Tender For Improvement Of Certain Married Accommodation At Begam Bazaar And Other Sanctioned Works Under Ge (Af) Bamrauli, bamrauli-Uttar Pradesh

Military Engineer Services-MES has published Tender For Improvement Of Certain Married Accommodation At Begam Bazaar And Other Sanctioned Works Under Ge (Af) Bamrauli. Submission Date for this Tender is 18-05-2024. Building Work Tenders in bamrauli Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43263973
Tender For Improvement Of Certain Married Accommodation At Begam Bazaar And Other Sanctioned Works Under Ge (Af) Bamrauli
Open Tender
Indian
Uttar Pradesh
bamrauli
18-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Improvement Of Certain Married Accommodation At Begam Bazaar And Other Sanctioned Works Under Ge ( Af ) Bamrauli

Key Value

Document Fees
INR 500 /-
EMD
INR 98700.0 /-
Tender Value
INR 49.34 Lakhs /-

Attachment

FileName File Description File Size
d2b485b1-6196-4de6-b894-523f9fd65a13.html Tender Notice 0 KB
BOQ_729298.xls Tender Document 0 KB
Tender.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: IMPROVEMENT OF CERTAIN MARRIED ACCOMMODATION AT BEGUM BAZAAR AND OTHER SANCTIONED WORKS UNDER GE (AF) BAMRAULI
Sl. No. Item Description
1Taking down chowkats with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames) complete all as specified and directed.
2Taking down chowkats or frames with shutters (without taking of shutters from the frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and directed.
3S&F for Pressed steel frames of size 125mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed.
4S&F for Pressed steel frames of size 105mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed.
5M & L for Solid PVCFrame for door,kitchen cabinet,cupboardof size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawingcomplete all as specified and directed.
6S&F Factory made solid panel PVC door shutter 30 mm thick (style)both side prelam pvc sheet of decortive choice consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat mouldedPVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site asperspecification &drawing.complete all as specified and directed.
7S&F Second class hardwood glazed and skeleton door shutters 35mm thick, open rebated and prepared to receive glass, gauze, etc (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc complete all as specified and directed.
8S&F Second class hardwood Flush shutters 30mm thick, solid core construction, with block board core & plywood face panels, commercial type on both sides complete all as specified and directed.
9Dismantling of asbestos cement (corrugated, semicorrugated , etc) sheet in roof covering all as specified and directed.
10S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering or fixed to wall with self tapping screws complete all as specified and directed.
11S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded all as specified and directed by engineer in charge.
12S&F Steel windows without glazing bar with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded all as specified and directed by engineer in charge.
13S&F Steel windows or ventilators, fixed type, with glazing bars all as specified and directed by engineer in charge.
14S&FStainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staplesetc complete all as specified and directed.
15S & F4mm th Sheet glass, ordinary qualityin square in notexc 0.5 sq.m in each pane complete all as specified and directed.
16S & F 4mm thick Figured glass, pin head typein squares in n exc 0.5 sq.m in each pane complete all as specified and directed.
17Excavation in trenches for n.exc 1.50m wide not exceeding 10 Sqm on plan and n.exc 1.5m in depth in soft/ loose soil and getting out all as sfd and directed.
18M&L 100mm thick Cement concrete 1:5:10 type E-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete all as specified.
19Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. all as specified and directed.
20Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m. all as specified and directed.
21M&L for M25 Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, all as specified and directed.
22M&L RCC M-25 type B1 (1:2:4) Columns, pillars, piers, posts and struts all as specified and directed.
23M&L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter all as specified and directed.
24M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchionsall as specified and directed.
25S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, includingcranking, bending spirally for hooping for columns, hooking ends and bindingwith and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as sfd and directed.
26S&F MS 1.25 mm thick MS plain black sheet in steel gates and similar work, cut to size, holes punched, including round headed screws and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded as required.complete all as specified and directed.
27M&L for Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanksand similar work conforming to Fe 410-0 or Fe 310-0. complete all as spesified and directed .
28M&L for preparing new or previously untreated surfaces of wood or wood based materials of any descriptionexc 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
29M&L for preparing new or previously untreated steel surfaces of any description not otherwise describedover 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
30M&L for PCC 1:3:6 type C-1 using 12.5 mm granted stone aggregate ashold fast/filling in pressed steel frame complete all as specified and directed
31S&F 100mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin,anodised and fixed, typeB-21 complete all as spesified and directed .
32S&F 300 mm long Aluminium alloy with dia 16mm, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy.complete all as spesified and directed .
33S & F 125 mm long Extruded Aluminium alloy handles, fabricated type, anodised.complete all as spesified and directed .
34S & F 200 mm longAluminium anodised barrel tower bolts of extruded section.complete all as spesified and directed .
35S&F for 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as spesified and directed .
36S&F for 150mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as spesified and directed .
37S&F in repair 18mm thick celuka PVC sheet minimum 600 Kg/Cum density grade 1 quality one side pre-laminated and other side plain white colour to make kitchen cabinet/drawer shutters fixed with screws, solvent cement/adhesive and parliyament hinge as requred as per manufacturer instructions complete as per specifications and as directed by the Engineer-in-Charge. Note:-(i) Cup board accessories ie fittings,handles,hinges, will be measured and paid under this schedule. (ii) Quoted rates deem to be include fixing of cabinet on wall with appropriate rawl plug/ dash through fastener (hammer type). (iii) Fabrication and installation of cabinet to be carried out by authorised vendor of manufacturer only.
38S&F in repair 18mm thick celuka PVC sheet minimum 600 Kg/Cum density grade 1 quality of both side plain white colour rigidlam glossy finish fixed with screws, solvent cement/adhesive as per manufacturer instructions to make kitchen cabinet sides top and bottom and shelves inside the cabinet completeas per specifications and as directed by the Engineer-in-Charge. Note:- (i) Cup board accessories ie fittings,handles,hinges, will be measured and paid under this schedule. (ii) Quoted rates deem to be include fixing of cabinet on wall with appropriate rawl plug/ dash through fastener (hammer type). (iii) Fabrication and installation of cabinet to be carried out by authorised vendor of manufacturer only.
39S&F in repair fancy type decorated Stainless Steel curtain hanging rods 20 mm dia,and fixed to stainless steel bracket for hanging curtain complete all as specified and directed.
40S&F Stainless Steelbrackets having screw for tighting of curtain rod of 20mm dia for fixing of curtain rod, complete all as specified and directed.
41S & F Stainless Steelbright color decorative corner/end cap for Curtain rod complete all as secified and directed.
42S&F stainless steel peg set of six with base plate and fixed to wall/door with rawal pugs/ s/s screw all as specified and directed.
43S&F shelf of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight 300gms) complete all as specified and directed .
44S&F in repair CP vitreous china soap dish fancy type complete all as specifed and directed.
45S&F 600 mmx450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC buildg board or commercial plywood and fixed to wooden plugs with CPbrass screws and cup washers complete all as specified and directed.
46S&F in repairBrass chromium plated, tubular towel rails 20 mm dia, D- type, 60 cm long between flanges, completed all as specified and directed.
47S&F in repair brass chromium plated shower roses with swivel joints, 125 mm sizein square with CP long shank arm including fixing to steel pipe or union, complete all as specified and as directed.
48S&F in repair sink with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste; including pvcwaste pipe, CP waste coupling,bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified anddirected.
49S&F 1mm thick stainless steel kitchen plate rack of size 750x 900mm best quality assembled with brass washer and nut and bolts including hooks (spoon/cup holders) complete all as specified and as approved by GE.
50S&F Vitreous china wash down water closet pan (pedestal pattern) white (excluding flushing cistern and flush pipe) and including fixing of the following components viz. pedestal pan with "P" or "S" trap, seat and cover for pedestal pan, flushing cistern, brackets, chain and pull or lever handle, flushing pipe including jointing to socket of flushing rim and connecting pipe to union of flushing cistern, inlet and overflow pipe, anti-syphonage pipe or stopper fixed as in repairs complete all as specified and as directed. Note:- Flushing cistern and flush pipe as required shall be measured and paid for under supply only separately.
51S&F in repairs WC squatting pan “Orissa Pattern” of size 580 x 440mm white with integral foot rest (excluding flushing cistern & flush pipe) including connection to trap and to flush pipes etc and lime concrete bedding complete all as specified in SSR and including S&F trap set complete all as specified and directed.
52S&F in repairs PVC flushing cistern 10 ltr capacity valve less syphonic action type low level with and including dual flushball valve float & handle, waste pipe & brackets complete set complete all as specified and directed.
53S & F in repairVitreous China wash basin, flat back, size 450x300mm white, excluding taps, waste, chain and plug and porcelain stopper but including brackets.
54S&F PTMT grating doom 100mm dia including removing the old grating (minimum weight- 25 gms)
55S&F in repair Waste coupling of PTMT (half or full threaded) . (Minimum weight2mm45gms/40mm 60 gms waste pipe of 40mm dia suitable for WHB, kitchen sink complete all as specifed and directed
56S&F in repair angle cock fancy type CP with long shank cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends of size 15mm bore. complete all as specified and directed. but fancy type, chromium plated with long shank and cup (concealed type)
57S&F in repair angle cock fancy type CP with long shank cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends of size 15mm bore. complete all as specified and directed.
58S&F in repairs bib tap, cast copper alloy with capstan head, CP fancy type with long body shank, screwed down with high pressure screwed for iron pipe & fixed 15mm bore, complete all as specified and directed.
59S & F in repair Pillar taps fancy typecast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered `Hot" or `Cold" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed
60S&F in repairPVC connections 15mm size with PTMT nuts of length 600 mm, complete all as specified and as directed.
61Dismantlingtanks water tank exc 250 but n exc 500 ltr.complete all as specified and directed.
62S&Frotational moulded polythene water storage tank of capacity 500 ltrs (Cylindrical/vertical with closed top), triple layer construction, ISI marked, hoisted & fixed in position including over flow 450mm, waste pipe 600mm long with fitting etc. of 20 mm dia directed complete all as specified and as directed.
63S&F ball/ float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed 20mm bore minimum weight 210 gms complete all as specified and as directed.
64S& F Stop valves/Gate valves 20 mm dia cast copper alloy,screwed down, high pressure with crutch or butterfly handel, screwed both ends for iron pipe or for unions and fixed.complete all as specified and directed.
65Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. capacityexc 250 ltrs n. exc 500 Ltrsand disconnectingexisting tanks settign aside (or lowering if required) for repairs, cleaning etc and hoisting if reuiqred reconnecting and refixing in position. all as specified and directed.
66Taking up or down old steel tubing 15 mm dia complete all as specified and directed.
67Taking up or down old steel tubing 20 mm dia complete all as specified and directed.
68Refixing old15 mm GI tubes medium grade with all fitting and fixed complete to walls, ceilings or laid infloorscomplete all as specified and directed.
69Refixing old20 mm GI tubes medium grade with all fitting and fixed complete to walls, ceilings or laid infloorscomplete all as specified and directed.
70S&F 15 mm GI tubes medium grade with all fitting and fixed complete to walls, ceilings or laid infloors including taking up or down old steel tube complete all as specified and directed.
71S&F 20 mm GI tubes medium grade with all fitting and fixed complete to walls, ceilings or laid infloors including taking up or down old steel tube complete all as specified and directed.
72S&F 100 mm cast iron sanitary connection socket to fitwc out let complete all as specified and directed.
73S&F 100 mm cast iron sanitary connection S branch with branch 370 to 450 mm long excluding jointcomplete all as specified and directed.
74Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories).
75S & F of 110 mm dia(SWR) pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed
76S & F of 75 mm dia(SWR) pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed
77S&FPVC SWR (110) bends any radius comlete all as specified and directed.
78S&F 75 mm PVC (SWR) junction single, (singl T )(equal or unequal ), ordinary or inverted ( spigot or socket type ) or with paralle oval access doorsbranches complete all as specified and directed.
79S& F 110 mm PVC (SWR)vent cowl. Complete all as specified and directed.
80S&F 75mm PVC (SWR)floor trap, plain with grating including jointing with solvent cementcomplete all as specified and directed.
81S&F PVC(SWR) gully trap 125/110mm setting and jointing with solvent cement complete all as specified directed.
82S&F stack clamps out of 50mm by 5 mm flat iron and 16 mm dia round iron stays including bolts and nuts and securing ends of stays to wall or roofs for bore of 100mm complet all as specified and directed.
83S&F stack clamps out of 50mm by 5 mm flat iron and 16 mm dia round iron stays including bolts and nuts and securing ends of stays to wall or roofs for bore of 75 mm complet all as specified and directed.
84Dismantling of brick tiles laid bedded and pointed in any morter or brick tiles on roof , floors, channels, kerbs, aprons etc,cement concrete of any description & in any position not otherwise specifically provided for.
85Demolition of Mud/mud puska in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and directed.
86M&L For cutting out cracks to v-section in existing roofs or terraciv cleaning grouting with cement and sand slurry 1:3. complete all as specified and directed.
87M&L For cutting grooves in brick wall 75mm wide and 65mm deep & shaping horizontal face of groove with cement . complete all as specified and directed.
88M&Lfor PCC 1:3:6 type B-1(using 20mm graded stone aggregate) for providing cement concrete as levelling and roof kerbs or mud stops, including finishing the surface with grinder to receive the acrylic based water proofing material, rounded or chamfered on edges etc complete all as specified and directed.
89M&L for rendering or bedding layer15mm thick in cement mortar (1:3) cover concrete surfaces of roof, mixed with WPC 2% wt of cementinclduing finishing surfaces even and fair without using extra cement complete all as specified and directed.(Note: WPC will be measured and paid separately).
90M&L for preparation of new surface andapplying a coat of hot blown bitumen of grade 85/25 conforming to IS 702 over primed surface of roof slab @ 1.20 Kg/Sqm complete all as specified and directed.
91M&L for APP basedpolymeric water proofing membrane minimum weight 3 Kg/ Sqm and minimum 3mm thick reinforced with polyster non wove fabrick (Weight not less than 150gms/Sqm or as per IS),laid over hot bitumen surface by torched application with the strict supervision of manufacturers technical supervisor. Membrane shall be laid with 100mm side/end lap on prepared surface as per manufacturer instruction work shall be carried out strictly with the technical tradesmen and supervision of technical staff of manufacturer.complete all as specified and directed.
92M&L for renderingor bedding layer15mm thick in cement mortar (1:3) cover concrete surfaces of roof, mixed with linesed oil @ 3% wt of cementinclduing finishing surfaces even and fair without using extra cement inclusive linesed oil complete all as specified and directed.
93Dismentling of floor, hearth or wall tilingincluding cement mortar bedding (but not backing)complete all as specified and directed.
94M&L forceramic tilescoloured 7 to 8 mm thick(square/ rectagular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm in floors etc.including fixing with neat cement based approved chemical adhesive reqd for tilingas backing coat complete all as specified and directed. note; material of adhesive will be supplied and measured separately.
95M&L forNon Skid ceramic coloured tiles 7 to 8 mm thickjoint free (square/ rectagular) area of each tile exceeding 0.06 sq m but not exceeding 0.11 sqm ,in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchthe shade of tile and laid over and inclduing 15mm thick screed bed layer in CM (1:6) complete all as specified and directed.
96M&L for ceramic tilescoloured 7 to 8 mm thick (square/rectangular) area of each tiles exc. 0.11 sqm but not exc. 0.18 sqm, in skirting etc including fixing with neat cement based approved chemical adhesive reqd for tilingas backing coat complete all as specified and directed. note; material of adhesive will be supplied and measured separately.
97M&L for Glazed ceramic tiles in vertical surface 450x 300x7 mmthick joint lesstiles set and jointed in neat cement slurry and pointed in white or coloured cement to matchthe shade tile over and inclduing 10mm thick rendering in CM (1:4) complete etc. (1st quality/Premium Quality).complete all as specified and directed.
98Struking of existing PCC floor surface 5 to 10 mm deep picking,sweeping, clean and washing down with water to remove dust to receive cement mortar for tiling, complete all as specified and directed.
99Demolition of reinforced cement concrete any description and in any position not otherwise specifically provided for any description
100M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work;not exceeding 200mm thick (Horizontal or sloping)
101M&L for RCC type B1 1:2:4 to Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete
102Dismantling of stone slabs and tiles of any description or thickness in floors aprons etc including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
103M&L for18-20mm thick granite work table rubbed and polished for wall lining /kitchen platform over 12mm thick cement mortar 1:3 thick and pointing with white cement(1:2) using marble dustwith admixture of pigment to match with shade of granite complete all as specified and directed.
104Demolition of PCC in ground floor n.exc15cm thickness below or above ground levelcomplete all as specified and directed.
105M&L 40mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate) all as specified and directed.
106Plastic dividing strips, 1.5mm thick and ditto 38mm thick all as specified
107M & L for 75mm thick PCC 1:3:6type C-2 (using 40mm graded agg) for plinth protrction etc complete all as specified.
108Supply only liquidintegral water proofing compund. Make Dr Fixit/ Pidipfoor/ LW+.
109Demolition of brickwork or stone boulder masonry, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles all as specified and as directed.
110M&L for Cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in mass-concrete/foundation or floorcomplete all as specified and directed
111M&L for coloured machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-30 grade laid over including 1:6 CM 20mm thick sand cushioning including filling of joints with sand complete all as specified and directed.
112M&L for Brickwork with subclass "B" bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 of using class designation 100 of bricks in lieu of 75all as specified and as directed.
113Taking down cement plaster on brick or stone walls, etc, incl raking out joints, hacking for key, scrubbing down with water, etc & prepare to receive new plaster complete all as specified and directed
114M&L for 15mm thick rendering in CM 1:6 on fair faces of brick work, surfaces finished even and fair without using extra cement complete all as specified and directed
115M&L for 15mm thick rendering in CM 1:4 on fair faces of brick work, with mixing WPC @ 3% by wt of cement surfaces finished even and fair without using extra cement complete all as specified and directed
116M&L for rendering 5mm thick in CM 1:3 finished even and smooth with out using extra cement in ceilingcomplete all as specified and directed
117M&L for preparing new plaster surfaces of ceiling and applying two coats of oil bound distemper over coat of primer complete all as specified and directed.
118M&L wall care putty white 1.00 mm thick (to achieve smooth surface)for new plaster surface of wall complete. allas specified and directed.
119M&L for preparation of new plaster surfaces of walls and applying two coats of oil bound distemper over one coat of primer complete all as specified and directed by Engg-in-Charge.
120M&L for preparing new plaster surfaces of Walls and applying two coats of white wash over coat of primer complete all as specified and directed.
121M&l for Preparation of new plastered surface of wall and applying two coats of cement base paint over a coat of primer including balance area complete removal.
122M&L for complete removal of existing treatmenton ceiling surface and applying two coat ofoil bound distemper complete all as specified and directed.
123M&L for complete removing existing treatment on wall surface and applying two coats of oil bound distemper overover one coat of primer and applying 1mm thick putty on wall complete all as specified and directed by Engg-in-Charge.
124M&L for complete removal of existing treatmenton Walls surface and applying two coats of of cement base paint on wall surfaces complete all as specified and directed.
125M & L Preparation of old painted steel surfaces of any description,over 10 cm width or girth and applying one coat of synthetic enamel paint (ordinary tint), complete all as specified and directed.
126M & L for preparation of old woodenSurfaces of any description, over 10cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
127M&L for preparation andwriting letters or figures (block, Roman, Italic or Indian) n.exc 30 CM heinght on plaster/concrete wall/path over coat of ACE as matching with existing pattern complete all as specified & directed
128Cutting grass bushes, front and back sideof building complete.
129Cutting branches of trees and removal outside from MD land complete
130Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
131M&L for concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements with 1.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor with andincluding PVC concealed conduit of medium grade with all fittingsincluding Modular metal flush box minimum 1.6 mm thick, Modular white cover plate with frame, of required module at site, fixed with chromium plated screws and washers for switches and sockets, including 1.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dollyand including cutting chases in walls / floors for concealed conduitandmaking good disturbed surfaces area by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash complete all as specified and directed for the following:- Note: - Cutting chase to wall wherever required shall be included in the rate quoted for point wiring.
132(a) One light, fan, bell point controlled by one switch.
133(b) One 3 pin switch socket outlet point 5 Amps on same board with other switch.
134Ditto all as above as per Ser item No. 132.00 above but with 1.5 sqmm copper conductor cable for One 5 Amps socket outlet on independent board.
135All as per item No 132.00 above here in before but with copper conductor cable for one 3 pin socket outlet, 15 amp independent, with cable 2.5 Sqmm size.
136M&L for concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements with 4 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor with andincluding PVC concealed conduit of medium grade with all fittingsincluding Modular metal flush box, Modular white cover plate with frame, of required module at site, fixed with chromium plated screws and washers for switches and sockets, including 4 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dollyand including cutting chases in walls / floors for concealed conduitandmaking good disturbed surfaces by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash complete all as specified and directed for Power socket 15 Amps on independent board.
137M&L for Modular switch 1 way 6A, 1 module, flush button single pole, one way, complete as specified and directed by Engineer in charge.
138Supply and fixing Modular socket outlet 2 in 1, 5 pin, 6 Amps flush type white finish complete all as specifiedand as directed.
139M&L for Modular socket outlet 2 in 1, 6 pins 6A and 16A, combined 2 module, complete all as specified and directed by Engineer in charge.
140M&L for Modular switch 1 way 16A, 1 module, flush button single pole, one way, complete as specified and directed by Engineer in charge.
141S & F ceiling rose surface backlite 65x50mm 3 terminals complete.
142Supply and fixing lamp holder PVC body with back plate completeall as specified and directed.
143S&F Modular Fan step regulator, 120W - 2 module complete all as specified and directed.
144M&L forModular bell push 5 Amps 230 V, AC circuit complete all as specified and directed.
145M&L for call bell ding dong 230 V AC circuit complete all as specified and directed by Engr-in-Charge.
146Supply and fixing 4 Module Gang box including Modular socket outlet 16 Ampsfor AC, 240 Volts flush type white finish including plug top 20 Amps with modular piano type switch 20 Amps and LED indicator (RED) incl concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements with 4 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor with andincluding PVC concealed conduit of medium grade with all fittings and Modular white cover plate with frame 4 module to accommodate all theaccessories complete with internal connections, fixed with chromium plated screws and washers for switches and sockets, including 4 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dollyand including cutting chases in walls / floors for concealed conduitandmaking good disturbed surfaces by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash complete all as specifiedand as directed.
147Taking down old and u/s light fittings conventional type from wall surface / ceiling or any position and making good the disturbed surfaces all as specified and directed.
148Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
149Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete
150Supply and fixing LED Light fitting 1x12 watt bulkhead luminaire including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete.
151Taking down carefully unserviceable DB any type/size disconnecting and making good disturbed surfaces complete all as directed.
152Supply ,install, testing & commissioning of indoor type, wall mounted (with anchor bolts & nuts) compartmentalized type Meter Cabinet for provision and fixing arrangements of 4 nos. energy meters of overall dimension 1200mm (W) x 750mm (H) x 200mm (D) made out of 2.0 mm thickCRCASheet with front door having cut out duly covered with transparent polycarbonate / glass panel for viewing KWh meter / Timer and other door shall be opaque. All doors should have gasket and locking arrangement to meet ingress protection level IP-43. The cabinet shall be painted both internally and externally with powder coated paint (RAL 7032 : SIEMENS GREY) after necessary surface treatment. The cabinet shall be fabricated as per the drawing and comprising of following accessories :- (a) Four pole MCCB, 63 Amps with breaking capacity 16 KA having fixed thermal and fixed magnetic release and spreader link at both incoming and outgoing side.- 01 No. (b) Copper Bus Bar of size 25mm x 3mm duly mounted on FRP insulators and necessary drilling for 1 incoming & minimum 6 outgoing connections and duly covered with heat shrinkable PVC sleeves of standard colour code - 4 Nos. (c) MCB SPN 25 Amps, 10 KA - 4 Nos ( To be connected with 4 Nos Meters) (d) MCB SP 06 Amps, 10 KA -2 No ( For common lighting & Bldg Security Lights) (e) Analog time switch 16 Amp-01 No (f)LED indicating Lamps, 22mm with 3 Amps SP MCB-03 Nos. (g) 3 Way Bakelite strip type cable connector 30 Amps rating - 06 Nos (h) Dial type DIN rail mounting, Analog Time Switch 16 Amps / 230 Volts AC 50Hz, with battery back up,24 Hrs programmable type with 1 NO & 1 NC output contact.- 01 No. (for security light). (j) Internal wiringwith 1100V grade FRLS PVC insulated multi flexible copper wire of sizes duly crimped with copper lugs of suitable size & type all as mentioned below :- (i) MCCB to Bus Bar - 10.0 Sqmm copper (ii) Bus Bar to Cable Connector via KWh meter and MCB - 6.0 Sqmm (iii) Bus Bar to LED Lamp via MCB - 1.5 Sqmm
153Supply and fixing factory made epoxy powder coated distribution board SPN 12 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, stranded DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified & directed.
154Taking down carefully unserviceable MCB SP/SPN/Isolator of any rating/size.
155Supply and fixing MCB single pole 240 volt "B" curve 10 KA 5 to 32 Amps capacity all as specified and directed incl taking down old one.
156Supply and fixing MCB single pole & neutral 240 volt "C" curve 10 KA 25 to 32Amps complete all as specified and directed .
157Taking down old and u/s sub main wiring of 2/3 runs of any sizes from any position including, making good disturbed surface of wall ceiling etc all as directed.
158M&L for concealed sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6.0 Sqmm of voltage rating up to and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 25mm with all fittings and accessories, along with one run of PVC insulated, unsheathed, stranded copper conductor of size 6.0 Sqmm (green colour) as earth continuity conductor all as specified and directed. (Note : Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit)
159M&L for taking down carefully existing ceiling fan/exhaust fan from site before E/M repair work, keeping in safe custody in store forgreasing / oiling of ball bearings / bushes and making it for smooth and noise free operation and painting with Hi-Gloss synthetic enamel paint of approved shade by spray painting after filling cavities" and re-fixing after providing new fan clamp, nuts/bolts, washers, down rod as required and provision of 3 core copper flexible cable of size 1.0 Sqmm from ceiling rose to fan connector complete with writing of MES No. on the fan surface all as specified and directed.
160Supply and fix exhaust fan steel body, heavy duty, double ball bearing, Copper woundedcomplete with louvers shutter, 230 volt AC, single phase, 50 Hz, 1400 RPM, 300 mm sweepwith blades, steel frame complete all as specified and directed.
161Supply and fixexhaust fan made of sturdy Engineering plastic complete with louvers shutters , 250 mm sweep, single phase, 230 Volts AC,1200 RPM, ISI marked fixed properly at directed location with provisioning of suitable fixing/tightening arrangements and connecting/testing andincluding writing MES No complete all as specified and directed,
162Cutting the existing wall/removing existing steel bar to make a hole for fixing of ventilation fan through packing of wooden ply to support the ventilating/ air circulating fan including necessary nut and bolts of suitable size incl making good of disturbed surface complete all as directed by Engr-in charge.
163Supply & Fixing ceiling fan 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush less direct current (BLDC) motor, class of insulation : B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service Value ( CMM/W) minimum 6.00, Air delivery minimum 210 CMM 350 RPM ( tolerance as per IS : 374 - 2019), THD less than 10 % ,electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 degree C (max), insulation resistance more than 2 mega ohm, suitable for 230 V , 50 Hz, single phase AC supply, earthing etc including necessary connection with ceiling rose with 3 core 1.0 Sqmm PVC insulated round flexible cable and including writing MES No all as specified and as directed.
164M&L for taking down carefully existing geyser of any type and cap from site before E/M repair work, keeping in safe custody in store for servicing and painting with Hi-Gloss synthetic enamel paint of approved shade by spray painting after filling cavities, writing of MES No. and re-fixing with new hot and cold water connection as required incl provision of 3 core copper flexible cable of size 4 Sqmm complete with 15 Amps 3-pin plug top all as specified and directed.
165Disconnecting and taking down old serviceable Energy Meters of any type / capacity after noting down the reading from meteretc. and marking the Quarter No on each meter with permanent marker pen and depositing in MES store for safe custodyand writing MES No complete and re-fixing /reconnection in new meter cabinet all as specified and as directed.
166M&L earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick, buried directly in to ground ( earth pit) not less than 2.25 metres deep below GL with top edge of earth plate opt less attn. 1.50 m below ground levelsurrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, connected to GI lead wire of 4 mm dia.(7.50 m Long) by means of nuts, bolts and washers, check nuts of GIand protected by the GI pipe light grade 15 mm nominal bore(7.5 m long) for earth lead wire and watering pipe light grade of 20 mm nominal bore, 0.63 mm thick G I sheet funnel , wire mesh, earthing test pointetc complete including necessary earth work and excavation in any type of soil , PCC 1:2:4 type B1 earth pit and Precast RCC cover 65 mm thick duly reinforced with 6 mm dia. MS round bars @ 100mm C/C both ways, with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as describedin electric plate of SI Part I completeall as specified and directed and testing on completion. Note :- Ifthe desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
167Supply and fixMCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCBSPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link completeall as directed by Engineer -in- Charge.
168Supply and fix MCB SPN 40to 63 AmpAmps 240 volts 10 KA 50 HZ "C" curve complete all as specified and directed by Engineer in charge
169S&F factory made epoxy powder coated Distribution board (MCCB DB) VTPN 4 way vertical type, IP - 43 Protection made out of min 1.6 mm thick CRCA sheet, fabricated, metal double door fixed to wall and suitable for universal mounting and including 200 Amps rated copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removeable gland plated with knockouts and suitable for TPN MCCB 125/160 Amps as incomer and 12 SP or 04 Nos TP MCBS as outgoing complete all as specified and confirming to IS : 8623 complete all as specified and directed.
170Supply and fix Sub main wiring complete with two runs of 2.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through PVC conduit concealed /surfacein walls all as specified and as directed.
171Supply and fixSub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn throughnon metallic conduit concealed/surfacein walls all as specified and as directed.
172Supply and fix in repair MCCB 125 Amps, FP 415 volts 25 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge.
173Supply and fix in repair MCCB 100 Amps, FP 415 volts 25 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge.
174M&L in replacement sheet metalenclosure, single pole and neutralwith a two pin and earth plug and socket 240 Volts grade20Amps complete with onesingle poleMCB "C" series 20 A capacity complete all as specified and directed by Engineer in charge.
175M&L 25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in roof padding, benching existing roof slab to slope etc complete all as specified and directed.
176M&L for Non skid ceramic jointless coloured tiles 7 to 8mm thick (square/ rectangular) area of each tiles exceeding 0.11 sqm but not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed with white as coloured cement to match over and including 15mm thick screed bed in cement mortor (1:6) complete all as specified and directed.
177Dismantling of wall and ceiling boards (fibre, pulp, insulation. etc) or insulation boards/slabs/blankets, any thickness, includinguding cover fillets all as specified and directed.
178M&L for6 mm thick plywood, grade BWR, type BB, fixed with nails, fixed in repairs
179Providing & fixing ceiling with Semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles at all heightwith GRG (Glass fibre Reinforced Gypsum) False ceiling tiles of size 595x595 mm of approved texture design patterns having moisture content less than 2%, humidity resistance of 99%, NRC) .50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 Part4)-1970 and light reflectance of 85% (Minimum) to be laid in true horizontal level suspended on inter- locking metal T-Gridof hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main- T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600 mm to form grid module of size 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mmlong,8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L- shape level adjuster of size 85x25x2mm Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in- Charge. Note : (i) Ceiling tiles shall be authorised brand of make as specified in Appendix "B" to particular. (ii) Thickness og GI section shall not less be less than 3mm and shall be procured from the tile manufacturer. (iii) Section and hanging system shall have galvanising of minimum 90 grams per sqm and same make of tile. (iv) Work shall be executed by manufacturer"s authorised vendor.
180M & L cement concrete type C-1, 1:3:6 ( using 20mm graded stone aggregate), 50 mm thick ,in plinth protection laid in bays not exceeding 2 Sqm each and finishing even and fair ontop without using extra cement with 6mm wide joints throughout the thickness of plinth protection in concrete bays all as specifed and directed.
181Supply & fix 4.8 mm thick tint glass/pin head type for aluminium ventilators / window etc. complete, all as specified and directed
182Aluminium channel fix to glass infornt of PVC celuka board all as specified and directed.
183M&L for aluminium window (Powder coated ) three track with anodized aluminium frame sliding/openable including wheel powder coated of section 62.5x37x2.5 mm thick shutter with bottom & middle rail of section 112.5x37x2.5mm and style & top rail of section 83x37x2.5mm thick with centrally locking arrangement with lock rail of rebate including joints cleat fixing of builders hardware fittings necessary and gazing with 5.0mm thick ordinary plain glass including wire mesh shutter necessary fittings fixuters & aluminium snap beads complete. Notes : (i) Glass filling in panels to windowsshall be measured and paid for separately under respective item of this schedule as supply only (ii) Thickness of powder (epoxy polyster) coating shall not be less than 50 micron (iii) Shade/tint of powder coating (epoxy polyster) shall be as approved by GE. (iv) Frame shall be measured under respective item of this schedule.” (v) Stainless steel wire cloth measured and paid for separately under respective item of this schedule.
184M&L power coated anodised aluminium doors (sliding/ hanging type) with frame size 101.60 x 44.45 x 2.00 mm thick and shutter aluminium anodised and top rail 47.62 x 44.45 x 1.50 mm style 47.5 x 44.5x1.5mm, lock rail 83.50 x 44.45 x 1.50 mm and bottom rail 150.00 x 44.50 x 2.50 mm including necessary aluminium fittings like aluminium butt hinges 04 Nos, aluminium handle 150mm 02 Nos, aluminium tower bolts 200 mm 01 No, aluminium door stopper 01 Nos, jointing cleats glazing cleats, rubber packing, anodised aluminium shape beading screws etc with panelling in two parts with 12mm thick prelaminted particle board in lower panel and 5mm thick tinted glass in upper panels including all fittings & fixture complete all as specified and directed.
185Hacking out old broken glass (any thickness, size, quality or description) from wooden frames, glazed with putty or fixed with beadscomplete all as specified and as directed.
186Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cmcomplete all as specified
187PCC 1:2:4 type B-2 (Using 40mm graded stone aggregate) as fdn filling and mass concrete for post holes.
188M & L chequered cement concrete outdoor tiles of size 30cm x30cm x 20 mm thick screed bed in CM 1:6 set jointed and pointed in neat cement slurry and pointed with coloured cement to match.
189M&L for steel work in tubular trusses including special shaped washer etc completeusing ERW or induction butt welded tubes conforming to I.S 1161-1979 at grade st 240.complete all specifiedas directed.
190S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Confirming to Fe-410- W(GdeE-250) quality-B etc complete all as specified and directed.
191Preparation of new surfaces of steel of any description over 10cm grith or width, not otherwise described with one coat of red oxide followed by two coats of synthetic enamel paint all as specified and directed.
192M&L for rendering 10mm thick in cement mortar (1:4) cover concrete surfaces of roof, mixed with @ 200mlliquid water proofing compound by 50Kg weight of cement (1 bag)as per manufacturerrs instruction inclduing finishing surfaces even and smooth without using extra cement complete all as specified and directed. (WPC shall be measured and paid separately).(Note: WPC will be measured and paid separately).
193M&L Liquid water proofing compound
194Material and labour for roof treatmentwith reinforced elastomeric liquid waterproofing membrane of 400-micron thickness (four layer)(Each layer of 100 micron,another layer shall be laid only after complete dried of Ist layer) having SRI of 130, tested as per ASTM E 1980 (with Solar Reflectance and Thermal remittance tested as per ASTM C 1549 and ASTM C 1371 respectively).The coating should have water absorption less than 1% as per IS : 101 (P-7/Sec-1) 1989 with the ability to resist heat upto 1200 C as per IS : 101 (P-7/Sec-3) 1990 having VOC less than 1g/ltr as per ASTM D 3960 and should have excellent resistance to transmission of ponder water up to 3.5 bars of pressure for 7-days.It should also be resistant to Ammonia solution, Sodium nitrate, Sodium hydroxide along with water and soap solution as per IS : 101 (P-7/Sec-2) 1990.The waterproofing membrane will be laminated with 25-40 micron thick transparent Nano modified composite cross linking polymeric coating with aminimum of 40% solid content as per IS : 101 (P-8/Sec 6) 1993 and also should pass impact test as per IS : 101 (P/5/Sec-3) 1988 along with having dust and water repellent and anti grafting property passing scratch hardness test of 500 g as per IS : 101 (P//Sec-2) 1988.The polymeric coating should have a self cleaning and easy to clean property with excellent weather stability and DPR (Dirt pickup ratio).Surface preparation includes pressure wash cleaning to remove all dust, fungus, etc. with pressure washer after repairing the existing roof having old bitumen membrane by filling cracks, potholes, holes with waterproofing compound having compressive strength as per IS-4031 part-6-1988 & permeability of water as per IS 2645-2003.The work will be done under the supervision of the Engineer-in-Charge by Graco airless machine and OEM should be an IGBC (Indian Green Building Council) member & GRIHA Council Certified.The coating thickness and the methodology of application shall strictly be as per the manufacture’s specifications and as approved by the Engineer-in-Charge.The manufacturer shall give a guarantee for the performance and durability for 8-years. Note :-Make : Dr. Fixit, Pildlite, Sika, M/S Starsshield Technology Pvt. Ltd.).
195Supply and fix LED 2 X 2 ft backlite surface mounted fitting 36/40 Wattsnot less than 3200lm with Metallic CRCA powder coated body with high efficiency opal/PMMA diffuser with system efficacy > 80 lm/W, CRI>80, color temperature >5700k, IP 20, Power factor<0.95, THD<10%, 50000 burning hours ,Ambient temperature 0 to 500 DegC, Driver should meet IEC complaint for safety, with voltage variation range of 150-270 V and surge protection of 2.5 KV including necessary fixing arrangementsfixed completeallas specified and directed.
196Supplyinstallation commissioningandtesting hi wall split units indoor and outdoor complete with cordless remote control unit and with in built air ioniserand plasma filterfor better indoor air quality with minimum 5 star rated, invertor typeand capacity 2ton including breaking necessary hole in wall any type for fixing indoor and outdoor unit and making good disturbed surfaces with cement mortar and paint to match existing surface, all as required including necessary connections complete all as specified and directed .
197Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled outdoor type,Built-In Thermal Overload Protection,Low & High Voltage cut-o? Protection & designed for input variation between 150 V to 285 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA ,all as required including necessary connections complete all as specified and directed
198Excavation in hard standing for crossing the road as per the authorized width for taking out/laying/cleaning/repairingof CI/GI pipe lines all as directed including making good the road cut to match with the existing surface either with bituminous macadam or with PCC 1:2:4, type B-2(using 40mm graded crushed stone aggregate) complete all as specified and directed.
199Supply and lay steel water tubing GI medium grade ISI marked with all fittings laid in trenches or fixed to wall etc complete for the following sizes:-Make: Jindal/Prakash/Swastik Note :- Excavation and earth work will be measured and paid separately.
200(a) 50 mm dia bore
201(b) 40 mm dia bore
202(c) 20 mm dia bore
203S&F Gun metal gate valve ISI marked with iron wheel head screwed both ends for iron pipes and fixed for the following sizes including taking down of unserviceable gate valves.Make : Zoloto/Seico/Jindal/Upadhaya/Venus
204(a) 80 mm bore
205(b) 20 mm bore
206Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail