Tender For Provision Of Electric Supply With Connected Items To Simulators At Cta Ground Under Ge (Central) Bangalore, bangalore-Karnataka

Military Engineer Services-MES has published Tender For Provision Of Electric Supply With Connected Items To Simulators At Cta Ground Under Ge (Central) Bangalore. Submission Date for this Tender is 13-05-2024. Electrical Products Tenders in bangalore Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

43198666
Corrigendum : Tender For Provision Of Electric Supply With Connected Items To Simulators At Cta Ground Under Ge (Central) Bangalore
Open Tender
Indian
Karnataka
bangalore
13-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Provision Of Electric Supply With Connected Items To Simulators At Cta Ground Under Ge (Central) Bangalore

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-May-2024 AMDT TO BOQ AND TENDER DOCUS BOQ 13-05-2024
2 01-May-2024 DATE Date 13-05-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 87000.0 /-
Tender Value
INR 43.50 Lakhs /-

Attachment

FileName File Description File Size
58979c7e-a788-41e7-a60a-dc25be5e8fa5.html Tender Notice 0 KB
BOQ_728184.xls Tender Document 0 KB
Tender86268.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: PROVN OF ELECTRIC SUPPLY WITH CONNECTED ITEMS TO SIMULATORS AT CTA GROUND UNDER GE (CENTRAL) BANGALORE
Sl. No. Item Description
1Supplying, installation, connecting, testing and commissioning of outdoor type distribution transformer of 160 KVA, 11/0.433 KV, 3 phase, 50 Hz, ONAN cooled oil immersed copper wound step down enrgy saving ( level 2) with latest AmmenmentIS:1180 (Part-I) : 2014,Amendment no.4 Mar 2021 floor mounted complete with first fillingISI marked filtered & dehydrated transformer oil and other standard fittings / accessories and 7 position off circuit tap changer (tapping range +/- 7.5% in steps of 2.5% each) with vector group DYN -11 complete all as specified and as directed by the Engineer in Charge. Note - (i) The ambient temprature shall be 48 degree Centigrade when measured by the resistance method after continuous full load run . (ii) The transformer shall be complete with standard fittings incl plinth foundation for Transformer mounting complete all as specified and directed by Engineer-in-Charge.
2Supply, install, testing & commissioning of outdoor type, welded stainless steel tank with IP-67 protection for SF-6 Tank and IP 54 protection for outdoor enclosure, both Side extensible type compact RMU, (DAS specification compact RMU), 12kV, 630 Amps, 21KA (VCB SF6 enclosed) as per IEC-62271, 4 Way RMU, i.e. 1 incoming+ 1 outgoing 630 A with copper Bus Bar consisting of 02 No’s SF6 insulated Motorized VCB of 11KV, 630Amp with overload and earth fault protection, capacitive voltage indication, Manometer, cable boots for VCB and castle key interlocked and necessary PCC foundation work including providing MS channel and MS angle as per manufacturer recommend along with bottom cable entry and front cable termination of suitable single run 3core 120sqmm HT cable with following specifications complete all as specified and as directed.
3(i) A01 as incoming VCB, A02as Outgoing VCB with three position isolator /earthing switch, bus bars, interlocking earth bars and stored spring energy mechanism. (ii) Stored energy mech for manual operation - 01 No. (iii) Set of 03 No’s Ring core protectionDual core CTs of suitable ratio as per feeder load, 2.5 VA, Class 1.0- 01 set in each breaker. (Transformer rating 2MVA) Capacitive voltage indication fixed type VPIS 9- 15KV - 01 No in each breaker
4(iv) Control voltage motor 24 DC-01 Nos each Breaker (v) Self powered OC+EF Protection relay type as per manufacturer recommended with rechargeable - 01 No in each breaker (vi) Master trip relay-01Nos each breaker (vii) Space heater (230VAC)- 01 Nos each breaker.
5(viii)One No Potential Transformer (PT) three phase, dry type (resin cast) fixed type 11 KV/110 VOLTS, 25 VA burden, accuracy class 1.0 (ix) Multi function meter for each breaker. (x) Under/over Voltage Relay each breaker. (xi) Impluse withstand voltage: To earth and between phases: 75KV Insulation level:-Power frequency 1 min:28 Kv
6(xii) Enclosure:CRCA sheet powder coated with Siemens grey shade IS 632 Front Cover: CRCA sheet powder coated with Siemens grey shade RAL 7035 Cable Cover: CRCA sheet powder coated with Siemens grey shade RAL 7035
7(xiii) Cable bushings interface C (400 bolted) , 630A (xiv) Bushings outside cone interface C for connection of external busbars 2x12V DC battery + charger scheme R-Y-B phase indication. Additional equipment delivered separately or mounted in respective panel.Set of coupling bus bars along with suitable coupling kit - 01No, Operating Handle - 01 No
8Design, fabricate, supply, testing and commisioning of APFC PANEL WITH MPP-H CAPACITOR AND MCCB AS INCOMER of capacity75 KVAR with(25 x 3) and on line display PF and error status system with intell VARS automatic PF panel with MD-XL type as incomer auto +manual option free stainding floor mounted outdoor type made out of 3 mm thick CRCA sheet steel with IP 42 degree protection powder coated micro processor based APFC relay with auxelary contactors and suitable conductor,each settings incl suitable size of aluminium busbar,LED type indicating lamp,pannel mounting volt meter 0-500 V,Ammeter suitable range alongwith 3 nos of suitable rating resin cast CTS and selector switches duly prewired and pannel wiring with PVC insulated copper conductor of size 1.5 sqmm with necessary 440 V caution board,number ferruling and labelling etc complete with standard fittings complete all as specified and directed by Engineer-in-Charge
9Supply and laying ,Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wall,XLPE insulated,screened,PVC bedded,galvanised steel strip or wire armoured,electric power cables (heavy duty) with aluminium conductor,11000 Volts Earthed,grade cross sectional area95 sqmm x 3 Core, and required aluminium cable lugsall as specified and directed.
10Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wall,XLPE insulated, armoured,electriccables (heavy duty) with aluminium conductor,1100 Volts Earthed,grade cross sectional area95 sqmm x 3.5 Core, and required aluminium cable lugsall as specified and directed.
11Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wall,XLPE insulated, armoured,electriccables (heavy duty) with aluminium conductor,1100 Volts Earthed,grade cross sectional area35 sqmm x 3.5 Core, and required aluminium cable lugsall as specified and directed.
12Material and labour of Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-64 (12.0 metres long)complete all as directed by Engineer-in-Charge.
13Material and labour of Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as directed by Engineer-in-Charge.
14Material and labour of Triple pole, mechanically operated,mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps,GOD of 12 insulator type complete all as directed by Engineer-in-Charge
15Material and labour of Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp all as specified and directed by Engineer-in-Charge.
16Material and labour for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size,for HT, 25x20cm size all as specified and directed by Engineer-in-Charge.
17Design, fabricate, supply, testing and commisioning of CPRI approved factory made LT Panel Board double door, out door type fabricated out of 3.15mm thick CRCA sheet steel for outer body and 3.00mm thick CRCA Sheet for inner partition walls, independent cabinate with cabinate doors for MCCBs, Bus Bars, cable trays, metering equipment,vertical type floor mounted on angle iron frame of ISA 45x45x5mm with minimum height of legs 45 cm, minimum IP-54 protection, comprising of solid aluminium bus bar 4 strips suitable of 400 Amps, suitablily grouted to PCC complete with internal wiring, epoxy powder coated, connections of cable ends with suitable size of aluminium cable lugs with the following accessories all as specified and directed by Engineer-in-Charge.
18(a) INCOMING (i) MCCB 200 Amps, 4 Pole, 415 V, 36 KA (ICS=ICU 100%) - 01 No (b) OUTGOING (i)MCCB 100-160 Amps, 4 Pole, 415 V, 25 KA - 02 Nos (ii)MCCB 63 Amps, 4 Pole, 415 V, 25 KA - 02 Nos (iii)MCB SPN 32 Amps-01 Nos(iv)Digital volt meter of size 4"x4"- 01 No(v) Selector Switch for Amp/Volt Meter - 02 Nos(vi) Current Transfer (CT)-3 Nos (vii) Phase indicator lamp (RYB) set of three - 01 No
19Excavation in trenches n. exc 1.5 mtr wide and n. exc 1.5 mtr depth for pole / cable / foundation etc including getting out in soft /loose soil complete all as specified and directed.
20Returning, filling in, approved earth including spreading, levelling, watering and well ramming in layers n.exc 25 Cm thick after cable are laid and tested complete all as specified and directed.
21Removing excavated material / surplus soil to a distance not exc. 50 mtrs & deposited where directed at a level not exc.1.5 mtr above the ground level complete all as specified & directed.
22M&L for PCC cable cover class HV type 1 flat size 300 mm x 180 mm x 40 mm, ISI marked across the cable for protection of cable after sand cushioning complete all as specified & directed.
23Supply and laying sub class brick,well burnt laid breath wise along with the length of cable laid in trenchover sand cushioning laid for cable protection all as specified and directed.
24Supply and laying dry river sand for cable cushioning in trenches to required width at bottom and top of cable incl spreading, levelling, watering and consiolidation complete all as specified and directed.
25M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregates) as in foundation filling and mass concrete for poles all as specified and directed by Engr-in-Charge.
26M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregates) as in foundation filling and mass concrete including form work for poles all as specified and directed by Engr-in-Charge.
27M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in coping etc including form work for poles all as specified and directed by Engr-in-Charge.
28M & L for HT/LT Cable route indicator/marker made of mild steel size of 35 x 35 x 5 mm with standar length 16 inches complete all as specified and directed by Engr-in-charge.
29M&L for steel tubing galvanised, light grade complete with fittings laid in trenches/ fixed along with poles etc as protection to cables of size 80 mm dia bore complete all as specified and as directed.
30M & L for road cutting incl excavation in trenches for laying HT/LT UG cable in pipe not exc 45 cm wide and n.exc 90 cm depth or as per site requirementmaking good the disturbed surfaces with cement concrete (1:3:6) type C-1 and top surface neatly finished as per existing to match with the existing complete all as specified .
31Providingtrenchless bore using using ultra sounding technique and necessary machine bore of pipe size 200 mm dia suitable for 0.4 mpa working pressure mechanical numatic drilling equipment for passing water pipe line upto 200 mm dia under the existing bituminous/WBM road/PCC hard standings, depth range not less than 1.0 mtr and upto 1.5mtr and making good to the distrubed surfaces of road to match with its existing specifications all as specified and as directed by engr-in-charge at site. Note : 1. Quoted rates deems to be inclusive of transportation charges of Drilling machine, connected accessories and passing pipe through bore complete with required accessories. 2. Pipe will be measured and paid separately. 3. Any damage to MES assets caused during trenchless bore shall be recitfied by the contractor at his own cost.
32M&L for brick work with fly ash bricks, straight or curved on plan exc 6 mmean radius built in CM (1:4) as in foundation of equipment, platform, ramp, supporting pillars of pipes incl demolistion of existing brick work built in cement mortar complete all as specified and directed.
33M&L for plastering in CM (1:4) 10 mm thick on fair faces of brick work or concrete surface/cable duct/floor complete all as specified and directed.
34M&L MS angles as fencing port, struct cutting tops in shape incl all necessary drilling, notching and reveting etc and similar work confirming fe 310-0 pr fe 4120-0 including prepration of steelSurface of one coat of red oxide and two coat of synthetic enamel paintall as specified and directed.
35M&L for structural MS frame work half round or other stock section including securing posts and stuts in fencing, frame work for gates of substations, base frame for equipments including securing bolts, posts and sturts in fencing including cutting and makeing shapes as desired, drilling holes, notching for wire cut to size and made to the exisitng shape suitable for fixing MS chequred duct covers / door panels, including nuts, bolts and washers, welding / bracing works, bendingcold or hot drilling holes for bolts in any shapeetc flat iron fillets (for securing wire mesh etc)all necessary drilling, bolting or riveting etc and similar work confirming to Fe-290 Gde E-165 including onecoat of primer and two coats of synthetic enamel paint to the entire steel surfaces all as specified and directed.
36M&L for chain link MS galvanised fencing including lines wires, dia of chain link n less than 3.5 mm any mesh any size any type to any type strands rails, straining bolts etc all as specified and directed by Engineer-in-Charge.
37S&F mild steel screw bolt (mechine made) with hexagonal or square, head, n.exc 5 cm but n.ecx 10 cm dia all as specified and directed by Engineer-in-Charge.
38M&L TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and includingmild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as directed.
39S&F galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossing with and provision of galvanised mild steel wire staples or steel pins etc as directed.Note -Each line of horizontal/vertical/diagonal wire to be measured for purpose of payment.
40M&L for laying 20 mm graded stone aggregate & stone dust in substations insuch a way that after removing of unwanted grass from substations and then levelling at zero level and laying of stone dust of 50 mm thick at an initial layer and then laying of 25 mm gaded stone aggregate 100 mm thick over the stone dust. The quoted rate also includes cleaning and levelling and filling of sub station before laying aggregate. The complete work shall be as decided and directed by engr in charge.
41S&F of cable jointing Kit 11 KV (earthed) grade cable for end terminationheat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 95 sqmm complete all as specified and as directed.
42S&F of cable jointing Kit 11 KV (earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 95 sqmm complete all as specified and as directed.
43Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to GI Strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15 mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for liftingmade out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail