}

Tender For Periodical Services And Repair To Rcc Chajjas Facia Columns Beams And Connected Items To Internal/External Surfaces Of Bldgs In C2a And C2b Area Under Ge (East) Mathura, mathura-Uttar Pradesh

Military Engineer Services-MES has published Tender For Periodical Services And Repair To Rcc Chajjas Facia Columns Beams And Connected Items To Internal/External Surfaces Of Bldgs In C2a And C2b Area Under Ge (East) Mathura. Submission Date for this Tender is 04-05-2024. Shed Construction Tenders in mathura Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43159659
Corrigendum : Tender For Periodical Services And Repair To Rcc Chajjas Facia Columns Beams And Connected Items To Internal/External Surfaces Of Bldgs In C2a And C2b Area Under Ge (East) Mathura
Open Tender
Indian
Uttar Pradesh
mathura
04-05-2024

Tender Details

Tender For Periodical Services And Repair To Rcc Chajjas Facia Columns Beams And Connected Items To Internal/External Surfaces Of Bldgs In C2a And C2b Area Under Ge (East) Mathura

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Apr-2024 AMENDMENT BOQ 04-05-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 100000.0 /-
Tender Value
INR 50 Lakhs /-

BOQ Items

Name of Work:PERIODICAL SERVICES AND REPAIRS TO RCC CHAJJAS FACIA COLUMNS BEAM AND CONNECTED ITEMS TO INTERNAL/EXTERNAL SURFACES OF BLDGS IN AT C2A AND C2B AREA UNDER GE(EAST) MATHURA.
Sl. No. Item Description
1Taking down Cement plaster from brick walls or concrete surface etc incl raking out joints, hacking for key and scrubbing down with water etc all as specified and as directed.
2M&L rendering 15mm thick on fair face of brick walls or concrete surface in cement mortar 1:4 mixed with liquid WPC as per manufactures Instructions and finishing surface even & fair complete all as specified and as directed. Note :- Liquid WPC shall be measured & paid seprately under relevant item of this BOQ.
3M&L rendering 15mm thick on other than fair faces of brick walls or concrete surface in cement mortar 1:6 and finishing surface even & smooth without using extra cement complete all as specified and as directed.
4M&L for rendering 10mm thick on fair faces of brick or concrete surfaces in cement mortar 1:6 and finishing the surface even & fair complete all as specified and as directed.
5M&L for rendering 10 mm thick on fair faces of bricks or concrete surfaces as in ceiling surfaces in cement mortar 1:3 finished even & fair all as specified and as directed.
6Supply only liquid water proofing compound complete all as specified and as directed.
7Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work (reinforecement cut as required to facilitate demolition) complete all as specified and as directed.
8M&L for 50mm thick sand stone slab as in chajja/cover slab set and jointed over supports in cement mortar 1:4 complete all as specified and as directed.
9M&L for Cutting grooves in brick wall, 75mm wide and 65mm deep for fixing joist,angle, channel section and sandstone slab in chajjas upto G+2 floors and finishing face of groove with cement mortar 1:3 complete all as specified and as directed.
10S&F rolled mild steel joist, channel, angle or Tee section fixed independently without connecting plate etc cut to ordinary length i.e. within 20 mm of length indicated) of Fe 410 Gde E-250 quality including applying two coat of synthetic enamel paint over a coat of primer complete all as specified and as directed.
11M&L for providing damp proof layer in two coats of acrylic polymer coating consisting of 1 part of acrylic polymer liquid mixed with 2 parts of cementious powder applying at the rate of 1.40 Sqm/ Kg of mix per coat. Second coat should be applied after 4-6 hrs of first coat, 5 days curing is to be carried out to the surface before providing plastering. Note : Make of the material "Smart Care damp block 2K" of Asian paints or equivalent from Dr Fixit/STP/CICA as approved by GE.
12M&L for repairing the edges/corner of Chajja/roof projection and similar work by removing plaster width/girth not exceeding 150 mm and making good with 10 mm thick rendering in cement mortar 1:3 to match with existing surface complete allas specified and as directed.
13Demolition of brick work or stone boulder masonary built in cement mortar including all quoins arches pillars etc. but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and as directed.
14M&L for Brickwork using fly ash old size bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed.
15M&L for cement concrete type C2 1:3:6 (using 40 mm graded stone aggregates) as in foundation, filling and mass concrete complete all as specified and as directed.
16M&L for MS TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
17All as per item serial No 16.00 here-in-before but MS round bar 10 mm dia and over as in handles of manhole covers complete all as specified and as directed.
18M&L for pre cast reinforced cement concrete type B-1 1:2:4 (using 20 mm graded stone aggregate) as in cover slab for manholes, chajja, shelves and similar articles including form work etc complete all as specified and as directed. Note : Reinforcement shall be measured and paid separtely under relevant item(s) of this BOQ.
19M&L for Reinforced cement concrete type B-1 1:2:4 (using 12.50 mm graded stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. Note : Reinforcement shall be measured and paid separtely under relevant item(s) of this BOQ.
20M&L for providing precast cement concrete type B0 1:2:4 (using 12.5 mm graded stone aggregate) as in louvers and jallies 40mm thick including all mouldings set in cement mortar 1:4 complete all as specified and as directed.
21M&L for Providing, cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in coping, kerbs, benching etc complete all specified and as directed.
22M&L for removal of plants with roots from roof/wall/shafts any size and height and applying HCL chemical and filling hole with cement concrete 1:2:4 minimum 0.05 cum in each location and finished properly to matched with the surrounding area complete all as specified and as directed.
23Taking up or down 15 mm bore steel tubing and connections including cleaning for refixing complete all as specified and as directed.
24Supplying & fixing steel tubing ,galvanised, medium grade 15 mm bore with all fittings and fixed complete to walls and ceiling or laid under floor complete all as specified and as directed.
25Taking up or down 20 mm bore steel tubing and connections including cleaning for refixing complete all as specified and as directed.
26Supplying & fixing steel tubing ,galvanised, medium grade 20 mm bore with all fittings and fixed complete to walls and ceiling or laid under floor complete all as specified and as directed.
27S&F in repair rotational moulded polyethylene water storage tank (Triple layers white in colour) (Cylindrical vertical with close top) 1000 liters capacity having monkey protection cover hoisted and fixed in position on roof including connections complete all as specified and as directed.
28S&F in repair rotational moulded polyethylene water storage tank (Triple layers white in colour) (Cylindrical vertical with close top) 500 liters capacity having monkey protection cover hoisted and fixed in position on roof including connections complete all as specified and as directed.
29S&F Ball brass valve high pressure with polythene float and fly nuts complete screwed for 20 mm bore dia iron pipes or brass ferrule and fixed complete all as specified and as directed.
30S&F in repair Ball brass valve high pressure with polythene float and fly nuts complete screwed for 20 mm bore dia iron pipes or brass ferrule and fixed complete all as specified and as directed.
31S&F in repairs monkey protection cover for HDPE water tank of capacity 500/750/1000 ltrs rotating type with frame including nut boltcomplete all as specified and as directed.
32S&F in repair 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with MS clamps complete all as specified and as directed.
33S&F in repair 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls with MS clamps complete all as specified and as directed.
34S&F in repair 110 mm bore PVC (SWR) bends any radius provided with access door complete all as specified and as directed.
35S&F in repair 75 mm bore PVC (SWR) bends any radius complete all as specified and as directed.
36M&L for chipping of unsound/deteriorated cement concrete up to 50mm average thickness from slabs, beams, columns, chhajjas etc with manual chisel including tempering of all edges including cleaning of exposed concrete surfaces and reinforcement with wire brushes etc and disposal of debris complete all as specified and as directed.
37M&L for Identifying and marking carefully the damaged reinforced concrete by tapping with light hammer and chipping of unsound weak concrete and plaster material from slabs/beams/columns etc. with power/hand driven chisel as directed by the engineer-in-charge upto 40 mm average depth including saw-cutting of all edges making square shoulders of the cavities all as specified and as directed. Note :- (i) All loose unsound and cracked concrete shall be removed out side MD land. (ii) Thickness will be measured excluding plaster
38M&L for providing mixing and applying over reinforcement bars zinc antirust agent as per specification of make "Fosroc Nitozinc Primer STD base" or equivalent in SIKA/Thermax/FOSROC complete all as specified and as directed.
39Mixing and applying SBR latex modified cement mortar 25 mm thick in cement sand mortar in proportions of 1:3 (1 cement and 2 graded quartz aggregate) with polymer admixed in proportions as approved, including trowelling with wooden tools on prepared concrete surfaces of parent material complete all as specified and as directed. Note :- Acrylic polymer will be paid for separately.
40Supply only approved SBR latex from FOSROC/BASF/DR FIXIT/ SIKA for bonding coat/Polymer modified cement mortor complete all as specified and as directed. Note: Rate shall be in terms of solid contents of polymer.
41M&L for preparation of newly plastered surfaces of walls/ceilings and applying two coats of weather proof acrylic exterior paint dark shade over a coat of primer (100% Acrylic) using spray machine, spray hard to receive area to achieve excellent application using limited manpowerincluding scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed.
42M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint white or tinted over and including a coat of primer complete all as specified and as directed.
43M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed.
44M&L for preparation of old plastered surface of walls and applying onecoats of white wash complete all as specified and as directed.
45M&L for preparation of old plastered surface of ceiling and applying onecoats of white wash complete all as specified and as directed.
46M&L for Providing 1mm thick wall care putty on surfaces of walls complete all as specified and as directed.
47M&L for preparation of old decorative surfaces of walls and applying one coat of oil bound distemper complete all as specified and as directed.
48M&L for complete removal of existing treatment from old plastered surfaces of walls and applying two coats of distemper oil emulsion paint complete all as specified and as directed.
49M&L for preperation of old plastered surfaces of walls/ceilings and applying one coats of weather proof acrylic exterior paint including required scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed.
50M&L for preperation of old plastered surfaces of walls/ceilings and applying one coats of cement base paint including required scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed.
51M&L for complete removal of existing treatment from old plastered surfaces of walls and applying two coats of cement base paint including required scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed.
52M&L for preparation of old painted wooden surfaces of any description not otherwise described over 10cm width or girthand applying one coat of synthetic enamel paint complete all as specified and as directed.
53M&L for preparation of old painted steel surface of any description not otherwise described over 10 cm in width or girth and applying one coat of synthetic enamel paint all as specified and as directed
54M&L for preparation of old painted Concrete surface of any description not otherwise described over 10 cm in width or girth and applying one coat of synthetic enamel paint all as specified and as directed.
55M&L for french polishing two or more coat on old wood and wood based surfaces of any description, width or girth including cleaning, and preparing the surface complete all as specified and as directed.
56M&L Obliterating old writing of any description with synthetic enamel paint n.exc 0.10 sqm each to match the existing work complete all as specified and as directed.
57M&L for Writing letters or figures (Block, Roman, Italic or Indian) n.exc 30 Cm high complete all as specified and as directed.
58Demolition of cement concrete (unreinforced) in ground floors or other than ground floor and pavings n exc 15cm thickness below or above ground level complete all as specified and as directed.
59M&L for 50 mm thick cement concrete type C-1 1:3:6 (using 20 mm graded stone aggregate) as in plinth protection, finishing cement concrete surface even and smooth (without using extra cement) compete all as specified and as directed.
60M&L for 75mm cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in alternate bays and joints filled with bitument and sand mixed in 1:3 finished surface even and fair with using extra cement complete all as specified and as directed.
61M&L non skid colouredcermic ENDURA tiles exc 0.06 Sqm but n. exc. 0.11 Sqm10 mm thickset and jointed in neat cement slurry & pointed with coloured cement to match in floor laid over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and as directed.
62M&L for Chequered cement concrete tiles with white cement and pigment 20cm x 20cm x 25mm thick rubber moulded glossey finish, set, jointed and pointed in neat cement slurry in floors over and including 20mm screed bedding in cement mortar 1:6 complete all as specified and as directed.
63M&L machine pressed precast concrete interlocking paver block with gray cement and pigment of any shape and size conforming to IS 15658-2006 of80mm thickness M-40grade of concrete as in floors/pavements complete all as specified and as directed.
64M&L 100mm thick cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in sub base complete all as specified and as directed.
65M&L for layer of sand cushioning 25 mm thick over cement concrete base complete all as specified and as directed.
66M&L for cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in coping surface channels, benchings, manholes finished even and fair complete all as specified and as directed.
67S&F in repair Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with stainless steel wire staples complete all as specified and as directed.
68S&F 4mmthick sheet glass ordinary quality and glazing with oil putty/wooden/rubber beadingin Sqm n.exc 0.50 Sqm in each pane complete all as specified and as directed.
69S&F 4mmthick sheet glass ordinary quality and glazing with oil putty/wooden/rubber beadingin Sqm exc 0.50 Sqm in each pane complete all as specified and as directed.
70S&Fin repairs 25 mm dia stainless steel alloy tubular drapery rod cut to size and fixed in position including fixing brackets, stops, rollers end caps etc. complete all as specified and as directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail