| 1 | Shed with roofing at Ethanol Decantation point |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides & ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil & disposal of surplus excavated soil as directed within or outside the site at an unobjectionable place.i) All kinds of Soil |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m |
| 4 | Providing & laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc. UP TO FLOOR V LEVEL excluding the cost of centering, shuttering and finishing : |
| 5 | i) PCC 1 Cement:1 Coarse Sand:2 Graded Stone Aggregate 20mm |
| 6 | Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in: |
| 7 | ii) 1 Cement mortar 1:6 (1 cement : 6 Coarse sand) |
| 8 | Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels |
| 9 | ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 |
| 10 | Providing and laying in position cement concrete of specified grade excluding cost of centering and shuttering - All work up to plinth level :vi)1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 40mm) |
| 11 | ii)1:1/:3(1 Cement :1/ Coarse Sand: 2 Graded stone aggregate of 20mm) |
| 12 | Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: |
| 13 | Providing & fixing Klippon Galvalume steel profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) of bare metal thickness 0.50mm as per ASTM A446 having yield stress of 275mpa, surface shall have hot dip metallic coating of Aluminium Zinc alloy comprising of 55% aluminium,43.5% zinc & 1.5% silicon, with 5-7 micron epoxy primer and polyester top coat of 15-18 micron on both sides,total coated thickness(TCT) of 0.58mm.Sheet shall have protective guard film of 25 microns minimum to avoid scratches while transportation & should be supplied in single length up to 6m or as desired by Engineer-in-charge.i) Profile Sheet for roofing |
| 14 | Providing & fixing 15 cm wide 45 cm over all semi circular plain G.S. sheet gutter ,0.80mm thick with zinc coating not less than 275gm/m2 with iron brackets 40x3mm size,bolts,nuts & washers etc.including making necessary connections with rain water pipes complete. |
| 15 | Providing valleys of 90cm wide overall in plain G.S. sheet 1.60mm thick with zinc coating not less than 350gm/m2, fixed with polymer coated J or L hooks, bolts and nuts 8mm dia.. G.I. limpet : and bitumen washers complete OR G.S.Sheet on fascia of Canopy upto 1.0m width, fixing with rivets/screws etc in place of J/L hooks etc. |
| 16 | iii) Plain sheet for Flashings/ Aprons (Upto 600 mm) |
| 17 | Supplt and fixing of LED LED FLAME PROOF LIGHT FITTINGS ECRF -236L, EXD-IIB die cast Aluminium ( LM-6) IP 66 explosion proof cum light fittng , bottom opening type with 72 W LED unit , Alunminium polished internal reflector with 2 X 3/4\" ET entry without bland and blanking plug finish - Epoxy light grey shade 631 of IS-5. |
| 18 | CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items. iv) 3 Core x 2.5 sq. mm Copper Cable FRLS |
| 19 | CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compresson cable glands, crimping type lugs and allied jointing materials, etc. all complete as per specification and direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. vii) 3 Core x 2.5 sq. mm |
| 20 | Supplying, fabricating and installing following sizes of perforated GI cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling and/or fix to steel/RCC columns, beams or any other structure members with MS suspenders, angles, channels, etc complete as per the direction of IndianOil i) 100mm x 25mm x 2mm |
| 21 | Providing earthing with 80 mm dia,3.0 M long GI (Heavy duty) perforated pipe as per IS:3043 (with latest amendment) including providing suitable earth bus for interconnection, providing a mixture of salt & charcoal, making earth pit chamber with chequered plate cover as per standard Drwng. etc. all complete as per specif. & direction of Engineer-In-charge. |
| 22 | Supply of 1C x 6 Sq. mm FRLS Flexible copper insulated green wire for earthing instruments and junction boxes etc complete as per specification and tender document |
| 23 | Supply & Laying Earthing 50 x 6 mm G.I. Strip as per specifications and direction of Engineer in Charge. |
| 24 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture |
| 25 | Providing & fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work & fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.ii) 110 mm |
| 26 | CABLE BRICK DUCT Providing & constructing underground brick duct 650mm below GL for laying of 3 cables of max. diameter 70mm, complete with supply and laying of sand, bricks & including Excavation and backfilling in all kind of soils. i) 450 mm (24 Bricks & 0.0494 cum per Mtr) |
| 27 | Providing and laying class-B 50mm dia GI pipe for cable routing under flooring/ EB post leading including sealing both ends with jute and Bitumen |
| 28 | Centering and shuttering including strutting, propping etc. and removal of form for : i) Foundations,footings,bases of columns, etc. for mass concrete |
| 29 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Light Dutyii) 150 mm dia. R.C.C. pipe |
| 30 | Structural steel work riveted,bolted or welded in built up sections,trusses &framed work, including cutting, hoisting, fixing in position and Including Surface preparationof thestructures as per SA 2.5 &painting thesame with 1 coat of P1 primer(InorganicZinc ethyl SilicatePrimer),1 coat U1 :2 Pack Polyamid Cured Epoxy MIOUndercoat and 2coats of F1: 2 PackAlipathic Acrylic Polyurethane finishpaintofapproved colour and shade as perenclosed specifications & as persitedirection all complete: |
| 31 | Demolishing cement concrete manually/ by mechanical means including disposal of material outside premises at an unobjectionable place as per direction of Engineer-in-charge. i) 1:3:6 or richer mix (i/c equivalent design mix) |
| 32 | Demolishing brick work manually/mechanical means including stacking of serviceable material & disposal of unserviceable material outside premises at an unobjectionable place as / direction of Engg-in-charge |
| 33 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars & disposal of unserviceable material outside site to an unobjectionable place as/ direction of Engineer-in-charge |
| 34 | Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge. |