Tender For Repair To Destressed Members, Roof Treatment Including Periodical To Otm Bldgs In Tech Area At Af Stn Gwalior, gwalior-Madhya Pradesh

Military Engineer Services-MES has published Tender For Repair To Destressed Members, Roof Treatment Including Periodical To Otm Bldgs In Tech Area At Af Stn Gwalior. Submission Date for this Tender is 22-05-2024. Building Work Tenders in gwalior Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43268558
Tender For Repair To Destressed Members, Roof Treatment Including Periodical To Otm Bldgs In Tech Area At Af Stn Gwalior
Open Tender
Indian
Madhya Pradesh
gwalior
22-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Repair To Destressed Members, Roof Treatment Including Periodical To Otm Bldgs In Tech Area At Af Stn Gwalior

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

Attachment

FileName File Description File Size
3e13e155-d5a2-43d1-9810-70f30f6a9cd6.html Tender Notice 0 KB
BOQ_729517.xls Tender Document 0 KB
TENDERDOC1529.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work : REPAIR TO DESTRESSED MEMBERS, ROOF TREATMENT INCLUDING PERIODICAL TO OTM BLDGS IN TECH AREA AT AF STN GWALIOR
Sl. No. Item Description
1Demolition of brick work or stone masonry of any description and in any position built in cement mortar including all quoins, arches pillar etc including disposal of rubbish complete all as specified and directed.
2M&L brick work with sub class "B" bricks straight or curved on plan exc 6 M mean radius built in CM (1:6) complete all as specified and directed.
3All as per item No 2 here-in-before but, except brickusing old retrieved bricks obtained from demolition in serviceable conditions complete all as specified and directed.
4M&L for 15mm thick rendering fare face of brickwork or concrete surfacesin CM 1:4 finished even and smooth (without using extra cement)etc complete all as specified and directed.
5M&L for 15mm thick rendering other than fare face of brickwork or concrete surfacesin CM 1:6 finished even and smooth (without using extra cement)etc complete all as specified and directed.
6Demolition ofcement concrete (unreinforced) of any descriptionand in any position not otherwise specifically provided for complete all as specified and directed.
7M & L for PCC (1:2:4) type B-0, using 12.5mm graded stone aggregate as in cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones, bed plates, kerbs including necessary form work complete all as specified and directed by Engr-in-Charge.
8Demolition of cement concrete ( reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
9M&L for RCC (1:2:4) type B-1 (using 20mm graded aggregate) as in shelves, chajja , etcincluding necessary form workcomplete all as specified and directed. (Note : Reinforcementshall be measured and paid separately)
10M&L for RCC (1:2:4) type B-1(using 20mm graded aggregate) as in Fins, fascias, louvres, parapets, and railings exc. 60cm in height, newels, balustrade, and the like for etcincluding necessary form workcomplete all as specified and directed. (Note : Reinforcementshall be measured and paid separately)
11M&L for RCC (1:2:4) type B-1 (using 20mm graded aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like including necessary form workcomplete all as specified and directed. (Note : Reinforcementshall be measured and paid separately)
12M&L for RCC (1:2:4) type B-1 (using 20mm graded aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m spanincluding necessary form workcomplete all as specified and directed. (Note : Reinforcementshall be measured and paid separately)
13M&L for RCC (1:2:4) type B-1 (using 20mm graded aggregate) as in Columns, pillars, piers, postsincluding necessary form workcomplete all as specified and directed. (Note : Reinforcementshall be measured and paid separately)
14S&F mild steel TMT bars of 10 mm diaandover cut to length, bent to shape as requiredincluding cranking, bending, spirally for hooping for column hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia for securing with clips complete all as specified and directed.
15ALL as per item No 14 here-in -beforebut 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders.
16M&Lfor removing/chipping 40 to 60 mm depth of existing loose concrete carefully by manual or low impact frequency hammer without damaging the existing concrete including cleaning the surface by compressed air jet complete including removing loose concrete around the reinforcement. The debris will be disposed up to lead of 500m. The entire surface will be checked by light hammering (using 1 kg hammer) for detection of loose concrete. All loose/hollow sound concrete around corroded reinforcing bars has to beremoved to prepare well defined patch all as specified and as decided.
17M&Lfor drilling hole in RCC/Bricks structure using drilling machine up to a depth of 150 mm depth or half the thickness of member (whichever is less) and removing dust, etc by vaccum cleaner and blowers, providing and fixing of 12mm dia Polytetrafluoroethylene (Teflon) nozzes @ 750 mm c/c in both directionand inject cement slurry by using OPC 43 grade cement mixed water in the ration of 1:2 (01 part cement and 02 part water ) and removal of excess cement slurry and nozzles carefully after grouting complete all as directed.
18M&Lfor cleaning of rusted reinforcement of total rust including from behind the reinforcing bars to give it totally rust free finished steel surface, by manual methods and using approved alkaline chemical rust remover (Pidilite/FOSROC/CICO/Thermax as per specification) as per approved paint Brush and removing loose particles after 24 hours of its application with wire brush andthoroughly washing with water and following it to dry and clean with dry cloth before application of protective coating etc complete all as specified and directed.
19M&Lanticorrosive treatment to exposed reinforcing bars in two coats as per specifications using approved Zn rich epoxy phenolic rebar protection product (Pidilite/CICO/Forsroc/ Thermax ) complete all as specified and as directed.
20M&Lfor providing and applying concrete Penetrating Corrosion Inhibitor (CPCI) as per specification in two coats @ 4 Sq mt / ltr/coat of approved brand (CICO/Thermax/ forsroc Specification) on areas demarcated specifically complete all specified and directed.
21M&L for applying a coat of structural grade single/ two component epoxy bonding agent of approved brand (Pidilite/CICO/FOSROC as per Specification) conforming to ASTM C - 881 - 13 Type - II tested as per ASTM - C882 - 13 or granolithic E-resin based solvent free concrete bonding agent of mix density of chemical 1.45 to 1.50 kg/ltr) with a bond strength specified in ASTN C - 881 - 11 of Make Thermax etc. to ensure bond between old and new concrete prior to application of any type of mortar/ concrete complete all specified and directed
22M&L for polymer modified mortar to build the profile of structural members upto 40 to 60 mm depth by using (i) emulsified SBR latex (Thermax/Pidilite/CICO/FOSROC as per manufacturer"s specifications) conforming to ASTM C - 1059 - 13 Type - II in damaged areas (1 cement conforming to OPC 43 grade - 3 part graded cleaned river sand conforming to Zone - II grade of IS : 383 + 20 % latex by weight of cement) with 0.35 water/ cement ratio, in 15-20 mm thick layers by applying bond coat (Payable under BOQ item no. 7 above) between successive/ each layers,. or (ii) rheoplastic non shrink corrosion resistant, high strength compound BS 66 (BS 66 micro concrete mix with cement ratio 1:4 using OPC 43 grade cement) of Make Thermax/ Chemco system etc by confirming to the required compressive strength and expansion characteristics specified in ASTM C 109, ASTM C 348, ASTM D 469, ASTM C 827 - 1987 complete all as specified and as per manufacture instruction. Note - (i) Placing of the materials shall be using suitable arrangements such as pumping device for uniform flow of materials and providing side shuttering if required.(ii) Curing shall be done as per manufacturer instructions and all as directed
23Filling the cracks in isolated placed (other than the locations mentioned above) of columns, beams after opening up in "V:" groove manner covering the area of 300 mm from central line of crack with the depth of 50 mm ,with components of compound specified in Make : Thermax or equivalent in CICO/ FOSROC/ PIDILITE.
24M&L for Providing, cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregates) in roof kerbs or mud stops, rounded or chamfered on edges and padding over roof surfaces etc complete all as specified and as directed.
25M&L for Cement concrete tiles 20cm x 20cmx 20mm thick, machine pressed; set jointed and pointed in neat cement slurry in roofs, and pointed in neat cement slurry with grey cement and no pigment over 15mm thick screed bed in CM 1:4 including dismantling of existing tiles with screed without disturbing the roof treatment/ bitumenous feltcomplete all as specified and directed.
26Supply only liquid water proofing compound complete all as specified and directed.
27M & L for 10 mm thick screed bed in cement mortar 1:4 mixedwith usingliquid water proofing compoundas per manufacturers instructions (Note:Water proofing compound shall be measured and paid separately under respective item of "BoQ")over roof top surface finished even and smooth using extra cement and application of water proofing treatment using APP modified roof membrane over existing inaccessible RCC roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specification etc complete all as specified and directed :- (a) Cleaning existing surface properly. (b) Applying bitumen primer @ 0.30 litre / Sqm manufactured by the same agency as that of APP membrane with a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface. (c) Applyinghot blown grade bitumen 85/25 @ 1.2 Kg/Sq M over primer. (d) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.00 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gsm/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap by authorized applicators. (e) Applying a coat of Aluminium Paint over APP Membrane.
28S&F in repairs 150mm dia PVC (SWR) pipes single socketed in any length at any height with rubber ring joints fixed to walls/ hanger cladding with necessary brackets including tee and bends.
29M&L for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including Dismantling of existing Plain or corrugated steel /AC Sheetcomplete all as specified and directed.
30M&L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, Ridge, valley/ gutter fixed with self tapping screwsincluding Dismantling of existing Plain or corrugated steel /AC Sheet complete all as specified and directed.
31M&L for 5mm thick rendering on concrete surfaces as in celinig in CM 1:3finished even and smooth without using extra cement incl taking down cement plaster on concrete surface incl preparation of newly plastered surface andapplying three coats of white wash complete all as specifiedand directed.
32M&L for 15mm thick rendering fare face of brick/stone masonry wallsin CM 1:4 finished even and smooth (without using exrtra cement) including taking down cement plaster on brick surface or stone including raking out joints hacking for key, scrubbing down with water etc complete all as specified and directed.
33M&L for Preparation of old decorated surfaces of wall including cornices, by brooming down or steel wire brushing to remove dust, dirt and loose scales of lime wash and other foreign material, scrapping down, smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots etc including filling the cracks and depressions with putty and applying one coat of white wash by the use of rollers complete all as specifiedand directed.
34Ditto as per item 33 above but one coat of white wash on ceiling surface complete all as specified and directed.
35M&L for Preparing old decorated plastered or unplastered surfaces of external walls and applying one coats exterior weather proof Paintby the use of rollers including filling cracks/depressions with putty to make the adjacent surface even and smooth complete all as specified and directed.
36M&L for Preparing old painted surfaces of wood and wood based materials of any description over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
37M&L for Preparing old painted steel & iron surfaces of any description over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
38M&L for Preparing old painted steel & iron surfaces of any description n.exc 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
39M&L for preparation of surfaces of wood and wood based materials of any description, width or girth including cleaning and a coat of wood filler on old works and applying french polish in one or more coats to the required texture and glossy finish complete all as specified and directed
40M&L for prepration of old decorated Brick tile /Concrete tiles (Chequered /interlocking tiles) cleaning by any means, andapplying one coat of floor tile paint any colour with spray gun/compressor complete all as specified and directed as approved by Engr-in-Charge. Make: INDOGO Floor Paints or Apex Floor Guard of Asian Paints
41M&L for preparation of old painted surface and applying one coats of aluminium painton steel surface of any description over 10cm in width or girth completed all as specified and directed.
42M&L for Complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers or any other means, andfilling the cracks and depressions with putty/ chalk whitening to make the surface even and smooth matching to the adjacent wall surfaces and applying two coats exterior weather proof Paint by the use of rollers over a coat of primer white or tinted as approved complete all as specified and directed.
43M&L for Complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers or any other means, andfilling the cracks and depressions with putty/ chalk whitening to make the surface even and smooth matching to the adjacent wall surfaces applying two coat of external emulsion paint/weather coat,in camouflaging pattern on CCD scheme (Pattern as approved by GE) on surfaces of any type of building, wall, any surfaces, any height, over a coat of primer complete all as specified and directed.Note- Rate quoted by contractor incl scaffolding and T&P upto 15m height of the building. No extra payment admissible on this account.
44M&L for applying one coat of external emulsion paint/weather coat,in camouflaging pattern on CCD scheme (Pattern as approved by GE) on surfaces of any type of building, wall, any surfaces, any height, incl preparation of old decorated surfaces complete all as specified and directed.Note- Rate quoted by contractor incl scaffolding and T&P upto 15m height of the building. No extra payment admissible on this account.
45M&L for Preparation of newly Plasteredsurfaces and applying two coats of white wash complete all as specifiedand directed.
46M&L for Preparation of newly plastered surface andapplying two coat of weather coat exterior emultion (Make : ACE of Asian Paints or equivalent in Berger Paints etc)white or tintedby the use of rollers over a coat ofprimer as approved complete all as specifiedand directed.
47M&L for Preparation of newly plastered surface andapplying two coat of distemper oil emulsion white or tintedby the use of rollers over a coat of calk whiening primer (preparatory to distempering)as approved complete all as specifiedand directed.
48Removal of defective concrete, cleaning the surface thoroughly,applying the shotcrete mixture mechanically with compressed air under pressure, comprising of cement, sand, coarse aggregates, water and quick setting compound in the proportion as per manufacturer"s instructions or as directed, sand and coarse aggregates conforming to IS: 383 and table1 of IS:9012 respectively, water cement ratio ranging from 0.35 to 0.50, density of gunite not less than 2000 kg/cum, strength not less than 25 MPa(40 mm average thickness)
49Guniting concrete surface with cement mortar (25 mm nominal thick) applied with compressor after cleaning surface and spraying with epoxy complete all as specified and directed.
50Taking down carefully aluminum /copper point wiring (light, fan, switch & power) complete including fittings such as switches, ceiling rose, pendent, byunscrewing from board ,out let box, fitting and fixture such as bulk head fitting, sketch fittings and making good the disturbed rurfaces of walls floors etc complete all as specified and directed.
51M&L for point wiring with stranded copper conductor 1.5. Sqmm 1100 Volts grade FRLS PVC insulated and unsheathed including ISI marked PVC casing cappingof required sizes as indicated including all accessories, copper conductor cable 1.5 Sqmm insulated and unsheathed PVC cables as earth wire, trminal boxes closed recossed type.PVC Plastic board all asrequired as specified and directed for the following :- (a) One light/ Fan point controlled by one way switch.
52(b )One 5 Amps switch socket combination on independent board.
53(c) One 5 Amps socket on same board with other switches.
54All as per item No-51 here in above but 2.5 Sqmm stranded copper conductor and independent board for 15 Amps switch/ socketpoint as complete all as specified and directed.
55S&F switch piano flush type single pole one way 5 Amps 230 VISI marked complete all as specified and directed.
56S&Fswitch socket out let 3 pin 5 Amps flush type 230 Volts multipurpose, ISI marked complete all as specified and directed.
57S&F switch socket out5 Amps and 15 Amps multipurpose( 3 Pin 15 Amps and one pin 5 Amps controlled by one switch.)ISI marked complete all as specified and directed.
58S&F fan regulator Electronic Step type (min 5 steps) 2module, 100W ISI marked by removing old u/s resistance type fan regulator including necessary connection in existing laminated switch board by making necessary holes etc., complete all as specified and directed by Engineer-in-Charge.
59S&F lamp holder insulated body with back plate for battern fittings complete all as specified and directed by Engr-in-charge.
60M&L for sub main wiring in replacement using two single core PVC insulated,unsheathed stranded copper conductor cable of size 4 Sqmm FRLS of voltage rating 1100 Volts drawn in and including surface in PVC casing caping with standard accessories, along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified and directed. NOTE:Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
61M&L for sub main wiring in replacement using two single core PVC insulated,unsheathed stranded copper conductor cable of size 6 Sqmm FRLS of voltage rating 1100 Volts drawn in and including surface in PVC casing caping with standard accessories, along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor complete all as specified and directed. NOTE:Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
62M&L for sub main wiring in replacement using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4 Sqmm, FRLS of voltage rating upto and including 1100 Volts drawn in existing conduitalong-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified and directed. Note:-Two run of single core PVC cable with one run of earth conductorshall be measured as one unit.
63M&L for sub main wiring in replacement using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm FRLS of voltage rating upto and including 1100 Volts drawn in existing conduit along-with one run of PVC (Green colour) insulated , unsheathed, stranded copper conductorof size 6 Sqmm as earth continuity conductor complete all as specified and directed. Note:-Two run of single core PVC cable with one run ofearth conductorshall be measured as one unit
64Supply, fixing, connecting & testing in repairs of sheet metal enclosures single pole and neutralwith a two pinearth plug and socket complete with one single pole 20 amp MCBcomplete all as specifiedanddirected.
65Supply, fixing, connecting & testing in repairs of sheet metal enclosures (IP-54 Protection) triple pole and earth with three pinearth plug and socket complete with one TPN 32 Amp MCBcomplete all as specifiedanddirected.
66Supply, fixing, connecting & testing in repairs of sheet metal enclosures double door (IP-42 Protection), triple pole and neutral, 4 way DBs for using MCBs / MCB isolators with having aluminium bus bars suitable for 200 Amps ratingcomplete all as specifiedanddirected.
67All as per item No.64 here-in-before but distribution board single pole and neutral, 12 way complete all as specifiedanddirected.
68All as per item No.64 here-in-before but distribution board single pole and neutral, 8 way complete all as specifiedanddirected.
69All as per item No.64 here-in-before but distribution board single pole and neutral, 4 waycomplete all as specifiedanddirected.
70Supply& Fixing in replacement of LED Batten fittings 1x20 Wattcomplete with round blocketc,incl PVC gutties and flexible wire and connecting to ceiling rose complete all as specified and directed by Engineer-in-Charge.
71S & F in replacement of LED light fitting 1x9W/1X10Wbulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge.
72Supplying and fixingin replacement of decorative surface mounting 36 watt LED full out put luminaries which provides soft light glare free symmetrical illumination suitable for Armstrong/Gridceiling, white powder coated sheet steel housing with paralite P5 square parabolic louver block in metallic perforated frame for low glare, aluminium reflector and accessories ,connecting the same to electric source with and including copper conductor 23/0.0076 flexible twisted twin core cable ,including all accessories and fixing arrangements for fixing the2x2 LED light fitting to false ceiling complete all as specified and directed by Engineer-in-Charge.
73Supply and fixing in replacement of post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engr-in-charge.
74S&F in replacement of 10 Watt LED bollard light one meter long with Opel acrylic diffuser and IP-65 protection including necessary PCC base work complete all as specified and directed by Engineer-in-Charge.
75Supply and fixing in replacement of LED building security/street light light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engineer-in-Charge.
76Supply and fixing in replacement of LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engr-in-charge.
77All as per item No. 74, but LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engr-in-charge.
78All as per item No. 74, but LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engr-in-charge.
Disclaimer :