Tender For Completion Of Balance Work For Construction Of Dwelling Units Includind Allied Services For Officers, Jco’S & Or’S At Pune (Army) & Lonavla (Navy), pune-Maharashtra

Military Engineer Services-MES has published Tender For Completion Of Balance Work For Construction Of Dwelling Units Includind Allied Services For Officers, Jco’S & Or’S At Pune (Army) & Lonavla (Navy). Submission Date for this Tender is 10-06-2024. Building Work Tenders in pune Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

43233233
Tender For Completion Of Balance Work For Construction Of Dwelling Units Includind Allied Services For Officers, Jco’S & Or’S At Pune (Army) & Lonavla (Navy)
Open Tender
Indian
Maharashtra
pune
10-06-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Completion Of Balance Work For Construction Of Dwelling Units Includind Allied Services For Officers, Jco’S & Or’S At Pune ( Army ) & Lonavla ( Navy )

Key Value

Document Fees
INR 3000 /-
EMD
INR 5875000.0 /-
Tender Value
INR 111 Crore /-

Attachment

FileName File Description File Size
8a63fcf8-ec4d-4dc5-bdab-effdb6c3f68d.html Tender Notice 0 KB
001100.pdf Tender Document 0 KB
101200.pdf Tender Document 0 KB
201300.pdf Tender Document 0 KB
301350.pdf Tender Document 0 KB
350400.pdf Tender Document 0 KB
401500.pdf Tender Document 0 KB
501600.pdf Tender Document 0 KB
601700.pdf Tender Document 0 KB
701800.pdf Tender Document 0 KB
801838.pdf Tender Document 0 KB
BOQ_728205.xls Tender Document 0 KB
GuardPost.pdf Tender Document 0 KB
punetender.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: COMPLETION OF BALANCE WORK FOR CONSTRUCTION OF DWELLING UNITS INCLUDIND ALLIED SERVICES FOR OFFICERS, JCO’s & OR’s AT PUNE (ARMY) & LONAVLA (NAVY)
Sl. No. Item Description
1Completion of balance work in Block of 32 (Thirty Two) dwelling units in Stilt + Eight (S + 8) contruction of RCC framed structure with covered garages in stilt and external covered garages along with servant quarters along with w/c, wash, seperate staircase of servant quarter, lift shaft / well, lift machine room, etc. with all fixtures, fitments, built in furniture complete as specified and shown in drawing at Station Workshop, Pune for Officers (Maj & above).
2(a) BLOCK- 1 (Pocket-I) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-1
3BLOCK- 5 (Pocket-I) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-5
4Completion of balance work in Block of 28 (Twenty Eight) dwelling units in Stilt + Seven (S + 7) contruction of RCC framed structure with covered garages in stilt and external covered garages along with servant quarters along with w/c, wash, seperate staircase of servant quarter, lift shaft / well, lift machine room, etc. with all fixtures, fitments, built in furniture complete as specified and shown in drawing at Station Workshop, Pune for Officers (Maj & above).
5BLOCK- 2 (Pocket-I) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-2
6BLOCK- 4 (Pocket-I) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-4
7Completion of balance work in Block of 20 (Twenty) dwelling units in Stilt + Five (S + 5) contruction of RCC framed structure with covered garages in stilt including servant quarters along with w/c, wash, seperate staircase of servant quarter, lift shaft / well, lift machine room, etc. with all fixtures, fitments, built in furniture complete as specified and shown in drawing at Station Workshop, Pune for Officers (Maj & above).
8BLOCK- 3 (Pocket-I) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-3
9Completion of balance work in Block of 4 (Four) dwelling units in Ground + One (G+1) of RCC framed structure including covered garages & servant quarters with w/c, wash, verandah, & seperate staircase of servent quarter with all fixtures, fitments, built in furniture complete as specified and shown in drawing for Officers complete at AFMC, 12 RF Lines, 8 PW Drive, Pune (Maj & above).
10BLOCK- 1 (8 P W DRIVE) (Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-6
11BLOCK- 2 (8 P W DRIVE) (Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-7
12BLOCK- 1 (12 RF Lines)(Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in hat yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-8
13BLOCK- 2 (12 RF Lines)(Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-9
14BLOCK- 2 (AFMC)(Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-11
15BLOCK- 3 (AFMC)(Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-12
16BLOCK- 4 (AFMC)(Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-13
17BLOCK- 5 (AFMC)(Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-14
18BLOCK- 6 (AFMC)(Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-15
19BLOCK- 7 (AFMC)(Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-16"
20Completion of balance work in Block of 2 (two) dwelling units in ground storey contruction of RCC framed structure including covered garages & servant quarters with w/c, wash, verandah with all fixtures, fitments, built in furniture complete as specified and shown in drawing for Officers complete at AFMC, 3 Alexander Road & AIPT, Pune officers (Maj &above).
21BLOCK- 1 (AFMC)(Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-10
22BLOCK- 1 (3 Alexander Road)(Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-21
23BLOCK- 2 (3 Alexander Road)(Pocket-III) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-22
24BLOCK- 1 (AIPT)(Pocket-III) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-23
25Construction of Blocks of 7 (Seven) dwelling units in ground + three (G + 3) storied construction of RCC framed structure including covered garages & w/c, wash, verandah with all fixtures, fitments, built in furniture complete as specified and shown in drawing at MH CTC Lullanagar, Pune for JCOs complete.
26BLOCK- 1 (Lullanagar)(Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-42
27BLOCK- 2 (Lullanagar)(Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-43
28Completion of balance work in Blocks of 6 (six) dwelling units in ground + two (G + 2) storied construction of RCC framed structure including covered garages & w/c, wash, verandah with all fixtures, fitments, built in furniture complete as specified and shown in drawing at AFMC & Kohima Lines, Pune for JCOs complete.
29BLOCK- 1 (AFMC)(Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-17
30BLOCK- 2 (AFMC)(Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-18"
31BLOCK- 3 (AFMC)(Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-19
32BLOCK- 4 (AFMC)(Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-20
33BLOCK- 1 (Kohima Lines)(Pocket-III) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-44
34BLOCK- 2 (Kohima Lines)(Pocket-III) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-45
35BLOCK- 3 (Kohima Lines)(Pocket-III) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-46
36Completion of balance work in Blocks of 4 (Four) dwelling units in ground + one storied (G+1) construction of RCC framed structure including covered garages & w/c, wash, verandah with all fixtures, fitments, built in furniture complete as specified and shown in drawing at AIPT, Pune for JCOs complete.
37BLOCK- 1 (AIPT)(Pocket-III) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-24
38Completion of balance work in Block of 20 (Twenty) dwelling unit in stilt + five (S + 5) storied construction of RCC framed structure including covered garages & w/c, wash, lift shaft / sell, lift machine room along with all fixtures, fitments, built in furniture complete as specified and shown in drawing at Ghorpadi for ORs complete.
39BLOCK- 1 (Ghorpadi)(Pocket-III) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-47
40BLOCK- 2 (Ghorpadi)(Pocket-III) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-48
41BLOCK- 3 (Ghorpadi)(Pocket-III) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-49
42BLOCK- 4 (Ghorpadi)(Pocket-III) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-50
43BLOCK- 5 (Ghorpadi)(Pocket-III) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-51
44BLOCK- 6 (Ghorpadi)(Pocket-III) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-52
45BLOCK- 7 (Ghorpadi)(Pocket-III) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-53
46BLOCK- 8 (Ghorpadi)(Pocket-III) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-54
47Completion of balance work in Block of 8 (Eight) dwelling unit in Ground + Three (G + 3) storied construction of RCC framed structure including covered garages & w/c, wash, verandah with all fixtures, fitments, built in furniture complete as specified and shown in drawing at MH CTC Lullanagar, Pune for ORs complete.
48BLOCK- 1 (Lullanagar) (Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-25
49BLOCK- 2 (Lullanagar) (Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-26
50BLOCK- 5 (Lullanagar) (Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-28 A
51BLOCK- 6 (Lullanagar) (Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-29
52BLOCK- 7 (Lullanagar) (Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-30
53BLOCK- 8 (Lullanagar) (Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-31
54BLOCK- 9 (Lullanagar) (Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-32
55BLOCK-10 (Lullanagar) (Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-33
56BLOCK-11 (Lullanagar) (Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-34
57BLOCK-12 (Lullanagar) (Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-35
58BLOCK-13 (Lullanagar) (Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-36
59BLOCK-14 (Lullanagar) (Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-37
60BLOCK-15 (Lullanagar) (Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-38
61BLOCK-16 (Lullanagar) (Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-39
62BLOCK-17 (Lullanagar) (Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-40
63BLOCK-18 (Lullanagar) (Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-41
64Completion of balance work in Block of 6 (Six) dwelling unit in Ground + Two (G + 2) storied construction of RCC framed structure including covered garages & w/c, wash, verandah with all fixtures, fitments, built in furniture complete as specified and shown in drawing at MH CTC Lullanagar for ORs complete.
65BLOCK-3 (Lullanagar) (Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-27
66BLOCK-4 (Lullanagar) (Pocket-II) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-28
67Construction of Garbage bin comprises of two seperate enclosures for dry and other for wet garbage including PCC block masonry construction, foundation, steel gate, saucer drain etc complete all as specified and shown on drawings for Pune pockets.
68Completion of balance work in Guard Post of RCC framed structure including w/c, washbasin, verandah with all fixtures, fitments etc. complete as specified and shown in drawings for station workshop , balance work in Pune Pockets. Annexure - LVI,
69Construction of Guard Post of RCC framed structure including w/c, wash, verandah with all fixtures, fitments etc. complete as specified and shown in drawings for Pune Pockets.
70Completion of balance work in Block of 4 (Four) dwelling units for Captains in Ground + One (G + 1) storied contruction of RCC framed structure including covered garages & servant quarters with w/c, wash, verandah, & seperate staircase of servant quarter with all fixtures, fitments, built in furniture complete as specified and shown in drawing etc. complete at LOV 01 (Duke"s Nose), Lonavla
71BLOCK-2 (Dukes Nose) (Pocket-I) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-55
72BLOCK-3 (Dukes Nose) (Pocket-I) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-56
73BLOCK-4 (Dukes Nose) (Pocket-I) Note : The details of work executed in percentage in terms of yardsticks, balance work in that yardsticks, reinforcement steel placed in position but not covered with concrete and photograph of block is enclosed as Appendix K-57
74Construction of Garbage bin comprises of two seperate enclosures for dry and other for wet garbage including PCC block masonry construction, foundation, PVC gate, saucer drain etc complete all as specified and shown on drawings for Lonavla Pockets
75Construction of Guard Post of RCC framed structure including w/c, wash, verandah with all fixtures, fitments etc. complete as specified and shown in drawing for Lonavla Pockets.
76Note: The balance work shown in annexures are for refrence purposes only. The contractor to visit the site and assess the exact quantum of balance work and quote their lump sum unit rate accordingly.
77SCH"A " SECTION - IIINTERNAL WATER SUPPLYTotal of Sch " A " Section -IIB/F from Serial Page No. 58
78. SCH"A " SECTION - III INTERNAL ELECTRIFICATIONTotal of Sch " A "Section -IIIB/F from Serial Page No.80
79SCH"A " SECTION- IVROAD,PATH AND CULVERT Total of Sch " A " Section -IVB/F from Serial Page No.89
80SCH"A " SECTION- VAREA DRAINAGETotal of Sch " A " Section -VB/F from Serial Page No. 93
81SCH"A " SECTION - VISECURITY WALL,FENCING & GATESTotal of Sch " A " Section -VIB/F from Serial Page No. 104
82SCH"A " SECTION - VIIRAIN WATER HARVESTING Total of Sch " A " Section -VIIB/F from Serial Page No. 108
83SCH"A " SECTION - VIII SOLAR HEATING SYSTEM Total of Sch " A " Section-VIIIB/F from Serial Page No. 118
84Sch "A" SECTION -IX STREET LIGHTING
85Earthing complete with galvanised steel earth plate electrode 600x600x6.3mm thick, burrieddirectlyinground(earthpitnotless than2.25Mdeepbelowgroundlevel)with topedgeoftheplatenotlessthan1.5M below normal ground level, connected to galvenised earthleadwire4.0mmdiaby means of bolts, nuts, check nuts and washers ofgalvenisedironorsteelallasshownin electricalplateno.3"SSRPart1of2009" connected to earthing test point all as specifiedorindicatedincludingtestingon completion.
86Earthing complete with galvanised steel earth plate electrode 600x600x6.3mm thick, burrieddirectlyinground(earthpitnotless than2.25Mdeepbelowgroundlevel)with topedgeoftheplatenotlessthan1.5M below normal ground level, connected to galvenisedstripof25x4mmearthleadby means of bolts, nuts, check nuts and washers ofgalvenisedironorsteelallasshownin electricalplateno.3"SSRPart1of2009", connected to earthing test point all as specifiedorindicatedincludingtestingon completion.
87Earthing complete with galvanised steel pipe electrode40mmbore,mediumgrade,2.5 meter lenght,burried directly in ground with top edge not less than 1.25 M below ground level, connected with GI earth wire 4 mm dia GIasearthingleadbymeansofbolts,nuts, check nuts and washers of galvanised iron or steelallasshowninelectricalplateNo.2 connected to earthing test point all as specifiedandindicatedincludingtestingon completion.
88Supplyandinstallationofearthcontinuity conductor or main earthing lead fixed to wall onbattenorrecessorchasesorburiedin ground or drawin in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4 mm dia. GI wire
89Supplyandinstallationofearthcontinuity conductor or main earthing lead fixed to wall onbattenorrecessorchasesorburiedin ground or drawin in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required 25 x 4 mmFlat GI Strip
90Supply, installation , testing & commissioningofSteeltubularswagedpole completewithbaseplate,finialtaperplug, bolts, nuts & screws as per specified type 410 SP-31(9meterlong)dulytwocoatedof synthetic enamelled paint over one coat of red oxideabovegroundlevelandblack bituminouspaintbelowgroundcompleteall as specified and directed
91Supply, installation, testing & commisioning of Post top lantern lamp pole (50 mm) shape, completewithbaseplate,finnialtaperplug, bolts,nuts & screws asper specified (2.5 meter long). Duly painted. In garden
92Supplyandfixingof50mmdia.GIPipe mediumgrade1.5mlongoneithersideof pole for cable protection.
93Supplyandinstallation ofReinforced concrete pipes,class NP2,laid and jointed complete with collars. 150 mm Dia
94Supply and Sand Filling in trenches for cable laying
95TypeD2-Cementconcreteinfoundations, filling and mass concrete 1:4:8 40mm graded aggregate
96TypeB1-Cementconcreteinfoundations, filling and mass concrete 1:2:4 20mm graded aggregate
97SupplyandinstallationundergroundXLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100V grade, cross sectional area .
984 core 25 sq.mm
994 core 16 sq.mm
1004 core 06 sq.mm
1013 core 06 sq.mm
1023 core 2.5 sq.mm
103SupplyandinstallationundergroundXLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100V grade, cross sectional area .
1044 core 25 sq.mm
1054 core 16 sq.mm
1064 core 06 sq.mm
1073 core 06 sq.mm
108SupplyandinstallationundergroundXLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100V grade, cross sectional area .
109Excavationandbackfilling,PCCpitand castironcover,funnelwithwateringpipe, wire mesh, lugs etc., for aboveGI Plate type earth Electrode.(soft disintegrated rocks)
110Supply,laying&terminatingof3core2.5 sq.mm,1100VgradePVCinsulatedcable from pole junctionboxto lampcontrolgear box
111Supply,laying&terminatingof3core1.5 sq.mm,1100VgradePVCinsulatedcable from pole junctionboxto lampcontrolgear box
112Supplyandlayingofun-reinforcedprecast concretecablecover,classLV,type1with peak, size 250mmx150mmx40mm
113Supply & fixing of Cable route markers made of galvanized iron with supporting G.I angle, for LT cable route marking
114Junction box fitted in the pole & comprising of6ASPMCBwith terminalssuitablefor terminating incoming and out going cables of 4core 16 sq.mm 1.1 kV grade armoured PVC insulated
115supply, erection of 50 mm, medium grade GI pipefixingstreetlightsinglebracketwith 1.5 M long.The rate should inclusive of supplyanderectionwithnecessaryclamp, screws, one coat of aluminium painting etc.
116supply, erection of 50 mm, medium grade GI pipefixingstreetlightdoublebracketwith 1.5 M long.The rate should inclusive of supplyanderectionwithnecessaryclamp, screws, one coat of aluminium painting etc.
117Design,supply,erectionof50mm,medium grade GI pipe fixing street light tripal bracketwith1.5Mlong.Therateshould inclusiveofsupplyanderectionwith necessaryclamp,screws,onecoatof aluminium painting etc..
118Supply and fixing of street light fitting sodium vapour lamp type 150W single piecediecast/deepdrawn,aluminium housing complete with control gear compartment, acrylic cover UV stablized, ballast of dual tapping, dynamic power savingdevicetoreducepowerto100Watt aftersixhoursofpeakload,prewiredwith lamp etc. Light fitting similar to Wipro make WST 76150 or equivalent
119Supply&fixingofsodiumvapourlamp type70WPosttoplanterntypecomplete with control gear , coveretc. similar to philips make SPC 101/70W , 70 Watt HPSV lamp or equivalent.
120Supply, installation, testing and commissioning of cubicle type, free standing, floormounted,StreetLightingDistribution Board working on 440V 3 phase, 50 Hz, AC, Supply.It shall be with aluminium bus bars, 2mmthickCRCAsheetsteelenclosure,pai nted as per the 7 tank process and painted for outdoor, weather proofIP-54 protection installation,asperspecificationandhaving the following details and the shown in single line diagrams.
121Incomer 1No.32A 3P,25 KA,MCCB &fixed neutral link N with S/C & adj. O/L releases, phaseindicationlamps,ammeter& voltmeterwith fuse.
1223Nos32AmpContactors(1Nofor100% lighting,1 No for 66% lighting, 1 No for 33% lighting)
1231 No timer electronic type with battery backup for controlling street light with adjustabletimerange(setting6P.Mto6 A.M)
124High Mast Supply& fixing ,Testing & commisioning of 30M high mast shaft in two sections suitable for 39 m/sec wind speed, with raising lowering system comprising, head frame, luminariescarriagesuitabletoinstall8nos supply of foundation bolts manufactured fromspecialsteelalongwithnuts,washers, anchorplatesandtemplates.Luminariesin sysmmetricalarrangement,doubledrum winch, 5 mm diameter SS wire rope, trailing cable,connector,integralpowertoolmotor, manualhandle,junctionbox,lightning finial.Foundation bolts with nuts and washers and anchor plates templets.Wiring of luminaireswithpvcinsulatedpvcsheathed flexiblecableofsuitablecopperconductor coresof2.5sqmm.Constructionofshallow foundation with M25 grade concrete for high mastconsidaringthesafesoilbearing capacityatsiteas10T/sqmtrsat2metre depth with all material and labour.
125S&FofGLSAviationLamp(twin)at terrace with fixing bracket, wiring and lamps etc.
126Supplyofnon-integralfloodlightluminaries typesimilartoWipromakeWST52400or equivalent,with Two no 400 W SV T lamp and its control gear box.
127Supply,Installation&TestingofOutdoor standmountedfeedermountedfeederpillar with32ATPMCB+Nincomer,singledial timeswitch,25ATPcontactorforthe automatic switching of lights, power tool controlwith2no9Acontactorsandraise lowerpushbutton,Incoming25sq.mmand outgoing 16 & 25 sq.mm terminals.
128Sch "A" SECTION- X LIFTS
129Supply, Installation, Testing and Commissioning of 13 Passenger (884 kg) Lift having contract speed of 1.5 Metres PerSecondservingdifferentfloorsintheliftshaftasper detailsgiven below:-
130Lifts shall conform to IS: 14665 with latest amendments
131Location of Lifts:Residential Dwelling Unit Blocksas shown in the architectural layout plans.
132Location of Lifts Machine room : Top (Above the lift shaft, common machine room as per the architectural layout plans foragroupof oneliftof13Personsandoneliftof8 persons)
133(i) Speed:1.5 MPS
134(ii) Floors:Stilt + 8 Floors.
135(iii)Travel: Basedon Stilt+8Floorsandarchitectural plans/sections.
136(iv) Stops and openings:On All Floors (Stilt + 8 Floors) on one side (I.e on the same side), entranceopening 2100 mm height x 900 mm wide
137(v)Controller:A.C VariableVoltage and Variable Frequency Controller
138(vi)AutomaticRescueDevicecompletewithdry maintenance free batteries as required.
139(vii) Operation: Microprocessor based duplex collective selective with/ without attendant.
140(viii) Power; 415V, 3 phase 4 wire system
141(ix) Type of doors:
142a)Cardoors;Poweroperated,centreopeninghorizontal sliding stainless steel scratch proof ( moon rock finish)
143Car doorsopening-
144b) Landing doors; Power operated, centre opening horizontal sliding M.S doors finished with spray painting of approoved shade.
145Landing Stops and openings-
146Stilt + 8 floors
147(x)Car size-
148Car inside 2000 mm wide and 1100 mm deep
149(xi) Emergency light and alarm bell-
150RechargableNi-Cdbatteryoperatedemergencylightand alarm bell.
151(xii)Ahandrailnotlessthan600mmlongand900mm above floor level to be fixed adjacent to control panel in the lift car.
152(xiii) Voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or stops at a floor served by the elevator.
153(xiv)InterfacingConnectionsforthebuildings P.Aand music system with necesaary flexible cables.
154(xv) Voltage stabiliser for the liftfor trouble free operation of the lift under supplyvoltage fluctuations.
155(xvi) Fireman"s switch
156Supply, Installation, Testing and Commissioning of 8 Passenger (544 kg) Lift having contract speed of 1.5 Metres PerSecondservingdifferentfloorsintheliftshaftasper detailsgiven below:-
157Lifts shall conform to IS: 14665 with latest amendments
158Location of Lifts:Residential Dwelling Unit Blocksas shown in the architectural layout plans.
159Location of Lifts Machine room : Top (Above the lift shaft, common machine room as per the architectural layout plans foragroupof oneliftof13Personsandoneliftof8 persons)
160(i) Speed:1.5 MPS
161(ii) Floors:Stilt + 8 Floors
162(iii)Travel: Basedon Stilt+8Floorsandarchitectural plans/sections.
163(iv) Stops and openings:On All Floors (Stilt + 8 Floors) on one side (I.e on the same side), entranceopening 2100 mm height x 800 mm wide.
164(v)Controller:A.C VariableVoltage and Variable Frequency Controller.
165(vi)AutomaticRescueDevicecompletewithdry maintenance free batteries as required.
166(vii) Operation: Microprocessor based duplex collective selective with/ without attendant.
167(viii) Power; 415V, 3 phase 4 wire system
168(ix) Type of doors:
169a)Cardoors;Poweroperated,centreopeninghorizontal sliding stainless steel scratch proof ( moon rock finish)
170Car doorsopening-
1712100 H x 800 W
172b) Landing doors; Power operated, centre opening horizontal sliding M.S doors finished with spray painting of approoved shade.
173Landing Stops and openings-
174G + 8 floors
175(x)Car size-
176Car inside 1300 mm wide and 1100 mm deep
177(xi) Emergency light and alarm bell-
178RechargableNi-Cdbatteryoperatedemergencylightand alarm bell.
179(xii)Ahandrailnotlessthan600mmlongand900mm above floor level to be fixed adjacent to control panel in the lift car.
180(xii) Voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or stops at a floor served by the elevator.
181(xiv)InterfacingConnectionsforthebuildings P.Aand music system with necesaary flexible cables.
182(xv) Voltage stabiliser for the liftfor trouble free operation of the lift under supplyvoltage fluctuations.
183(xvi) Fireman"s switch
184Supply, Installation, Testing and Commissioning of 13 Passenger (884 kg) Lift having contract speed of 1.5 Metres PerSecondservingdifferentfloorsintheliftshaftasper detailsgiven below:-
185Lifts shall conform to IS: 14665 with latest amendments
186Location of Lifts:Residential Dwelling Unit Blocksas shown in the architectural layout plans.
187Location of Lifts Machine room : Top (Above the lift shaft, common machine room as per the architectural layout plans foragroupof oneliftof13Personsandoneliftof8 persons)
188(i) Speed:1.5 MPS
189(ii) Floors:Stilt + 7 Floors
190(iii)Travel: Basedon Stilt+7Floorsandarchitectural plans/sections.
191(iv) Stops and openings:On All Floors (Stilt + 7 Floors) on one side (I.e on the same side), entranceopening 2100 mm height x 900 mm wide
192(v)Controller:A.C VariableVoltage and Variable Frequency Controller
193(vi)AutomaticRescueDevicecompletewithdry maintenance free batteries as required.
194(vii) Operation: Microprocessor based duplex collective selective with/ without attendant.
195(viii) Power; 415V, 3 phase 4 wire system
196(ix) Type of doors:
197a)Cardoors;Poweroperated,centreopeninghorizontal sliding stainless steel scratch proof ( moon rock finish)
198Car doorsopening-
1992100 H x 900 W
200b) Landing doors; Power operated, centre opening horizontal sliding M.S doors finished with spray painting of approoved shade.
201Landing Stops and openings-
202G + 7 floors
203(x)Car size-
204Car inside 2000 mm wide and 1100 mm deep
205(xi) Emergency light and alarm bell-
206RechargableNi-Cdbatteryoperatedemergencylightand alarm bell.
207(xii)Ahandrailnotlessthan600mmlongand900mm above floor level to be fixed adjacent to control panel in the lift car.
208(xiii) Voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or stops at a floor served by the elevator.
209(xiv)InterfacingConnectionsforthebuildings P.Aand music system with necesaary flexible cables.
210(xv) Voltage stabiliser for the liftfor trouble free operation of the lift under supplyvoltage fluctuations.
211(xvi) Fireman"s switch
212Supply,Installation,TestingandCommissioningof8 Passenger (544 kg) Lift having contract speed of 1.5 MetresPerSecondservingdifferentfloorsinthelift shaft as per detailsgiven below:-
213LiftsshallconformtoIS:14665withlatest amendments
214LocationofLifts:ResidentialDwellingUnitBlocks as shown in the architectural layout plans.
215LocationofLiftsMachineroom:Top(Abovethelift shaft, common machine room as per the architectural layout plans for a group ofone lift of 13 Persons and one lift of 8 persons)
216(i) Speed:1.5 MPS
217(ii) Floors:Stilt + 7 Floors
218(iii) Travel:Based onStilt + 7 Floors and architectural plans/sections.
219(iv)Stopsandopenings: OnAllFloors(Stilt+7 Floors)ononeside(I.eonthesameside), entrance opening 2100 mm height x 800 mm wide
220(v)Controller:A.C Variable Voltage and Variable Frequency Controller
221(vi) Automatic Rescue Device complete with dry maintenance free batteries as required.
222(vii) Operation: Microprocessor based duplex collective selective with/ without attendant.
223(viii) Power; 415V, 3 phase 4 wire system
224(ix) Type of doors:
225a) Car doors; Power operated, centre opening horizontal sliding stainless steel scratch proof ( moon rock finish)
226Car doorsopening-
2272100 H x 800 W
228b) Landingdoors;Power operated,centreopening horizontal sliding M.S doors finished with spray painting of approoved shade.
229Landing Stops and openings-
230Stilt + 7 floors
231(x)Car size-
232Car inside 1300 mm wide and 1100 mm deep
233(xi) Emergency light and alarm bell-
234RechargableNi-Cdbatteryoperatedemergencylight and alarm bell.
235(xii)Ahandrailnotlessthan600mmlongand900 mmabovefloorleveltobefixedadjacenttocontrol panel in the lift car.
236(xii) Voice announcement system in the car to announce the position of the elevator in the hoistway asthecarpassesorstopsatafloorservedbythe elevator.
237(xiv) Interfacing Connections for the buildingsP.A and music system with necesaary flexible cables.
238(xv) Voltage stabiliser for the lift for trouble free operation of the lift under supplyvoltage fluctuations.
239(xvi) Fireman"s switch
240Supply, Installation, Testing and Commissioning of 13 Passenger (884 kg) Lift having contract speed of 1.0 MetresPerSecondservingdifferentfloorsinthelift shaft as per detailsgiven below:-
241LiftsshallconformtoIS:14665withlatest amendments
242LocationofLifts:ResidentialDwellingUnitBlocks as shown in the architectural layout plans.
243LocationofLiftsMachineroom:Top(Abovethelift shaft, common machine room as per the architectural layout plans for a group ofone lift of 13 Persons and one lift of 8 persons)
244(i) Speed:1.0 MPS
245(ii) Floors:Stilt + 5 Floors
246(iii) Travel:Based onStilt + 5 Floors and architectural plans/sections.
247(iv)Stopsandopenings: OnAllFloors(Stilt+5 Floors)ononeside(I.eonthesameside), entrance
248(v)Controller:A.C Variable Voltage and Variable Frequency Controller
249(vi) Automatic Rescue Device complete with dry maintenance free batteries as required.
250(vii) Operation: Microprocessor based duplex collective selective with/ without attendant.
251(viii) Power; 415V, 3 phase 4 wire system
252(ix) Type of doors:
253a) Car doors; Power operated, centre opening horizontal sliding stainless steel scratch proof ( moon rock finish)
254Car doorsopening-
2552100 H x 900 W
256b) Landingdoors;Power operated,centreopening horizontal sliding M.S doors finished with spray painting of approoved shade.
257Landing Stops and openings-
258Stilt + 5 floors
259(x)Car size-
260Car inside 2000 mm wide and 1100 mm deep
261(xi) Emergency light and alarm bell-
262RechargableNi-Cdbatteryoperatedemergencylight and alarm bell.
263(xii)Ahandrailnotlessthan600mmlongand900 mmabovefloorleveltobefixedadjacenttocontrol panel in the lift car.
264(xiii) Voice announcement system in the car to announce the position of the elevator in the hoistway asthecarpassesorstopsatafloorservedbythe elevator.
265(xiv) Interfacing Connections for the buildingsP.A and music system with necesaary flexible cables.
266(xv) Voltage stabiliser for the lift for trouble free operation of the lift under supplyvoltage fluctuations.
267(xvi) Fireman"s switch
268Sch "A" SECTION- XI FIRE FIGHTING
269Providing fixing, welding, testing and commissioning of MSpipe(heavy)confirmingtoIS:1239withrequired accessories and pipe fittings like flange, tee, elbow, bend nipple, coupling, cap, reducer, union, flange joint, CAF insertion,nutbolteycandRediographylimitedto10 includingfixingthepipewithsuitableG.I.flatstrip clamp/U-clamp/brckets/ hangerandpainting withone coat primer and two or more coats of postal red enamel paintofapprovedbrand,hydrostatictesting etc,asper specifications and instructions of site in charge.
270Ø150 mm
271Ø100 mm
272Ø80 mm
273Ø50 mm
274Provding, fixing andcommissioning of ISI marked cast irondoubleflangedSluicevalvecompletewith companion flanges, pipe fittings, bolts, nuts CAF gasket etc duly painted as per specification.
275Ø100 mm
276Ø50 mm
277Hydrant valves Providing and fixing bolting, welding, Radiography testing painting and commissioning of hydrant valves single headed ISI marked 63 mm dia single headed landing valve CI hand wheel CAF gasket, nuts, bolts, etc conforming to IS: 5290-1977 type A for external and internal hydrants as per pecifications and instructions of site incharge.
278Providing and fixingBranch pipe & nozzle. ISI marked 63 mm dia male instantaneous inlet spray nozzle made of gun metal to IS: 903arrangementfor straightstream spray,shut-off and trigger type handle as per sepcifications.
279Providingandfixingfirefightingdeliveryhose,PRL Hosepipe15mlong63mmdiaISImarked,non- percolating,flexible,3layeredsyntheticjacketedwith electrometricoutercovering,resistanttoliquids, chemicals, acids, alkalis, solvents, abrasion & heat having 42 Kg /cm2 burst pressure, 18 Kg /cm2 working pressure, conforming to IS: 636-1988 type-B and having TAC MMDapprovals in 15 mtr length with copper wire bounded.Instantaneoustype63mmfirehosepairof male & female coupling made of aluminium alloy (anodised) / gun metal in each run of hose conforming to IS: 903 as per tender requriements / specifications.
280Providing andfixing ISImarkedfirstaidfirehose reel conforming to IS: 884-1985 comprise of reel hose guide, fullswingdrumfixingbracket,20mm bore36meters longhigh-pressure braidedrubberhosetubing conform toIS:1532-1969,25mm diaballvalve,stainlesssteel stop cock and nozzle duly painted as per tender requirements/specificationsandinstructionsofsite incharge.
281M. S. Box / Cabinets internal hose Cabinet of single shutter glaged door ,made ofrectugularmetallicesheetsectionof(1500x900x 450)mm size.
282Supplying,painting, installing, testing & commissioning of Air Cushion Tanks.As per spec.
283Providing and fixing Air vessel on top of wet riser with 450 mm dia, 1.5m high, fabricated with min 8 mm thick mild steel sheet ,vent drain ball valve (1"NB) ( auto air release valve ) with necessory accessories
284Fire Brigade Connection Four way fire brigade inlet with 150 NB with Butterfly valve and NRV with matching flanges.
285Providing, supplying, installing, testingand commissioning of horizontally mounted centrifugal type pumprunning at 2900/3000rpm capabl e of delivering 900 LPM at45 MWC,10 HPcomplete withtail piece forproperconnectiontosuctionanddeliverylineand bypassarrangementfortestingwithbronzeimpellers completewithmechanicalsealmotorTECF2900rpm 415 V (+/-) 3% class FIP 55
286Providing, supplying, installing, testing and commissioning of control panel for terrace pump , DOL with necessary MCCB contractor overload relay digital volt meter, ammeter auto / manual selector switch indicating lamp, etc. suitable for 10 HP terrace pump
287Pressure Gauge: Supplying and installing pressure gauge complete in all respect with syphon and plug valves
288Non Return Valves: Supplying and installing C.I. double flangedNRVwithmatchingflangesoffollowingsizes complete in all respect
289Ø150 mm
290Ø100 mm
291Booster Pump Panel(Terrace Level): Supply, installation, testing and commissioning of wall mounted cubicle type panel with specification same as main panel forconstructionasabove.A/Mselectorandinterlock with pressure switch.
292Supply, installation, testing and commissioning of cables laidontraysorwall.Completeinallrespectasper specifications.Supply, installation, testing and commissioning of cables laidontraysorwall.Completeinallrespectasper specifications. 4C x 6 sq.mmXLPE insulated armoured ‘CU’ Cable ( IS -7098-Part-I)
2934C x 2.5 sq.mmXLPE insulated armoured ‘CU’ Cable
294Making cable termination of cables by using brass gland connectingto theterminals by usingcrimpingtype copper lugs, etc. complete as required. 4C x 6 sq.mm ‘CU’ Termination
2954C x 2.5 sq.mm ‘CU’ Termination
296Earthing
297Supply, fixing of Copper Strip, laying, testing and commissioning of earthling flats using GI spacers and GI clamps for G 1 plate earthing (20 x 3 mmcopper strip)
298SupplyingandfixingvarioustypeofMSmateriallike angle, channel flat required for makingtray asper requirement,whichincludescutting,welding,painting with two coats of zinc rich epoxy and one coat of epoxy paint for150 mm wide GI perforated cable tray.
299Supply&fabricationofmildsteelsupports,Ubolts, clamps, nuts & bolts, anchore fasteners for pipe support withpainting (MS angle iron support of size 40X40X5 mmwith"U"Bolts&anchorfasterdulypaintingwith two coats of zinc rich epoxy & one coat of epoxy paint in Fire Red shade.)
300Y" Type Strainer: Supplying, installing & testing of cast iron "Y" type strainer with GI / Chromium plated matching flanges with GI nuts, bolts, washers etc. CompleteasrequiredasperPN16,testedupto24 kg/cm2 pressure.
301Ø150 mm
302Ø100 mm
303PORTABLE FIRE EXTINGUISHERS
304CO2 extinguisher 4.5 Kgs. capacity - IS 2878 complete with initial charge & supporting
305AFFFextinguisher mechanicalfoamtype9.0Liters capacity - IS 940 complete with initial charge & supporting
306DCPpowdertype(ABC)5Kgs.-IS2171complete with initial charge & brackets
307FIRE ALARM SYSTEM
308Supply,installation,testing andcommissioning of microprocessor based UN/EN 54 compliant analog addressable intelligent fire Firealarmcontrol single panel loop complete with central processing unit. Network communication card RS -485 port , 80 CharactersLCDdisplaywithprimarypowersupplyat 230Vwith24/36volts.sealmaintenancefree(SMF) batteriesbackup(asperIS)complete withsoildstate boot/trickleautomaticbatterycharger.Thepanelshall supportGraphicspackageforcentralmonitoringofall devices.
309Supply,installation,testingandcommissioningofhard addressable type manual call point, 1 stage with in built LED,lighting upautomaticallyto confirm its actuation complete as per specification as required.
310Supply,installtion,testingandcommissoningofUL/EN listed wall mounted hooter with strobe (100 bda) complete as per specification as required.
311Supply,installation,testing andcommissioning of addressable input/out control module for shutting down AHU"s,liftpressurizationfansandventilationfansetc. includingpowersupplyfordirvingthecontrolmodule as per requirement.
312Supply,laying,testing and commissioning of point wiring for sensors and devices with 2 x 1.5 Sq.mm. FRLS PVC insulatedmulti-strandedsinglecorecopperconductor wire in M.S. conduit with conduit accessories including loop circuit from main fire alarm panel located at ground floor in fire control room complete as required.
313SCH"A " SECTION - IIINTERNAL WATER SUPPLYTotal of Sch " A " Section -IIB/F from Serial Page No. 58
314SCH"A " SECTION - III INTERNAL ELECTRIFICATIONTotal of Sch " A "Section -IIIB/F from Serial Page No.80
315SCH "A" SECTION - XIV STRENGTHENING MEASURES BASED ON STRUCTURAL AUDIT REPORT
316Providing and fixing double scaffolding system(cuplocktype)on the exterior side of building/ structure, including additional rows of scaffoldingin stepped manner as per requirement of site, made with 40mm dia M.S.tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S.tube challis, M.S.clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/or pointing and/or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connectingwith the building etc, wherever required,if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:-(1)The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works.
317Providing and fixing Jute Kantan(Tarat) screen to thes scaffold-ing for external guniting as directed including removing the same after the work is over etc. complete.
318Dismantling brick masonry in lime or cement mortar and stacking the materils asdirected with all leads, lifts etc.
319ChippingofalllooseandSpallingofconcretetobottomofslab,beamsetc.(wherever required), cleaning of reinforcement, carrying out thorough sand blasting, application of anti- corrosive zinc rich epoxy primer to exposed reinforcement including cost of material, labour, equipment, tools, scaffolding etc. complete.
320Lowering down the debris obtainedfrom breaking and removing the cement plaster / burnt brick masonry of the first floor by any means without causing dust nuisance and damage to structure, stacking the same as and where directed including cleaning the site complete.
321Providing & ApplyingDuraClean- WR- for cleaning the TMT bars, steel structure etc. of structure by Waterjet cleaning/ grinding the surface by grinder machine, wire brush, removing existing corrosion from the metal surface also removing loose particles(using other mechanical/manualmeans)andapplyonpreparedsurfaceofDuraCap2coatscorrosion preventivecoatonpreparedTMTbars,steelstructure,metalsurfaceetc.toprotectitfrom corrosionetc. as per manufacturer"s specification( using other manual/ mechinicalmeans) completeasperspecificationincludingcostofallmaterials,machinery,labour,insurance chargesas directed by the Engineer in charge.
322Carry out application of "Bi-polar migratory corrosion inhibitor" on concrete surface. This inhibitor has migratory kind of property which permits the material to migrate to a virtual extent of 100mm, through pores of concrete,inhibiting the corrosion etc complete.
323Cathodic Protection/Prevention using Dual Phase Hybrid Fusion anodes system: Providing and fixing self-powered dual phase Hybrid anode Galva shield Fusion T2-135 Type 2 Class C sacrificial zinc anode of Vector/ SRMPL/ Life Anode 65 Krishna Conchem Corrosion Technologies or equivalent make as approved by Engineer-in-Charge to protect and prevent initialization of corrosion of reinforcement in RCC Elements by installing anodes for entire surface of RCC element as per design based on corrosion rates as prescribed in contract document (spacing shall be 400 to 750mm as prescribed in tender document), as per manufacturer specification,covered with mortar with of resistivity less than of parent concrete including making connections with reinforcement steel as per manufacturers specification before applying cementatious overlay system at all heights and including of all design, rebar location, making chases, grooves for wire, checking connectivity with approved multimeter, drilling for rebar connection, establishing connection with rebar with special rebar connector, installing anodes with proper connection using buttom type connector and covering with mortar, material,labour, tools, plant and machineries, etc.complete as directed by Engineer-in-charge.
324Providing, drilling and fixing Nipples/ Nozzles for pressure injection grouting of polymer cement grout / epoxy groutetc. Complete
325Providing Grounting of nozzles with Low Viscosity Epoxy grout including material, labour complete in all respect.
326Providing and applying epoxy bonding agent for bonding old to new concrete for structural members prior applying the epoxy mortar to the concrete surfaces etc complete.
327Providing Repairing of honey combs and minor damages with Polymer Modified Morter includingmaterial, labour complete in all respect.
328Re-casting of bracket with micro-concrete and 10 mm agrregate ( 1:1) with leakproof shuttering all manpower and equipments complete in all respect
329Provisional sum for shifting of Electrical lines from Maharashtra State Electricity Distribution Co. Ltd both for Stn HQ and Lullanagar.
330SCH"A " SECTION - XV DEMOLITION /DISMANTLING & CREDIT Total of Sch " A " Section -XV B/F from Serial Page No138
331SCH"A " SECTION - XVI SCH "A" SECTION- XVI SCHEDULE OF CREDIT Total of Sch " A " Section -XVI B/F from Serial Page No. 146
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail