new plastering in internal walls complete all as specified and directed.
16M&L for rendering 10mm thick on other than fair faces of brick work or concrete surfaces of wall with CM 1:6 finished even and smooth withot using extra cement.
17M&L for Preparing new plastered surface of wall and apply two coat of distemper oil emulsion over a coat of alkali resistant primer including 3 mm thick wall care putty on internal walls complete all as specified.
18M & L for complete removal of existing treatement of walls by dust proof wall sanding machine/building walls grinding cleaning machineand applying a layer of 1 to 1.5mm wall care putty on wall and two coat of oil emulsion distemper over a coat of alkali resistantprimer complete .
19Dismantling of wall and ceiling boards (Fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
20S&F Anodised aluminium snap gridwork for false ceiling using 36.5 x 23.5 x 1.5mm main Tee , 23.5 x 23.5 x 1.5mm cross Tee and 25 x25x 1.5 mm angle fixed to wall for ceiling incl necessary supporting hanger with 2mm GI wire for securing frame work to ceiling suspended at 120cm etc.bothway ( size of grid shall be 605 x 605mm) all as specified
21S&F PVC seamless False ceiling fixed on snap gride including all fitting and fixture complete all as specified and directed (Make : Kaka)
22Providing and fixing Gypsum Board 12mm thick in snap grid ceiling fixed with screw as per manufacturers instructions
23Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
24M&L for Nominal mix RCC1:2:4 type B1 ( 20mm graded stone aggragate)for beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
25Use and waste formwork to sides and soffits of floor or roof beams,beam haunchings, girders, bressummers, lintels, cantilevers, shelves including suports over hangs etc.complete all as specified and directed.
26M&L for mild steel TMT steel barsin reinforcement 10mm dia and overcut to length bent to shape required including crankingbindingspirally, hooping for columns hooking ends and binding with and including mild steel wire (annealed)not less than 0.9mm dia complete all as specified and directed.
27M&L for mild steel TMT steel barsin reinforcement5mm dia and over up to 10mm dia in stirupscut to length bent to shape required including crankingbindingspirally, hooping for columns hooking ends and binding with and including mild steel wire (annealed)not less than 0.9mm dia complete all as specified and directed.
28Dismantling of 100mm cast iron or reinforced concrete drain pipes,and taking out of trenches, if required complete all as specified and directed.
29S&F 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls as in waste/soil pipes complete all as specified and directed.
30S&F 110mm PVC (SWR) branch piece, single (Single Y) equal or unequal with access door complete all as specified and directed.
31Taking down carefully copper / Aluminium point wiring including (light, fan, socket or power including complete fittings, such as switches, ceiling roses, pendant holders, Batten holders, shades conical fan regulators, light or power sockets etc) removing materials from site and making good disturbed surfaces of walls roofs etc all as directed.
32Taking down carefully UNSV main switch and DB"s including MCBs of any size make, type and capacity and depositing at site as directed.
33Taking down carefully UNSV Sub main wirng of any size
34M & L for concealed point wiring complete with multistranded copper conductor (FRLS)1.5 Sqmm size PVC insulated unsheathed cable 1100 volt grade, conforming IS 694 & color code in conduit system of wiring, drawn in includingPVC conduit not less than 20 mm dia concealed duly fixed with U-Clips, including cutting chases, finising of slote by means of cement mortormakinggood to the existing surface of the wall complete, sunk in pressed steel terminal boxes of required size not less than 1.2 mm thick factory made and factory painted with top cover 3 mm thick plastic laminated sheet fixed with brass screw and washer with all accessories including single core multistranded copper conductor 1.5 sqmm size solid PVC insulated unsheathed cable (FRLS) as earth wire to common earth and connected to earth dolly drawn in same conduit complete all as specified for:-
35One light point controlled by one one way switch.
36One Fan point controlled by one one way switch.
37One 3 pin 5 Amps socket outlet on same board with other switch.
38One 3 pin 5 Amps socket outlet on independent board with cable of 1.5 sqmm size.
39One light point controlled by two two way switches
40One bell point controlled by one one way switch.
41All as per item No. 34 above but using 2.5 Sqmm PVC insulated, unsheathed cable for one 3 pin socket outlet 15 Amps on independent board
42Taking down U/S FTL and Supply and fixing of4" 18W LEDTube With Batten with system lumen output of 1800 lumens. System Efficacy should be > 115lm/ W. The Luminaire Should have Cool Daylight Color temp of 6500K & CRI>80.Life 40K burning hrs with 70% lumen maintenace. PF>0.95 Surge Protecton of 3KV.All the Photometrical & Electrical parametrs must be supported by LM79-08 test report from NABL Accridiated LAB OR UL, R9 Value > 0. Lamp starting time is not more than 1 Sec. . Make : CG/Phillips/Wipro.
43S/F Modular switch 1 way 6A, 1moduleMake : Anchor/SSK/CONA
44S/F Socket, 6A - 2/3 pin combined 2module, ® Make Anchor/SSK/CONA or its equivalent.
45S/F Socket 6A/16A - 2/3 pin combined 2 module, ®. Make Anchor/SSK/CONA or its equivalent.
46S&F Modular Bell push 6A 1 module Make Anchor/SSK/CONA or its equivalent.
47S & F Bell ding dong type, one way, 240 volts, AC, ISI marked.
48S/F ceiling rose surface bakelite three terminal 65 x 50 mm three terminal 250/230 volts ISI marked. Make : Legrand/Polycab
49S&F Fan step regulator, 120W - 2 module Make Anchor/SSK/CONA or its equivalent.
50S&F Modular White cover plate with frame,1 module
51S&F Modular White cover plate with frame,2 module
52S&F Modular White cover plate with frame,4 module
53S&F Modular White cover plate with frame, 6 module
54S&F Modular White cover plate with frame,8 module
55S&F Modular Metal flush box 1/2 module
56S&F Modular Metal flush box 4 module
57S&F Modular Metal flush box 6/8 module
58Supply and fix ceiling fan complete with blades,down rods,electronic regulator and accessories 230 V ,1200 mm sweep Min air delivery 210 CFM with service value 6.0 BEE 5 star rated with brushless direct current motor (BLDC). Note: Old UNSV ceiling fans will be deposited to AGE E/M office
59S & F MCB SPN 32 Amps 10 KA rupturing capacity. Make Legrand or its equivalent in Schnieder/ABB.
60S&F MCB SP 5 to 40 Amp 240 Volts
61S/F sheet metal enclosure for single pole and neutral 12 way 240 voilts, 100 Amp rated bus bar. IP 43 - IK -09 of Make Legrand or its equivalent in Schnieder/ABB.
62Supply and fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one single MCB SP 20 Amps. Make Legrand or its equivalent in Schnieder/ABB.
63Earthing complete as per electrical plate NO.5 of MES SSR Part I with galvanised steel plate earth electrode 600 mm x 600mm x 6 mm burried directly in ground in a pit of depth not less than 2.25 metre below ground level with the top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to and incl galvanised iron or steel earth lead wire 4 mm dia by mneans of bolts, nuts, check nuts and washers of galvanised iron or steel earthing wire protected by galvanised iron or steel pipe 15 mm dia light grade and connected to main switch board or main control board watering pipe shall be 20 mm dia GI medium grade incl excavation and earth work in any type of soil strata, PCC pit, CI Frame, RCC covers complete.
64S & F wall security light LED type complete including brackets with GI pipe 1.2 mtr, bend to shape and fixing on wall/pole with clamp, nut & bolt complete all as directed and specified by Engr-In-Charge. CAT Part No.LSTO-25-CDL 25watt of Make CG or its equivalent in Phillips/Wipro.
65S & F lamp holder for led bulb PVC/Polycarbonatetype with cord grip including Supply and fixing ofof7 W LED Bulb with system lumen output of 600 lumens. System Efficacy should be > 85lm/ W. TheLamp Should have Cool Daylight Color temp of 6500K . Lamp should be supplied with E27 Holder. Similar to Philips Ace Saver. Make of lamp holder : Legrand/Polycab, Make of LED Lamp : Phillips/CG.
66S&FExhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230 V , 50 Hz RPM 1200 copper winding of sweep 300 mm .
67Supply, Fixing, Testing & Commisioning of 2" 10WMirror LED Batten with system lumen output of 1000 lumens. System Efficacy should be > 85lm/ W. The Luminaire Should have Cool Daylight Color temp of 6500K & CRI>80.Life 40K burning hrs with 70% lumen maintenace. PF>0.95Housing of luminaire should made of die cast alumunium & mounting on two PVC square boxes of size not less than 75mm X 75mm complete including connecting fitting with not less tha 0.5 sqmm 3 core flexible stranded copper conductor wire upto ceiling rose complete all as specified & directed.
68M & L forsub main wiring (on surface conduit) using two single core 4 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing in and including PVC conduit, and accessories like bends, tee, etc fixed on wall and ceiling and connecting to earth dolly and including 2.5 Sqmm earth wire, PVC insulated & unsheathed all as directed. Note:- Two run of main wire and one run of earth wire including PVC conduit shall be measured as one length.
69Supply and fix in repair vertical type storage water heater with stainless steel inner tank including heating element, all accessories, fixing arrangement etc complete of capacity 25 ltrs all as Specified.