Tender For Petty Repairs To Internal Electric System At New Mh And Connected Single Accommodation Of Mh Bareilly Cantt Under Ge (West) Bareilly, bareilly-Uttar Pradesh

Military Engineer Services-MES has published Tender For Petty Repairs To Internal Electric System At New Mh And Connected Single Accommodation Of Mh Bareilly Cantt Under Ge (West) Bareilly. Submission Date for this Tender is 13-05-2024. Electrical Products Tenders in bareilly Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43226451
Tender For Petty Repairs To Internal Electric System At New Mh And Connected Single Accommodation Of Mh Bareilly Cantt Under Ge (West) Bareilly
Open Tender
Indian
Uttar Pradesh
bareilly
13-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Petty Repairs To Internal Electric System At New Mh And Connected Single Accommodation Of Mh Bareilly Cantt Under Ge (West) Bareilly

Key Value

Document Fees
INR 500 /-
EMD
INR 64000.0 /-
Tender Value
INR 32 Lakhs /-

Attachment

FileName File Description File Size
937be65d-d9dd-4bc3-b55e-201dc4834672.html Tender Notice 0 KB
BOQ_728624.xls Tender Document 0 KB
copmpletetender8175.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

NAME OF WORK: PETTY REPAIRS TO INTERNAL ELECTRIC SYSTEM AT NEW MH AND CONNECTED SINGLE ACCN OF MH BAREILLY CANTT UNDER GE (WEST) BAREILLY.
Sl. No. Item Description
1Taking down carefully existing Aluminum/Copper point wiring (light/ Fan / Socket/Power Point) complete fittings etc. making good to disturbed surface of wall/Floor etc to match the existing surface/ finishes complete all as specified and directed.
2M&L for concealedpoint wiring with1.5 Sqmm (Nominal area)PVCinsulated,unsheathed, multi stranded Copper conductor cable drawn in and including PVC rigid PVC conduit 25mm or higher sizewith all its fittngs and accessories for one 3 pin/6 pin 15 Amps socket out let point independent alongwith PVC insulated cable with multistranded copper conductor 1.5 Sqmm (nominal area) continuous earth wire, and connected to earth dolly including fixing of 1.20 mm sunk pressed steel terminal box/ MS modular box suitably flushedto wall with 3mm thick Hylum sheet cover/ white colour modular plate with coverfor housing switch, socket regulator etcfixed with screws & cup washers incl. making good complete all as specified and directed.
3(a)All as per item no.2 here in before but for One light/fan point controlled by one switch 5/6 Amp one waycomplete all as specified and directed.
4(b) All as per item no.2 here in before but for socket outlet 3/5 pin 5 amp. on the same board complete all as specified and directed.
5(c ) All as per item No 02 here-in-before but for 5 Amps 3/5 Pinpoint on independent board complete all as specified and directed.
6(d) All as per per item No 02 here-in-before but for one light point controlled by two Nos of2 way switchescomplete all as specified anddirected.
7All asper item No. 2 above butwiring with 2.5 Sqmm (Nominal area)PVCinsulated,unsheathed, multi stranded Copper conductor cable drawn in and including PVC rigid PVC conduit 25mm or higher sizewith all its fittngs and accessories for one 3 pin/6 pin 15 Amps socket out let point independent alongwith PVC insulated cable with multistranded copper conductor 2.5 Sqmm (nominal area) continuous earth wire, and connected to earth dolly including fixing of 1.20 mm sunk pressed steel terminal box/ MS modular boxe suitably flushedto wall with 3mm thick Hylum sheet cover/ white colour modular plate for housing switch, socket regulator etcfixed with screws & cup washers incl. making good complete all as specified and directed.
8Supply and FixingP/switch flush type 5/6 Amp SP one way complete all as specified and directed.
9Supply and Fixingin repairs P/switch flush type 5/6 Amp SP one way complete all as specified and directed.
10Supply and FixingP/switch flush type 5/6 Amp SP two way complete all as specified and directed.
11Supply and FixingP/switch flush type 15/16 Amp SP one way complete all as specified and directed.
12Supply and Fixingin repairs P/switch flush type 15/16 Amp SP one way complete all as specified and directed.
13Supply and Fixingceilingrose 2/3 terminals complete all as specified and directed.
14Supply and Fixingin repairs ceilingrose 2/3 terminals complete all as specified and directed.
15Supply and Fixinglamp holder PVC Angular/ pendent/ bakelite.complete all as specified and directed.
16Supply and Fixingin repairslamp holder PVC Angular/ pendent/ bakelite.complete all as specified and directed.
17Supply and Fixingin repairs Switch socket combination 5ampflush type complete all as specified and directed.
18Supply and Fixingin repairs Switch socket combination 2 in one 5 and 15 Amp flush type complete all as specified and directed.
19Supply and Fixingin repairs buzzer, capton ding dong, AC, 230V, sigle pole complete all as specified and directed.
20Supply and fixing bell push switch flush type complete all as specified and directed.
21Supply and Fixingsocket outlet ,3/5 pin 5ampflush type complete all as specified and directed.
22Supply and Fixingin repairssocket outlet ,3/5 pin 5ampflush type complete all as specified and directed.
23Supply and Fixingsocket outlet 2 in one, 3/5 pin5 and 15 Amp flush type complete all as specified and directed.
24Supply and Fixingin repairs socket outlet 2 in one, 3/5 pin5 and 15 Amp flush type complete all as specified and directed.
25Supply and Fixingin repairs Modular switches 1 way, 6 A, 1 module complete all as specified and directed.
26Supply and Fixingin repairsModular switches 1 way, 16 A, 1 module complete all as specified and directed.
27Supply and Fixingin repairsModular sockets6 A,-2/3 pin combined2 modulecomplete all as specified and directed.
28Supply and Fixingin repairs Modular sockets6 A/ 16 A,-2/3 pin combined2 modulecomplete all as specified and directed.
29Supply and Fixingin repairs Modular fan regulatorsstep type, 120 W, 2 module complete all as specified and directed.
30Supply and Fixingin repairsfan regulator resistance/electronic step piano type single phase 230 volt. complete all as specified and directed.
31Supply and Fixingin repairsHylem sheet 3mm thick of size 9"" X 11"" including cutting of sheet for fixing switch / socket. complete all as specified and directed.
32Supply and Fixingin repairsHylem sheet 3mm thick of size 8"" x 5"" including cutting of sheet for fixing switch / socket. complete all as specified and directed.
33Supply and Fixingin repairsHylem sheet 3mm thick of size 5"" x 5"" including cutting of sheet for fixing switch / socket. complete all as specified and directed.
34Supply and Fixingin repairsMCB SPN20 to 32 Amps240 volts.10kAcomplete all as specified and directed.
35Supply and Fixingin repairsMCB SP 6 to 32 Amps240 volts, 10 kA. complete all as specified and directed.
36Supply and Fixingin repairs MCB TPN 63 Amps,415V,10kA complete all as specified and directed.
37S &F in repair MCCB 16 kA,125Amp thermal magnetic and electronic earth leakage module complete all as specified and directed.
38Taking down unserviceable existing sub main wiring with aluminium conductorstranded cable upto 6 Sqmm single core including earth wire from existing conduit or wooden battens including taking out unserviceable wooden gutties etc, matching with the existing surfaces complete all as specified and as directed. .
39M & L Sub main wiring concealed type with two single core cable PVC insulated cable with 4.0Sqmm (Nominal area) multi stranded copper conductor cable 1100 volts gde incl earth continuity conductor using PVC insulatedcable of copper conductor of size 4.0 Sqmm connected to common earth dolly anddrawing into rigid PVC conduit with lock pattern incl. making good the disturbed surface complete all as specified and directed. (Note : PVC conduit and its accessories including 2 runs of cable 4 sq mm & 1 run of earth continuity conductor cable 4 sq mmunsheathed shall be measured and paid as single unit).
40M & L Sub main wiringconcealed type with two single core cable PVC insulated cable with6.0Sqmm (Nominal area) multi stranded copper conductor FRLS cable 1100 volts gde incl earth continuity conductor using PVC insulatedcable of stranded copper conductor of size6.0Sqmm connected to common earth dolly anddrawing into rigidPVC conduitsof 25 mm dia medium gradesize incl. making good the disturbed surfacescomplete all as specified and directed. (Note : PVC conduit and its accessories including 2 runs of cable 6 sq mm& 1 run of earth continuity conductor cable 6 sq mm unsheathed shall be measured and paid as single unit).
41S&F in replacement sheet metal enclosure DB"s 415 Volts, IP-42, vertical suitable for mounting MCCB"s, TPN,12way with 200 Amps rated copper bus bar complete all as directed by Engineer-in-charge.
42Supply and Fixingin repairs double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail single phase and neutral confirms to IS : 13032-1991 of 4 ways complete all as specified and directed.
43Supply and Fixingin repairs double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail single phase and neutral confirms to IS : 13032-1991 of 8 ways complete all as specified and directed.
44Supply and Fixingin repairs double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail single phase and neutral confirms to IS : 13032-1991 of 12 ways complete all as specified and directed.
45Supply and Fixingin repairs4 Pin CFL lamp 36Watt complete all as specified and directed.
46S & F in repairs 2 Pin CFL 18 W lamp/LED bulb thread type complete all as specified and directed.
47S&F in replacementLED fitting with PVC extruded battern 20 watt 4 feetWhite colour including dismentiling and taking down any type of FTL/LEDcomplete all as specified and directed.
48S&F in replacementLED fitting with PVC extruded battern 10 watt 2 feetWhite colour including dismentiling and taking down any type of FTL/LEDcomplete all as specified and directed.
49S&F in repairs building security light led type 25 W complete all as specified and directed.
50S&F 2"x 2" LED recess/ surface mounted fitting 36 Watt, 230V, withintegrated electronic driver high transcluent frosted diffuser, connector block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
51S&F 2"x 2"inverter LED 2x2 panel is CRCA powder coated and IP 20 with battery back up and functioning asper productTDS recess/ surface mounted fitting 36 Watt, 230V, withhigh transcluent frosted diffuser, connector block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
52S&F in repairs 4mm thick E-board tiles for insulation and acoustic purpose including aluminium snap grid with 25x25x1.5 mm thick tee section and 38x52x2 mm thick angle with hanging/suppoting arrangements as in false ceiling at bottom at spacing 60cm centre to centre including necessary GI cleats and 4mm dia GI wire as suspender fixed to ceiling not exceeding 1.20 mtr centre both ways with dash fasteners cmplete and making good disturbed surfaces including taking down old ceiling any type complete all as specified and directed.
53S&F in replacementof PVC non metallic casing caping of 25 mm sizewith accessories including dismentaling/takingdown of old unserviceable/broken PVC conduit/cashing caping fixed on surface/concealed inclduing making good the disturbedsurfacecomplete all as specified and directed
54Supply and Fixingin repairs flexible wire 23/0.0076 PVC insulated copper conductor twin core complete all as specified and directed.
55Taking down ceiling fans 1200/1400 mm sweep & removing/cleaning of dust properly, oiling and greasing of bearing including re-fixing and connecting up with all requisite accessories complete all as specified and directed.
56M & L Re-winding of burnt fan motor of 1200/1400 mm sweep including internally and externally cleaning of fans and removing the burnt coil and re-winding of fans by super enameled copper wire of appropriate size, make (ATLAS) or equivalent and re-assembling the fans and connecting with flexible copper wire of one mtr length and testing after repair complete all as specified and directed.
57Taking down exhaust fan of 450/300 mm sweep and removing/cleaning the dust properly including oiling and greasing complete all as directed.
58Re-winding of exhaust fan motor of 450/300 mm sweep with appropriate size of super enameled copper wire, including re-assembling the fans and connecting with flexible copper wire of one mtr length complete all as directed.
59Supply and Fixingin repairs Condenser 2.5 Mfd make universal/Usha /Bajaj/Epcos.
60Supply and Fixingin repairs Condenser 3.5 Mfd make universal/Usha /Bajaj/Epcos.
61Supply and Fixingin repairs bush of fans of any size complete all as directed.
62Supply and Fixingin repairsinsulating rubber real including Supply and replacing nuts, bolts with washers complete all as specified and directed
63Supply and Fixingin repairsshaft of fans (as per sample) of suitable size complete all as specified and directed
64Supply and Fixingin repairsof fan pins of suitable size for various type of fans / ceiling fans complete all as specified and directed.
65Supply and Fixingin repairs fan down rod made out of 15 mm dia medium grade GI pipe, Med grade including threading on both end of pipe, drilling holes etc. as required including primer complete all as specified and directed.
66Supply and Fixingin repairsfan conopy, suitable for various type ceiling fan all as per sample and directed.
67M&L for replacement and re-filling of glass wool as per norms of different type of geysers complete all as specified and directed by the Engr in Charge.
68Taking down of unserviceable bolt of existing geyser, M&L grouting of new bolt (tee type) at new place and refixing of geyser of any type and any capacity all as speified and directedby Engr in Charge.
69S&F in repairs heating element 2.0 KW as triangular type/ circular type asper sample all as directed by the Engr in Charge.
70S&Fonly new inner shell of geyser capacity 25/35 liters of suitable size made of copper sheet of 22 SWG complete with all suitable accessories complete all as specified and directed.
71M&L for replacement of bottom cover in two parts of MS sheets not less than 22 gauge and pre treated in finished in white stove enameled paint as per existing size gauge in the geyser of any capacity/size complete all as specified and directed.
72Supply only new safety pressure valve with vent to geysers as per latest ISI specification anddirected.
73M&L for Painting the outer surface of geyser capacity 25/35 ltrs as per original shade with two coats of synthetic enamel paint over a coat of primer by spray gun after scrapping the existing paint ,denting etc. filling depression with putty and refixing the geyser in position including water/electric connection and testing complete all as specified and directed.
74M&L for Brazing/ welding to inner copper tank at leaking spots up to five leakage of geyser of capacity 25/35/50 liters of any type and make of tank after checking up worn out nuts bolts and washers complete all as specified and directed.
75S&F assemblly of geyser 25/35/50 ltr.capacity as specified and directed by Engg. In charge.
76Supply and Fixingin repairs Indicator lamp with new indicating lamp round/square, rectangular type as required at site, SP 230Volt
77Supply and Fixingin repairsPVC connection flexibleheavy grade 45 cm long complete with chromium plated flair nuts with washers at both ends suitable for GI tubing 15 mm bore complete all as specified and directed.
78Supply and Fixingin repairs thermostat 0 to 90 degree, ISI marked, 15 Amps capacity automatic cut off at desired temp of suitable size for Geyser
79Supply and Fixingin repairs Plug top 15 AmpsMake Anchor or equivalent complete all as specified.
80Dismantling,inspection,repairing and re assembling after replacement ofUNSV parts ie circiut and all electronic controls etcfor homogeneous and shadow less light withmin temp rise complete all as specified and directed.making serviceable shadowless light fitting completefunction including testing after repair and replacement ofNote: The cost of OT bulb will be paid under item No 83 and the cost of other spares deemed to be included in the quoted rate.
81Dis assembling ,inspection,cleaning and servicing of 1.0 kVA UPS of OT/ICU backup at MH Bly and assembling including testing after making necessary repair/replacement of resistors,capacitors, transformer, PCB circuits, relays , batteries etc complete all as specified and directed. Note: The cost of batteries will be paid under item No . 76 The cost of other spares deemed to be included in the quoted rate.
82Supply only UPS batteries 12 V, 7 AH Make Exide/Amron/or equivalent complete all as specified and directed.
83M&L foropening ,inspection,cleaning and servicing of 2.5 kVA UPS of OT/ICU backup at MH Bly and assembling including testing after making necessary repair/replacement of resistors,capacitors,transformer,LM relays , PCB circuits , hardware of appropriate capacity match with existing UPS incl replacement of battery etc complete all as specified and directed. NOTE:- The cost of batteries will be paid under item No 78. The cost of other spares deemed to be included in the quoted rate.
84Supply only UPS batteries 12 V 65 AH Make Exide/Amron/or equivalent complete all as specified and directed.
85M&L foropening ,inspection,cleaning and servicing of5 kVA UPS of OT/ICU backup at MH Bly and assembling including testing after making necessary repair/replacement of resistors,capacitors,transformer,LM relays , PCB circuits , hardware of appropriate capacity match with existing UPS incl replacement of battery etc complete all as specified and directed. NOTE:- The cost of batteries will be paid under item No 80 . The cost of other spares deemed to be included in the quoted rate.
86Supply only UPS batteries 12 V 150 AH Make Exide/Amron/or equivalent complete all as specified and directed.
87Supply and fixing name plate light smart decorative light of min. 6W of make C&S, Surya, Crompton or equivalent complete all as specified all as directedby Engr-in-Charge.
88M&L foropening ,inspection,cleaning and servicing ofmovable light for backup at MH Blyincluding testing after making necessary repair/replacement ofspareparts ie resistors,capacitors,transformer,LM relays , PCB circuits , hardware of appropriate capacity match with existing light incl replacement of battery etc complete all as specified and directed. NOTE:- The cost of batteries will be paid under item No 80 . The cost of other spares deemed to be included in the quoted rate.
89M&L for earthing complete with galvanised steel earth plate electrode 600 x 600x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and connectingto main switch or switch boardcomplete and incl PCC masonry pit of 300x300x300mm interier diamentions in PCC 1:2:4 type B1 RCC cover with GI frame, charcoal and common salt 15cm in layers all round the earth plate, 15mm dia GIwatering pipe, a funnelwith wire mesh should be provided on top of watering pipe complete all as specifiedincluding testing after completion.
90Notes :-(i) For ser No. 02 to 44 itemsthe Contractor has to complete the work assigned for above items with in36 hours failing in which recovery at the rate 25 Rs. per day per complaint. (ii) For Serial No 51 to 56, 59 to 87: The Contractor has to complete the work assigned for above items with in60hours failing in which recovery at the rate 25 Rs. per day per complaint. (iii) The contractor has to maintain a separate complaint slip book and complaint register for attending complaint. The contractor rep have to collect daily complaint slip from the E/M complaint celland get them signed from user after completing the job and submit to E/M complaint cell.
91Repair to Split Type/Window Type AC 1/1.5/2.0 TON
92Maintenance and Servicingof split type air conditioner of capacity 1.5/2.0 TR of any make and type by removing , strip opening, cleaning the dust and dirt from the complete unit, cleaning of air filter, cleaning of condensingand cooling coil and complete outdoor and indoor unit using suitable mild cleaning agent and fresh water, blow drying using air blower, oiling/greasingof blower & condenser fan motor etc re-assembling, re-installing in the original position and testing for proper cooling and smooth functioning.
93Maintenance and Servicingof Window type air conditioner of capacity 1.0/1.5/2.0 TR of any make and type by removing , strip opening, and taking out the window type AC from the cabinet frame and cleaning the dust and dirt from the complete unit, cleaning of air filter, cleaning of condensingand cooling coil using suitable mild cleaning agent and fresh water, blow drying using air blower, oiling/greasingof blower & condenser fan motor etc re-assembling, re-installing in the original position and testing for proper cooling and smooth functioning.
94Takingdown/out unserviceablesealed/rotary/Reciprocating type compressor unitfromthe outdoor unit of Split type AC/ Window type ACs of makes-Carrier/LG/haier/blue star/Voltas and any other make of capacity 1/1.5/2.0 Toncapacityincludingflushingofcoolingsystem byNitrogen gas.
95S&F compressor(sealed unit)of followingcapacityinSplit type/window type Air Conditioner complete and testing on full load all as specified and as directed by Engineer-in-Charge
96(a)Reciprocating type1.5 Ton
97(b)Reciprocating type2.0 Ton
98(c)Rotterytype1.0 Ton
99(d)Rotterytype1.5 Ton
100(e)Rotterytype 2.0 Ton
101S&F in repair of following spares parts of Split type/Window type ACs of capacity 2.0/1.5/1.0 Ton including testing complete after dismantling of old respective unserviceable spares
102Supply, fixing , installation ,commissioning and testing of indoor unit complete with remote and valves of capacity 1.5 TR suitable for fixing up in the existing model ofoutdoor unit of Split ACs complete after disconnecting electrical connection and dismantling/ taking out indoorunit of split type ACs of any make and capacity from any placeandinstallation, commissioning and testing after recharging of refrigerant gas to another location including transportation cutting of hole on wall and making good of disturbed surface with matching colour/distamper all as directed by Engineer-in-Charge.
103All as Per Srl Item No 96 above but of indoor unit capacity 2.0 Ton
104S & F Remotesuitable for various makes of Split type/Window ACs for 1/1.5/2.0 Toncapacity Make: LG , Carrier, Voltas, Bluestar, Hitachi
105S & FCondenser motor of outdoor unit for 1.5/2.0 Ton capacity of AC as per existingmakes
106S & FIndoor motor of Blower for 1.5/2.0 Ton capacity of split AC as per existingmakes
107S & F Condenser PVC blade of fan motor for 1.5/2.0 Ton Split AC
108S & F SP plug and socket insheet steel enclosure includingSP MCB 32 AmpsMake : HPL/Havells/L&T
109S & FRunning capacitor50/2,/50/6 Mfd ofsuitablesize make Epcos/Asian/Max/Sharda or equivalent as per ISI for ACs
110S & F Running capacitor45 Mfd ofsuitablesize make Epcos/Asian/Max/Sharda or equivalent as per ISIfor ACs
111S & F Starting capacitor100/120 Mfd ofsuitablesize make Epcos/Asian/Max/Sharda or equivalent as per ISIfor ACs
112S & F Indoor capacitor of size 1.5 MFD/2 MFD suitable for 1.5/2.0 Ton AC
113S & F Swing motor suitable for indoor unit of 1.5/2.0 Ton Split type AC
114S & F Contactor suitable for 1.5/2.0 Ton AC as per make/size approved by Engr-in-Charge . L&T/C&S/SIEMENS
115S & F Copper tubing of size 3/8" including cutting and brazing all as directed by Engr-in-Charge
116S & F Copper tubing of size 5/8" including cutting and brazing all as directed by Engr-in-Charge
117S & F Copper tubing of size 1/4" including cutting and brazing all as directed by Engr-in-Charge
118S & F Copper tubing of size 1/2" including cutting and brazing all as directed by Engr-in-Charge
119S&Fthree core connection lead two single core,PVC insulated and sheathed Copper cable size 2.5 Sqmm including oneearthwire of full guagecomplete all as specified and as directed
120S & F Nitril vinyl insulation foam suitable for fixing with copper tube of size 3/8", 5/8" , 1/2" and 1/4" and packing with wide pvc tapes of black/white colour compete all as specified and directed.
121S & F Reverse valve suitable for 1.5/2 ton ACs including dismantling and reinserting of valve and refilling of reqd refrigerant and testing all as specified and directed by Engr-in-Charge
122S & F Shifting/Fixing by disconnecting electrical connection and dismantling/ taking out indoor and outdoor unit of split type air conditioning of any make and capacity from any placeandinstallation, commissioning and testing to another location including transportation cutting of hole on wall and making good of disturbed surface with matching colour/distamper all as directed by Engineer-in-Charge.
123S & FShifting/Fixing by disconnecting electrical connection and dismantling/ taking out window type air conditioning complete with frame cabinet of any make and capacity from any placeandinstallation, commissioning and testing to another location including transportation cutting of hole on wall and making platform complete with wooden strip/iron frame for fixing of Window AC Cabinet and making good of disturbed surface with matching colour/distamper all as directed
124Taking down unserviceable PCBs card with sensors of Split/Window type AC and refix the same after complete repair and testingas of Cap 1.5/2.0 ton as directed by Engr-in-charge.
125Supply and gas charging withrefrigerentgas required in any make and type of splitand window type ACs to itsfull capacity where less gas detected in the split type and window type air conditioners complete all as specified by Engr in charge
126Notes :- Tenderers may note that amount as given in schedule of credit will be deducted from the total amount to worked out the net contract sum at the time of Acceptance of tender.