Tender For Special Repair To Bldg No T-21, Special Repair To Bldg No T-19 (Or Living Accn), Provn Of Pathway With Drainage At Children Park And Provn Of 01 X High Mast Light At Dinjan Mil Stn Under Ge Dinjan, dinjan-Assam

Military Engineer Services-MES has published Tender For Special Repair To Bldg No T-21, Special Repair To Bldg No T-19 (Or Living Accn), Provn Of Pathway With Drainage At Children Park And Provn Of 01 X High Mast Light At Dinjan Mil Stn Under Ge Dinjan. Submission Date for this Tender is 17-05-2024. Building Work Tenders in dinjan Assam. Bidders can get complete Tender details and download the document.




Tender Notice

43252110
Tender For Special Repair To Bldg No T-21, Special Repair To Bldg No T-19 (Or Living Accn), Provn Of Pathway With Drainage At Children Park And Provn Of 01 X High Mast Light At Dinjan Mil Stn Under Ge Dinjan
Open Tender
Indian
Assam
dinjan
17-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Special Repair To Bldg No T-21, Special Repair To Bldg No T-19 (Or Living Accn), Provn Of Pathway With Drainage At Children Park And Provn Of 01 X High Mast Light At Dinjan Mil Stn Under Ge Dinjan

Key Value

Document Fees
INR 500 /-
EMD
INR 86000.0 /-
Tender Value
INR 43 Lakhs /-

Attachment

FileName File Description File Size
0d531b14-39f4-48c0-a4c8-579af13a54e8.html Tender Notice 0 KB
BOQ_729135.xls Tender Document 0 KB
CREDIT8649.pdf Tender Document 0 KB
TENDERDOCUF8649.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: SPECIAL REPAIR TO BLDG NO T-21, SPECIAL REPAIR TO BLDG NO T-19 (OR LIVING ACCN), PROVN OF PATHWAY WITH DRAINAGE AT CHILDREN PARK AND PROVN OF 01 X HIGH MAST LIGHT AT DINJAN MIL STN UNDER GE DINJAN
Sl. No. Item Description
1Demolition of cement concrete (un reinforced) in ground floors and paving n. exc. 15 cm thickness (below or above ground level) removing rubbish off the premises etc complete all as directed
2Demolition of brick work in cement mortar incl all quoins, arches, pillars etc, but excluding ashler facings, dressed stonework and precast concrete articles complete all as directed.
3Taking down chowkhats or frame with shutters (without taking off shutters from the frame) not exceeding 1.50 Sqm each complete all as directed.
4Taking down chowkhats or framewith shutters (without taking off shutters from frames) exceeding 1.5 Sqmbut not exceeding 4.5 Sqm each complete all as directed.
5Dismantling timber scantlings 40 sq. cm and over in section, in any position of unframed work, complete all as specified and directed.
6Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
7Dismantling Asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings any thickness, complete all as specified and directed.
8Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs of any thickness including cover fillets complete all as directed.
9Materials and labour forplain cement concrete (1:3:6) type C1(20mm graded stone aggregate) as in cills, hold fast, steps, seismic and othersimilar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60cm in height , copings, kneelers, apex stones, bed plates, kerbs including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
10M&L for brick work with sub class "B" bricks straight or curved on plan exc 6 meter mean radius built in cement mortar 1:6 complete all as specified and as directed.
11M&L for brick work with sub class "B" burnt clay bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed.
12M&L for second class hardwood plain fillets. square, rectanglular or triangular in section, clean swqn, secured with nails or bands size exc 13 and n. exc 25 sqm cm complete all as specified and as directed. .
13S&F Solid PVC wall lining consisting of 5mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing.
14M&L for second class hard wood timber scantling, clean swan as in frame work, fixed with nails complete all as specified and directed.
15Supply and fixing 30mm thick second class class hard woodglazed and skelton shutter, open rebated and prepared to receive glass, gauze etc, (without sash bar), edges of framing plain, chamfered or rounded,fitted with cut and mitred beads for securing glass exc., size of members of shutter as specified in SSR part-I, sec 8 clause 8.24(a), complete all as specified and directed.
16Supply and fixing 35 mm thick second class hard wood plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats, complete all as specified and directed.
17Supply and fixing solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube, suppling & fixing in opening as per specification & drawing, complete all as specified and directed.
18S&F for Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing in SSR Part II 2020 complete all as specified and as directed
19S&F for aluminium anodized glazed ventilators with frame of standard section and grill including provision of glazing with 5 mm thick glass fixed to frame, rubber beading , handles and tower bolts etc all as specified and directed as in repairs including removing of old steel windows
20S&F Anodised aluminium windowsliding shutters three track way type without sash bars, aluminium sections weighing 0.55kg/m including necessary joining cleats, glass clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings, such as peg stays 150mm long (1 No) hinges type B-21, 100mm long (2 Nos) suitable handle (1 No) with complete accessories including glass, wire mesh,anodised aluminium frame (chowkhats) and all accessories and fittings etc all as directed by Engineer-in-Charge.
21Supply and fixing Aluminium anodized barrel tower bolts of extruded section, 200 mm long, complete all as specified and directed.
22Supply and fixing for 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and directed.
23Supply and fixing mild steel butt hinges, medium grade, 100 mm size, complete all as specified and directed.
24S&F, 100 mm long butt hinges, extruded aluminium alloy with galavanised mild steel hinge pin, anodised and fixed , type C-21
25Supply and fixing extruded aluminium alloy handles, fabricated type, anodized, 150 mm size , complete all as specified and directed.
26Supply and fixing extruded aluminium alloy handles, fabricated type, anodized, 125 mm size , complete all as specified and directed.
27S&Fin repair harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and directed.
28Supply and fixing galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staplescomplete all as specified and directed.
29Supply and fixing 4.8 mm thick sheet glass, ordinary quality and glazing with oil putty in squaresn.exceeding 0.50sqm in each pane , complete all as specified and directed.
30S&F for mild steel window guard bars, plain, let in and fixed independently in wooden frames, L or T section, supports for shelves etc., and similar articlesconforming to Fe 290 Gde E-165 including drilling holes complete all as specified and directed.
31Supply and fixingfor Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1998 grade St.-240
32S&Fpressed steel frames for doors local work shop made of size 125x60mmwith one or more rebates using cold rolled commercial mild steel sheet of 1.2mm thick including providing and fixing necessary lugs, 100mm butt hinges, lock strike plate,shock absorber etcand including PCC filling of hollow section using plain cement concrete (1:3:6) type C1 complete all as specified and as directed.
33S&F for aluminium anodised snap grid frame work of size 605mm x 605mm frame work for ceiling with aluminium tee section of size 23.5mm x 26.4mm x 1.4mm thick and aluminium angle section of size 36.5mm x 25mm x 1.4mm thick, for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long including 4 mm thick non asbestos E-board (plain), HSPC fixed to frameincluding providing two coats of distemper oil emulsion complete all as specified and as directed.
34Supply and fixingPre-painted galvalume aluminum zinc coating (AZ-150) GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
35Supply and fixing Pre-painted galvalume aluminum zinc coating (AZ-150) GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws , complete all as specified and directed.
36M&L for 18/19 mm thick prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work including teakwood lipping 6 mm thick fixed with nails including taking down old unserviceable complete all as specified and directed. .
37Dismantling floor hearth or wall tiling and stone slabs including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises etc complete all as directed
38Materials and labour for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, including 15 mm thick screed bed or bedding in cement mortor (1:6) and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed.
39Materials and labour for non skid ceramic colouredtiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11sqm but not exceeding 0.18 sqm, (400x400x7mm) as in skirting. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10mm thickbacking coat in cement mortar (1:4) , complete all as specified and directed.
40Materials and labour for Non-skid ceramiccoloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm(300x300x7mm),over 15mm thick screed bed in CM 1:6 on floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchthe shade as specified and as directed.
41Materials and labour for coloured 450x300x7-8 mm thick glazed ceramic tileson vertical surfaces such as skirting,dado and risers to steps etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, over and including 10mm thickbacking coat in cement mortar (1:4) , complete all as specified and directed.
42M&L for Vitrified Ceramic tiles light shade (600x600) 10mm thick (Square/rectangular) polished area of each tile not exceeding 0.36 sqm of light shed in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cemeent to match in shade of tiles over and including 15mm thick screed bed or bedding layer of cement morter (1:6) for laying of floor finishes complete all as specified and directed. irected.
43M&L for prepolished, chequered cement concrete tiles of size 25cmx25cmx22mm thick, as in floors etc,including 20 mm thick screed bed or bedding in cement mortar (1:6) and set and jointedin neat cement slurry and pointed in grey cement and pigments to match with the shade of tiles complete all as specified and as directed.
44Material and labour for 75 mm thick plain cementconcrete (1:3:6) type C2 using 40 mm graded stone aggregate as in sub-base of floors, plinth protection etc. finished the surface of concrete fair, even and smooth without using extra cement, complete all as specified and directed.
45Materials and labour for 25 mm thick PCC (1:2:4)type B0 (using 12.5 mm graded stone aggregate) as in floors finished even and smooth with using extra cement, complete all as specified and directed.
46Taking down cement plaster or lime plaster on walls /ceiling of any description from concrete or brick wall etc including raking out joints, hacking for key, scrubbing down with water and disposing off the retreived debris as directed including necessary scaffoldings etc complete all as directed
47M&L for rendering 10 mm thick on fair faces of external wall of brick work or stone surfaces in two layers (10 mm and 5 mm thick) in cement mortar (1:4) using water proofing compound in top layer andfinished even and smooth without using extra cement complete all as specified and directed. Note:(water proofing compound measured as separately)
48M&L for rendering 15 mm thick of internal wall on fair faces of brick work or concrete surfaces in cement mortar in (1:6) andfinished even and smooth without using extracement complete all as specified and directed.
49Materials and labour for rendering 5mm thickin cement morter (1:3) on ceiling surfaces, finished even and smoothwithout using extra cement, complete all as specified and directed.
50Supply only Water Proofing Compound of approved make.
51Taking down plastering on lathing other than wire netting without removing lathing, in lime/cement mortar (One side only measured in cases where both sides are plastered)
52M&L for GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste fixed with tinned tacks of wire staples complete all as specified and as directed.
53M&L for rendering 18 mm thick(12+6) externally one side of lathing in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement, mixed with integral water proofing compound @ 2% by weight of cement on top layer surface complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item).
54M&L for rendering 12 mm thickon one side oflathing in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement complete all as specified and directed.
55Materials and labour for preparation of newly plastered surfaces of ceiling and applying three coats of white wash,complete all as specified and directed.
56Materials and labour for complete removal of existing treatment from wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots including washing down with water etc. applying two coats of oil bound distemper with roller over one coat of primer of approved colour over and including 1mm thick wall cate putty after preparation of surface completeall as specified and directed.
57Materials and labour for complete removal of existing treatment from wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots including washing down with water etc. applying two coats of cement base paint over one coat of primer of approved colour over and including 1mm thick wall cate putty after preparation of surface completeall as specified and directed.
58M&L for preparation of newly plastered surfaces of external walls and applying two coats ofcement base paint over a coat of alkali resistant primer complete all as specified and as directed.
59Materials and labour for preparation of new plastered surfaces of walls and applying two coats of oil bound distemperand 1mm thick wall care putty of approved colour with roller over a coat of primerafter preparation of surface completeall as specified and directed.
60Materials and labour for preparing of new wooden surfaces of any description , over 10 cm width or girthand applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
61Materials and labour for preparing of new steel surfaces of any description , over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
62Material and labourfor forming 12mm thick expansion joints in 100 mm thick concrete slabs, filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’, complete all as specified and directed.
63Bringing approved earth (as approved by Garrison Engineer) from sources outside defence land including all cost such as royalty if any, transportation,taxes if any etc(exeeding 5km but not exeeding10 km) complete all as specified and as directed.
64Material and labour for hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface with Broken stone or boulders complete all as specified and as directed.
65Supply only fine sand cushioning for laying under paver block.
66Material and labour for 60mm thick Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size conforming to IS 15658- 2006 M-35 grade, laid as directed to any shape. Complete all as specified and as directed
67Material and Labour for 100mm thick PCC 1:4:8, type D2 (using 40mm graded crushed stone aggregated) as in sub base of floor complete all as specified.
68Supply and fixing PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed.
69Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
70Materials and labourfor surface point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 1.50 sqmm green in colour as earth lead, drawing through in and including PVC casing caping of size not less than 20mm, with all fittings & accessories including provn of MS sunk terminal box of appropriate size suitable for switch fixed flush to wall for mounting switch, sockets, fan regulators etc with 3mm thick hylum sheet top cover with screws & cup washers for one light / fan point / call bell complete. NOTE : Cost of making good the disturbed surfaces (if any) matching with the existing surface is deemed to be included in the unit quoted rates. all asspecified and directed.One light/fan/call bell point controlled by one switch one way 5 Amps
71All as per Item No.70 above but for One 2/3 pin socket outlet 5/6Amps on independent board
72All as perItem No.70 above but forOne 2/3 pin socket outlet 5/6 Amps on the same board with other switches.
73All as perItem No.70 above but for one switch socket combination 15/16 Amps on independent board with cable 2.5 sq mm size and earth wire 2.5 sqmm
74Supply and fixingSwitch piano, flush type, single pole, one way switch5 Amps.
75S & Fsocketoutlet2 in 1, 5 Amp flush type complete all as specified all as directed.
76Supply and fixing switch socketcombination 2 in 1,5 Amps flush type.
77Supply and fixing switch socket combination multipurpose 5A/ 16Amps, 5 in 1, flush type.
78Supply and fixing ceiling rose surface PVC 3 terminals 25x50mm all as directed.
79Supply and fixing electronic step regulator (speed regulation in 5 steps) suitable for ceiling fan 1200 sweep/1400 mm, 120 Watt complete all as specified and directed.
80S&F for lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
81S&F in repair LED Bulb of 09 Watt complete all as specified and directed by Engr -in Charge.
82S&F new 20 W surface and wall mounted LED Batten with polycarbonate housing and intigrated complete including taking down and complete all as specified and as directed.
83S&F for 25 Watt LED building security light new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens with Toughned Glass having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08 including all fixing arrangement and complete all as specified and as directed.
84S&F Recess mounted deep drawn CRCA housing with higher power LED Seamless front frame with flat white hight transmission acrylic cover all as specified and directed by Engr in charge.
85S&F in repair factory made board distribution (DB)double door in sheet metal enclosure with common bus bar at incomming end, single pole & neutral,8 way, 240 Volts suitable for housing MCBsincluding complete all as specified and as directed.
86S&F forMCB "C" curve double pole 6 to 32 Amps with breaking capacity 10 KA.
87S&F for MCB "C" curve single pole 6 to 32 Amps with breaking capacity 10 KA.
88Taking down old unserviciable submain wiring from PVC casing caping/concealed conduits upto 10 sqmm complete all as specified and direted by Engr-in-charge.
89Materials and labourfor surface sub main wiring withtwo single core stranded copper conductor, FRLSPVC insulated cable 1100V grade, 6 sq mm, drawn through and including suitable size of non-metallic PVC casing caping with6 sqmm copper conductor cable as earth conductor and conduit accessoriesincluding connecting up complete all as specified and directed. Note:- Two runs of main cable,one run of earth continuity conductor cable and one run of PVC conduit will be measured as one unit for payment purpose.
90M & L earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to 4.00 GI wire by means of bolts and nuts checknuts and washers of galvanised iron or steel all as specified and shown in elecrical plate no 3 of SSR part 1 including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 80 mm dia 150 mm long reinforcement,watering funnel,40 mm dia light grade for protection of earth electrode 20 mm dia for watering all as specified and directed and tested on completion.
91Supply & Laying or Fixing or Passing through Pipe, XLPE insulated, Armoured, Electric Power UG Cable (Heavy Duty) with Aluminium Conductor, 1100 Volt Grade, Nominal Cross-Sectional Area 10 sqmm 2 core and Testing, including Brass Compression Cable Gland, Terminal Lug, etc including taking downcomplete all as specified and as directed.
92Taking down existing old fluorescent tube light fittings/ bulk head light fittings/ ceiling light fittings/ building light fittings including lamp any capacity, any type complete all as specified and as directed.
93Taking down main switch/MCB DB/ sheet metal enclosure by disconnecting the electric supply including MCB/MCCB/Cut out etc. any type and size complete all as specified and as directed.
94Taking down carefully serviceable ceiling fan/exhaust Fan deposit in safe custody ,after repair work fix in original position after minor repair complete all as specified and directed.
95Supply & installation testing and commissioning of symmetric type Galvanized steel high mast lighting system of 16 meter in length in two section, 3 mm & 4 mm section thickness, top dia 150 mm, bottom dia 360 mm, with AISI 3161 steel wire rope 7/19,6 mm dia system 2 for wich and 3 for lantern carriage, including of timer pannel, complete all as specified and as directed including following :- (a) Sustain upto wind speed of 180 Kmph (b) Non Flame Proof integral Motor. (c) Movable lantern carriage. (d) Double drum Winch. (e) 6 mm 316 Grade S S Hoisting Ropes of 7/19 construction. (f) Trailing Cable –1 per mast (5 Core 2.5 Sq mm) (g) Lightning Finial , Anchor Plate & Template (h) Accessories like Plug and Socket, GI Nut bolt with double washer,wiring cable for fixture, flexible conduit, copper lug, PVC tape, Cable tie etc (j) Foundation Bolt & Nuts T & P for fixing withits allied accessories as per OEM. System is suitable for loading 08 nos 350 w LED lights (k) Installation, Testing & Commissioning, Casting of foundation for High Mast & Panel @10T/sqm soil bearing as per OEM. (l) Earthing for High Mast and Timer panel, Power Supply up to the Panel & Cable laying, Providing Power Cable from High Mast to Panel. Note: Installation should be complete in presence of OEM Rep
96Supply and fixing of LED aviation light complete all as specified and directed.
97M&L for Earthing complete with GI earth plate electrode of size 600x600x6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI earth strip of size 32 x 6 mm earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel,protected by galvanized iron pipe 40mm bore (Medium grade) allas directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel,wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed . Note:GI strip upto 7.5m including testing consider in this item.
98Supply installation, commissioning and testing including providing all necessary electrical connection, LTpanel, outdoor type CPRI approvedfactory made out of3.15 mm thick MS sheet of size 0.6m x 0.6 m x 0.5m deep having hinge opening arrangement in front and back side and bottom frame made out of angle iron of size 50x50x6mm thick and 04 Nos legs 0.5 meter length with cable entry and exit circular hole with cable gland & gasket at bottom including painting to all internal and external exposed steel surfaces with powder coating paint (5 stage process) with duly fixed in ground with necessary PCC foundation (1:2:4) type B1, with danger notice plate, street light panel of 1.6mm thick mild steel sheet, vitereous enamelled (white), with letters, figures and conventional skull and bones in signal red colour, fixing lugs, bolts, screws etc complete all as directed by the Engr-in-Charge and comprising of the following accessories complete including following accessories :- (a) Aluminium bus bar suitable for 200 Amp 0.5 mtr long fixing on suitable capacity and size insulators ---04 nos , (b)100 A MCCB incommer, (c) Phase indicator lamps (RYB) -set of 3, (d)Internal Wiring Note : Cost of foundation to be included in the quoted price.
99Supply and fixing LED flood light 350 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.
100Excavating in trenches n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
101Returning filling in with approved excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
102Removing excavated soils to a distance not exceeding 50 metres and depositing where directed at a level nexc. 1.5 metre above the starting point complete all as specified and directed.
103M&L Sand Cushioning (dry) in Trenches for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thick -ness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed.
104Material & Labour for common burnt clay building bricks (locally available best quality), sub-class ‘B’ designation 75 of suitable size available in market to cover LT underground cables, laid dry and flat abutting each other with gaps not exceeding 10mm including taking down old unserviceable bricks complete all as specified and directed.
105Supply & Fix in repairs, for GI pipe light grade with all fittings complete grouted in ground all as specified for 40 mm bore of pipe laid in trenches/fixed with poles/laid in road/plinth/floor for protection of cable complete all as specified and directed.
106Supply and laying XLPE insulated PVC inner sheathed, armoured with galvanized steel strip or wire heavy duty underground cable withstranded aluminumconductor 1100 volt grade of size 16 Sqmm 4 Core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete all as specified and directed including taking down old unserviceable XLPE cable with brick protection andcomplete all as specified and as directed.
107M&L for horizantal boring/drilling hole mannual under the road in soft/loose soil without cutting/disturbing the existing road and inserting GI pipe 80/50/40/32mm bore for drawing the cables complete all as directed and specified. Note: (i) Cost of acessories required for making hole/bore deemed to be included in the quoted rate.(ii) GI pipe has been measured and paid separately.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail