Tender For Construction Of “Unity Mall” In The Premises Of Co-Optex, Egmore, Chennai Under Scheme For Special Assistance To States For Capital Investment (Part-Vi) 2023-2024, egmore-Tamil Nadu

Public Works Department-PWD has published Tender For Construction Of “Unity Mall” In The Premises Of Co-Optex, Egmore, Chennai Under Scheme For Special Assistance To States For Capital Investment (Part-Vi) 2023-2024. Submission Date for this Tender is 30-04-2024. Building Work Tenders in egmore Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

43249412
Tender For Construction Of “Unity Mall” In The Premises Of Co-Optex, Egmore, Chennai Under Scheme For Special Assistance To States For Capital Investment (Part-Vi) 2023-2024
Open Tender
Indian
Tamil Nadu
egmore
30-04-2024

Tender Details

Construction Of “Unity Mall” In The Premises Of Co-Optex, Egmore, Chennai Under Scheme For Special Assistance To States For Capital Investment ( Part-Vi ) 2023-2024

Key Value

Document Fees
Refer document
EMD
INR 10766000.0 /-
Tender Value
INR 215.12 Crore /-

BOQ Items

Name of Work : Construction of “Unity Mall” in the premises of Co-optex, Egmore, Chennai under Scheme for Special Assistance to States for Capital investment (Part-VI) 2023-2024
Sl. No. Item Description
1Installation Charges inclusive of Transportation to site and the Boredpile equipment employed for the works including setting up of pile driving equipment with all accessories and tools at each of the pile location based on the sequence of operation approved by the departmental Engineers irrespective of the location and distance involved in movement of pile driving equipment etc., complete.
2Installation of Verticalbored cast in situ RCC piles of basic length 20 RMin all types of soil with M30 Grade using Ready Mix Concrete (Sulphate resistant Cement), Supply and erection of reinforcement, shoe, fabrication, including cost of binding wire, cutting, tying, welding and placing the reinforcement cage in correct position, driving and removing the temporary casing pipe of full depth, shifting the plant and equipments from one point to another, carryingout any ancillary work adjacent to piling work, trimming the concrete above cutoff level, cleaning the debris and levelling the site etc, as directed by the Departmental Engineers.The Rig capacity,height of Towerand length of casing pipe etc., must be adequate to take care of change in soil profile. The length of pile for payment shall be measured from top of shoe to the bottom of the pilecap.Testing of Concrete as specified in IS 456/2000 acceptance criteria as per clause 16.1. Frequency of testing as per 15.2.2. Testing to be conducted at both the ends at site as well as RMC plant. Pile driving depth should be decided by the departmental officers at site.
3600mm dia pile having longitudinal main reinforcement of 8Nos 20 # diawith helical reinforcement at 10mm dia at 200mm c/c with inner rings of 12mm dia @ 1000mm c/c with lifting hook of 12mm dia at required length
4900mm dia pile having longitudinal main reinforcement of 16 Nos 20 # dia with helical reinforcement at 10mm dia at 150 mm c/c with inner rings of 12mm dia @ 1000mm c/c with lifting hook of 12mm dia at required length
5750mm dia pile having longitudinal main reinforcement of 12 Nos 20 #, with helical reinforcement at 10mm dia at 200 mm c/c with inner rings of 12mm dia @ 1000mm c/c with lifting hook of 12mm dia at required length
6Initial Load Test as per IS 2911 Part IV 1985 including cost of single pile (250% of pile capacity), labour, reinforcement charges and all other incidential charges including excavation, shoring, strutting, dewatering etc. as necessary hire charges for jacks, measuring devices, Structural Frame work for platform, Kent ledges etc, as required and providing pilecap.
7Routine load test as per IS 2911 part IV 1995 (150% of pile capacity) including labour charges for jack, measuring devices, structural frame work plot form, kent ledges etc., as required and as directed by the departmental officers etc. complete.
8Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and refilling the sides of foundation with excavated sand or earth in layers of not more than 15cm thick well rammed water consolidated and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification.
9Earth work open excavation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. Wi
10Upto 2m depth
11From 2-3m depth
12From 3-4m depth
13From 4-5m depth
14From 5-6m depth
15From 6-7m depth
16From 7-8m depth
17Conveying and Collecting the excavated earth away the same to outside by lorry to a lead of not less than 10km limit including loading and unloading charges and dumping in low place and levelling etc., complete complying with standard specification and as directed by the departmental officers
18Supplying and filling in foundation, basement, etc with filling M.Sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
19Supplying and filling in foundation, basement, etc withstone dust in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
20Cement Concrete 1:5:10 (One Cement, Five sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation & Flooring including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification
21Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)
22Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid)
23For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.
24For plane surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc.
25For plane surfaces such asrectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.
26Providing additional strutting to centering of RCC slabs of plain surface for every additional 1.0 metre height or part thereof but not less than 30 cm, over the initial 3.00 metre height from floor level using casurina props of 10cm to 13cm dia including cross bracing etc., complete complying with standard specification and as directed by the department officers.
27Constructing cast-in-situ RCC diaphragm wall by providing and laying machine batched, machine mixed, self compacting, ready mix reinforced cement concrete,tramie controlled of M40 grade using minimum cement content of 440kg / m3 of concrete including providing and mixing required admixtures in recommended proportions as per IS:9103 as approved by the Engineer in charge for achieving 150-200mm slump for diaphragm wall having thickness as per approved structural design not exceeding 600mm in panels of required depth and lengths as aper approved drawing including constructing necessary guide walls as required and as specified including boring in all kinds of soils and rocks, including working in or under water / liquid mud, in foul conditions and pumping or bailing out of water and removing slush, including disposal of earth / rock / slush etc., for all leads and all lifts including preparing, providing and re-circulating bentonite slurry in the trench as and when required for all depths, including agitating bentonite slurry during trenching etc., providing and fixing stop ends or form tubes, upto the required depth of diaphragm wall including extracting the same after casting,including chipping off the bentonite adulterated concrete or unsound concrete upto the cut off level for obtaining the sound concrete, dressing undulations on the exposed face of diaphragm wall after excavation by chipping / chiseling etc.,including filling the depression / cavities with sound concrete etc., complete and as directed by the Engineer in charge, including providing recess for bearing plates and fixing insert boxes for inclined rock anchors etc.,
28Providing and laying in position, Standardised Concrete Mix M-40 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 440 kg/m? and maximum water cement ratio of 0.40, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5136 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers.The coarse and fine aggregates to be used should comply with the requirements of IS Standards.(No separate payment will be made by the Department for the excess usage of materials).
29In Foundation and Basement
30Basement floor 1
31Basement floor 2
32In Ground floor
33In First floor
34In Second floor
35In Third
36In Fourth floor
37In Fifth floor
38In Sixth floor
39In Seventh floor
40In Eight floor
41In Nineth floor
42In Tenth floor
43Providing and laying in position, Standardised Concrete Mix M-20 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 440 kg/m? and maximum water cement ratio of 0.40, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5136 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers.The coarse and fine aggregates to be used should comply with the requirements of IS Standards.(No separate payment will be made by the Department for the excess usage of materials).
44In Foundation and Basement
45In Ground floor
46In First floor
47Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification.(Contractor has to make his own arrangements for the supply of steel and binding wire)
48Post Tensioning Work:Designandexecutionofposttensioningwork,including decoiling, the strands, cutting to the required lengths, supplying,layingofHTstrandssheathing(GIcorrugated ducts 0.3mm thick) jointing with couplers and inserting the strands, profiling, fixing liveend anchorages, including supply ofstressinganchorages,suitablefor5-5&5-4tendons, grout vents, making dead end anchorages, including flowering the strands, fixing tendon support bars, supervising the fixing of antibursting reinforcement, stressing the cables, end trimming, grouting the cables, with cement slurry, mixed with admixtures with required tools, plants, and machineries, and consumables etc.(Shuttering, concreting & reinforcement steel shall be paid under respective items) at allheightsincludingallleads,lifts,coordination,withthe post- tensioningagency,preparation ofdrawings, obtaining approval from the Employer / Architect etc.Rate to include providing water, power, cement and admixture for grouting, packingofsheathingandanchoragesblockings,fillingof recesspocketsafterstressingusinggrouts(cementslurry mixed with approved admixtures) including providing access to post tensioning at all heights including all leads, lifts etc., all complete and as approvedand asdirected bythe EmployerArchitectbutexcludingshuttering,concreting& reinforcement steel which shall be payable under respective items separately.
49Supplying and installing of not less than 1.5mm composite thick self adhesive HDPE membrane, Dr.fixit Prebond S which is performed HDPE fully bonded membrane that bonds to the wet concrete cast on the membrane, having the following properties.,1.Puncture resistance of 1000N (as per ASTM E 154) 2.Tensile strength of HDPE without Adhesive (Film) of 25Mpa (as per ASTM D 412 Modified),3.Elongation > 500% (as per ASTM D 412 Modified),4.Peel Adhesion to concrete of 880N/m (as per ASTM D 903),5.Dimesional stability of 0.50% (as per ASTM D 1204),6.Hydrostatic head resistance not less than 60m head of water (ASTM D 5385-6), The size of Each membrane sheet on HDPE membrane Should be 2.40X20meter or 3 meter x 20 meter. This system should be fullybonded on thye RCC and consists of higly resillent HDPE film,self adhesive polymer layer and trafficable granular layer.The membrane shall have minimum of 75mm side and end laps which shall be sealed with double sided adhesive tape. All vertical surfaces will be fixed using prefixed gaskets/shot gun etc.,complete as per manufactures specification
50Supply and application of Whitetank© post & pre applied system, integratedwater resistance cell in combination with catalytic effectivehydrophilic mechanism for basement footings, raft & liftpit etc. the product should be conforming higher compressive strength to class R3 & R4 category. Effective transformation of the concrete structure in to barrier irrespective of thickness & no requirement offurther waterproofing system or system protection & to crerate durable concrete structure by extending the service life of the structure being resistance to up to 20 bar hydrostatic water head pressure & permeability reduction more than 97%when compared with control concrete as per DIN 1048 Part 5 and ACI 212-3R-10-16, conforming to the Valenta /Darcy"s formula & self healing up to 0.5mm cracks through out the service life of the concrete by Penetron surface system. The Penetron have the approval from EPD, MORTH, IRC, Greengraud Gold and LEED Platinumfor durabilityfactor with CE approval and supplied from a CE approved manufacturing unit and must be capable of reducing chloride duffcussion coeeficientby more than 45% as comapred to control concrete, when tested as per ASTM C1556. The Whitetank© System should be carried out in 3 different necessary stages including use of Ultrasonic pulse velocity (UPV)
51equiptment to identify & create honeycomb free concrete structurebefore prceeding to post construction treatment as a process of treatment conforming Whitetank© system & manufacturer"s specifications as detailed intechnical specification, complete. Workshall beguaranteedfor10years againstanyleakages & permanent system performance. The joint warranty shall beprovided with manufacturerwith sole responsibility for the performance of the system on Rs.100/-stamp paper inapprovedpreformed. Make:- Penetron India.(The materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard specification).
52Supply & fixing of Hi tensile membarane structure parking canopy with complete fixtures. The fabric thickness will be of 750GSM. The post will be of 200x200 square section. The main truss will be of 80x80 square section. The connecting purlin will be of 80x40 rectangle section. The foundation bolt will be of 2.5" length. Base plate will be of 16mm thick. Bold & Nut system. Yellow zinc oxide primer Asian enamel paint will be coated on the truss section. Self drilling screws will be used as fixtures.
53Fly Ash Brick work in following Cement Mortar using best quality size 230 x 110 x 70 mm for foundation and basement including curing, etc., complete complying with standard specification. In Cement Mortar 1:6 (one cement and six sand)
54In Foundation and basement
55In Ground floor
56In First floor
57In Second floor
58In Third floor
59In Fourth floor
60In Fifth floor
61In Sixth floor
62In Seventh floor
63In Eight floor
64Fly ash brick partition walls of 11.50cm thickness using best qualityin Cement Mortar 1:3 (One Cement and Three P.Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately)
65In Ground floor
66In First floor
67In Second floor
68In Third
69In Fourth floor
70In Fifth floor
71In Sixth floor
72In Seventh floor
73In Eight Floor
74Paving the floor with best approved quality fine polished Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stonesand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification
75Providing Double /Full round nosing for steps including cost of rent of grinding machine, labour etc complete as per the direction of the department officers.
76Cladding the vertical wall surface withpre polished Jet Black granite or similar Varities slab of size 1200x600 of 18 to 20mm thick of approved colour and best quality free from all defects set in cement mortar 1:2 (one cement and two sand) 10mm thick. The joint shall flush with face or granite slab and in line. The joints shall be pointed with same colorpigments mixedwith white cement of 1.8 kg/sq.m. The slabs so laid shall be supported with suitable arrangements for a period of 2 hours after laying to avoid falling granite slabs by its self weight after layingits position. The granite slab shall be got approved by the departmental officers before use on works etc complete. Therate is includinglabour, all material,scaffolding charges, hirechargesfor granite cutting machine, power consumption etc complete
77Paving the floor with best approved quality flamed Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of Steel Grey or Similar varities with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments including nosing etc., The granite stone slabs and other materials to be used shall be got approved by theEngineer concerned before use on work, etc., complete as per standard specification
78Paving the floor with best quality Double Charged Vitrified Tiles of size 800 x 800 x 10mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works)
79Double Charged Vitrified Tiles (800 x 800 x 10mm)
80Flooring with Self design Joint free rectified Ceramic Tiles ofsize 305 x 305 x 8mmlaid over 20mm thick cement mortar 1:3 (Onecement and Tree sand) base mortar over the existing slab / floorincluding cutting the tiles to the required size with special cutterwherever necessary, laying in positionand and pointing with whitecement mixed with colouring pigment at the rate of 0.3 kg. / sq.m.etc., complete complying with standard specification. (The makeand brand of the tiles should be Johnson / Kajaria / Somany / Nitco/ RAK or Equivalent which has to be got approved by executiveEngineer before use on works)
81Self Designed Colour Ceramic Tiles
82Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers.
83Dadooing walls with following best approved quality, white / colour glazed tiles of following sizes set in Cement Mortar 1:2 (One Cement and Two sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers.
84Dadooing with printed design colour glazed tiles of size 300mm x 600mm x 6mm
85Paving the floor with best approved quality fine polished Kota stone slabs of size 600 x 600 of 18 / 20mm with machine cut edges and matching marble slab not less than 100mm width other than Adanga Marbles as border laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and threecrushed stonesand) fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments and polishing with floor polisher to a high degree of finish etc., The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.
86Providing granolithic floor finish of the following thickness with plain cement concrete 1:2:4 (One Cement, Two sand and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panellingwherever necessary and as directed by the departmental officers)
8750 mm thick
88100 mm thick
89Extra for vaccum dewatering in fresh concrete works 80 to 120mm thick by levelling with double framed screed vibrator finishing with power floatter and power trowel and indentical works etc., complete and as directed by the departmental officers.
90Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.
91Paving the Top of roof with Solar refelective ceramic tiles of size 305 x 305 x 7mm thick of approved quality and colour laid in Cement mortar 1:3 (One cement and three crushed stone sand) 12mm thick and pointed with tile grout (Nitotile Grout or equivalent) and cement in the ratio of 1:3 for joint, curing etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by the Executive Engineer before use on works)
92Lime Concrete 1:2:5 (One lime, two sand and five brick jelly ) using 40mm gauge brick jelly for flooring including laying, consolidating, finishing, rendering the top surface rough to receive the floor finish, curing, etc. complete complying with standard specification.(For flooring in toilet portioins except water closet portions)
93Providing and fixing ArchitecturalExpansion joint systemwith twin Aluminum "L" profile of size 50x25mm, sandwiched with neoprine pad over the existing expansion joint in the roof slab/ roof beams, suitably embedded in the tile flooring / Granite flooring seamlessly without any undulation in the flooring. The entire process has to be executed in the following manner. Sealant Installation: Install the single component, polyurethane, flexible sealant, SU 10, in the expansion joints finishing flush with the surface and allow it to dry completely. Then pour the water and cover the expansion joint for at least two days to check whether any leakage occurs in the expansion joint. After completing the process only, the aluminium profile should be fixed. Profile Fixing: Install the Architectural aluminium "L" profile of size 50x25mm with neoprene profile over the expansion joint. The profile must be embedded in the flooring and make sure there will not be any undulations in the flooring. Then Install the polymer-modified mortar over wet binder coat, at all corners in required size.Noted: If the leakage is non-stopping, we have to use Neoprene 1mm thick sheet before applying the sealant. Surface Preparation: All inner surfaces of the expansion joints, including 250mm wide on both sides of the joint shall be cleaned neatly to make it free from all dirt, dust and other contaminants. Loosely bonded particles and weak substrate shall be removed completely.
94Backer Rod Installation: Install polystyrene backer rod in the expansion joint leaving required depth from the top to fill the sealant. The backer rod shall be installed in such a way that, the depth shall be Polyurethane based highly flexible sealant for sealing the expansion joints; thermoplastic elastomeric coated, non-woven, sandwiched between 2 coats of cementitious acrylic modified waterproofing membrane over water-based epoxy polyamide primer equal to the width, if the width of the joint is lesser equal to 10mm, and for a width of the joint above 10mm, the depth shall be maintained half of its width.
95Providing Powder Coated Alumninium Expansion Joint Cover plate (Plain / "L"type) over the expansion joint treatment including cost of labour for fixing with necesasry SS 304L screws, transporation charges etc complete as per the direction of the departmental officers.
96Providing expansion joint in RCC floor slab for 12.5mm width using polysulphide as sealent on the top and bottom for a depth of 7.5mm each and packing the inner space using compressible non-absorbent filler materials including cost of labour for cutting and fixing filler materials and laying polysulphide sealent with necessary spatula etc., complete complying with standard specifications and as directed
97Providing expansion joint 12.5mm width in RCC roof slabs between RCC twin beams using PVC water bar of 150mm wide centre bulb of 4mm to 6mm thickness of approved quality and brand and including filling the inner space with suitable non-absorbent flexible and well compressible filler materials of approved quality and covering the top surface with GI sheet 30cm wide and 1.6mm thick using phill plugs, GI screws, limpet cup washers, bitumen washers, etc., complete complying with standard specifications and as directed
98Providing expansion joint of 12.5mm wide in between RCC twin columns from top of pedastal to full height including filling the inner space with suitable non-absorbent, flexible and well compressible filler materials of approved quality and brand; finishing the sides of RCC columns with polysulphide sealents for a depth of 7.5mm on either side covering the inner space filled with filler materials as above etc., complete complying with standard specifications and as directed.
99Providing and Fixing the 12mm thick Toughened glass door (Saint Gobain/ Equivalent) including cost of patch fittings, floor spring, 450 mm length handle, lock (Dorma / Ozone / Equivalent), cost of handling and transportation etc complete as per the direction of thedepartmental officers.
100Reolving door
101Openable Door (Double side Swing)
102Providing and Fixing the 12mm thick Toughened glass partition (Saint Gobain/ Equivalent) including cost of patch fittings (Dorma / Ozone / Equivalent), clear weather silicon sealent for gaps, cost of handling and transportation etc complete as per the direction of thedepartmental officers.
103Providing and fixing frosted / Patterned sticker (3M or Equivalent make) including cost of labour, consumables, transport etc complete as per the direction of the department officers.
104Manufacturing and spplying of 35mm thick solid core block board flush single/double leaves shutters commercial ply on both sides and Laminate sheet (0.80mm thick) finish on both side hot pressed bonded with liquid phenol formaldehyde resins and external lipping by TW around rebate cutting etc as per IS 2002 part I of 1991 including TW lipping of size 35 x 12 mm including labour charges for fixing all furniture fittings and specials. The flushshutters should be ISI specification and got approved by the Departmental officer before fixing. Brass fittings of 6" tower bolt -1 no, 4" tower bolt - 1 no, door stopper- 1 no, Aldrop - 1 no ,hinges 6 " - 3 nos., ornamental lock and handle,Vision panel - 0.23 x 0.23 with 5.50 mm thick glass with necessary beeding. etc complete as directed.
105Double leaf shutter
106Single leaf shutter
107Supplying and fixing Country Wood frames for doorsWindows and Ventilators using required MS angles, flats and rods of approved design and as directed by the departmental officers including cost of MS Grills, labour charges and cost of one coat of red oxide primer with labour charges for priming coat etc. complete complying with standard specifiction.
108C.W Scantlings UPTO 4M
109Supplying , hold fast of M.S flats of over all size of 330 x 50 x 6mm suitably folded to the required L shape have two end of lap of 50mm long each and overall length of the horizontal portion as 230mm & including making necessary grooves in two end laps to accomadate screws etc., complete.
110Supplying and Fixing of Wood Polymer Composite (WPC) door with solid door frames extruded with size 75mmX50mm. The Inner core made of rigid WPC compound with minimum shore hardness of 55, and Buld Density 750Kg/cub.Mt. The frame shall be fixed to the wall using 10X10mm long MS screw throught the frame by using PVC fasteners. A minimum of 4nos screww to be provided for each vertical members,Door shutter of 25mm thick Wood Polymer Composite (WPC) single core Extruded Door Shutter, with one side digital printing of Specified Design which is approved by engineer-In-Charge. Both side of the shutter shall have rough sugar texture finish, aminated with UV oil.The solid WPC board shall have minimum shore hardness of 55 and Bulk density 550Kg/Cub.Mt moulding the thickness remains 25mm(+/-1mm) etc complete as per the direction of the departmental officers.
111Supply and erection of Double Leaves Fire Rated Door with Frame having the dimension of 1800mm x 700mm with following specifications. A.Door Frame 1.6mm: Galvanized 120 GSM branded make JSW b.Door leaf 1mm: Galvanized 120 GSM branded make JSW c.Shutter Thickness: 46mm d.Honeycomb: In-fill e.Glue Macroplast UR-7221 f.Door Hinges: 4" x 3" x 3mm, Double Ball: Make Assa Abloy Yale Ball bearing Butt Hinges Grade SS304 - Finish SS g.Door Closer with Standard Arm Finish:Silver h.Lock Set: Dead Lock with both side key i.Door Orientation: To be confirmed by client j. Mounting of door: Brick wall mounted k. Powder Coating : Powder coated in standard RAL paint colour of PO Red (60 to 90) Microns l.Single Point Panic Bar (2 Horizontal): Make Assa Abloy Yale or Equivalent m. Dead Lock with both side key: Make Assa Abloy Yale or Equivalent n.Vision Panel 200 x 300mm 2 Hrs. Fire Glass Schott Pyran with Frame 0.Rated Glass Schott Pyran with Frame p.Anchor Bolt with Endcaps The above assembly mounted on concrete or brick wall including the cost of cutting, chipping, concrete packing, plastering, scaffolding all other conveyance as per standard methods and as directed by the Departmental Officers.
112UPVC Ventilator Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profilethe size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles arereinforcedwith GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of2mm.The EPDM rubber (black colour) covered with all over the edges of frame and shutter.The corners and joints should be welded and cleaned.Radiations pin headed glass 4mm thick should be provided in the louvers.The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames.The ventilator should be got approved from the Executive Engineer before use on work
113UPVC Window Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle.The corners and joints should be welded and cleaned.Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong lockingsystems and as per size for arresting noise and energy loss.The connecting mechanism between sash and outer frame that enables opening of the window.The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames.The window should be got approved from the Executive Engineer before use on work
114Supplying and fixing M.S. Grills of approved design for open courtyard, grill, grill work to doors and window opening etc., using necessary mild steel flats for inner and outer members which should be fixed on edges including cutting the members,welding,grinding,one coat of primary coat using best approved quality red oxide primer, dismantling of walls / concrete if necessary, fixing and finishing the dismantled portion to original condition etc., complete complying with standard specifiction.
115Supplying and erecting pull and push type rolling shutter with ISI make of approved size and section using 18 GI sheet.The shutter shall be painted with one coat of red oxide primer and the rate is inclusive of hood covers, transportation charges etc.,
116ROLLING SHUTTERS (WITH ISI MONOGRAM)
117Gear operated type (from 8 m2 to 12 m2 area)
118ROLLING GRILLS (WITH ISI MONOGRAM)
119Gear operated (from 8 m2 to 12 m2 area)
120Manufacturing,supplying and fixing of stainless steel hand rails for main staircase using 50 mm dia 304 L grade stainless steel pipe of 1.60 mm thick at required locations to a height of 900 mm from finished floor level welded to 38 mm dia stainless steel pipe post of 1.00 mm thick as vertical at 900 mm centre with 2 nos of 25 mm dia intermediate horizontal stainless steel pipe of 1.60 mm thick in between.The Vertical pipe has to be welded to the 100 X 100 X 6 mm Ms base plate encased in the base concrete.Thje rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges,etc.,complete.
121Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing.The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade.The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete.
122Supplying & Fixing Hydraulic Door closer of various sizes of approved quality using Aluminium Extruded section body tubular type universal hydraulic door closer with double speed adjustment like HARDWYN (make) "GAZEL" (or) equivalent (with ISI Monogram) etc complete as per the direction of the departmental officers.
123Supplying and fixing of Hilux board false ceiling or equilant using 10mm thick plainboard sheets of approved quality and design. The falde ceiling should be suspended from ceiling using "U" shaped galvanized iron chanels at 1.20m centre to centre on both longitudinal and cross directions.The Gyp board panels are provided as per design/pattern given by the site officer and finishing the ceiling surface with plaster of paris material and including paper tape etc., necessary opening should be made for providing spot lights.Flourescent tubes in the ceiling by covered by using plywood of 12mm thick and the opening should be covered with acrylic panel complying with standard specification and as directed etc., complete and all the materials should be got approved by the Executive Engineer before use on work.The rate is including two coats of plastic emulsion painting over the wall coat primer etc., complete.
124Plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
125Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers
126Plastering with Cement Mortar 1:3 (One Cement and Three Sand) 20mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including finsihing, curing, etc., complete in all floors complying with standard specification and as directed by the departmental officers.
127Providing, mixing, laying polymer based water proofing treatment for the sunken toilet by applying cement based, flexible,water proofing compound confirming to IS:2645,to a thickness of 1mm of the prepared surface of the roof slab/floor slab as per specifications mentioned above providingcement mortar 1:3, water proofing over plaster to a thickness of 12mm over the membrane coating with admixture of approved make. Rateinclusive of preparation of surface,which includes cleaning of surface polymer mortar curing,labour,tools and equipment,etc., Rate inclusive of cement and sand required for the treatement, the cost and labour charges for fixing 25mm dia pressure pipes 15kg/cm2 to a length of 45 cm for drip pipes etc., complete.
128Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a two coats of putty, priming coat including thorough scrapping, sanding of puttying,clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
129Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
130Painting the wall with Texture Finish Paint including labour charges.
131Drilling bore wells anywhere in Tamilnadu including transportation from one place to another within Tamilnadu in alluvial soil sedimentary strata of clay and sandstone shale pebbles boulders etc, by first taking a pilot bore of 140mm / 150mm dia and then enlarging to required dia and then enlarging to required dia direct or reverse rotary mud circulation method using rotary rigs fuel, labour and drilling bentonite and water required for drillng at site etc complete complying with standard specification and as directed by the departmental officers. Upto 60M Depth.
132Reaming 140 / 150 mm dia pilot bore to 300mm dia bore etc complete complying with standard specification and as directed by the departmental officers.Upto 60m depth ending below ground level.
133Supplying of 110mm dia PVC Special blue Casing Pipes 10 kg/ cm2 for bore well of approved quality and best quality confirming to ISS and with ISI mark etc complete complying with standard specification and as directed by the departmental officers.
134Supplying of 110mm dia PVC Special blue Casing Slotted Pipe 10 kg/ cm2 for bore well of approved quality and best quality confirming to ISS and with ISI mark etc complete complying with standard specification and as directed by the departmental officers.
135Labour charges for inserting PVC 150mm dia casing pipes assembly (with slots or without slots) in the drilled holeincluding jointing the pipes with PVC Couplers with cement paste etc. complete, cost including supply and packing the annular space with pebbles of size and quality etc complete complying with standard specification and as directed by the dept officers.
136Charges for developing the bore well with air compressor of 600 CFM capacity (Minimum 8 Hours) including transportation, labour and fuel charges for compressor etc complete complying with standard specification and as directed by the departmental officers.
137Supplying & Laying the HDPE Pipes for Submersible Pump in Bore well Class-5 1 MPa or 10 kg. / cm2 pressure)
13854 mm dia
139Supplying and fixing in position first quality and approved Gun Metal Gate valve /wheel valve /check valve (Heavy Type) with ISI mark of the following sizes including cost of shellac,thread etc., Including labour for cutting and threading of GI Pipe etc.,Complete Complying with standard Specfications for both internal & External Water supply arrangements
14025 mm dia G.M. Gate Valve
14140 mm dia G.M. Gate Valve
14250 mm dia G.M. Gate Valve
143Supplying and fixing in position best variety and approved quality heavy type 15mm dia tap following typeincluding cost for cutting and threading of the galvanised iron pipes cotton thread shellac etc. complete complying with standard specification.
14415mm dia CP Short Long body/ Elbow action tap
14515mm dia CP Health faucet and Bibtap
146Bottle trap
147Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Engineer before use on woks)
148600 x 450 x 5.50 mm mirror
149Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. (The tower rail should be got approved byEngineer before use on works).(Jaquar Model No - AQN - 7711 ) (Make Jaquar / Equivalent)
150600 mm long towel rail
151Supplying and fixing best approved best quality brass CP soap tray of size 150 x 150mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications.(The soap tray should be got approved byEngineer before use on works).
152Supplying UPVC Specials (Schedule 80.) in water supply arrangements (both in internal and external water supply arrangements
153UPVC Elbow
15450 mm dia
15540 mm dia
15625 mm dia
15720 mm dia
15815 mm dia
159UPVC Tee
16050 mm dia
16140 mm dia
16225 mm dia
16320 mm dia
16415 mm dia
165UPVC Reducer
16650 x 40 mm dia
16725 x 20 mm dia
16820 x 15 mm dia
169UPVC Reducer Elbow
17050 x 40 mm dia
17125 x 20 mm dia
17220 x 15 mm dia
173UPVC Reducer Tee
17450 x 40 mm dia
17525 x 20 mm dia
17620 x 15 mm dia
177UPVC Hex Nipple
17825mm dia
179Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia "B" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works).
180White Glazed without pedestal
181Supplying and fixing in position by means of 75 mm long and 65 mm dia counter sunk bolt and nuts embedded in the floor with rubber or fibre washer white glazed European Water Closet with 100 mm "P" or "S" trap with double flapped rigid PVC black seat and seat cover with C.P. brass hinges including supply and fixing 10 litres capacity PVC low level flushing tank with a pair of C.I. brackets, etc., complete with all fittings such as 15 mm brass ball valve with polythene float with brass handle, union coupling connected by means of 40 mm white PVC flush hand using Indian adopter joint including all internal fittings such as 15 mm brass connections, 15 mm G.M. wheel valve, 15 mm brass nipple (2 Nos.), 15 mm nylon connection and fixing the low level ISI marked flushing tank with T.W. plugs and screws and giving necessary connection to the PVC pipe includingcost of 600 mm length of 110 mm dia PVC Pipe and painting the Cost Iron Bracket with 2 coats of approved synthetic enamel paint over one coat of red oxide primer and redoing the dismantled masonry to slab original condition etc. complete complying with standard specification.
182European water closet with "P" or "S" Trap with Double falpped seat and seat cover with Brass Hinges and 12.5 litre capacity porcelin low level flushing tank with all internal fittings
183Supplying and fixing in positionurinal flat back, back inlet white glazed earthern wareof best approved quality with G.I. Pipe connection of suitable length, 32mm bell mouthed PVC connection, concealed stop valve 5089 and fixing the urinal to the wall in position with necessary T.W.plugs, clamps, screws, shellac etc., including dismantling masonry if necessary and redoing the same to original conditionand checked without any lealage complete complying with standard specifications.The Urinal should be got approved from the Executive Engineer.
184White glazed earthernwere lipped mouth flat back urinal
185Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works)
186Nahani Trap of size 100 x 75mm with stainless steel gratings
187Supplying and fixing in position 150 x 100mm "P" or "S" stoneware gully trap "A" grade with CI double gratings of size 150 x 150mm and 230 x 230mm at bottom and top respectively with necessary earth work excavation laid over a bed of brick jelly cement concrete 1:3:6 (One cement, Three sand and Six broken brick jelly) 150mm thick using 40mm size broken brick jelly including necessary brick work and plastering including dismantling masonry wherever necessary and re-doing the damaged portions to the original conditions using cement concrete 1:3:6 using 20mm stone jelly for fixing the gully trap and giving connections to stoneware sewer line etc., complete complying with standard specifications. [Earth work excavation, brick work, plastering shall be measured and paid separately]. The stoneware gully trap should be got approved by the Executive Engineer before use on works.
188Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level
18975mm dia PVC soil / waste pipe
190110mm dia PVC soil / waste pipe
191160mm dia PVC soil / waste pipe
192Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works).
193PVC Elbow
194160mm dia
195110mm dia
19675mm dia
197PVC Elbow with Door
198110mm dia
19975mm dia
200PVC Tee
201110mm dia
20275mm dia
203PVC Tee with Single Door
204110mm dia
20575mm dia
206PVC Y
207110mm dia
20875mm dia
209Supplying and fixing in position PVC cowls of following dia of best approved quality conforming to BIS, etc., complete complying with standard specifications.(The PVC cowl should be got approved by the Executive Engineer before use on works).
210PVC Cowl
211110mm dia
21275mm dia
213Supplying, laying and jointing UPVC Pipe (Un-Plasticized Polyvinyl Chloride) (Schedule-80) of approved quality and best variety conforming to BIS of the following dia including cutting, and fixing UPVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications.The UPVC Pipe (Un-Plasticized Polyvinyl Chloride)shall be got approved by Executive Engineer before use on works. Internal Water Supply Arrangements using UPVC pipes
21420 mm dia PVC Pipe
21525 mm dia PVC Pipe
216Supplying, laying and jointing UPVC Pipe (Un-Plasticized Polyvinyl Chloride) (Schedule-80) of approved quality and best variety conforming to BIS of the following dia including cutting, and fixing UPVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications.The UPVC Pipe (Un-Plasticized Polyvinyl Chloride)shall be got approved by Executive Engineer before use on works. External Water Supply Arrangements using UPVC pipesAbove Ground level
21732 mm dia PVC Pipe
21840 mm dia PVC Pipe
21950 mm dia PVC Pipe
220Construction of Inspection chamber or manhole of the following size including necessary earth work excavation in all soils to full depth as may be directed with sand filling at bottom of the chamber for 10cm thick, concreting CC 1:5:10 using 40 mm guage HBGs jelly 10 cm thick and sode walls 9" thick brick work in cement mortar 1:5 using II class chamber burnt bricks of size 9" x 43/8" x 23/4" filling the size of foundation with excavated earth, plastering with cm 1:3 20m thick for inside and bottom and making necessary benching with brick jelly cement concrete to the required slope and fifnishing neatly etc., complete.
221Inspection Chamber of Size 0.60 x 0.60 x 0.60m
222Inspection Chamber of Size 0.75 x 0.75 x 0.90m
223Inspection Chamber of Size 0.75 x 0.75 x 1.2m
224Supplying and fixing in position SFRC of various sizeof best approved quality as per standard specification etc., complete compying with standard specifications
225600 x 600 mm
226750 x 750 mm
227Supplying and fixing in position best approved of ISI quality of 160mm dia PVC rain water down fall pipes having a working pressure of 4kg/sq.cm including cost of necessary PVC shoe, PVC bend, C.I gratings of required diameter and special clamps, brass screws, nails, etc. and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc, complete.The rate shall be inclusive of cost removable iron grating.The PVC pipe shall be fixed in wall with special type of clamps. special type of "U" clamp at the centre of the pipeline shall be fixed in addition to those for more than 3.0 M pipe length complying with standard specification.
228Supply and delivery of clear water vertical wet type submersible pump (5HP) suitable for 100mm / 150 mm dia borewell conforming to IS 8034/2002 as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continuos rated two pole suitable wet type vertical squirrel cage induction motor as per IS 9283 /1995 and as amended there after, suitable for operation in AC three phase 415 V+/- 10 %, 50 HZ +/- 5 %
229Supply and delivery of Open well Submersible pump set conforming to IS 14220 /2002 and as amended thereafter and BEE 3 Star Rated capable of discharging the following duties due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze mixed type impeller, CI FG 200 grade casing and brass screws and rotor shall be of copper rod as per IS 613/1984 with ISI mark. The pump suitable for installation in sump with 1.1KV grade 3 core suitable copper flat submersible cable to a length of 15m with necessary cable joints. The non-return valve located at the top of the pump in the discharge outlet connection is to be designed with minimum friction. The pump should be directly coupled to 2880 RPM, three phase, 50 Hz (±5), 415V+6% & 415V-15% squirrel cage induction motor suitable for DOL upto 5 HP , Fully Automatic Air break Star Delta up to 20 HP and Auto Transformer starter for above 20 HP starting and for continuous operation.
230Supply and fixing 3 phase panel for the motor pump set including cost of labour, dry run protection and Timer facility etc complete as per the direction of the departmental officers.
231Supplying and fixing of 18 to 20 mm thick white marble partition slab for urinals of 1200x600(Avg) mm size fixing to wall using3Nos. of suitable chromiumplated brackets with CP bolt and nets, washers, cutting to required shape polishing to all the expose and surfaces and edge grinding etc; complete as directed by the dept officers.
232Supplying & Laying Rubber moulded hydraulic pressedplain / Color cement concretepaver blockusing in cement concrete 1:1 1/2:3 (One Cement one and half sand and three granite chips) of size of 6mm to 10 mm etc., complete and as directed by the departmental officers. The rate is inclusive of labour charges for laying,compacting using earthrammers, conveyance charges etc complete as direction of the departmental officers.
23363 mm thick
23480 mm thick
235Construction ofgranular sub base by providing close graded material,mixing in a mechnical mix plant at OMC, carriage of mixed material to work site,spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller toachieve the desired density,complete as per clause 40.(Grade V)
236Providing and laying,spreading and compacting graded stone aggregate to Wet Mix Macadam 250mm thick specification including premixing the material with water at OMC in mechnical mix plant carriage of mixed material by tipper to site laying in uniform layers with paver in Sub base/ Base course on well prepared surface and compacting with vibratory oller to acheive the desired density including cost of material, labour charges,rentals for machinery,fuel and all other incidentials charges etc., complete as per clause 406 of MORTH Rev-5.
237Supplying and erecting in position of following liters capacity Industrial Model Reverse Osmosis Water-cum-Purifier to deliver Potable Water with World Health Organisation (WHO) Standards with following accessories. (a) MS Skid - 1 No. (b) Media 11054 No. Vessel with 20 nb Multiport Valve (with Media Pubble and Fine Sand and Activated Carbon Filling) set (c) Feed Pump 0.50 HP – 1 No. (d) Vertical Pump 2-9, 2.00 HP / Single Phase – 1 No. (e) Membrane 40 x 40 filmtech (or) equilaents / Osmonic (USA) - 1 No. and Membrane Pressure Vessel 40 x 40 -1 No. & Pressure Gauge - 2 Nos. (f) Flow Meter - 1 No. 20” Filter with Housing - 1 No.Low Pressure Switch - 1 No., Level Switch - 1 No. & Necessary CPVC Pipes and Fittings. The system shall be provide with Two Panel Control System with necessary Stainless Valves and Fittings and Float Control etc.The rate should be inclusive of all civil works, wherever necessary to install the System in position and intact
238RO 1000 Litres
239Water Dispenser
240Labour charges for Dewatering the water using 10 HP Capacitydiesel engine pumpset with necessary raw materials such as supply of suction hose, Delivery hose up to 100 feet distance, Supply of Diesel, Supply of Engine Oils, Labour charges for operating the Engine and Helper (Day and night Hours) for dewatering the water from low level and building inner portion to outer main drains etc., The rate is inclusive of Hire charges for Disel engine, Cost of fuel, Cost of engine oil. Labour charges, Hire charges for connection additional hose, Conveyance charges for loading and unloading etc., Complete as directed by the departmental officers.
241Design, Supply, Erection and Commissioning of 120 KLD Packaged STP with MBR Technology.A) Coarse Bar Screen- Supplying ,installing, testing and commissioning of MSEP screen with spacing 10 mm and 5 mm thickness including cost of material , labour,complete. (Make: HECS/ Equivalent)B) Raw Sewage Transfer Pump -2 Nos (1W+1S)- Collection sump Supplying , installing , testing and commissiong of Raw Sewage transfer pumps - Collection Tank.The pump is horizontal centrifugal type,capacity of 5 cum/hr @head 12 m & as per site condition, consistes of pipes and fittings, MOC of pump is CI including cost of material ,labour, HOM etc.,complete., Make : Kirloskar/CRI.C) Oil Skimmer-Supplying ,installing, testing and commissioning of Oil Skimmer of Belt in Teflon/ PU 100 mm W x 1000 mm L & Structure in MS Epoxy and Oil Collection Tank of Cylindrical Vertical type, Capacity of 200 lts & MOC HDPE including cost of material , labour, etc complete. Make : HECSD)Rotary Drum Screen- Supplying ,installing, testing and commissioning of Drum Screen of Rotary type with Capacity 5 cum/hr, Pore size < 1 mm , MOC : SSincluding cost of material , labour, etc, complete. (Make : HECS / Equivalent)
242E) 120 KLD HECS Amaze MBR based Packaged Sewage treatment Plant (STP Plant)-Designing, supplying , installing , testing and commissiong of 120 KLD HECS Amaze Packaged sewage treatment plant with IOT based monitoring system using Android and IOS mobile app - MOC of FRP and thickness 12 to 14 mm. Vessels consists of Anoxic tank, Aeration Tank, MBR Tank and Treated water tank. It includes MBR Membrane and skid of Hollow Fibre immersed type with 7 minutes operation and 1 minutes relaxation and Dry Storage condition, Flux rate: 25 LMH, Membrane material: Reinforced PVDF (including support layer), Support pipe: SUS 316L, (Make: Mitsubishi / Equivalent) Anoxic tank agitator - MOC: SS 304, Air blower for Aeration tank and MBR membrane - Twin lobe rotary with operating pressure of 0.5 ksc - MOC: CI, Diffuser for Aeration tank and collection tank - Standard UPVC type, MBR Permeate pump - centrifugal type of 5 cum/hr capacity - MOC: CI,RAS Pump of centrifugal Nonclog type - MOC:CI, CIP Pump of centrifugal monobloc pump of 3 cum/hr capacity - MOC: SS 316, CIP Tank of capacity 500 L with MOC of HDPE/LDPE, Micron cartridge filter - MOC: PP, Hypo dosing pump at MBR permeate tank - 0-6 lph Electronic Metering Pump with MOC of PP, Hypo dosing tank with MOC of HDPE.(Make: HECS /Equivalent)
243F) Sludge Bag System -Supplying and installing of sludgebag system with MOC of SKID: MS, Internal water contact part:FRP Coating / Glass flake paint and All nonwater contact part:Epoxy paint - (Make: HECS /Equivalent)G)Interconnecting Pipes & Valves -Supplying and laying of pipes and fittings, MOC of Sewage & Water Pipeline is UPVC and MOC of Air Pipelines is GI and ball Valves , Butterfly valves & Non Return valves of MOC CI including cost of material,labour,HOM etc.,complete.,raw sewage inlet upto plant battery limit and treated water outlet plant battery limit piping is Stanley Hospital scope, UPVC Pipeline Make:Supreme/Astral/Finolex ,GI Pipe Make: Jindal/Tata, Make of Ball Valves : ISI ,Make of Butterfly Valves: Intervalve/L&T/Cair ,Make of NRV: Intervalve/L&T/Cair H) INSTRUMENTS -Supplying, installing, testing and commissioning of instruments like Flow Meter for Permeate, RAS, Aeration air, Membrane Air, Level Sensor for Aeration tank & Membrane tank, Pressure gauges , DO & pH sensor, Solenoid Valve including cost of material, labour etc.,complete.,Make of Flowmeters : Make: Aster/Forbes Marshall / Equivalent
244I) Electrical Panel & Accessories -Supplying and laying of electrical cable tray with all cables and accessories & PLC Controlled operation along with necessary earthing and wires, gland termination and accessories.Make of Cables: Finolex/ Orbit/ Polycab/Equivalent
245Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points /Coil)
246Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points /Coil)
247Wiring with 3 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A two way module switch with module front plate with connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour for Concealed PVC pipe Stair case Light point
248Supply and fixing of one no6A two module 5 pin socket with 1 no.6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher end.
249Supply and fixing of 2 nos.6/16A two module socket , 2 nos. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections.Higher end.
250Supply and fixing of 3nos.6A two module 5 pin socket , 3 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higer end.
251Supply and fixing of 20w Recesses/surface LED round typemounting 200mm x52mm of LUKERs cat no.LOR65-20 LED Surface ceiling Fitting complete with PVC unsheathed copper leads from terminals to the Fittings. (LUKER/ Equ make)
252Supply and fixing of 20W, 4 feet LED fitting on wall or ceiling with PVC unsheathed copper leads from terminals to the fitting
253Supply and fixing of 1" X 1" Indoor Commercial LED Luminaires Model - PLUTO PANEL (SURFACE), Item Description - PLUTO1 X1PLS18W LED857S, HSN Code - 9405, Make - HAVELLS from ceiling with PVC unsheathed Copper leads from terminals to the fitting with tubes
254Supply and fixing of 2 x 2 - 45W LED surface mounting luminaire(Like1" x 1" Indoor Commercial LED Luminaires, Model - LUKER Make cat no.LKMSRS45 595mmx595mmx35mm ) fixingon ceiling complete with PVC unsheathed copper leads from terminal to the fitting
255Supply and fixing of WT Bulk head fitting with guard (Philips/ bajaj/ Crompton/k- lite) suitable for 9W LED lamp with LED Bulb.
256Supply and fixing of 30W LED Striplight High wattage Marathon Ultra 120LED(CDL)LED Rope lightfittingcat no.Model No.582161(Warm White)with Drive fixing on the existing Name board all roundbeeding Gate No-1 with complete connection etc.
257Supply and fixing of 1200mm (48") sweep AC ceiling fan complete(Hgher End) with 2 module 100W fan step regulatorwith 300mm down rod on the existing fan clamp
258Supply and fixing of 300mm (12") sweep (light duty) AC exhaust fan complete with necessary wall opening and making good of the wall
259supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting
260Supply and fixing of UNECO Track LED light complete channel of size 2 mtrs with 5 nos of 25Watts LED Fitting warm white/ Normal white complete connection etc.,
261Supply and fixing of 6 way Vertical Triple pole and neutral MCCB sheet steel enclosure distribution board (with MCCB Incomer ) with double door (metal door) with 1 no. 100 A 3 P MCCB with 63A 30 ma ELCB as incoming and 2 nos. 63A 3P MCB, 1nos 32A TP MCB and 9 nos 6A-32A SP MCB as outgoing with suitable cable end box in flush with wall with earth connection only.
262Supply and fixing of 4 Pole in sheet steel enclosure with accommodate for the S&F of 1 no4Way Din rail with Four pole 63A MCBcomplete fixingin flush with wall with earth connection.
263Supply and run of 2 of 2.5 sq.mm. (36 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 2.5 sqmm copper wire and making good of the concealed portion with suitable colour. (3 Nos 5A Plug )
264Supply and run of 2 of 4 sq.mm. (56 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 2.5 sqmm cu. wire and making good of the concealed portion with suitable colour. (15A Plug )
265Supply and run of 4 of 6 sqmm (84/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 2.5 sqmm cu. wire with painting of suitable colour.(32A 4P Enclosure)
266Supply and run of 4 of 10 sqmm (101/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 4 sqmm insulated SC unshethed copper wire with painting of suitable colour.(63 4P MCB)
267Supply and run of 4 of 16 sq.mm. (101/0.45) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire with painting of suitable colour. (6way vertical MCCB DB"s)
268Supply and installation of GI perforated cable tray with cover of te followingsizes 450 mm width x Depth 50 mm thickness 12 SWG fromand 300mm x50mm the wall / ceiling. The cable tray shall be fabricated in standard length of 2.5 meterof size with suitable supporting arrangements shall be provided at equal intervals with suitable angle/ channel from the wall / ceiling while erecting the cable tray. Jointing of cable trays shall be GI Coupler plates to match the dimension of the cable tray. Fixing both for the jointing of the tray and fixing of the trays on the structure shall be with Thread Rod or approved type of corrosion resistant fixtures. Where necessary, GI bends, tees, reducers, cross members, clamps, hot dipped galvanized iron angle of suitable size, anchor bolts, steel bolts etc., shall be provided by the contractor. GI cable trays shall be heavy dutymaterial shall be both acid resistant as well as corrosion resistant to saline atmosphere. Trays laid in Horizontal/ vertical configuration should be provided with flat rungs with spacing of 300 mm and side rails of sufficient strength to ensure
269no damage during the stipulated life. The cables placed in Horizontal/ vertical trays shall be held in position by using proper type of clamp arrangement so that the same do not rest on the side rails during laying or service life.. The side runner will also have suitable holes at every meter for cleating earthing strip. Suitable tapped holes shall be provided on the runner top and bottom for supporting and fixing tray covers at every meter.
270450mm x 50mm
271300mm x50mm
272Supply and clamping of2 Runs 3-1/2 x 185 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps (For 2 Nos 400A 3 Phase Metering panel incoming)
273Supply and fixing of brass cable gland for 3-1/2 x 185 sq.mm. PVC armoured LTUG cable with earth connection
274Supply and providing cable end termination of 3-1/2 x 185 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete
275Supply and clamping of 2 Runs 3-1/2 x 300 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps(For 5 Nos 630A 3 Phase Metering panel incoming)
276Supply and fixing of brass cable gland for 3-1/2 x 300 sq.mm. PVC armoured LTUG cable with earth connection
277Supply and providing cable end termination of 3-1/2 x 300 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete
278Supply and clamping of 3-1/2 x 50 sq.mm. PVC LTUG armoured cable on post / Existing tray or on wall with MS clamps (For 100A MCCB DB)
279Supply and fixing of brass cable gland for 3-1/2 x 50 sq.mm. PVC armoured LTUG cable with earth connection
280Supply and providing cable end termination of 3-1/2 x 50 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete
281Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with Module GI switch box on wall with 6A one way module switch with module front plate with painting of Suitable colour with continuous earth wire connection of 14 SWG TC wire for Open MS conduit Light point / fan point (for electronic regulator) 5 points / Coil) Higher End(For 4 Nos Lift well) (Make:Crabtree/ Legrand/ Hager/ equivalent)
282Wiring with 2 x 1.5 sq.mm. (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with 150mm x 100mm x 75mm MS switch box inflush with wall with 3mm thick hylum sheet cover for 5A 3pin non interlocking flush type CS plug with painting of suitable colour with continuous earthwire connection of 14SWG TC wire for open plug point (For 4 Nos Lift Well) (Make:Crabtree/Legrand/ Hager/ equivalent)
283Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch on sutable module surface mounting (GI) with module cover plate (plastic) onwall with connections.Higher end.
284Supply and fixing of 4 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCB switch as incoming and 12 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. The MCB DB and MCB’s should be with ISI mark. (Hager/legrand)
285Supply and fixing of 2 pole enclosure with accommodate for the S&F of 1 no2Way Din rail with Double pole 32A MCBcomplete fixing on the wallwith earth connection.(For shaft well lighting control)
286Supply and clamping of 3½ x 35sqm sq.mm PVC armoured LTUG cable on wall with MS clamps
287Supply and providing cable end termination of 3-1/2 x 35 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete
288Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection.
289RMG:- Supply, Erection, testing and commissioning of 11KV 25 KA 630Amps 3 Panel HT Indoor/Outdoor RING MAIN GEAR(RMG) Switch board suitable for Indoor/ Outdoor installation comprising two incomer Load break switches panels and one outgoing 11 kv HT Vacuum Circuit Breaker complete as per TANGEDCO specification with Mechanical inter lock between incomers. 1.Supply and Erection of Draw out type 11KV 25KA 800Amps Horizontal draw out / Horizontal Isolation VACCUM CIRCUIT BREAKER filled with motor(230V AC) operated spring charged Mechanism, with ON and OFF mechanicalIndicator Anti Pumping Device, 110V DC Shunt Trip and Closing Coils (DC source of supply to be derived from a power pack suitable for three Tripping and two closing operations incorporated on Incoming panel only) Mechanical Operation counter, 4NO + NC Spare Aux. Contact with contact multiplication Contactor for customer use. Automatic safety shutter, Mechanical close/Trip Knob, Mechanical ON/OFF Indication, Operating Handle, 230V AC to 110V DC Power pack operating Handle etc.-1No 2. Supply and erection of 11KV 630Amps 25KA HT Air Break/Load Break Switch with mechanically inter locked earth switch, front operated spring
290assisted manual closing mechanism , 2 NO+ 2NC Aux. Contact operating handle etc.-1No 3. 11KV/Root 3/110V/Root3-Three Phase 3 Limb 50VA class0.5 Resin cast Draw out type potential Transformer complete with HT and LT HRC fuses with sealing arrangement-3 Nos. 4. Current Transformer of Suitable Ratio XXX /5-5A dual Core (Core 1-5VA Class 0.5 for Metering & Core 15 VA 5P 20 for Protection - 3 Nos5. Meters: Analog ammeter with 5 position selector switch -1 No Analog Voltmeter with selector switch-1 No cut out provision to receive digital Trivector Meter L&T or secure tobe provided. 6. Protection: MCDG 61 TP ND IDMT two over current and one earth fault Relay with higher set Instt. Elements 1.3 Seconds-1 No Master Trip relay Mega win MVAJH 13eqivalent-1 No
2917.Breaker On/Off indication LED Type-2 No Auto Trip/ Healthy Trip and spring charges indication LED type-3 Nos phase indicating Lamps RYB - 3Nos 8.TNC Breaker Control Switch -1 No local Remote selectorswitch- 1 No Push button for trip Healthy- 1 No9. Necessary Control wiring with Copper wire 10. 630Amps Copper Bus bar PVC sleeved & required panel Earthing.11. Common for Switch gear MCB"s for AC/DC Control Heater ON/OFF switch with space Heater and thermostat, single phases switch socket, cubicle illumination TL lamp, Door switch fullycovered Test Terminal block of IMP make (wherever applicable) 12.MS Sheet steel Enclosure for outdoor Installations powdercoated with siemens Grey paint finish 13. Provision through bottom entry to receive Incomer &Out going cable excluding cable glands and cable Termination Kit (Make:Megawin / VMC / ABB /or Equivalent
292Three Panel HT VCB:-Design, manufacturing supply, erection, testing, commissioning and handling over of 11KV 25 KA HT Five panel Vacuum Circuit Breaker Switch Board Comprising one number 800A 500MVA VCB as incoming and 2Nos. 630A 500MVA VCB as outgoing panels for Indoor /Outdoor installation each panel comprising.1) Draw out type 11KV 500MVA 630A Horizontal Draw out/ Horizontal Isolation Vacuum Circuit Breaker operated withSpring charged mechanism.Anti Pumping Device,110V DC shunt Trip and closing Coils (DC source of supply to be derived from a Power Pack suitable for 3 Tripping and Two closing operation counter, 3 NO + 4NC spare Aux. contact for customer use, Automatic safety shutter, Mechanical Close / Trip knob, Mechanical ON/OFF indication, Operating Handle, 110V AC - 110V DC Power Pack etc. (Incoming 1 No. Outgoing 4Nos.) 2) 11KV /Root 3/110V/Root 3 - Three Phase, 3 Limb 200V A Class 1 Resin Cast
293Draw Out type Potential transformers complete with HT and LT HRC fuses.(Incoming - 1 No.) 3) Current Transformers of 100 - 50/5-5 Amps. Dual Core (Core 1 - 15 VA class 1 for metering and core 2 - 15 VA 5P 10 for Protection) Incoming 3 Nos, Current Transformers of 50/5-5 Amps Dual Core (Core 1-15VA Class 1 for Metering and Core 2 - 15VA 5P 10 for Protection) (Outgoing 2 Nos)4) Meters:Digital Ammeter with Selector Switch (Incoming 1 No. Outgoing 1No Digital Voltmeter with Selector Switch (Incoming 1 No.)Digital Trivector of L&T / Securemake (Incoming 1 No.)Digital power Factor meter (Incoming 1 No.) Digital Frequency Meter (Incoming 1 No) 5) Protection:
294TP ND IDMT 2 OC + 1 EF R with Highest inst. Elements similar like Megawin type MCDG 61(Incoming1no) 6) TP ND IDMT 2 OC + 1 EF Relay similar like Megawin type MCDG31 Master trip Replay Megawin MVAJH 13 (Incoming 1No. Outgoing 1 No7)Breaker ON/OFF/AutoTrip/Healthy Trip/Spring charged Indication lamp LED type(Incoming 5 Nos. Outgoing 5 Nos.)8) Phase Indicating Lamps R,Y and B (Incoming 3 Nos) 9) Control Wiring.10) 800Amps copperBus BarPVC sleeved and required panel copper Earthing.11) Control Switch TNC (Incoming 1 No. Outgoing 1 No.) 12) Trip Circuit Healthy Push Button(Incoming 1 No. Outgoing 1 No.)13) Common for Switch gear, MCB"s for AC DC Control, Heater ON/OFF Switch with spaceHeater and thermostat single phase switch socket, cubicle illumination lamp, Disconnecting type terminal Block etc.14) MS sheet enclosure for IndoorInstallation Powder Coated withpaintshade siemens Grey, paint finish Provision through Bottom entry to receive Incoming and Out going cable excluding cable glands and cable terminationkit.(Make : system control / Megawin/ Voltech/ ABB/or Equivalent
295Four Panel HT VCB:-Design, manufacturing supply, erection, testing, commissioning and handling over of 11KV 25 KA HT Four panel Vacuum Circuit Breaker Switch Board Comprising one number 800A 500MVA VCB as incoming and 3Nos. 630A 500MVA VCB as outgoing panels for Indoor /Outdoor installation each panel comprising.1) Draw out type 11KV 500MVA 630A Horizontal Draw out/ Horizontal Isolation Vacuum Circuit Breaker operated withSpring charged mechanism.Anti Pumping Device,110V DC shunt Trip and closing Coils (DC source of supply to be derived from a Power Pack suitable for 3 Tripping and Two closing operation counter, 4 NO + 4NC spare Aux. contact for customer use, Automatic safety shutter, Mechanical Close / Trip knob, Mechanical ON/OFF indication, Operating Handle, 110V AC - 110V DC Power Pack etc. (Incoming 1 No. Outgoing 3Nos.) 2) 11KV /Root 3/110V/Root 3 - Three Phase, 3 Limb 200V A Class 1 Resin Cast
296Draw Out type Potential transformers complete with HT and LT HRC fuses.(Incoming - 1 No.) 3) Current Transformers of 200 - 150/5-5 Amps. Dual Core (Core 1 - 15 VA class 1 for metering and core 2 - 15 VA 5P 10 for Protection) Outgoing 3 Nos, Current Transformers of 80/5-5 Amps Dual Core (Core 1-15VA Class 1 for Metering and Core 2 - 15VA 5P 10 for Protection) (Outgoing 2 Nos)4) Meters:Digital Ammeter with Selector Switch (Incoming 1 No. Outgoing 1No Digital Voltmeter with Selector Switch (Incoming 1 No.)Digital Trivector of L&T / Securemake (Incoming 1 No.)Digital power Factor meter (Incoming 1 No.) Digital Frequency Meter (Incoming 1 No) 5) Protection:
297TP ND IDMT 2 OC + 1 EF R with Highest inst. Elements similar like Megawin type MCDG 61(Incoming1no) 6) TP ND IDMT 2 OC + 1 EF Relay similar like Megawin type MCDG31 Master trip Replay Megawin MVAJH 13 (Incoming 1No.Outgoing 1 No7)Breaker ON/OFF/AutoTrip/Healthy Trip/Spring charged Indication lamp LED type(Incoming 5 Nos. Outgoing 5 Nos/Each.)8) Phase Indicating Lamps R,Y and B (Incoming 3 Nos) 9) Control Wiring.10) 800Amps copperBus BarPVC sleeved and required panel copper Earthing.11) Control Switch TNC (Incoming 1 No. Outgoing 1 No.) 12) Trip Circuit Healthy Push Button(Incoming 1 No. Outgoing 1 No.)13) Common for Switch gear, MCB"s for AC DC Control, Heater ON/OFF Switch with spaceHeater and thermostat single phase switch socket, cubicle illumination lamp, Disconnecting type terminal Block etc.14) MS sheet enclosure for IndoorInstallation Powder Coated withpaintshade siemens Grey, paint finish Provision through Bottom entry to receive Incoming and Out going cable excluding cable glands and cable terminationkit.(Make : system control / Megawin/ Voltech/ ABB/or Equivalent
298Supply, Erection, Testing and Commissioning of 1000 KVA,11KV/0.433V Dyn11,ONAN, Indoor /Outdoor Type, double wound, Energy Efficient Transformer with OFF Circuit type. distribution transformer confirming to relevant IS.1180 Level-1and fitted with the following. 1.Rating &connection diagram plate 2.Earthing terminal 3.Lifting lugs for whole Transformer 4.Cover lifting lugs 5.Oil level gauge-plain with level marking 6.Bottom filter cum drain valve with plug 7.Top filter valve with plug 8. pocket for Thermometer 9.Oil Conservator with drain plug 10.Oil filling point with cap on the conservator 11.Air release plug 12.Silicagel breather 13.Monogram plate 14.Explosion vent with diaphragm 15.Transformer oil 16.Under base channel with skids 17.Oil temperature indicator with A/T Contacts 18.Winding temperature indicator with A/T Contacts
29919.Marshaling box 20.Bi-directional rollers. 21.Buchholz relay with A/T Contacts 22.DetachableRadiators. 23.Off circuit tap switch 24.Conservator shut off valve 25. Neutral CT Special accessories The transformer should be supplied with first filling of oil Terminal arrangement:- HV- Cable box,LV-Flange to suit bus duct. All removable covers shall be provided with weather proof hot oil resistant, resistance gaskets, to prevent leakage of water in to core, and oil from the tank with Transformer plinth construction of 1000KVA as per IS 1180 (Make ROWSON / Voltech/ IPL or Equivalent)
300Supply, Erection, Testing and Commissioning of 1600 KVA,11KV/0.433V Dyn11,ONAN, Indoor/Outdoor Type, double wound, Energy Efficient Transformer with OFF Circuit type. distribution transformer confirming to relevant IS.1180 Level-1 and fitted with the following. 1.Rating &connection diagram plate 2.Earthing terminal3.Lifting lugs for whole Transformer 4.Cover lifting lugs5.Oil level gauge-plain with level marking 6.Bottom filter cum drain valve with plug 7.Top filter valve with plug8. pocket for Thermometer 9.Oil Conservator with drain plug 10.Oil filling point with cap on the conservator 11.Air release plug 12.Silicagel breather 13.Monogram plate 14.Explosion vent with diaphragm15.Transformer oil16.Under base channel with skids 17.Oil temperature indicator with A/T Contacts18.Winding temperature indicator with A/T Contacts 19.Marshaling box20.Bi-directional rollers. 21.Buchholz relay with A/T Contacts22.DetachableRadiators.
30123.Off circuit tap switch 24.Conservator shut off valve 25. Neutral CTSpecial accessoriesThe transformer should be supplied with first filling of oil Terminal arrangement:- HV-Cable box, LV-Flange to suit bus duct. All removable covers shall be provided with weather proof hot oil resistant, resistance gaskets, to prevent leakage of water in to core, and oil from the tank with Transformer plinth construction of 1600KVA as per IS 1180 (Make ROWSON / Voltech/ IPL or Equivalent)
302Supply and clamping at 11 KV 3 core 300 sq.mm XLPE HTUG cablein existing trench / pipe laid in ground. (From RMG-1 to 5Panel HT VCB & RMG-2 to 4Panel HT VCB,Four Panel HT VCB to 1600 KVA Transformer 1 &2, )
303Supply and clamping at 11 KV 3 core 240 sq.mm XLPE HTUG cablein existing trench / pipe laid in ground. (From 5Panel HT VCB to 1000 KVA Transformer 1 &2,and Existing 630 KVA Transformer ,)
304Supply and providing cable end termination suitable for 11KV 3 core 300 sq.mm XLPE HTUG cable with necessary indoor type heat / cold shinkable joint kit and accessories. (Make:RayChem / M.Seal.(at RMG-1=3Nos, 5 Panel HT VCB Panel-1 No, RMG-2=3Nos,4 panel HT VCB -3nos, 1600A Tr 1&2=2nos)
305Supply and providing cable end termination suitable for 11KV 3 core 240 sq.mm XLPE HTUG cable with necessary indoor type heat / cold shinkable joint kit and accessories. (Make:RayChem / M.Seal. (at 5 Panel HT VCB Panel-3 Nos, 1000 KVA Transformer 1 & 2 -1 no Each and 630 KVA Existing Transformer-1 No)
306Design, Supply, erection, testing and commissioning of 1600A aluminium Bus Ducts made up of 16 SWG sheet steel minimum thickness of 1.8 mm bolted on to an angle iron / structural steel framework.covers the requirements of 3 phase 415 V, 50 Hz, 1600A continuous rated, copper TPN bus with enclosure suitable for Indoor/Outdoor type.The bus – duct shall be designed for the above current ratings and for a maximum temperature rise of 400C over an ambient temperature of 45°C. The bus – bars shall be of hard drawn high conductivity electrolytic grade aluminium flats of size 2Runs x 100mm x12mmelectrical grade 63401-WP as per IS: 5082 The bus- bars shall be of uniform cross section along its entire length. No tapering of the bus bars’ cross-section is allowed.The bus duct shall be painted after suitable pretreatment of all structural steel and plates with anti-corrosive epoxy base primer paint & two coats of anti corrosive epoxy basepaint externally with a colour of pebble / flint gray shade RAL 7032and dried in a oven. The enclosure shall conform toIP: 54 for indoor, as per Indian Standards. Inner surface of the bus – duct shall be coated in the rubber paint.
307The bare bus –bars shall be provided with a coat of Matt finish, The joints in the bus –bars shall be of the bolted type and it shall be ensured that the following precautions are observed.i). The contact pressure must be ample and this shall be maintained during the time the panel is in service. ii. The surfaces of the conductors must be clean. iii. With flat conductors, the overlap should be equal to or greater than the width of the bars or ten times the thickness of the bar whichever is greater iv. The joints shall be treated by the application of joint compound to render the joint moisture-proof. v. For the joints use of bolts of cadmium plated high-tension MS bolts having expansion characteristics due to temperature change similar to the conductor may be used with steel nuts. vi. Smearing the surfaces with oxide inhibiting grease just prior to making the joint in order to preserve the efficiency of the joints.
308The joints in the bus –bars shall be of the bolted type and it shall be ensured that the following precautions are observed. i). The contact pressure must be ample and this shall be maintained during the time the panel is in service. ii. The surfaces of the conductors must be clean. iii. With flat conductors, the overlap should be equal to or greater than the width of the bars or ten times the thickness of the bar whichever is greater iv. The joints shall be treated by the application of joint compound to render the joint moisture-proof. v. For the joints use of bolts of cadmium plated high-tension MS bolts having expansion characteristics due to temperature change similar to the conductor may be used with steel nuts. vi. Smearing the surfaces with oxide inhibiting grease just prior to making the joint in order to preserve the efficiency of the joints. Minimum phase and earth clearance required shall be maintained at joints. The joints shall bethoroughly shrouded.The bus bar arrangement shall generally conform to IS: 5578 and IS: 11353. The bus – duct shall be also supplied with suitable earth bus running all along the length of the bus – duct made
309of copper strips. Current density at any part shall notexceed prescribed limits. Two copper flats of same phase shall be stacked together or the spacing between them shall be maximum of the thickness of one conductor. The busbars shall be phase identified by colour, at intervals. Colour code shall be RED, YELLOW and BLUE for phase and BLACK for the neutral bus – bar. Bus – bars shall be supported on tough, non-hygroscopic, resin bonded self-extinguishing fire retardant insulators preferably of SMC / DMC with ribbed construction to prevent tracking due to dust paths. Bus – bars and supports shall withstand the maximum stresses that are induced in the event of. The short-circuit currents being as specified. The bus – bar support shall be at a minimum interval of 500mm. 5 Deg.C above the ambient. The clearance between the individual bare phase power bus – bars and between the phase and earth bus –bars in air shall be not less than 25 mm and 19 mm respectively. (Qtn Enclosed)
310Design, Supply, erection, testing and commissioning of 1600A aluminium Flexible end joints (R,Y,B &N) from Bus duct end to 1600A LTACB 1&2 termination end and Bus duct end to 1000 KVA Transformer 1 &2 bushing . The bus–bars joints shall be supplied with flexible expansion joints at both the ends and also at bends. The supports and expansion arrangement shall be so chosen to avoid undue stress to the bus – bars, supports and end connections.(1000 KVA TR 1&2 Secondary side-1 Set/ Each,1600A LT ACB 1&2 Incoming side-1Set/ Each(Qtn Enclosed)
311Design, Supply, erection, testing and commissioning of 2500A aluminium Bus Ducts made up of 16 SWG sheet steel minimum thickness of 1.8 mm bolted on to an angle iron / structural steel framework.covers the requirements of 3 phase 415 V, 50 Hz, 1600A continuous rated, aluminiumTPN bus with enclosure suitable for Outdoor type. The bus – duct shall be designed for the above current ratings and for a maximum temperature rise of 400C over an ambient temperature of 45°C. The bus – bars shall be of hard drawn high conductivity electrolytic grade copper flats of size 2Runs x 50mm x12mmelectrical grade 63401-WP as per IS: 5082 The bus- bars shall be of uniform cross section along its entire length. No tapering of the bus bars’ cross-section is allowed. The bus duct shall be painted after suitable pretreatment of all structural steel and plates with anti-corrosive epoxy base primer paint & two coats of anti corrosive epoxy base paint externally with a colour of pebble / flint gray shade RAL 7032and dried in a oven. The enclosure shall conform toIP: 54 for indoor, as per Indian Standards. Inner surface of the bus – duct shall be coated in the rubber paint.The bare bus –bars shall be provided with a coat of Matt finish, The joints in the bus –bars shall be of the bolted type and it shall be ensured that the following p
312precautions are observed. i). The contact pressure must be ample and this shall be maintained during the time the panel is in service. ii. The surfaces of the conductors must be clean. iii. With flat conductors, the overlap should be equal to or greater than the width of the bars or ten times the thickness of the bar whichever is greater iv. The joints shall be treated by the application of joint compound to render the joint moisture-proof. v. For the joints use of bolts of cadmium plated high-tension MS bolts having expansion characteristics due to temperature change similar to the conductor may be used with steel nuts. vi. Smearing the surfaces with oxide inhibiting grease just prior to making the joint in order to preserve the efficiency of the joints. of aluminium strips. Current density at any part shall notexceed prescribed limits. Two copper flats of same phase shall be stacked together or the spacing between them shall be maximum of the thickness of one conductor. The busbars shall be phase identified by colour, at intervals. Colour code shall be RED, YELLOW and BLUE for phase and BLACK for the neutral bus – bar. Bus – bars shall be supported on tough, non-hygroscopic, resin bonded self-extinguishing fire retardant insulators preferably of SMC / DMC with ribbed construction to prevent tracking due to dust paths. Bus – bars and supports shall withstand the maximum stresses that are
313shall withstand the maximum stresses that are induced in the event of. The short-circuit currents being as specified. The bus – bar support shall be at a minimum interval of 500mm. 5 Deg.C above the ambient. The clearance between the individual bare phase power bus – bars and between the phase and earth bus –bars in air shall be not less than 25 mm and 19 mm respectively. (Qtn Enclosed)
314Design, Supply, erection, testing and commissioning of 2500A aluminium Flexible end joints (R,Y,B &N) from Bus duct end to 2500A LTACB 1&2 termination end and Bus duct end to 1600 KVA Transformer 1 &2 bushing . The bus–bars joints shall be supplied with flexible expansion joints at both the ends and also at bends. The supports and expansion arrangement shall be so chosen to avoid undue stress to the bus – bars, supports and end connections.(1600 KVA TR 1&2 Secondary side-1 Set/ Each,2500A LT ACB 1&2 Incoming side-1Set/ Each(Qtn Enclosed)
315MV PANEL-1:-Design, Supply, erection, testing and commissioning of 5000A floor mounted MV cubical panel board bus bar chamber dust and vermin proof and accommodating the following switch and 2 Nos.2500A ACB as Incomer units with the following items of work complete to satisfy the latest IS rules and CEIG guidelines. Supply and fixing of suitable size bus bar chamber made up of 16 SWG MS sheet steel with 4 Nos ie R,Y,B,N.of 2 Runs 6” X 1/2” ( 2 Runs x150mm x 12mm) tinned copper bus bar for 3 phases and neutral and 2 Nos. of earthing bus of size 1”X ¼ (2 x 25mm x6mm)tinned copper bus on suitable bus bar insulator (Epoxy insulator)With maximum creepage distance and supported on MS Base channel frame work ofsize 4”X2”X¼-1Set(100mm x50mm x6mm) Incoming:-1)Supply and fixing of 2 Nos. 2500A basic rating 4 pole 433V LT ACB confirming to IS 13947 – 2 IEC 60947 – 2 for higherbreaking capacities of 70KA at 690V AC with all accessories for standard horizontal manual draw out type ACB equipped with auxiliary contacts and all accessories for closing and opening operation with micro processor SR 18 G relay, over current trip device
316adjustable to LTD, STD and release for over current protection UV release with time delay, EF release short circuit protection, Mains CTs for 3 phases lockout, features, separate mould base for each pole
317for easy maintenance all relevant protection safety accessories as per CEIG, IE rules inforce with interconnection and terminations as required in specification. 2)BUS COUPLER:- Supply and fixing of 1 No 5000A basic rating 4 pole 433 VLT ACB to IS-1394721EC60947-2 600VAC with all accessories for standard horizontal type ACB equipped with Microprocessor based SR18G(w/o protection).Outgoing:- 1)Supply and fixing of 2500A basic rating 4 pole 433V LT ACB confirming to IS 13947 – 2 IEC 60947 – 2 for higherbreaking capacities of 65KA at 690V AC with all accessories for standard horizontal manual draw out type ACB equipped with auxiliary contacts and all accessories for closing and opening operation with micro processor SR 18 G relay, over current trip device adjustable to LTD, STD and release for over current protection UV release with time delay, EF release short circuit protection, Mains CTs for 3 phases lockout, features, separate mould base for each pole- 2Nos 2)Supply and fixing of 800A TP MCCB with extended Rotary handle and Spreader terminals -2Nos 3)Supply and fixing of 250A TP MCCB with extended Rotary handle and Spreader terminals --2Nos
318Inter connecting the all LT ACB’s and MCCBs to two bus bar with suitable insulated tinned copper flats and painting of phases and neutral indication Double Earth connection of the MCCBs and ACB’s to earth bus using suitable tinned copper flats by 2 runs of 1” X 1/8”Supply and fixing of LED lamp arrangements with toggle switches to the control to each phases and with rigid connection in suitable separate compartments with in the cubicle by CEIG rules with , 2 sets, of supply and fixingElectronic Trivector EC, 300P class 0.5 Base mounting L&T or equivalent.(Make–Model. ER300P class 0.5)Double Earth connection of the MCCBs and ACB’s to earth bus using suitable tinned copper flats by 2 runs of 1” X 1/8” .Supply and fixing of danger board with siemens grey powder coatingwith super scribing the names of places to whichsupply is fed feeder sizes ofcables direction of cables etc.Erection of panel board complete with suitable foundation bolts and nuts including suitable M.S Channel,concreting, testingand commissioning (L&T/Siemens/Legrand) (Qtn Enclosed)
319MV PANEL:2-Design, Supply, erection, testing and commissioning of 3200A floor mounted MV cubical panel board bus bar chamber dust and vermin proof and accommodating the following switch and 2 Nos.1600A ACB as Incomer units with the following items of work complete to satisfy the latest IS rules and CEIG guidelines. Supply and fixing of suitable size bus bar chamber made up of 16 SWG MS sheet steel with 4 Nos ie R,Y,B,N.of 4” X 1/2”( 100mm x 12mm) tinned copper bus bar for 3 phases and neutral and 2 Nos. of earthing bus of size 1”X ¼ (2 x 25mm x6mm)tinned copper bus on suitable bus bar insulator (Epoxy insulator)With maximum creepage distance and supported on MS Base channel frame work ofsize 4”X2”X¼-1Set(100mm x50mm x6mm) Incoming:-1)Supply and fixing of 2 Nos. 1600A basic rating 4 pole 433V LT ACB confirming to IS 13947 – 2 IEC 60947 – 2 for higherbreaking capacities of 65KA at 690V AC with all accessories for standard horizontal manual draw out type ACB equipped with auxiliary contacts and all accessories for closing and opening operation with micro processor SR 18 G relay, over current trip device adjustable to LTD, STD and release for over current protection UV release with time delay, EF release short circuit protection, Mains CTs for 3 phases lockout, features, separate mould base for each pole
320for easy maintenance all relevant protection safety accessories as per CEIG, IE rules inforce with interconnection and terminations as required in specification. 2)BUS COUPLER:- Supply and fixing of 1 No 3200A basic rating 4 pole 433 VLT ACB to IS-1394721EC60947-2 600VAC with all accessories for standard horizontal type ACB equipped with Microprocessor based SR18G(w/o protection).Outgoing:- 1) Supply and fixing of 1000A TP MCCB with extended Rotary handle and spreader terminal --2Nos 2)Supply and fixing of 800A TP MCCB with extended Rotary handle and Spreader terminals --2Nos 3)Supply and fixing of 400A TP MCCB with extended Rotary handle and Spreader terminals -2Nos 4)Supply and fixing of 125A TP MCCB with extended Rotary handle and Spreader terminals --2NosInter connecting the all LT ACB’s and MCCBs to two bus bar with suitable insulated tinned copper flats and painting of phases and neutral indication Double Earth connection of the MCCBs and ACB’s to earth bus using suitable tinned copper flats by 2 runs of 1” X 1/8”Supply and fixing of LED lamp
321arrangements with toggle switches to the control to each phases and with rigid connection in suitable separate compartments with in the cubicle by CEIG rules with , 2 sets, of supply and fixingElectronic Trivector EC, 300P class 0.5 Base mounting L&T or equivalent.(Make–Model. ER300P class 0.5)Double Earth connection of the MCCBs and ACB’s to earth bus using suitable tinned copper flats by 2 runs of 1” X 1/8” .Supply and fixing of danger board with siemens grey powder coatingwith super scribing the names of places to whichsupply is fed feeder sizes ofcables direction of cables etc.Erection of panel board complete with suitable foundation bolts and nuts including suitable M.S Channel,concreting, testingand commissioning (L&T/Siemens/Legrand)(Qtn Enclosed)
322Design, Supply, erection, testing and commissioning of 1000A aluminium vertical Raising main made up of 16 SWG sheet steel minimum thickness of 1.8 mm bolted on to an angle iron / structural steel framework.covers the requirements of 3 phase 415 V, 50 Hz, 1000A continuous rated, copper TPN bus with enclosure suitable for indoor type. The bus – duct shall be designed for the above current ratings and for a maximum temperature rise of 400C over an ambient temperature of 45°C. The bus – bars shall be of hard drawn high conductivity electrolytic grade aluminium flats of size 1Run of 150mm x12mmelectrical grade 63401-WP as per IS: 5082 The bus- bars shall be of uniform cross section along its entire length. No tapering of the bus bars’ cross-section is allowed. The bus duct shall be painted after suitable pretreatment of all structural steel and plates with anti-corrosive epoxy base primer paint & two coats of anti corrosive epoxy basepaint externally with a colour of pebble / flint gray shade RAL 7032and dried in a oven. The enclosure shall conform toIP: 54 for indoor, as per Indian Standards. Inner surface of the bus – duct shall be coated in the rubber paint.The bare bus –bars shall be provided with a coat of Matt finish, The joints in the bus –bars shall be of the bolted type and it shall be ensured that the
323following precautions are observed.i). The contact pressure must be ample and this shall be maintained during the time the panel is in service. ii. The surfaces of the conductors must be clean. iii. With flat conductors, the overlap should be equal to or greater than the width of the bars or ten times the thickness of the bar whichever is greater iv. The joints shall be treated by the application of joint compound to render the joint moisture-proof. v. For the joints use of bolts of cadmium plated high-tension MS bolts having expansion characteristics due to temperature change similar to the conductor may be used with steel nuts. vi. Smearing the surfaces with oxide inhibiting grease just prior to making the joint in order to preserve the efficiency of the joints. Minimum phase and earth clearance required shall be maintained at joints. The joints shall bethoroughly shrouded.The bus bar arrangement shall generally conform to IS: 5578 and IS: 11353. The bus – duct shall be also supplied with suitable earth bus running all along the length of the bus – duct made of copper strips. Current density at any part shall notexceed prescribed limits. Two copper flats of same phase shall be stacked together or the spacing between them shall be maximum of the thickness of one conductor. The busbars shall be phase identified by colour, at intervals.
324Colour code shall be RED, YELLOW and BLUE for phase and BLACK for the neutral bus – bar. Bus – bars shall be supported on tough, non-hygroscopic, resin bonded self-extinguishing fire retardant insulators preferably of SMC / DMC with ribbed construction to prevent tracking due to dust paths. Bus – bars and supports shall withstand the maximum stresses that are induced in the event of. The short-circuit currents being as specified. The bus – bar support shall be at a minimum interval of 500mm. 5 Deg.C above the ambient. The clearance between the individual bare phase power bus – bars and between the phase and earth bus –bars in air shall be not less than 25 mm and 19 mm respectively. (Qtn Enclosed)
325Supply and fixing of End feed unit 1000A 4Pole MCCB with enclosure Fixing on 1000A vertical Raising Main control for main lighting floor wise panel . Interconnection between Raising main bus bar to 1000A 4pole MCCB terminal to connect the suitable alu. flats(100mm x12mm) complete connectin etc.The MCCBs shall be of L&T/ Hagarmake.
326Supply and fixing of top off box 250A 4Pole MCCB with enclosure Fixing on 1000A vertical Raising Main for main lighting floor wise panel / metering panel. Interconnection between Raising main bus bar to 250A 4pole MCCB terminal to connect the suitablealu. flats (25mm x12mm) complete connectin etc.The MCCBs shall be of L&T/ Hagarmake.
327Supply and fixing of top off box 400A 4Pole MCCB with enclosure Fixing on 1000A vertical Raising Main for main lighting floor wise panel / metering panel. Interconnection between Raising main bus bar to 400A 4pole MCCB terminal to connect the suitablealu flats (65mm x 3mm)complete connectin etc.The MCCBs shall be of L&T/ Hagarmake.
328Supply and fixing of top off box 630A 4Pole MCCB with enclosure Fixing on 1000A vertical Raising Main for main lighting floor wise panel / metering panel. Interconnection between Raising main bus bar to 630A 4pole MCCB terminal to connect the suitablealu. flats (75mm x 8mm)complete connectin etc.The MCCBs shall be of L&T/ Hagarmake.
329Supply, Eection,testing and commissioningofcubical type 9 nos service metering panel boardofsize 1950mm Length x2200m Breadth x300mm Heightsuitable for 3 phase 400/440V 50 Hz A.C supply made up of 16 SWG sheet steel with necessary A.I frame and M.S flat supports with door arrangements on the front for the following: 1.Copper Bus bar chamber-1 No.(50mm X6mm Copper Flat) 2. Metering chamber-9 Nos Three phase 3. Cable entry chambers4.100A TPN MCCB chamber-9Nos . 5.100A Fuse unit-9 set (Each set-3 Nos) 6.100A Neautral link-9 nos The panel board to be dust and vermin proof mounted on channels/angles on wall/floor including minor civil works,with painting by powder coating. The bus bar chambers to comprise of1) Supply and fixing of 400A TPN MCCB-1no for 50 x6mm Copper flat for 3 phase and neutral with accomodate for Three phase meter 100A Direct Meter(Meter supplied by contractor) and 2nos 1”x1/8” earth bus (both inter- connected). The bus bar to be mounted on suitable bus bar insulators with hylum sheet separators and with RYB
330indication.The metering chamber to comprise of the following service connection arrangements.1 ) 9Nos Three Phase service connection The metering panel should be with separate compartment for housing the energy meter with suitable view glass with 9 Nos S&F of 100 Amps TPN MCCB for the Three phase supply for direct energy Meter in a separate compartment with doors, lock & key arrangements and with suitable cable entry boxex etc., Necessary inter connection between energy meter and bus bar to be provided with suitable rigid copper wire connection of the MCCB"s and door frames etc., to be provided with suitable copper wire/ conductor.The service to be stencil marked with Shop number ,capacity,cable size etc.,and the cables to be terminat with suitable copper. Sockets by crimping.The doors and all covers of the panel board should be suitably provided for sealing arrangements to avoid any tampering of the main supply completely etc. at Ground Floor-1 No & Fifth Floor-1 No (Qtn Enclosed)
331Supply, Eection,testing and commissioningofcubical type 15 nos service metering panel boardofsize 2925mm Length x2200m Breadth x300mm Heightsuitable for 3 phase 400/440V 50 Hz A.C supply made up of 16 SWG sheet steel with necessary A.I frame and M.S flat supports with door arrangements on the front for the following: 1.Copper Bus bar chamber-1 No.(40mm X10mm Copper Flat) 2. Metering chamber-15 Nos Three phase 3. Cable entry chambers4.100A TPN MCCB chamber-15Nos5.100A Fuse unit-15 set (Each set-3 Nos) 6.100A Neautral link-15 nos The panel board to be dust and vermin proof mounted on channels/angles on wall/floor including minor civil works,with painting by
332powder coating. The bus bar chambers to comprise the supply and fixing of1) 630A MCCB-1no for 40mm x 10mm Copper flat for 3 phase and neutral with accomodate for Three phase meter 100A Direct Meter(Meter supplied by contractor) and 2nos 1”x1/8” earth bus (both inter- connected). The bus bar to be mounted on suitable bus bar insulators with hylum sheet separators and with RYB indication.The metering chamber to comprise of the following service connection arrangements.
3331 ) 15Nos Three Phase service connection The metering panel should be with separate compartment for housing the energy meter with suitable view glass with 15 Nos S&F of 100 Amps TPN MCCB for the Three phase supply for direct energy Meter in a separate compartment with doors, lock & key arrangements and with suitable cable entry boxex etc., Necessary inter connection between energy meter and bus bar to be provided with suitable rigid copper wire connection of the MCCB"s and door frames etc., to be provided with suitable copper wire/ conductor.The service to be stencil marked with Shop number ,capacity,cable size etc.,and the cables to be terminat with suitable copper. Sockets by crimping.The doors and all covers of the panel board should be suitably provided for sealing arrangements to avoid any tampering of the main supply completely etc. at First Floor-1 No, Second Floor-1 No & Third Floor-1 No (Quotation Enclosed)
334Supply, Eection,testing and commissioningofcubical type 11 nos service metering panel boardofsize 2275mm Length x2200m Breadth x300mm Heightsuitable for 3 phase 400/440V 50 Hz A.C supply made up of 16 SWG sheet steel with necessary A.I frame and M.S flat supports with door arrangements on the front for the following: 1.Copper Bus bar chamber-1 No.(40mm X10mm Copper Flat) 2. Metering chamber-11 Nos Three phase 3. Cable entry chambers4.100A TPN MCCB chamber-11Nos5.100A Fuse unit-11 set (Each set-3 Nos) 6.100A Neautral link-11 nos The panel board to be dust and vermin proof mounted on channels/angles on wall/floor including minor civil works,with painting by
335powder coating. The bus bar chambers to comprise the supply and fixing of1) 630A MCCB-1no for 40mm x 10mm Copper flat for 3 phase and neutral with accomodate for Three phase meter 100A Direct Meter(Meter supplied by contractor) and 2nos 1”x1/8” earth bus (both inter- connected). The bus bar to be mounted on suitable bus bar insulators with hylum sheet separators and with RYB indication.The metering chamber to comprise of the following service connection arrangements.
3361 ) 11Nos Three Phase service connection The metering panel should be with separate compartment for housing the energy meter with suitable view glass with 11 Nos S&F of 100 Amps TPN MCCB for the Three phase supply for direct energy Meter in a separate compartment with doors, lock & key arrangements and with suitable cable entry boxex etc., Necessary inter connection between energy meter and bus bar to be provided with suitable rigid copper wire connection of the MCCB"s and door frames etc., to be provided with suitable copper wire/ conductor.The service to be stencil marked with Shop number ,capacity,cable size etc.,and the cables to be terminat with suitable copper. Sockets by crimping.The doors and all covers of the panel board should be suitably provided for sealing arrangements to avoid any tampering of the main supply completely etc. at Fifth Floor-1 No. (Quotation Enclosed)
337Lift Panel :-400A Panel at 8th Floor:-Design, Supply, erection, testing and commissioning of 400Afloor mounted cubical panel board bus bar chamber dust and vermin proof and accommodating the following d sine with Thermal Magnetic Release MCCB’s Incomer &outgoing units with the following items of work complete to satisfy the latest IE rules and CEIG guidelines. Supply and fixing of suitable bus bar chamber made up of 16SWG MS sheet steel(1.6mm) with 4 Nos. of2” X ¼ ” tinned copper bus bar for 3 phases and neutral (50mm x 6mm) and 2Nos. of ear thing bus of size 1” X 1/8 tinned copper bus(25mm x 3mm) on suitable bus bar insulator(Epoxy insulator) with maximum cree page distance and supported on MS Base channel frame work of size 4”X 2”X ¼”–1Set Incoming 1)Supply and fixing of 400A 4pole MCCB with spreader link and rotary handle -1No Outgoing 1)Supply and fixing of 100A 3Pole MCCB with spreader link and rotary handle—5Nos, 2)Instrument panel-1 set
338Inter connecting the all LT MCCB’s to bus bar with suitable insulated tinned copper flats and painting/PVC sleevecolour coding of phases and neutral indication. Double Earth connection of theMCCB’s to earth bus colour coding of phases and neutral indication. Double Earth connection of the MCCB’s to earth bus using suitable tinned copper flats by 2 runs of 1” X 1/8” Supply and fixing of LED lamp arrangements with toggle switches to the control to each phases and with rigid connection in suitable separate compartments within the cubicle by CEIG rules with , 1 set of supply and fixing Electronic Multifunction Meter class 0.2S flush mounting L&T or equivalent make. Supply and fixing of danger board withSiemens grey powder coating with super Scribing the names of places to which supply is fed feeder sizes of cables direction of cables etc. Erection of panel board complete with suitable foundation bolts and nuts including suitable M.S Channel, concreting, testing and commissioning complete etc,.(L&T, C&S, SIEMENS, ABB)(Qtn Enclosed)
339Supply and laying of4R X 3½ x400 sq.mm XLPEarmoured LTUG cable in a trench to be excavated at a depth of 0.75 Mtr Putting 0.15mt layer of sand and covering thecable with suitable HDPE Pipe and refilling the earth to make good.
340Supply and Laying of 4R X 3½ x400 sq.mm PVC LTUG armored cable on post or on wall / existing trench with MS Clamps.
341Supply and fixing of brass cable gland for 3½x 400 sq mm PVC armored LTUG cable with earth connection
342Supply and providing cable end termination of3½ x 400 sq mm PVC LTUG aluminium armored cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete
343Design, fabrication, supply,erection,Testing and Commisioning of300 KVAR APFC Pnael for the followingcubicle type floor mountingarrangement made out of MS sheet steel enclosure withbus bar chamber and suitable size copper busbar, cable chamber, interconnection, wiring with paintingas per specifications attached including necessary control wiring for automatic correction of capacitors Incomer: i) 1 No. 1000A TPN 50KA MCCB and with16 stage APFC Relay manual closing mechanism of 35 KA rating with thermal and magnetic short circuit protection.1 set 1000A/5A CT CL 1.0 15 VA for metering1 No - Digital type ammeter with built in selectorswitch conzerv - DM 13581 No - Digital type voltmeter with built in selectorswitch conzerv - (DM 1357)1 set - LED type RYB indication lamp with controlMCBs.1 no - 16 stage automatic power factor correction relay Bus Bars,1000 Amps 3 phase 4 wire Copper bus bar Outgoing 1 Set comprising of: i) 4Nos 50KVAR MPP(H)capacitor each with capacitorduty contactors and 200A TP MCCB ii) 2 Nos 25KVAR MPP(H)capacitor each withcapacitor duty contactors and 125A TP MCCB iii) 1 Nos 20KVAr MPP(H)capacitor each withcapacitor duty contactors and 100A TP MCCB
344iv) 1 No 10KVAr MPP(H)capacitor each with capacitor duty contactors and 63A TP MCB v) 2 Nos 7.5KVAr MPP(H)capacitor each with capacitor duty contactors and 63A TP MCBvi) 1 No 5KVAr MPP(H)capacitor each with capacitorduty contactors and 63A TP MCB,with complete connection etc (@ MV Panel room)
345Supply and clarnping of3½ x240 sq.mm PVC LTUG armored LTUG cable on post or on wall/existing trench with MS Clamps.
346Supply and fixing of brass cable gland for 3½x 240 sq mm PVC armored LTUG cable with earth connection
347Supply and providing cable end termination of3½ x240 sq mm PVC LTUG aluminium armored cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete
348Design, Supply, erection, testing and commissioning of 2500A aluminium flat of size 8"" x 1/2""(200mm x 12mm )vertical Raising main made up of 16 SWG sheet steel minimum thickness of 1.8 mm bolted on to an angle iron / structural steel framework.covers the requirements of 3 phase 415 V, 50 Hz, 2500A continuous rated, copper TPN bus with enclosure suitable for indoor type. The bus – duct shall be designed for the above current ratings and for a maximum temperature rise of 400C over an ambient temperature of 45°C. The bus – bars shall be of hard drawn high conductivity electrolytic grade alu.flats of size 2Runs of 150mm x12mmelectrical grade 63401-WP as per IS: 5082 The bus- bars shall be of uniform cross section along its entire length. No tapering of the bus bars’ cross-section is allowed. The bus duct shall be painted after suitable pretreatment of all structural steel and plates with anti-corrosive epoxy base primer paint & two coats of anti corrosive epoxy base paint externally with a colour of pebble / flint gray shade RAL 7032and dried in a oven. The enclosure shall conform toIP: 54 for indoor, as per Indian Standards. Inner surface of the bus – duct shall be coated in the rubber paint.The bare bus –bars shall be provided with a coat of Matt finish, The joints in the bus –bars shall be of the bolted type and it shall be ensured that the
349following precautions are observed.i). The contact pressure must be ample and this shall be maintained during the time the panel is in service. ii. The surfaces of the conductors must be clean. iii. With flat conductors, the overlap should be equal to or greater than the width of the bars or ten times the thickness of the bar whichever is greater iv. The joints shall be treated by the application of joint compound to render the joint moisture-proof. v. For the joints use of bolts of cadmium plated high-tension MS bolts having expansion characteristics due to temperature change similar to the conductor may be used with steel nuts. vi. Smearing the surfaces with oxide inhibiting grease just prior to making the joint in order to preserve the efficiency of the joints. Minimum phase and earth clearance required shall be maintained at joints. The joints shall bethoroughly shrouded.The bus bar arrangement shall generally conform to IS: 5578 and IS: 11353. The bus – duct shall be also supplied with suitable earth bus running all along the length of the bus – duct made of copper strips. Current density at any part shall notexceed prescribed limits. Two copper flats of same phase shall be stacked together or the spacing between them shall be maximum of the thickness of one conductor.
350The busbars shall be phase identified by colour, at intervals.Colour code shall be RED, YELLOW
351and BLUE for phase and BLACK for the neutral bus – bar. Bus – bars shall be supported on tough, non-hygroscopic, resin bonded self-extinguishing fire retardant insulators preferably of SMC / DMC with ribbed construction to prevent tracking due to dust paths. Bus – bars and supports shall withstand the maximum stresses that are induced in the event of. The short-circuit currents being as specified. The bus – bar support shall be at a minimum interval of 500mm. 5 Deg.C above the ambient. The clearance between the individual bare phase power bus – bars and between the phase and earth bus –bars in air shall be not less than 25 mm and 19 mm respectively. (Quotation Enclosed)
352Supply and fixing of End feed unit 1Nos.2500A ACB as Incomer units with the following items of work complete to satisfy the latest IS rules and CEIG guidelines. Supply and fixing of suitable size bus bar chamber made up of 16 SWG MS sheet steel with 4 Nos ie R,Y,B,N.of 2 Runs 6” X 1/2”(2 Runs x150mm x 12mm) alu. bus bar for 3 phases and neutral and 2 Nos. of earthing bus of size 1”X ¼ (2 x 25mm x6mm)tinned copper bus on suitable bus bar insulator (Epoxy insulator)With maximum creepage distance and supported on MS Base channel frame work ofsize 4”X2”X¼-1Set(100mm x50mm x6mm)2500A verticalRaising Main control for AC Chiller unit panel . Interconnection between Raising main bus bar to 2500A 4pole ACB terminal to connect the suitable alu. flats complete connectin etc.The ACBs shall be of L&Tmake. (Quotation Enclosed)
353Supply and fixing of top off box 250A 4Pole MCCB with enclosure Fixing on 2500A vertical Raising Main for power load, Interconnection between Raising main bus bar to 250A 4pole MCCB terminal to connect the suitable alu. flats complete connectin etc.The MCCBs shall be of L&T/ Hagarmake
354AC Chiller Unit Panel:-Design, Supply, erection, testing and commissioning of 2500A floor mounted ACcubical panel board bus bar chamber dust and vermin proof and accommodating the following MCCB"s and 1 Nos.2500A ACB as Incomer units with the following items of work complete to satisfy the latest IS rules and CEIG guidelines. Supply and fixing of suitable size bus bar chamber made up of 16 SWG MS sheet steel with 4 Nos ie R,Y,B,N.of 2Runs x 3” X 1/2”(2 Runs x 75mm x 12mm) tinned copper bus bar for 3 phases and neutral and 2 Nos. of earthing bus of size 1”X ¼ (2 x 25mm x6mm)tinned copper bus on suitable bus bar insulator (Epoxy insulator)With maximum creepage distance and supported on MS Base channel frame work ofsize 4”X2”X¼-1Set(100mm x50mm x6mm)Incoming:-1)Supply and fixing of 1Nos. 2500A basic rating 4 pole 433V LT ACB confirming to IS 13947 – 2 IEC 60947 – 2 for higherbreaking capacities of 65KA at 690V AC with all accessories for standard horizontal manual draw out type ACB equipped with auxiliary contacts and all accessories for closing and opening operation with micro processor SR 18 G relay, over current trip device adjustable to LTD, STD and release for over current protection
355UV release with time delay, EF release short circuit protection, Mains CTs for 3 phases lockout, features, separate mould base for each pole for easy maintenance all relevant protection safety accessories as per CEIG, IE rules inforce with interconnection and terminations as required in specification.Outgoing:- 1) Supply and fixing of 800A TP MCCB with extended Rotary handle and spreader terminal --4Nos(Setting 630A) 2)Supply and fixing of 630A TP MCCB with extended Rotary handle and Spreader terminals -1No 3)Supply and fixing of 400A TP MCCB with extended Rotary handle and Spreader terminals --2NosInter connecting the all LT ACB’s and MCCBs to two bus bar with suitable insulated tinned copper flats and painting of phases and neutral indication Double Earth connection of the MCCBs and ACB’s to earth bus using suitable tinned copper flats by 2 runs of 1” X 1/8”Supply and fixing of LED lamp arrangements with toggle switches to the control to each phases and with rigid connection in suitable separate compartments with in the cubicle by CEIG rules with , 2 sets, of supply and fixingElectronic Trivector EC, 300P class 0.5 Base mounting L&T or
356equivalent.(Make–Model. ER300P class 0.5)Double Earth connection of the MCCBs and ACB’s to earth bus using suitable tinned copper flats by 2 runs of 1” X 1/8” .Supply and fixing of danger board with siemens grey powder coatingwith super scribing the names of places to whichsupply is fed feeder sizes ofcables direction of cables etc.Erection of panel board complete with suitable foundation bolts and nuts including suitable M.S Channel,concreting, testingand commissioning (L&T/Siemens/Legrand) (Quotation Enclosed)
357Charges for shifting ofRemoving and re-erection of 11 KV630 KVA Outdoor Transformer andDisconnecting the incoming primary side HT UG Cables and secondary side LTUG Cable size of 3 Runs x 3 1/2 x400 sqmm with complete service with Oil filteration for the above 630 KVA Transformer with testing report complete.The 630 KVA Transformerusing thecrane for loading and unloading , installation of Outdoor type with 1 mtr height all round brick wall with PCC (Plain cement concrete) foundation on the angle iron frame workfor Transformer wheel arrest suitable size including testing and commissioning completeetc. (Quotation Enclosed)
358Wiring with 2 x 1.5 sqmm (22 / 0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessorieswith TW switch box with 5A F.T switch in flush with wall covered with hylem sheet of 3mm thick with painting of suitable colour for open PVC light/fan point(For electronic regulator). 5 points per coil
359Wiring with 2x4 sqmm(56/0.3) PVC insulated SC unsheathed Cu.Conductor cable of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories,with 150mm x 100mm x 113mm TW switch box for 15A 3 pin non interlocking wall socketwith 15A Flush type switch with painting of suitableccolour with continuous earth wire connection of 14 SWG TC wire for open PVC powerplug point
360Supply and fixing of 20w LED. fittting (Box type model)wall mounted LED Battern, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver with conduit pipe suspension from ceiling with PVC unsheathed Copper leads from terminals to the fittings and with necessary connection
361Supply and fixing of 1200 mm (48") AC ceiling fan complete with stepped electronic 300W regulator with 1 1 meter down rod on the existing clamp
362Supply and fixing of48watts street light completewith single bracket of 32 mm dia GI pipe (Class "B") with 1 No 32mm GI Bend complete on the existing post wall with 16 A aerial fuse unit on MS plate with PVC unsheathed Copper leads MS clamps and aluminium painting with complete etc.
363Supply and fixing of 4way Verticaltype MCB Triple pole and neutral Distribution board ( Double door) in sheet steel enclosure with 63A 4pole MCB -1 No as incoming ,12 Nos 6A-32A SP MCBas outgoing on wallwith suitable angle iron frame work with earth connection complete etc. The MCB DB and MCBs shall be of Legrand make. @Outdoor Sub- Station 1&2- 1No/Each.
364Supply and fixing of 4Pole MCB enclosure with 4 pole 63A MCBon wallwith earth connection. The 4pole enclosure and MCBs shall be of /Legrand/ Hagarmake.
365Supply and fixing of 2Pole MCB enclosure with 2 pole 32A MCBon wallwith earth connection. The 2pole enclosure and MCBs shall be of /Legrand/ Hagarmake.
366Supply and clamping of 3 ½ x 35 sqmmPVC LTUG armoured cable on post or on wall with MS Clamps or existing trench/ existing cable Tray
367Supply and fixing of brass cable gland for3 ½ x 35 sqmmPVC LTUG armoured cable with earth connection .
368Supply and providing cable end termination of 3 ½ x35 sqmmf PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete.
369Supply, erection ,testing and commissioning of 5 KVA UPS system for the following configuration1) True ON LINE –UPS SYSTEMS with Pulse width modulation(PWM) Technology using IGBT Inverter.2) INPUT VOLTAGE RANGE : 170V-270V3)OUTPUT VOLTAGE : 230V ± 1% 4)DC Volt:120V5)INPUT FREQUENCY : 50Hz ± 5%6)Out put Frequency: 50Hz ± 2%7) Out put Waveform:Pure Sine Wave 8) LOAD POWER FACTOR : 0.8 toUnity9)HarmonicDistoration: Less than 5% 10)Over Load: : 125% for 10Minutes 11)Inverter Operation : PWM-IGBT 12)Invertor Efficience : BetterThan 90% 13)OPERATING TEMPERATURE : 0 to 50 Degrees centigrade’s on Full Load 14)Digital Panel Meter : To Read output A/C Volts,Output D/C Volts Frequency 15)By pass : Manual 16)PROTECTION (INBUILT) : a. Output Under Voltage b. Output Over Voltage c. Output Overload d. Output Short Circuit e. Battery Charging Current Limit.17)INDICATIONS :1. Mains On,2 Inverter On, 3. Load on U.P.S.4. Battery Low,5.Over load, 6.Inverter Trip.Outdoor Sub-Station 1& 2
370Earth Electrode:-Supply and installation maintenance free GI Earthing system comprising of 50mm dia and 2 mtr.long earth electrode of low carbon steel rod with 100 micron bonding and 25 kgs, of carbon based environment friendly backfill compound and suitable clamp (Galaxy /Ashlok or equivalent) for Transformer Neutral earth Tr 1&2 Each-2 Nos and RMG Surge-1 No and 3 panel HT VCB Surge-1 No & 2 Panel HT VCB surge-1 No
371Earthling as per ISI specification with an earth electrode of 2.1m class ‘B’ GI pipe ofdia not less than 40mm, with copper earth plate of size 125mm X 50mm X 6mm withnecessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry.
372Supply and run of 50mm x6mm (2” X 1/ 4”) copper flat with porcelain insulator with screws on wall/floor for earth connection.
373Supply and run of 25mm x6mm (1” X 1/ 4”) copper flat with porcelain insulator with screws on wall/floor for earth connection
374Supply and run of 25mm x 3mm (1” X 1/ 8”) copper flat with porcelain insulator with screws on wall/floor for earth connection
375Provision towards preparation of site plan, physical layout, electrical line schematic diagram HT side ,5 sets getting drawing approval from CEIG authority (Measures safety to electricity) regulation, preparation of completion report ,Rectification report, preparation of one set approved drawing and copy of safety certificate in a neat frame work and payment of CEIG "s inspection fees including supporting staff for availing service connection
376SAFETY ACCESSORIES:- Supply and Erecting of safety accessories . SR.XIII PART “M” 8Item (a) to (i)
377Supply, fixing, testing and commissioning of AC Chargeable emergency lamp 2 x 11W PL lamp with all connected accessories
378Supply and installation of 2.5mm thick Rubber Mat with ISI suitable for 1.1KV installation confirming to IS 15652 (5Nos=1set)
379Supply and Providing approved make First aid box complete with all first aid medicines
380Supply and providing shock treatment chart fixed in glass frame (Tamil and English)
381Supply and fixing of the 4nos fire buckets stand suitable for 4 nos fire buckets made out of 40 x 40 x6mm MS angle
382Supply of hand gloves 11 KV grade
383Supply and installation of Danger Board as required by the electrical authorities
384Supply and erection of Fire extinguisher Co2, 4.5 Kg confirming to TAC norms
385Earth Discharge Rod
386Design, Engineering, Fabrication,Supply, Erection, Testing,Commissioning and handing over of 13 Persons capacity Passenger lift (Gearless Lift with Machine Room) complete with the following specifications I. General Number of Lift : 1 No (a) Capacity and type 13 Persons Capacity Passenger lift. (b) Speed : 1 Mtr / Sec. (c) Drive : Micro Processor based VVVF (d) Size of Lift well : 2500 x 1900(MM Wide x MM Depth) as per IS 14665(partI)2000 to be constructed by PWD civil wing. (e) No. of floors : BL1,BL2,GF+ 8Floors. (f) Total height of Travel : 33.00 Metres. (g) No.of stops : 11 (BL1,BL2 ,GF + 8Upper Floor) (h) No.of opening : 11 ( BL1,BL2,GF + 8 Upper Floor) i) Construction of lift well : R.C.C. with brick masonry. (j) Power supply : AC 415/ 440 Volts, 3 phase, 50 Cycles. (k) Auxiliary supply : 230V, AC supply ( Single phase ) (l) Position of machinery : Directly above the lift well- Gearless. (m) Lift pit depth : 1600mm (n) Leveling accuracy : High level accuracy with smooth & jerk free travel and stopping.
387II. CAR a. Size of Lift Car inside : 2000mm width X1100mm b. Design of lift car: pre - coated Steel Grey & Blue. c. Car ceiling : Sleek (Small circular Lights). d. Car floor : Grey- 20mm Reccess. e. Car fittings : Stainless steel illuminating push button and 7 segments digital position indicator and overload indicator, 220V A/C electric fan 300mm swing, CFL fittings, UPS operated emergency alarm and light, floor announcement with musics, ADR function announcement. f. No. of Opening : One ,in front only g. Car Entrance : One ,in front only Power Operated centre opening sliding door-PreCoated steel-Grey. h. Clear opening : 900mm III. ENTRANCE a. Car Door : Power Operated centre opening sliding door- Pre-Coated steel-Grey. b. Landing Entrance Doors: Centre opening sliding door-Pre- Coated steel-Grey. c. Type of Entrance Frame: Pre-Coated stee Blue IV. OPERATION Microprocessor based Simplex Selective Collective control
388with / without attendant. V. Car and Landings : Digital floor position indicator in car and all landing. Dry cell operated alarm bell and emergency light with Automatic charging device, Up / Down Digital direction indications at all landings and in car. VI. LADDER FOR LIFT MACHINERY To be provided by the Lift contractor. VII. SPECIAL FEATURE : Digital position indicator in Car and landings. Battery operated Emergency light and Alarm bell, call register signal and VF Door operator, false ceiling in Car. Infra red door screen, Vandal proof SS Button with SS cover / Automatic Rescue Device,Over load indication,Fire mans switch, over load indicator and Intercom provisions with Instruments and floor Annunciator.SS hand rails and ON/OFF key and free service for 1year VIII. Automatic Rescue Device ( ARD ) : To facilitate landing of lift to the nearest floor at the time of power failure. This shall consist of suitable type battery system with charger, inverter, under voltage
389protection system etc. complete with all accessories. IX. MINOR BUILDER WORK : To be done by the lift contractor. X. SCAFFOLDING WORKS : To be done by the lift contractor. XI. FREE SERVICE AND MAINTENANCE DURING THE GUARANTEE PERIOD OF ONE YEAR & SAFTY CERTIFICATE a. Guarantee : Guarantee for materials and workmanship of equipment not less than one year. b. Free maintenance : Free comprehensive, servicing and maintenance during the guarantee period to be provided by the Lift contractor(1year) And important necessary training of employees, for minor maintenance works and proper handing over of lift to be done by the lift contractor. c. Site tests in accordance with IS 14665 shall be carried out at time of handing over. XII. OTHER INCLUSIONS : Over speed Governor, phase failure and phase reversal relay, alarm bell, T. Guide brackets for car and counter weights, rubber padding under winding unit, Motor of
390adequate capacity, Single reduction worm gear,electro magnetic brake with compression springs, car safety gear, buffer, electro mechanical door locks, tubular S.S hand rail in car. Steel ladder for machine room, Emergency key, motor overload protection devices, final limit switch, position and direction indicators for car and landing entrances, mainsuspension ropes, counter weights, lifting joists for mounting the machines S.S. facial plate for car operating panel & landing fixtures, fireman"s switch and other necessary controls, Overload Warning indicator with audio annuouncer, Provision for architraves covering all the three sides up to a Width of 300mm decolam sheet on plywood with TW Frame with aluminium beadings or suitable materials of the existing wall architraves should also cover the thickness of sill level of door frame at the landing and indicator boxes at all landings, full Width half height rear panel mirror complete set.
391Design, Engineering, Fabrication,Supply, Erection, Testing,Commissioning and handing over of 20 Persons capacity Passenger lift (Gearless Lift without Machine Room) complete with the following specifications I. General Number of Lift : 3 No (a) Capacity and type 20Persons Capacity Passenger lift. (b) Speed : 1 Mtr / Sec. (c) Drive : Micro Processor based VVVF (d) Size of Lift well : 2500 x 2400(MM Wide x MM Depth) as per IS 14665(partI)2000 to be constructed by PWD civil wing. (e) No. of floors : BL1,BL2,GF+ 8Floors. (f) Total height of Travel : 33.00 Metres. (g) No.of stops : 11 (BL1,BL2 ,GF + 8Upper Floor) (h) No.of opening : 11 ( BL1,BL2,GF + 8 Upper Floor) i) Construction of lift well : R.C.C. with brick masonry. (j) Power supply : AC 415/ 440 Volts, 3 phase, 50 Cycles. (k) Auxiliary supply : 230V, AC supply ( Single phase ) (l) Position of machinery : Directly above the lift well- Gearless. (m) Lift pit depth : 1600mm (n) Leveling accuracy : High level accuracy with smooth & jerk free travel and stopping.
392II. CAR a. Size of Lift Car inside : 2000mm width X1500mm b. Design of lift car: pre - coated Steel Grey & Blue. c. Car ceiling : Sleek (Small circular Lights). d. Car floor : Grey- 20mm Reccess. e. Car fittings : Stainless steel illuminating push button and 7 segments digital position indicator and overload indicator, 220V A/C electric fan 300mm swing, CFL fittings, UPS operated emergency alarm and light, floor announcement with musics, ADR function announcement. f. No. of Opening : One ,in front only g. Car Entrance : One ,in front only Power Operated centre opening sliding door-PreCoated steel-Grey. h. Clear opening : 900mm III. ENTRANCE a. Car Door : Power Operated centre opening sliding door- Pre-Coated steel-Grey. b. Landing Entrance Doors: Centre opening sliding door-Pre- Coated steel-Grey. c. Type of Entrance Frame: Pre-Coated stee Blue IV. OPERATION Microprocessor based Simplex Selective Collective control
393with / without attendant. V. Car and Landings : Digital floor position indicator in car and all landing. Dry cell operated alarm bell and emergency light with Automatic charging device, Up / Down Digital direction indications at all landings and in car. VI. LADDER FOR LIFT MACHINERY To be provided by the Lift contractor. VII. SPECIAL FEATURE : Digital position indicator in Car and landings. Battery operated Emergency light and Alarm bell, call register signal and VF Door operator, false ceiling in Car. Infra red door screen, Vandal proof SS Button with SS cover / Automatic Rescue Device,Over load indication,Fire mans switch, over load indicator and Intercom provisions with Instruments and floor Annunciator.SS hand rails and ON/OFF key and free service for 1year VIII. Automatic Rescue Device ( ARD ) : To facilitate landing of lift to the nearest floor at the time of power failure. This shall consist of suitable type battery system with charger, inverter, under voltage
394protection system etc. complete with all accessories. IX. MINOR BUILDER WORK : To be done by the lift contractor. X. SCAFFOLDING WORKS : To be done by the lift contractor. XI. FREE SERVICE AND MAINTENANCE DURING THE GUARANTEE PERIOD OF ONE YEAR & SAFTY CERTIFICATE a. Guarantee : Guarantee for materials and workmanship of equipment not less than one year. b. Free maintenance : Free comprehensive, servicing and maintenance during the guarantee period to be provided by the Lift contractor(1year) And important necessary training of employees, for minor maintenance works and proper handing over of lift to be done by the lift contractor. c. Site tests in accordance with IS 14665 shall be carried out at time of handing over. XII. OTHER INCLUSIONS : Over speed Governor, phase failure and phase reversal relay, alarm bell, T. Guide brackets for car and counter weights, rubber padding under winding unit, Motor of
395adequatecapacity, Single reduction worm gear,electro magnetic brake with compression springs, car safety gear, buffer, electro mechanical door locks, tubular S.S hand rail in car. Steel ladder for machine room, Emergency key, motor over load protection devices, final limit switch, position anddirection indicators for car and landing entrances, main suspension ropes, counter weights, lifting joists for mounting the machines S.S. facial plate for car operating panel & landing fixtures, fireman"s switch and other necessary controls, Overload Warning indicator with audio annuouncer, Provision for architraves covering all the three sides up to a Width of 300mm decolam sheet on plywood with TW Frame with aluminium beadings or suitable materials of the existing wall architraves should also cover the thickness of sill level of door frame at the landing and indicator boxes at all landings, full Width half height rear panel mirror complete set
396Supply and installation of 4 loop analogue addressable fire alarm panel, with 16 fire zone indicators, 2 x 40 character backlit LCD, 2 independent sounder circuits,Sound Alarms, Silence/Resound, Mute Buzzer, Accept, Reset buttons, 12 button alpha numeric key pad and 4 cursor keys, Fire, Fault, Test, Disablement, Delayed Mode, Alarms Silenced, Buzzer Muted, Sounders Disabled, Relays Disabled, Power, Supply Fault, CPU Fault, Sounder Fault and Earth Fault indicators, inbuilt battery charger with 2 x 7 AH 12 volts battery. Make: Morley IAS UK/ EQVLT
397Supply and installation of analogue addressable smoke detector photoelectric type with base and led to operate on 24 v dc supply. Make: Morley IAS, UK/ EQVLT
398Supply and installation of addressable electronic sounders 5 watts capacity wall mounting type. Make: Morley, UK/ EQVLT
399Supply and Installation of Addressable manual call points press type, Make: Morley, UK / EQVLT
400Supply & installation of Loop Isolators
401Supply & installation of addressable control module interface units
402SSupply and installation of 2 core x 1.5 sqmm copper Armoured cable fixed on wall or ceiling with clamps, screw.
403Supply of Modvat/ Eqvlt Software for Building Management System integration including Interface units.
404Type: Single Stage. Serial No: JR-SC1/d2 Designation:Single Stage Silver Code Super Conductor Lightning diverter with Golden tipped Receiver, Diffuser, H.T Divider With discharging diverter. PATENT by the GOVERNMENT of INDIA. PATENT No: 385801 Certified by : CPRI [Positive & negative current inpulesshots of 8/20uS wave as per IEC 60099-4 with magnitude of 40kA+10%.
405Supplying and Fixing Mini M.S Tower with strong base plate will be inserted held firmly by strong brackets in place to keep the tower steady against heavy gust of winds with high velocity without affecting the rigidity of the commissioned equipment and all the gaps will be securely filled with silicon paste to avoid any seepage of water and thereby avoid corrosion including Concrete base.
406Test Specification : IS: 2544-1973/ICE -60168-2001. Lightning impulse withstand voltage: (1.1/50u sec. wave) Supplying and Fixing 33 K.V – H.T Insulator including materials.(33KV SOLIDCORE POST INSULATOR / C6-170)
407Supplying and Laying Copper Wire 8 swg (20 sq- mm) for open air network system up to the Earth Cell. (double side earthing) 2 Pair copper down conductors 75+75 = 150 mts each
408Supplying and Fixing 11KV Porcelain Insulator with spike for Open air – net work system. (per product 6nos x 4 set)
409Supplying and Fixing G.I center sturdy pole with holding brakets. (38 mm O/D – B class)
410Supplying and Fixing porcelain wall insulator with PVC pipe, clamps & screws etc.(per product
411Supplying and Digging (Earth cell) and providing earth chemicals, earth discharging units with copper base plate. (Per product 2 earth cell x 4 nos= 8)
412Scaffolding charges
413Civil work – Masonary, concrete with materials and labour charges.
414Supply, Erection, Testing, Commissioning and Handing over of 2Nos ((From Ground Floor to Fifth Floor) (1 no. for UP and 1 no. for DOWN)) PUBLIC SERVICE - LIGHT DUTY SMILE LINE COMMERCIAL ESCALATOR as per following technical specifications including all taxes and duties, Technical Specifications:
4151.STANDARDS : EN 115, 2.STEP WIDTH (MM) : 1000 MM,3.HORIZONTAL STEPS : THREE, 4.VERTICAL RISE : 3900MM, 5.HORIZONTAL SPAN : 12314MM, 6.INCLINATION : 30Degree, 7.SPEED : 0.50M/s, 8.GEAR BOX : WORM GEAR, 9.LIGHTING VOLTAGE : 240v, 10.START : STAR-DELTA, 11.POWER VOLTAGE : 415V, 11.1.FREQUENCY : 50 HZ, 12.ARRANGEMENT : PARALLEL, 13.MOTOR POWER : 5.5 KW, 14.TRUSS : HOT DIP GALVANIZED, 15.DELIVERY IN : WHOLE PIECES, 16.INTERMEDIATE SUPPORT : NOT REQUIRED, 17.INSTALLATION : INDOOR - 18.STANDARD INSTALLATION - 500MM EXTENSION FOR VVVF, 19.TOP : EXTENSION, 20.BOTTOM : STANDARD, 21.HANDRAIL COLOR : BLACK, 22.BALUSTRADE PANEL : TEMPERED SAFETY GLASS (10MM), 23.BALUSTRADE : VERTICAL, SLIMLINE - HIEGHT 1000MM, 23.1.BALUSTRADE PROFILE :HAIRLINE STAINLESS STEEL.
41624.SKIRTING : HAIRLINE STAINLESS STEEL, 25.INNER & OUTER DECKING : HAIRLINE STAINLESS STEEL, 26.FLOAT SWITCH AT LOWER MACHINE ROOM : YES, 27.PANEL OF LANDING PLATE : ETCHED STAINLESS STEEL, 28.OIL-WATER SEPARATOR : YES, 29.STEP : DIE CAST ALIUMINIUM,GREY COLOUR 30.ZINC STEEL DRIVE CHAIN COVER : YES, 31.STEP DEMARCATION : YELLOW DEMARCATION, 32.CHAIN PROTECTION : ZINCED, 33.COMBS : DIE CAST ALUMINIUM, YELLOW PAINTING, 34.STOP BUTTON : YES, 35.BROKEN DRIVE-CHAIN CONTACT : YES, 36.SKIRTING CONTACT : YES, 37.HANDRAIL ENTRANCE CONTACT : YES, 38.BROKEN STEP-CHAIN CONTACT : YES, 39.STEP SAG CONTACT : YES, 40.PHASE MONITOR : YES, 41.ZINC STEEL FLYING WHEEL COVER : YES, 42.MOTOR OVERLOAD AND OVERHEAT CONTACT : YES, 43.COMB CONTACT : YES, 44.STEP GAP ILLUMINATION : YES, 45.MAINTENANCE LOCKING DEVICE : YES, 46.ALARM BUZZER : YES, 47.MOTOR SPEED & ANTI-REVERSAL MONITOR : YES, 48.STEP ANTI-STATIC BRUSH : YES, 49.SAFETY BRAKE ON MAIN SHAFT : YES, 50.HANDRAIL ANTI-STATIC ROLLER : YES, 51.EARTH LEAKAGE CIRCUIT-BREAKER : YES, 52.SERVICE BRAKE RELEASE CONTACT : YES, 53.MECHANICAL ANTI-REVERSAL DEVICE : YES, 54. LED TRAFFIC LIGHT (2) : YES, FIXED ARROW SIGN-ONE EACH AT TOP & BOTTOM.
41755.STEP REVERSING FENCES : YES, 56.TRAFFIC LIGHT : YES, 57.HANDRAIL BROKEN CONTACT : YES, 58.4 DRY CONTACT (UP, DN, ERROR, STOP) : YES, 59.LCD FAULT DISPLAY AT CONTROLLER : YES, 60.FIRE CONTACT : YES, 61.SKIRTING LIGHTING : YES, 62.LED COMB LIGHTING : YES, 63.SKIRTING BRUSH : YES, 64.SKIRTING BRUSH (SINGLE ROW) : YES, 65.STEP MISSING CONTACT : YES, 66.LANDING PLATE SWITCH : YES, 67.AUTO LUBRICATION SYSTEM : YES, 68.AUTO-START : DIFFUSE / RADR SENSOR TYPE, 69.CONTROLLER LIFT DEVICE - ONE SET : YES, 70.MAINTENANCE FENCE - ONE SET : YES, 71.INSPECTION HANDLE - ONE SET : YES, 72.KEY SWITCH : YES, 73.STEP ANTI-UPTHRUST DEVICE : YES, 74.ZINC PLATED STEEL FLYWHEEL COVER : YES, 75.SWITCH BOARD BOX (IP54) : YES, 76.SOFT STOP : YES, 77.LCD FAULT DISPLAY AT MAIN CONTROLLER : YES, 78.ZINC PLATED STEEL DRIVE CHAIN COVER : YES, 79.HANDRAIL SPEED MONITOR : YES, 80.BRAKE LINING SAFETY SWITCH : YES, 81.COMB LIGHTING WITH 30 MIN. UPS : YES, 82.OUTSIDE TRUSS CLADDING : HAIRLINE STAINLESS STEEL ON LEFT, RIGHT & BOTTOM, 83.FREE SERVICE FOR ONE YEAR : YES, 84.ESCALATOR LICENSE : YES. (MR).(Rate 2309322/Per Floor = 2309322*6 =1,38,55,932)
418Supply of Chiller Package units, fully factory built complete with hermetic, Multiple screw  compressor unit(s), Air cooled condenser with copper tubes and Aluminium Fins , insulated evaporator,  integral refrigerant piping and wiring, automatic and safety controls mounted in central control panel and all mounted on a steel frame complete. Motor shall be suitable for 415±10% volts, 50 cycles/second, 3 phase AC supply. The chillers shall be with microprocessor-based control panel with dual incoming point . Compressors type should be Semi hermetically sealed screw with closed transition WYE Delta starter , Disconnect Switch. 1no of Flooded type shell & tube type cooler with copper tubes and CS shell MOC, Multiple compressors and Multiple refrigerant circuit are preferred . 19mm thick nitrile rubber should be provided as cooler insulation Condenser coils should be made of copper tubes with Aluminium fins Chiller should be provided with machine mounted microprocessor-based control panel. Chiller Design Capacity : 400 TR Chiller Entering (inlet) temperature : 12Deg C Chiller Leaving(outlet) temperature : 7Deg C Chilled water Flow : 998 gpm Fouling Factor : 0.0001FPS Ambient temperature : 40Deg C Refrigerant should be R134a AHRI COP: Minimum: 3.0
419Primary Chilled Water Pumpsets Supply, installing, testing & commissioning of Vertical Inline Pumpsets for chilled water circulation. It should be complete with IE-3 TEFC Sq. Cage motor, mechanical seal, rubber bellows for suction & discharge, vibration isolators, etc. The pump shall be suitable for operation through VFD. The pump shall be insulated using 19 mm thickClass "O" Aeroflex / Armacell / K-flex insulation. The pump motors shall be painted with approved colour before handing over. The pumps shall be installed outdoor exposed to weather on terrace. Delivery - 1100 Usgpm Head - 15 m Pump Working Pressure - 10 Kg/cm2 Pump Test Pressure - 15 Kg/cm2 Pump Rating - PN16 Pump Motor - 11 KW
420Supply, installing, testing & commissioning of Closed Expansion Tank with Membrane without insulation valves & fittings, 750 litres, PN16, Safety Valve, PN 16 (1 No. Required per Closed Expansion Tank) 400 mm dia Microbubble Air & Dirt Separator with matching flanges, bolts, nuts & gasket without super vent, insulation, valves & fittings, PN 16, Gas Charging Pipe with Adaptor, Flexair Super Vent Max 3/4" PN10 Pressurization Unit complete with double Pump (2 CMH, 25mWC), IP55 control panel with pressure transmitter, PN 16, zinc chromate primer and 2 coats of synthetic enamel painting.
421Supply, installing, testing & commissioning of the following Double Skin Ceiling Suspended Air HandlingUnits suitable for suspending from the ceiling slab (above the false ceiling) complete with anodized aluminium outlet damper, cooling coil suitable for use with chilled water, MERV-8 Pre-filter, PLUG type fan & motor, integrated VFD, limit switchfor the fan motor section, IE-3 TEFC Squirrel Cage Motor, suspension arrangement complete with bushings of resilient material. The applicable parametersare listed below:
42216 TR Capacity, 3500 Cfm, 0.65 Sqm., 6 rows, 7.5 mmwg, 2.2 KW motor, 1450 rpm to serve Dining-05, FF
423CHILLED WATER PIPE :Supply, Installation, Testing and Commissioning of chilled water pipes Mild steel (Black Steel) class "C" upto 150mm Dia and8mm valve thick for 200mm Dia & aboveas per relevant code cut to required lengths and installed with welded joints providing and fixing all thenecessary fittings like bends, elbows, tees, reducers, vibration isolators, hangers, supports, etc., & as per specification. Galvanised steel hangers or floor supports as required, all fittings & flanges as required, Painting of supports and pipes with red oxide primer coating, With end nipples to remove all dirt from the system, Pressure testing, Making openings in walls and finishing with suitable fire seal, Providing fire seal in openings made in structural beams & walls and in shafts. MS ERW BLACK PIPE CONF TO IS: 1239 / 3589 GR 410 in random length of 5 to 7 Mtrs
42425 mm dia
42532 mm dia
42640 mm dia
42750 mm dia
42865 mm dia
42980 mm dia
430100 mm dia
431125 mm dia
432150 mm dia
433200 mm dia
434250 mm dia
435300 mm dia
436Supply and Fixing of Chilled water pipe insulation using EPS TF quality of thickness 50 mm for pipe below 250 mm dia & 75 mm dia for pipes above 250 mm dia having density of 32 kg / m³ with Vaopur Barrier, wire mesh with 2 coats of enamel paint and the arrangement surrounded by 26G Al. Cladding
43725 mm dia
43832 mm dia
43940 mm dia
44050 mm dia
44165 mm dia
44280 mm dia
443100 mm dia
444125 mm dia
445150 mm dia
446200 mm dia
447250 mm dia
448300 mm dia
449Supply , installation , testing and commissioning of insulated cast iron extended stem type Butterfly Isolation Valves with Insulation complete with gaskets , flangers etc.,PN10 class rating IS 210 Grfg 260body, Ductile iron ASTM A 536 Gr 65-45-12 Disc, EPDM / Buna -M,SS316 body seal.
45025 mm dia - Ball Valve
45132 mm dia - Ball Valve
45240 mm dia - Ball Valve
45350 mm dia
45465 mm dia
45580 mm dia
456100 mm dia
457125 mm dia
458150 mm dia
459200 mm dia
460250 mm dia
461Supply, Installation, Testing & Commisioning of Mechanical Panel (Valve Package) PUF Density (48Kg/m3) 50mm Thick Puf with Density of 48kg/cu.m with Aluminium laminated on both sides with 160gpm assembled as a box around the valve package system. In a rectangle or square form with double rebate seating & joineries with silicon non-settling high viscous sealent. Joineries on the outer surface covered with 3mm closed cell nitrile rubber covered further with 24G GI sheets on the corner edges and middle part. All together ensure the zero leak on external air into the preinsulated box wrapped and held tight with packing strips. The whole valve packagemust be factory assembled pre tested and painted with +100gsm of silicon paint. The air gap to be filled with 3mm thermacoal balls. The whole of pre assembled valve package along with box should be pre assembled with a frame stucture to be kept on the floor along with flanges + mating flanges with 2" of extended required pipe with chamfered well preparation with end cap cover on both sides. Valve package includes 2 Nos of Isolation valve, One High Rangeability 2 way control valve as per above valve specification, Drain valve connection & Port for Pressure gauge and thermowell on Both sides.
462F 100 mm
463F 65 mm
464F 50 mm
465Supply , installation , testing and commissioning of cast iron Motorised Butterfly Isolation Valves without Insulation complete with gaskets , flangers etc.,ASA 150# rating, PN10 class rating IS 210 Grfg 260body, Ductile iron ASTM A 536 Gr 65-45-12 Disc, EPDM / Buna -M,SS316 body seal/
466150 mm dia
467200 mm dia
468Supply , installation , testing and commissioning of insulated y type with fabricated steel body strainer complete with flanges , bolts , nuts , gaskets etc., with mesh less than 20, 1.6mm thick screen , CI 210 FG 260 body, with PN 10.0 rating ,SS304 filter /w
46980 mm dia
470150 mm dia
471Supply , installation , testing and commissioning of insulated Non Return Valve complete with flanges , bolts , nuts , gaskets etc., with 10.0 rating /relevant code / equiv . Swing check type , IS 210 Gr FG 260 body ,IS 210 Gr FG 260 Disc,13% Cr SS Discs
472150 mm dia
473200 mm dia
474Supply ,Installation , testing and commissioning of insulated and gun metal screwed type High Rangeability Control valve with control panel, cables etc., complete with Transformer, linkage mechanism, modutrolmotor, cables, insulation etc., & as per specification .sizes upto 80mm dia confirming to BS:5154/equiv. and cast iron flanged type confirmed to BS:1452/equiv.for sizes 100mm & above complete.
47532 mm dia
47640 mm dia
477Thermometers- Dial Type - 4" Dia (ALL SS TYPE) Thermometers of approved make & shall be of mercury in steel type with range suitable for the temperature services.It should be installed in the thermowells as explained in the tender specifications. Syphons and cocks to be provided along with SS snubber.
478Supply & Installation of Test Points
479Pressure guages shall be of Bourdon (100 mm) type with range selected so that normal operation is near to middle of the scale.Syphons and cocks to be provided along with SS snubber.
480Supply , installation , testing and commissioning of Ball Valve for Drain
48125 mm dia - Ball Valve
48250 mm dia - Ball Valve
483Supply & Installation, testing and commissioningof 3/8" Air Purge valves with Ball Valve
484Supply , installation, testing and comissioningof Bellows
485125 mm dia
486150 mm dia
487Supply ,Installation , testing and commissioning of insulated Electronic Flow meter with feedback provision to the BMS to control minimum flow across the chiller.
488F 150 mm
489F 200 mm
490Supply, Installation, testing and Commisioning of 25mm thick Puf Insulated drain piping GI screwed pipes from AHU drain pans, chilled water pump glands to nearest floor drain, complete with U - trap and necessary fittings ( 25 mmPuf and 26G Al.Cladding).
491F 25 mm
492F 50 mm
493F 100 mm
494F 150 mm
495Supply, Installation, Testing and Commissioningin position the following manual balancing valves: Supply, Installation, Testing & Commisioning forInsulated and Gun metalscrewed type balancing valves for sizes upto 80 mm dia. confirming to BS: 5154 / equiv. and Cast iron flanged type confirmed to BS:1452 / equiv. for sizes 100 mm & above complete with matching flanges, bolts, nuts and gaskets,etc., & as per specification. PN 10 class rating,
496150 mm dia
497200 mm dia
498Supply ,Installation testing & commissioning of a Air &Dirt Separators (PN-10) as per Specifications on the chilled water line located at the pump suction and suitable for water flow as per drawings.The separator should be complete with antirust coating, service valve, non return valve, butterflyvalve connection for makeup water inlet, flanges, drain valve etc. Over Flow Rate : 1272 US gpm, Line Size : 250 mm
499Supply ,Installation testing & commissioning of a Air &Dirt Separators (PN-10) as per Specifications on the chilled water line located at the pump suction and suitable for water flow as per drawings.The separator should be complete with antirust coating, service valve, non return valve, butterflyvalve connection for makeup water inlet, flanges, drain valve etc.
500Over Flow Rate : 480 US gpm, Line Size : 150 mm
501All ducting shall be of factory fabricated finished duct only.All sheet shall be Class VIII – light coating of zinc, nominal 120 gm / sqmt surface area and Lock Forming Quality prime material along with mill test certificates. If required, the vendor should carryout the duct leak testing to ensure that the duct leakage is not exceeding 3.0% of the total air quantity as per SMACNA, leakage class 12. Quantity is based on single duct fabricated length shall not exceed 1200mm. The Duct to be manufactured as per SMACNA standard for Class-500pascals. Make of Material : Tata / Jindal
50224G. Ducting
50322G. Ducting
50420G. Ducting
505Double skin plenum 25mm thick 1.2 mm extruded Aluminium profiles filled with 25 mm thick PUF of Min 40 Kg/m3 and material of construction of 0.6mm precoated/GI sheetexterior skin andinner with 0.6mm thick Galvanized 120 GSM provided with inlet and outlet openings made of 2mm Min thick Extruded Aluminium collars with closed cell gaskets.
506Supply and fixing of Acoustic insulation of ducts with Class "1"open cell, elastomeric, nitrile rubber, dust free, fiber free, and CFC free insulation with 140-160 kg/cu.mtr density as per specification. Make : Armasound/Aeroflex 15 mm thick
507Thermal insulation of the sheet metal duct with closed cell Nitrile RubberMake :Armacell/Aeroflex/Aerofoam 9mm thick
508The volume control damper shall be of low leakage type with the outer shell constructed of 1.6mm thick galvanized steel frame and the blade/Leaf with 1.6mm thick GSS. And with necessary flanges for connection etc., as per specification.
509FIRE DAMPER WITH OPPOSED BLADE - Extended Sleeve type The Fire damper as per UL 555, constructed the outer shell with 1.6mm thick galvanized steel frameand the blade/Leaf with 1.6mm thick GSS. And with necessary flanges for connection as per specifications and drawings.
510with Fusible Link & spring mechanism, The damper shall be held open by a replaceable fusible link rated at 74degC.
511The volume control damper with the outer shell constructed of 1.6mm thick galvanized steel frame and the blade/Leaf with 1mm thick aluminum. And with necessary flanges for connection and as per specifications.
512Higher grade Aluminum Extruded powder coated supply/Return air linear / continuous grills Size 6" height. ( angle of throw as per the shop drawing )The Stud of the Grill need to be Powder Coated with Black Colour
513The collar damper shall be constructed out of extruded aluminum alloy with multiple blade of oppose blade type. Shall be used for the Supply air diffuser & grilles as per the drawings & specifications. The vertical stem should be in block color.
514All dampers should of robust construction with multi opposed blade construction of low leakage type. The outer casing shall be made out of 1.6mm.thick GI welded frame with flat type 1.6mm. GI sheet blade with galvanized steel spindle, provided with bronze bushes, suitable links, levers and quadrant, handle as required for their proper operation, control or setting to any desired position, flanges to connect to the equipment / duct.Dampers and their operating devices shall be made robust, easily operable.Every damper shall have clear indication showing the damper position at all the times
515The Non vision louver shall be constructed with high grade aluminum alloy sections with necessary flanges. The louver shall be of powder coated finish.
516Flexible double layer canvas connection of at least 150 mm width shall be provided between AHU mouth & plenum. This canvas connection shall contain a provision (zip) for measuring the DBT and WBT of the cooled and dehumidified air.
517Supply, erection, testing, commissioning and handing over of 1No 500 KVA Diesel Generator set of 0.8 P.F. Three Phase 415/420 Volts, 50 C/S, 1500 RPM as detailed below. 1. ENGINE Water cooled diesel engine suitable for Generator Application with a shaft output of 600 BHP at 1500 RPM under NTP condition as per BSS 5514/IS 10000. The Engine shall comprise the following Standard scope of supply. (Make:Kirloskar/Cummins/AshokLeyland/ Greaves) 1. Dry type Air cleaner 2. Expansion bellow 3. Radiator, Radiator fan and mounting 4. Air to Air charge cooler 5. Exhaust Gas turbo charger 6. Lube oil cooler and Lube oil filter 7. Fuel filter (pre and micro) 8. In-Line Mono-block fuel injection pump with governor fuelfeed pump 9. Electronic governor 10.24V Battery charging alternator 11. 24V Volt electric starter motor 12. Engine test certificate 13. Residential muffler. 14. Fly wheel with starter ring ENGINE INSTRUMENT PANEL MOUNTED Engine control panel consisting ofON /OFF /STARTKey Lube oil pressuregauge, Oil Temp gauge, High water temperature gauge andelectronic hour meter and RPM indicator. SAFETY SYSTEM OF ENGINE: The Engine shall trip for the following conditions with visual alarm device. 1. Low Lubricating Oil pressure 2. High Water temperature 3. Vee-belt failure and over speed,
518The visual indicator should also be provide for low battery indication. The Engine should be capable of providing 10%over load for one hour for every 11 hours continuous running at full load 2. ALTERNATOR:Alternator capacity of 500 KVA/400 KW, AC 3 Phase, 50HZ,415/420 Volts, 0.8 P.F. 4 wire self excited, selfregulated designed to run at 1500 RPM under NTP conditions conforming to BS 5000 /IS 13364 (Part-II) 1992 to be coupled directly to the Diesel Engine and Test certificate. (Make: Kirloskar/ Crompton/ Greaves /Equivalent). 3.AMF Control Panel:The AMF control panel (Cubical) should be fabricated with Vermin proof and dust proof best Quality sheet steel and floor mounted with removable rear panels and hinged front doors with enamel paint and incorporating the following with suitable provision for connecting incoming and outgoing leads having been made on the control panel.1. 1 No Ammeter selector switch 2. 1No AC Voltmeter 3. 1No Voltmeter Selector switch 4. 1No AC Voltmeter 5. 3Nos Current transformers with suitable ratio 6. 1No Frequency Meter 7. 1No KWH Meter 8. 1No Power factor Meter 9. 1No KW Meter 10. Battery charging set comprising of the following for charging the battery from mains. a. Transformer/ Rectifier b. DC Ammeter c. DC Voltmeter d. ON/OFF Switch. e. Charging rate selector switch f. Circuit breaker g. Voltage Regulator
519NOTE: This will be in addition to the battery charging Alternator fitted to the Engine 11.1 Set Air break contactor with auxiliary neutral contactor for main supply 12. 1 Set Low voltage HRC fuse for the short circuit protection of the main supply 13. 1 Set Alternator contactor with auxiliary neutral contactor 14. 1 Set three pole bimetal release for over load protection of alternator 15. 1 Set low voltage HRC fuse for the short circuit protection of the alternator 16. 1 Set DC control relays incorporating engine start stop and failure to start/Lockout 17. 1 Set Selector switch auto/ manual 18. 1 No Push button “Start” 19. 1 No Push button ”Stop” 20. 1 No Push button ”Reset” 21. 1 No Signal lamp for indicating load on mains 22. 1 No Signal lamp for indicating load on set 23. 1 No Signal lamp for indicating set fails to start 24. 1 No Signal lamp for indicating set running 25. 1 No Signal lamp for indicating Battery charger ON 26. 1 Set Pilot lamps of 3 Nos 27. MCCB of 800 A capacity with magnetic thermal over lead release, instant short circuit trip and under voltage release switch 28. Rectangular copper bus bars (1 No for each phase, neutral and earthing terminal) of adequate capacity duly colour coded with heat shrinkable PVC sleeves. 29. 1 No Mains Voltage monitor 30. Hooter/ Audio Alarm for indication set fails to start and for DG O/L 31. 1 Set Timers 32. Audio and visual indication arrangements for a. Low Lubricating Oil pressure b. High water temperature c. Over speed 33. 1 No Earth fault relay 34. Isolator to Isolate the neutral
520NOTE: 1. The control panel should be complete with necessary fuses, cables, labels, other accessories with isolation arrangements. 2. The engine should trip for the following conditions a. Low Lubricating Oil pressure b. High water temperature c. Over speed 4.ACOUSTIC ENCLOSURE: Acoustic enclosure shall be powder coated and Fabricated of 16 SWG CRCA MS sheet. The silent canopy shall be of nut bolt type construction. Critical processes of punching are done on CNC Machines to maintain dimensional accuracy of hole within 0.1 mm. Powder coating done after seven-tank surface preparation process of sheet metal. Canopy panel and doors shall have inside lining of FIRE RETARDANT 64Kg/m density Mineral wool of 100mm Thickness as acoustic material. Four hinged doors shall be provided to canopy. The average sound level at 1Mt. distance shall be as per latest CPCB norms. Surface Treatment – Painting: The enclosure surface shall be suitably treated for degreasing de-rusting and posphating. The canopies are passed through seven- tank treatment thoroughly. Additional features of Canopies: Canopy fabricated on CNC machines with dimensional Accuracy of 0.1mm so as to increase its durability. Special designed supporting rips/ structures are used in canopies so as to be sturdy steadiness and to reduce the vibrations of the DG sets if any. World class Cooling Package: Canopies shall have Cooling package for which it can also perform at 45° deg C/ ambient temperature No grouting required on the ground only a level surface capable of withstanding the DG weight.
521Lifting hooks shall be provided for the acoustic Enclosure, which should be unloaded independently of the DG Set. The Gen set frame shall also be provided with hooks for unloading. Temperature rise inside the canopy Canopies shall be designed so as to maintain the temperature difference between ambient and air inlet at cleaner within the enclosure well within 5-7 deg centigrade as per the latest norms. 5.FUEL TANK: 300Ltrs. Removable fuel tank shall be fabricated out of 14SWG CRCA MS sheet and is part of base frame. It is duty painted and fitted with inlet and outlet connections and mechanical fuel gauge. Fuel tank can be easily removed for clearing or any maintenance. 6.BASE FRAME: Base frame should be fabricated in sheet metal. The base frame is rugged in construction and designed for mounting engine and brush less alternator closely coupled with cross members mounted on AVM. The base frame shall be provision for mounting of acoustic enclosure on it. The supply of generator set includes loading unloading and transportation charges. 7.BATTERY: 2Nos 12V 180AHR Battery. (Data-38)
522Construction of a suitable concrete foundation with cement concrete 1:2:4 with sand cushion all around the foundation erection of 500KVA Generator set over the foundation and with proper alignment over the existing foundation of suite 500 KVA Gen set.
523Supply and installation of exhaust piping of sufficient length with suitable MS pipes so as to extend outside the generator room with necessary thermal insulation.
524Supply of lubricating oil and first charging of starting battery and supply of 300lts diesel to run the Gen set for minimum of 8 hours.
525Supply, fixing and termination of RJ 45 with face plate and back box for LAN. Make:D-Link/Eq.
526Supply and fixing of 24 port 10/100/1000 Mbps layer -3 fully managed fibre portswitch. Make: D-Link/Eq.
527Supply and fixing of 24 port 10/100/1000 Mbps layer -2 fully managed switch. Make: D-Link/Eq.
528Supply and fixing of 24 port fully loaded patch panel. Make: D-Link/Eq.
529Supply and Installationof 1m length patch cord. Make:D-Link/Eq.
530Supply and Installationof 2m length patch cord. Make:D-Link/Eq.
531Supply and laying of Cat6 cable in existing PVC pipe on wall and ceiling for LAN and CCTV.Make:D-link/eq.
532Supply and installation of 6U wall rack with power managerandall accessories.
533Supply and laying of 1" PVC pipeon wall and ceiling. (Speaker+CCTV+LAN)
534Supply and Installation of 4 MP IP Indoor / outdoorbullet/domeCamera,120 db WDR, 6 mm Fixed lens. Make:Hikvision/Eq.
535Supply and Installation of 8-port poE switch, which supports IEEE802.3 af/at poE standard. Make: D-link/Eq.
536Supply and installation of32channel Network Video recorder , band widthsupport 2 SATA HDDs up to 8 TB . Make :Hikvision/Eq.
537Supply and Installation of8TB built inHard Disc Drive.Make: Seagate/Eq.
538Supply and Installation of 43 inch HD smart LED TV for CCTV monitor. Make:Sony/Eq.
539Supply and installation of 4U wall rack with power managerandall accessories.
540Supply and Installation of 15 W High fidelity2-Way ceiling speaker with 100V. Make:Bosch/Eq.
541Supply and Installation of 15 W High fidelity2-Way wall speaker with 100V. Make:Bosch/Eq.
542Supply and run of 2 core 1.5 Sq.mm Loudspeaker cable with PVC pipe.Make:Orbit/Eq.
543Supply and Installation of 240W amplifier with 6 Mic,2 Aux Inputs Preamplifier, line output for connecting to a booster amplifier and for recording the programme.Make:Bosch/Eq.
544Supply and Installation of2 KVA Servo Voltage Stabilizer with No Waveform Distortion,Less than 1 sec Stabilization Time,Voltmeter displays output voltage,specifically designed for audio equipment. Make:Studiomaster Model No:SVC 1000
545Supply and Installation of 32 U heavy duty audio rack with 10 tray,power sockets, lock and key facilities.Make:Valrack/Eq.
546Supply and Installation of Voice Alarm Controller LED power meter,13 system fault LEDs, Two fault state buttons, Two emergency state buttons, Six EMG zone status LED pairs, Six EMG zone select buttons, Six BGM zone select LEDs, Six BGM zone select buttons,Six BGM zone volume control knobs, Two BGM source status LEDs, Three knobs for BGM volume, Treble, and bass levels, All-call button, Indicator test button, EMG state button , Alert message button,Make :Bosch LBB 1990/00
547Supply and Installation of 6 Zone Plena Voice Alarm Router is an expansion unit that can add six zones and 12 input , 12 loudspeaker outputs,Two external amp inputs Call output, Six volume override outputs, 12 trigger inputs, RS-232 connector, Two system interlinks, Two external amp outputs (XLR/balanced),inputs and outputs for one or two amplifiers muti-amplifier one or two-channel system.Make :Bosch / LBB 1992/00
548Supply and Installation ofVoice Alarm 6 Zone Call Station, Controls and indicators, PTT-key, PTT status LED, Six zone selection keys, Six zone selection LEDs , All-call key, All-call status LED, Eight DIP switches, RJ45 connector, 24 VDC input,Keypad connector Make :Bosch/ LBB 1956/00
549Supply ofCall Station Keypad , Seven zone selection keys, LED indications for zone selection, Up to eight keypads,Two RJ45 jacks, 24 VDC input, Keypad connector Make : Bosch LBB1957/00
550Supply and laying of 6 core outdoor OFC cable in existing HDPE pipe in ground. Make:D-link/eq.
551Supply and Installation of media converter with OFCconnecors and connecting cables including splicing charges. Make:D-Link/Eq.
552Testing and commissioning of LAN network system,CCTV security camera system,Voice alarm system with other necessary accessories including demo andtraining to the occupying department.
553TNEB Demand Charges for 1000KVA
554GST at 18%