}

Tender For Provision Of 1.5 Mva Ht Automatic Voltage Regulator With Connected Works At 33/11 Kv Mrs Of Jak Li Rc Under Ge 970 Ews, Srinagar-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Provision Of 1.5 Mva Ht Automatic Voltage Regulator With Connected Works At 33/11 Kv Mrs Of Jak Li Rc Under Ge 970 Ews. Submission Date for this Tender is 14-05-2024. Electrical Products Tenders in Srinagar Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

43226764
Tender For Provision Of 1.5 Mva Ht Automatic Voltage Regulator With Connected Works At 33/11 Kv Mrs Of Jak Li Rc Under Ge 970 Ews
Open Tender
Indian
Jammu And Kashmir
Srinagar
14-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Provision Of 1.5 Mva Ht Automatic Voltage Regulator With Connected Works At 33 / 11 Kv Mrs Of Jak Li Rc Under Ge 970 Ews

Key Value

Document Fees
INR 500 /-
EMD
INR 85740.0 /-
Tender Value
INR 42.87 Lakhs /-

Attachment

FileName File Description File Size
42a6f094-ff78-4695-b93a-1628b271621d.html Tender Notice 0 KB
BOQ_728633.xls Tender Document 0 KB
tender.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work : PROVN OF 1.5 MVA HT AUTOMATIC VOLTAGE REGULATOR WITH CONNECTED WORKS AT 33/11 KV MRS OF JAK LI RC UNDER GE 970 EWS.
Sl. No. Item Description
1Supply, installation, testing and commissioning of copper wound HT, AVR suitable for outdoor installation of capacity 1500 KVA, suitable outdoor HV input voltage range of 7 KV to 12 KV, HV output voltage 11 KV (+/-) 1% with the following all standard fittings, such as silica gel breather, temperature gauge, bucholz relay, WTI & OTI trip & alarm including by pass connections with all control cables of appropriate rating technical specifications of HT AVR, complete with the fooolowings :- (A) RATINGS :- Rating in KVA : 1500 KVA,Number of phases & Frequency : 3 Ph 50 Hz. Type of cooling : ONAN, Rated Voltage : 11 KV, Input Voltage Range : 7 KV to 12 KV, Input Current Range : 123.72 A to 72.17 A, Output Voltage : 11 KV +1% Output Current : 78.73A, Correction Rate : KV/ Second : 50V/Sec,Operating frequency : 50 HZ, Duty Cycle : 100% Continuous Load, Type of Load : More than 99%, Guaranteed Over-all efficiency : 98.65%, Winding : Electrolytic grade copper purity 99.08% IMPEDANCE : 1.95%,
2(B) EFFICIENCY :- At Full Load & 1.0 P.F & 75 deg C : 98.18%, 3/4 : 98.47 %, 1/2 : 98.66%, 1/4 : 98.48%. (C) TEMPERATURE RISE :- Ref. Ambient Degree C : 45, Oil by thermometer Degree C : 45, Winding by Resistance Degree C : 55, (D) INSULATION WITHSTAND :- Impulse (1.2x50 micro second wave) : 125KV, Power Frequency (Dry & Wet) : 50KV for 1 Minute. (E) SYSTEM NEUTRAL :- Effectively Earthed / Resonant Non effectively Earthed / Isolated : Isolated AVR. (F) CONTROL :- Input/ output Selector Switch, Auto Manual Selector Switch, Increase /Decrease switch to control the output voltage in Manual Mode Voltage Adjust to set required output, voltage in AUTO Mode, Single Phase Preventor. (G) INDICATIONS :- Input On, Input Low, Input High, Output Cut Off (H) CORE LAMINATIONS :- Type : CRGO, Material : Silicon, Steel Lamination, Thickness : 0.3 (J) Terminal Bushing Minimum Clearance in Air :- 11 KV Phase to Phase : 200mm 11 KV,Phase to Ground : 385mm,Minimum Creepage Distance : 385mm (K) ACCESSORES :- 150mm Dai Dial type thermometer with Alarm and trip contacts 150mm Dai Dial type thermometer with Alarm and trip contacts Buchholz Relay (Double float) 150mm Dia Winding Temperature indicator 4 Nos Wheels Plain / Flanged /Bi-directional / Uni-directional Explosion Vent diaphragm Silicagel breather Valves.
3(L) TERMINATION ARRANGEMENT :- H.V. SIDE (CABLE BOX): Auxiliary L.V. (Cable box), Disconnecting Chambers for HT, Conservator with oil filling hole with cap & drain plug with extension of pipe. (M) Detachable radiator with shut off valve. (N) Oil level gauge with 3 position, Filter valve 25mmsize, Air release valve, Rating & terminal marking plate. (O) Weather proof Marshaling box with connection for above auxiliary protection with Lamp holder with Switch. (P) Miscellaneous :- Test Required : Routine Test, All routine test as per IS : 2026, Oil Pressure & Vacuum with stand test : 7 PSI, Colour shade : D.A.Gary (Q) GENERAL ARRANGEMENT :- The unit consists of following :- (i) Stepdown Transformer- Double wound Delta/Star connected. (ii) ‘ON’ Load Voltage Regulator, Auto wound Delta connected. (iii) Buck-Boost Transformer, Double wound, open/open connected. (iv) Automatic control gear consisting of :- One Electronic Voltage Relay, One Reversing Stepsyn type geared motor unit, Two limit switches in order to avoid overrunning highest and lowest positions, chain drive, coupling device and all electrical connection.
4(R) CONSTRUCTION :- The items (A) & (C) will be housed inside a well ventilated sheet steel tank and mounted on feet and items shall be supplied with first filing of oil, fittings would include :- (i) Rating & Diagram Plate (ii) Silica gel breather (iii) Earthing Terminals (iv) Lifting lugs (v) Drain valve (vi) Air Release plug (vii) Oil Conservator with Oil level indicator (viii) Filter valve (ix) Pressure Relief Valve (x) W.T.I. & O.T.I (xi) Buchholz Relay (S) GENERAL FEATURES :- (i) HAND CONTROL :- Hand wheel will be located on the front of the Regulator tank at convenient operative height. (ii) MOTOR CONTROL :- Raise / Lower push button control by means of small single phase reversible geared motor of permanent capacitor type will be provided. Limit switches will be fitted to restrict the travel at extreme positions. With this arrangement, it would also be possible to provide remote control to the Regulating Unit. The reversible geared motor would be of ‘Step-Syn’ type. (iii) AUTOMATIC CONTROL :- For automatic correction of fluctuating supply voltage, we shall provide Electronic Relay which in its simplest form, senses the Output Voltage and provide signal to the driving motor for necessary correction. Note :- The contractor shall get approval of design & drawings of equipment(s) from Accepting Officer before procurement of equipment(s).
5Supply, installation, commissioning and testing ofVCB panel SF6 with complete copper busbar arrangements &SITC of new OEM 11 KV VCB Panel Board consisting of 1 incoming/ outgoing indoor type, 800 Amps, 25 KA for 3 Sec, The panel shall be fully tested. The incoming feeder compartments shall have drawn out type PT and the VCB compartments shall have metering and protection CTs as required. The switchgear shall be designed for a symmetrical breaking capacity of not less than 25KA confirming to IS / IEC : 62271-100, 62271-102 with latest amendments including breaker including the cost of all required accessories, handling, transportation, CTs, draw out type PTs with rolling floor design for ease of maintenance & numerical relays for over current, earth fault, current & voltage displays, alarm and annunciation, indications, meters, LT control & instrumentation cables of required specifications etc. complete in all respect for proper completion of work. Vacuum Circuit Breakers must be manufactured by ISO:9000 certified manufacturer and shall have been type tested at CPRI/ NABL accredited laboratory or any Govt. approval laboratory within 10 years as on the date of bid (Technical) opening and in satisfactory operation for a period not less than three years. The copies of type test reports shall be provided at the time of supply to AGE (I) / Engineer-in-Charge, complete all as specified, directed and manufacturer"s instructions.
6The VCB must have the following :- (a) 800 Amps bus bar, the material shall be of high conductivity electrolytic copper only. All bus bars shall be heat-shrinkable PVC sleeves and joints shall be covered by HT sleeve as per 15 including color coding for phase indication - 01 Job. (b) Circuit breaker shall be mounted on a withdrawal truck which shall roll out horizontal from service position to isolated position with and including suitable size (as per manufacturer"s recommendation) AC Powerpack and suitable to operate entire control system and having sufficient power back up to operate TRIP / CLOSING operation at least 5 times including inbuilt charging system 24 volts DC - 01 Job. (c) Motorised spring charging mechanism 230 volts AC - 01 Job. (d) Cast resin current transformer suitable to 11 KV, indoor VCB, 11KV, 100-50A/5+5A, burden, accuracy class 5P10 for protection and class-1.0 for a metering - 01 Job.
7Space Heaters :- (a) The panels shall be provided with space heaters to prevent moisture condensation, and maintain cubicle temperature 5°C above the ambient. (b) The space heaters shall be located at the bottom of the panel and shall be controlled through a double pole MCB and a thermostat with an adjustable setting range of 30 to 70°C. Space heaters shall be supplied from 240 V AC auxiliary bus for a space heater. (c) The work also include the interconnection of existing VCB Panel with complete bus bar connection arrangement and enclousure with above mentioned VCB Panel. The cost of the same must be included in the rates qouted by the contractor. (d) Any other item required to complete the job, is deemed to be included in the rate quoted by the contractor complete all as specified and directed. Note :- The contractor shall get approval of design & drawings of equipment(s) from Accepting Officer before procurement of equipment(s).
8Supply, laying, commissioning & testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 11000 volts grade, cross sectional area 185 Sqmm 3 Core, laid in trenches/ floor/ duct/ fixed on poles/ through GI tubing, complete all as specified and directed. Note :- (a) Excavation, earth work, sand cushioning and PCC cable covers will be measured and paid separately under respective items of this BOQ. (b) Cable shall be tested after laying/ fixing and rates for the shall be deemed to include in the quoted rates.
9M&L for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm, complete all as specified and directed.
10M&L for earthing complete with copper earth plate electrode of size 600x600x3.15mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below from normal ground level), connecting to the copper earth strip of size 20x3mm by means of bolts, nuts, check nuts and washers of galvanised iron and earth lead protected by 40mm bore GI pipe, light grade including provision of conrete pit PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) with 40mm thick cover of RCC (1:2:4) type B-1, reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x3mm and with 6mm dia MS bar handle, made to shape, 20mm bore GI light grade pipe for watering pipe, placed on top edge of earth plate and including common salt and charcoal filling, test point with fixing arrangements, funnel, wire mesh and earth work in any type of soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 mtr, complete as per electrical plate No. 3 of MES SSR Part-I (2009), complete all as specified and directed. Note :- The earthing will be tested after completion, if desire results not achieved, the contractor redo the earthing and rates for the same shall be deemed to include in the quoted rates.
11M&L for construction of Platform/ foundation for 1500 KVA AVR, size 3.0 mtr in width x 5.0 mtr in length x 1.0 mtr high above ground level, PCC 1:4:8, type D-2 (using 40mm graded stone aggregates) as in foundation, brick work with sub class "B" bricks build in cement mortar 1:6, 15mm thick rendering in cement mortar 1:4 with and including 100mm below ground level, two coats of cement base paint over a coat of alkali resistant primer, PCC 1:2:4, type B-1 (using 20mm graded stone aggregates) as in coping etc. including necessary formwork and including excavation, earth work, removal, re-filling etc, complete all as specified and directed. Note :- PCC type D-2, PCC type B-1, brickwork and rendering shallbe measured and paid separately under respective items of this BOQ only.
12M&L for plain cement concrete 1:4:8, type D-2 (using 40mm graded crushed stone aggragates) as in foundation, filling in etc., complete all as specified and directed.
13M&L for cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in copings, kneelers, bed plates, kerbs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
14M&L for brick work with sub class "B" bricks, old size, straight or curved on plan exceeding 6 Mtr mean radius, built in cement mortar 1:6, complete all as specified and directed.
15M&L for 15mm thick rendering in cement mortar 1:4 on fair faces of brick wall or concrete surfaces, finished the surface even and fair without using extra cement, complete all as specified and directed.
16Excavation in trenches, not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying/ taking out of XLPE cables, foundation of pole, ducts etc. and getting out in soft/ loose soil, complete all as specified and directed.
17Returning, filling in trenches including spreading, leveling and well ramming in layers not exc 25cm thick, complete all as specified and directed.
18Removing excavated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and directed.
19M&L for dry river sand, laid in trenches for cable protection, as 15cm thick below the cable and 8cm thick above the cable, complete all as specified and directed. Note :- Punned thickness of sand shall be measured and paid.
20Supplying and laying reinforced precast concrete cable cover, Class HV, Type 1, flat, size 300mmx 180mm x 40mm, as per IS-5820-1970, ISI Marked, complete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail