Tender For Renovation Of Room In Building E-22 & E-23 (Iind Floor) And E-26 (Iv Floor) At Olf Dehradun., dehradun-Uttarakhand

India Optel Limited-agecode007 has published Tender For Renovation Of Room In Building E-22 & E-23 (Iind Floor) And E-26 (Iv Floor) At Olf Dehradun.. Submission Date for this Tender is 07-05-2024. Building Repair Tenders in dehradun Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

43170638
Tender For Renovation Of Room In Building E-22 & E-23 (Iind Floor) And E-26 (Iv Floor) At Olf Dehradun.
Open Tender
Indian
Uttarakhand
dehradun
07-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Renovation Of Room In Building E-22 & E-23 ( Iind Floor ) And E-26 ( Iv Floor ) At Olf Dehradun.

Key Value

Document Fees
Refer document
EMD
INR 97200.0 /-
Tender Value
INR 48.58 Lakhs /-

Attachment

FileName File Description File Size
791628d8-7618-41cd-95e3-37c54e8379ea.html Tender Notice 0 KB
ATTACHMENT.pdf Tender Document 0 KB
BOQ_211833.xls Tender Document 0 KB
Tenderdocuments.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: Renovation of room in building E-22 & E-23 (IInd floor) and E-26 (IV floor) at OLF Dehradun.
Sl. No. Item Description
1Shifting of existing machines, tables, test stands, Almirah, test panel & other accessoriesto the specified location & re-shifting/re-fixingof same in original location in shop floor after completion of work.
2Removal of existing old PVC sheet fromfloor surfaces and removal of old worn outwooden batten and plywood from wall surfaces including disposal to CS premises within 500 mt distance, as directed by the Engg in Charge.
3Supply and fixing Aluminium Composite Panel consisting of two layers of aluminium skins sandwiching and laminating thermoplastic core, on interior walls over steel grid. The panels should be supplied with thickness 3 mm. Minimum thickness of aluminiuml 0.2 mm(Each skin). Surface coating of polyester, colour as directed by the Engineer-In-Charge. The panels shall be fixed in flat or curved shape as directed over the steel grid with the screws in such a way that the minimum size gap is producted in the joints and the screws are consealed or not visible . The joints and screw holes if any on the exposed surface of the panels shall be sealed properly with silicon based filler, transparant or of approved colour so as to give smooth, flush and jointfree look. Necessary openings shall be provided for doors, windows, Air Conditioing (AC) ducts, etc. and panels shall also be fixed on the sils/ jambs/ reveals. The pannels shall be provided in single length wherever possible and joints shall be provided only where necessary as directed by Engineer-In-Charge. All the cutting/ wastage shall be borned by the contractor. Make of the Aluminium Composite Panels- ALSTONE, VIVA, ALSTRONG, ALUCO BOND, ALEX PANELS, ALUPAN, ALUBOND, RYNOBOND.
4S&F Three phase plug with top in box 25 amp for machine power .
5S&F Banana socket male & female.make cona/havells/ssk only
6Dismantling of Aluminium partition frame (without Glass) andre-fixing in other opening at same location.
7S&Fof LED tube light 20 watt,2100 lumens,230 volt, 50 Hz cool white 4 feet,make-compact/ havells/philips only.
8Repairing of existing 3 tube light fitting sets in AC areas with cleaning of roof glass by glass cleaner and replacing(bipin)side holder of tube light.
9Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.
10Rendering 12 mm thick cement plaster in ratio 1:4on fair faces of brick work or concrete surface.
11Preparation of old plastered unplastered wall surface (scrapping down smokesoot, moulds, moss and efflorescent salts and trading oil and greasy spoots and providing wall putty where required) and applyingIst coat and subsequent coat (Two Coat)of distemper oil emulsion on walls complete all as specified and directed.
12Preparation of old plastered unplastered ceiling surface (scrapping down smokesoot, moulds, moss and efflorescent salts and trading oil and greasy spoots and providing wall putty where required) and applyingIst coat and subsequent coat (Two Coat)of distemper oil emulsion on ceiling complete all as specified and directed.
13S&F Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
14Prepration of new steel surface of any description over 10 cm grith or width and applying two coat ofsynthetic enamel (ordinary tint) after priming with red oxide zink chrome.
15S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
16Powder coated aluminium door shutters (minimum thickness of powder coating 50 micron), aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges or slider,sliding wheel, anodised aluminum snap beading screws etc. complete all as specified.
17S&F Brass Mortice lock, vertical type, 2 leaver size 100 mm including escutcheon plates and two keys.
18Sheet glass of thickness 4.8 mm, ordinary quality and glazing with oil putty/beading in exc 0.5 sq. m in each pane.
19Taking out old serviceable glass of any description, from old wooden or metal frames, or stone,concrete or brick surrounds, any thickness or size; hacking out old putty or removing beads etc, including making good breakages in taking out & cleaning of glass and handlingfor reuse.
20fixing only Sheet glass of any thickness, ordinary quality and glazing with oil putty/beading/seal including all accessories such as rubber seal etc.inexc 0.5 sq. m in each pane.
21PVC tiles/ sheets of 2 mm thickness, laminated plain coloured, marbled mosaic or mottled finish, laid with approved rubber based adhesive in floors.
22Removing building materials etc. to a distance of 500 m or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination.
23Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc.
24Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring in Brick walls etc., and making good, cutting not exc 10 cm girth.
25Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. in Stone concreteBlock or slabswalls and making good, cutting not exc 10 cm girth.
26S & F of sheet metal enclosures(TPN) for DB"S 12 way, when 3pole MCCB is used as incomer & MCBs TP are to be used as outgoing, double door 415 volt, tripple pole and nutral,IP 54 with 200 amp rated TP copper busbar (Latest version of legrand/Havells/Siemens make) only
27S & F of moulded case circuit breaker MCCB-125A, 3Pole, 415 V. fixed type, with breaking capacity 16 KA. (Latest version of legrand/Havells/Siemens make) only
28S & F of three pole miniature circuit breaker (MCB TP), 415V, 10KA, "C" curve, current carrying capacity 63 Amp(Latest version of Legrand/Havells/Siemens make) only in the DB complete with connection testing and commissioning.
29S&F of sheet metal enclosure (SPN)Single pole & neutral double door 12 way,IP 54, 200 amp rated copper busbar when MCBs to be used (Latest version of Legrand/Havells/Siemens make) only in the DB, complete with connection testing and commissioning.
30Supply and fixing of miniature circuit breaker (MCB) 32 AMP, 240V, 10KA "C" curvesingle pole(Latest version of Legrand/Havells/Siemens make) onlyin the MCB DB complete with connection testing and commissioning.
31Supply and fixing of miniature circuit breaker (MCB)DP(SPN) 63 AMP, 240V, 10KA "C" curvesingle pole(Latest version of Legrand/Havells/Siemens make) onlyin the MCB DB complete with connection testing and commissioning.
32S&F of point wiring of One light point or one fan point controlled by one switch with 1.5 sq mm single core FRLS PVC insulated sheathed Cable, multi stranded copper conductor connected with suitable size of copper lugs-ring tong or bottle type end connector and drawn through and including heavy duty,KNT/Polycab non rigid PVC concealed conduit 25 mm dia or higher complete all PVC conduit accessories such as socket, elbow, junction box bell mouthreducer bend and flexible conduit fittings etc , and pipe hooks/saddles, ISI markedincluding 1.0sq mm multi stranded copper conductor PVC insulated green in coloras continuous earth conductor connectto common earth and earth dolly with all accessories complete all as specified and directed.
33Add to item at Sl. No. 32 above for each additional light point on the same switchcircuit.
34M&L for Wiring for One 3 pin socket outlet 5 amps on the same board with other switches, with cables 1.5 sq.mm sizeFRLS PVC insulated sheathed Cable, multi stranded copper conductor connected with suitable size of copper lugs-ring tong or bottle type end connector and drawn through and including heavy duty,KNT/Polycab non rigid PVC concealed conduit 25 mm dia or higher complete all PVC conduit accessories such as socket, elbow, junction box bell mouthreducer bend and flexible conduit fittings etc , and pipe hooks/saddles, ISI markedincluding 1.0sq mm multi stranded copper conductor PVC insulated green in coloras continuous earth conductor connectto common earth and earth dolly with all accessories complete all as specified and directed.
35M&L for Wiring for circuit/submain PVC conduitwith 2x2.5 sq. mm+1x2.5 sq.mm earth wire of FRLS, PVC insulated copper conductor, single core cable,make Havells/plaza/finolex(IS:694-1992) with suitable size of copper lugs-ring tong or bottle type end connector and drawn through and including heavyduty,KNT/Polycab non rigid PVC concealed conduit 25 mm dia or higher complete all PVC conduit accessories such as socket, elbow, junction box bell mouthreducer bend and flexible conduit fittings etc , and pipe hooks/saddles, ISI markedincluding 1.0 sq mm multi stranded copper conductor PVC insulated green in coloras continuous earth conductor connectto common earth and earth dolly with all accessories complete all as specified and directed.
36M&L for Wiring for circuit/submain PVC conduitwith 4x4.0 sq. mm +1x4 sq. mm earth wire of FRLS, PVC insulated copper conductor, single core cable,make Havells/plaza/finolex(IS:694-1992) with suitable size of copper lugs-ring tong or bottle type end connector and drawn through and includingheavyduty,KNT/Polycab non rigid PVC concealed conduit 25 mm dia or higher complete all PVC conduit accessories such as socket, elbow, junction box bell mouthreducer bend and flexible conduit fittings etc , and pipe hooks/saddles, ISI markedincluding 1.0 sq mm multi stranded copper conductor PVC insulated green in coloras continuous earth conductor connectto common earth and earth dolly with all accessories complete all as specified and directed.
37M&L for Wiring for circuit/submain PVC conduitwith 4x6.0 sq. mm +1x6 sq. mm earth wire of FRLS, PVC insulated copper conductor, single core cable,make Havells/plaza/finolex(IS:694-1992) with suitable size of copper lugs-ring tong or bottle type end connector and drawn through and including heavyduty,KNT/Polycab non rigid PVC concealed conduit 25 mm dia or higher complete all PVC conduit accessories such as socket, elbow, junction box bell mouthreducer bend and flexible conduit fittings etc , and pipe hooks/saddles, ISI markedincluding 1.0 sq mm multi stranded copper conductor PVC insulated green in coloras continuous earth conductor connectto common earth and earth dolly with all accessories complete all as specified and directed.
38M&L for Wiring for circuit/submain PVC conduitwith 2x4.0 sq. mm +1x4 sq. mm earth wire of FRLS, PVC insulated copper conductor, single core cable,make Havells/plaza/finolex(IS:694-1992) with suitable size of copper lugs-ring tong or bottle type end connector and drawn through and including heavyduty,KNT/Polycab non rigid PVC concealed conduit 25 mm dia or higher complete all PVC conduit accessories such as socket, elbow, junction box bell mouthreducer bend and flexible conduit fittings etc , and pipe hooks/saddles, ISI markedincluding 1.0 sq mm multi stranded copper conductor PVC insulated green in coloras continuous earth conductor connectto common earth and earth dolly with all accessories complete all as specified and directed.
39S & FModular Metal flush box 6 module
40S & FModular Metal flush box 3 module
41S & FModular Metal flush box 4 module
42M & L Modular switch 1 way 6A, 1 module
43Modular switch 1 way 16A, 1 module
44S & F Modular Socket, 6A - 2/3 pin combined 2 module,
45S & F Modular Socket 6A/16A - 2/3 pin combined 2 module.
46S & Fof modular White cover plate with frame, 6 module .
47S & Fof modular White cover plate with frame, 4 module .
48S & Fof modular White cover plate with frame, 3 module .
49M& L PVC rectangular block for mounting, switches, sockets,fan regulator etc. with 3 mm thick plastic laminated sheetcover of size 100 mm x 100 mm and 50 mm deep.
50M& L PVC rectangular block for mounting, switches, sockets,fan regulator etc. with 3 mm thick plastic laminated sheetcover of size 200 mm x 150 and 50 mm deep.
51M& L PVC rectangular block for mounting, switches, sockets,fan regulator etc. with 3 mm thick plastic laminated sheetcover of size 175 mm x 100 mm and 50 mm deep.
52Supplied & fixed Rigid non-metallic PVC conduit 25 mm in dia exclusive of boxes (junction/terminal) but inclusive of all bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.
53M & L Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground
54M & L Earthing complete with copper plate 60×60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing lead buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion