Tender For Provision Of Deficient Md Accommodation For Officers And Additional/Alternator/Improvement To Smq/Omq At Afs Salua Under Ge (P) (Af) Kalaikunda, kalaikunda-West Bengal

Military Engineer Services-MES has published Tender For Provision Of Deficient Md Accommodation For Officers And Additional/Alternator/Improvement To Smq/Omq At Afs Salua Under Ge (P) (Af) Kalaikunda. Submission Date for this Tender is 13-05-2024. Building Work Tenders in kalaikunda West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

43091016
Corrigendum : Tender For Provision Of Deficient Md Accommodation For Officers And Additional/Alternator/Improvement To Smq/Omq At Afs Salua Under Ge (P) (Af) Kalaikunda
Open Tender
Indian
West Bengal
kalaikunda
13-05-2024

Tender Details

Tender For Provision Of Deficient Md Accommodation For Officers And Additional / Alternator / Improvement To Smq / Omq At Afs Salua Under Ge ( P ) ( Af ) Kalaikunda

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 26-Apr-2024 Corrigendum_1 BOQ 06-05-2024
2 06-May-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 13-05-2024

Key Value

Document Fees
INR 1000 /-
EMD
INR 274000.0 /-
Tender Value
INR 1.99 Crore /-

BOQ Items

Name of Work:PROVN OF DEFICIENT MD ACCN FOR OFFICERS AND ADDN/ALTN/IMPROVEMENT TO SMQ/OMQ AT AFS SALUA UNDER GE (P) (AF) KALAIKUNDA
Sl. No. Item Description
1NOTE (Applicable for all Parts/ Items):-The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
2SCHEDULE "A" Part - I (BUILDING / STRUCTURE)(Note: This schedule is not pre-priced by MES and the pre-priced rate indicated as 0.00 under column 5 signifies the fact only)
3Construction of single storied building for Offrs Md Accn(Sqn Ldr and above) with Permanent zonal specification,RCC framed construction complete all as specified and as shown on drawings.
4Construction of single storied building forServant Qtrcum Garrage with Permanent zonal specification,RCC framed construction complete all as specified and as shown on drawings.
5SCHEDULE "A" PART- II ( SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK) Details of prepriced Schedule is given in tender documents
6SCHEDULE "A" PART- III (INTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents.
7SCHEDULE "A" PART- IV (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
8SCHEDULE "A" PART- V (ROAD/PATH AND CULVERT) Details of prepriced Schedule is given in tender documents
9SCHEDULE "A" PART- VI ( AREA DRAINAGE) Details of prepriced Schedule is given in tender documents
10SCHEDULE "A" PART- VII (SEWAGE DISPOSAL ) Details of prepriced Schedule is given in tender documents.
11SCHEDULE "A" PART- VIII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
12SCHEDULE "A" PART- IX (EXTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents
13SCHEDULE "A" PART- X (COMPOUND WALL, FENCING AND GATE ) Details of prepriced Schedule is given in tender documents
14SCHEDULE "A" PART -XI (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES.
15S&F15mm bore fancy type chromium plated angle cock , screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed.
16S&F 125mm size chromium plated shower roses with 300mm long brass chromium plated shower arm ,with or without swivel joints, any size, including fixing to steel pipe or union, complete, all as specified and as directed.
17S&F pillar taps (Hot and Cold) of 15mm bore, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered "Hot" or "Cold" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed fency type complete all as specified and directed.
18S&Fbrass chromium plated fancy type wall mixer 2-in-1, 15mm borefor mixing hot & cold water screwed down for iron pipe and fixedcomplete all as specified and directed.
19S&F CP health faucet (ABS body)along with 1.25m long flexible tube and ABS wall hook including making connection and fixed in position complete all as specifiedand as directed
20S & FLED lamp 10 wattfixed to holder complete all as specified and directed.
21S & F LED lights fitting, 4 feet, 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
22S & F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
23S & F LEDsecuritylight fittingof capacity 35 wattwith integral reflector made of aluminium alloy LM6 with LED driver, lamp, surge protector and all accessories pre wired including connection with three core PVC insulated, sheathed copper conductor cable of suitable size complete with GI bracket 1.5 meter long bend to shape of dia 40mm GI medium grade pipe with MS clamp /nut & bolts/washers etc complete all as specified and directed.
24S & F LED wall bracket decorative light fitting 1 x9/10 watt polycarbonate body including LED light driver holderand LED bulb of B22 baseand connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
25S & F LED light fitting 1 x9/10 wattbulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
26S&F Energy efficient five star rated ceiling fan 230 volts, single phase AC, 1200 mm sweep,BEE 5 star rated , Brushless Direct Current(BLDC) without remote type with accessories like holding down rod,hanging clamps, blades, fan hook including writing MES number (as per standard practice)including provision of three core flexible copper wire of size 23/0076 from ceiling rose to ceiling fancomplete in all respect all as specified and directed. (Note : Fan regulator shall be provided with BLDC fan as per OEM recommendation)
27S&Fexhaust fan metallic steel body, single phase, 230 volts, 50 Hzs of size 300mm sweep, 900/950 RPM,heavy duty type with suitable metallic louver, blades, frameand flexible three core copper conductor cable of suitable size for connecting with ceiling rose complete including making of hole in wall and making good to the disturbed surface complete all as specified and as directed.
28S&F concealed distribution box, double door, vertical type, TPN, 415V,6 Way, IP 43 suitable for MCCB of 100/125 Amps, 4P, 16 kA as incomer and MCB SP/TP as out going complete with suitable bus bar, neutral link, earth link complete all as specified and directed. Note:(i) MCCB/MCBs shall be measured and paid separately (ii)Blank space shall be covered with blank plates and cost for the same shall be deemed to be included in the quoted rate.
29S & F TV coaxial cable socket, modular type complete all as specified and as directed.
30S & F Telephone socket single moulded, modular type with shutter complete all as specified and as directed.
31S&F electric water heater storage type steel body with stainless steel inner tank and heating element upto 1.5/2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, includingPVC connectionpipe for hot/ cold water to existing water lines,necessary fixing arrangementby using 50 X 5 mm MS plateand writing MES No and paste the instruction sheet of Do’s and DO NOTcomplete all as specified and as directed.
32Supply, testing, installation, commissioning of Kitchen Exhaust system (Chimney), filter less and dry heat clean technology, thermostatic touch control panel with 3 spped gesture motion, including matt black finish, black metal oil collector, motor with copper winding, black glass clad hood with LED insignia, front panel with black glass, energy saving LED light, metal blower + metal Housing, designed air flow (Max)- 1250 Nm3/h, Noice level- 58dBA (max), 5 years warranty, size -90 CM completeincluding fixing to wall, including fixing of duct and complete electrical wiring upto socket point as required for the chimney running complete all as specified and as directed.
33M&L for earthing complete with galvanised steel earth plate 600mm x 600mm x6mm thick elecrode and GI earth wire of dia 4.00mm as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to GI earth wire of dia 4.00mm as earth lead by means ofbolts, nuts, check nuts and washers (including welding) of galvanised iron or steel and connected to main switch board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type BI cover slab 54cm x 54cm x 5cm reinforced with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 15mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete all as specified and directed. [Note : (a)The unit rate includes for protection pipe and earth lead upto 7.5 m. Any variation in length of earth lead and protection pipe beyond 7.5 m shall be measured and paid seperately. (b)PCC pit (with pit cover) shall be provided at least 500mm away and not on the earth pit itself and cost of additional height of watering pipe, bends, elbow etc shall deemed to be included in the unit rate. (c)Excavation/earthwork is deemed to be included in the quoted rate.]
34Boring of holes under road, pavement, hard standing for inserting 40/50/80mm bore GItubing for drawing UG cable , getting out and disposal of excavated soil to a distance not exc 50 mtr from the site of work complete all as specified and directed.
35Supply, layingin trenchesfly ash bricks locally available of 230 x 115 x 75mmfor cable protectioncomplete all as specified and directed.
36M&L for earthing complete with galvanised steel earth plate 600mm x 600mm x3.15mm thick elecrode and 32mm x 6mm galvanised iron strip as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to GI strip 32mm x 6mm as earth lead by means ofbolts, nuts, check nuts and washers (including welding) of galvanised iron or steel and connected to main switch board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type BI cover slab 54cm x 54cm x 5cm reinforced with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 40mm GI tubing medium grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete all as specified and directed. [Note : (a)The unit rate includes for protection pipe and earth lead upto 7.5 m. Any variation in length of earth lead and protection pipe beyond 7.5 m shall be measured and paid seperately. (b)PCC pit (with pit cover) shall be provided at least 500mm away and not on the earth pit itself and cost of additional height of watering pipe, bends, elbow etc shall deemed to be included in the unit rate. (c)Excavation/earthwork is deemed to be included in the quoted rate.]
37M&L forHT Cable route indicator made out of MS plate 30cm x 20 cm x 5mm thick fixed on 1.5 mtr high angle iron of size 20 x 20 x 3mm duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and written as "HT Cable "in red colour paint , letters of 5 cm size, cable route indicator embedded in PCC (1:3:6) using 20mm graded stone aggregate ,of size 300 x 300 x 300mm with smooth finishing surfacecompleteall as specified and as directed.
38S & F Single pole and neutralenclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed.
39S & Ffor new concealed sub main wiring using two single core PVC insulated cable FRLS-ZH 4 sqmm copper conductor multi strandedand 2.5 sqmm copper conductorinsulated cable FRLS-ZH using as earth wire and drawing into PVC conduit complete all as specified and as directed.(Note: One runn of PVC conduit, Two runs of 4 sqmm and one run 2.5 sqmm copper wire measured as one unit).
40M & L for drilling and tapping cast iron water mains (in positions) for branch connections of the internal dia 25mm complete all as specified and as directed.
41Supply, Installation, testing and Commissioning step down transformer outdoor type plinth mounted, HT 11KV,3 phase 433 volts, 4 wire, 50Hz Delta/star connected, vector group DYN-II double copper wound, ONAN, manual type on load tap changing facility on HT side to vary secondary voltage of +7.5% in steps of 2.5% continuous rating of capacity not less than500KVA including bushing on HT and cable end box on LT side. The transformer shall confroming to IS-1180 part 1:2014 Level-3and BEE certified complete with all standard fittings and accessories gauges, first filling of transformer oil etc complete including suitable platform with PCC/brick work and finished with cement mortar 1:4 as per manufacture recommended length, width and height shall be 300mmx1750mm (foundation depth should be 750mm from ground level) 125mm thick RCC slab (1:2:4) all as specifeid and as desire Type B-1 (Nominal mix) using 20mm graded stone aggregate on top of the platfrom Reinforcement should be 10 mm dia @ 150c/c both way 02 nos ISMB 150 of CG/Scheider/Rajasthan Transformer/ITE Gurgaon
42Item No 11.27 Contd ...... (a) Oil conservation with filling hole and cap drain valve and oil level gauge. (b) Silica gel breather with connecting pipe, first fill of dehydratiing agent. (c) Explosion relief mounted on tank with double diaphragm and equalizer pipe connected to conservator air spoon (Pressure release valve) (d) Air release plug. (e) Oil temperature indicator (gauge) having range 00 C to 1200mm dia type. (f) Thermometer pocket with thermometer dial size 100 mm dia. (g) Drain valve with threaded adapter. (h) Sampling valve (j) cover lifting eyes. (k) Jacking pads, handling and lifting lugs. (i) Rollere type four No wheels. (m) Rating plate and terminal marking plate cable end box on LT side. Also extra bushing for neutral outside the LV side hand hole of sufficient size to assess the interior of the tank. (n) HT bushing on 11KV (p) First fillling of transformer oil. Notes:- (i) Contractor shall submit the general aggrangment drawing and details for approval before placing order. (ii) Factory Test at OEM Premisesshall be carried out by testing officer nominated by AO. (iii) Pre- commissioning testat site after installation of Transformer and connections shall be carried out SEI/EI.”
43Supply, fabrication , Installation , Testing and commissioning of factory madeLT control panel outdoor type of suitable sizehaving provision of double door openings into two halves with rubber beadings cubicaltype of suitable size as directed by the manufacturer, made out of 3.15 mm CRCA sheet compartmentalized with rubber beadings, angle iron 40 x 40 x 5 mm shall be used for making legs/ frame, duly powder coated internally and externally, including provn of Copper Busbar 1.5 times the rating of incomer,Bus Bar chamber shall be provided with inspection covers, bottom cover shall have provision for fixing and including suitable cable glands of required size and specification for LT Cable entry, each MCCB, Change over, Bus Bar chambers, measuring instruments, etc including prewiredshall have independent openings including provn of PCC Platform of suitable size PCC 1:2:4 all as directed by the Engineer-in-charge. The LT Panel comprising of the following:- 1). Incoming - ACB 4 pole 415 Volts adjustable thermal & fixed magnetic setting Ics=100% Icu type of capacity 800 Amps, 50 KA breaking capacity - 01 Nos 2). Outgoing - MCCB 4 pole 415 Volts adjustable thermal & fixed magnetic setting Ics=100% Icu type of capacity 200 Amps, 36 KA breaking capacity - 02 Nos 3). Outgoing - MCCB 4 pole 415 Volts adjustable thermal & fixed magnetic setting Ics=100% Icu type of capacity 100 Amps, 25 KA breaking capacity - 02 No 4). Outgoing - MCCB 4 pole 415 Volts adjustable thermal & fixed magnetic setting Ics=100% Icu type of capacity 63 Amps, 16 KA breaking capacity - 01 No 5). Space for Outgoing Spare MCCB- 01 No 6). VIF Digital meter with Suitable CTs for Ampere and Voltage display 7). LED Indicator lamp set of three colour Note : The rate quoted shall includedisconnectionof all existing Electrtical connectionsfrom existing LT panel and reconnecting with the new panel with new Thimbles and nut bolts, wahsers, etc.as directed by the Engineer in charge.
44Supply, fabrication, Installation , Testing and commissioning ofFactory made LT Bus BarFeeder Piller Box outdoor type having provision of double door openings into two halves with rubber beadings cubicaltype ofsize 1.00x0.75x0.40 Mtr as directed by the manufacturer, made out of 3.15 mm CRCA sheet compartmentalized with rubber beadings, angle iron 40 x 40 x 5 mm shall be used for making legs/ frame, duly painted with powder coated internally and externally, including Aluminium Busbar 300 Amps, and suitable cable glands of required size as per site requirement for LT Cable entry. Including PCC Platform of suitable size PCC 1:2:4 all as directed by the Engineer-in-charge. 1). Incoming - MCCB 4 pole 415 Volts adjustable thermal & fixed magnetic setting Ics=100% Icu type of capacity 200 Amps, 25 KA breaking capacity - 01 Nos 2). Outgoing - MCCB 3 pole 415 Volts adjustable thermal & fixed magnetic setting Ics=100% Icu type of capacity 63 Amps, 16 KA breaking capacity - 02 Nos 3). Outgoing - MCCB 4 pole 415 Volts adjustable thermal & fixed magnetic setting Ics=100% Icu type of capacity 40 Amps, 16 KA breaking capacity - 02 No 4). Space for Outgoing Spare MCCB- 01 No 5). VIF Digital meter with Suitable CTs for Ampere and Voltage display 6). LED Indicator lamp set of three colour Note : The rate quoted shall includedisconnectionof all existing Electrtical connections and reconnecting with the new panel with new Thimbles and nut bolts, wahsers, etc. and taking out old U/S panels as directed by the Engineer in charge.