Madhyanchal Vidut Vitran Nigam Limited has published Tender For Increasing Capacity Of Transformer And Additional T/F Installation Under Business Plan 2024-25 Under Jurisdiction.. Submission Date for this Tender is 15-05-2024. Transformer Supply Tenders in hardoi Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 03-May-2024 | DATE EXTETION | Date | 06-05-2024 |
2 | 06-May-2024 | DATE EXTETION11 | Date | 08-05-2024 |
3 | 08-May-2024 | DATE EXTETION111 | Date | 15-05-2024 |
FileName | File Description | File Size |
046a9397-f567-477f-998b-be3e382d30b4.html | Tender Notice | 0 KB |
BOQ_1594889.xls | Tender Document | 0 KB |
TD167.pdf | Tender Document | 0 KB |
Tendernotice_1.pdf | Tender Document | 0 KB |
Sl. No. | Item Description |
1 | Safe carriage, loading-unloading with proper stacking of following material from store centre to pit site/JE dump store. |
2 | Top Channel with clamp (125×65×2240)mm |
3 | Dropper Channel with clamp (100×50×2028)mm |
4 | T-off Channel with Clamp |
5 | Sub Station base angle (75×75×6×2028)mm |
6 | LT Clamp with nut bolt |
7 | LT Shackle Insulator |
8 | Nut Bolt for shackel Insulator |
9 | 25 KVA T/F |
10 | 63 KVA T/F |
11 | 100 KVA T/F |
12 | 250 KVA T/F |
13 | PCC Pole 8.5 Mtr. Long |
14 | STP Pole 11 Mtr. Long |
15 | LT XLPE Cable Alluminium 1×240mm2 |
16 | LT XLPE Cable Alluminium 3.5×150mm2 |
17 | LT XLPE Cable Alluminium 1×400mm2 |
18 | ABC Cable (3×50+1×70+1×16)mm2 |
19 | ABC Cable (3×95+1×70+1×16)mm2 |
20 | ABC Cable (3×120+1×95+1×16)mm2 |
21 | G.I. Wire 6 SWG |
22 | 11 KV Fuese Set |
23 | Stay Set Complete |
24 | Earthing Complete |
25 | ACSR Weasel Conductor |
26 | 11 KV Disc. Insulator with fitting |
27 | 11 KV Pin Insulator with G.I. Pin |
28 | Work |
29 | Errection of PCC Pole 8.5 meter long single pole with grouting & with all accessories. |
30 | Errection of PCC Pole 8.5 meter long double pole with grouting & with all accessories. |
31 | Errection of STP Pole 11 meter long single pole with grouting & with all accessories. |
32 | ABC Cable (3×50+1×70+1×16)sq mm stringing sagging binding and jumpering of ABC with all accessories |
33 | ABC Cable (3×95+1×70+1×16)mm2 stringing sagging binding and jumpering of ABC with all accessories |
34 | ABC Cable (3×120+1×95+1×16)mm2 stringing sagging binding and jumpering of ABC with all accessories |
35 | Stringing & Sagging of LT XLPE Cable Aluminum 1×400 sqmm as per respo norm |
36 | Stringing & Sagging of LT XLPE Cable Aluminum 1×240sqmm as per respo norm |
37 | Stringing & Sagging of LT XLPE Cable Aluminum 3.5×150sqmm as per respo norm |
38 | Ordinary earthing by 11 KV MS earth Rod 2500 mm long as per RESPO schedule. All material except earthing rod shall be supplied by the contractor. |
39 | Grouting and Nozzling of 11 KV stay set complete including fixing of necessary clamps. Accessories required including its grouting by civil material (sand, brick blast & cement). All material except stay wire shall be supplied by the contractor. |
40 | Stringing & Sagging of three phase 11 kv ACSR weasel Conductor as per respo norm |
41 | Fabrication, Installation and commissioning of 25/16/10 KVA T/F on double/single pole with all accessories. All material except 25/16/10 KVA T/F shall be supplied by the contractor. |
42 | Fabrication, Installation & commissioning of 63 KVA T/F on Double pole with all accessories. All material except 63 KVA T/F shall be supplied by the contractor. |
43 | Placement of 11/0.4 KV T/Fs from dump place to newly constructed T/Fs plinth & installation, commissioning of 100 KVA T/Fs of T/FPlinth and including jumpering with the system ( Alltherequiredmartial for abovejob shall be provided by contractor except T/Fs) |
44 | Placement of 11/0.4 KV T/Fs from dump place to newly constructed T/Fs plinth & installation, commissioning of 250 KVA T/Fs of T/FPlinth and including jumpering with the system ( Alltherequiredmartial for abovejob shall be provided by contractor except T/Fs) |
45 | Looping & chopping of tree branches for clearance of HT/LT line after clearance of line throughout pieces of tree branches of site |
46 | Installation Fixing of 11kv Fuse Set (all Material arranged by the contractor except fuse set ) |
47 | Earthing by way of Boring and lowering the "B" class GI pipe (Gindal ) of 50mm dia from ground upto water level not less than 20mtr as per standard practice |
48 | Construction of T/F plinth of size 2x2x1.5 m on a padding 0.25M deep in ground 1:5:10 cement sand and brick ballast on the top of padding brick work Ist class brick of 0.95 mtr height & 0.35 mtr wall will be constructed. Rest wall should be 0.23 mtr thick. Brick work in ratio 1:4 cement & cores Sand in the hollow portion the sand should be filled from the ground level up to 15 centimetres below from the top of wall, Cement, sand & brick Ballasts should be filled up to 15 centimetre. Two no. of channel 100x50 in length 1500mm will be grouded.0.35 CM.RCC will be done with cores sand, cement and stone ballast in the ratio of 1:2:4.The T/Fs plinth should be plastered on all sides 12mm thick in ratio 1:6 by cement and cores sand.(All the material to be arranged by the contractor). |
49 | Construction of retaining wall, fabracation & eretion of wire mesh fencing of size 3+3 & 2.0 M height around Transformer and distribution pillar box with retaining wall & 1 no. gate with locking arragement made of MS angle iron of size 50×50×6 mm jointed with nuts and bolts. The panel must be supported with MS Flat of size 50×6mm wire mesh of size 10 SWG rectangle type as per norms of RESPO. (All the material will be arranged by by the contractor at his OWN cost). |
50 | Dismantling of old & used (Existing) material and loading, Carriage & unloading from site to JE Dump store/store centre, Hardoi. |
51 | 10&16 KVA T/F |
52 | 25 KVA T/F |
53 | 63 KVA T/F |
54 | 100 KVA T/F |