Tender For Provision Of Covered Parking Shed, Cylinder Store, Interlocking Tile Along With Water Drainage At Umroi Mil Stn Under Ge Umroi, umroi-Meghalaya

Military Engineer Services-MES has published Tender For Provision Of Covered Parking Shed, Cylinder Store, Interlocking Tile Along With Water Drainage At Umroi Mil Stn Under Ge Umroi. Submission Date for this Tender is 17-05-2024. Shed Construction Tenders in umroi Meghalaya. Bidders can get complete Tender details and download the document.




Tender Notice

43245029
Tender For Provision Of Covered Parking Shed, Cylinder Store, Interlocking Tile Along With Water Drainage At Umroi Mil Stn Under Ge Umroi
Open Tender
Indian
Meghalaya
umroi
17-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Provision Of Covered Parking Shed, Cylinder Store, Interlocking Tile Along with Water Drainage At Umroi Mil Stn Under Ge Umroi

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-

Attachment

FileName File Description File Size
32a782be-9b8d-4989-ab6f-b3287607423c.html Tender Notice 0 KB
8825TenderDocs.pdf Tender Document 0 KB
BOQ_728975.xls Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: PROVN OF COVERED PARKING SHED NEAR MT AREA OF 11 MBSC, PROVN OF CYLINDER STORE, PROVN OF INTERLOCKING TILE ALONGHWITH WATER DRAINAGENEAR BLDG NO 19 AND PROVN OF TILE IN QTR NO 130/2, 03, 04, 06, 07. 08, P-119/2, 3 165/7, 174/7, 160/8, 134/1, 154/7, 8 AT UMROI MIL STN UNDER GE UMROI
Sl. No. Item Description
1Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil, complete all as specified and directed.
2Excavation in post holes (or similar holes) each not exceeding 0.50 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exceeding 50 m and making good surfaces in soft/loose soil, complete all as specified and directed.
3Excavation in trenches not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth and getting out in soft/loose soil, complete all as specified and directed.
4Material and labour for providing Plain Cement Concrete (1:4:8) type D2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete, complete all as specified and directed.
5Material and labour for Pre-cast cement concrete block masonry Type C1 (1:3:6) (using 20mm graded stone aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar (1:6), complete all as specified and directed.
6Returning, filling in trenches including spreading, leveling watering and ramming in layers not exceeding 25cm, complete all as specified and directed.
7Removing of surplus soil not exceeding 50m and deposited where directed at a level not exceeding 1.50m above the starting point, complete all as specified and directed.
8Material and labour for hardcore of broken stone of gauge not exc. 63 mm deposited, spread and leveled in layers not exc. 15cm thick, watered and rammed to a true surface, complete all as specified and directed.
9M&L for 100 mm thick PCC(1:2:4) type "B-2" (using 40mm graded crushed stone aggregate) as in flooring finished even and fair, complete all as specified and directed.
10Material and labour for plain Cement Concrete (1:3:6) type C1 using 20mm graded aggregate as in Pillars, boundary pillars, posts etc. filling and mass concrete, complete all as specified and directed.
11Supply and fix rolled mild steel work in tubular vertical post including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161 – 1979 grade St – 240, complete all as specified and directed.
12Ditto- as per item No-11 but as in truss andpurlin.
13S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of camouflage colour having tensile strength of 550 Mpa as in roof covering/clading to wall, fixed with self taping screws, complete all as specified and directed.
14S&F Pre- painted galvalume aluminum zinc coating PPGL based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, eave board, fixed with self tapping screws, complete all as specified and directed.
15Material and labour for 15 mm thick rendering in cement mortar (1:4) on fair face of brick or concrete surfaces finished even and fair, complete all as specified and directed.
16Material & Labour for Preparation of new plastered surface of wall and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified and as directed.
17Material and labour for preparation of new and previously un-treated steel surfaces of any description, not otherwise described over 10cmwidth or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and as directed.
18M&L for 75mm thick PCC(1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in path/Hardstanding, complete all as specified and as directed.
19M&L for sand spreading and levelling under inter locking paver block, complete all as specified and as directed.
20M&L for Machine pressed precast concrete interlocking rubber moulded paver block with grey cement and colour pigment any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade, complete all as specified and as directed.
21M&L for cement concrete (1:2:4) type B0 (using 12.50mm graded stone aggregate) as in cills, steps; seismic and other similar bands,plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, Copings etc including necessary formwork, complete all as specified and as directed.
22Material and labour for Reinforced cement concrete M-20 nominal mix (using 20 mm graded stone aggregate) as in drain Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilaster and buttresses, complete all as specified and directed.
23M & L for RCC Design Mix M-25 in Foundation, including raft footings, foundation beams, plinth beams,bases for column etc.,basement slabs, underreamed piles and mass concrete etc, complete all as specified and directed.
24M & L for RCC Design Mix M-25 in Beams, cantilevers,lintels, columns pillars,piers, posts, struts,chullah hoods, stair case,arches, domes, vaults,shell roofs, arch ribs,folded plates, slabs,balconies, canopies, deckslabs etc. or in similararticles etc, complete all as specified and directed.
25M&L for RCC forM 25 (Design Mix)using 20 mm graded crushed stone aggregateas in Slab,chajjas and similar work, complete all as specified and directed.
26Use and waste of formwork to sides of column, pillars, posts, stanchions for flat rough finished surface, complete all as specified and directed.
27Use and waste offormwork to sides and soffit of beams, lintels, cantilevers, shelves etc for flat rough finished surface, complete all as specified and directed.
28Use and waste of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter(Flat), rough finished surfaces, complete all as specified and as directed.
29Use and waste of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work;not exceeding 200mm thick (Horizontal or sloping), rough finished surfaces, complete all as specified and as directed.
30Use and waste of Formwork to faces of drain walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter for fair finished surfaces, complete all as specified and directed.
31M&L TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
32M&L TMT bars 8 mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
33M&L for Mild steel TMT bars 5 mm to 10 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips, complete all as specified and as directed.
34Material and labour for extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc, complete all as specified and as directed.
35M&L for 10mm thick plaster in cm (1:4) on fair faces of brick or concrete surfaces including finishing even & smooth without using extra cement, complete all as specified and directed
36Material and labour for PCC 1:2:4 type B1 (Using 20mm graded stone aggregate) as in surface channels and drains etc, complete all as specified and directed
37Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing servicable tiles to store and rubbish of the premises, complete all as specified and directed
38Taking down cement plaster, of any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water, complete all as specified and directed
39Roughening surfaces of old concrete floor by picking,sweeping clean and washing down with water to remove dust and brushing neat cement slurry with 3.00 kg of cement per sqm, complete all as specified and directed
40Material and labour forcoloured non skid ceramics tiles 7 to 8mm thick (square/ rectangular), area of each tile exc 0.11 sqm but not exc 0.18 sqm as in floors over and including 15mm thick screed bed/bedding layer in CM 1:4set and jointed in neat cement slurry and pointed in white/coloured cement to match the existing floor, complete all as a specified and directed.
41Material and labour fornon skid ceramics tiles 7 to 8mm thick (square/ rectangular), area of each tile exc 0.11 sqm but not exc 0.16 sqm as in skirting over and including 10mm thick rendering in CM 1:4set and jointed in neat cement slurry and pointed in white/coloured cement to match the existing surface, complete all as a specified and directed.
42Material and labour for coloured Glazed ceramic tiles in vertical surface of size350x 250x 7mm/ 450X 350X7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick rendering in CM 1:4, complete all as specified and directed.
43M&L for Granite (of any type) work 18mm thick (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) over and including 15mm thick screed bed/bedding layer in CM 1:4including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including taking down stone slab complete all as specified and directed.
44S&F in repair of PVC valve less syphonic action flushing cistern type 9 to 10 ltrs capacity with inlet, ball valve, float and handle including bracket, white colour, complete all as specified and directed
45Supply and fixed in repairs ofvitreous china squatting pan of Orissa pattern size 580 mmx440mm white withP or S tap front or back inlet and integral foot rest (Excluding flushing cistern and flush pipe), complete all as specified and directed
46Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth in brick walls etc, complete all as specified and directed
47Taking up or down steel tubing 15mm boreand connections including cleaning for refixing or removal to store, complete all as specified and directed
48S&F CPVC pipes 20 mm outer diameter of SDR 11 & plain CPVC SDR 11 and fittings as in walls, ceiling, floor, etc, complete all as specified and directed
49S&F in repair stop valve 15 mm dia CP fancy type, with long shank and cup (concealed type) cast copper alloy, screwed both ends for iron pipe or for unions, complete all as specified and directed
50M&L for plain cement concrete Type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete, complete all as specified and directed.
51Material & labour for 2nd class hard wood, plain, solid straight chowkats and frames worught, framed, rebated on the solid rounded of chamferred, put together with glue, pinned at joints supplied and fitted, complete all as specified and directed.
52Supply and fixing 35 mm thick Flush shutter, solid core construction, with block board core and plywood face panels,commercial type on both sides, complete all as specified and directed.
53Material & labour for preparation of new wooden surfaces of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
54Supply and fix aluminium anodised (powder coated) Ventilator frame with Shutter(bottom Half Portion Fixedand top half portion with louver)including all necessary joining cleats, hold fast, rubber gasket, snap beading and locking arrangements fixed with screws to wall etc. complete andglazing with and including 4 mm thick frosted glass to aluminium frame work and louver using rubber gasket and fixed with stainless steel wire cloth of 0.36 mm dia & average width of aperture 1.40mm outside vent with staple and suitable wall angle of size 25.4x25.40x1.1mm thick and fillets with screws and washers etc including Deco Grill of Model / Design No. DG 104 and 6.3mm thick etc (A) Section for frame63.5 X 38.1X 1.40mm thick, complete all as specified and as directed.
55Material & labour flat iron mild steel for hold fast size conforming to Fe-410-0 or Fe-310-0, complete all as specified and directed.
56S&F aluminium alloy handles size 150mm fabricated type anodised, complete all as specified and directed.
57S&F aluminium anodised barrel tower bolt 200mm size of extruded section and fixed, complete all as specified and directed.
58S & F 100 mm butt hinges medium weight cold rolled mild steel and fixed, complete all as specified and directed.
59Material and labour for 15 mm thick rendering in cement mortar (1:6) onfair faces of brick surfacesfinished even and smooth without using extra cement, complete all as specified and directed.
60Material and labour for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, chajja, fins, facia etc upto 3 storey height mixed with water proofing compound (ISI marked) @ 3% by weight of cement or as per manufacturer’s instructions, finished even & smooth without using extra cement, complete all as specified and directed. Note :- (a) Supply only water proofing compound shall be measured and paid separately under relevant items. (b) Rendering will be done in two layers. 1st layer will be 10 mm thick and 2nd layer will be 5 mm thick mixed with water proofing compound. .
61Supply only Liquid water proofing compound.
62Material and labour for 5 mm thick rendering in cement mortar (1:3) on concrete surface as in ceiling/chajja finished even and smooth without using extra cement, complete all as specified and directed.
63Material and labour for applying three coats of white wash on ceiling including preparation of new or previously untreated surfaces, complete all as specified and directed.
64Material and labour for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr, the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface, complete all as specified and directed.
65M&L for prepration ofnew plastered surfaces and applying two coats of weather proof exterior emulsion paint (Apex Ultima or equivalent) (any colour/tint)with approved colour and pattern over a coat of 1 mm thick wall care putty and a coat of approved alkali primer as on walls of bldgs of any height including necessary scaffolding and safety measures and procedure, complete all as specified and directed.
66M&L for 75 mm thick cement concrete 1:3:6 type C2 using 40 mm graded stone aggregate as in plinth protection finished even and smooth with using extra cement, complete all as specified and directed.
67Material and labour for point wiring for One light/fan point controlled by one, one way switch, with 1.5 Sqmm single core, PVC FRLSH insulated unsheathed, multistranded copper conductor drawn through and includingstove enamaled steel conduite including necessary flameproof accessories like bends, tees and elbow etc fixed on wall/ceiling with 1.5 Sqmm PVC FRLSH insulated unsheathed multi stranded copper conductor cable as earth conitinuity (green in colour) connected to common earth dolly including sunken type pressed steel terminal boxes of suitable sizes, complete all as specified and directed as below :- Note:-Rate forCutting, chieseling and making good the existingsurface for complete concealed wiring is deemed to be included in quoted rate
68All as per item No 67 here-in-before but using 2.5 sqmm PVC FRLSH insulated copper conductor wire for connecting 15A socket on independent board.
69Supply and fixing of switch piano flush type 240 Volts 5 Amps, SP, one way, complete all as specified & directed
70Supply and fixing switch socket out let combination multipurpose 3 pin, 5/16 Amps and (with 3 pin 5 Amps outlet also) flush type (non shuttered), complete all as specified & directed
71Supply and fixing ceiling rose surface PVC/Polycarbonate, 65x50 mm two to three terminals, complete all as specified & directed
72Supply and fix of MCB SPN DB 4 waydouble door,IP 43 protection,Glazed door, isolated neutral bar,insulated bus bar assembly,mechanical strength of IK09, complete all as specified and directed
73Supply and fix MCB SPN 40Amp, C series, complete all as specified & directed
74Supply and fix MCB SP 6-32 Amp, C series, complete all as specified & directed
75Supply and fix LED batten with Tube rod of capacity 18/20Watt , complete all as specified & directed
76Material and labour for earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick, burried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to earth lead wire 4 mm dia by means of nuts, bolts and washers of galvanised iron and earth lead protected by galvanised iron pipe 15 mm bore (light grade) and connected to earth test point and including cement concrete pit in PCC (1:3:6) type C-1(using 20 mm graded aggregate) and pre-cast RCC cover slab of size 540 x 540 x 50 mm thick, reinforced with 8 mm dia TMT bars both ways and one handle for lifting made with 10 mm dia mild steel bar,funnel, wire mesh 20 mm bore galvanised (medium grade) for watering, charcoal and salt in alternate layers including necessary execuation and earth works in any types of soil complete all as shown on Electrical plate No 3 of MES SSR-I including, complete all as specified & directed.
77Supply and spread sand in trenches as sand cushioning to underground cable for protection with fine river sand and provide required cover after punning down complete all as specified and directed. (Note: Thickness of sand cushion after punning down will be measured and paid.)
78M&L for common burnt clay building bricks (locally available best quality), sub-class ‘B’ designation 75 of size 230x115x75 mm to cover LT underground cables , laid dry and flat abutting each other with gaps not exceeding 10mm, complete all as specified and directed.
79Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6.0 sq mm 2 core, complete all as specified and directed.
80Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 2 core, complete all as specified and directed.
81Supply and fixing of Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V, complete all as specified and directed.
82Supply and fixing LED light fitting 1x8 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size, complete all as specified and directed
83Supply and fixing of LED street light fittings in aluminium PDC housing, toughened glass cover,individual LEDs with secondary optics,covered with IP66 protection with inbuilt surge protection of minimum 5 kV and repair/replacement warranty of minimum 3 years of capacity 35W, complete all as specified and directed.
84S&F 32 mm bore GI tubing light grade bracket over all 1.2 mtr length with cutting as required and bend to shape with flat iron clamp of size 32 mm 2 Nos, suitable size of nut bolts and washers completefor fixing street light fittings on electric poles, complete all as specified and directed.
85Supply and fix MCB Distribution board SPN 4 Way double dooor for mountingSPN/ SP MCBs as Incoming / outgoing, factory made, confirming to IS, fabricated out of CRCA sheet , fitted with DIN channel, neutral link and suitable rated bus bar, DBs shall be semi glossyfinished with epoxy polyester based powder paint sprayed and backed at high temperature, between powder paint process the sheet steel having to go through the anti rust conditioning in not less than seven tank process to ensure smoothfinish and protection against corrosion atmosphere. The DBs shall be double door type with hinged door with locking arrangement. The DBs shall be of IP 43 - IK 09 with metal door, complete all as specified and directed.
86Supply & fix MCB SPN 32 Amps"C" Series 10 KA 240 volts, complete all as specified and directed.
87Schedule of Credit