Tender For Construction Of 08 Bedded Mahila Barrack At Bop Somagap Of 108 Bn Bsf Under Shq Bsf Jsmr_S _Sh_ Ei _ Fans., Jaisalmer-Rajasthan

Border Security Force-BSF has published Tender For Construction Of 08 Bedded Mahila Barrack At Bop Somagap Of 108 Bn Bsf Under Shq Bsf Jsmr_S _Sh_ Ei _ Fans.. Submission Date for this Tender is 27-04-2024. Barrack Tenders in Jaisalmer Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

43213138
Corrigendum : Tender For Construction Of 08 Bedded Mahila Barrack At Bop Somagap Of 108 Bn Bsf Under Shq Bsf Jsmr_S _Sh_ Ei _ Fans.
Open Tender
Indian
Rajasthan
Jaisalmer
27-04-2024

Tender Details

Tender For Construction Of 08 Bedded Mahila Barrack At Bop Somagap Of 108 Bn Bsf Under Shq Bsf Jsmr_S _Sh_ Ei _ Fans.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 25-Apr-2024 CORRIGENDUM/ADDENDUM TO TENDER NIT. Other 27-04-2024

Key Value

Document Fees
Refer document
EMD
INR 15846.0 /-
Tender Value
INR 7.92 Lakhs /-

BOQ Items

Name of Work: C/O OF 08 BEDDED MAHILA BARRACK AT BOP SOMAGAP OF 108 BN BSF UNDER SHQ BSF JSMR-S (SH: EI & FANS)
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. i) Group B
2Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
3Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
4Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (i)2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
5Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 6 sq. mm + 1 X 6 sq. mm earth wire
6Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel /PVC conduit as required. (i) 4X6 sqmm
7Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair(Make : Havells / Polycab/ R R KABEL / Finolex )
8Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
9Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (i) 20 mm
10Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
11Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm
12Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
13Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
14Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required.
15Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module(75 mm X 75 mm)
16Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch
17Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet
18Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet
19Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. TV antena socket outlet
20Supplying and fixing PVC batten/ angle holder including connection etc. as required.
21Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required
22Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Double door
23Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) 16 way Double door
24Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
25Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
26Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required.I) For 6 way, Double door TPN MCBDB
27Supplying and fixing Cable End Box (Loose wire box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. For 14 way, Double door SPN MCBDB
28Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
29Supplying and fixing call bell/buzzer suitablefor single phase 230 volts, complete as required as per the direction of engg -in- charges.
30Earthingwith GI earth pipe4.5 metre long x 40 mm dia including accessories and providing masonry enclosure with cover platehaving locking arrangement and watering pipe etc. (with charcoal or coke and salt)as required
31Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
32Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling etc as required.
33Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required
34Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
35Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
36Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
37Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
38Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
39Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc. as required
40Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
41PROVIDING AND FIXING CIRCULAR/ HEXAGONAL G.I. BOX FOR CEILING FAN CLAMP, OF INTERNAL DIA 140 MM, 73 MM HEIGHT, TOP LID OF 1.5 MM THICK G.I. SHEET WITH ITS TOP SURFACE HACKED FOR PROPER BONDING, TOP LID SHALL BE SCREWED INTO THE G.I. BOX BY MEANS OF 3.3 MM DIA ROUND HEADED SCREWS, ONE LOCK AT THE CORNERS. CLAMP SHALL BE MADE OF 12 MM DIA M.S. BAR BENT TO SHAPE AS PER STANDARD DRAWING. (DSR Civil-2014 item no. 10.18)
42Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.(a) 3.5X 25 sq. mm (28mm)
43Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. Direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc complete as required. (REX Polyextrusion / Jain Irrigation / Duraline / Avadh Polytube/ Gemini make) 63 mm dia (OD-63 mm & ID-51 mm nominal)
44Supplying and Laying of one number aluminium conductor, XLPE Insulated, PVC sheathed, armoured power cable of 1.1 kV grade , confirming to IS : 7098 (Part-1) 1988 of 3.5 X 25 sqmm in the existing HDPE/RCC/ HUME/ METAL pipe as required. (ISI marked Make Havells /Polycab/ Finolex /CCI /KEI /RR Kabel)
45Supplying and Laying of one number aluminium conductor, XLPE Insulated, PVC sheathed, armoured power cable of 1.1 kV grade , confirming to IS : 7098 (Part-1) 1988 of 3.5 X 25 sqmmin the existing masonry open duct , for loose connection etc as required. (ISI marked Make Havells /Polycab/ Finolex /CCI /KEI /RR Kabel)
46SITC of 240V, 50 HZ 1200 mm Sweep Ceiling Fan, having 02 Nos Canopy including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required of(make : Orient, model : Rapid Air/Bajaj/ usha/ Crompton/ Havells) including connection etc as required.
47SITC of 240V, 50 HZ 900 mm Sweep Ceiling Fan, having 02 Nos Canopy including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required of (Make : Havells,Model : Cool Breeze /Bajaj/Usha/Crompton)
48S/I/T/C of 20 Watt, 6500 K LED batten Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient with LED inbuilt driver (make : Havells, model :pride essential/CG/Bajaj/Philips) including connection etc as required.
49S/I/T/C of 10 Watt, Mirror light ,6500 K LED batten ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient with LED inbuilt driver (make : Havells, model : Elite LED Pride plus/CG/Bajaj/Philips) including connection etc as required.
50Supplying and fixing of10 Watt, 3 star rating (B-22 base) LED bulb(make : Havells/CG/Bajaj/Philips) .
51SITC of 300 mm Medium Duty Exhaust fan.complete with louvers and shutter etc, including connection, testing, commissioning etc. as required.(Make : Orient, model spring air medium duty exhaust fan/Havells/USHA/ Crompton/Bajaj)
52SITC of 6 Watt , 6500 K surface mounted round/Square shaped LED downlighter with durable Aluminium housingto give glare free light withdriver of HavellsModel TRIM COSMO SURFACE ROUND 6 Watt, 6000 Kor compatable make of Bajaj/Philips/CGi.c connection etc as required.
53Supplyingandfixingof30 wattledfloodlight having input240V ,50 Hz coremounting on wall &Energy saving, environmental friendly, long life etc as required . (Make Havells, model : No-CENTURA NEO/Crompton/Philips/HPL)etcasperdirectionofengineer-in-charge
54Supplying and fixing G.I. pipe of 40 mm dia meduim duty on surface /recessfor protection of UG cable etc. as required of ISI marked of make Jindal/ Hindustan / Prakash.
55SITC of 100 Amp/415 Volt busbar chamber in the existing wall, including connection etc as required as per direction of engg in Charge (Make- Benlo code BEBB100, or equivalent in Havells/HPL/L&T/C&S)
56Supplying and fixing 63 Amp, TPN MCB suitable for 240/415, 50 HZ, 10 KA breaking capacity in the existing MCB DB complete with connections, testing and commissioning etc. as required,( make Havells code- DHMGCTNF050 or euiavelnt in L&T/Siemens/legrand/Schenider )
57Supplying, Installation, testing and commissioning of following2kw off grid solar system having high efficiency Poly crystalline solar paneland 150 AH Lead acid solar battery (3 year replacement warranty ) & 3.5 KVA solar inverter. The whole solar panel system will mounted on suitableGI frame structure mounted on roof including connection complete installation on site etc as required as per direction of engg-in-charge. The complete work shall be supervised and certified by the manufacturers for satisfactory supply, erection, testing and commissioning . DETAILED SPECIFICATIONS 1. PHOTOVOLTAIC MODULE ( 06 Nos ) (i) Module Rating : Wp-335x6(25 years warranty) (ii)Module Type: Poly Crystalline (iii) Makes : WAAREE. /Tata BP Solar/Luminious / BHEL / CEL / Moserbear 2. BATTERY - 04 Nos (i) 150 Ah , 12 volt Battery Type: Solar Battery( 3 Years replcement warranty Battery) (ii) Make: luminious/ exide or simillar specification3.OFF GRID SOLAR INVERTER ACCESSORIES (i) Nominal Capacity: 3.5 KVA (3 years warranty)(ii) Makeof invertor : Eapro/luminus/exide simillar specification (iii)DCDB with SPD and DCMCB :1 Nos (iv) DC Cable6sqmm: 30 Mtr (v)AC Cable 2.5 sqmm: 20 mtr(vi) MC4 connector :12 Nos(vii) Fasteners , Cable Tie etc 4. STRUCTRUE(i) GI Structure including fastening with anchor bolton terrace as per site requirement
58SITC of 15 Ltrenergy effecient 5 star rated electrical Storage water Geyser with stainless steel tank suitable for 230 V, 50 HZ AC single phase supply with 05 years tank warranty and 02 year comprehensive warranty with adjustable thermostat/temp adjustable knoband making connection with heavy duty connection pipe etc. as required . (Make Crompton Product code ASWH 3015 or equivalent inBajaj/Jaquar /Havells)
59Providing and installation of single phase heavy industrial ductable air cooler (top/ down discharge as per site requirement) having ofsize1100 x 1100x 950 mm and air outlet size is 670 mmx670 mm along with duct and grill . The air cooler will have the following specifications :- Air flow 18000 CMH with cooling area capacity at about 1500 sqft(with duct) , motor 380 V/50 Hz. power 1.1 Kw fan type axial , water tank capacity 35 Ltrs , overload protection , dust filter,Body should be fabricated with engineeringplastic single moduled , light weight, UV resistant, rust proof, crack proof and weather proofincluding complete in all respect as required as per the direction of Engg-in-charge. Make Sky air coolers/ Symphony / Khaitan or its equivalent
60Supplying and making of ducting through 22 Gauge GI sheet with duct face of size18"x12", ducting will be insulated through high quality insulating material et as required as per the direction of engg-in-charge.
61Cutting of RCC wall/ Manually/ by meachanical means including stacking of steel bars and disposal of unservicable material and repairing of damaged wall after dismentaling/cutting including plastering and painting etc as required as per the direction of Engg-in-charge.
62Providing and fixing of angle iron stand of size50mmx50mmx5mm made of MS angle for duct cooler having size1100 x 1100 mm with 04 nos of legs of height 600 mm including primer and paintingof MS angle as per site requirement and installation of duct cooler, as per the direction of engg-in-charge. Make Jindal/TATA or its equivalent ISI marked
63Providing, Installation, testing & connection of 1 HP, 230 V, 50Hz self priming monoblock pump set having delivery and suction pipe dia (25mmx25mm) , head range(06-34) mtr discharge range (2700L/h-450L/h) in the existing 25 mm dia GI/CPVC pipe including connection etcas required as per the direction of engg-in-charge.
64Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittingswith one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 20 mm nominal outer dia pipes.
65Providing and placing on terrace on a platform of 1 feet (at all floor levels) polyethylene water storage tank, including floatvalve IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
66Add GST difference Multification factor (0.0633) on DSR Items (Srl no-01 to 43 and 64 to 65).
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail