Tender For Special Repair Of Fire Alarm System Installed At Mini Sectt. Palwal, Palwal-Haryana

Public Works Department-PWD has published Tender For Special Repair Of Fire Alarm System Installed At Mini Sectt. Palwal. Submission Date for this Tender is 12-04-2024. Alarm Systems Tenders in Palwal Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

43092812
Tender For Special Repair Of Fire Alarm System Installed At Mini Sectt. Palwal
Open Tender
Indian
Haryana
Palwal
12-04-2024

Tender Details

Special Repair Of Fire Alarm System Installed At Mini Sectt. Palwal

Key Value

Document Fees
INR 1000 /-
EMD
INR 2400.0 /-
Tender Value
Refer document

BOQ Items

Name of Work :SPECIAL REPAIR OF FIRE ALARM SYSTEM INSTALLED AT MINI SECTT. PALWAL
Sl. No. Item Description
1SITC of addressable multisensor detector with a combination of Opticaland Thermalincluding mounting base, auto addressing feauture asrequired.Detetctor should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m.Shall be EN54/ VDs/UL certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module after 20 devices) Make: Bosch / Siemens Cerberus / GST
2Supply, Installation, Testing & commissioning of addressable Heat detector with fixed andrate of raise feature including mounting base with LED etc. complete as required.Each Detector should have 2as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m.Shall be EN54/ VDs/UL certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) Make: Bosch / Siemens Cerberus / GST
3SITC of intelligent Analog Addressable type Manual Call Point having Surface or flush mounting option fully compliat to EN 54 having Rotary Decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make: Bosch / Siemens Cerberus / GST
4SITC of Addressable Loop powered sounder with strobe / flasher complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make: Bosch / Siemens Cerberus / GST
5SITC of UL/EN54/LPCB listed and FM Approved Line Isolator for Isolating the section of circuit in case of short in the addressable Loop wiring Make: Bosch / Siemens Cerberus / GST
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail