Military Engineer Services-MES has published Provision Of Room For Artificial Reality (Ar)/ Virtual Reality (Vr) At Af Station Bhisiana Under Ge (Af) Bhisiana. Submission Date for this Tender is 27-05-2024. Building Work Tenders in bhisiana Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

43268564
Corrigendum : Provision Of Room For Artificial Reality (Ar)/ Virtual Reality (Vr) At Af Station Bhisiana Under Ge (Af) Bhisiana
Open Tender
Indian
Punjab
bhisiana
27-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Provision Of Room For Artificial Reality ( Ar ) / Virtual Reality ( Vr ) At Af Station Bhisiana Under Ge ( Af ) Bhisiana

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 20-May-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 27-05-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 49200.0 /-
Tender Value
INR 24.60 Lakhs /-

Attachment

FileName File Description File Size
ee90c502-95b5-4ebd-b357-d33b4b1b2fc2.html Tender Notice 0 KB
BOQ_729508.xls Tender Document 0 KB
Drawing.pdf Tender Document 0 KB
TenderDocuments08.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: PROVISION OF ROOM FOR ARTIFICAL REALITY (AR)/ VIRTUAL REALITY (VR) AT AF STATION BHISIANA UNDER GE (AF) BHISIANA
Sl. No. Item Description
1Surface excavation n. exc. 30cm deepand averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.
2Excavation in trenches not exc 1.5mtrwide andnot exc 1.5mtr in depth for foundation in soft/loose soil etc or for shaft, wells, cesspits, manhole, pier holes etc not exc 10 sqm on plan and not exc 1.5mtr in depth and getting out complete all as specified and as directed.
3Returning filling in including spreading leveling watering and well ramming in layers not exc 25 cm thick each complete all as specified and as directed.
4Removal of surplus soil to a distance not exc 50 mtrs & depositing where directed at a level not exc 1.5 mtrs above the starting point complete all as specified and as directed.
5Material and labour for PCC 1:4:8 type D-2, (using 40 mm graded aggregate),as in foundations, filling and mass concrete, sub base, floor etc complete all as specified and directed by Engr-in-Charge.
6Material and labour for reinforced cement concrete M-25, (Design Mix) using 20 mm graded stone aggregate as in foundations including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engr-in-Charge.
7Material and labour for reinforced cement concrete M-25, (Design Mix) using 20 mm graded stone agg as in Columns, pillars, piers, posts and struts complete all as specified and directed by Engr-in-Charge.
8Material and labour for reinforced cement concrete M-25, (Design Mix) using 20 mm graded stone agg as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by Engr-in-Charge.
9Material and labour for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams for rough finished surface of concrete surface; and similar work; vertical or to batter complete all as specified and directed by Engr-in-Charge.
10Material and labour for form work to sides of pillars/ posts etc. struts, columns, piers etc square/rectangular etc for rough finished surfaces of concrete complete all as specified and directed by Engr-in-Charge.
11Material and labour for form work to sides and soffits of floor or roof beams, beam haunchings, lintel beam, beams, girders, bressummers, lintel, cantilevers, shelves including supports, over hangs etc. also splays between floors and beams etc for flat, rough finished surfaces of concrete complete all as specified and directed by Engr-in-Charge.
12Material and labour for TMT steel bars 10 mm dia and over cut to length bent to shape required including cranking, bending spirally,for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or squaring with clips complete all as specified and directed by Engr-in-Charge.
13Material and labour for TMT bars 5mm dia and over upto and including 10mmdia cut to length bend to shape required, including cranking bending spirally for hooping for stirrups , spacers and binders not less than 0.9 mm dia or securing with clip complete all as specified and directed by Engr-in-Charge.
14Supply and fixing for Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe 410-W (Gde E-250, quality - A) complete all as specified and directed by Engr-in-Charge.
15Supply and fixing of Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment in Fe 410-W (Gde E-250) quality A complete all as specified and directed by Engr-in-Charge.
16Supply and fixing of mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with including washers and one hexagonal or square nut exc 22.5 cm and not exc 100 cm long of 20mm dia complete all as specified and directed by Engr-in-Charge.
17Material and labour for preparation of new steel surfaces of any description not otherwise described over 10cm width or grith and applying two coats of synthetic enamel paint over a coat of red oxide primer exposed to view surfaces complete all as specified and as directed.
18Supply and fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge.
19Supply and fixing Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge.
20Material and labour for rendering 15 mm thick cement plaster in CM (1:4) mixed with integral liquid water proofing compound on fair faces of brick or concrete surfaces and finishing the surface even and smooth (without using extra cement) etc. complete all as specified and directed. Note : WPC measured and paid separately under respective items.
21Material and labour for rendering 10mm thick cement plaster in CM (1:6) on fair faces of brick or concrete surfaces and finishing the surface even and smooth (without using extra cement) etc. complete all as specified and directed.
22Supply only integral waterproofing compound complete all as specified and directed.
23Material and labour for preparation of new plastered surfaces and applying two coats of oil emulsion distemper white/ tinted with 3mm thick wall care putty finished surface complete all as specified anddirected .
24Material and labour for preparation of new plastered surfaces and applying two coats of cement base paint over a coat of cement base primer complete all as specified anddirected .
25Material and labour for machine cut kota stone slab as in flooring of size 580 x 580 mm each & 18-20 mm thick, set and jointed in cement slurry including border of 100mm wide baroda green/white mable as per pattern approved over & including screedof 20-22 mm thick in cement mortar (1:4) and pointed in cement mixed with pigment to match the shade of slab including rubbing, cutting and mirror type granite polishing complete all as specified and directed. Note : 1. All the edges of slabs shall be grinded/cutted at the right angle before laying, so that paper thin, smooth jointing to be obtained. 2. The colour of the slabs shall be uniform.
26Material and labour for machine cut kota stone slab as in skirting of 18-20 mm thick, set and jointed in cement slurry over & including screedof 10 mm thick rendering in cement mortar (1:4) and pointed in cement mixed with pigment to match the shade of slab including rubbing, cutting and mirror type polishing complete all as specified and directed .
27Material and labour for 25mm thick PCC 1:2:4, type B-0 (using 12.5mm graded stone aggregate), as in floor, sub base finished fair & even without using extra cement complete all as specified and directed .
28Material and labour for Machine pressed rubber moulded ISI marked precast cement concrete interlocking paver block any shape and size and of colourcoloured tiles confirming to IS-15658-2006 of 60mm thickness M-35 Gradewith grey cement and pigment completeall as specified.
29Material and labour for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
30Supply and fixing of anodised powder coating of colour approved ofaluminium door shutter aluminium section weighting 0.55kg/m incl necessary joinin cleats, glazing clips, rubber neoprene packing, handles 2 nos in each door, hinges,incl locking arrangement, anodising aluminium snap beading screws etc. complete all as specified and directed.
31Supply and fixing of anodisedpowder coated of any colour aluminium window and ventilators shutters, side hung type without sash bars, aluminium section weighting 0.55kg/m incl necessary joinin cleats, glazing clips, rubber neoprene packing, snap beading, screws, aluminium fittings, handles 2 nos in each windows, hinges, screws,incl aluminium grill etc complete all as specified and directed.
32Material and labour for powder coatedof any colour aluminium minimum thickness of powder coating 50 micron work for doors, windows, ventilators and partitions with extruded built up standard tubular section/Z section and other section of approved make including necessary filling up the gap at junction and side with required EPDM RUBBER/ Neoprene gasket etc. complete all as specified and directed.
33Supply and fixing of 200 mm long Aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed.
34Supply and fixing offloor door stopper of aluminium body overall length of cover plate 150 mm fixed complete all as specified and directed.
35Supply and fixing of door closer hydraulically regulated, cast iron body designation No 2 universal type, suitable for door shutter of 701 to 850mm in width and of weight between 36 to 60 kg complete all as specified and directed.
36Supply and fixing of double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts of mild steel heavy duty and fixed complete all as specified and directed.
37Supply and fixing of Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples fixed complete all as specified.
38Material and labour for brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directed.
39Material and labour for PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregates) as in roof kerbs, gusset plate fixingbenches and water troughs etc. including necessary moulding complete all as specified and directed.
40Supply and fixing of gypsum board/tiles8-10mm thick in ceiling fixed with screws as per manufacturer instructions plain/ colour fixed with steel snap grid(power coated bottom side) with T and L (25mm*30mm*1mm thick) section of size 600mm*600mm placed in ceiling L section fixed with wall with PVC rawal plugs and steel screws @600mm centre to centre and suspended/provided 5mm dia galvanised bar @1 sqm hanging arrangement and levels including adjustable clips, complete all as specified in clause 10.38 of schedule part-1 complete all as specified. Note : If any minor electrical and fixtures distributed their in will be match and fixed as existing) complete all as specified and directed.
41Supply and fixing of 4.00 mm thick sheet glass, ordinary quality and glazing with oil putty in squaren exc 0.5 Sqm fixed in windowframe complete all as specified and directed.
42Material and labour for cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in plinth protection, 50 mm thick, surfaces finished even and smooth without using extra cement as in plinth protection including provision of construction joints, filled with polyurethane elastic adhesive/sealant (white/grey colour-sikaflex) of approx density 1.30kg/litreand form work complete all as speciified and directed by Engr-in-Charge.
43Material and labour for point wiring complete with ISI marked 1.5 SqmmPVC insulated unsheathed multistrand single core cable with copper conductor (FRLS)1100volts grade drawn through and including rigid PVC conduit medium grade minimum 20 mm dia ISI marked as required at site including conduit accessories fixed concealed in wall/ ceiling/ roof etc by means of saddles and clamp etc including PVC gang boxes as reqired at site for concealed/surface conduit wiring and modular plates & covers as required at site for housing switches, sockets, regulators etc. including providing of 4 sqmm PVC insulated multistranded, unsheathed FRLS copper conductor as earth continuity conductor and connecting to common earth dolly complete all as specified and directed for and connecting up complete for the following :- (a) One light/ fan point controlled by one, one way switch
44All as per Srl Item No. 43 here-in-before but for one ceiling fan/ exhaust fan point controlled by one way switch 6 Amps complete all as specified and directed.
45All as per Srl Item No. 43 here-in-before but for switch socket outlet 2/3 pins 6 Amps on independent board complete all as specified and directed.
46All as per Srl Item No. 43 here-in-before but for switch socket outlet 2/3 pins 6 Amps on same board complete all as specified and directed.
47Material and labour for point wiring complete with ISI marked 4 SqmmPVC insulated unsheathed multistrand single core cable with copper conductor (FRLS)1100volts grade drawn through and including rigid PVC conduit medium grade minimum 20 mm dia ISI marked as required at site including conduit accessories fixed concealed in wall/ ceiling/ roof etc by means of saddles and clamp etc including PVC gang boxes as reqired at site for housing switches, sockets, regulators etc. including providing of 4 sqmm PVC insulated multistranded, unsheathed FRLS copper conductor as earth continuity conductor and connecting to common earth dolly for 15 Amp switch socket combination complete all as specified and directed.
48Supply and fixing of modular socket 6A, 5 Pin combined two module type complete all as specified and as directed by Engineer-in-Charge.
49Supply and fixing of modular socket 6A/16A, 6 Pin combined two module type complete all as specified and as directed by Engineer-in-Charge.
50Supply and fixing ofmodular 1 way 6 Amp switch 1 module complete all as specified and as directed by Engineer-in-Charge.
51Supply and fixing of modular 1 way 15 Amp switch 1 module complete all as specified and as directed by Engineer-in-Charge.
52Supply and fixing of LED luminaire 1ftx4ft, 33/36/40 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare light with LED efficacy of not less than 100 Im/watt electronic driver, suitable for roof ceiling including connecting up with driver three core copper conductor 1.5 sqmm size complete all as specified and as directed by Engineer-in-Charge.
53Supply and fixing of LED luminaire 600mmx600mm, 35-36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare light with LED efficacy of 120 Im/watt electronic driver, suitable for roof ceiling including connecting up with driver three core copper conductor 1.5 sqmm size complete all as specified and as directed by Engineer-in-Charge.
54Material and labour for submain wiring with 2 runs of copper conductor PVC FRLS insulated unsheathed cable 1100 volts grade 4 sqmm draw through PVC conduit medium grade ISI marked 25 mm dia as per IS specification fixed concealed in wall/ ceiling including conduit and conduit accessories and includingprovision of PVC insulated 4 Sqmm multistandard copper conductor as earth continuity conductor connected to the earth dolly complete all as specified including making good to the disturbed surface by plastering and two coat of distamper all as directed at site. Note : Two runs of 4 Sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheted cooper conductor as earth wire conduit and conduit accessories will be measured a one length.
55Material and labour for submain wiring with 2 runs of copper conductor PVC FRLS insulated unsheathed cable 1100 volts grade 6 sqmm draw through PVC conduit medium grade ISI marked 25 mm dia as per IS specification fixed concealed in wall/ ceiling including conduit and conduit accessories and including provision of PVC insulated 6 Sqmm multistandard copper conductor as earth continuity conductor connected to the earth dolly complete all as specified including making good to the disturbed surface by plastering and two coat of distamper all as directed at site. Note : Two runs of 6 Sqmm cable alongwith one run of 6 Sqmm PVC insulated unsheted cooper conductor as earth wire conduit and conduit accessories will be measured a one length.
56Supply and fixing of MCB DB 12 way SPN (double door) sheet metal enclosure factory made suitable for MCB DBs 240 volts with 200 Amp rated busbar, neutral & earthing link bar, flush/surface mountingcomplete all as specified and as directed by Engineer-in-Charge.
57Supply and fixing of MCB TPN DB 04 way (double door) sheet metal enclosure factorymade suitable for MCB TPN incomer and MCBs as outgoing with 200 Amp rated busbar, neutral & earthing link bar, flush/ surface mounting complete all as specified and as directed by Engineer-in-Charge.
58Supply and fixing of MCB SP 6-32 Amps working on 240 volts, 50 Hz AC, 10 KA "C" curve complete all as specified and as directed by Engineer-in-Charge.
59Supply and fixing of MCB SPN 32-40 Amps working on 240 volts, 50 Hz AC, 10 KA "C" curve complete all as specified and as directed by Engineer-in-Charge.
60Supply and fixing of MCB 4 pole operating on 415 Volts, AC supply of capacity 63-100 Amps, 10KA "C" curve complete all as specified and as directed by Engineer-in-Charge.
61Supply and fixing of MCCB 100 Amps, 3/4 pole, 16KA, 415 Volts, 50 Hz, ICU=100% ICS thermal magnetic fixed and short circuit rating including necessary fixing arrangement for fixing of MCCB to thepanel, connecting cable connections complete all as specified and as directed by Engineer-in-Charge.
62Supply and fixing of metallic AC earth plug and socket with sheeet metal enclosure with MCB SP 20A to 32A complete all as specified and as directed by Engineer-in-Charge.
63Material and labour for boring hole under road pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
64Supply and fixing of 15mm bore GI tubing light grade as in protection of GI earth wire complete all as specified and as directed by Engineer-in-Charge.
65Supply, laying, jointing and testing of XLPE insulated screened armoured heavy duty eclctric cable with aluminium conductor 1100 volts grade of size 16 Sq mm 4 Core with alumininum thimble of same size complete all as specified and directed by Engr-in-Charge.
66Material and labour for earthing complete with galvanised steel earth plate electrode 60x60cmx 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia of minimum 15m length by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test pointall as specified or indicated including provision of earth lead protection pipe, PCC earth pit with cover, excavation and earth work, testing on completion with electrical connection to earth test point complete all as specified and directed by Engineer-in-charge.