Military Engineer Services-MES has published Tender For Provision Of Deficient Md Accommodation For Officers At Hq Eac (U) Af Under Ge (I) (Af) Shillong. Submission Date for this Tender is 16-05-2024. Building Work Tenders in shillong Meghalaya. Bidders can get complete Tender details and download the document.




Tender Notice

43163479
Tender For Provision Of Deficient Md Accommodation For Officers At Hq Eac (U) Af Under Ge (I) (Af) Shillong
Open Tender
Indian
Meghalaya
shillong
16-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Provision Of Deficient Md Accommodation For Officers At Hq Eac (U) Af Under Ge (I) (Af) Shillong

Key Value

Document Fees
INR 3000 /-
EMD
INR 962500.0 /-
Tender Value
INR 12.75 Crore /-

Attachment

FileName File Description File Size
0d0db8cb-86de-418c-be46-17a8595ae827.html Tender Notice 0 KB
BOQ_727688.xls Tender Document 0 KB
Main_Drg.rar Tender Document 0 KB
TD_1.rar Tender Document 0 KB
TD_2.rar Tender Document 0 KB
TENDER.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work:PROVN OF DEFICIENT MD ACCN FOR OFFICERS AT HQ EAC (U) AFUNDER GE (I) (AF) SHILLONG
Sl. No. Item Description
1NOTE (Applicable for all Parts/ Items):-The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
2SCHEDULE "A" Part - I (BUILDINGS/STRUCTURES) (Note:This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.5 signifies this fact only.)
3Construction ofOne Block of 12 Dus for Offrs (Sqn Ldr and above)instilt +4 configuration withvehicle parking/garages in ground floor, RCC terrace tank for fire fighting of 25000 litres capacity, RCC framed structure complete all as specified and as shown on drawings.
4Construction of Garbage Bin complete all as specified and as shown on drawings.
5SCHEDULE "A" PART- II SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK Details of prepriced Schedule is given in tender documents.
6SCHEDULE "A" PART- III (INTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents.
7SCHEDULE "A" PART- IV (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
8SCHEDULE "A" PART- V (ROADS) Details of prepriced Schedule is given in tender documents.
9SCHEDULE "A" PART- VI ( SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents.
10SCHEDULE "A" PART- VII (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents.
11SCHEDULE "A" PART- VIII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
12SCHEDULE "A" PART- IX (EXTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents.
13SCHEDULE "A" PART- X (LIFT) Details of prepriced Schedule is given in tender documents.
14SCHEDULE "A" PART- XI (RETAINING WALL) Details of prepriced Schedule is given in tender documents.
15SCHEDULE "A" PART- XII (FENCING AND STEEL GATE) Details of prepriced Schedule is given in tender documents.
16SCHEDULE "A" PART- XIII (LIGHTENINGPROTECTION) Details of prepriced Schedule is given in tender documents.
17SCHEDULE "A" PART- XIV (FIRE FIGHTING AND FIRE ALARM SYSTEM) Details of prepriced Schedule is given in tender documents.
18SCHEDULE "A" PART -XV (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col 5 signifies this fact only.
19S & F modular metal flush box with modular white cover plate with frame, 8 module complete all as specified and directed .
20S & F modular metal flush box with modular white cover plate with frame, 6 module complete all as specified and directed .
21S & F modular metal flush box with modular white cover plate with frame, 3 module complete all as specified and directed .
22S & F modular metal flush box with modular white cover plate with frame, 1 module complete all as specified and directed .
23S & FLED lamp 10 wattfixed to holder complete all as specified and directed.
24S&F modular TV coaxial cable socket with modular plate and switch box including connections including modular plate etc as required complete all as specified and directed.
25S&F modular Telephone socket with modular plate and switch box including connections including modular plate etc as required complete all as specified and directed.
26Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required complete all as specified and directed.
27Supplying and drawing Two pair 0.4 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required complete all as specified and directed.
28S&F LED light fittings 4 feet, 1 x 20 W, 220 V AC decorative box type with driver including LED tube light, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
29S&F LED light fittings with high output diffuser 2 feet, 1 x 10 W, 220 V AC decorative type with driver including LED lamp, connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
30S&F LED security light fittings, 1 x 35 watt with integral reflector made of aluminium alloy LM6 with LED driver including LED lamp, surge protector and all accessories, pre-wired, including bracket made of 40mm bore GI tubing, medium grade of 1.5m long, bent to shape with MS clamp, including connecting up with three core PVC insulated sheathed copper conductor cable of suitable size complete all as specified and directed.
31S & F LED lights fitting, 1x 9W/10W, bulkhead luminaires, 220V, AC LED lightwith driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
32S & F LED wall bracket decorative light fittings,1x 9W/10W, polycarbonate body including LED lightwith driver, holder and LED Bulb of B22 base andconnecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
33S & F modular type MCB protected socket box having metal flush box with PVC cover plate with one single pole MCB 20 Amps and one 20 Amp 3 pin power socket with 3 pin 20 Amp plug Top complete all as specified and as specified.
34S&F Exhaust fan, heavy duty, of size 300 mm sweep, metallic steel body, single phase, 900/950RPM, including suitable metallic louver, blades, frame and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete in all respect all as specified and directed.
35S&F Exhaust fan sturdy plastic body of size 300 mm sweep, metallic steel body, single phase, 1200RPM, heavy duty typ with suitable plastic louver, blades, frame and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete in all respect all as specified and directed.
36S&F electric water heater storage type steel body with stainless steel inner tank and heating element upto 1.5/2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, includingPVC connectionpipe for hot/ cold water to existing water lines,necessary fixing arrangementby using 50 X 5 mm MS plateand writing MES No and paste the instruction sheet of Do’s and DO NOTcomplete all as specified and as directed.
37S&F concealed sub main distribution box, double door, vertical type, TPN, 415V,12 way, IP 43 suitable for MCCB of 125 Amps, 4P, 16 kA as incomer and MCCB TP 40/63 Amp as outgoing complete with suitable bus bar, neutral link, earth link complete all as specified and directed. Note:(i) MCCB/MCBs shall be measured and paid separately (ii)Blank space shall be covered with blank plates and cost for the same shall be deemed to be included in the quoted rate.
38S&F concealed sub main distribution box, double door, vertical type, TPN, 415V,8 way, IP 43 suitable for MCCB of 100 Amps, 4P, 16 kA as incomer and MCCB TP 40/63 Amp as outgoing complete with suitable bus bar, neutral link, earth link complete all as specified and directed. Note:(i) MCCB/MCBs shall be measured and paid separately (ii)Blank space shall be covered with blank plates and cost for the same shall be deemed to be included in the quoted rate.
39S & F Smart RF/Cellelur/Hybrid (RF + Celluler) Three phase AC Meter Temper Proof, static meter of class 1.00, 415 V, 50 Hz, 10A-60A as per IS -16444 and relevant IEC standards with inbuilt Radio Frequency communication facility with self healing mesh network with default and no demand display, billing data generation facility, anti-temper features, Microprocessor and LED/LCD based circuitary including SMC meter box of minimum size 250 x 250 x 155mm or as suitable for 3 phase meter with viewing glass, concealed hinge and earth bolt plugged complete all as specified and as directed. Meter shall support sending the following data :- (i) 15/30 min instantaneous data for volgtage, current, power, cumulative energy and frequency, monthly billing survey for cumulative energy and max demand to software meter shall have connected/disconnected functionally operateable from mdm/billing software and prepaid features shall be MDM/Billing end as per prevalent IS. (Note:- Only meter shall be fixed in this scope of work and meter shall be confirming to IS-16444)
40Supply, Fixing and Installation of wall mounted Electric Kitchen Chimney of size 90cm, metal body,compact design suction 1250 m3/hr, Filter less and dry heat clean technology.matt black finish, hassle free and dry heat auto clean technology, thermostatic touch control panel with three speed gesture motion, black metal oil collector, motor with copper winding, black glass clad hood with LED insignia, front panel with black glass, energy saving MED light, metal blower plus metal housing, Noise level- 58 dBA (maximum), 5 years warranty complete with fixing system for smooth running of chimney complete all as specified and as directed.
41M&L for earthing complete with galvanized steel earth plate electrode 600 mm X 600 mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanised earth lead wire 4.0 mm dia bymeans of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plateNo-3 SSR Part -1 2009 connected to earthing test point including earth wire protection pipe of dia 15 mm (light grage), excavation and earth work, disposal of surplus spoil, provn of RCC cover 50 mm thick, reinforced with 8mm dia TMT bars @150 mm /C/C both ways with one handle for lifting made out of 10 mm dia TMT bar embedded in precast RCC (1:2:4) type B1, cover slab of size 54 cm x 54 cm x 5 cm and PCC (1:3:6) type C-1 concrete pit, funnel with watering pipe 20 mm bore (medium grade) testing on completion complete all as specified and directed. [Note : (a)Proper earthing pit should be provided with pit cover. (b) Excavation/earthwork is deemed to be included in the quoted rate.]
42S&F 15 mm bore angle cock, cast copper alloy, chromium plated with longshank and cup, fency type, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and directed.
43S&F 15 mm bore shower rose, cast copper alloy, chromoum plate with longshank and cup, fency type of length 300mm (minimum) complete all as specified and directed.
44M & L for LLDPE septic tankof capacity 5000 litres, with necessary strong basement with concrete as per manufacturer"s instructions , complete all as specified and as directed.(Note: Cost of basement including excavation in any type of soil , returning filling in and removal of surplus soil etc shall deemed to be included in the unit rate)
45Construction of Soakage well exc. In ordinary soil , foundation in PCC (1:3:6) type C2 (using 40mm graded stone aggregate), wells of honey combed masonry with top ring of RCC M-25 (design mix) using 20mm graded stone aggregate, including intercepting chamber, screen chamber made of brick work in CM 1:4, RCC cover slab in M-25 /SFRC cover, interconnecting pipes of RCC/DWC complete, filled with brick bats, size 1.2m dia x 3.0m deep (effective depth) complete all as specified and as shown on drawings.
46M & L for cement concrete (1:3:6) type C-2 (40 mmgraded broken aggregate) as in concrete bed to drain pipes for450 mm bore pipes including packing under and houching against the sides of pipes afterthey are laid and tested complete all as specified and as directed.
47M&L for construction of brick masonry valve pit chamber of internaldimension 900 x 900 x 900 mmdepth with sub class "B", old size, in CM (1:6) and 10mm thick plasteringin CM (1:4) ,PCC (1:4:8) type D2 (using 40mm graded broken stone aggregate ) as in foundation lean concrete ,PCC (1:3:6) type C1 (using 20mm graded broken stone aggregate) as in bedding and copping MS frame with 50x50x6mm angle iron 5mm thick MS sheet cover plate with locking system ,hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preperation of surface ,three coatsof whitewash on plastered suface (exposed to view ) including necessary excavation in soft loose ,soil ,returning filling in and removal of surplus soil to a distance not excedding 50 m complete all as specified and directed.
48Supply, installation, testing and commissioning of out door type LT cubical, self supported panel of size not less than 1200 x 900 x 500 mm with front door & rear openable with provision of locking arrangment, (one pad lock of 7 levers with three keys) , dust and vermin proof suitable for 3 phase, 4 wire system, 415 volt , made out 3.15 mm thick CRCA sheet covering on angle iron frame of size 50 x 50 x 6 mm incl canopy type roof10cm extended all sides, two parts hinged door in front side with locking and gasket arrangem ent, cubical type duly powder coated complete copper bus bar suitable for 150 Amp for phase and 400 Amps for nutral completefor housing, grouting on PCC foundation as per site requirements and as directed by Enginner-in-chargeand including the followings duly prewired wth suitable copper conducter cables:- (a) Incoming MCCB 4 pole 160 Amp 36 kA - 01 No. (b) Outgoing MCCB 4 pole 63 Amp 16 kA - 06 Nos. INDICATING DEVICE (i) LED indicating lamps for main supply and outgoing indicating "R, Y, B". (ii) 3 Phase Ammeter digital type with selector switch flush mounting square type with CT"s of suitable size. (iii)Volt meter 0-500 V digital with selector switch.(Incl PT) Note : (i) The contractor shall submit the test certificate from manufacturer. (ii) The contractor shall submitQAP (Quality assurance programme)within 15 days after placement of order for LT Panel testing at factory.LT Panel shall be dispatch only after inspection at manufacture premises to be done by OEM Auth & MES Auth at manufacture permisses. (iii) The contractorshall furnish origional bill certificate (Purchase voucher and test certificate) of the LT panel manufacturer. (iv) The contractor shall get the approval of GE for make of the LT panel boardbefore placing the order. (v) Prior to manufacturing the general arrangement drawing design details of the LT panel shall be get approved from GE. (vi) Connection of LT panel/starters/MCCBs through multi core copper conductor control cable of suitable size (irrespective of length) is deemed to be included in the item .
49Supply, installation, testing and commissioning of out door type LT cubical, self supported panel of size not less than 1200 x 900 x 500 mm with front door & rear openable with provision of locking arrangment, (one pad lock of 7 levers with three keys) , dust and vermin proof suitable for 3 phase, 4 wire system, 415 volt , made out 3.15 mm thick CRCA sheet covering on angle iron frame of size 50 x 50 x 6 mm incl canopy type roof10cm extended all sides, two parts hinged door in front side with locking and gasket arrangem ent, cubical type duly powder coated complete copper bus bar suitable for 150 Amp for phase and 400 Amps for nutral completefor housing, grouting on PCC foundation as per site requirements and as directed by Enginner-in-chargeand including the followings duly prewired wth suitable copper conducter cables:- (a) Incoming MCCB 4 pole 250Amp 36 kA - 01 No. (b) Outgoing MCCB 4 pole 160 Amp25 kA - 02 (W )Nos + 01(S) No INDICATING DEVICE (i) LED indicating lamps for main supply and outgoing indicating "R, Y, B". (ii) 3 Phase Ammeter digital type with selector switch flush mounting square type with CT"s of suitable size. (iii)Volt meter 0-500 V digital with selector switch.(Incl PT) Note : (i) The contractor shall submit the test certificate from manufacturer. (ii) The contractor shall submitQAP (Quality assurance programme)within 15 days after placement of order for LT Panel testing at factory.LT Panel shall be dispatch only after inspection at manufacture premises to be done by OEM Auth & MES Auth at manufacture permisses. (iii) The contractorshall furnish origional bill certificate (Purchase voucher and test certificate) of the LT panel manufacturer. (iv) The contractor shall get the approval of GE for make of the LT panel boardbefore placing the order. (v) Prior to manufacturing the general arrangement drawing design details of the LT panel shall be get approved from GE. (vi) Connection of LT panel/starters/MCCBs through multi core copper conductor control cable of suitable size (irrespective of length) is deemed to be included in the item .
50Supply and installation, testing and commissioning of copper wound transformer step down, outdoor type, complete with standard fittings, HT11 KV,3 Phase, LT 433 volts, 3 Phase + 1 Neutral, 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as per IS:1180 (Part I), level 2 (as per latest edision/amendment), 3 Phase, & 50Hz, Type of cooling ONAN,off circuit Tap switch changer, including all connected accessories as per standadrd schedule of capacity 160 KVA, top up/first filling of oil and testing as per standard practice all as specified and directed. Specification of Transformer :- (a) Cooling type - ONAN oil cooled as per IS 335, BS 148, D 1473, IEC Pub 296. (b) Winding - Copper wound as per ASTM B-49. (c) Air clearance - Minimum air clearance for HV-HV and LV-LV as per IS 1180 or latest. (d) Vector group - DYN-11. (e) Flux density - Should not be more than 1.55 Tesla (f) Star rate - 2 star rated and labelled on the body with colour code, logo etc as per BEE standard. (g) Transformer tank shall be constructed robust rectangular shape with wall thickness not less than MS plate supported with adequate Angle iron at all corners, joints etc with healthy fabrication method, painted inside with weather proof oil resistance paint, external body painted with weather proof paint after applying healthy zinc chromite primer. Colour shall be get approved by GE. (h) Radiators - Press fin type (j) Pressure Release Device shall be provided with operating pressure before 0.25 Kg/Sqcm (k) HT/LT bushings shall confirm IS 3347 with standard make
51Serial Item No. 15.32 (Contd....) (l) HT/LT spindles shall be made up of brass and fitted properly on their respective terminals. (m) Silica gel with breather shall be placed at the place where moisture ingress can be avoided to maximum and it must be mentioned in the drawing during approval stage. (n) Oil level guage, Temp guage and pressure guage shall be provided where indicated as per approved drawing. NOTE :- (Item No. 13.24 contd..) (a) All the arrangements for loading unloading and placement on platform shall be made by the contractor. (b) The contractor/manufacturer shall furnish original certificate (paid voucher and test certificate) of the CRGO manufacturer. (c) The manufacturer /contractor shall furnish the diameter of LV and HV copper winding and its total resistance. The stray losses shall be specified in percentage terms. (d) The contractor shall get the approval of GE for the make of the transformer they plan to procure. (e) Prior to manufacturing the general arrangement drawing design details of the transformer shall be got approved by GE. (f) Transformer shall be dispatch only after inspection clearance by inspecting officer detailed bu Accepting Officer. (g) Testing of transformer at various load factors shall be done at site with the help of OEM technician till achieving satisfactory result at site in front of Engineer-in-Charge. (h) All the HT/LT UG cables shall be properly connected it at their respective terminals without any any contact before testing.
52Serial Item No. 15.32 & 15.33(Contd....) (j) Transformer shall be provided with robust lifting hook so that it can be easily lifted for transportation and shifting. (k) Transformer shall be mounted on channel and wheel with stopper pin so it can be moved easily. (l) Necessary foundation with plinth shall be provided as per manufacturer"s recommendation, quoted rate shall be deemed to be included accordingly.
53Supply ,install & commissioning of Ring main unit (one incoming +02 outgoing) (01 LBS +02 VCB) 3 Way , Non extendible outdoor type of rating 630 A Aluminium busbar with a fault clearing capacity of 21 KA for 3 Sec,rated voltage 12 KV,operational voltage-11 KV,frequency - 50 HZ,totally enclosed Ring Main unit with IP 67 protection for SF6 tank and IP 55 protection for outdoor enclosure with self powered microprocessor based numerical relay with over current and earth fault protection,should be tested for internal arc test of 21 KA for 1 sec as per IEC 62271-200 Standards complete all as specified and as directed.
54Supply, layingin trenchessub class "B" bricks locally available of 230 x 115 x 75mmfor cable protectioncomplete all as specified and directed.
55M&L for Earthing complete with copperearth plate electrode of size 600 x 600 x 3.15 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to 20×3mm copper stripas earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel,protected by galvanized iron pipe 40mm bore (Medium grade) allas directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel,wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed.( Copper stripupto 7.5m including testing consider in this item). [Note : (a)Proper earthing pit should be provided with pit cover. (b)The unit rate includes for protection pipe and earth strip upto 7.5 m. Any variation in length of earth lead and protection pipe beyond 7.5 m shall be measured and paid seperately. (c) Excavation/earthwork is deemed to be included in the quoted rate.]
56Cutting, screwing without taking down existing DI water tubing of size 150 mm bore, for addition/alteration complete all as specified and directed.
57S&F for ductile iron pipes fittings both flanged & socket type (socket,bend, nipple,Y & tail piece flange etc) and including all jointing mateials of pipes of size upto 150mm complete all as specified and directed.
58Supplying, installation of silent Diesel Engine Driven generating set 415 volt, 3 phase 4 wire 0.8 PF,engine as per IS 10001/10002 and alternator as per IS 13364 complete with relay panel and switch gears for Automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms and foundation of capacity 30 KVA Comprising and including of following:- (A)DIESEL ENGINE: Liquid cooled turbo charged with after cooler to deliver suitable BHP at 1500RPM under NTP conditions of BS 5514 and conforming to IS 10002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation. Diesel engine of rated speed at full load electric start developingwithsystem with radiator and including electronic governor control of class A1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries ofadequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete with following:- (a) Radiator with blower fan or heat exchangar with guard. (b) Pipe coupling for engine cooling system piping. (c ) Corrosion inhibitor coolant (d) Paper element filters (i) Fuel filter (ii) Lube oil filter complete with first filling of lub oil (iii) Bypass filter (e) Fly wheel housing and fly wheel to suit alternator. (f) Engine bearing mechanism in fly wheel housing. (g) Shut off coil with safeties for LLOP/HWT/over speed. (h) Dry type replaceable air cleaners and vacuum indicators. (j) Residential silencers.
59Serial Item No. 15.40 (Contd....) (k) Stainless steel exhaust flexible bellows. (l) Motor driven priming pump. (m) Battery charging alternator. (n) Exhaust piping made out of STIC "C" class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturer"s recommendations to sustain back pressure with rain cap. (o) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet 30 gauge for the entire length of exhaust pipe. (p) First fill of oil, coolant and diesel during commissioning and 12 hours testing. (q) Interconnecting copper cabling of adequate capacity batteries control. (r ) Fuel pipe class (s) Self starter (t) Electric operated electronic governor. (u) Fuel injection pump. (v) Electronic instrument panel, complete with all accessories as per manufacturer"s specifications displaying the following:- (i) Battery as per manufacturer recommendation. (ii) Water temperature. (iii) lubricating oil pressure. (iv) Engine speed -1500 RPM (v) Engine hours (vi) Frequency. (vii) Voltage. (viii) Safety control (Trip and indication). (ix) High water temperature (x) Low lube oil temperature& (xi) Overspeed stop
60Serial Item No. 15.40 & 15.41 (Contd....) (B) ALTERNATOR - Brushless AC alternator, 3 Phase, 415 Volt, 4 wire, rated for output of 25 KVA ,minimum power factory 0.8, 1500 RPM , insulation class "H" salient pole, revolving field, single bearing automatic voltage regulator and directly coupled with engine. (C) ENGINE INSTRUMENT PANEL- (i) Digital type controller able to display- alternator voltage, battery voltage, load current, fuel level, lub oil pressure, frequency, RPM and able to stop generator on any fault and to display parameters i.e. low battery,LLOP, under voltage, over voltage, High engine temperature and other protection as per manufacturer recommendations including necessary wiring set of relayss, MCB/Fuse etc complete. (ii) Engine start and stop switch (iii) Emergency Stop Switch (iv) DC power supply suitable for controller. (D) AMF CONTROL PANEL: Supply Installation, testing andcommissioningof factory made, outdoor type, double door, floor mounted, cubical auto mains failure panel suitable for 25 KVA DG set, fabricated using 3.15 mm thick CRCA sheet, powder coated/ painted, including suitable rating bus bar, prewired including provn of connecting incoming & outgoing bus bas, including able to display Alternator Voltage/ Mains Voltage, Frequency, Load current, Battery voltage, PF, DG Set fails to start, including selector switch, Auto/Manual/reset Selector switch as approved with necessary foundation and including the following accessories as under:- (a) Set of relays and contactors/ATS 4 pole, 415 volt, 100 Amps for automatic connecting & disconnecting of load -1 Set (b) MCCB 4 pole 415 Volts with mocroprocessor controller of breaking capacity 25 KA, 100 Amps adjustable setting type -3 Nos (Two Nos for Incoming & One No for Outgoing).
61Serial Item No. 15.40, 15.41 &15.42 (Contd....) (c)Suitable battery charger connected to load side to charger battery including connecting leads. (Note: AMF Panel shall be installed out side the acoustic enclosure). (E) BASE PLATE: Common fabricated base frame for engine & alternator made from structural Steel channel, jerk proof on PCC 1:2:4 type B1 foundation including adequate number of anti-vibration pads in adequate quantity all as per the recommendation of the manufacturer. (Note:- Cost of suitable size of PCC foundation is deemed to be included in the unit rate quoted by the contractor). (F) DIESEL STORAGE TANK: Fuel tank of MS sheet of capacity not less than 12 Hrs continuous operation on full load with fuel level guage, drain plug, locking arrengements, etc including connection to Engine through fuel filter/ manual feed pump as per manufacturer recommendation. (G) ACOUSTIC ENCLOSURE: Sheet metal fabricatedcope type silent enclosure manufactured on CNC machines as per CPCB norms and power coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75 % load under field condition and70DB at 3 M from Gen set when DG set is working at full load along with testing conformance, laveling certification etc as laid down in GSR No.371(E) dt 17 May 2002 or latest. (H) MISC: Tool kit operation, maint cat, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturers standard practice. (j)PCC foundation of size 60 cm projection on both sides from the actual size of DG set and height of 1.20 mtr above ground level and 0.75mm below ground shall deemed to be included on the quoted rate.(k) Adequate diesel and load bank for 12 Hrs fall load testing shall be provided by the contractor during testing and commissioning of DG Set.
62Demolition of un-reinforced cement concrete of any description and in any position not otherwise specifically provided for and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 m, complete all as specified and directed.
63Demolition of brickwork or stone/boulder masonary, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, etc. all as directed.
64S&F portable type fire extinguisher of 9 Kg , cylindrical in shape, foam type fixed inside the lift and exit way staircase wall and entrance door of each quarter including complete mounting accessories complete all as specified and as directed.
65S & F Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard for keeping 2 Nos hose pipe of length 15 meter each, branch pipe.nozzle, coupling etc complete all as specified and as directed (Note : Nozzle head should be made up of brass metal heavy grade as per IS grad. Hose box needs to be provided with lock and key facilities
66S & F electric motor siren conforming to IS-1941 suitable for three phase 415V with motor not exceeding 3.75 KW power andable to deliver 143 dB noice level complete all as specified and as directed.
67S&F emergency exit display board of size 30cm x 10cm, at exit point of each floor made up of acrlylic cover with pre-wired LED lights for illumination at night complete all as specified and as directed. Note: (i) Writing letters shall be displayed in red colour. (ii) Concealed type Point wiring shall be provided with switch control by taping from nearest junction box or nearest point by the contractor.
68NOTE: Schedule of cedit (Sch "A" Part- XVI) amount of Rs 41,250.00 shall be deducted from the total quoted amount of BOQ.