Tender For Construction Of Building Of Pre Fabricated Anganwadi Center Ked Panchayat Ked Block Barwadih Dist Latehar, latehar-Jharkhand

Rural Development Department has published Tender For Construction Of Building Of Pre Fabricated Anganwadi Center Ked Panchayat Ked Block Barwadih Dist Latehar. Submission Date for this Tender is 15-04-2024. Building Work Tenders in latehar Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

43126125
Tender For Construction Of Building Of Pre Fabricated Anganwadi Center Ked Panchayat Ked Block Barwadih Dist Latehar
Open Tender
Indian
Jharkhand
latehar
15-04-2024

Tender Details

Construction Of Building Of Pre Fabricated Anganwadi Center Ked Panchayat Ked Block Barwadih Dist Latehar

Key Value

Document Fees
INR 5000 /-
EMD
INR 49500.0 /-
Tender Value
INR 24.68 Lakhs /-

BOQ Items

Name of Work: CONSTRUCTION OF BUILDING OF PRE FABRICATED ANGANWADI CENTER KED PANCHAYAT KED BLOCK BARWADIH DIST LATEHAR
Sl. No. Item Description
1Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil itemA) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. 5.1.1
2Earth filling infoundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earthobtainedfrom excavation offoundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I.(mode of measurement compacted volume) 5.1.7
3Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume)5.1.10
4Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.5.6.3
5Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) 5.3.1.2
6Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level.1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) 5.3.9.1
78 mm
810 mm
912 mm
10Lintels, beams, plinth beams, girders, bressumers and cantilevers 5.3.17.5
11Foundations, footings, bases of columns, etc. for mass concrete 5.3.17.1
12Providing 6 mm thick cement fibre board on 9 mm thick cement fibre board for outer surface of building E/I. DSR 26.42.1 A
13Providing 12.5 mm thick gypsum board on 8 mm thick cement bonded wood particle board on Inner surface DSR26.43.2
14Providing wall putty on Inner side & Outer side of wall surface DSR 13.80
15Finishing walls with Acrylic exterior paint on outer surfaceDSR13.46.1
16Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I.5.8.18
17Supplying, and fixing fan hook of 16mm dia M.S. bar 1 meter long bent to required size and shape , placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/I. (where materials is not supplied by the deptt.)5.5.13
18P/F anodised aluminium grill DSR 21.17
19Providing Aluminium frame in window DSR21.1.1.2
20Providing Aluminium shutter in window DSR 21.1.2.2
21Providing glazing in window DSR 21.3.1
22Providing 4mm th. ACP in door DSR2631 (basic rate vol, I, Page 30)
23Providing 25mm thick 2nd class patent stone flooring (1:3:5) with 12mm, to 6mm size graded stone chips and top layer 6mm. Thicks (1:3) with 6mm down stone chips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royality with all complete as per building specification and direction of E/I. 5.6.8
24P/F False ceiling DSR12.45.1
25Providing polished granite in flooring DSR11.56.1
26Writting on walls DSR 13.71
27(A) Sand
28(B) S/Chips
29(C ) BRICKS
30(D) Cement Fibre Board And Gypsum Board
31STRUCTURE -Designing, providing, installing and fixing factory finished custom designed cold form Light Gauge Steel Framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. The steel sheet shall be galvanized (AZ-150gms Aluminium Zinc Alloy coated steel having minimum yield strength 300-550 Mpa) conforming to AISI specifications and IBC 2009 for cold formed steel framing and construction and also as per IS: 875-1987, ISO 800-1984 and IS:801- 1975. The wind load shall be as per provisions of IS 875 (part -III). LGSFS frame shall be designed as per IS: 801 using commercially available software such as Frame CAD Pro-11.7/ STAAD PRO-V8i/ ArchitekV2.5.16/ Revit architecture-2011 or equivalent. Proper usage of Connection Accessories like Heavy Duty Tension Ties, Light Duty Hold-ons, Twist Straps (to connect truss with wall frames), Strong Tie, Tie Rod, H-Brackets, Boxing Sections, L-Shaped Angles for better structural stability. The framing section shall be cold form C-type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched with dimple/ slot at required locations as per approved drawings. The slots will be along centre line of webs and shall be spaced minimum 250mm away from both ends of the member. The frame can be supplied in panelized or knock down condition in specific dimensions and fastened with screws extending through the steel beyond by minimum of three exposed threads. All self drilling tapping screws for joining the members shall have a Type II coating in accordance with ASTM B633(13) or equivalent corrosion protection of gauge 10 & 12, TPI 16 & 8 of length 20mm. The frames shall be fixed to RCC slab or Tie beam over Neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to AISI 304 and 316 at 500mm c/c with minimum embedment of 100mm in RCC (RCC to be paid separately) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. The item also includes the submission of stability reports duly examined and issued by any NIT/IIT. The rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above.
32INSULATION Resin Bonded Rockwool 48 kg/m3 SOR -7273
33Roof insulation -Providing fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Fibre glass wool conforming to IS : 8183, density 24kg / m3, 50mm thick, wrapped in 200 G Virgin Polythene bags, fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5 mm x 24 gauge wire mesh, for top most ceiling of building.
34Vapor Barrier- Providing and fixing in all exterior face panels breathable vapour barrier underneath the cement fiber board as per National Building Code 2009 complete as per direction of Engineer-in-charge.
35Roof sheet - Color coated trapezoidal ‘’ LYSAGHT TRIMDEK 1072’’Profile sheet manufactured with nominal 1072 mm supply width nominal 28 mm deep ribs with subtle square fluting in the five pan at nominal 203 mm center to- center.The end rib shall be designed for anti-capillary action, to avoid any seepage of water through the lateral overlap. The feed material is manufactured out of. ZINCALUME® steel resin coated, minimum metallic coating mass is AZ150 (150g/m²), minimum yield strengths of G550 (550MPa) complies with AS1397 or IS15961.COLORBOND® XRW is pre-painted steel for exterior roofing and wallingmetal Thickness (0. 50 TPT), Hi-Tensile steel with min.550 MPa yield strength, metallic hot dip coated with Aluminum-Zinc alloy(55% Aluminum, 45% Zinc as per AS 1397 - Zincalume® with Super Durable Polyester exterior paint system, total 25um DFT on topside and 10um DFT on reverse side complying with AS/NZS 2728- type 4 or IS15965- class 3 COLORBOND® Ultra is pre-painted steel for severe coastal or industrial environments (closer to source),SuperDurable Polyester exterior paint system, total 25um DFT on topside and 15um DFT on reverse side complying with AS/NZS 2728- type 4 or IS15965- class 3
36Flashing & Accessories
37RIDGE
38GUTTER
39Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes - 110 mm diameter
40110 mm Shoe
41STUDD - Galvanised Steel main Tee ceiling section Size 24x38x0.33 mm (3 metre long)
42SDS Screw -SS Screws of sizes for structural glazing
43Stainless Steel pipe - Providing and fixing Stainless Steel pipe and fitting of grade AISI 304 as per JIS standard 3448 complete with press type fitting (fitting shall be paid for separately) i/c fixing of the pipe with clamps at 1.00 m spacing including cutting and making good the walls including testing of joints complete as per direction of Engineer-in-charge. (The pipe length inserted in the fitting shall not be measured for payment) - 42.70 mm outer dia Pipe
44Scaffolding - Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding.
45SANATARY - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes concealed work -15 mm
46Providing and fixing gate valve of approved quality with complete job, 25 mm dia
47Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
48Providing and fixing male ended 15mm dia brass bib cock with complete job
49S/F/F PVC S.W.R pipe (Supreme) - 110mm
50Providing and fixing 15 mm size C.P. brass pillar cockC.I. body brass spindle pillar cock with complete job(C.I. Body brass spindle)
51Supplying, fitting and fixing vitreous white glazed earthen ware wash hand basin of Parryor Hindustan or any other with complete job
52Supplying, fitting and fixing vitreous white glazed earthen ware I.W.C. of parry Hindustan or any other with complete job , 580 mm long with 12.50 liter low level PVC Cistern
53Supplying, fitting and fixing stainless steel sink 610x510x200 mm
54MAKING SOAK PIT 2.5 M DIA. & 3.0 M DEEP
55Cost of Septic tank
56ELECTRIFICATION - Wiring for light point/ fan point/exhaust fan point / call bell point with 1.5 sq.mm FRPVC Modular typeGROUP - A
57S/F ceiling rose including connection etc.as reqd.
58S/F brass battan / angle holder including connection etc.as reqd.
595/6 amps switch
605/6 amps socket outlet
6115/16 amps switch
6215/16 amps socket outlet
63Electronic step fan regulator, mini
64ITC of ceiling fan
65S/F/F 1200 mm SWEEP CEILING FAN
66S/F/F 15/16W LED BULB
67S/F/F 12"" metal exhaust fan
68S/F S.P. MCB DB 2 way single door
69S/F "B" series, S.P. MCB 6/32 Amp single pole
70Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil itemA) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. 5.1.1
71Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume)5.1.10
72Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.5.6.3
73Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) 5.3.1.1
74Providing designation 75B brick work inC.M (1:6 ) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I.5.2.6
75Reinforcedcementconcreteworkinbeams,suspendedfloors,roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size). 5.3.11
76providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL)5.5.4
77Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick 5.3.17.20
78Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 with floating coat of neat cement in skirting including rounding of junctions with floor, curing, taxes and royalty all complete as per building specification and direction of E/I.5.6.10
79CARRIAGE OF MATERIALS- Sand
80Stone Chips
81Bricks
82Boring - 300 mm dia. deep borewell - supplying all materials, labours, tools & equipments for drilling (a) from 0.00 m to 50.0 m
83(b) from 51.0m to 125.0m
84Supplying, assembling, lowering and fixing in vertical position in bore well,UPVC casing pipe of required dia,200 mm nominal size
85Development of tube well in accordance with IS : 2800 (part I) and IS: 11189,
86Providing and fixing suitable size threaded mild steel capfor borewell of 200mm dia
87Providing and fixing suitable size threaded mild steel clamp for borewell of 200mm dia
88S/F1.5 HP submersible pump set having 100mm dia. including all taxes, royalty etc. all complete job as per direction of E/I.
89Supplying & fitting of standard make submersible pump starter panel board with arranement of all necessary protection, including all taxes, royalty etc. all complete job as per direction E/I.
90Supplying, laying, jointing & connecting 4mm sq. copper cable of Finolex/Havells make including all taxes, royalty etc. all complete job as per direction E/I.
91Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes external work 32 mm
92Goods & Service Tax (G.S.T.) @ 18%
93Labour Cess @1%
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail