Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work excavation by mechanical means(hydraulic excavator)/manual meansfor foundation, trenches etc., in all types of soils below ground level including shoring, strutting, bailing / pumping of water, leveling, ramming the bottom of excavation, refilling with selected excavated materials in the sides of the foundation in layers, consolidating and disposing off the surplus earth at places as directed within a lead of 50 m all as per drawings and specifications. |
| 2 | upto 1.5m ht |
| 3 | Extra for every additional lift of 1.5m or part thereof |
| 4 | Earth work excavation by mechanical means(hydraulic excavator)/manual means in Soft rockin foundation, trenches etc. including shoring, shrutting wherever required bailing/pumping of water, leveling the bottom of excavation and refilling selected excavated materials and consolidating in the sides of foundation and disposing the surplus materials atplaces as directed within a lead of 2 Kmsall as per drawings and specifications. |
| 5 | Earth work excavation by mechanical means(hydraulic excavator)/manual meansin hard rock by chiselling (blasting prohibited) in foundation, trenches etc. including shoring, shrutting wherever required bailing/pumping of water, leveling the bottom of excavation and stacking the excavated material at places as directed within a lead of 2 kms as per drawings and specifications (Only stack measurement will be made and paid for) |
| 6 | Providing Pre-construction anti-termite treatment using chlorpyriphos emulsifiable concentrate 20 % with 1 % concentration as perspecifications.Note: The contractor shall furnish from the agency carrying out this work under this item a written guarantee in favour ofNPCIL for the satisfactory performance of the treatment for a period of ten years. |
| 7 | Filling with selected earth in layers of not more than 150 mm thick compacted layer, each layer well rammed, watered and consolidatedall as per drawings and specifications. |
| 8 | Selected earth brought from 50 m lead (from item No:1) |
| 9 | Selected earth brought from withina lead of 2 Km (Including excavation soil as directed) |
| 10 | Providing and filling withcrushed sand as approvedand as per drawings and specifications |
| 11 | Providing, laying, spreading and compacting graded stone aggregate (size range53 mm to 0.075 mm)to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with suitable mechanized vibrator to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge,as per clause 406 of MORT & H specifications complete in all respects. |
| 12 | Providing and laying plain cement concrete 1:4:8 using 40 mm and down graded stone aggregateat all height including mechanical mixing, leveling, compaction, vibrating,finishing smooth the exposed surfaces of concrete, curing etc complete as per drawings and standard specifications. |
| 13 | Providing and laying plain cement concrete 1:2:4, using 20 mm and down graded stone aggregateat all height including mechanical mixing, leveling, compaction, vibrating, finishing smooth the exposed surfaces of concrete, curing etc complete as per drawings and standard specifications. |
| 14 | Providing and laying M30 Design mixconcrete with cement content up to 350kg/Cum using 20mm and down graded stone aggregates, admixturesincluding Mixing ,Ramming, Compaction, leveling, curing, placing at all lifts, including scaffolding and Finishing smooth all exposed faces complete as per specification. |
| 15 | Adjustment of cement used less/more than the specified quantity |
| 16 | Providing ,placing in position and removing Form work for all insitu concrete works includingscaffolding etc., complete at all elevations as per drawing and specification (measurement for form work shall be the area of forms in contact with concrete surfaces) |
| 17 | Supply and Fixing in position 25mm thick Cement bonded Particle board (Bison board) of brands NCL/Hindustan Plywood Co/Ramco/Everestand required sizesfor wardrobe shelves. The cost inclusive of material, labour, tools & tackles includingFixing the board on the brickwall/concrete area bychipping the area for proper recess to fix the board in position and finishing the edgessmooth etc completeas per drawings and specifications |
| 18 | Providing cutting ,bending placing and tying mild steel, high yield steel reinforcementin RCC works including providing spacer blocks in CM 1:2, binding wires etc.complete at all elevations as per drawings and specifications including dewatering wherever necessary etc complete as per drawings and specifications |
| 19 | Cement Concrete Block Masonry works |
| 20 | Providing and constructing cement concrete block masonryof minimum M5 grade conforming to IS-2185 of latest version , using solid blocks ofspecified size (400mmx200mmx200mm) ,in cement mortar 1:4 by volume,for walls below plinth and locations includingracking out joints, curing etc complete as per specification |
| 21 | Providing and constructing cement concrete block masonryof minimum M5 grade conforming to IS-2185 of latest version , using solid blocks ofspecified size (400mmx200mmx200mm) ,in cement mortar 1:4 by volume, for walls in super structure for all locations and elevations including scaffolding, racking out joints, curing etc completeas perdrawings and specifications |
| 22 | Providing and constructing 100mm thick cement concrete block masonryof minimum M5 grade conforming to IS-2185 of latest version , using solid blocks ofspecified size (400mmx200mmx100mm) ,in cement mortar 1:4 by volume, including providing 40mm thick Cement Concrete 1:2:4 at every third layer, for partition wallsat all elevations and locations including scaffolding, racking out joints, curing etc complete as per specifications and drawing |
| 23 | Plastering of external faces of brick work/concrete (using M.Sand/Crushed sand) at all elevations in cement mortar 1:4, 20 mm thick including scaffolding, curing, forming grooves, plaster bands, border, keystone etc wherever required allas per drawings and specifications |
| 24 | Providing cement plaster for the internal faces of brickwork / concrete (using M.Sand/Crushed sand)at all elevations in cement mortar 1:5, 12mm thick, finished smooth with a floating coat of neat cement including scaffolding, finishing, curing,forming grooves wherever necessary all completeas per drawings and specifications |
| 25 | Providing cement plaster for the ceiling (using M.Sand/Crushed sand)with 6 mm thick in cement mortar 1:3 at all elevations including hacking and preparing the surface, scaffolding, finishing,curingetc all completeas per drawings and specifications |
| 26 | Providing sand faced/plain water proof cement plaster 20mm thick in cement mortar 1:3 (using M.Sand/Crushed sand) mixedwith waterproofingcompound FOSROC/ROFF/Dr.Fixit/SIKA/BASF/Bostic make, at 3% by weight of cement used or as per manufacturers specifications including finishing with a floating coat of neat cement, scaffolding, curing as per drawings and specifications |
| 27 | Providing and applying Hybrid Polyurethanespray over the preparation by applying epoxy putty in to pin holes exposed during grinding of the existing concrete surface and subsequently application of approved primer of Master seal P2525 from M/s. BASF or Top Prime ER40 of CONFIX INDIA. The Hybrid Polyurethane coat of ZIPPROOF SFU 140 of CONFIX INDIA or Masterseal M800 - Part A & Part B of BASF Or FOSROC Or PIDILITE Or HUNSTMAN Makes as a specially designedplural component with high pressure Two component spraying machine at specifiedDry Film Thickness of 2000 micron as per manufacture\"s specifications including grouting wherever required by polyurethene injection high strength resin Top injekt 70 and as directed by the Engineer-in-charge. |
| 28 | Supply and laying one course of pressed cement tiles 20 mm thick of 250mmX250mm size as per IS:1237 of latest version,laid over the roof slab overa base of 20mm thick CM 1:4 and joints pointed neatly in cement mortar 1:3 mixed with water proofingadmixture of approved make etc complete allas per drawings and specifications |
| 29 | Water tank Inner water proofing works using Polyurea systemproductive coating of 1500 micronwith the following working procedure: The inner surface of water tank found any cracks and pin holes are to be filled with epoxy putty. The prepared surface shall be applied with Polyurethane primer and top coat shall be applied with Polyurea of Polyroof PW Confix India make Or FosrocOr Piditite Or Huntsman makes for internal coating of portable water by spray system, the material shall be 100% solid of two component and rapid curing pure Polyurea system as a water proofing and productive coating of 1500 micron to be applied as per manufactures specification.The top coat shall be seamless coating which shall ensure very long life cycles and high durability. The product shall be fast setting and based on elastomeric water proof coating for clean water. The top coat of Polyurea shall confirm the following technical parameters.Solid-100 %, Tensile strength - 26.2 mpa,Tear Resistance-73.6 N/mm,Shore A hardness-90,Shore D hardness – 43,Elongation %-420 %,Solid Content-100%,Abrasion Resistance-45 mg/1000 cycles,Crack Bridging Capacity – PassThe rate shall be inclusive of deployment of man power such as specialized applicator / operator including necessary tools, tackles, machineries, scaffolding, consumables etc., to complete the entire work as per the requirement of Engineer-in-charge. |
| 30 | Providing and Fixing in position vitrified (Soluble salt) floor/skirting tilesof JOHNSON/ SOMANY/ REGENCY/NITCO/BELL/ KAJARIA/ AGL/CERA/SIMPOLA/HSIL/VERMORA/BONZER7/PAVIT make of size not less than 600x600 mm, thickness not less than 8mm of approved coloursas per the design including setting in cement mortar 1:4, 20 mm thick base layer, pointing the joints neatly with white cement with pigment to match with tiles,allas per drawings and specifications |
| 31 | Providing and Fixing in position ceramic glazedfloor tiles (Anti-skid) of size 300 x 300 mm as specified below (thickness to be specified by the manufacturer) of premium quality confirming to IS-15622 of JOHNSON/ SOMANY/ REGENCY/NITCO/BELL/ KAJARIA /AGL/CERA/ SIMPOLA /HSIL/ VERMORA/ BONZER7/PAVIT make, in all colours and shades except White, ivory, Grey, Fume red and Brown laid on 20mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) including pointing the joint with white cement and matching colour pigment etc at all floors complete all as per drawings and specifications |
| 32 | Providing and Fixing in positionceramic glazedwalltiles of size 300 x 450 mm (thickness to be specified by the manufacturer) of premium quality confirming to IS-15622 of JOHNSON/ SOMANY/ REGENCY/NITCO/BELL/ KAJARIA/AGL/ CERA/SIMPOLA /HSIL/VERMORA/BONZER7fixing over tile fixing adhesive of Dr.Fixit fevimate XL or other approved makesas per manufacturers specifications including pointing the joint mixed withcolour pigment of matching shade etc complete at all floors/levels etcas per drawings and specifications |
| 33 | Providing and Fixing 20mm thick Exterior grade designer tilesof approved colour and design over 20mm thick base cement mortar 1:4 laid and pointed with white cement slurry mixed with pigments to match with the shade of the tileincluding rubbing, curing, in Staircases (both tread & riser), Walkway areas, Entrances etc.,as per drawings and specifications |
| 34 | Providing and laying20mm thick (+-2mm)polished Natural granite slab of approved colour\" Cherry Red\",for flooring /wall cladding/skirtingand other surfaces as directedwith all exposed surfaces buffed, making half/full round nosing, set over a base of cement mortar 1:4, 20 mm thick neatly pointed with white cement and colouring pigmentsto match the shade of the stone as per the requirement, curing, rubbing, polishing, etc completeas per drawings and specifications |
| 35 | Providing and laying M30 grade 60 mm thick interlocking precast concrete pavers blocks as pr relevant IS of approved shape over a profiled layerto the required line, pattern etc., allas per drawings and specifications |
| 36 | Providing, fabricating and erection of Structural steel members made out of M.S. angles, flats, plates, pipes, channels, tubes, rods etc conforming to relevant ISetc., includingcost of welding, welding rods, drilling holes, bolts/nuts wherever required and providing and applying two or more coats of approved quality synthetic enamel paint over a coat ofzinc chromate yellow primer etc., as per drawings and specifications |
| 37 | Supply and Fixing in position approved quality Stainless Steel of Grade-304 for handrails/other areas as directedusing SS pipes/tubes/balls etc including chasing the walls/floor for Fixing in position and filling the area by cement concrete 1:2:4, finishing with cement plaster in CM 1:4 etc completeas per drawings and specifications |
| 38 | Providing and Fixing Powder coated (50 micron black or bronze) Aluminium doors, hinged / sliding windows & ventilators and partitions with extruded built up standard tubular and other sections of approved make conforming to IS:733 and IS:1285 powder coated to the required shade, fixed with rawl plugs and screws or with Fixing clips or with expansion hold fasteners including filling up of gap at junctions, at top, at bottom and sides with required PVC / Neoprene felt etc, aluminium sections are smooth rust free, straight, mitered and jointed mechanically wherever required, sections are prepared to receive the glass or particle board of specified thickness, including aluminium snap beading, CP brass / stainless steel screws, providing and Fixing all powder coated fixtures and fittings all complete as per drawings and specifications |
| 39 | Providing and Fixing12mm thick plain glazing, Modi guard/Saint Gobain/Hindustan/ Borosil/Asahi India/La Opala RG Ltd make for aluminium doors fixed glazing, withPVC/neoprene gasket, aluminium snap beading etc.all complete as per drawings and specifications (Cost of aluminium snap beadings will be paid in Aluminium item). |
| 40 | Supply and Fixing of Both side laminated Board of 12 mm thick IS make of approvedcolour as specified forAluminum door with necessary tools, tackles, men, material etc., complete |
| 41 | Providing and Fixing double action floor springs of Everest/KBD/Kadson/ Core/Dorset/Geze/ Ozone/Archis/Opel/ makeconforming to IS 6315 for aluminium doors including cost of cutting floor as required embedding in floor and cover plates etc complete as per drawings and specifications |
| 42 | Supplying and fixing in position single leaf Factory made flush door shutter,Frame of size 100mm size facing sheet & locking framing 75mm x 50mm and shutters of 25mm thick (Coloured frame and shutter) using PVC integral foam sheet . The PVC Integral Foam shall be factory manufactured solid section of light weight sheet with fine & homogeneous closed cell structure with smooth, glossy, hard surface finish on both sides. The sheet shall have density of 500 - 600 Kg/Cum, water absorption less than 1% and tensile strength greater than 11 MPa. PVC integral form sheet shall be of M/s. Jain Irrigation Systems Ltd. (Ex-cel sheet) Or M/s SNG ECO India Or M/s Straton Integral PVC Form makes of approved colour forflush door shutter including providing recessions for hinges, fixing with following fittings over the PVC solid door frame using required fasteners,cutting the sheets for required dimentions, jointing the same, finishing all edges with mixture of PVC powder & solvent for smooth finish, etc., all complete as per specification and as directed by the Engineer-In-Charge.The door shutter shall be fixed with the following hardware fittings: -a)3 Nos. of 75 mm long stainless steel butt hingeswith suitable stainless steel screws.b) Two numbers of 125mm long SS Handle with suitable CP screws.c) Two numbers of 100mm long SS tower bolt with suitable CP screws. |
| 43 | Supplying and fixing in position single leaf Factory made flush door shutter (Toilet doors), frame of size 75mm x 36mm and shutters of 18mm thick (Off white colour frame and shutter) using PVC integral foam sheet . The PVC Integral Foam shall be factory manufactured solid section of light weight sheet with fine & homogeneous closed cell structure with smooth, glossy, hard surface finish on both sides. The sheet shall have density of 500 - 600 Kg/Cum, water absorption less than 1% and tensile strength greater than 11 MPa. PVC integral form sheet shall be of M/s. Jain Irrigation Systems Ltd. (Ex-cel sheet) Or M/s SNG ECO India Or M/s Straton Integral PVC Form makes of approved colour forflush door shutter including providing recessions for hinges, fixing with following fittings over the PVC solid door frame using required fasteners,cutting the sheets for required dimentions, jointing the same, finishing all edges with mixture of PVC powder & solvent for smooth finish, etc., all complete as per specification and as directed by the Engineer-In-Charge.The door shutter shall be fixed with the following hardware fittings: -a)3 Nos. of 75 mm long stainless steel butt hingeswith suitable stainless steel screws.b) Two numbers of 125mm long SS Handle with suitable CP screws.c) Two numbers of 100mm long SS tower bolt with suitable CP screws. |
| 44 | Providing and Fixing heavy duty hydraulic door closers of SHUTWELL/OPEL/KBD/KADSON/CORE/DORSET/GAZE/OZONE/ARCHIS/DYNA/EVERESTmakes confirming to IS 3564 for doors including the cost of required tools, labour etc complete as per specifications |
| 45 | Providing and Fixing factory made UPVC white colour casement/sliding window using extruded profiles. Profiles of frames and sash will be mitered cut and fusion welded at all corners, including drilling of holes for Fixing hardware and drainage of water etc., making arrangement for Fixing of hardware, EPDM gasket, 1.2 ± 0.2 mm thick galvanised steelprofile to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100 mm long fasteners and other fixturs, joint filling using polysulphide sealant etcall complete as per drawings and manufacturers specifications |
| 46 | UPVC Sliding window glazed with 5mm thick glass shutter and Aluminium mosquito mesh shutter |
| 47 | UPVC Louvered window with 5mm thickglass and Aluminium mosquito mesh shutter |
| 48 | Providing and applying Acrylic Emulsion paintofAsian paints (Premium Emulsion)/Lewis Berger (Rangoli) /ICI Dulux (Super smooth)/Matex gold of Nippon/Nerolac make of approved shade in two or more coats over a coat ofprimerincluding preparation of surface with required coats of putty using Birla/ JK make, sand papering etc., toget good finish at all elevations etc all as peras per drawings and specifications |
| 49 | Providing and applying Exterior Emulsion Paint ofApex of Asian paints/Weather cote of Lewis Berger /Weather shield of ICI Dulux/Sumo Xtra of Nippon/Nerolacmake& shade in two or more coatsto give an even shade over a coat of primeras per manufacturer\"s instructions to the external plastered surfaces including preparation of surfaces, scaffolding etc. at all elevations, completeas per drawings and specifications |
| 50 | Providing and application of Bitumen Painting using approved quality bitumen paint in two coats over RCC footings, stub columns and beams etcas per drawings and specifications |
| 51 | Providing and Fixing in position over doors and windows approved make MS powder coated curtain rods of 25mm dia of approved colour includingproviding necessary decorative end fittings and wherever necessary intermediated support to be provided if width is more including providing required nos. of curtain hanging PVC hooks, necessary screws rawl plugs etccompleteas per drawings and specifications |
| 52 | Providing and Fixing in position 24 guage G.I. Chicken mesh of 150 mm wide in between the junction of column/beams with masonry by placing the mesh with nailingetc before at all elevations etc completeas per drawings and specifications |
| 53 | Supplying & Fixing in position suspended Gypsum board False ceiling using 12mm thick Gypboard as per IS:2095 and side cladding with anodised aluminium frame workusing anodised aluminium sections, with adjustable GI rods, holding cleats grid work suitably modified along the walls and beams, fixed with anchor bolts, making extra frame work around the Air conditioning and electrical fixtures and fittings fixed with necessary clips etc. complete as per drawings andspecifications |
| 54 | Adjustment of cement used less/more than the specified quantity |
| 55 | Providing and Fixing semi unitized structural glazing fixed / openable(glazing visible from exterior surface) using 6mm thick heat strengthened reflective type glass of Modi guard/Saint Gobain/Hindustan/Borosil/Asahi India/La Opala RG Ltd/AIS make and approved shades with frame work using extruded anodized Aluminium section (20 micron) of approved shade with sub frame system using JINDAL / INDAL / HINDALCO make of approved size, including making necessary opening arrangement in the openable area , Fixing the Aluminium grid work in to the masonry / RCC with necessary fastening materials such as SS brackets, Anchor fasteners, cleats, nuts, bolts, rivets, washers, including fixtures required for Fixing glass such as double side adhesive tape, silicon sealant (Dowcorning), weather strip, weather sealant etc., at all elevations with necessary scaffolding arrangements etc all as per drawings and specifications :: Note: (i) The contractor shall submit the design for aluminium grid work for structural glazing with parameters such as wind pressure 200kg/ M2, necessary seismic loads as per relevant code of practices. Weight of Aluminium grid work shall not be less than 7.5kg/Sq. Meter with arrangements for arresting rain water and the same shall be approved by Engineer in charge before taking up the work.(ii) The rate is inclusive of design; preparation of supporting drawings, all material, labour, scaffolding etc., the measurement will be paid as per the finished area. |
| 56 | Providing and Fixing Tray type Aluminium composite panel cladding, using Alucomat / Alucobond/Durabuild brand at all elevations of approved colour with standard section of 4mm thick aluminium composite panel claddingconsisting two skins of 0.5mm thick aluminium and 3 mm sandwich polyethylene core, PVDF coating with protective film on front side, mill finish on rear side as per manufacturer\"s specification. Shop drawings for the cladding frame arrangement shall be submitted by the contractor and the same to be approved by the Engineer - in – charge. The rate includes cost for all materials, complete staging, scaffolding, application of sealant ,frame work made up ofextruded anodized aluminium sectionsand structural steel with two coats ofapproved quality synthetic enamel paint over a coat of primer, preparation and submission of shop drawings for approval etc., complete in all respects as per drawings and specifications |
| 57 | Dismantling the existing Brick masonry at all levels including required scaffolding , tools, labours, disposal of unserviceable materials up to a lead of 2.00 Km etc completeas per drawings and specifications |
| 58 | Providing and laying brick bat coba made in the proportion of 1:2.5 (1 part of slaked lime, 2.5 parts of 20mm minimum size broken burnt clay brick jelly)filling in sunken floors including beating, consolidating, mixing, compacting, finishing, curing all completeas per drawings and specifications |
| 59 | Providing and Fixing in position approved vitreous chinaware orissa pattern Water Closet 580 mm x 440 mmCera/Nycer/ Parrywaremake with \"S\" or \"P\" trap with all jointing materials including excavation, making hole in masonry, reconstructing the same, encasing the pan and trap with brick jelly concrete 1:2:4 and finishing the same etc., completeas per drawings and specifications |
| 60 | Supply |
| 61 | Fixing |
| 62 | EWC Wall Hung |
| 63 | Supply |
| 64 | Fixing |
| 65 | Providing and fixing PVC flushing cistern of 10 litres capacityCera/ Nycer/Parryware\" make with all syphonic fittings, including assembling the cistern components and flush pipe, testing etc., Complete all as per specifications etc complete as per drawings and specifications. |
| 66 | Supply |
| 67 | Fixing |
| 68 | Providing and Fixing in position porcelain oval shape white colour counter sunk wash basin ofCera/Nycer/Parrywaremake on Marble/Granite counteras per drawings and specifications(Item of marble/granite will be paid under relevant item). |
| 69 | Supply |
| 70 | Fixing |
| 71 | Providing and fixing PTMT symet waste coupling -32mm dia half threaded for wash basin of Prayag/Polytuf/Wavin Vectus/King pipes/Polo India/Plasto make with rubber plug ball chain with necessary check nut as per drawings and specifications. |
| 72 | Supply |
| 73 | Fixing |
| 74 | Providing and Fixing heavy quality PTMTbottle trap as per IS-9763 of Prayag/Polytuf/Wavin Vectus/King pipes/Polo India/Plasto make of self cleaning design for wash basin. - 32 mm nominal bore |
| 75 | Supply |
| 76 | Fixing |
| 77 | Providing and Fixing 15 mm size heavy quality CP brass pillar cock easy clean type as per relevant ISfor wash basin with capstan head Adson/Cera/Parrywaremake as per drawings and specifications |
| 78 | Supply |
| 79 | Fixing |
| 80 | Providing and Fixing heavy quality 15mm dia CP brass angle cock as per relevant IS,Adson/Cera/Parrywaremake as per drawings and specifications |
| 81 | Supply |
| 82 | Fixing |
| 83 | Providing and Fixing heavy quality 15 mm dia, CP brass screw down long bodied bib tap with CP brass flanges as per relevant IS,Adson/Cera/Parrywaremake as per drawings and specifications |
| 84 | Supply |
| 85 | Fixing |
| 86 | Providing and Fixing 15mm dia CP brass screw down stop cock concealed type with female ends as per relevant IS,Adson/Cera/Parrywaremake as per drawings and specifications |
| 87 | Supply |
| 88 | Fixing |
| 89 | Providing and Fixing heavy quality CP brass shower rose15 mm x 50 mm easy clean type with ball and socket arrangement as per relevant IS, Adson/Cera/Parryware make with CP shower arm of 300 mm length with CP flange as per drawings and specifications |
| 90 | Supply |
| 91 | Fixing |
| 92 | Providing and fixing white glazed vitreous china recess type toilet paper roll holder of size 200 x 100 mm with CP rod,\"Parry ware /Cera/Adson\" make including making necessary chases in wall for fixing and making good the same complete. |
| 93 | Supply |
| 94 | Fixing |
| 95 | Providing and Fixing C.P. brass three pronged robe hooks ofAdson/Cera/Parrywaremake with C.P. brass flange as per drawings and specifications |
| 96 | Supply |
| 97 | Fixing |
| 98 | Providing and Fixing in position mirror of size 600 x 450mm, made of Indian glass 6mm thick manufactured by Modi guard/Saint Gobain/Hindustan/Borosil/ Asahi India/La Opala RG Ltd make factory silvered with PVC backing 4mm thick etc., completeas per drawings and specifications |
| 99 | Supply |
| 100 | Fixing |
| 101 | Providing and Fixing of 600 mm x 20 mm CP brass towel rod of Adson/Cera/Parrywaremake,with a pair of CP brass brackets and wall flanges fixed to wall with CP brass screws screwed on to wooden plugs embedded in wall etc., completeas per drawings and specifications |
| 102 | Supply |
| 103 | Fixing |
| 104 | Providing and Fixing 15 mm dia PVC inlet connections to withstand temperature up to 600 C of\"Kohinoor/Prayag/ Adson/water tec\" make with heavy PVC check nut at both ends of length not exceeding 450 mm as per drawings and specifications |
| 105 | Supply |
| 106 | Fixing |
| 107 | Providing and Fixing in position white vitreous china flat back lipped front urinal basin of size 430 x260 x 350 mm with integral flushing rim Cera/Nycer/Parryware CI concealed brackets including CP brass spreader ofCera/Nycer/ Parrywaremake with complete fittings including painting of bracket etc., completeas per drawings and specifications |
| 108 | Supply |
| 109 | Fixing |
| 110 | Providing and Fixing in position Hindware/Cera /Nycer/Parryware/ Prayag/Johnson/Somanymake of Urinal division plate of700x340x120mm size as per manufacturers specification andas per drawings and specifications |
| 111 | Supply |
| 112 | Fixing |
| 113 | Providing and Fixing polyethylene - Aluminium polyethylene (PE-AL-PE) composite pressure pipe UV stabilized with carbon black confirming to IS:15450-2004 for water Supplyincluding providing and Fixing box clamps at 1000mm spacingfor external works and laying under floor wherever required and cutting the walls for required depth for concealed installation including cutting charges and making good the walls for internals and providing and Fixing all the required specials/fittings etc wherever required at all elevations including cost of scaffolding etc. completeas per drawings and specifications (Earthwork excavation will be paid under relevant item) |
| 114 | 12-20mm dia |
| 115 | Supply (Pipe with required specials as required) |
| 116 | Fixing |
| 117 | 16-20mm dia |
| 118 | Supply (Pipe with required specials as required) |
| 119 | Fixing |
| 120 | 20-25mm dia |
| 121 | Supply(Pipe with required specials as required) |
| 122 | Fixing |
| 123 | 25-32mm dia |
| 124 | Supply (Pipe with required specials as required) |
| 125 | Fixing |
| 126 | 32-40mm dia |
| 127 | Supply (Pipe with required specials as required) |
| 128 | Fixing |
| 129 | 42-50 mm dia |
| 130 | Supply (Pipe with required specials as required) |
| 131 | Fixing |
| 132 | Providing and Fixing isolating composite Brass Ball valve \"Akar/Zolato/Leader\" make with compression type integral seal end connection suitable for PE-AL-PE composite piping system as per IS-15450, suitable for hot and cold water Supply as per drawings and specifications |
| 133 | Isolating composite Brass Ball valve - 40x40mm (Suitable for 3240composite pipe) |
| 134 | Supply |
| 135 | Fixing |
| 136 | Isolating composite Brass Ball valve - 32x32mm (Suitable for 2532 composite pipe) |
| 137 | Supply |
| 138 | Fixing |
| 139 | Providing and Fixing in position at all elevations PVC pipes ofPrince/Jain/ Kitec/Finolex/Supreme makeof Type-Bconforming to IS 13592 of latest version and specials such as bends, junctions with or without doors, cowls, etc., for soil, waste, vent or anti-syphonage pipes & for under floors etc with necessary clamps and wooden packing pieces at minimum 1 m spacing etc complete as per drawings and specifications |
| 140 | 32mm |
| 141 | Supply |
| 142 | Fixing |
| 143 | 40mm |
| 144 | Supply |
| 145 | Fixing |
| 146 | 75mm |
| 147 | Supply |
| 148 | Fixing |
| 149 | 110mm |
| 150 | Supply |
| 151 | Fixing |
| 152 | Providing and laying under floor PVC pipes of Prince/Jain/ Kitec/Finolex/Suprememake as per IS-15328 of latest version and required specials for soil, waste pipesetc complete as per drawings and specifications(Earth work excavation will be paid under relevant item). |
| 153 | 110 mm dia |
| 154 | Supply |
| 155 | Fixing |
| 156 | 160 mm dia |
| 157 | Supply |
| 158 | Fixing |
| 159 | Providing, Fixing and testing PVC rain water pipes of 110 mm dia as per IS-13592 of Type A of Prince/Jain/ Kitec/Finolex/Supreme make with necessary fittings and fixtures, such as bottom shoe, PVC grating, GI clamps, screws/nails,wooden packing pieces at minimum 1 m spacing, cost inclusive of Fixing the shoes in brick masonry in CM 1:6 and plastering the same with CM 1:4 etc complete all as per drawings and specifications |
| 160 | Supply |
| 161 | Fixing |
| 162 | Providing and Fixing 32-40 mm dia PE-AL-PE pipe 400 mm long as per IS-15450, with 2 Male threaded coupler Fixing with Araldite coating for bonding with concrete, one for connecting inlet pipe line with the sleeve, one for connecting ball valve with the sleeve inside the service water tank and another one for middle of the sleeve for bondage purpose. |
| 163 | Providing and Fixing horizontal type high pressure ball cock of 40 mm dia \"Prayag\" make item code 155 OrPolytuf/Wavin Vectus/King pipes/Polo India/Plasto makewith required accessories like ball, rod, rubber washer and double check nut, all conforming to relevant IS etc complete as per drawings and specifications |
| 164 | Providing and Fixing single/multi PVC Nahani trap of self cleaning design with 75 mm dia outlet, Prince/Jain/ Kitec/Finolex/Supreme make as per relevant IS,Stainless steel Grating and including necessary cement concrete 1:2:4 for embedding and making good the floor, connecting the trap to the waste pipe, forming circular hole up to floor level and rendering smooth, grating etc.Complete as per drawings and specifications |
| 165 | Providing and Fixing best quality PVC 150 x 150 mm size square mouth Gully trap and 100 mm P type outlet, \"Supreme/Prince/Star/Finolex\" make as per relevant IS and constructing brick masonry chamber 300 mm x 300 mm internal size in 110 mm thick fly ash brick masonry in CM 1:5 usingfly ash bricksas per IS:12894, class designation : 5 from the approved manufacturer by NPCIL,with necessary excavation with bed of 100 mm thick cement concrete 1:4:8 (1 Cement : 4 coarse sand :8 graded stone aggregate of nominal size) for foundation and around the trap and plastering with CM 1:3 (1 cement : 3 fine sand) 15 mm thick on internal and external surfaces on top and up to 150 mm below ground level, finished smooth, curing providing and Fixing double seal CI cover and frame of weight not less than 7.0 kgs (as per relevant IS), at top etc completeas per drawings and specifications. (Earth work excavation will be paid under relevant item.) |
| 166 | Construction of inspection chambers of internal clear dimension 450 x450 up to a maximum depth of 600mm in 230 mm thickfly ash brick masonry in CM 1:6usingfly ash bricksas per IS:12894, class designation : 5 from the approved manufacturer by NPCIL, over a bed of 150mm thick 1:4:8 cement concrete foundation, plastering with CM 1:4, 20mm thick on inside, outside and all exposed surface finished with floating coat of neat cement, PCC 1: 2:4 for benching and channel finished with neat cement,Top covered with100mm thick RCC 1:2:4 grade slab with required steel reinforcements, , including providing & Fixing double seal C.I. manhole cover & frameof 450x 450mmweight not less than 38 kg (as per relevant IS),embedding the C.I. frame in RCC cover slab etc completeas per drawings and specifications. (Earth work excavation and steel reinforcement will be paid under relevant item) |
| 167 | Construction of inspection chambers of internal clear dimension 900 x600 mmup to a maximum depth of 900 mm in 230 mm thickfly ash brick masonry in CM 1:4, usingfly ash bricksas per IS:12894, class designation : 5 from the approved manufacturer by NPCIL, over a bed of 150mm thick 1:4:8 cement concrete foundation, plastering with CM 1:4, 20mm thick on inside, outside and all exposed surface finished with floating coat of neat cement, PCC 1:2:4 for benching and channel finished with neat cement, providing and Fixing C.I. steps weighing not less than 3.5 Kg/each at 300 mm centre to centre etc., Top covered with100mm thick RCC 1:2:4 grade slab with required steel reinforcements,, including providing & Fixing double sealC.I. manhole covers & frames of size 600 x 450mm of weight not less than 50 kg (as per relevant IS),embedding the C.I. frame in RCC cover slab etc complete as per drawings and specifications(Earth work excavation and steel reinforcement will be paid under relevant item) |
| 168 | Extra depth for above item, for depth beyond 900 mm, 300mm or part there of including providing and Fixing CI steps weighing not less than 4.5 kg/each etc, as per specifications |
| 169 | Construction ofInspection chambers of internal clear dimension 1200 x 1000 x 1000 mm deep in 230 mm thickfly ash brick masonry in CM1:6,usingfly ash bricks as per IS:12894, class designation : 5 from the approved manufacturer by NPCIL,over a bed of 150mm thick 1:4:8 cement concrete foundation, plastering with CM 1:4, 20mm thick on inside and all exposed surfaces, providing and Fixing C.I. steps weighing not less than 3.5 Kg/each at 300 mm centre to centre etc., Top covered with100mm thick RCC 1:2:4 grade slab with required steel reinforcements, including providing & Fixing CI manhole cover & frame of 600 x 600mm ( double seal) of weight not less than 110 kgs (as per relevant IS), embedding the C.I. frame in RCC cover slabetc completeas per drawings and specifications(Earth work excavation and steel reinforcement will be paid under relevant item) |
| 170 | Extra depth for above item, for depth beyond 1000 mm, 300mm or part there of including providing and Fixing CI steps weighing not less than 4.5 kg/each etc, as per specifications |
| 171 | INCOMER PANEL: Main Power panel (MPP) - Supply and erection of Indoor Main Power panel (MPP) as per specification: (Refer Section-V)Incomer:- 400A TP+N 36KA TM Based MCCB+Handle+Spreader - 1SET, R,Y,B Phase Indication LEDLamp - 1 Set, Digital multi function meter-1 Set,400/5A CT - 3 No\"s, 6A 4P Control MCB - 1 NO. Outgoing:400A TPN SFU+Handle+ spreader - 1 No\"s. 250A TP+N 25 KA TM Based MCCB+Handle+ spreader - 3 No\"s.125A TP+N 16 KA TM Based MCCB+Handle -4 No\"s. 63A TP+N 16 KA TM Based MCCB+Handle -4 No\"s. Busbar Size: Phase & Neutral: 1Rx50x06MM Copper, Earth : 25x03MM Copper |
| 172 | Main Lighting panel (MLP) - Supply and erection of Indoor Main Lighting panel (MLP) as per specification:(Refer Section-V)Incomer:- 250A TP+N 25KA TM Based MCCB+Handle+Spreader - 1SET, R,Y,B Phase Indication Lamp - 1 Set, Digital multi function meter - 1 - 1 Set,250/5A CT - 3 No\"s, 6A 4P Control MCB - 1 NO. Outgoing: 250A TPN SFU+Handle+ spreader - 1 No\"s.125A TP+N 16 KA TM Based MCCB+Handle+ Spreader – 3 No\"s.63A 4P,10 KA,C curve MCB - 5 No\"s.Busbar Size: Phase & Neutral: 1Rx30x06MM Copper, Earth : 25x03MM Copper. |
| 173 | Supply, installation, testing and commissioning of MRL type 15 passenger Lift ofmake KONE/OTIS/Mitsubishi suitable for 2 Floors ( G +1) as per specifications. Scope includesDesign, procurement, transportation, installation, commissioning, testing , gettingCEA clearence, providing lift licence and maintenance of Lift for one year after the acceptance by NPCIL. Required illumination to be provided in the lift shaft and necessary power supply arrangement for the lift as per specification is in the scope of NPCIL. |
| 174 | Supply ,Installation, Testing & commissioning of 51.5 Ton IVRF HVAC package indoorunits consisting of the following 1.3Ton -15 nos,4 Ton -6 nos & 8 ton -1Nos& outdoor units consisting of the following 22 HP Outdoor Unit IVRF-22 TCN (Double Compressor)-2Nos & 2.0 HP Outdoor Unit IVRF -20TC/TCN (Double Compressor) -1 Nos having features like low sound level, draw thru air flow configuration, 3 speed motors, rear return air filter galvanized heavy gauge panels, microprocessor control and wired LCD display unit with suitable GI Duct.(Make: Blue star/Daikin/Carrier). (Refer Section-V) |
| 175 | PDB : Supply and erection of 6 way three phase distribution board complete with interconnection Copper busbar, Neutral bar, Earth bar, top and bottom removable gland plates with knockout, and single door with the followingRCCB/MCBs with .63A 4P RCCB (30m A ) - 1 no, .20A/16ASP MCB - 15 Nos( 601309 model of Legrand/L&T/Havells)Scope includes construction of pedestal cubicle and supply of necessary electrical components, hardwares for fixing the panel etc. to complete the work in all respect. |
| 176 | LDB:Supply and erection of 8 way (4+24) Three phasedistribution board complete with interconnection Copper busbar, Neutral bar, Earth bar, top and bottom removable gland plates with knockout, and acrylicdoor with the following RCBO/MCBs with .63A 4P RCBO (30m A ) - 1 no, .20A/16A / 6ASP MCB - 20 Nos( 601309 model of Legrand/L&T/Havells) |
| 177 | Primary wiring :- For lighting, bulkhead fitting andexhaust fan points, supply and wiring for point with two + one (earth-green) runs of 1.5sq.mm (22/0.3)1100V grade FRLS insulated single core multi strand Copper conductorwire(without joint)drawninto the existing PVC conduit (inclusive of supplying and laying of PVC conduits while concreting), complete with angle / batten lamp holder or ceiling rose, 5 Amps modular typeLegrand Mylinc/ MK India /Schneider/Anchor panasonic/GM make switchincluding pulling the wire from existing switch box to lighting point through the conduit and connecting at bothends.(The box, grid plate and the cover plate for the switch has been covered elsewhere.). Allitems such as 1.5sq.mm (22/0.3)Copper FRLS insulated wire, 6 Amps switch, 3 Plate ceiling rose, hylam sheet for JBs, necessary electrical components for wiring works (wherever applicable) shall be supplied by the contractor as per the requirement, specification (Approximate length 13Mtr )(Refer Section-V) |
| 178 | Secondary wiring:- For lighting, 6A sockets supply and wiring for point with two + one (earth-green) runs of 1.5sq.mm (22/0.3)1100V grade FRLS insulated single core multi strand Copper conductorwire(without joint)drawninto the existing PVC conduit (inclusive of supplying and laying of PVC conduits while concreting), complete with angle / batten lamp holder or ceiling rose, 5 Amps modular typeLegrand Mylinc/ MK India /Schneider/Anchor panasonic/GM make switchincluding pulling the wire from existing switch box to lighting point through the conduit and connecting at bothends.(The box, grid plate and the cover plate for the switch has been covered elsewhere.). Allitems such as 1.5sq.mm (22/0.3)Copper FRLS insulated wire, 6 Amps switch, 3 Plate ceiling rose, hylam sheet for JBs, necessary electrical components for wiring works (wherever applicable) shall be supplied by the contractor as per the site requirement. (Approximate length 10.5Mtr ) |
| 179 | Power point wiring : 16A Power switch & sockets (2 switches+2 sockets in switch board) inseperate switchboard: Supply, installation of 16A, 5 pin socket & switch outletincluding supply of 16A 5 pin socket and SP switch modular type. Legrand Mylinc/ MK India /Schneider/Anchor panasonic/GM make(switch & socket separate type). One end of the earthing wire to be connected at the third pin of 16A socket and the another end to be connected at the earth bar in the Distribution Board. Scope includes supply of modular socket and switch,4 module GI box with base ,cover plate and accessories withpoint wiring of 3 runs of 4 sq.mm copper wire for 16A-6A , 6 in 1 socket. (Refer Section-V) |
| 180 | Primary point wiring for fan control including fixing of 6A switch,400W modular step type regulator,ceiling rose,wiring from switch to ceiling rose etc.(Refer Section-V) |
| 181 | 6A Power sockets (2 switches+2 sockets in switch board) inseperate switchboard: Supply, installation of 6A, 5 pin socket & switch outletincluding supply of 6A 5 pin socket and SP switch modular type. (switch & socket separate type). One end of the earthing wire to be connected at the third pin of 6A socket and the another end to be connected at the earth bar in the Distribution Board. Scope includes supply of modular socket and switch, GI box, with base ,cover plate and accessories withpoint wiring of 3 runs of 2.5 sq.mm copper wire 6A socket.(Make:Legrand Mylinc/ MK India /Schneider)(Refer Section-V) |
| 182 | Supply, installation and wiring of 3R x 4sqmm Cu for FRLS insulated each core multistrand with 1100V Copper wire, drawn into the existing PVC conduit (inclusive of supplying and laying of PVC conduits while concreting) from MCB DB to various switch boards as circuit mains and switch board to switch board looping. The termination shall be done by using crimping type Copper lugs of Dowells make, suitable modular type switch box supply by contractor scope.(Refer Section-V) |
| 183 | Tube light LED: Supplyand installation ofLED tube lightfitting 230V, 20W(Make:Havells/Crompton/Philips)(Refer Section-V) |
| 184 | Bulk head LED: Supplyand installation of 9W LED bulk head light fitting with lamp.(Make:Havells/Crompton/Philips)(Refer Section-V) |
| 185 | Supplyand installation of 36WLED recess lamp fitting (2x2 feet) (Make:Havells/Crompton/Philips)(Refer Section-V) |
| 186 | Flood light LED: Supply & Fixing of 100W Rectangular LED Flood Light (10000 lumens)with innovative thermal management and available in multiple optics and equipped with IP-66 protection. (Philips/bajaj/crompton/wipro) (Refer Section-V) |
| 187 | Flood light LED: Supply & Fixing of 150WLED Flood Light (18000 lumens)with innovative thermal management and available in multiple optics and equipped with IP-66 protection. (Philips/bajaj/crompton/wipro) (Refer Section-V) |
| 188 | Ceiling fan: Supply and installation of 1200mm sweep ceiling fan of make/modelCG high speed/GM/Orient summer king without regulator, including assembling, fixing,supplying and providing3 core x 1.0 sq.mm flexible Copper cable and connection between fan and the ceiling rose / Connector in the existing fan hook boxasper specifications. (Refer Section-V) |
| 189 | Exhaust fan: Supply, installation and commissioningof 300 mm sweep heavy duty energy saving Exhaust Fan of metal construction and elegant design with shutter.Energy saving models with CRNO laminations(make/modelAlmonard/CG high speed/Orient) (Refer Section-V) |
| 190 | Wall mounted fan:Supplyand installationof450mm(18\"\") ultra high speed metal body with metal blade(3 blades)heavy duty wall mountedfan(make: Almonard/Orient/Crompton) inbuilt speed control with pull rope(Refer Section-V) |
| 191 | Supplyand installation of Earthing with copperearth plate 600mm X 600mm X 3mm thick including accessories and providing masonry enclosure with cover plate havinglocking arrangement and water pipe of 2.7 meter long with charcoal/coak and salt etc. as required(Refer Section-V) |
| 192 | Supplyand Laying of 25mmx 5mm copper strip at 0.50 meter below groung level as strip earth electrode,including connection termination with nut , bolt, spring, washer etc. as required.( jointing shal be done by overlapping with 2 sets of brass nut bolt & spring washer spaced at 50mm. (Refer Section-V) |
| 193 | Supply of power cable1100 V, 3.5C x 300 sq.mm stranded compacted circular aluminum conductor, XLPE insulated, cores laid up, extruded PVC inner sheath, galvanised steel flat strip armoured and overall extruded PVC sheathed cable conforming to IS 7098(part1)/1988.(Refer Section-V) |
| 194 | Supply of power cable1100 V, 3.5 C x 150 sq.mmstranded compacted circular aluminum conductor, XLPE insulated, cores laid up, extruded PVC inner sheath, galvanized steel flat strip armoured and overall extruded PVC sheathed cable conforming to IS 7098(part1)/1988.(Make:KEI/Havells/Glosters)(Refer Section-V) |
| 195 | Supply of power cable1100 V, 4C x 35sq.mmstranded compacted circular aluminum conductor, XLPE insulated, cores laid up, extruded PVC inner sheath, galvanized steel flat strip armoured and overall extruded PVC sheathed cable conforming to IS 7098(part1)/1988.(Make:KEI/Havells/Glosters)(Refer Section-V) |
| 196 | Supply of power cable1100 V, 4C x 16 sq.mm stranded compacted circular aluminum conductor, XLPE insulated, cores laid up, extruded PVC inner sheath, galvanized steel flat strip armoured and overall extruded PVC sheathed cable conforming to IS 7098(part1)/1988.(Make:KEI/Havells/Glosters)(Refer Section-V) |
| 197 | Laying of PVC Insulated and PVC Sheathed /XLPE power cable of 1.1 KV grade of following size(upto 35 Sq mm) direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required (Refer Section-V) |
| 198 | Laying of PVC Insulated and PVC Sheathed /XLPE power cable of 1.1 KV grade of following size( 95 Sq mm to 185 sq mm) direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required(Refer Section-V) |
| 199 | Laying of PVC Insulated and PVC Sheathed /XLPE power cable of 1.1 KV grade of following size(185 Sq mm to 400mm) direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required(Refer Section-V) |
| 200 | Glanding and Termination (3.5C X300 Sqmm cable)LT cable .supply of double compression type nickel platedbrass cable glands Termination of cable at Panels using glands and lugs and drilling/ modification of necessary holes in gland plates, GI nut and bolts and necessary accessories/hardware required to complete the work as per specifications.(Refer Section-V) |
| 201 | Glanding and Termination (3.5C X150 Sqmm cable) LT cable .supply of double compression type nickel platedbrass cable glands Termination of cable at Panels using glands and lugs and drilling/ modification of necessary holes in gland plates, GI nut and bolts and necessary accessories/hardware required to complete the work as per specifications. (Refer Section-V) |
| 202 | Glanding and Termination of (4C X35 Sqmm cable) LT cable .supply of double compression type nickel platedbrass cable glands Termination of cable at Panels using glands and lugs and drilling/ modification of necessary holes in gland plates, GI nut and bolts and necessary accessories/hardware required to complete the work as per specifications. (Refer Section-V) |
| 203 | Water Heater: Supply and Installation of storage type water Heaters ofCapacity 25 liters with all accessories including chord wire and plug top, brackets etc. of approved make(Racold/Venus/havells)model suitable for working on 230V AC system all as per specification &as directed by the Engineer – in – charge(Refer Section-V) |
| 204 | Water cooler :Supply,installation,testing & commissioningof cross Field water doctor cum hot water dispenser cum normal water storage and cold water storage in single compact unit as per the specification (Refer Section-V)(UV Plus 6 NHC Online Purifier cum Normal, Hot & Cold Dispenser Flow rate : 100 Ltrs/hr)(Refer Section-V) |
| 205 | Supply of 11 Mtr, height Octagonal-Hot dip galvanised pole made of 3mm thick HT sheet, steel plate, along with base packets, Suitable Round arm brackets for mounting 4Nos150W LEDFlood light fitting, provisions of cable glanding & termination by ring type lugs foundation bolts etc. Supply of all hardwares and accessories areincluded in this scope. |
| 206 | Installation of 11 Mtr, height Octagonal-Hot dip galvanised pole.Scope includes 1) excavation of pole pits in hard soil, RCC concreting with M-20 mix, 2) Painting of poles with single coat of aluminum paint, pole numbering 3)Supply & Providing and installation of 100 mm GI bend, 1Mtrlength pipe for cable entryall as per Technical specification . |
| 207 | 6 MODULE: Supply & installation of concealed in wall mounting 6 Modular switch board with covered plate comprising. (Switches are covered in the Point wiring ) (Make: Legrand Mylinc/ MK India /Havells/Schneider/GM) all as directed by Engineer.(Refer Section-V) |
| 208 | 12 MODULE: Supply& installation of concealed in wall mounting 12Modular switch board with covered plate comprising. (Switches are covered in the Point wiring ) (Make: Legrand Mylinc/ MK India /havells/Schneider/GM) all as directed by Engineer.(Refer Section-V) |
| 209 | Fly catcher: Supply& installation of Fly catch machine(36W) operable in 230V AC. With 2 feet 18 W UV lamp 2 nos fiited with electronic choke (Make: Health guard/pest-o flash/Ibell) |
| 210 | UPS:Supply& installation of ONLINE UPS (10KVA) with battery bank |
| 211 | Providing and laying of 4 pair soild tinned copper 0.5mm dia telecommunication cable with PVC/Polyethylene insulation, individual pair, PVC sheath, drawn in the existing PVC conduit including identification of cables with feruals in both end.Recommended make:Delton/Havells/Finolex/Reliance |
| 212 | Providing and installation of 2x2 lines Modular Telephone wall Sockets (RJ11) which includes Providing of concealed type metal box to be installed in the wall including Providing and fixing of cover plates, hardware, dummy covers, etc of approved make for installtion of the modular sockets and termination of cable at both the ends. All Providing items involved in this shall be same. Recommended make Anchor/Legrand/cabtree |
| 213 | Supply and installation of Telephone krone modules,SS back mount frame.Installation with 100 Pair Telephone JB.(JB supply NPCIL Scope) also Concealing of the JB in the wall. Recommended Make: Krone |
| 214 | Supply and installation of Telephone krone modules,SS back mount frame.Installation with 50 Pair Telephone JB.(JB supply NPCIL Scope) also Concealing of the JB in the wall. Recommended Make: Krone |
| 215 | Supply and installation of Telephone krone modules,SS back mount frame.Installation with 20 Pair Telephone JB.(JB supply NPCIL Scope) also Concealing of the JB in the wall. Recommended Make: Krone |
| 216 | Supply and installation of Telephone krone modules,SS back mount frame.Installation with 10 Pair Telephone JB.(JB supply NPCIL Scope) also Concealing of the JB in wall. Recommended Make: Krone |
| 217 | Supply and laying of 100 pair armoured jelly filled pvc telephone cable.Recommended make:Delton/Havells/Finolex/Reliance |
| 218 | Supply and laying of 50 pair Unarmoured jelly filled pvc telephone cable.Recommended make:Delton/Havells/Finolex/Reliance |
| 219 | Supply and laying of 20 pair unarmoured jelly filled pvc telephone cable.Recommended make:Delton/Havells/Finolex/Reliance |
| 220 | Supply and laying of 10 pair Indoor telephone cable.Recommended make:Delton/Havells/Finolex/Reliance |
| 221 | Supply and installation of 20mm PVC Concealding Conduit with fittings for laying of 4 pair, 10 Pair & 20 pairTelephone cables.Recommended make:Precision/AKG/Diamond |
| 222 | Excavation and refilling for laying of 100 Pair Telephone Cable & HDPE Pipe laying for 6 core OFC cable. |
| 223 | Providing and laying of OFC Drop cable. Recommended make:TE/Molex/R&M/Krone |
| 224 | Supply and installation of Single Mode Pigtail. Recommended make:TE/Molex/R&M/Krone |
| 225 | Supply and installation of SC/SC Single Mode Duplex Fibre Optic Adapter. Recommended make:TE/Molex/R&M/Krone |
| 226 | supply and installation of Fiber optic terminal box for Junction of a 6core Fibre cable and 10 no\"s of Drop cables.. |
| 227 | supply and installation of 1 x 8 fibre Splitter |
| 228 | supply and installation of 10 x 12 PVC Junction BoX. |
| 229 | supply and laying of HDPE Pipe, Size:40 mm .Recommended make duraline/Jain irrigation/kriti India/gamson India/Aspra industries |
| 230 | supply and installation of Fibre face Plate. Recommended make Netlink/syrolink/Syrotech |
| 231 | Supply and Installation of 12 U Wall mount Rack with power strip and fan..Recommended make Rittal/Netrack/wallrack |
| 232 | Supply and installation of Cat 6 UTP cable with marking ferrules.Recommended make:Finolex / Molex /D Link |
| 233 | Supply and installation of 20mm PVC Concealding Conduit with fittings for laying of Cat 6 UTP cables.Recommended make:Precision/AKG/Diamond |
| 234 | Supply and installation of RJ 45 with connector cover. |
| 235 | Supply and installation of 12 Port Gigabite POE Switch |
| 236 | Supply and installation of IP Based Dome Camera . Specification 2MP resolution, 12mm lens, Dome fixed camera. Recommended make:Axis/Hikvision |
| 237 | Supply and Installation of Discussion Device Long, Table Top Mounting, 488mm Length Of The Microphone From The Base Of The Stem, 85dB SPL Nominal Acoustic Input, Microphone on/off button. Recommended make: Bosch/Shure/Studiomaster |
| 238 | Supply and Installation of Control Unit, Controls up to 50 Discussion units, loop length can be extended upto 200meter. For business discussions and small conferences,two to six microphones can be active simultaneously,with the chairman always having speaker priority.Recommended make: Bosch/Shure/Studiomaster |
| 239 | Supply and Installation of 12W Cabinet Loudspeaker,for indoor use, Rated Impedance833 Ohm,100V Rated Input Voltage. Recommended make: Bosch/Shure/Studiomaster |
| 240 | Supply and Installation of 16-Channel Professional Effects Mixer with USB Port, Onyx Mic Preamps and GigFX effects engine. ?1/4-inch Audio, USB, 3.5mm Audio, Headphone, ?16-Channel. Lay down your tracks in incredible 24-bit/ 192kHz quality for the cleanest recordings possible. |
| 241 | Supply and Installation of Mixer Amplifier, 240W, LCD display,USB port,UBS/BT keyboard functions with IR remote sensor, 240 watts of power and 6 microphone / line input plus 3 music source inputs. Recommended make: Bosch/Shure/Studiomaster |
| 242 | Supply and Laying of 2 core shielded microphone cable for concealding wiring, Recommended make:MX/Belden/Finoplex |
| 243 | Supply and Laying of Good Quality 2 core speaker cablefor concealding wiring. Recommended make: Belden/Finolex/Vguard |
| 244 | Supply and installation of 20mm PVC Concealding Conduit with fittings for laying of Speaker & Mic cable.Recommended make:Precision/AKG/Diamond |
| 245 | Supply and installation of Cable Raceway for Sidewalks or Walkways,Corduct, Cord Protector, Wire Organizer and Hider, Rubber Cable Cover and Concealer. Recommended make:C2G/Legrand/UT Wire |
| 246 | Supply and installation of PVC Trunking 75 X 50 Wiring Duct. High Quality Rigid Polyvinyl Chloride Material. Recommended make: MK/Rolycab/Betaduct. |
| 247 | Supply and Installation of 4000 luminous Projector DLP,High Brightness, 20000:1 High Contrast Ratio, Dual HDMI, Upto 15000 hrs Extra-Long Lamp Life, 10W Speaker, 3D Capable. Recommended make: Benq/EPSON/SONY |
| 248 | Supply and Installation of 8X6 Feet Motorized Projector Screen With Remote. Recommended make:Liberty/Logic |
| 249 | Supply and Installation of Ceiling mout kit for installation of Projector. Recommended make:Liberty/Logic |
| 250 | Supply and Installation of HDMI Cable 30mtr.Gold-Plated;Alloy Case Cable..Recommended make: Dlink/Belkin. |
| 251 | Supply, Installation, Testing and Commissioning of 2 Pole, AC 3 Phase /415 Volts /50HZ Terrace Level Centrifugal Monoblock Pump of discharge capacity 900 LPM@35 Mtr Head with Cast Iron Impeller, SS 410 Shaft with Mechanical seal, Class F Insulation, IP-55 Enclosure with suitable TEFVElectricMotor of capacity 9.30KW/12.50 HP of Make-KIRLOSKAR -Model No. KDI 1348. or equivalent make as approved by NPCIL with all required fittings, fixtures related to this work, tools, tackles, labour, consumables etc to complete the work |
| 252 | Supply, Installation, Testing and Commissioning of Terrace Level DOL Starter Panel suitable for the above pump-set. Make- WNTRACK Electricals Or Prathibha Engineering or equivalent make as approved by NPCIL with all required fittings, fixtures related to this work, tools, tackles, labour, consumables etc to complete the work |
| 253 | Supply and laying of 4 Core x 25 sqmm Aluminium ArmouredU/G Cables from the DOL Starter Panel to be located in the Terrace to Terrace level Pumpset with GI Earthing with Incoming Supply for the Fire fighting with all required fittings, fixtures related to this work, tools, tackles, labour, consumables etc to complete the work |
| 254 | Supply and Installation of Pressure switch of Indfoss or equivalent make as approved by NPCIL with all fixtures etc to complete the work |
| 255 | Supply and Installation of Bourdon Type Pressure Guage of 100 mm dia of Hebig / H.Guru or equivalent make as approved by NPCILwith all fixtures etc to complete the work |
| 256 | Supply, Installation, Testing and Commissioning of 100 MM DIA MS Pipeas per IS;1239 Part-I Heavy Grade with one coat of Zinc Anti-corrssivePrimer Paint and 2 coats of PO Red Synthetic Enamel paint along with suiable Heavy Grade MS Fitting such as MS Elbows, MS Reducers with all required fittings, fixtures related to this work, tools, tackles, labour, consumables etc to complete the work |
| 257 | Supply, Installation, Testing and Commissioning of 80 MM DIA MS Pipeas per IS;1239 Part-I Heavy Grade with one coat Primer Paint and 2 coats of PO Red Enamel paint along with suiable Heavy Grade MS Fitting such as MS Elbows, MS Reducers with all required fittings, fixtures related to this work, tools, tackles, labour, consumables etc to complete the work |
| 258 | Supply, Installation, Testing and Commissioning of 25 MM DIA MS Pipeas per IS;1239 Part-I Heavy Grade with one coat Primer Paint and 2 coaats of PO Red Enamel paint along with suiable Heavy Grade MS Fitting such as MS Elbows, MS Reducers with all required fittings, fixtures related to this work, tools, tackles, labour, consumables etc to complete the work |
| 259 | Supply, Installation, Testing and Commissioning of 100 MM DIA \" Y\" Type Strainer Double side Flanged with suitable MS Flanges, Insertion Ruubber Gasket and GI Bolts and Nuts with all required fittings, fixtures related to this work, tools, tackles, labour, consumables etc to complete the work |
| 260 | Supply, Installation, Testing and Commissioning of 100 MM DIA Butterfly valve PN-16 of Make- ZOLOTO/ AUDCO make with suitable MS Flanges, Insertion Ruubber Gasket and GI Bolts and Nuts with all required fittings, fixtures related to this work, tools, tackles, labour, consumables etc to complete the work . |
| 261 | Supply, Installation, Testing and Commissioning of 80 MM DIA Butterfly valve PN-10 of ZOLOTO/ AUDCO/Inter-valve makes with suitable MS Flanges, Insertion Ruubber Gasket and GI Bolts and Nuts with all required fittings, fixtures related to this work, tools, tackles, labour, consumables etc to complete the work . |
| 262 | Supply, Installation, Testing and Commissioning of 80 MM DIA Wafer Type Non-Retuen valve PN-10 of ZOLOTO/ Inter-valve make with suitable MS Flanges, Insertion Rubber Gasket and GI Bolts and Nutswith all required fittings, fixtures related to this work, tools, tackles, labour, consumables etc to complete the work . |
| 263 | Supply andInstallation ofMS First Aid Hose-Reel Drum of OMEX/ NEWAGE make as per IS:884 with Thermoplastic Hose of 30 metre long as per IS: 12585 Type-2 with PVC Nozzle with all required fittings, fixtures related to this work, tools, tackles, labour, consumables etc to complete the work . |
| 264 | Supply and Installation of MS Hose Box of size 9000xx800x300 mm depth to accomodate 1 No of First Aid Hose Reel Drum duly powder coated Red Out-side and White Inside Glass fronted with Rubber beading with locking arrangement and key holder on the front with all required fittings, fixtures related to this work, tools, tackles, labour, consumables etc to complete the work . |
| 265 | Supply and Installation of 25 mm dia ball Valve of ZOLOTO/LEADER make for Hose-Reel connection with all fixtures etc to complete the work |
| 266 | Supply and Installation of 25 mm dia Air Release Valve ofSANT or equilent make with all fixtures etc to complete the work |
| 267 | Supply and Installation of MS Channels, Angles etc for Pipe supports with all fixtures etc to complete the work |
| 268 | Manual Type Fire Extiguishers |
| 269 | Supply and Installation of 4 KG Capacity ABC Stored Pressure Fire Extinguisher as per IS: 15683 with ISI Mark.(Make- SAFEX/ EXCELLENT) with all fixtures etc to complete the work |
| 270 | Supply and Installation of 4.50 KG Capacity Co2 TYPE Fire Extinguisher as per IS: 15683 with ISI Mark.(Make- SAFEX/ EXCELLENT) with all fixtures etc to complete the work |
| 271 | Supply and Installation of 9 LITRE Foam Type Fire Extinguisher as per IS: 15683 with ISI Mark.(Make- SAFEX/ EXCELLENT) with all fixtures etc to complete the work |