Tender For Repair Maintenance Of Internal Electrical Fitting Fixtures And Em Works At Brookshabad Arsr Building Under Ge Brichgunj, South Andamans-Andaman And Nicobar Islands

Military Engineer Services-MES has published Tender For Repair Maintenance Of Internal Electrical Fitting Fixtures And Em Works At Brookshabad Arsr Building Under Ge Brichgunj. Submission Date for this Tender is 17-05-2024. Electrical Products Tenders in South Andamans Andaman And Nicobar Islands. Bidders can get complete Tender details and download the document.




Tender Notice

43249294
Tender For Repair Maintenance Of Internal Electrical Fitting Fixtures And Em Works At Brookshabad Arsr Building Under Ge Brichgunj
Open Tender
Indian
Andaman And Nicobar Islands
South Andamans
17-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Repair Maintenance Of Internal Electrical Fitting Fixtures And Em Works At Brookshabad Arsr Building Under Ge Brichgunj

Key Value

Document Fees
INR 500 /-
EMD
INR 60000.0 /-
Tender Value
INR 30 Lakhs /-

Attachment

FileName File Description File Size
d7e3ff7c-d4c9-4066-b997-10d4ed78e8ab.html Tender Notice 0 KB
8470Atenderdoc.pdf Tender Document 0 KB
BOQ_729044.xls Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work:REPAIR & MAINT OF INTERNAL ELECTRICAL FITTING & FIXTURES AND E/M WORKS AT BROOKSHABAD & ARSR BUILDING UNDER GE BRICHGUNJ.
Sl. No. Item Description
1Taking down carefully, copper/aluminium point wiring (Light, fan, scoket or power) complete, including fittings and fixtures such as switches, ceiling roses, regulators, sockets etc., and making good disturbed surfaces of walls floors, etc., complete all as specified and as directed.
2M&L Point wiring complete with 1.5 sqmm single coreFRLS PVC insulated andunsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVC casing and capingand all accessories fixed to walls / roofs / ceiling etc. and including1.5 sqmm copper cableFRLS PVC insulated andunsheathed cable 1100 volts as earth continuity conductor and connected to common earth dolly for One light point/Bell pointcontrolled by one switch, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover/Pre moulded PVC switch board for housing the switches, socket outlets, fan regulators etc., all as specified and as directed.
3All as pere item Sl No 2.00 above but One fan point controlled by one switch and one regulator
4All as pere item Sl No 2.00 above but One 3 pin switch socket outlet point 5 amps on same board with other switches.
5All as pere item Sl No 2.00 above but One 3 pin switch socket outlet point 5 amps on independent board.
6M&L for point wiring with 4 Sqmm FRLS PVC insulated and unsheathed single core stranded copper conductor cable 1100 volts in PVC casing & caping for 2 in one, 3 pin 5 Amps & 15 Amps multi purpose socket on independent board and existing cast iron or pressed steel terminal box with new laminated sheet top cover 3 mm thick, including PVC insulated & unsheathed copper conductor cable 4 SqmmFRLS PVC insulated andunsheathed cable 1100 voltssize for earth continuity conductor and connected to earth dolly including painting to existing sunken boxes with anticorrosive bituminous paint after through cleaning complete all as specified and directed.
7M&L for point wiring as per colour coding with 1.5 sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 19 mm thick rigid non metallic PVC concealed conduit medium quality including new sunken terminal boxes duly epoxy painted and 3mm thick plastic laminated sheet top cover and continuity earth wire PVC insulated copper conductor standard unsheathed of size forOne light point/Bell pointcontrolled by one switch 1.5sqmmincluding Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills sunshades, shelves, lintels, etc.; and cutting chases forconcealed conduit wiring,etc., and making good, cutting not exc 10 cm girth in brick wall. complete all as specified and as directed.
8All as per item Sl No 4.00 above but One fan point controlled by one switch and one regulator
9All as per item Sl No 4.00 above but One 3 pin switch socket outlet point 5 amps on same board with other switches.
10All as per item Sl No 4.00 above but One light point controlled by two two way switch.
11All as per item Sl No 4.00 above but One 3 pin switch socket outlet point 5 amps on independent board.
12All as per itemSl No 4.00 above but with copper conductor cable for one 3 pin socket outlet, 15 amps independent, with cable 4 Sqmm size and 4 Sqmm earth continuty conductor, complete all as specified and as directed.
13M&L for point wiring with 1.5 Sqmm FRLS PVC insulated single core stranded copper conductor unsheathed cable in the existing PVC concealed conduit/ surface conduit including fittings and accessories complete with PVC insulated copper conductor earth wire 1.5 Sqmm for one light/ one bell/ fan point through regulator point controlled by one switch in old/ existing cast iron/ pressed steel terminal boxes but with new 3 mm thick plastic laminated sheet top cover, painting existing sunken boxes with anticorrosive bituminous paint after thorough cleaning complete all as specified and directed.
14All as per Srl item No. 6.00 here in before but for 2/3 pin socket outlet 5 Amps multi purpose on independent board including continuous earth wire PVC insulated unsheathed copper conductor 1.5 Sqmm and connected to earth dolly, complete all as specified and directed.
15All as per srl item No. 6.00 here in before but for 2/3 pin socket outlet 5 Amps on the same board complete all as specified and directed
16M&L for point wiring with 4 Sqmm FRLS PVC insulated and unsheathed single core stranded copper conductor cable in existing PVC concealed conduit/Surface conduit for 2 in one, 3 pin 5 Amps & 15 Amps multi purpose socket on independent board and existing cast iron or pressed steel terminal box with new laminated sheet top cover 3 mm thick, including PVC insulated & unsheathed copper conductor cable 4 Sqmm size for earth continuity conductor and connected to earth dolly including painting to existing sunken boxes with anticorrosive bituminous paint after through cleaning, all as specified and directed.
17S&F switch piano flush type single pole one way 5 amps, complete all asspecified and as directed.
18S&F switch piano flush type single pole one way 15 amps, complete all asspecified and as directed.
19S&F switch socket combination 2 in 1, 3 pin (mult pin) 5 amps flush/box type, complete all as specified and as directed.
20S&F switch socket combination 2 in 1, 5 and 15 amps flush/box type, complete all as specified and as directed
21S&F ceiling rose surface baklite 65 x 50 mm 3 terminal, complete all as specfified and as directed.
22S&F lamp holder PVC body with back plate suitable for batten fittings, complete all as specified and as directed
23S&F bell push single phase, 240 Volts, 50 Hz, complete all as specified and as directed
24S&Fswitch piano flush type single pole two way 5 amps, complete all asspecified and as directed
25S&F fan speed regulator, electronic suitable for single phase AC, 240 volts, 50 Hz,100 watts, complete all as specified and as directed
26S&Fbell Ding Dong 240 Volts 50 Hz complete all as specified and directed.
27S&F Modular switch 1 way 5 A, 1 module all as specified and directed.
28S&F Modular switch 1 way 15 A, 1 module all as specified and directed.
29S&F Modular Bell push 5A, 1 module all as specified and directed.
30S&F modular socket outlet, 2/3 pin combined , 6 Amps, 2 module, 230 volts all as specified and directed.
31S&F modular socket outlet, 2/3 pin combined , 6/16 Amps, 2 module, 230 volts all as specified and directed.
32S&F modular fan step regulator, 230 V, AC, 120W - 2 module complete all as directed.
33S&F in repair metal enclosure distribution board SPN, 12way 240 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs, including taking down old MCB/DB, complete all as as specified and as directed by Engineer-in-Charge Note:- Incoming & Outgoing connections from the DB shall be provided with proper lugs/thimbles etc.
34All as per item Sr No 24.00 above butdistribution board SPN, 8 way 240 volts complete all as specified and directed.
35All as per item Sr No 24.00 above butdistribution board SPN, 4 way 240 volts complete all as specified and directed.
36All as per item Sr No 24.00 above butdistribution board SPN, 2 way 240 volts complete all as specified and directed.
37S&F sheet metal enclosures Loadline vertical distribution board TPN, 4 ways 415 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs and in and including 63A MCCB ,16KA as incomming complete all as specified and as directed including taking down old MCB DBs completeincluding cutting chases pinning in making good to facings where required and pointing in cement mortar 1:3 ends of edges of landing,steps, cills sunsades,shelves,lintels,etc and cutting for concealed conduit wiring etc and making good,cutting not exc 10 cm girth in brick wall complete all as specified.
38S&F in repair MCB single pole and neutral, 240 volts, 40 amps,10KA,230V, B series complete all as specified and as directed.
39S&F in repair MCB single pole 240 volts, 5 to 32 amps,10KA,B series ,230v complete all as specified
40S & F in repairs Single Pole and Neutral Enclosure with Two Pin Earth Plug and Socket complete with one MCB, SP, 20 Amps, 240 Voltsall as specified and as directed.
41M & Lin repairs for sub main wiring complete with two runs of 6 Sqmm FRLS single core PVC insulated unsheathed single core cable 1100 volts grade, multistranded with copper conductor (ISI Marked) drawn through and including PVC Casing and caping and all accessoriesfixed to wall/ roofs/ floors etc with one run of 6 sqmm FRLSsingle core multistranded copper conductor as earth continuity conductor, including dismantling unserviceable sub main wiring including accessories,complete all as specified and as directed by Engineer-in-Charge. Note : (1) Two runs of cable one run of conduit & one run of earth continuity conductor shall be measured as one running metre.
42All as per above item Sr No 29.00 but of size 4 sqmm complete all as specified and as directed.
43All as per above item Sr No 29.00but sub main wiring of size 2.5 sqmm complete all as specified and as directed.
44M & Lin repairs for circuit wiring complete with two runs of 1.5 Sqmm FRLS single core PVC insulated unsheathed single core cable 1100 volts grade, multistranded with copper conductor (ISI Marked) drawn through and including PVC Casing and caping and all accessoriesfixed to wall/ roofs/ floors etc with one run of 1.5 sqmm FRLSsingle core multistranded copper conductor as earth continuity conductor, including dismantling unserviceable sub main wiring including accessories,complete all as specified and as directed by Engineer-in-Charge. Note : (1) Two runs of cable one run of conduit & one run of earth continuity conductor shall be measured as one running metre.
45S&F in repair PVC Casing caping/Conduit Pipe of size 25 mm with accessories like PVC saddles, bend,Tees,Elbow and screws etc.
46All as per item Sr No 31.00 above but conduit pipe of size 20 mm dia complete all as specified.
47S & F in repairs Heavy duty PVC Domestic Surface type for Switches of following sizes (a) 1 Gang Box
482 Gang Box
493 Gang Box
504 Gang Box
515 Gang Box
526 Gang Box
537 Gang Box
54S&F energy efficient LED batten 22W with aluminum housing 4ft in length nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours includinglamp and connecting with twin core shethed cable from fitting to ceiling rose all as specified and as diected.
55S & FLED mirror light fitting 1 x 10 Wattprovided with high output diffuser including high efficiency electronic driver complete with LED lamp, prewired upto connection block and connecting with three core PVC copper flexible cable of size 1.5 Sq.mm from ceiling rose to connector block, including taking down old unserviceable mirror light fitting of any wattage, complete all as specified and directed by Engineer-in-Charge.
56S&F Star surface mounted LED 12 w Round type within die cast aluminium housing finished in premimum white powder coating prewired upto connection block and connecting with three core PVC copper flexible cable of size 1.5 Sq.mm from ceiling rose to connector block, including taking down old unserviceablefitting of any wattage, complete all as specified and directed.
57S&F in replacement of LED Bldg security light fitting 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including necessary brackets (made out of 25 mm bore GI light grade pipe approx. 0.6 M long) nuts, bolts etc to be fixed as on walls complete as directed.
58Dismantling the burnt out old winding wire complete and cleaning the internal slots of rotor with ring and rewinding with new rotor shaft the ceiling fan of size 1200mm/1400mm sweep motor with super enamelled copper winding wire of suitable SWG including varnishing, baking in oven and reassemling complete all as specified and as directed.
59S&F in repalcement canopy of ceiling fan, complete all as specified and as directed.
60S&F in repalcement ceiling fan hanging clamp with bush, locking pin and nut and bolt, complete all as specified and as directed.
61Dismantling and taking down ceiling fan of any size/sweep from existing position complete with blades, down rod and canopy etcand servicing the same properly by cleaning, greasing, oiling replacing the unservicable spare parts etc, and reassembling and refixing in the same position all as specified and as directed. (Note: cost of spare parts shall be measured and paid separately as supplied only. The cost of labour for replacement of spare parts deemed to be included under this item)
62S&F ball bearing suitable for ceiling fan of any sweep and make complete all as specified and as directed.
63S&F down rod of appropriate sizesuitable for ceiling fan of any sweep and make complete all as specified and as directed.
64Supply and replace in repairs fan condenser 2.5 mfd, AC 440 volts, 50 Hz complete all as specified and as directed.
65Taking out and dismantling the burnt out old winding wire complete and cleaning the internal slots of rotor with ring and rewinding the exhaust fan of size 250 to 300mm sweep motor with super enamelled copper winding wire of suitable SWG including varnishing, baking in oven and reassemling refixing at same/ required location, complete all as specified
66All as per item No48.00 above but PVC Ventilation fan 180 to 200 mm sweep complete all as specified and directed.
67S&F and testing of air ventilating fan of size 250 mm , 230V AC complete all as specified and directed.
68S&F in repairs condensor 4/3.5 mfd, AC 230 volts, 50 Cycles, complete all as specified and directed.
69S&F in repairs ball bearing suitable for exhaust fan of any sweep and make complete all as specified and as directed
70Taking down exhaust fan of any size/sweep from existing position complete with blades from brackets etc and servicing the same properly by cleaning, greasing, oiling replacing the unservicable spare parts etc, and reassembling and refixing in the same position complete all as specified and directed. (Note: cost of spare parts shall be measured and paid separately as supplied only. The cost of labour for replacement of spare parts deemed to be included under this item)
71Material & labour, earthing complete with galvanize steel earth plate electrode 60 cms x 60 cms x6.00mm thick buried directly in ground vertically to a depth not less than 2.25 meter below ground level with top edge of the plate not less than 1.5 metre below normal ground level connected togalvanised earth lead wire 4.0mm by means of bolts ,nuts ,check nuts and washers of galvanized iron or steel and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron or steel pipe light grade 40 mm bore and water pipe 20 mm bore GI light grade (ISI marked ) with funnel and wire mesh ,including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No, 5 of MES Sch Part-1 (2009), complete all as specified and directed.
72S&F in replacement of PVC ventilating fan 200 mm sweep complete all as specified and directed.
73Taking down and refixingof unserviceable bolt of existing geyser, M&L grouting of new bolt (tee type) at new place and refixing of geyser of any type and any capacity all as speified and directedby Engr in Charge.
74M&L Taking down and refixing of electric water heater (Geyser) of any capacity for carry out necessary repair on it all as specified and directed. For Maintenance of storage type electric water heater (Geyser )of any capacity comprising of the following activities. (a) Inspection taking down, opening, dismantling, descaling, brushing and cleaning of storage tank and examining of water tightness of storage tank after cleaning and descaling. (b) Check and connect Earth continuity of electric items. (c) Checking and adjustment of pressure release valves. (d) Check maintenance and refix thermostat and its functioning. (e) Checking of dead weight, cleaning and seal and ensuring that vent hole is not blocked . (f) Visual examination of fusible plug.
75S&F in repairs Heating element of 1500 watts, 240 volts suitable for existing complete all as specified and as directed.
76S&F in repairs Thermostat element suitable for 25 ltrs capacity water heater, suitable for existing complete all as specified and as directed.
77S&F in repairs Geyser "Hot & Cold" PVC pipe line connecting to stop cock off 15mm dia, 450mm length all as specified and as directed.
78S&F scotch screw 10mm for installation of water heater
79S&F neon bulb red and green in colour forindication of water heater
80S&F top cover of water heater
81Supply only bottom cover of water heater
82S&F LED lamp 9W, 230 Volt complete all as specified and directed.
83Supply and fix 10 w LED decorative light and connecting with PVC copper flexible cable of suitable size, including taking down old unserviceable fitting of any wattage, complete all as specified and directed
84Excavation in trenches not exceeding 1.50m wide and n.exc 1.5m depth for foundation, laying of UG cables etc or for shafts, wells, cesspits, manholes, pier holes etc not excluding 10 Sqm on plan in hard/dense soil and getting out , complete all as specified and as directed.
85Returning, filling in, including spreading, leveling, watering and well ramming in layers n.exc. 25cm in any type of soil complete all as specified and directed.
86Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point as directed.
87Supply & lay cable protection pipe of HDPE double wall corrugated (DWC) incl couplers,bends etc of size 50 mm OD and 38mm ID confirming to IS 14930 -II and ISI Marked all specified and directed.
88All as item No 69.00 above but DWC Pipe of size 75 mm OD all as specified and as directed.
89Disconnecting and taking out old defective LT UG cable with aluminium conductor of any size/type from trenches/ walls/ poles/ pipes all as directed and as specified.
90Supply,laying,jointing,connecting,testing underground XLPE insulated,PVC seathed, armoured heavy duty electric LT cable,1100volts grade with aluminium stranded conductor,10 sqmm 4 core,laid in trenches/fixed to poles/drawn through pipes with suitable size cable glands,crimping type cable lugs,sockets etc.complete and taking down the existing cable all as specified and directed.
91All as item No 71.00 above but cable of size 16 Sqmm 4 Core all as specified and as directed.
92All as item No 71.00 above but cable of size 25 Sqmm 4 Core all as specified and as directed.
93All as item No 71.00 above but cable of size 50 Sqmm 3.5 Core all as specified and as directed.
94All as item No 71.00 above but cable of size 95 Sqmm 3.5 Core all as specified and as directed.
95All as item No 71.00 above but cable of size 120 Sqmm 3.5 Core all as specified and as directed.
96Supply, laying and fixing in replacement 50 mm bore GI pipe light grade for necessary road crossing, culverts etc for cable protection all as specified and as directed.
97All as item No 72.00 above but of size 80 mm dia all as specified and as directed.
98S&F 1100 volt grade heavy duty twin core cable 10 Sq mm of size,PVC insulated aluminum conductor and taking down old unservicable wire complete all as specified.
99All as item No 73.00 above but cable of size 06 sqmm twin core all as specified and as directed.
100M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick burried directly in ground earth pit not less than 2.25 M deep below ground level with top edge of the plate not less than 1.5 M below normal ground level connected to galvanised strip of 25x4 mm by means of nuts, bolts, checknuts, washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part I of 2009 connected to earthing test pointor disconnecting / testing link including excavation/ earth work in any strata, removal of surplus earth, GI pipe medium grade 20 mm for watering and funnel, GI Pipe light grade 40mm dia for earth lead protection, PCC 1:3:6 type C1 chamber with chamber cover in RCC 1:2:4 type B1 and taking down of existing earthing
101S&Fin replacement outdoor type FRP junction box of size 300x200x105mm, light weight suitable for pole mounting using clamps/bolts and nuts including MCB SP 6 Amps single pole incl necessary connector for loop in loop out cable connectioncomplete all as specified and as directed.
102S&Fin replacementLED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impactand corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
103Material and Labour for preparation of oldsurfaces of 9 mtr high RCC Poles and applying one coat of cement based paint on RCC poles including painting black and yellow strips of 30 cm each on poles upto 1.0 m from the bottom and numbering with 60mm sized letter with synthetic enamel paint complete all as specified and as directed.
104Supply and jointing as in repair straight through joint, outdoor type 1100 volts grade, heat shrinkable type suitable for 3.5 core, 70 Sqmm to 120 sqmm LT, XLPE cable and testing after jointing complete all as specified and as directed.
105Supply and jointing in repair end termination, outdoor type 1100 volts grade heat shrinkable type suitable for 70 to 120 Sqmm LT XLPE cable and testing after jointing complete all as specified and as directed.
106S&F in replacementaluminium crimping type lugs of size 16 sqmm complete all as specified and as directed.
107All as per item No 80 above but of size 50 sqmm complete all as specified and as directed.
108All as per item No 80 above but of size 95 sqmm complete all as specified and as directed.
109All as per item No 80 above but of size 120/150 sqmm complete all as specified and as directed.
110M&L for repairing the existing LT Panel/ feeder Pillar Box any type or size by taking proper shutdown, disconnecting and reconnecting cables, welding/drilling for smooth funtioning of panel door, locking arrangement complete all as directed and as specified by Engineer in Charge.
111S&Fin replacement indicating lamps LED type set (R,Y,B) all as specified and directed
112S&F in replacement of MCCB 63A, 4 Pole, 16 KA,adjustable , fixed in existing panel including modification of existing frame and panel board door for proper installation of MCCB and connecting with existing cable including thimble,nut bolt and washers etc complete.
113All as per item No 83 above but of MCCB 100A, 4 Pole, 16 KA all as directed and as specified.
114All as per item No 83 above MCCB 125 Amp 25 KA 4 pole adjustable type415 Volts 50 Hz complete all as specified and as directed.
115M&L for fabrication of MS busbar Chamber outdoor type of nominal dimension not less than 500 mm x 500 mm x 300 mm duly provided with 04 Nos aluminimum bus bar alongwith space for fixing one 4 Pole MCCB weather/vermin proof with both way opening duly provided with neoprene rubber gasket on CRCA steel sheet encloser including making connection /thimbles complete all as sepcified and directed
116Supply only insulation tape 6m long for electrical insulation.
117M&L for cleaning of service tanks of the capacity as mentioned below on roof top of bldgs upto forth storey after disconnection from inlet and outlet pipe, removing of float valve of service tank and keep aside safely for reuse drain out water through drain plug, cleaning thoroughly to remove all scales and dirt by brushing internal surface, cleaning properlyinside with bleaching powder, flushing out with fresh water, re-positioning of tank at same place, re-connecting inlet and outlet pipes, closing of drain plug, re-installation of float valve duly cleaned, writing/ labelling the record of cleaning carried out with white/black bold letter such as"TANK CLEANED ON" _____(date), including removing creepers, vegitation and roots of plants, trees branches on or surrounding of service tank complete all as directed. Note:-(i) Unit rate quoted is deemed to be included for testing of water supply in tank both inlet and outlet flow during next supply hours. (ii) Contractor shall maintain a register for cleaning carried out with date and obtain users signature and remarks if any and this register to be submitted to JE E/M alongwith RAR. (iii)Contractor is liable to rectify any damages to the external finishes of the bldg occured during the cleaning process, i.e. scrubbing and touch up with external paints as existing specifications. Unit rate quoted is deemed too be included the cost of the same. (iv)All sort of petty T&P items such as ladder, safety equipment, nuts, bolts, washers etc. required to accomplish the job shall be provided by the contractor with out any extra cost to dept. for Following :- (a) PVC tank upto 500 litres
118(b) PVC tank upto 1000 litres
119(c) PVC tank upto 2000 litres
120(d) PVC tank upto 3000 litres
121(e) RCC semi UG Sump 20000 liters
122S&F in repair PVC tank cover top for water storage tanks suitable for 500/1000 ltrs capacity as per existing colour complete all as specified and as directed.
123All as per Item Sl Item No 87 above but of size 2000/5000 ltrs capacity
124S&F in replacement of Rotational moulded polyetheylene (HDPE) double layered ISI marked Water Tanks of 500 Ltr capacity Cylindrical & Vertical Type, ISI marked, hoisted and fixed in position with PVC cover including provision of 40mm / 25mm dia spouts for connecting inlet, outlet, over flow and washout pipes complete all as specified and as directed.
125All as per Item Ser Item No 88 above butbut of size 1000 ltrs capacity
126All as per Item Ser Item No 88 above butbut of size 2000 ltrs capacity
127S&F in replacement of20mm CPVC pipes SDR 13.5 & Plain CPVC SDR 13.5 grade with all types offittingssuch as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc as required at site, fittings on walls/ceiling or laying in floors complete all as specified and directed .
128All as per Item Ser Item No 89.00 above but of25mm CPVC pipes
129All as per Item Ser Item No 89.00 above but of40 mm CPVC pipes
130All as per Item Ser Item No 89.00 above but of50 mm CPVC pipes
131Material and labour for detecting leakage in GI Water Supply GI Lines of size20mm dia to 25 mm dia by necessary excavation, returning /filling as required, tightening of lose joints of union ,elbow, socket nipple as per site requirement including replacement of all fittings such as GI union ,socket, nipple etc as required complete all asdirected.
132All as per item No 90.00 above but size50/40 mm bore
133S& F in replacement steel water tubesmedium grade (ISI marked) galvanised with all fittings and fixed to walls or laid on floor or in ceilings of size 20 mm bore pipe alongwith all fittings as per site reqirement including taking out of old pipelines complete all as specified and as directed by Engr-in-Charge. Make : Tata/Jindal/Bansal
134All as per item No 91.00 above but of size 25 mm dia.
135All as per item No 91.00 above but of size 40 mm dia.
136S&F in replacement for union socket of 20mm bore CPVC pipes of pressure rating 10Kgf/sqcm fixed Schedule 80 gradedcomplete all as specified and directed
137All as per item No 92.00 above but of size 25mm bore
138All as per item No 92.00 above but of size 40mm bore
139S&Fin replacement forcoupler of 20mm bore CPVC pipes of pressure rating 10Kgf/sqcm fixed ofSchedule 80 gradedcomplete all as specified and directed
140All as per item No 93.00 but of size 25mm bore
141All as per item No 93.00 but of size 40mm bore
142S&Fin replacement for Elbow of20mm bore CPVC pipes of pressure rating 10Kgf/sqcm fixedofSchedule 80 gradedcomplete all as specified and directed
143All as per item No 94.00 but of size 25mm bore
144All as per item No 94.00but of size 40mm bore
145S&Fin replacement for TEE of20mm bore CPVCpipes of pressure rating 10Kgf/sqcm fixedofSchedule 80 gradedcomplete all as specified and directed
146All as per item No 95.00 but of size 25mm bore
147All as per item No 95.00 but of size 40mm bore
148S&Fin replacement forReducer of20x15mm bore CPVCpipes of pressure rating 10Kgf/sqcm fixedofSchedule 80 gradedcomplete all as specified and directed
149All as per item No 96.00 above but of size 25x20mm bore
150All as per item No 96.00 above but of size 40x25mm bore
151S&F in replacement for 20mm dia ball valves, Union Type, high pressure, CPVCpolythene gateand flynut complete all as specified and as directed.
152All as per item No 97.00 but of size 25mm bore
153All as per item No 97.00 but of size 40mm bore
154All as per item No 97.00 but of size 50mm bore
155S&F in replacement of CPVC FTA of 20mm bore pipes of complete all as specified and directed
156All as per item No 98.00 but of size 25mm bore
157All as per item No 98.00 but of size 40mm bore
158S&F in replacement of CPVC MTA of 20mm bore pipes of complete all as specified and directed
159All as per item No 99.00 but of size 25mm bore
160All as per item No 99.00 but of size 40mm bore
161M&Lfor CPVC Adhisive solution Gel type of Each 118ml Tin for jointing of CPVC Materials.
162Dismantling of motor pump sets, removing electrical connections for servicing /rewinding /replacement of bearings etc, refixing the motor pumpset in original position including making proper allignment and necessary electrical connections, testing of the 05 HP capacity pump motor sets complete all as specified and as directed
163M&L for taking out old burnt winding of stator and rotor, cleaning the slots and re-winding of motor with suitable gauge super enamelled copper winding wire, varnishing, insulation, ovening, greasing, replacement of bearing etc of 5 HP capacity motor including complete all as specified and as directed. Note : (a) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (b)The pumpset shall be spared for one week for repair from the date of complaint given by the department regarding breakdown. TheContractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (c)Please note that this penalty is exclusively other then the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (d)The decision of the Accepting Officer in this regard shall be final and binding. If the same motor copper winding wiring burnt second time in the above CA Period, Thecontractor is responsible to paid and rewind the same at their own cost.
164S&F in replacement of Gun Metal Foot valveof 50 mm bore including necessary bolts and nuts and fittings as required at site complete all as specified and as directed
165S&F in replacement monoblock pump set 1 Ph, Speed-2700 rpm of capacity 0.75 kw with suitable starter complete all as specified and as directed. Make:Kirloskar, Cormpton or equivalent
166S & Fas in replacement Sluice Valve, Cast Iron body, Stainless Steel Spindle, Gun Metal Rings including Wheelfor operation, Flanged and Drilled, 80 mm bore of pipe, confirming to IS - 14846, Class PN -1.6, Long Body type including all Joints with Rubber Gasket and Jointing Materials, Bolts, Nuts, Washer complete all as specified and as directed.
167All as per Item No. 105.00 above, but 100mm bore
168M&L for construction of valve chamber of size 600mmx600mm x600mm internal size suitable for sluice valve with PCC 1:3:6 type (C2) (using 40mm graded aggregate) for foundation, one hollow block masonry wall in cement mortar (1:4), 40mm thickPCC (1:2:4) type B1 (using 20mm graded aggregate) coping, rendering in CM 1:4, 15mm thick including provision of mild steel sheet cover of 3mm thick on 40x40x6 mm angle iron frame work emmbedded in concrete with suitable hinges and locking arrangements including two coats of black synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and including necessary excavation earth work on any type of soil etc. including removal of surplus soil and rubbish not exceeding 50m distance, including demolition of old valve chambers complete all as specified and as directed.
169All as perItem No 106 above but of size 900 x 900x 900mm
170S&F in replacement of DOL starter 415 volt including testing for motor capacity of 5 HP complete all as specified and as directed. Make:L&T or equivalent in BCH
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail