Tender For Comprehensive Maintenance To Jco Or Md Accommodation At Umed Vihar And Imli Akum Vihar Under Age Br Ii At Rms, Rangapahar-Nagaland

Military Engineer Services-MES has published Tender For Comprehensive Maintenance To Jco Or Md Accommodation At Umed Vihar And Imli Akum Vihar Under Age Br Ii At Rms. Submission Date for this Tender is 13-05-2024. Building Work Tenders in Rangapahar Nagaland. Bidders can get complete Tender details and download the document.




Tender Notice

43248346
Corrigendum : Tender For Comprehensive Maintenance To Jco Or Md Accommodation At Umed Vihar And Imli Akum Vihar Under Age Br Ii At Rms
Open Tender
Indian
Nagaland
Rangapahar
13-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Comprehensive Maintenance To Jco Or Md Accommodation At Umed Vihar And Imli Akum Vihar Under Age Br Ii At Rms

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 29-Apr-2024 AMENDMENT IN TENDER DOCUMENT FOR COMPREHENSIVE MAINT TO JCO OR MD ACCN AT UMED VIHAR AND IMLI AKUM VIHAR UNDER AGE BR II AT RMS Other 13-05-2024
2 03-May-2024 AMENDMENT IN BOQ FOR COMPREHENSIVE MAINT TO JCO OR MD ACCN AT UMED VIHAR AND IMLI AKUM VIHAR UNDER AGE BR II AT RMS BOQ 13-05-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

Attachment

FileName File Description File Size
4691b718-b3c2-40fd-a8e5-927a9ca53314.html Tender Notice 0 KB
BOQ_729066.xls Tender Document 0 KB
Tender.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: COMPREHENSIVE MAINT TO JCO/OR MD ACCN AT UMED VIHAR AND IMLI AKUM VIHAR UNDER AGE BR -II AT RMS
Sl. No. Item Description
1Demolition of cement concrete in ground floors and pavings n.exc 15 cm thick above or below ground level etc complete all as specified and as directed.
2Dismantling wall and ceiling board fibre, pulp insulation etc or insulation boards any thickness including cover fillets etc complete all as specified and as directed.
3Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and as directed.
4Demolition of laid bedded and pointed in any mortar Stone slabs and tiles of any description or thickness in floors, aprons etc complete all as specified and as directed.
5Taking down chowkhat or frame with shutter without taking off shutters from the frame, size of shutter not exceeding 1.5 Sqm each complete all as specified and directed.
6Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each etc complete all as specified and as directed.
7Taking down shutters of any description not exceeding 1 Sqm eachetc complete all as specified and as directed.
8Taking down shutters of any description exceeding 1 Sqm each but not exc 2.00 Sqm etc complete all as specified and as directed.
9S & F for4 mm thick of size 600x600mmHSPC (high pressure Steam Cured) pre-Painted self embossed, textured designer boardE-Board Classic to be fixed Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. fixed in ceiling flat or Sloping complete etc complete all as specified and as directed.
10M & L for coloured non skid ceramic tiles 7 to 8 mm thick (square/rectangular),area of each tilesexceeding 0.06 sqm but not exceeding 0.11 sqm,as in floors etc set and jointed in neat cement slurry and pointed in whitecement mixed with pigment to match shade of tiles,laid over and including 15 mm thick screed bed in CM (1:6)complete all as specified and directed.
11M & L for coloured non skid ceramic tiles 7 to 8 mm thick (square/rectangular),area of each tiles exceeding0.18 sqm but not exceeding 0.38 sqm,as in floors etc set and jointed in neat cement slurry and pointed in whitecement mixed with pigment to match shade of tiles,laid over and including 15 mm thick screed bed in CM (1:6)complete all as specified and directed.
12All as per Item No. 11.00 (here-in-before) but onskirtinglaid over and including 10 mm thick bedding layer in CM 1:4 .
13M&L for glazed ceramic coloured tiles of size 350x250x 7mm/ 450mmX350mmx 7mm thick as in dado/skirting, set and jointed in neat cement slurry and pointed whitecement mixed with pigment to match shade of tiles laidover and including 10mm thick CM (1:4) backing coat etc complete all as specified and directed.
14M&L for 40 mm thk PCC (1:2:4) type B-1 using 20mm graded stoneagg as in leveling course etccomplete all as specified and directed.
15M&L for 75 mm thick PCC (1:3:6) type C2 , (using 40 mm graded stone aggregate) in plinth protection/aprons/path laid to slope of 1:12, finished fair and even without using extra cement with and including all necessary formwork to divide tha area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 10 mm wide joints throughout thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) etccomplete all as specified and directed.
16M & L for PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in coping including necessary form work etccomplete all as specified and directed.
17Demolitionof brick work including allquoins arches pillars etc built in cement mortar etccomplete all as specified and directed.
18M&L for brick work in cement mortar (1:6) using sub class "B" bricks (using old size burnt bricks)straight or curved on plan exc 6.0 m mean raidus etccomplete all as specified and directed.
19M&L for brick work with sub class "B" bricks (using old size burnt bricks) straight or curved on plan in any radius in half brick thick walls built in cement mortar 1:4, complete all as specified and directed
20Taking down cement plaster on walls built in cement mortaretc including racking out joints, hacking for key, scrubbing down with water etccomplete all as specified and directed.
21M&L for 15mm thick cement plastering in cement mortar 1:6 brick or concrete surfaces of wall finished fair and even complete all as specified and directed.
22M&L for 15mm thick cement plastering in cement mortar 1:4 brick or concrete surfaces of wall finished fair and even with out using extra cement complete all as specified and directed.
23M&L for 5mm thick cement plastering in cement mortar 1:3ceiling surfacesfinished fair and even,etc complete all as specified and directed.
24M&L for factory madePressed steel frames(1.25 mm thick MS sheet)of size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc.,including one shop coat of primer etc complete all as specified and directed.
25S&F factory made 30mm thick, flush shutters, solid core construction, with particle board core and plywood face panels complete all as specified and directed.
26S&FFactory made35 mm thick 2nd class plain framed panelled shutters (two panels) with lock rail and panel of 9mm thick B.W.P commercial ply, size of rail and stile as per IS:1003(part-I), kiln seasoned and chemically pressure treated etc complete all as specified and directed.
27S&FFactory made30 mm thick 2nd class hard wood glazed and skeleton shutters, for door open rebated and prepared to received glass gauze etc(without sash bars)edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I Section-8 clause 8.24(a) etc complete all as specified and directed.
28S&FFactory made30 mm thick 2nd class hard wood glazed and skeleton window and ventilator shutter, open rebated and prepared to received glass gauze etc(without sash bars)edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I Section-8 clause 8.24(b),provided with stiles and rails etc complete all as specified and directed.
29Material & labour 2nd class hardwood plain, solid straight chowkhats and frames, wrought, framed rebated on the solid,rounded or chamfered, put together with glue pinned at joints etc complete all as specified and directed.
30S&F for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, suppling & fixing in opening etc complete all as specified and directed.
31S&F for Factory made solid panel PVC door shutter 30mm thick (stile) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded palin colour PVC `C" channel heaving a PVC sheert strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bbottom rail; panelling of plain colour PVC sheet to be fitted in the M.S. frame wedded/ sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, suppling & fixing in the frame at site etc complete all as specified and directed.
32S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
33All as item no 32.00 (here-in-before) but without glazing bar.
34S&F for Chimney bars (straight or camber) bearing bars; tongues or water bars for window frames,window guard bars, plain, let in and fixed independently in wooden frames L or T section supports for shelves etc. and similar articles conforming to Fe-290 Gde E-165 complete all as specified and directed.
35S&F Sheet glass 3mm thick, ordinary quality and glazing with oil putty in squares not exceeding 0.5sqm in each pane etc complete all as specified and directed.
36Hacking out old broken glass of any thickness size or description from wooden frames or metal frames fixed with wooden beads/ putty and providing and fixing new ones etc complete all as specified and directed.
37S&F in repairs, galvanised mild steel wire cloth, 0.56 nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples etc complete all as specified and directed.
38S&F in repairs Sheet glass 3mm thick, ordinary quality and glazing with oil putty in squares not exceeding 0.5sqm in each pane upto 10 m high bldg etc complete all as specified and directed.
39S&F for mild steel conforming to Fe 410-0 or Fe 310-0 in bands, straps, supports or stays for rain water, including bolts, if required, hook and pintle hinges; hand made sliding bolts; clamps; hold fasts; hooks for hanging fans and similar small articles etc complete all as specified and directed.
40S&F Butt hinges, medium weight, cold rolled mild steel,75mm size etc complete all as specified and directed.
41S&F Butt hinges, medium weight, cold rolled mild steel, 100 mm size etc complete all as specified and directed.
42S&F Aluminium, anodised, barrel tower bolt 200mm longof extruded section and fixed etc complete all as specified and directed.
43S&F Aluminium, anodised, barrel tower bolt 150mm longof extruded section and fixed etc complete all as specified and directed.
44S&F for 300mm aluminium alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts fixed etc complete all as specified and directed.
45S&F Extruded aluminum alloy handle, fabricated type, anodised 100 mm size etc complete all as specified and directed.
46S&F Extruded aluminum alloy handles, fabricated type, anodised 150 mm size etc complete all as specified and directed.
47M & L for block boards, 18/19 mm thick, , grade 1 quality, exterior grade, commercial type, fixed with screws to timber frame-work commercial type fixed with screws to timber frame work , for cup board including lipping / beading as required complete all as specified and directed.
48S & F 18/19 mm thick Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work,for cup board including lipping / beading as required complete all as specified and directed.
49M&L for preparation of new plasteredsurfaces of walls and applying twocoats of oil bond distemper over a coat of primeretc complete all as specified and directed.
50S&F in repair floor door stopper overall length of cover plate 150mm of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor etc complete all as specified and directed.
51M&L for preparation of oldsurfaces of steel and iron work of any description over 10 cm width or girth not otherwise described andapplying one coat of synthetic enamel paint in any tint complete all as specified & directed.
52M&L for preparation of old painted wood and wood based surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint in any tint etc complete all as specified and directed.
53M&L for applying two coats of synthetic enamel paints over a coat of red oxide primer including prepration of new steel surfaces of any description over 10 cm in width or girth not otherwise described etc complete all as specified and directed.
54M&Lfor preparation of untreated new wooden surface of any description over 10cm width or girth and applying two coats of synthetic enamel paintover a coat of pink primer complete all as specified and as directed.
55M&L for Preparation of old decorated surfaces and appplying one coat of white wash on walls, cornices etc. complete all as specified and directed.
56All as per item No.55.00 (here-in-before) but on ceiling.
57Complete removal of exisitng treatment on walls etc. complete all as specified and directed.
58M&Lfor 2 mmthick Birla white putty/JK white wall care putty on walls etc. complete all as specified and directed.
59M&L for Preparation of old decorated surfaces by washing, scrubbing down, and applying two coats of oilbound distemper on walls etc. complete all as specified and directed.
60M&L for Preparation of old decorated surfaces by washing, scrubbing down, and applying one coat of oilbound distemper on walls etc. complete all as specified and directed.
61M&L for complete removal of existing treatment of wall and applying two coats of oil bound distemper over a coat of primer on old surfaces of walls complete all as specified and directed.
62M&L forPreparation of new plasteredsurfaces of walls and applying three coats of white wash etc completeall as specified and directed.
63M&L for Preparation of new surfaces and appplying twocoats of white wash on ceiling, cornices etc. complete all as specified and directed.
64M & L for writing letter for figures (block, Roman, italic or indian) n exc 30 Nos CM high with thick synthetic paint with out bursh marks, if necessary repainted until the desired result is obtained etc completeall as specified and directed.
65S&F in repair 15mm bore long bodybib cock chromium plated fancy type, screwed down, screwed for iron pipe or for brass ferrule etc completeall as specified and directed.
66S&F in repair 15mm diapillar tap cast copper alloy chromium plated fancy type(ISI Marked) etc completeall as specified and directed.
67S&F in repairs Pillar tap with aerator, cast copper alloy with capstain heads, chromium plated, fancy type, screwed down with high pressure, with or without lettered "Hot" or "Cold" with long screw shanks and fly nuts, screwed for iron pipe and fixed for 15 mm bore dia of pipe etc completeall as specified and directed.
68S&F GI pipe medium grade 15 mm dia with all fitting laid in floor or fixed in walls including taking down old GI tubes etc completeall as specified and directed.
69S&F GI pipe medium grade 20 mm dia with all fitting laid in floor or fixed in walls including taking down old GI tubes etc completeall as specified and directed.
70S&F brass chromium plated angle cock 15mm bore with crutch or butterfly handle screwed to iron pipe, fixed in repair etc completeall as specified and directed.
71S&F in repair CP towel rail 600mm long with brackets, chromium plated 20mm dia in repair etc completeall as specified and directed.
72S&F brass CP shower rose 100mm size with swivel joint fixed in repairs etc completeall as specified and directed.
73S&F in repair PVC low level flushing cistern of 10 ltrs capacity incl flush pipe complete fixed in repairs etc completeall as specified and directed.
74M&L for vitreous china squatting pan, Orissa, pattern size 580 x 440 mm white with integral foot rests(excluding flushing cistern and flush pipe)including connection to trap and to flushing pipe, anti-syphonage pipe etc complete including making good to floor complete all as per specified and directed.
75S&F in repairs Vitreous china wash down water closet pan, (pedestal pattern), white, with and including plastic water closet seat, white, closed pattern with flat bottom, andcover and mild steel chromium plated or aluminised hinging device etc completeall as specified and directed.
76S&F mirror of size 450x600x5mm thick with aluminium frame and mounted on 6mm ply confirming to IS, with two Nos of hanging hooks fixed in repairs etc completeall as specified and directed.
77S&F in repair PVC connection pipe 15mm bore 450mm long etc completeall as specified and directed.
78S&F waste pipe 750 long for WHB or sink in repairs etc completeall as specified and directed.
79S&F in repair vitreous china white wash hand basin flat back size 550x400mm etc completeall as specified and directed.
80S & F in repairs 75mm dia, PVC (SWR) floor trap, plain with grating including jointing with solvent cement etc completeall as specified and directed.
81S&F in repairs CP Health Faucet with 1 mtr metalic Expandable tube & hook complete all as specified and directed.
82S&F plastic water closet seat cover, black closed pattern with flat bottom and cover and MS chromium plated or aluminium hanging device ,fixed in repair,complete all as specified and directed.
83Demolition of cement concrete (unreinforced) of any description and in any position including taking out water closet Indian type/ EWC and removal of lime concrete bed, "P" or "S" trap and cleaning the sunken portion etc completeall as specified and directed.
84M&L Water proofing treatment on RCC roof etc. comprising with the following operations and as specified herein below :-(a) Taking down/scrapping out existing old tarfelt bituminous compoundincluding, sweeping, cleaning, washing down to remove dust etc and removing debris to a distance n.exc. 250m.(b) 15 mm thick plastering in cement mortar 1:4 mixed with WPC @ 3% by weight of cementfinished even & smooth and curing for minimum 7 days. (c) Preparing & cleaning of fully dried cement plastered surface (d) Applying one coat of cold bituminous primer to the plastered surface @ 0.25 litres per Sqm conforming IS-3384 - 1986 (e) A layer of APP based polymeric membrane 3mm thick (minimum), weighing 3.5 kg per Sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/sqm )shall be applied over bituminous primer as specified above.Application of polymeric membrane shall be by torch application. The over lap shall be minimum 100 mm on transverse direction and 75 mm on longitudinal direction etc completeall as specified and directed.
85M&L for (a) Top of RCC slab in sunken portion including peripheral beams shall be plastered with 15mm thick cement and sand mortar (1:3) using approved water proofing compound @ rate of 3% by wt of cement and finished even and smooth with out using extra cement and curved adequately and allowed to dry. (b) Two coat of epoxy resin/polymer modified cementaticious coating like brush bond of Fosroc or equivalent both on floor or wall/beam shall be applied as per manufacturer"s instruction. (c) Slab to be given 1:20 slope outwards with 25mm GI pipes spout with 300mm projection beyond outer surface of wall. (d) Water tightness by flooding for 72 hours the same shall be filled with lean concrete (1:4:8) type D2 using cinder upto required depth (lean concrete will be measured seperately). Surrounding to WC Pan shall howeverbe of limeconcrete as spd and directed. (e) All stages shall be passed by GE personally.
86M & Lcement concrete type D-2, (1:4:8), using 40mm graded stone aggregate as in fillings for sunken portionand mass concrete etc completeall as specified and directed.
87Demolition and breaking up drain pipes (salt glazed, stoneware, AC or reinforced concrete/PVC pipe) set in cement mortar/concrete 75 /110 mm dia fixed in position etc completeall as specified and directed.
88S&F 110mm dia PVC (SWR) pipes single/double socketed in any length with rubber ring joints, fixed to walls etc completeall as specified and directed.
89All as per item No.60.00 (here-in-before) but bore of pipe 75 mm dia fixed to walls etc completeall as specified and directed.
90S&F(SWR) 110mm bore pipe junction single (single T) equal and unequal with access door in repair etc completeall as specified and directed.
91S&F PVC (SWR) branch piece, double (double Y) equal or unequal 110mm bore in repair etc completeall as specified and directed.
92S & F 110 mm dia PVC (SWR) vent cowl in repair complete all specified and as directed.
93Re-fixing only 110mm dia PVC (SWR) pipes single/double socketed in any length with rubber ring joints, fixed to walls after cleaning the old pipe etc completeall as specified and directed.
94All as per item No.93.00 (here-in-before) bore of pipe 75 mm dia fixed to walls etc completeall as specified and directed.
95S&F PVC ( SWR) bends 110mm bore of any radius with access door in repairs etc completeall as specified and directed.
96S & F stainless steel sink, 1mm thick for kitchen with draining board with plug and PVC waste pipe including bedding in cement mortar, fixing brackets overall size 915x460mm, bowl size 410x330x 160mm, asfixed in repairs etc completeall as specified and directed.
97Supply and fixing in repair stainless steel (conforming to AISI-304 grade) plate rack of overall size 750mm x 600mm x 254 mm or equivalent made of 1mm thick stainless steel sheetfixed on CP cantilever brackets, etc completeall as specified and directed.
98S&F in repairsfor Draperly rod /Harrison rails of CP of 20mm dia with fixing brackets , stops, rollers and rings etc completeall as specified and directed.
99M & L for cement concrete type C-2,(1:3:6) (using 40mmgraded stone aggregates) as in surface channels and drains etc completeall as specified and directed.
100M & L for Extra forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement etc completeall as specified and directed.
101Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete, including fitting&fixtures such as switches with board, ceiling roses, pendents, bell/buzzer, bell push, lamp holders, regulators, sockets, light fittingsetc. removing materials from site and making good to the disturbed surfaces of walls, ceiling floors etc. including making good the disturbed surfaces and paint touch up to match with the existing surface complete all as specified and as directed.
102M&L for Point wiring complete with two runs of 1.5 sqmm single core PVC insulated FR-LSH cable1100 volts grade with multi-stranded copper conductors, drawn throughand including PVC double locked Casing & caping/PVC Conduit pipe medium grade including provision of 1.5 sqmm, FR-LSH, PVC insulated copper cable as earth continuity conductor connected to common earth dolly, including PVC rectagular box for mounting switches / sockets / regulators etc. with 3 mm thick plastic laminated sheet cover of suitable size as required at site etc completeall as specified and directed.
103(a) Onelight controlled by one, one way switch.
104(b) One Ceiling fan/ Exhaust fan point controlled by one, one wayswitch.
105(c) One 3 pin socket outlet 5 Amps on the same board with other switches.
106(d) One 3 pin socket outlet 5 Amps on the switch socket Independent
107(e) One bell pointcontrolled by one, one way switch .
108All as per item No- 102.00 here-in-before but with 2.5 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor connected to common earth dolly etc completeall as specified and directed.
109M&L for Switch Piano, flush type single pole, one way 5 Amps etc completeall as specified and directed.
110M&L for Socket outlet, 2 in 1, 5 pin 5A flush type etc completeall as specified and directed.
111M&L for Switch Socket combination, 2 in 1, 5 pin 6A flush type etc completeall as specified and directed.
112M&L for Switch Socket combination, 2 in 1, 5 pin 6A/16A flush type etc completeall as specified and directed.
113M&L for stepped type electronic fan regulator 100 Watt socket size flush type on the existing phenolic laminated sheet etc completeall as specified and directed.d
114M&L forceiling rose 3 terminal PVC/Polycarbonate isolated body with PVC round/squareblock etc completeall as specified and directed.
115M&L for replacement of Bell AC 230 volts musical type etc completeall as specified and directed.
116M&L for bell push switch 5 amps piano type flush type etc completeall as specified and directed.
117M&L for repllacement 20W LED, 4", Wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver.etc with all accessories internally pre-wired and fixing the same and connecting upwith flexible copper cable from ceiling rose to the light fitting etc complete all as specified and as directed.
118All as per item No.113.00 (here-in-before) but LED tube light fitting 10 Watt .
119M&L for Lamp holder , PVC/ Polycarbonate type with PVC round/square block for lamp holder incl taking down old unsv light fitting etc complete all as specified and as directed.
120M&L for LED lamp 9 Watt suitable for lamp holder fittings incl taking down old unsv led lamp etc complete all as specified and as directed.
121Supply and fixing for PVC switch board 10"x12" suitable for switch socket etc complete all as specified and as directed.
122Supply and fixing for PVC switch board 8"x10" suitable for switch socket etc complete all as specified and as directed.
123All as per item No.117.00 (here-in-before) but PVC switch board 8" x 6".
124All as per item No.117.00 (here-in-before) but PVC switch board 7"x4"
125All as per item No.117.00 (here-in-before) but PVC switch board 4" x 4"
126M&L for replacement of PVC cassing & caping 20/25 mm(one length of 2 metre) etc complete all as specified and as directed.
127All as per item No.121.00 (here-in-before) but in 25/32 mm.
128M&L for sub main wiring Casing capingtwo run 4.0 Sq mm and one run of 4.0 Sq mm for earth wire with multi standard copper conductors, 1100 volts grade, drawn throughand includingcasing caping complete all as specified and as directed. NOTE:- Two runs of 4.0 Sq mm +one run of 4.0 Sq mm and one run of PVC conduit pipe and its accessories of suitable size shall be measured as one unit length.
129M&L for MCB Distribution board double door type TPN 4 way, sheet steel, powder painted, with copper bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacityincluding taking down old unsv MCB DBs complete all as specified and as directed.
130M&L for MCB TPN 63 Amps, 415 volts, 50 Hz suitable for fixing in MCB DB "C" seriesincl taking down old unsv MCB complete all as specified and as directed.
131M&L for MCB Distribution board double door type SPN 8 way, sheet steel, powder painted, withneutral link & earth bar etc. and fixing MCBs of various rating capacity incl taking down old unsv MCBcomplete all as specified and as directed
132M&L for in Replacement ofMCB SPN 32 amp rating 240V, 10KA "C" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioningincl taking down old unsv MCB complete all as specified and as directed.
133M&L for MCB SPN 40 to 63 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB "C" seriescomplete all as specified and as directed.
134M&L for MCB SP 5-32 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB "C" series etc complete all as specified and as directed by Engr-in-Charge.
135Supply , fixing and testing in replacement of LED Bldg Security light fitting of capacity 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including 1.2 mtr GI bracket of 25mm bore light grade bent to shape and fixed on wall with metal fastners 2 Nos 10mm dia incl drilling of holes as reqd and connecting up with flexible copper cable of size 0.75 sqmm 3 core from ceiling rose to the light fitting incl taking down etc complete all as specified and as directed by Engr-in-Charge.
136S&F for decorative globe light 8" dia made up of high grade unbrekable polycarbonate material suitable for retrofit LED lamp B22 including base holder bracket, MS pipe 40mm dia 1.5 mtrs long complete with 9 Watt LED Bulb and all accessories etc complete all as specified and as directed by Engr-in-Charge.
137M&L for flexible copper wire 23/76 wire etc complete all as specified and as directed by Engr-in-Charge.
138Taking down and Supply and fixing PVC Exhaust fan PVC200 mm sweep single phase 50 Hz AC, air flow rate of1350 RPM including fixing on wall with suitale fastners, making holes of suitable size and making good distrubed surfaces area etc complete all as specified and as directed by Engr-in-Charge. Note : Old exhaust fan shall be deposited to MES Store (AGE E/M)
139All as per item No.134.00 (here-in-before) but 250 mm sweep single phase 50 Hz AC .
140Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers etc complete all as specified and as directed by Engr-in-Charge. Note : Old exhaust fan shall be deposited to MES Store (AGE E/M)
141Supply & Fixing 1200mm BLDC 5 star ceiling fan with regulator enable motor powerinput 27 watt with 10% tolerance , motor insulation B type , 230-240V 50Hz AC supply 350 rpm , 225 CMMair delivery service value minimum 7.4 with complete set 3 blade , canopy,down rod , Shackle remaining all accessories including nut & bolt washer as required etc complete all as specified and as directed by Engr-in-Charge. Note : Old Ceiling fan shall be deposited to MES Store (AGE E/M)
142S&F Fan capacitor of capacity 2.5 MFD (Make: Universal/Usha) etc complete all as specified and as directed by Engr-in-Charge.
143S&F Ball bearing/Bush bearingsuitable for ceiling fan,of any sweep. Makeof bearing-TATA,NBC,SKF (6201 to 6204) etc complete all as specified and as directed by Engr-in-Charge.
144S&FFan clamp MS including nut, bolt, rubber reel, split pin complete of suitable size 1200/1400 mm etc complete all as specified and as directed by Engr-in-Charge.
145Supply , Fixing and testing of vertical type wall mounted storage water heater of Capacity 25 Ltrs BEE 5 Star rated or minimum Standing Loss of 0.511 kWh , 240V, 50Hz with Maximum power consumption of 2KW , dry powder fero glass line coating technologyfor inner tank with incoloy heating elementwith minimum4 years warranty , ABS outer body , 2 units of PVC connection pipe with length of 450mm length for hot and cold water supply with complete Accessories etc complete all as specified and as directed by Engr-in-Charge.
146Supply and fixingfor Heavy duty PK Aqua 2 feet hot water connection for geyser hose pipe both cold and hot (set of two)water line with adopter and washer at both ends of the pipe etc complete all as specified and as directed by Engr-in-Charge.
147Supply and fixingfor Indicator lamp round/rectangular complete all as specified and as directed.
148Supply and fixingfor Thermostat for geyser 30 to 75 degree centigrade etc complete all as specified and as directed by Engr-in-Charge.
149Supply and fixingfor Auto cut-off electric water heater geyser temperature controlling sensor any capacity complete all as specified and as directed.
150Supply and fixingfor Push type copper heating element of 1.5 KW capacity complete all as specified and as directed..
151Supply & fixing for Element Assembly (Glass coated ) suitable 25 Ltrs (GL WH models) including taking down etc complete all as specified and as directed by Engr-in-Charge.t
152Supply and fixingfor 15 Amp plug Top suitable for 15 amp socket complete all as specified and as directed.
153S&F 2.5 Sqmm wire 3 Core for geyser connection complete all as specified and as directed.
154Supply and fixingfor metal fasteners of 12mm diax100mm long for fixing geyser etc complete all as specified and as directed by Engr-in-Charge.
155Cleaning of geysers any type and size/make etc complete all as specified and as directed by Engr-in-Charge.