All India Institute Of Medical Sciences-AIIMS has published Tender For Re- Insulation Of Hvac Pipeline And Duct In Various Ward, Corridor In Ipd At Aiims Patna. Submission Date for this Tender is 07-05-2024. HVAC Tenders in patna Bihar. Bidders can get complete Tender details and download the document.




Tender Notice

43191693
Tender For Re- Insulation Of Hvac Pipeline And Duct In Various Ward, Corridor In Ipd At Aiims Patna
Open Tender
Indian
Bihar
patna
07-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Re- Insulation Of Hvac Pipeline And Duct In Various Ward, Corridor In Ipd At Aiims Patna

Key Value

Document Fees
INR 1500 /-
EMD
INR 265100.0 /-
Tender Value
INR 1.32 Crore /-

Attachment

FileName File Description File Size
b033dc4f-b608-4053-b989-622da47f7951.html Tender Notice 0 KB
BOQ_845323.xls Tender Document 0 KB
tenderdoc.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: Re- Insulation of HVAC pipeline and duct in various ward, corridorin IPD at AIIMS Patna.
Sl. No. Item Description
1Supplying, laying,fixing, testing and commissioning of following thickness closed cell elastrometric nitrile rubber of class ‘O’ applied by adhesive confirming to standard specifications, as per specifications and as required complete in all respect.(duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK)make- Armacell, k- Flex,and Adhesive - SR-998 Insulation with nitrile rubber of thickness 32mm on existing pipe
2Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.25 mm nitrile insulation
3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.25 mm nominal outer dia Pipes
4Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core
5Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core
6Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick
7With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works
8Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : New work (two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution
9Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes inCement mortar 1:6 (1 cement : 6 coarse sand)
10Cement Plaster(Fine sand) 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand)
11Cutting and welding of existing pipe line for shiting to provide space for installation of PUF i/c providing necessary arrangement asM S support, hangers, pipe,bendsetc as reqd.
12SITC of0.63mm aluminium sheet cladding complete on existing all size HVAC PIPE Line etc as reqd (Pipe aluminium Cladding 0.63mm )
13SITC of fire redrant canvas cloth 2mm thick( including nut- bolts ,strip etc is required)
14SITC of STAR BOND1mm thick cotton cloth on 2or more coat on existing HVACpipe line( including adhesive-star bond, colouretc required arrangement)
15Removing of Insulation , and cleaning of rust etcin pipe line/Duct
16Supplying, laying/ fixing, testing and commissioning of following thickness insulation with fire retardant quality expandedpolyuthrane Foam (PUF) moulded pipe section of minimum density 36(+/-2) kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date in folowing pipe line section i/c necessary arrangemnet of scofolding/ladder etc as reqd 25 mm dia (Thickness of PUF insulation 30mm)
17Supplying, laying/ fixing, testing and commissioning of following thickness insulation with fire retardant quality expandedpolyuthrane Foam (PUF) moulded pipe section of minimum density 36(+/-2) kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date in folowing pipe line section i/c necessary arrangemnet of scofolding/ladder etc as reqd32 mm dia (Thickness of PUF insulation 30mm)
18Supplying, laying/ fixing, testing and commissioning of following thickness insulation with fire retardant quality expandedpolyuthrane Foam (PUF) moulded pipe section of minimum density 36(+/-2) kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date in folowing pipe line section i/c necessary arrangemnet of scofolding/ladder etc as reqd 40 mm dia (Thickness of PUF insulation 30mm)
19Supplying, laying/ fixing, testing and commissioning of following thickness insulation with fire retardant quality expandedpolyuthrane Foam (PUF) moulded pipe section of minimum density 36(+/-2) kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date in folowing pipe line section i/c necessary arrangemnet of scofolding/ladder etc as reqd50 mm dia (Thickness of PUF insulation 50mm)
20Supplying, laying/ fixing, testing and commissioning of following thickness insulation with fire retardant quality expandedpolyuthrane Foam (PUF) moulded pipe section of minimum density 36(+/-2) kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date in folowing pipe line section i/c necessary arrangemnet of scofolding/ladder etc as reqd65 mm dia (Thickness of PUF insulation 50mm)
21Supplying, laying/ fixing, testing and commissioning of following thickness insulation with fire retardant quality expandedpolyuthrane Foam (PUF) moulded pipe section of minimum density 36(+/-2) kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date in folowing pipe line section i/c necessary arrangemnet of scofolding/ladder etc as reqd80 mm dia (Thickness of PUF insulation 50mm)
22Supplying, laying/ fixing, testing and commissioning of following thickness insulation with fire retardant quality expandedpolyuthrane Foam (PUF) moulded pipe section of minimum density 36(+/-2) kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date in folowing pipe line section i/c necessary arrangemnet of scofolding/ladder etc as reqd100 mm dia (Thickness of PUF insulation 50mm)
23Supplying, laying/ fixing, testing and commissioning of following thickness insulation with fire retardant quality expandedpolyuthrane Foam (PUF) moulded pipe section of minimum density 36(+/-2) kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date in folowing pipe line section i/c necessary arrangemnet of scofolding/ladder etc as reqd125 mm dia (Thickness of PUF insulation 50mm)
24Supplying, laying/ fixing, testing and commissioning of following thickness insulation with fire retardant quality expandedpolyuthrane Foam (PUF) moulded pipe section of minimum density 36(+/-2) kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date in folowing pipe line section i/c necessary arrangemnet of scofolding/ladder etc as reqd150 mm dia (Thickness of PUF insulation 75mm)
25Supplying, laying/ fixing, testing and commissioning of following thickness insulation with fire retardant quality expandedpolyuthrane Foam (PUF) moulded pipe section of minimum density 36(+/-2) kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date in folowing pipe line section i/c necessary arrangemnet of scofolding/ladder etc as reqd 200 mm dia (Thickness of PUF insulation 75mm)
26Supplying, laying/ fixing, testing and commissioning of following thickness insulation with fire retardant quality expandedpolyuthrane Foam (PUF) moulded pipe section of minimum density 36(+/-2) kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date in folowing pipe line section i/c necessary arrangemnet of scofolding/ladder etc as reqd250 mm dia (Thickness of PUF insulation 75mm)