| 1 | Supply of following sizes of 1100V rated, Cu conductor, XLPE insulated, FRLS PVC (ST2) inner and outer sheathed power cables along with steel/wooden cable drums |
| 2 | 1Cx800 sqmm armoured cable (Al armour) along with steel drum |
| 3 | 3.5Cx300 sqmm armoured cable (GI armour) along with steel drum |
| 4 | 3Cx2.5 sqmm un-armoured cable along with wooden cable drum |
| 5 | Supply of following sizes of 1100V rated, Cu conductor, PVC (Type-A) insulated, Overall screened, FRLS PVC (ST1) inner and outer sheathed, GI armoured control cables along with wooden cable drums |
| 6 | 4Cx2.5 sqmm |
| 7 | 2Cx2.5 sqmm |
| 8 | Supply of following medium duty GI pipes/ heavy duty ERW Rigid Conduits for routing cables from cable trays to Distribution Boards or to various field equipment or between equipment as directed by Engineer- in- charge. |
| 9 | 25 mm Dia Conduit |
| 10 | Installation of following medium duty GI pipes/ Conduits for routing cables (from cable trays to Distribution Boards or to various field equipment or between equipment as directed by Engineer- in- charge), including supply and installation of clamps/ fasteners/ supports, accessories like bends/ couplers along with cutting, threading etc. |
| 11 | 25 mm Dia Conduit |
| 12 | Laying and dressing of following types of power cables in cable trays & conduits/GI pipes in building, buried in soil, through hume pipes including supply & installation of cable binding wires, cable dressing wires, hardware for clamping/ fixing, sand, burnt bricks, cable route marker etc., as specified. It also includes excavation of soil for buried cable route, clearing of obstructions, laying of hume pipes, cutting of roads and re-construction of roads as per original etc. |
| 13 | 3Cx2.5, Cu, Unarmoured - Laid in Cable Tray/ Rigid Conduit |
| 14 | 1Cx800, Cu, Armoured – Buried in soil |
| 15 | 3.5Cx300, Cu, Armoured – Buried in soil |
| 16 | Laying and dressing of OFC cable in cable trays & conduits/GI pipes in building, buried in soil, through hume pipes including supply & installation of cable binding wires, cable dressing wires, hardware for clamping/ fixing, sand, burnt bricks, cable route marker etc., as specified. It also includes excavation of soil for buried cable route, clearing of obstructions, laying of hume pipes, cutting of roads and re-construction of roads as per original etc. |
| 17 | Armoured fiber optic cable |
| 18 | Laying and dressing of following types of control cables in conduits in building including supply & installation of cable binding wires, cable dressing wires, hardware for clamping/ fixing etc., as specified. |
| 19 | 4Cx2.5, Cu, Armoured - Laid in Conduit |
| 20 | 2Cx2.5, Cu, Armoured - Laid in Conduit |
| 21 | Supply of cable glands for the following power cables |
| 22 | 3Cx2.5, Cu, Unarm |
| 23 | 1Cx800, Cu, Armoured |
| 24 | 3.5Cx300, Cu, Armoured |
| 25 | Supply of cable glands for the following control cables |
| 26 | 4Cx2.5, Cu, Armoured |
| 27 | 2Cx2.5, Cu, Armoured |
| 28 | Supply of lugs for the following power cables |
| 29 | 3Cx2.5, Cu, Unarm |
| 30 | 1Cx800, Cu, Armoured |
| 31 | 3.5Cx300, Cu, Armoured |
| 32 | Supply of lugs for the following control cables |
| 33 | 4Cx2.5, Cu, Armoured |
| 34 | 2Cx2.5, Cu, Armoured |
| 35 | Termination/ connection of following types and sizes of power cables at both ends along with cable glands, lugs, ferrules, clamps, hardware etc., and drilling of gland plates, crimping of lugs for termination of following cables (Source end & load end considered separately) |
| 36 | 3Cx2.5, Cu, Unarm |
| 37 | 1Cx800, Cu, Armoured |
| 38 | 3.5Cx300, Cu, Armoured |
| 39 | Termination/ connection of following types and sizes of control cables at both ends along with cable glands, lugs, ferrules, clamps, hardware etc., and drilling of gland plates, crimping of lugs for termination of following cables (Source end & load end considered separately) |
| 40 | 4Cx2.5, Cu, Armoured |
| 41 | 2Cx2.5, Cu, Armoured |
| 42 | Supply of 400A, 4 Pole Switch Fuse Unit. SFU output terminal shall be suitable for connection of 2 runs of 3.5Cx 300 sqmm Cu conductor |
| 43 | Removal of existing switching and protection device in existing transformer distribution panel in transformer yard behind Simulator building of KAPS-1&2 and handing it to Purchaser for depositing it in his O&M stores. Installation & mounting of 400A, 4 Pole Switch Fuse Unit in place of removed switching and protection device and connection of it to OESC power supply incomer feeder. |
| 44 | Supply of 0.63A-1A, 3 Pole MPCB |
| 45 | Installation of 0.63A-1A, 3 pole MPCB on the wall near to each exhaust and propeller fans and connecting the same to exhaust/ propeller fan power supply cable along with supply and installation of all necessary mounting hardware |
| 46 | Supply of 2 channel unidirectional/ 1 channel bi-directional dry contact closure fiber optic converters (transmitter and receiver) for conversion of electromagnetic relay contact to optical signal for transmission through existing fiber optic cable along with necessary cabling/ power adapter for connection to nearest power supply source to feed auxiliary power supply to the converter. |
| 47 | Installation & mounting of 2 channel unidirectional/ 1 channel bi-directional dry contact closure fiber optic converters (transmitter and receiver) in existing SAPMS panel and connection of its power adapter/ auxiliary power wiring to nearest power source. Connection of the output and input terminals of these converters to control cable from electromagnetic relay contact and also to existing fiber optic cable spare core is included in installation scope. Supply and installation of all accessory required for complete connection, integration and successful transfer through existing fiber optic cable and reading of electromagnetic relay contact status at other end, along with configuration, setting of converter is included in this installation part. Testing and commission of the complete system after connection of site end cable to MCR WAN is also included in the scope of this installation. |
| 48 | Supply of following sizes of GI conduit, as specified |
| 49 | 25 mm dia GI conduit |
| 50 | Installation of following sizes of GI conduits including supply & installation of all accessories like bends, elbows, couplers, hospital saddles, spacers, GI Junction boxes, GI pull boxes, etc., and other accessories required to complete the job on wall/ column/ ceiling etc. as per specification and drawings. (The running length shall be measured along the center line including bends, fittings etc. along the run installed, but excluding the hidden length of conduits and lengths of pull boxes and junction boxes) |
| 51 | 25 mm dia GI conduit |
| 52 | Supply of following sizes of wires as detailed in this specification |
| 53 | 4 sq.mm. copper wire |
| 54 | 6 sq.mm. copper wire |
| 55 | Installation/ termination/ connection of following sizes of wires as specified |
| 56 | 4 sq.mm. copper wire |
| 57 | 6 sq.mm. copper wire |
| 58 | Supply of 14 SWG stranded copper grounding wire as detailed in this specification |
| 59 | Installation/ termination/ connection of 14 SWG stranded copper grounding wire including supply and installation of clamps, connection to earthing terminals, lighting fixtures, Junction boxes, pull boxes etc., as detailed in the specification and drawings. |
| 60 | Supply of following types of junction boxes/ pull boxes for Lighting & receptacle |
| 61 | JB for lighting and 1 phase receptacle |
| 62 | Pull boxes for lighting and 1 phase receptacle |
| 63 | Installation of following types of junction boxes/ pull boxes for Lighting & receptacle including supply and installation of anchor fasteners, mounting brackets, support structure, hardware etc. (wherever required) along with necessary welding, drilling, painting etc. |
| 64 | JB for lighting and 1 phase receptacle |
| 65 | Pull boxes for lighting and 1 phase receptacle |
| 66 | Supply of Outdoor compound lighting photo-voltaic cell control panel including photo cell & its timer as per specification and drawing |
| 67 | Installation of Outdoor compound lighting photo-voltaic cell control panel (including photo cell & its timer) including supply and installation of seismically qualified anchor fasteners, mounting brackets, support structure, hardware etc. along with necessary welding, drilling, painting, bolting etc. |
| 68 | Supply of Outdoor compound lighting fixture (SL1 type) as per specification requirement |
| 69 | Installation of following types of lighting fixtures including supply and installation of GI rigid & flexible conduits, suitable size of wires between nearest JBs and fixture terminals, mounting hardware, structural steel swan neck pipe, clamping/ fixing hardware etc. required for mounting the fittings, seismically qualified anchor fasteners, mounting brackets, support structure, plates, hardware etc. (as required) along with necessary welding, drilling, painting etc. Fixture mounting hardware, anchor fasteners and structural steel members shall be as per qualified fixture supports and the qualified fixture support details will be shared with successful Bidder. |
| 70 | Surface mounting (Wall/ Column/ Floor slab soffit/ beam soffit) of Equivalent Type B LED fixture |
| 71 | Type-VB mounting of Equivalent Type SL1 LED fixture |
| 72 | Supply of copper / GS earthing leads of following sizes |
| 73 | 65.09 sq. mm. Cu |
| 74 | 35 sq. mm. Cu |
| 75 | 10 sq. mm. Cu |
| 76 | Supply of following sizes of crimpable copper lugs |
| 77 | 65.09 sq.mm. |
| 78 | 35 sq.mm. |
| 79 | 10 sq.mm. |
| 80 | Supply of following sizes of copper offset bar lugs |
| 81 | 65.09 sq.mm. |
| 82 | Installation of copper/GS earthing leads of following sizes for connecting equipment earthing terminal to nearest earthing pads including crimping/ brazing of copper conductor to lug, bolting/ brazing of conductor/ lug to equipment/ earthing pad, clamping over conduits using copper earth clips, making chase in the floor, grouting the chased area of the floor, hardware, bi-metallic connector etc., as required shall be supplied and installed |
| 83 | 65.09 sq. mm. Cu |
| 84 | 35 sq. mm. Cu |
| 85 | 10 sq. mm. Cu |
| 86 | Installation of following sizes of crimpable copper lugs |
| 87 | 65.09 sq.mm. |
| 88 | 35 sq.mm. |
| 89 | 10 sq.mm. |
| 90 | Installation of following sizes of copper offset bar lugs |
| 91 | 65.09 sq.mm. |
| 92 | Supply of Class-A Insulating Mat as per IS-15652 for complete front and back side of ADG set, ACDBs, UPS and Battery bank |
| 93 | Installation of Class-A Insulating Mat for complete front and back side of ADG set, ACDBs, UPS and Battery bank |
| 94 | Supply of Danger Notice Plate as per IS-2551 for all LV panels wherever they are not provided |
| 95 | Installation of Danger Notice Plate as per IS-2551 for all LV panels wherever they are not provided |
| 96 | Supply of required pre-fabricated galvanized/ painted structural steel members for supporting of equipment/ components wherever the requirement is there |
| 97 | Installation of the above pre-fabricatedgalvanized/ painted structural steel members for supporting of equipment/ components including all necessary works like cutting, drilling, painting, fabrication, welding, bolting, all hardware for fixing etc. |
| 98 | Supply of following sizes of seismically qualified under-cut anchor fasteners of reputed make like M/s Hilti/ Fischer with anchor length suitable for fixing any thickness of plate commensurate with required equipment loading: |
| 99 | M12 anchor bolts |
| 100 | M16 anchor bolts |
| 101 | M20 anchor bolts |
| 102 | M24 anchor bolts |
| 103 | Installation of following sizes of seismically qualified under-cut anchor fasteners with anchor length suitable for fixing any thickness of plate commensurate with required equipment loading including work like drilling, cleaning, tightening etc. |
| 104 | M12 anchor bolts |
| 105 | M16 anchor bolts |
| 106 | M20 anchor bolts |
| 107 | M24 anchor bolts |
| 108 | Supply of Junction Box with suitable copper bus bar for termination of 1Cx800 sqmm incomer cables as per speci-fication |
| 109 | Installation of Junction Box including supply and installation of seismically qualified anchor fasteners, mounting brackets, support structure, hardware etc. along with necessary welding, drilling, painting, bolting etc. |