Tender For Repair To Various E/M Related Items To Certain Buildings And Hangers In Aor Of Army Avn Sqn And Caats In Aop Area Under Ge Nasik Road, nasik-Maharashtra

Military Engineer Services-MES has published Tender For Repair To Various E/M Related Items To Certain Buildings And Hangers In Aor Of Army Avn Sqn And Caats In Aop Area Under Ge Nasik Road. Submission Date for this Tender is 17-05-2024. Building Work Tenders in nasik Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

43248277
Tender For Repair To Various E/M Related Items To Certain Buildings And Hangers In Aor Of Army Avn Sqn And Caats In Aop Area Under Ge Nasik Road
Open Tender
Indian
Maharashtra
nasik
17-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Repair To Various E/M Related Items To Certain Buildings And Hangers In Aor Of Army Avn Sqn And Caats In Aop Area Under Ge Nasik Road

Key Value

Document Fees
INR 500 /-
EMD
INR 98000.0 /-
Tender Value
INR 49 Lakhs /-

Attachment

FileName File Description File Size
b1f16e8b-abeb-456a-8141-28b394f0265d.html Tender Notice 0 KB
8653PS.pdf Tender Document 0 KB
8653SOC.pdf Tender Document 0 KB
BOQ_729078.xls Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work : REPAIR TO VARIOUS E/M RELATED ITEMS TO CERTAIN BLDGS AND HANGERS IN AOR OF ARMY AVN SQN AND CAATS IN AOP AREA UNDER GE NASIK ROAD.
Sl. No. Item Description
1Taking down carefully copper/aluminium point wiring complete (light,fan, plug point & power complete alongwith fittings switchesmaterials to store and making good to disturb surfaces of wall/floors etc as specified & directed.
2M&L for Point wiring with 1.5 Sqmm(22/0.30mm) PVC insulated andunsheathed multistranded copper conductor cable, 1100 volts grade, ISI marked, FRLSH type drawn through and including stove enamelled steel conduit (ISI marked) of adequate size and its accessories with sunk cast iron/pressed steel terminal boxes of size 1.2mm thick, with 3mm thick plastic laminated sheet cover of adequate size for one light or one fan point controlled by one switch incl 1.5 Sqmm (nominalarea) copper conductor cable (multistrand), FRLSH type, PVC insulated and unsheathed with colour code earth wire connected to common earth dolly at one end and metalic bodies of luminaires/ fan at other end complete all as specified and directed for One light point/ fan point controlled by one, one way swtich. Note:-Unit rate include for cutting chases for conduits and sinking for boxes andmaking good to wall, floors etc.
3All as per ser item No. 2.00 herein before but with One 5 Amp 5 pin socket outlet point on same board with other switches including earth wire as specified.
4All as per ser item No. 2.00 herein before but with 4.0 Sqmm (36/0.30mm) VC copper stranded cable FRLSH type for one 15 Amp 6 pin socket outlet point including PVC cable 4 Sqmm FRLSH type copper stranded conductor as earth wire as specified & connected to commen earth & earth terminals including boards for mounting purposes.
5All as per ser item No. 2.00 here in before but on independent board.
6All as per ser item No. 2.00 here in before but one light point controlled by 2 way switches.
7All as per ser item No. 2.00 here in before but one bell/buzzer point controlled by one push button on the same board with other switches or independent.
8M&L forPoint wiring with 1.5 Sqmm(22/0.30mm) PVC insulated andunsheathed multistranded copper conductor cable, 1100 volts grade, ISI marked, FRLS type drawn through and including PVC casin and caping (ISI marked) of adequate size and its accessories with sunk cast iron/pressed steel terminal boxes of size 1.2mm thick, with 3mm thickplastic laminated sheet cover of adequate size for one light or one fan point controlled by one switch incl 1.5 Sqmm (nominalarea) copper conductor cable (multistrand), FRLS type, PVC insulated and unsheathed with colour code earth wire connected to common earth dolly at one end and metalic bodies of luminaires/ fan at other end complete all as specified and directed for One light point and one fan point controlled by one, one way swtich. Note:-Unit rate include for cutting chases for sinking for boxes andmaking good to wall ,floors etc.
9All as per ser item No. 8.00 herein before but with One 5 Amp 5 pin socket outlet point on same board with other switches including earth wire as specified.
10All as per ser item No. 8.00 herein before but on independent board.
11All as per ser item No. 8.00 herein before but one light point controlled by 2 way switches.
12All as per ser item No. 8.00 herein before but one bell/buzzer point controlled by one push button on the same board with other switches or independent.
13All as per ser item No. 8.00 herein before but with 2.5 Sqmm (36/0.30mm) PVC copper stranded cable FRLS type for one 15 Amp 6 pin socket outlet point including PVC cable 2.5 Sqmm FRLS type copper stranded conductor as earth wire as specified & connected to commen earth & earth terminals includingFibre insulation boards, treated on one face only of adequate size for mounting purposes.
14Supply and fixing in replacement of switch piano flush button 5 Amp single pole one way 230 volts white finish all as specified & directed.
15Supply and fixing in replacement of socket outlet flush type 5 pin 5 Amp multipurpose 230 volts single pole one way suitable for 3 pin/2pin 5 Amp plug top white/ivory finish all as specified & directed.
16Supply and fixing in replacement of switch socket combination flush type 5 pin 5 Amp multipurpose 230 volts single pole one way suitable for 3 pin/2pin 5 Amp plug top white/ivory finish all as specified & directed.
17Supply and fixing in replacement of switch socket combination multipurpose flush type 2 in 1 type (3 and 3 pin) 5/15 Amps, 230V, AC.
18Supply and fix in replacement lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings with LED bulb 9 watt complete all as specified and directed
19Supply and fix in replacement ceiling rose surface PVC 50mm dia 3 terminals including PVC mounting block white/ivory finish.
20Supply and fixing in replacement of bell push, flush type, 5 Amp single pole, 230 volts white finish all as specified & directed.
21Supply and fixing in replacement of switch piano flush button 5 Amp single pole 2 way 230 volts white finish all as specified & directed.
22M&L in replacement and connecting up fan regulator electronic on existing phenolic laminated sheet dimmer type 230 volts, 450 watts suitable for ceiling fan 1200/1400mm sweep.
23Supply and fixing in replacement of LED 150 Watt highbay optica heavy duty luminaires with engineering grade diffuser for added protection, secondary optics, suitable for industrial lighting applications, with IP 65 incl connecting up with three core flexible copper conductor cable of suitable size from ceiling rose. Make :- Shakti/ Philips/ Crompton.
24Supply and fixing in replacement of LED 20 Watt inverter LED batten with rod complete with lithium ion battery with charging time 8-10 hours and backup time upto 4 hours mounted on square box of suitable size connecting up with three core flexible copper conductor cable of suitable size from ceiling rose.
25Supply and fixing in replacement of buzzer, AC, 230 volts, single phase complete all as specified and directed.
26Supply and fixing in replacement of bell, AC, 230 volts, single phase complete all as specified and directed.
27Supply and fixing in replacement of bell multi music type AC, 230 volts, single phase complete all as specified and directed.
28Supply and fixing in replacement of sheet metal enclosureswith plug socket single pole and neutral with two pin and earth plug and with one MCB of 20 Amps (SP)complete all as specified.
29Supply and fixing in replacement of sheet metal enclosureswith plug socket triple pole and earth with three pin and earth plug with socket 415 volts complete with one triple pole MCB of 63 Amps (TP)complete all as specified.
30Supply and fixing in replacement of submain wiring with three single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLSH type, cables 6 Sqmm drawn through in and including steel conduit including 6 Sqmm 1100Volts grade, FRLSH type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed.
31Supply and fixing in replacement of submain wirng with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLS type, cables 6 Sqmm drawn through in and including PVC heavy duty surface casing caping including 6 Sqmm 1100Volts grade, FRLS type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed.
32Supply and fixing in replacement of submain wiring with three single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLSH type, cables 4 Sqmm drawn through in and including steel conduit including 4 Sqmm 1100Volts grade, FRLSH type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed. Note for Srl item No 22 & 24 herein before :- (i)Three runs of cables and one run of continuous earting cable drawn in steel conduit will be measured as one length of sub main. (ii)Steel conduit and its accessories is deem to be included in this item rates. (iii) Unit rate include for cutting chases for sinking for boxes and making good to wall, floors etc.
33Supply and fixing in replacement of submain wirng with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLS type, cables 2.5 Sqmm drawn through in and including PVC heavy duty surface casing caping including 2.5 Sqmm 1100Volts grade, FRLS type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed. Note for Srl item No 31.00 & 33.00 herein before :- (i)Two runs of cables and one run of continuous earting cable drawn in casing and caping will be measured as one length of sub main. (ii)PVC casing caping and its accessories is deem to be included in this item rates. (iii) Unit rate include for cutting chases for sinking for boxes and making good to wall, floors etc.
34Supply in replacement of LED outdoor drivers, suitable for 150 watt street light fitting all as specified and directed by Enginner-in-Charge.
35Supply and fixing in replacement sheet metal enclosure (factory made), TPN Vertical Distribution Boards (MCCB Incomer) IP43 protection Double Door : Plain 4 way with 200 Amps rated busbar all as specified and directed.
36Supply and fixing in replacement sheet metal enclosure (factory made), TPN Vertical Distribution Boards (MCCB Incomer) IP43 protection Double Door : Plain 8 way with 200 Amps rated busbar all as specified and directed.
37Supply and fix in replacement distribution board sheet metal enlosure double door shutter type factory made fixed flush with wall or outside on wall surface suitable for mounting isolators & MCB"s 415 volts, 200 Amp rated bus bar with front openable cover suitable for TP & N 4 ways all as specified & directed.
38Supply and fix in replacement distribution board sheet metal enlosure factory made fixed flush with wall or outside on wall surface suitable for mounting isolators & MCB"s 240volts, 200 Amp rated bus bar with front openable cover suitable for SP & N 2 ways all as specified & directed.
39Supply and fix in replacement distribution board sheet metal enlosure double door shutter type factory made fixed flush with wall or outside on wall surface suitable for mounting isolators & MCB"s 240volts, 200 Amp rated bus bar with front openable cover suitable for SP & N 4 ways all as specified & directed.
40Supply and fix in replacement distribution board sheet metal enlosure double door shutter type factory made fixed flush with wall or outside on wall surface suitable for mounting isolators & MCB"s 240volts, 200 Amp rated bus bar with front openable cover suitable for SP & N 8 ways all as specified & directed.
41Supply and fix in replacement distribution board sheet metal enlosure double door shutter type factory made fixed flush with wall or outside on wall surface suitable for mounting isolators & MCB"s 240volts, 200 Amp rated bus bar with front openable cover suitable for SP & N 12 ways all as specified & directed.
42Supply and fixing in replacement 4 Pole MCCB 125 Amp, 50 Hz, 415 V, with adjustable thermal & adjustable magnetic setting, breaking capacity 25 KA.
43Supply and fix in replacement MCCB 63 Amp TP,415 volts 16KA.
44Supply and fix in replacement MCB FP 63 Amp, 415 Volts, 50 Hz with 10 KAM
45Supply and fix in replacement MCB TP 40 Amp, 415 Volts, 50 Hz with 10 KA.
46Supply and Fixing in replacement of MCB DP/SPN 6-32 Amps, 230 Volts, 50 Hz with 10 KA.
47Supply and Fixing in replacement of MCB SP 6-32 Amps, 230 Volts, 50 Hz with 10 KA.
48M&L for replacement of Earthing complete withgalvanised steel earth plate electrode 60cmx60cmx6.3 mm thickness burried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to and incl galvanised earth lead wire of 4.00mm dia by means of nuts & bolts, check nuts and washers of galvanised incl PCC pit of 1:2:4 type B-1, cover reinforced with XPMweightnot less than 4 Kg/Sqm and 6mm dia bar handle, earth pit angle iron frame of size 25mm x 25mm,excavation and earth work in anytype of soil, charcoal dust, salt, light grade GI watering pipe 20mm dia with funnel and wire -mesh and medium grade GI protection pipe of 15mm bore from top edge of earth plate upto main distribution board complete allto as shown in electrical plate No 3 of MES Sch 2009 (Part I) connected main switch board all as specified and testing on completion.
49Supply and fixing in replacement of 35 Watt LED street light fitting luminaire, energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08. , including coneecting up with 2/3 core flexible coppper conductor cable , compete all as specified and directed by Engr-in-Charge.
50Supply and fixing in replacement of LED luminaire 600mm x 600mm, 36 watt,WW/NW220 volts, 2500K to 3000K, AC recessed/ surface type fittings, epoxy powder coated CRCA sheet housing with electronic driver, connector block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.
51Supply and fixing in replacement of 1000W, 120V Beacon lamp holder for Rotating Beacon 1000W AB all as specified and directed.
52Supply and fixing in replacement of power unit for Rotating Beacon 1000W AB all as specified and directed.
53Supply and fixing in replacement of carbon brushfor Rotating Beacon 1000W AB all as specified and directed.
54Supply and fixing in replacement of Slip Ring for Rotating Beacon 1000W AB all as specified and directed.
55Supply and fixing and testing in replacement of rotating aerodrome beacon light clear/green lens all as specified and directed.
56Supply and fixing and testing in replacement of 48 volts DC supply, SMPS Rotating Aerodrome Beacon Light Clear/ Green Lens all as specified and directed.
57Supply and fixing and testing in replacement of 110 volts Master Card Rotating Aerodrome Beacon Light Clear /Green Lens complete all as specified and directed.
58Supply and fixing and testing in replacement of 110 volts Motor for Rotating Aerodrome Beacon Light Clear/Green Lens complete all as specified and directed.
59Supply and fixing and testing in replacement of PAR lamp 1000Watt, 220 volts, 50 Hz complete all as specified and directed.
60M&L for lifting and re-installation, testing and commissioning Rotating Aerodrome Beacon light Clear/Green Lens complete all as specified and directed by Engineer in Charge.
61M&L for replacement of Earthing complete withCopper earth plate electrode 60cmx60cmx3.15 mm thickness burried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to and incl copper strip of size 20mm x 3mm by means of nuts & bolts, check nuts and washers of brass incl PCC pit of 1:2:4 type B-1, cover reinforced with XPMweightnot less than 4 Kg/Sqm and 6mm dia bar handle, earth pit angle iron frame of size 25mm x 25mm,excavation and earth work in anytype of soil, charcoal dust, salt, light grade GI watering pipe 20mm dia with funnel and wire -mesh and medium grade GI protection pipe of 32mm bore from top edge of earth plate upto main distribution board complete allto as shown in electrical plate No 3 of MES Sch 2009 (Part I) connected main switch board all as specified and testing on completion.
62M&L for dismantling of existing earth strip of any type/size from roof top of hanger/wall of hanger and re-fixing the same after completion of B&R nature work completed all as specified & directed by Engr- in- charge.(Note): (i) Rate included for dismantling re-fixing of existing earth strip including epoxy/proceiling insulation. (II) Refixing of lightining conductor/rod on existing portion.
63Supply and fixing in replacement of LED flood light 100 watt 230 volts AC outdoor type with thermal managem,ent in multiple optics and equipped with IP66 protection with impact and corrosion resistant complete with driver and accessories all as specified and directed by Engineer in Charge.
64Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr deep and getting out in soft loose soil all as specified and directed
65Returining, filling in including spreading, levelling watering and well ramming in layer not exce 25 cm, all as specified and directed
66Removing excavated soil to a distance not exce 50 mtr and deposited where directed at a level not exceding 1.5 mtr abvoe the starting point all as specified and directed.
67S&F in replacement and calibration of Wireless-Addressable CMS PANEL (CENTRALISED MONITORING SYSTEM),Using 7"" colour display, Inbulit hooter 110DB,Battery Backup 8 hrs, (0-100 DEVICES)(automatic battery charging, history capacity-50% of devices, zone capacity-120 )with insert fuse holder, open central main panel with two floating wires with proper connectivity (red & Black wire) Antenna SMA Connectorwith 12 vbattery ,7.3 Ahand check all system in identify dective items and replacement of the same with same capacity. Note:- (i) Item requried for replacement will be measured & Paid seperatly under respective Items.
68S&F in replacement of Wireless addressable Hooter panel with inbuilt battery backup 8 hrs and inbuilt hooter 110 DB (Operating voltage -12 V DC FM modulation) check connectivity of wires red and black and check antennaof SMA connector with suitable top panel. check the connector of male and female and lead acid battery type 12V ,1.3 Ah after repair check the test button of dector or MCP.
69S&F in replacement of Wireless Addressable Manual Call Point(MCP).(voltage range-3-9 VDC, standby current- 5 µA, FM modulation, manual type, unique address)
70Supply onlyof Hooter/Sounder
71Supply only of 24v DC SMPS
72Repair and replacement of Wireless Addressable Beam Detector with check the transmitter/ receiver unit and reflactor and check the princple of light obscuration and check the percentage ofof beam lightand check laser beam pointer,transmitter, red switch (SW 1) , terminals, Red LED (HL3), Green LED (HL1), Vertical adjustment, M4x12 Screw, Horizontal adjustment, DIP Switch (SW2) and Display digital guide.
73Supply and laying in replacement DI Pipes heavy class,K9with flanged end of thickness minimum 12mm,with all fittings and fixed complete laid in trenches of size 150MM.
74Supply and laying in replacementK9 DI Pipes heavy class, with flanged end of thickness minimum 12mm,with all fittings and fixed complete laid in trenches of size 100MM.
75Supply and laying in replacement GI tubing heavy class, with flanged end of thickness minimum 12mm,with all fittings and fixed complete laid in trenches of size 40 MM.
76Supply and laying GI tubing heavy class, with flanged end of thickness minimum 12mm,with all fittings and fixed complete laid in trenches of size 50 MM.
77Supply and laying in replacement GI tubing heavy class, with flanged end of thickness minimum 12mm,with all fittings and fixed complete laid in trenches of size 25 MM.
78Dismantling existing unserviceable sluice valve upto 100 to 150 mm mm bore both end flanged including unscrewing of nut & bolts and removal of insertion sheet.
79Supply and fix 150 mm Sluice Valves with cast iron rising spindle , flanged of class As per IS 14846 Body,cover-CI IS:210,Gr.FG260 Body ring-Brozne IS:318 Ge,LTB2 Door face natural rubber Hinge pin-SS ASTM Aa2765 1.6 PN.
80All as per ser item No. 79.00 herein before but 100 mm.
81M&L for DI /CI Special fitting such as bends(any type radius and angle ) tapers any type ( straight, bend, Tee, reducers, socket , collers,caps and plugs ) upto 100mm to 150 mm dia.
82Supply & fix150 mm machanical joint/CollerISI marked for spigot end pipe.
83All as per ser item No. 82.00 herein before but100 mm.
84Supply and fix in replacement of air realease valve 80 mmDouble orifice Kinitic air valve desined.
85Supply and fix in repairs cantileaver roller with self lubricating frictionless bearings (rollers and bearings of existing size suitable for existing door) including removing of existing roller & bearing, replacement of any part/spare at site complete as directed by Engr-in-charge
86Wheels & Bearings Assembly :( defective ) Identify malfunctioning of wheel(eg. stumbling, noice, jamming etc.) dismental concirn corrugated precoated color sheets on the panel, jacking/taking down the door panel, dismental the defective wheel, cover the panel area with temperory shields.
87Supply and fix in replacement of axel, bearings, circlip assembly including taking down door panel, axel, wheel, bearing complete and refixing after replacement of axel, bearing and circlip assembly as per existing size & material. Painting of external surface of complete asembly after two coats of red oxide incl setting and alignment of complete door panel and testing of complete door upto satisfaction of Engr-in-Charge.
88Chain & Drive sprocket: Supply and fix in repair including identify disorder of pair of chain & drive sprocket (eg. slipage, noice, jamming etc.) dismental machine cover, dismantling chain by removing lock, procure new chain, lock & Drive sprocket, bore & keyway the sprocket, install new sprocket & chain on its position, align it, lubricte it, make proper tension of chain, install machine cover, check it for smooth operation as directed by Engr-in-Charge.
89Cable carriers:Supply and fix in repair including identify failed cable carriers, procure new one, replace failed cable carriers by new ones with the help of tower stand, check it for reverse & forward movement.
90M&L for Rewinding the motor (3.75 Kw/5HP) with super enamelled copper winding wire with appropriatesame gauge of exsisting coil with similar class of exsisting insulation as recommended by manufacturer with high quality normex insulating paperapplying best quality insulating varnish on stator/rotor windings drying them completely, testing the insulations as directed by engr -in - charge.
91Miniature circuit braker (MCB) 415 Volts 4P MCB 5SL63107RC, 6 to 32 Amps : identify the failed MCB, check & replace it by new one of same capacity & specifications, test by trial.
92Supply and fix in repairs 3TF34 contactor with aux. cont. block.
93Supply and fix in repairs overload relay 3UA5000-1J OLR (6.3-10A).
94Supply and fix in repairs contactor with buzzer- 220V.
95Supply and fix in repairs forward reverse push buttons 3SB5000 with NO/NC.
96Supply and fix in repairs emergency P/B 3SB5000-0UC01.
97Supply and fix in repairs indicator R/Y/B 220V.
98Supply and fix in repairs limit switch ID8108.
99Inspection & Certification by Chartered Engineer including repair in brakedown maintenance, suggested by charted engineer complete for complete one opening of hanger. (Note: contractor should submit one year Govt. authorized charted engineer certificate)
100M&L for dismantling of existing Point wiringof any type/size from Cealing ofhanger/wall of hanger and re-fixing the same after completion of B&R nature work completed all as specified & directed by Engr- in- charge (Note): (i) Rate included for dismantling re-fixing of existing point wiringincluding (ii) Refixing of point wiring on existing portion
101M&L for dismantling of existing Sub main wiringof any type/size from Cealing ofhanger/wall of hanger and re-fixing the same after completion of B&R nature work completed all as specified & directed by Engr- in- charge (Note): (i) Rate included for dismantling re-fixing of existing Sub main wiringincluding (ii) Refixing of Sub main wiring on existing portion
102NOTE : - AMOUNT OF SCHEDULE OF CREDIT RS. 1,68,891.90 WILL BE DEDUCTED FROM TOTAL AMOUNT OF BOQ.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail