Military Engineer Services-MES has published Tender For Addition Alteration To Officers Mess And Provision Of Stress Management Centre Along With Roofing Of Pathway At Icgs Vizhinjam& Addition Alteration To Building No P / 21 ( Store Rooms ) At Icgs Vizhinjam 8932 / E8. Submission Date for this Tender is 01-05-2024. Shed Construction Tenders in Thiruvananthapuram Kerala. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 24-Apr-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 01-05-2024 |
FileName | File Description | File Size |
93872e65-bb5a-4e3b-b24d-94865d496e30.html | Tender Notice | 0 KB |
8932Tender.pdf | Tender Document | 0 KB |
BOQ_726646.xls | Tender Document | 0 KB |
Tendernotice_1.pdf | Tender Document | 0 KB |
Sl. No. | Item Description |
1 | Cutting into old masonry to form toothings for and bonding in new brick or stone work including making good in cement mortars complete all as specified and as directed. |
2 | Forming Jambs etc to door / window opening, with new brick work built in C.M 1:6 including cutting toothing and properly bonding into old work, also facing, jointing and pointing to match with existing work complete. |
3 | Cutting openings, through brick walls for door, window and other openings or enlarging existing openings, converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc., to store and rubbish not exceeding 50 M all directed. |
4 | Demolition of brick work / PCC block masonary built in cement mortar of any despciption and at any position complete all as specified and as directed. |
5 | Taking down rolling shutter of any description exceeding 5 sqm but not exceeding 10 sqm each complete all as specified and as directed. |
6 | Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed. |
7 | Excavating in trenches, n exc1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil getting out complete all as specified and as directed. |
8 | Returning, filling in soil including spreading leveling, watering and well ramming in layers n.exc.25cm thick complete all as specified and as directed. |
9 | Demolition of cement concrete reinforced (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for unreinforced complete all as specified and as directed. |
10 | Removing excavated material exceeding 250 M and not exceeding 500 M and depositing outside MD land at a level not exc. 1.5 m above the starting point complete all as specified and as directed. |
11 | Material and labour for plain cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation filling and mass concrete including necessary form work complete all as specified and as directed. |
12 | Material and Labour for providing precast cement concrete type C1, 1:3:6 (20 mm graded stone aggregate) solid blocks exc 10 cm in width and setting in cement mortar 1:4 complete all as specified and as directed. |
13 | Material and Labour for rendering 15 mm thickin CM 1:4 on brick/concrete surface of walls, finished fair and even surface without using extra cement complete all as specified and directed. |
14 | Taking down cement plastering on concrete or Brick works surface racking out joints, hacking for key , scrubbing down with water etc complete all as specified and as directed. |
15 | Material and labour for rendering 10mm thick in Cement Mortar 1:6 on fair faces of brick walls or on concrete surfaces, finished even and smooth,without using extra cement complete all as specified and directed. |
16 | Preparing newly plastered surfaces of internal wall and applying two coats of acrylic distemper over a coat of alkali resistant priming paint complete all as specified and as directed. |
17 | Material and labour for preparation of new surfaces on wall and applying two coat of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali and fungal resistant, dirt resistant exterior paint of required shade(company depot tinted) with silicon additives @ 1.43 Litre/10 Sqm over and includingpriming coat of exterior primer applied @ 0.90 Litre per 10 Sqmover new surface complete all as specified and as directed. |
18 | Material and labour for Preparation of old treated surfaces of wall by washing, rubbing down and stopping of painted surfaces and applying one coat of acrylic distemper complete all as specified upto 4th storeys height all as specified and as directed. |
19 | Material and labour for Preparation of old decorated surfacesof ceiling/ soffits of chajja & canopy by wahing, rubbing down or steel wire brushingor scrapping down smoke soot, moulds, mass and effloroscent salts and applying one coat of white wash upto 4th storey height, complete all as specified. |
20 | Material and labour for 100mm thick plain cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregateas in sub base of floors including necessary form work all as specified and as directed. |
21 | Material and Labour for vitrified tiles 10mm thick (square/rectangular) light coloured, area of each tile exceeding 1 sqm and not exceeding 1.5 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed of 15mm thick in CM 1:6 complete all as specified and as directed. Note:- (i) The colour, shade and pattern shall be approved by the GE during execution work. (ii) No extra cost shall be allowed for Removing and refixing and necesary cutting of door etcif any required during execution of work. |
22 | All as per Item No.21 above but for vertical surface/skirting, dados and risers to steps etc... over and including backing coat/rendering of 10mm thick in CM 1:3 complete all as specified and directed. |
23 | Supply and fix powder coated Aluminium frame and partition wall with one or more rebates including joining cleats for fixing etc.all as specified and directed. (Thickness or powder coating not less than 50 micron) all as specified and as directed. Note: Quoted rate shall be inclusive of rubber beading, glazing clips. Glass pane shall be measured and paid separately. |
24 | Supply and fix powder coated aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, and sliding tower bolt 150mm long anodised aluminium snap beading, screws etc. complete all as specified and as directed. |
25 | Supply and fix powder coated,aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.), hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed. |
26 | Supply and fix door closer hydraulically regulated, designation No.3 universal type, of Aluminium (extruded section body)suitable for door shutters of 851 to 1000mm width and of weight between 61 to 80kg complete all as specified and as directed. |
27 | Supply and Fixing 5.5 mm thick sheet glass ordinary quality in square not exceeding 0.5 Sqm in each pane for fixing in aluminium joinery with rubber gasket as specified and as directed. |
28 | Supply and Fixing 5.5 mm thick sheet glass ordinary quality in square exceeding 0.5 Sqm in each pane for fixing in aluminium joinery with rubber gasket as specified and as directed. |
29 | Supply and fixing in repairsbevelled edge Mirror of selected quality glass 8mm thick fixed on walls with suitable packing and cushioning, complete all as specified and directed. |
30 | Supply & Fix stainless steel wire cloth 0.36mm nominal dia of wire and average widht of aperature 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
31 | Supply and fix Solar control film 50 micron reflective type sticked to glass panes as per instructions of manufacture"s complete all as specified and as directed. |
32 | Use and waste of Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams to rough finished surface of concrete for flat complete all as specified and as directed. |
33 | Materialand Labourfor RCC 1:2:4 type B1 nominal mix concrete using 20mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m spancomplete all as specified and directed. |
34 | Material and Labourfor TMT(CRS/HCR) bar 10mm dia and over, cut to length, bent to shape required, including cranking,bending spirally for hooping ,for columns,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
35 | Material and labour for TMT bars(CRS/HCR), 5 mm to 10 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed. |
36 | Excavation in post holes (or similar holes) each n exc 0.5 cum and getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n exc 25cm, watering and removing surplus soil to a distance n exc 50m and making good surface in hard and denseloose soil complete all as specified and directed. |
37 | Dismantling and removing of existingmachine pressed precast concrete interlocking paver block not exceeding area of 1Sqm each for facilitating excavation of post hole and refixing the same after fixing post laid over and including 50 mm thick sand cushion complete all as specified and directed. |
38 | Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed. |
39 | Removing excavated material exceeding 250 M and not exceeding 500 M and depositing outside MD land at a level not exc. 1.5 m above the starting point complete all as specified and as directed. |
40 | Material and labour for plain cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation filling and mass concrete including necessary form work complete all as specified and as directed. |
41 | Material and labour plain cement concrete 1:2:4 type B2 using 40 mm graded stone aggregate as in foundations and mass concrete all as specified and as directed. |
42 | Supply and fix structural steel work in tubular trusses including special shaped washer complete using ERW or induction butt welded tubes conforming to IS - 1161-1979 grade St.-240 all as specified and as directed. |
43 | Supply and fix mild plate(plain or chequerred), channel, square cut or notched(ordinary or counter sunk) forming holes with riveted, bolted or welded attachment to bottom of pipe conforming to Fe 410-W quality A(Gde-E-250) complete all as specified and directed. |
44 | Material and labour for applying two coats of synthetic enamel paint over one coat ofred oxide primer on new steel surfaces over 10 cm wide or girth including preparation of surface etc., complete all as specified and directed. |
45 | Supply and fixing Pre-painted galvalume aluminum zinc coating GI based Plain sheet roofing with yield strength (550 MPA) prepainted with aluminium (55%) and zinc (45%) alloy coating applied through continous hot dip process having tatal coated thickness (TCT) of 0.50mm with minimum coating mass on both sides @ 150gms/sqm in length and width as per site condition fixed with complete acessories as per manufacturer"s instructions throughthrough specialist agency and complete all as specified and as directed. |
46 | Supply and fix PVC(SWR) half pipes trapezoidal shape rain water gutter 150mm at top and 110mm at bottom width complete all as specified and as directed. |
47 | Supply and fix PVC pipe (SWR) single socketed in any length with rubber ring joint 110mm dia fixed to wall complete all as specified and as directed. |
48 | Supply and fix mild steel bands , straps, supports or stays for rain water pipes including bolts and nuts and similar work conforming to Fe 290, Gde E-165 all as specified and directed. |
49 | Material and labour for for applying two or more coats of 100% premium acrylic emulsion paint having VOC not less than 50 gm/lit and UV resistance as per IS 15489-2004, dust, alkali and fungal resistant, of approved shadewith silicon additives @ 1.43 lit/10Sqm over a coat of primer @ 0.9Lit per 10 Sqm complete all as specified and as directed. |
50 | Material and Labour for Preparation of old decorated existing external surfacesof walls and providing two coats of Cement Base paint complete all as specified. |
51 | Material and Labour for preparation of old decorated surfacesof ceiling/ soffits of chajja & canopy by brooming down with wire brushingor scrapping down smoke soot, moulds, mass and effloroscent salts and applying one coat of white wash upto 4th storey height, complete all as specified and as directed. |
52 | Material and labour for preparation of old treated wall surfaces by washing, rubbing, brooming down or steel wire brushing or scraping down smoke soot, moulds, mass and efflorescent salts, and applying one coat of coats of Cement Base paint complete all as specified and as directed. |
53 | Material and labour for preparation of old decorated wooden surfaces of any description exceeding 10 cm width or grith not otherwise specified and applying one coat of syntheic enemal paint all as specified and as directed. |
54 | Material and labour for 100mm thick plain cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregateas in sub base of floors including necessary form work all as specified and as directed. |
55 | Material and labour for 80mm thick machine pressed precast concrete interlocking paver block, any shape and size of M-40 grade conforming to IS 15658-2006 with grey cement and pigment laid over and including 50mm thick 6.3mm course aggregate cushioning, watering and consolidation in the same position complete all as specified and directed. |
56 | Material and labour for plain cement concrete 1:2:4 type B1using 20 mm graded stone aggregate as in kerb, mud stop rounded or chamferred edges completeall as specified and as directed. |
57 | Material and Labour for point wiring complete using 1.5 Sqmm PVC insulated unsheathed copper conductor, stranded cable (FRLS) upto and including working voltage 1100volts grade, drawn through and including PVC casing and caping including all accessories ISI marked including press fit white PVC open switch/surface board high strength and crack resistance and unsheathed copper conductor stranded cable (FRLS) earth continuity wire connected to DBs/sunken boxes/fittings of size 1.5 Sqmm Cross sectional area and all other metal parts with earth dolly for the following:-. (a ) onelight point controlled by one switch 5 Amps |
58 | (b ) onefan/ exhaust fanpointpoint controlled by one switch 5 Amps |
59 | (c) One 3pin socket outlet 5 Amps on independent board |
60 | (d ) One 3pin socket outlet 5 Ampsonsame board |
61 | All as per Item No.57 above, but 4 Sqmm size copper conductor cable FRLS and 4 Sqmm copper earth wire cable FRLS drawn through PVC conduit suitable sizeincluding provision of conduit andconduit accessories for power point/AC point on independent board. |
62 | Supply and fix Modular switch one way 6A, 1 Module complete all as specified and as directed. |
63 | Supply and fix Modular socket outlet 6A, 2/3 pin Module complete all as specified and as directed. |
64 | Supply and fix Modular Switch socket combintation, 3pin, 5 Amps flush type complete all as specified and as directed. |
65 | Supply and fixingin replacement of Modular switch socket combination 16 A 6 pin 3module complete all as specified and directed. |
66 | Supply and fixingin replacement of Modular fan regulator step type, 120 Watt complete all as specified and directed. |
67 | Supply and fix in repairs LED highbay light 100 watt energy saving environment friendly and robust LED luminaire with efficacy suitable for ceiling(Surface/suspened) IP65 complete all as specified and as directed. Make: Cat No.SAUCERGENXPROHBP100WLED757P60DBOLTG of Havells or equivalent in Crompton Greaves/Philps/Bajaj |
68 | Supply and fix LED tube light fitting with tube decorative ultra slim round profile LED lighting fixtures 18 Watt with extruded polycarbonate, envirmental friendly energy efficient ready to use pack,accessoriesprewiredand connecting up complete all as specified and as directed. Make : Cat No. LHEXBLP5PN1W018 of Havells or Equivalent in Crompton Greaves/Philips/Wipro |
69 | Supply and fix energy efficient BEE 6.00, 5 star rated high speed BLDC ceiling fan, air delivery 210 CFM, 1200mm sweep, including motor-blade set, downrod, shackle, assembly kit, canopy , Operating voltage 230 voltsingle phase complete all as specified and as directed. |
70 | Supply and fix in replacement of Ceiling rose in poly carbonate 3 plates flush type 6 Amps, 230 volts AC complete all as specified and directed. |
71 | Supply and fix MCB SP 6-32 amp rating 240V, 10KA "C" curve miniature circuit breaker (MCB) of single pole in the MCB DB,IP 20 transparent lebel holder fully insulated safety shutters suitable for cable up to 35 Sqmm cross sectional area complete including suitable size copper Lugs complete all as specified and directed. |
72 | Supply and fix MCB SPN 40 amp rating 240V, 10KA "C" curve miniature circuit breaker (MCB) of single pole in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
73 | Supply and fix Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, SPN 8 way with 200 Amps rated copper bus bar double doorprotection, neutral bar,earth bar, single pole and neutral 240 volts, MCBs used as incommerDouble door, flush to wall complete all as specified and directed . |
74 | Material and labour for Sub main wiring using two runs of single corePVC insulated cable (FRLS) 6 sqmm copper conductor multi stranded and one run of 6 sqmm copper conductor insulated cable (FRLS)using as earth wire drawn through and including suitable size PVC casing and caping including taking down old aluminium/CopperSub main wirng complete all as specified and directed. Note-3 run of 6 sqmm PVC copper wire and One run of PVC casing caping shall be measured and paid as oneunit. |
75 | Supply and install hi-wall split type AC unit indoor/ outdoor complete with cordless remort control unit and with in built air ioniser and plasma filter for better indoor air quality with with inverter AC single phase with all accessories of capacity 1.5 TR, 5 star rating as per BEE norms and fixed with necessary copper pipe and MS bracket duly painted with two coats of synthetic enamel paint over a coat of primer for fixing external compressor unit all as specified and as directed. Make: LG/Godrej/Blue star/Voltas/Daiken. |
76 | Supply and FixVoltage stabilizer for automatic operation, 4 KVA capacitysingle phase, naturally air cooled indoor type designed for input 170V to 270V with output voltage stablized at 230V with accuracy of ± 2.5% and with time delay complete all as specified and as directed. Make: V Guard/Voltas/Aplab/AE/Power Wave/ Microtech/ Numeric |
77 | Supply and fix wall mounting fan 450mm sweepsingle phase 230 volt connecting complete all as specified and as directed. Make:Havells /Usha/Crompton/Bajaj |
78 | Supply and fix in repairs LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make : Havells / Crompton Greaves / Philips / Wipro/ Bajaj |
79 | Schedule of Credit (Minus) Rs.8500.00 NOTE: Bidder shall insert credit amount of Rs. 8500.00 as ratein Green field under Col-13. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail