| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 02-04-2024 | CORRIGENDUM 1 | BOQ | 22-04-2024 |
| 2 | 02-04-2024 | CORRIGENDUM 3 | Technical Bid | 22-04-2024 |
| Sl. No. | Item Description |
| 1 | Building, Landscaping & Parking, Service Road, PH & Sanitary, Fire Protection, Under ground tank. |
| 2 | Earthwork in excavation of foundation trenches in all kinds of soilupto and including 1.5metre lift and stacking the soil upto a lead of 100 metre and including dewatering, removing slush, shoring and strutting (as required), complete as per specification and as directed by the Engineer-In-Charge. |
| 3 | Cutting in disintegrated rock not requiring blasting to be removed by pick axes and crow bars and depositing materials within 50m lead and 1.5m initial lift including rough dressing as per direction and specification of the department including stacking useful materials separately as ordered. |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator with rock breaker) in foundation trenches or drains(not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming pof bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. complete as per the drawing, design including cost of all labour, T&P etc. as required for the work complete as directed by the Engineer-in-charge. In Hard Rock Blasting Prohibited |
| 5 | Upto 1.5m depth. |
| 6 | 1st extra lift beyond 1.50Mtr to 3.00 Mtr |
| 7 | 2nd extra lift beyond 3.00 Mtr to 4.50 Mtr |
| 8 | 3rd extra lift beyond 4.50Mtr to 6.00 Mtr |
| 9 | 4th extra lift beyond 6.00Mtr to 7.50 Mtr |
| 10 | Filling at all depth with available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 15cm in depth: consolidating each deposited layer by ramming and watering complete (lead upto 100m) as directed by the Engineer-In-charge. |
| 11 | Supplying and filling sand in foundation and over areas including watering, ramming, consolidating and dressing, labours, tools,etc., all complete as per the specification and direction of Engineer-In-charge. |
| 12 | Providing pre construction Antitermite treatment in foundation,trenches and plinth with Bayers company Premise midachlopride 30.5 sc chemicals and to be applied as per approved specifications etc complete. as per specification and as directed by the Engineer-In-Charge. |
| 13 | Providing and laying plain cement concrete 1:3:6 (1 cement:3sand: 6 stone agregate 40mm nominal size) as levelling course in foundation and plinth etc. includingtempering, curring, shuttering etc. complete all depth and height etc. complete as per specification and as directed by the Engineer-In-Charge. |
| 14 | Brick work with Fly Ash. Bricks (25cmx12cmx8cm) in cement mortar (1:6) in Foundationand andPlinth having crushing strength not less than 75.00 kg/cm2 immersing the bricks in water for not less than 6 hours before use (the bricks shall be free from cracks, well shaped, uniform in size and shall produce a clear metallic ringing sound when struck) includes molding, chamfering, corbelling .complete as per drawing, design and specification, watering and curing for 7days including cost, conveyance, royalty and taxes of all materials, labour, T&P etc. and as per direction of Engineer in charge.. |
| 15 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed andcleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portlandslag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending,etc. of M.S. rods or tor steel tying the grills and placing in proper position. |
| 16 | a) Footings |
| 17 | b) RCC Wall |
| 18 | c) RCC Slab |
| 19 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-30 grade as per approved designs and drawings having a minimum compressive strength (in work test) 300 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed andcleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portlandslag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending,etc. of M.S. rods or tor steel tying the grills and placing in proper position. |
| 20 | a) Columnup to plinth |
| 21 | b) Plinth Beam (Tie beam) |
| 22 | c) Column in S.S (i)up to 12\" level |
| 23 | GF |
| 24 | FF |
| 25 | SF |
| 26 | TF |
| 27 | ii) 12\" to 16\"level with double stage centring |
| 28 | GF |
| 29 | FF |
| 30 | SF |
| 31 | d) Lintel |
| 32 | GF |
| 33 | FF |
| 34 | SF |
| 35 | TF |
| 36 | e) Staircase |
| 37 | GF |
| 38 | FF |
| 39 | SF |
| 40 | f) Roof Beam at 16\" level with double stage centring |
| 41 | GF |
| 42 | FF |
| 43 | SF |
| 44 | g) Roof Slab at 16\" level with double stage centring |
| 45 | GF |
| 46 | FF |
| 47 | SF |
| 48 | h) wall up to 16\" level with double stage centring |
| 49 | FF |
| 50 | SF |
| 51 | i) Roof Beam ( TF ) |
| 52 | j) Roof slab ( TF ) |
| 53 | k) Roof Beam with triple stage centring ( TF ) |
| 54 | l) Roof slab with triple stage centring ( TF ) |
| 55 | Providing & fixing Thermo mechanically treated bars (Fe-500 D) Reinforcement bars of approved makefor RCC work of required diameter& of approved quality including straightening, cutting, bending, binding, welding , joining (if necessary), tying the grills, hoisting, lowering and placing in position as per the approved design & drawings with provision for fan hooks where required including the cost, conveyanceof reinforcement bars or tor steel and binding wires of 18 to 20 gauge, cost of all labour,loading, unloading, labour cess, T&P, etc. required for the work complete for the workin all heights as per the specification &as direction of Engineer-in-Charge. (Linear measurements will be taken & quantity will be calculated on standard weight. Weight of binding wire will not be considered for measurement. No payment will be made for overlap, couplings, welded joints spacer bars,stays, hangers and wastage. Cost of these items shall be deemed to be included in the rates for reinforcement) |
| 56 | GF |
| 57 | FF |
| 58 | SF |
| 59 | TF |
| 60 | Brick work with Fly Ash. Bricks (25cmx12cmx8cm) in cement mortar (1:6) in Super Structure having crushing strength not less than 75.00 kg/cm2 immersing the bricks in water for not less than 6 hours before use (the bricks shall be free from cracks, well shaped, uniform in size and shall produce a clear metallic ringing sound when struck) includes molding, chamfering, corbelling .complete as per drawing, design and specification, watering and curing for 7days including cost, conveyance, royalty and taxes of all materials, labour, T&P etc. and as per direction of Engineer in charge.. |
| 61 | GF |
| 62 | FF |
| 63 | SF |
| 64 | TF |
| 65 | Brick masonry work in cm (1:4) in superstructureusing fly ash bricks (25cmx12cmx8cm) having crushing strength not less than 75.00 kg/cm2 immersing the bricks in water for not less than 6 hours before use (the bricks shall be free from cracks, well shaped, uniform in size and shall produce a clear metallic ringing sound when struck) includes molding, chamfering, corbelling .complete as per drawing, design and specification, watering and curing for 7days including cost, conveyance, royalty and taxes of all materials, labour, T&P etc. and as per direction of Engineer in charge.. |
| 66 | GF |
| 67 | FF |
| 68 | SF |
| 69 | 12mm (1/2\") thick cement plaster (1:6) for finished smooth surface of brick walls after racking out the joints including watering and curing etc. comp. with cost conveyance, royalty of all materials and cost of all labour, T&P scaffolding required for the work complete as per the direction of EIC. |
| 70 | GF |
| 71 | FF |
| 72 | SF |
| 73 | TF |
| 74 | 16mm (5/8\") thick cement plaster with (1:6) for finished smooth to inside surface of brick walls in all floors racking out the joints including watering and curing etc. Complete. with cost , conveyance, royalty of all materials and cost of all labours, T&P scaffolding required for the work complete as per direction of EIC |
| 75 | GF |
| 76 | FF |
| 77 | SF |
| 78 | TF |
| 79 | 6mm thick cement plaster with (1:6) for finished smooth to RCC surfacein all floors with necessary chipping to rcc surface including watering and curing etc. Complete. with cost , conveyance, royalty of all materials and cost of all labours, T&P scaffolding required for the work complete as per direction of EIC. |
| 80 | GF |
| 81 | FF |
| 82 | SF |
| 83 | TF |
| 84 | Supplying fitting, fixing of 125 mm x65mm( after moulding ) well blend beautiful WPC ( Wood plastic composite choukath in door opening area tha wall surface of WPC Chaukaths 150mm anchor fastnerscrew cuttingthe holes filling the cutting holes in cement concrete (1:2:4) etcallcomplete as per direction of EIC. |
| 85 | GF |
| 86 | FF |
| 87 | SF |
| 88 | Providing and fixing of 12mm thick Clear Toughened Glass Frameless openable Door With approved brand Premium Fittings, Premium (9111198) Unilite Package BTS 75,UL PT 10 with Cover,UL PT 20 with Cover,UL US 10 Luck with Cover and PT 24, Premium (9137121) H Type Handle 450mm,12mm Clear Toughened Glass with Cutout and Hole, including the cost of all materials, hardware fittings, cost of alllabour, conveyance, loading, unloading, T&P, etc, complete as per the direction of Engineer-in-Charge. |
| 89 | GF |
| 90 | FF |
| 91 | Providing and fixing of 12mm thick Clear Toughened Glass Frameless sliddingDoor With rails and approved brand Premium Fittings.UL US 10 Luck with Cover and PT 24, Premium (9137121) H Type Handle 450mm,12mm Clear Toughened Glass with wheel runner and wheel runner, including the cost of all materials, hardware fittings, cost of alllabour, conveyance, loading, unloading, T&P, etc, complete as per the direction of Engineer-in-Charge. GF |
| 92 | Supplying, fitting, fixing of Un-plasticised Poly Vinyl Chloride (UPVC) approved brandfixed Ventilatorduly manufactured using UPVC reinforced profiles of 60mm x 55mm x 2.5mm for outer frames, Supplying, fitting, fixing of Un-plasticised Poly Vinyl Chloride (UPVC)Ventilatorduly manufactured using UPVC reinforced profiles of 60mm x 55mm x 2.5mm for outer frames, 75mm x 60mm x 2.25mm for casement window sash profile capable of mounting single glazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5mm prefabricated & welded through fusion welding the window sash shall be fitted with 8 mm thick clear toughened glass of SAINT-GOBAIN make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 No., per set of sashes and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing / deglazing at site etc. including cost and conveyance of all materials, accessiries, labour charges, materials and product conforming to ASTM D 638-14, EN-477-95 and other applicable codes and standards etc. complete as per direction of the Engineer-In-Charge. |
| 93 | GF |
| 94 | FF |
| 95 | Providing, fitting and fixing of 35mm thick BWR factory made flush door with both side lamination with 1mm thick laminates as per the specification complete with all materials, inclusive of all hardware material, hinges, nails, screws, doorknobs, handles, topper etc. including the cost of all materials, labour and T&P and overheads etc. complete. The exposed wood work shall be finished with automotive paint. two coats with primer. The rates also includes the cost of 40 x 25mm wooden beading for the partition in front of the door and finished with automotive paints and as per direction of EIC. |
| 96 | GF |
| 97 | FF |
| 98 | SF |
| 99 | Supplying, fitting, fixing 8 mm thick clear toughened glass of approved brand inVentilators on existing WPC frames with teak wood beadings of size 50X6 mmincluding cost all fiitings of all materialsetc. complete as per direction of the Engineer-In-Charge. |
| 100 | GF |
| 101 | FF |
| 102 | SF |
| 103 | Supplying fitting fixing of M.S. window Grillsusing 12mmx12mm size MS square bars, 20mmx5mm MS flats, MS angles of approved size for Grill , PCC(1:2:4) for clamp fixing cost & conveyance of all materials, labours , T&P, all fabrication, erection and fitting in position etc all complete as per direction of E.I.C. |
| 104 | GF |
| 105 | FF |
| 106 | SF |
| 107 | Supplying fitting fixing of M.S. railings using 20mmx20mm size MS square bars and 50 mm dia MS pipe including cost & conveyance of all materials, labours , T&P, all fabrication, erection and fitting in position etc all complete as per direction of E.I.C. |
| 108 | GF |
| 109 | FF |
| 110 | SF |
| 111 | Providing and fixing factory made 3 track 3 panel UPVC white colour sliding glazed window upto 1.50 m in height comprising of uPVC multi-chambered frame having section Frame 105 mm width x 49mm Height, Glass Sash: 37mm width x 61mm Height made out of lead free green profiles of wall thickness varying from 2.4 mmwith corners fusion welded, fully reinforced with Galvanized steel 1.2/2.0 mm confirming suitable wind load calculations as per IS 875 with maximum permissible deflection of 15mm for single glass and 8mm for double glass unit.The windows profile should fulfill the requirements of Viny 2010. The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weatherability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards. The window comprising of uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and including 6mm thick toughened glass of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. |
| 112 | GF |
| 113 | FF |
| 114 | SF |
| 115 | Supplying, fitting, fixing of Un-plasticised Poly Vinyl Chloride (UPVC) approved brand Ventilator with louvers duly manufactured using UPVC reinforced profiles of 60mm x 55mm x 2.5mm for outer frames, Supplying, fitting, fixing of Un-plasticised Poly Vinyl Chloride (UPVC)Ventilatorduly manufactured using UPVC reinforced profiles of 60mm x 55mm x 2.5mm for outer frames, 75mm x 60mm x 2.25mm for casement window sash profile capable of mounting single glazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5mm prefabricated & welded through fusion welding the window sash shall be fitted with 6mm thick clear toughened glass of SAINT-GOBAIN make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 No., per set of sashes and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing / deglazing at site etc. including cost and conveyance of all materials, accessiries, labour charges, materials and product conforming to ASTM D 638-14, EN-477-95 and other applicable codes and standards etc. complete as per direction of the Engineer-In-Charge. |
| 116 | GF |
| 117 | FF |
| 118 | SF |
| 119 | Providing and fixing factory made 3 track 3 panel UPVC white colour Fixed window upto 1.50 m in height comprising of uPVC multi-chambered frame having section Frame 105 mm width x 49mm Height, Glass Sash: 37mm width x 61mm Height made out of lead free green profiles of wall thickness varying from 2.4 mmwith corners fusion welded, fully reinforced with Galvanized steel 1.2/2.0 mm confirming suitable wind load calculations as per IS 875 with maximum permissible deflection of 15mm for single glass and 8mm for double glass unit.The windows profile should fulfill the requirements of Viny 2010. The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weatherability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards. The window comprising of uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and including 6mm thick toughened glass of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge..( SF ) |
| 120 | Providing and layingtile Cementi Dark Grey in floorings of size 600X1200mm of 9 mm thick laid on 20mm thick cement mortar 1:4 (1cement: 4coarse sand) including pointing the joints with white cement and matching pigments, etc. complete as per direction of Engineer-In-Charge at all floors and all heights. |
| 121 | GF |
| 122 | FF |
| 123 | SF |
| 124 | TF |
| 125 | Providing and layingtile Cement Dark Grey in Dados of size 600X1200mm of 9 mm thick laid on 12mm thick cement mortar 1:3 (1cement: 3coarse sand) including pointing the joints with white cement and matching pigments, etc. complete as per direction of Engineer-In-Charge at all floors and all heights. |
| 126 | GF |
| 127 | FF |
| 128 | SF |
| 129 | TF |
| 130 | Providing and layingMatte/Industrial Finish Vitrifiedfloor tiles 300x300 mm, 1st quality conforming to IS: 15622 ofapproved make, colours & shades, except white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1cement:4coarse sand) including pointing the joints with white cement and matching pigments, etc. complete as per direction ofEngineer-In-Charge at all floors and all heights. |
| 131 | Providing and fixing 20 mm thick stone Black Basalt 600X900 mm inflooring for steps,and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge etc. laid over 25mm thick bed of cement mortar 1:1 (1 cement: 1coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights.( GF ) |
| 132 | Providing and fixing 20 mm thick stone Black Basalt 600X900 mm inDado, Riser and skirtings(sample of Granitestone should be approved by EIC) for steps,and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge etc. laid over 12mm thick bed of cement mortar 1:3 (1 cement:3 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights.( GF ) |
| 133 | Providing and fixing 20mm thick Artifitial quartz slab Terra Cream3040x1250mm inflooring for stair case trade,and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge etc. laid over 20mm thick bed of cement mortar 1:4 (1 cement: 4coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights. |
| 134 | GF |
| 135 | FF |
| 136 | SF |
| 137 | Providing and fixing 20mm thick Artifitial quartz slab Terra Cream3040x1250mmfor stair case Riser,and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge etc. laid over 12 mm thick bed of cement mortar 1:3(1 cement: 3 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights. |
| 138 | GF |
| 139 | FF |
| 140 | SF |
| 141 | Finishing wall surface of walls with Acrylic wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials, cost of all labour, T&P etc. complete as per direction of EIC. (Make SG England/ J.K./Birla) |
| 142 | GF |
| 143 | FF |
| 144 | SF |
| 145 | TF |
| 146 | Providing and fixing Cluster Stone Brick Natural Red Cladding as per approved quality, design and specifications over 12mm thick CM 1:3 including scaffolding and cleaning the surface before cladding as per specification, instruction of Engineer-in-charge at all elevations including all material labour complete. in all floors and all heights. |
| 147 | GF |
| 148 | FF |
| 149 | SF |
| 150 | TF |
| 151 | Preparing surface and painting at all height with two or more coats of interior Plastic Emulsion of approvedshade as per the instructions of the manufacturers; giving uniform shade etcin all heights of walls etc. including interiorwall primer & providing scaffolding, cleaning, curing and supply of all materials and labour complete as per drawing, design and direction of Architect/Engineer-In-Charge. |
| 152 | GF |
| 153 | FF |
| 154 | SF |
| 155 | TF |
| 156 | Providing & Painting with synthetic enamel paint of approved brand and manufacture to give an even shade as per the instruction of Engineer - In-Charge at all floors and all heights including all material & labour complete. |
| 157 | GF |
| 158 | FF |
| 159 | SF |
| 160 | TF |
| 161 | Providing & Painting two coats with synthetic enamel paintover a coat of wood primer of approved brand and manufacture to give an even shade as per the instruction of Engineer - In-Charge at all floors and all heights including all material & labour complete. |
| 162 | GF |
| 163 | FF |
| 164 | SF |
| 165 | Providing and fixing Gypsum Board false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm ofrequired length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mmrunning at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of 12.5 mm thick gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 |
| 166 | GF |
| 167 | FF |
| 168 | SF |
| 169 | Providing and fixing Grid Mineral Fiber false ceilingat all heights of size 595X595mm of approved texture, design and pattern. The boards should have Humidity Resistance (RH) of 99%, Light Reflectance ? 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and Lshape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights etc complete. |
| 170 | GF |
| 171 | FF |
| 172 | SF |
| 173 | Providing and laying grading conc. 25mm (avg. thickness) cement concrete of required slope of mix 1:2:2 (1cement:2sand:2 graded stone aggregate of 6 mm nominal size) mixed with approved water proof compound as per manufacturer\"s specification on top of slab including cement slurry, all complete, including the cost of water proofing admixture, which should be approved by the Engineer-In-Charge prior to material procurement by the contractor. |
| 174 | GF |
| 175 | FF |
| 176 | SF |
| 177 | TF |
| 178 | Carriage of surplus earth to outside by mechanical means within 5 km lead including loading and unloading etc complete. |
| 179 | Providing and layingtile terrazzo World of size 600X600 mm in floorings laid on 20 mm thick cement mortar 1:4 (1cement: 4coarse sand) including pointing the joints with white cement and matching pigments, etc. complete as per direction of Engineer-In-Charge at all floors and all heights. |
| 180 | GF |
| 181 | FF |
| 182 | SF |
| 183 | Providing and layingtile terrazzo World of size 600X600 mm in Dados laid on 12mm thick cement mortar 1:3 (1cement: 3coarse sand) including pointing the joints with white cement and matching pigments, etc. complete as per direction of Engineer-In-Charge at all floors and all heights. |
| 184 | GF |
| 185 | FF |
| 186 | SF |
| 187 | Supplying fitting and fixing toilet Doors with partitions made out of Greenlam Sturdo Essentia Seren Suede 1995 cubicles as per approved drawings and doors 600X1785 mm of overal height 1995 mm with Aluminium rail,stopper channel etc as per specifications etc |
| 188 | GF |
| 189 | FF |
| 190 | SF |
| 191 | Supplying fitting fixing of powder coated M.S. Joists, MS plates, MS Chequered plates etcincluding cost & conveyance of all materials, labours , T&P, all fabrication, erection and fitting in position etc all complete as per direction of E.I.C. |
| 192 | GF |
| 193 | FF |
| 194 | SF |
| 195 | Providing and fixing cobble stone of size 4\"X4\"X1\" over 25 mm thick CM1:1 including pointing the joints with white cement and matching pigments, etc. complete as peras per specifications and direction of Engineer-In-Charge ( GF ) |
| 196 | supplying fiiting and fixing 32 mm thickflush Door Shutters made out of 32 mm thick approved quality WPC Board with all fittings and fixures etc complete |
| 197 | GF |
| 198 | FF |
| 199 | SF |
| 200 | Providing water proofing treatment by applying sika polyurethane water based elastic cold applied liquid membrane ie sikalastic 562IN over base layer ie sikalastic 11 primer W after cleaning the surface and as per Sika specification and direction of Engineer in charge. |
| 201 | GF |
| 202 | FF |
| 203 | SF |
| 204 | TF |
| 205 | Providing water proofing treatment( two componets glass fiber reinforced specially formulated acrylic modified cementious elastic coating system using sika top seal 109 @2.50 kg/sqm and sika feb 1 or equivalent (glass fiber cloth) including all cost conveyance labour T&P etc and as per Sika specification and direction of Engineer in charge. |
| 206 | GF |
| 207 | FF |
| 208 | SF |
| 209 | 25 mm thick AS flooring in CC 1:2:4 using 12mm to 20 mm size hard black grinite crusher broken chips with neat cement punning including watering, curingetc complete as per specifications and direction of Engineer in charge. ( GF ) |
| 210 | 12mm thick C.P.(1:4) with neat cement punning for finished smooth to masonry surface of brick walls after racking out the joints including watering and curing etc. comp. with cost conveyance, royalty of all materials and cost of all labour, T&P scaffolding required for the work complete as per the direction of EIC. ( GF ) |
| 211 | Providing fixing50 mm thick industrial GRPgratings with cost conveyance, and cost of all labour, T&P scaffolding required for the work etc complete as per the direction of EIC. ( GF) |
| 212 | Providing fixing50 mm thick industrial GRPMan hole coverwith cost conveyance, and cost of all labour, T&P scaffolding required for the work etc complete as per the direction of EIC. ( GF ) |
| 213 | SITC of Acoustic wall panelling of soak plane having NRC 0.71, fire class 1&P, density400kg/cum, Green VoC low, RC% low, Climate 0 degreee centigrade of size 1200mmX600mmX20mm to be fixed horizontally on CC25 GI channel/ aluminium channel of 50mmX25mm which area to be fixed vertically up to the appropriate height in three lines in the centre portion of the pillar at 300mm centre to centre leaving 0.45m on both side up to full height. The channel will be screw fixed with 50X10 PVC wall grip & 50X10 ND screw. The H-spline system is horizontally fixed on the CC25/aluminium channel by 25mm driver screw. The soak plane panel will be slutted-in to the H-spline system groove & pressed till the spline edge goes fully into the the panel. Then one more H-spline channel of1200mm of length to be pushed on the upper side of the panel & screwed properly, so likewise the installation of panels goes up. The cost includes all materials, labour, conveyance, scaffolding, T&P etc complete in all respect as per direction of EIC. ( SF ) |
| 214 | Supply and Installation of false ceiling12.5 mm gypsum perforated square edge 10/20 ( 10 mm square perforated 20 mm pitch TOA - 15 %) gypsum tiles having the technical parameters are as follows : Core - GFR gypsum, Fire – Class A & P, Acoustics – NRC 0.80,Climate (degree C RH) – 50, 90, Light reflectance 80 %,Green (RC %) – 25, Hygiene (VoC, Clean room) – Low , having pixel size 10X10 mm square perforated at 20 mm center tile of size 595 x 595 x 12.5 mm having density 700 Kgs/ m3, weight - 8 kg/m2 . The concealed ceiling system shall include GI Wall channel(WC 25) having thickness 0.45 mm, length 3600 mm, unequal flanges of 15 & 20 mm and web of 22 mm should be fixed along the perimeters of the wall with nylon sleeves and suitable fasteners at every 300 mm centers. Then suspend Main channels(MC 45) having thickness 0.9 mm, length 3600 mm, equal flanges of 15 mm and web 45mm from the soffit at every 1200 mm centers with Suspender angle(SA 25) having thickness 0.45 mm, unequal flanges of 25 & 10 mm. GI Cross channel(CC 25) having thickness 0.45 mm, length 3600 mm, knurled web 35mm, depth of 25 mm and equal flanges 9.5 mm is fastened to the Main channel in the direction perpendicular to the Main Channel at every 600mm centers. Now the jointing & finishing of the same will be done by usingjointing kit consist of powder mixed with water and apply the same with flat flap on the boards joints to finish the surface of the boards so as to look flush. Apply synthetic poly fiber PF 5 x 50 acoustic wool of 50 kg density to be kept on the top of the ceiling by laying on the framework. Test certificate of the use products shall be submitted after procurement of materials. The cost includes all materials, labour, conveyance, scaffolding, T&P etc complete in all respect as per direction of EIC. ( SF ) |
| 215 | Providing and laying 20 mm thick Kota stones above 0.1 sqm in flooringslaid on 25mm thick cement mortar 1:1(1cement: 1coarse sand) including pointing the joints with white cement and matching pigments, etc. complete as per direction of Engineer-In-Charge at all floors and all heights. ( SF ) |
| 216 | Providing and laying 20 mm thick Kota stones above 0.1 sqm in Dadoslaid on 12mm thick cement mortar 1:3 (1cement: 3coarse sand) including pointing the joints with white cement and matching pigments, etc. complete as per direction of Engineer-In-Charge at all floors and all heights. (SF) |
| 217 | Supplying fitting and fixing M.S.Panneled Door single leaved shutter with M.S.frame overall size including frame:- 1830mm (H) x 910mm (W) made out of the following materials conforming to relevant Indian Standard specifications. Frame :- 30x30x5mm M.S.angle, Shutter style :- Top & Bottom rail 25x25x3mm M.S.angle, Door panel :- 1.0mm C.R.Sheet. Panel stiffener covering width ofleaf :- 19x5mm M.S.Flat 3nos. Hinges size :- 100mm 3nos bought out as per ISS. Hold fast :- 30 x 30x 5mm M.S.Angle 150mm length bifurcated at the tip 3nos on each side. Handle :- 19x5mm M.S.Flat fabricated 2nos. Aldrop :- 2nos bought out as per ISS. Tower bolt :- 2nos bought out as per ISS. Approximate weight :- 36.50Kgs with all fittings and fixturesas per EPM specifications etc ( TF ) |
| 218 | Providing and fixing 150 mm dia PVC rainwater pipes schedule 80 in cement mortar 1:3 including cost of all materials,fiitings etc complete andas directed by the Engineer in Charge. ( TF ) |
| 219 | PARKING,SERVICE ROAD AND LANDSCAPINGEarthwork in excavation of open area in all kinds of soilupto and including 1.5metre lift and stacking the soil upto a lead of 100 metre and including dewatering, removing slush, shoring and strutting (as required), complete as per specification and as directed by the Engineer-In-Charge. |
| 220 | Earthwork in excavation of foundation trenches in all kinds of soilupto and including 1.5metre lift and stacking the soil upto a lead of 100 metre and including dewatering, removing slush, shoring and strutting (as required), complete as per specification and as directed by the Engineer-In-Charge. |
| 221 | Cutting in disintegrated rock not requiring blasting to be removed by pick axes and crow bars and depositing materials within 50m lead and 1.5m initial lift including rough dressing as per direction and specification of the department including stacking useful materials separately as ordered. |
| 222 | Supplying and filling sand in foundation and over areas including watering, ramming, consolidating and dressing, labours, tools, taxes etc., all complete as per the specification and direction of Engineer-In-charge. |
| 223 | Supplying and laying NP4 RCC Spun pipes with collars and rubber rings in CM 1:3in foundation bedincluding cost of transportation loading unloading etc all complete as per the specification and direction of Engineer-In-charge. |
| 224 | 450mm dia |
| 225 | 150mm dia |
| 226 | Providing and laying plain cement concrete 1:3:6 (1 cement:3sand: 6 stone agregate 40mm nominal size) as levelling course in foundation and plinth etc. includingtempering, curring, shuttering etc. complete all depth and height. |
| 227 | Providing and laying plain cement concrete of grade M20 using 20 mm down size chips etc as sub basecourse in service Roadetc. includingtempering, curring, shuttering etc. complete all depth and height. |
| 228 | Providing pre cast Kerb Stones of size 300X300X150 mm of M30 Grade concrete etc complete |
| 229 | Providing and fixing cobble stone of size 4\"X4\"X1\" over 25 mm thick CM1:1 etc complete as per specifications. |
| 230 | Carrige of surplus excaveted earth to outside by mechanical means within 5 Km lead including loading and unloading etc complete. |
| 231 | Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts. |
| 232 | Supplying and stacking of good earth at site including royalty and carriage upto 5 k m lead complete (earth measured in stacks will be reduced by 20% for payment). |
| 233 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts(cost of manure, sludge or extra good earth if needed to be paid for separately) |
| 234 | Holes 1.2 m dia and 1.2 m deep |
| 235 | Holes 90 cm dia, and 90 cm deep |
| 236 | Holes 60 cm dia, and 60 cm deep |
| 237 | Holes 45 cm dia, and 45 cm deep. |
| 238 | Making tree guard 53 cm dia and 1.3 m high as per design from empty coal tar drums, supplied free by the department, including providing and fixing 2 nos M.S. sheet rings 50 x 0.5 mm fixed with rivets complete in all respects including painting inside and outside of tree guard with: |
| 239 | Providing Circular Cement Concrete pots of specified size, cast with cement concrete of nominal mix 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 6 mm nominal size), reinforced with 7 Nos (3 nos horizontal & 4 nos vertical “ U “ shape) M.S. wires of 3.5 mm dia as per design, including required form work, finishing with cement punning on exposed surface, curing for specified period and stacking in required rows & height, all complete as per direction of Officer-in-charge. |
| 240 | Supplying and stacking sludge at site including royalty and carriage upto 5 km lead complete (sludge measured in stacks will be reduced by 8% for payment). |
| 241 | Filling of the following size empty pots with mixture of good earth & manure in the ratio of 2:1 (Two part of Good earth & one port of manure) and placing them on appropriate place i/c carriage of earth, manure and pots up to 50 mtr, as per direction of officer in charge. (The cost of good earth, earthen pots & manure will be paid separately.) |
| 242 | Providing and fixing grass turf with earthy 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light, watering with sprinkler and maintenance for 30 days or more till the grass establish properly as per direction of officer incharge. |
| 243 | Cutting of Hedge/Edge including removing of cut material, cleaning, hoeing of hedge/edge bed watering, manureing and applying insecticides and fungicides etc.(excluding the cost of material which shall be supplied by the department) and as per direction of officer in charge. |
| 244 | Complete maintenance of the entire garden features having as per yard stick in the garden area i.e. lawn trees, shrubs, herbs, edge, flower beds, foliages, creepers etc. including hoeing, weeding, pruning, replacement of plants, gap filling, watering, mowing of lawn, grass cutting by lawn mover and brush cutter, removal of garden waste, applying insecticide, pesticide & fertilizers (whenever required) top dressing of lawn with good earth and manure and maintenance of other garden related works as directed by office-in-charge (Cost of Good Earth, Manure, Fertilizer, Insecticide, Pesticide will be provided by the Department & lawn mover and brush cutter with fuel and other T & P material/articles shall be provided by the contractor.) and as per direction of officer in charge. |
| 245 | Providing and wartering of plants through water tanker of Horticulture features i.e. lawn, tree, shrubs, hedge/edge, ground cover etc. at the site of work. Water tanker having 5000 lit. capacity with one labour for watering i/c cost of water, filling of tanker, wartering at site with all leads and lifts as per direction of officer-in-charge. |
| 246 | Anti termite treatment by digging holes 300mm deep and 40 mm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration and as per direction of officer-in-charge.as per direction of officer-in-charge. |
| 247 | Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge. |
| 248 | Providing and displaying of Araucaria cookie plant, having ht. 1.80 m to 1.95 m, straight, well developed, fresh and healthy with lush green leaves from bottom to top in 30 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge. |
| 249 | Providing and displaying of Areca Palm plant, having ht. 1.80 m to 2.10 m with 8 to 10 suckers, well developed, fresh and healthy with lush green foliage in 30 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge. |
| 250 | Providing and displaying of Croton Golden specimen plant, having ht. 90 cm to 1.05 cm with 5 to 6 branches, well developed, fresh and healthy foliage in 30 cm size of Earthen pot/Plastic pot as per direction of the officer-in-charge. |
| 251 | Providing and displaying of Seaforthia Palm plant, having ht. 1.50 m to 1.80 m with 12-15suckers, well developed, fresh and healthy lush green leaves from bottom to top in 30 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge. |
| 252 | Providing and Displaying Golden Bottle brush Topiary well developed with fresh & healthyfoliage 5 to 6 big ball 115 to 180 cm ht in 40 cm Cement Pot as per direction of the officer-incharge. |
| 253 | Providing and stacking of Bottle palm of ht. 270-300 cm bottom girth 40-50 cm well developedin big HDPE bags as per direction of the officer-in-charge. |
| 254 | Providing and Displaying Chrysanthemum double variety, well developed, having 45 to 60cm ht., with 6 and above flowers with half blooming condition, fresh and healthy with bamboo stacking in 25 cm Earthen Pot and as per direction of the officer-in-charge. |
| 255 | Providing and stacking of Clerodendrum inerme of ht. 20 cm to 30 cm multi branched in 15 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge. |
| 256 | Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unsaverieable material’s as per direction of officer in charge (excluding cost of plant & water) |
| 257 | plantation per Tree |
| 258 | plantation per Hedge/Ground cover |
| 259 | WATER SUPPLY.Providing and fixing to wall or ceiling and floor rigid UPVC pipes class IV (8 kgf/cm²)/class III (6kgf/cm²) conforming to IS:4985/2000 and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification |
| 260 | Ground Floor |
| 261 | 20 mm dia U-PVC SH-40 pipe |
| 262 | 25 mm dia U-PVC SH-40 pipe |
| 263 | 32 mm dia U-PVC SH-40 pipe |
| 264 | 50 mm dia U-PVC SH-50 pipe |
| 265 | First Floor |
| 266 | 20 mm dia U-PVC SH-40 pipe |
| 267 | 25 mm dia U-PVC SH-40 pipe |
| 268 | 32 mm dia U-PVC SH-40 pipe |
| 269 | 50 mm dia U-PVC SH-50 pipe |
| 270 | Second Floor |
| 271 | 20 mm dia U-PVC SH-40 pipe |
| 272 | 25 mm dia U-PVC SH-40 pipe |
| 273 | 32 mm dia U-PVC SH-40 pipe |
| 274 | 50 mm dia U-PVC SH-50 pipe |
| 275 | supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings etc. all complete as per P.H. specification and direction of Engineer-in-charge. 250 mm thick wall (ALL FLOORS) |
| 276 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages as per direction of the E.I.C. (ALL FLOORS) |
| 277 | SANITARY FIXTURES.Supplying all materials, labour, T&P and fixing the following vitreous china WashWater Closet & cistern fitting (European type W.C. pan) of Hindware/Jaquar/Parryware with integral \"p\" or \"s\" trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of theEngineer-In-Charge. (JAQUAR-FLS-WHT-5353PPZ (Rimless Bowl With Cistern For Extended Wall Hung WC With PP Soft CloseSeat cover, Hinges, Dual Flush Cistern Fitting, Accessories Set, Size: 380x650x730 mm)) |
| 278 | Supplying all materials, labour, T&P and fixing Health Faucet of Hindware/Jaquar/Parryware complete with Chromium plated brass brackets fixed to wooden plugs with Chromium plated brass screws as per specification and direction of theEngineer-In-Charge. ( JAQUAR-ALD-577 Hand Shower (Health Faucet) with 8mm Dia, 1.2 Meter Long Flexible Tube & Wall Hook with N.R.V (Back Flow Preventer)) |
| 279 | Supplying all materials, labour, T&P and fixing standard sized two wayBib cock ofHindware/Jaquar/Parrywareof approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge. 15mm dia CP Two waybib cock with Flange. ( JAQUAR -FLR-5041N 2 Way Bib Cock with Wall Flange) |
| 280 | Supplying all materials, labour, T&P and fixing standard sized Wall mixer ofHindware/Jaquar/Parrywareof approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge. 15mm dia CP Two waybib cock with Flange. JAQUAR -FLR-5273UPR Wall Mixer with Provision For Overhead Shower with 115mm Long Bend Pipe On Upper Side, Connecting Legs & Wall Flanges |
| 281 | Supplying all materials, labour T&P and fixing Table topbasins of Hindware/Jaquar/Parryware with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing table top for wash basin recessed at the back for the reception of pipes and fittings,of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered \"Hot\" and \"Cold\" with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm diainlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of theEngineer-In-Charge. (Table top basin Jaquar FLS -WHT-5935, Pillar Cock Jaquar-FLR-5015, CP Waste Jaquar-ALD-727L130, Connection Pipe Jaquar-ALD 805B, Bottle Trap Jaquar-ALD769L300x190) |
| 282 | Supplying all materials, labour, T&P and fixing standard sizedChromium PlatedShower ofHindware/Jaquar/Parryware complete with Chromium Plated brassbrackets fixed to wooden plugs with Chromium Plated brassscrews as per specification and direction of the Engineer in charge. SHOWER HEAD,SHOWER ARM (Overhead Shower 150X150mm Squarel Shape Jaquar - OHS35495,Shower Arm 400X25X25mm Square Shape Jaquar- SHA455L400) |
| 283 | Supplying all materials, labour, T&P and fixing standard sized pillar cock ofof approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. 15mm dia brass pillar cock.(MAKE -JAQUAR) (Pillar Cock With Lift Type Operating Knob & Base Flange jaquar-FLR-5015) |
| 284 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C.sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of the Engineer-in-charge.JAQUAR-ACN-1191N Swivel Mirror 630 X 445mm Rectangular Shape. (JAQUAR-ACN-1191N Swivel Mirror 630 X 445mm Rectangular Shape) |
| 285 | Supplying all materials, labour, T&P and fixing standard sized15mm dia angular Stop cock of Hindware/Jaquar/Parrywareof approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge. (Jaquar -FLR-5053N Angular Stop Cock With Wall Flange) |
| 286 | Fixing Flat back Small urinal confirming to IS 2556: Part 6 -1996including connecting the urinal of 370x900x600 MM sizes with sensor respectively with wash pipe by means of white lead mixed with chopped hemp etc all complete as per specifications. (jaquar-CON-041KN) |
| 287 | Providing & Fixing granite slab with Table rubbed, edges rounded and polished of size 75x50 cm deep and 18mm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 as per direction of Er-in-charge. |
| 288 | Supplying all materials, labour, T&P and fixing standard sizedChromium Plated soap caseHindware/Jaquar/Parryware complete with Chromium Plated brassbrackets fixed to wooden plugs with Chromium Plated brassscrews as per specification and direction of the Engineer in charge. ( JAQUAR-ACN-1131N, Soap case) |
| 289 | Supplying all materials, labour, T&P and fixing standard sizedChromium Plated soap dispenser with glass bottleHindware/Jaquar/Parryware complete with Chromium Plated brassbrackets fixed to wooden plugs with Chromium Plated brassscrews as per specification and direction of the Engineer in charge. (JAQUAR -ACN-1135N soap dispenser with glass bottle) |
| 290 | Supplying all materials, labour, T&P and fixing standard sizedChromium Plated Paper Holder ofHindware/Jaquar/Parryware complete with Chromium Plated brassbrackets fixed to wooden plugs with Chromium Plated brassscrews as per specification and direction of the Engineer in charge.jaquar CAN-1153S |
| 291 | Supplying all materials, labour, T&P and fixing standard sizedChromium Plated brasstowel ring (Square) ofjaquar AKP-35721P Hindware/Jaquar/Parryware complete with Chromium Plated brassbrackets fixed to wooden plugs with Chromium Plated brassscrews as per specification and direction of the Engineer in charge. |
| 292 | Supplying all materials, labour, T&P and fixing standard sizedChromium Plated brass Towel Rack 600mm long with Lower Hangers, Stainless Steel ofHindware/Jaquar/Parryware complete with Chromium Plated brassbrackets fixed to wooden plugs with Chromium Plated brassscrews as per specification and direction of the Engineer in charge. Jaquar -AKP-35781PS |
| 293 | Fixing of 25 mm dia Brass/GM Fulway Valve confirming toIS : 781-1995 of approved makeas per specification complete as per direction of Er-in-charge. 32mm dia brass or gun metal full way valve.(Make- Zoloto or equivalent.) |
| 294 | Fixing of 32 mm dia Brass/GM Fulway Valve confirming toIS : 781-1995 of approved makeas per specification complete as per direction of Er-in-charge. 32mm dia brass or gun metal full way valve.(Make- zoloto or equivalent.) |
| 295 | Fixing of 50 mm dia Brass/GM Fulway Valve confirming toIS : 781-1995 of approved makeas per specification complete as per direction of Er-in-charge. 32mm dia brass or gun metal full way valve.(Make- zoloto or equivalent.) |
| 296 | Supply all materials, labour, T&P and providing fitting & fixing (Aqua guard)Aquaguard Blaze RO+UV+MTDS Water Purifier pure with water storage capacity 4 liters along with 2 nos of fancets 1 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc. all complete as per approved drawing, specification and direction of the EIC. |
| 297 | Supplying, fixing and testing of kitchen Sink Stainless steel kitchen sink - with drain board 510x1040 mm bowl depth 250 mm (NIRALI OLYMPIA MINI) |
| 298 | Supplying all materials, labour, T&P and fixing standard sized SINK cock ofHindware/Jaquar/Parrywareof approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification complete as per direction of Er-in-charge.JAQUAR-FLR-5347N |
| 299 | Fixing Rotational moulded Poly Propelene 3 - Layer WhiteRotational Moulded (5000 Ltr) Cylinderical Vertical water storage tanks (ISI marked)IS 12701-1996 including cutting holes through the tank and fixing mild steel tubes and fitting and providing extra sockets and jam nuts, fixing ball valve etc,including hosting upto a height of 5 mtr above ground level and placing the tank to the required postion etc all complete as per specification and direction of the Er-in-charge. |
| 300 | Procurement, supply, install and commission electrically operated Submersible type pump sets, with all protection sensors viz. temperature, oil leakage (if required), over load/under voltage tripping, electronic level sensing device for 3 level indication in UGR and auto cut off for dry run of pumps. (Should be with all necessary valves like NRV, Strainer & Butterfly valve) Electrical MCC in scope of work. Power connection to MCC will be Owner\"s responsibility. Interfacing with other contractors and Owner for smooth execution of work shall be vendor\"s responsibility. Details of pumps given below.Raw water pump, Cost of all materials to be included in the quoted rate and to be inclusive of all transportation, handling, supply of all other appurtenances and accessories, fasteners, miscellaneous items, labour for erection, trial run and commissioning + OH & P. No extra item shall be entertained. Monoblock Type pumps with Bronze impeller complete with common base plate coupling and guard,appropriate motor anddelivering100 lpm of water @ 25 mwc headMake Grundfoss / IIT / AMSTRONG / KIRLOSKAR.WITH TEFC, EEF-1 MOTOR, strainner.(Should be with all necessary valves like NRV, Strainer & Butterfly valve) (1W + 1S for Raw Water Pump ) |
| 301 | SEWAGE SYSTEM.Supplying all materials, labour, T & P and constructing of Inspection chamber(IC) of the following inside size with 8 cm thick R.C.C. precast cover slab in CC (1:2:4) mix using 12mm size h.g. chips, foundation concrete (1:4:8) using 40mm size h.g. metal on bed aound trap , Fly Ash brickwork in CM (1:6) in P&F and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mm x100mm size gully trap, 150mm x150mm C.I gratig etc. all complete as per aproved drawing, specification and direction of Engineer-in-charge. (Size- 760 x760x760 mm) |
| 302 | Providing and fixing square mouth S.W GULLY TRAP(G T) class SP-1 complete with CI grating brick masonry chamber with water tight CI cover with frame of 300X300mm size (inside),the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per the standard desifn. brick masonry chamber of size 180 X 150 mm size complete as per approved specification and direction of the Engineer in charge (Size- 300x300 mm) |
| 303 | Supplying all materials, labour, T & P and constructing of MAN HOLE chamber(M H) of the following inside size with 8 cm thick R.C.C. precast cover slab in CC (1:2:4) mix using 12mm size h.g. chips, foundation concrete (1:4:8) using 40mm size h.g. metal on bed aound trap , Fly Ash brickwork in CM (1:6) in P&F and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mm x100mm size gully trap, 150mm x150mm C.I gratig etc. all complete as per aproved drawing, specification and direction of Engineer-in-charge. (Man-hole chamber of size 900x800x450mm ) |
| 304 | Supplying, fixing and testing PVC soil, waste, Rainand vent pipes (SWR) SUPREME confirming to IS13592 : 1990, type B with rubber ring/Solvent(confirming toIS5382) joint inclusive of allnecessary specials like bends, tees,offsets, door bends, junctions, cowls, etc.,laid underfloor/ fixed on walls,and in pipe shafts etc., complete.The rate shall include necessary GI supports, GI grip bolts, angle brackets, hangers, supports as with suitable GI U-clamps, bolts, nuts and washers etc., The clamps shall be painted with two coats of enamel (approved) paint over a coat of primer etc., complete. Make:- Supreme/Ashirbad/Astral/Sentini |
| 305 | 110 mm dia . Rain water pipe |
| 306 | 110 mm dia Sewer line/ Waste water line |
| 307 | 75 mm dia Sewer line/ Waste water line |
| 308 | Supplying, fixing and testing PVC multi floortrap with SS frame and cover 110mm dia outlet fixed on a bed of cement concrete with (Heavy duty type) etc., complete.(ASTRAL -M252003207) 110 dia |
| 309 | Providing ,fixing , testing and commissioningof approved make PVC vent cowl with necessary accessories etc., complete. (ASTRAL-M212002707) (ASTRAL-M212002709)110 mm dia |
| 310 | Providing and fixing Clean Out, ASTRAL-M2420010109, 110 mm dia |
| 311 | Providing ,fixing , testing and commissioningof approved make 110mm diaP.V.C. SWR door bend 87.5\" l with necessary accessories etc., complete. |
| 312 | Providing ,fixing , testing and commissioningof approved make 110mm diaP.V.C. SWR plain bend 87.5\" l with necessary accessories etc., complete. |
| 313 | Providing ,fixing , testing and commissioningof approved make 110mm dia PVC SWR Single Ywith door with necessary accessories etc., complete. |
| 314 | Providing ,fixing , testing and commissioningof approved make 1110mm dia PVC SWR DoubleYwith doorwith necessary accessories etc., complete. |
| 315 | Construction 120 user septic tank of approved size inside dimension (4.5 mtr x 2.5mtr x 1.5 mtr depth) and drawing with Earth work, CC (1:3:6) in foundation with 1st class K.B Brick in C.M (1:6), 16mm CP in CM (1:6), 12mm thick CP in C.M (1:4), CC (1:2:4) using 12mm size h,b,g chips in floors with RCC (1:1 1/2 :3)Baffle wall, cover slab of thickness 100mm with CI manhole cover,110mm dia PVC vent pipe, PVC cowel and required PVC pipe including making of 1.8Mtr dia Soak way pit including laying of sewerage line of specified standard & diameter of approved make as required etc. complete as per specification and direction of EIC. (The drawing and design will be supplied by EIC). As per approved plan by EIC. |
| 316 | ONE BORE WELL (60mtr) Construction of 1 nos production wells including scientific source finding through consolidated and unconsolidated rock with down the hamer drilling rig or combination rig with pvc pipe and installation of submersible pump set with all acessories |
| 317 | Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the engineer in charge including use of own rig with its accessories ,tools and plant and consumables etc for lowering of 200mm/150mm dia G.I.P.V C/M.S casing pipes for housing fitted with socket and with or without well screen as for the necessity for soft ,medium,hard and boulder formation( G.I/P.V.C/M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well) 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only (Drilling of 200mm dia bore) |
| 318 | 00mtr to 30mtr |
| 319 | 30mtr to 45mtr |
| 320 | Drilling of 150mm dia bore (46mtr to 60 mtr ) |
| 321 | Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity form ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and dotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials, Lowering of 200mm dia P V C casing pipes 00mtr to 45mtr |
| 322 | Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance with DIN 2999 part-1/DIN-42225 PART-II specification length of pipe (laying length) will be 3 mtrs.The pipes shall be supplied with both external threaded with free socket. The pipe having external thread at one end i.e. female & or belled end . The female end having internal thread is to be belled in order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC/Rubber \"O\" ring to make the joint water tight color of the pipe shall be blue The name of the manufacture along with batch.No class of pipe shall be stranded legibly of each pipe length. 200mm dia PVC (sch-80) pipe |
| 323 | Supplying all materials, labour, T & P and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m below ground level (as per drawing) to plug the bore hole excluding cost of cement all com |
| 324 | Cleaning & developing the tube well with supply of compressor worked till clear & adequqte discharge is obtained from the tube well including supply & use of all necessary equipment & labour as per directin of the Engineer in charge. By DTH Rig |
| 325 | Supplying all materials, equipments,labour & conducting reconnaissance survey , integrated Hydrological & Geophysical (Electrical resistivity Method) survey & selection of potential source for exploration of ground water including selection & recommend, Rocky terrain with boulder formation for 300m depth |
| 326 | Supplying all materials, labours, T&Pand providing fitting & fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase /1 phase line voltage ranging from 320 volt to 450 volt conforming to Si 8034/89 with following specifications with suitable control panel ,jointing with GI/PVC/HDPE pipes,electrification,testing, commissioning ,trial running, conveyance of all materials to worksite , payment of taxex etc all complete as per specification & direction of the Engineer in charge (Texmo/crompton Greaves/ Kirloskar make) 2HP Single phase 3 stage vertical/Horizontal submersible pump set at head renge of 30 to 65 mtr with discharge capacity 155 to 110 L P.M with outlet dia 32mm |
| 327 | Dol Control panel |
| 328 | 40mm dia steel short piece |
| 329 | Well cap |
| 330 | 50mm size CI bracket |
| 331 | 25 sqmm flat cable |
| 332 | 20 mm dia rigid UPVC pipes |
| 333 | Steel ropes with cover |
| 334 | Supplying all materials ,labour, T&P and providing and fixing to wall or celling and floor HDPE pipes and pipe fiting conforming to IS: 4984/2000(10KGF/SQCM) of the following nominal bore with clamps & joining by Fusion welding method including testing making good the wall celling & floor all complete as per specificaations 7 direction of the engineer in charge. 32mm dia HDPE pipe |
| 335 | Borewell chamber.Supplying all materials, labour,T&P constructing Bore Well protection chamber of the size 650x650x1000 hight with cement concrete (1:3:6) using 40mm size hard granite metal on foundation,1st class fly ash brick work in cement mortar (1:3) with base cement concrete (1:2:4) using 12mm sizeh hg chips,12mm thick cement plaster (1:4) inside and outside,RCC cover slab in (1:1.5:3)using 12mm size h g chops, earthwork in excavation in all kind of soil anf refilling the cavity around the chamber including watering,cunning,conveyance of all meterials to worksite,payment of royalty,taxes etc all complete as per approved specification and direction of Engineer in charge. |
| 336 | SEWAGE TREATMENT PLANT OF 100 KLD CAPACITYMECHANICAL(MAKE-WATER ODISHA)Design, supplying, installing, testing & commissioning of SewageTreatment plant of capacity 100 KLD(excluding all Civil & construction work) for the following duty:Nature of Sewage- Domestic Sewage, Daily average flow -125 cum/day, pH - 6.5 – 8.5, BOD5 - upto 100-200 Mg/L, S. Solids - 100-250 Mg/L, COD - upto 400 Mg/L, Oil & Grease - 30 Mg / L, Coliform - 106 - 107 MPN/100 ML, Sewage discharge standard after treatment, PH - 5.5-9.0, BOD5 - Less than 20 Mg/L, S. Solids - Less than 20 Mg/L, COD - Less than 50Mg/L, Coliform – traces |
| 337 | Supply, installation, testing & commissioning of Stainless Steel Perforated, 6mm perforated Bar Screen with suitable lifting arrangementwith brackets in the sreen sump of (size 600 mm x 2500mm depth approx), SS-304 |
| 338 | Supply, installation, testing & commissioning of electronic type level indicator, instrumation and controller for automatic operation of the system with high/low level alarm complete with auxillary NO/NC contacts. Contractor shall ensure submission of detailed GA drawings (Plan & Section), P & I diagram, schematic diagram for the above mentioned component and additional component if so required for the complete working of the STP. |
| 339 | Supply, installation, testing & commissioning of non clogging typeMono block centrifugal sewage transfer pumps capableofhandlingsolidsupto 32 mm having C.I casing& Bronze impeller completewithallaccessories,motor of required capacity,Pressure gauge on delivery line with isolationcock,levelcontroller (withwiring) to controlthelevelofsump automaticallyCapacity 3-5 M3/hr each ,1 set = 2 Nos.(1 working + 1 standby), Head 10-15 Mts, Power1Hp, RPM2900, Make- KIRLOSKAR/CG/LUBI/TEXMO |
| 340 | Supply, installation, testing & commissioning of non clogging type Mono-block centrifugal sludge transfer pumps capableofhandlingsolidsupto 25 mm having C.I casing& Bronze impeller completewithallaccessories,motor of required capacity,Pressure gauge on delivery line with isolationcock,levelcontroller (withwiring) to controlthelevelofsump automaticallyCapacity 5 M3/hr each ,1 set = 2 Nos.(1 working + 1 standby)Head 10-15 MtsPower1 HpRPM2900Make- KIRLOSKAR/CG/LUBI/TEXMO |
| 341 | Twin lobetype rotary air blowers with 1450 rpm suitable motor(1W + 1Sb) capable of delivering65 cum/hr ( 2 nos. ) of free air at 0.4 kg/cm2 driven through “V” belt or directly coupled through flexible coupling to a TEFCmotor of suitable 3 HP Suitable for 415 ± 10% volts, 3 phase, 50 cycles A/C supply. complete with silensors,filters ,NRV,SV and divert valaves,Vibration pads etc complete with all acessories 1set=2 Nos (1 working + 1 standby), Make-A1/EVEREST / AIRVAK/AKASH, Motor Make SIEMENS/CROMPTON/KIRLOSKAR |
| 342 | Supplying, installing, testing and commissioning, of fine bubble diffuser along with membrane of silicone membranes,PVC support pipe(10 ksc pressure rating),PVC fitting, nylon rope braided hose with all accessories to make it retrievable & to provide clog-free oxygen for Aeration Tanks. |
| 343 | MBBR MediaModule as per std specification and detailed drawing and technical spec, quantity required as designed (approx 2.5-m3 each ) withsupport rest etc for the proposed MBBR directed by engineer in charge at site Make-- COOLDECK/MM AQUA/WELCOME MARKETING |
| 344 | Hexagonal Tube settler with MSEP rack support and open able bracket/MH and support frame for clarifier unit of size 750 mm long and with end locking arrangement ,the inclination of 51’ is required ,end lock sud have the surface locking arrangement in rack etc (media min approx 10 m3) with all fittings and fixtures as required for clarifier as directed by engineer in charge at site. Make-- COOLDECK/MM AQUA/WELCOME MARKETING |
| 345 | Piping (heavy class) in MS/GI/SS/UPVC/HDPE as per the approval of the consultants, to be designed for suitable and corrosion resistance complete or as directed by engineer in charge at site MS PIPE MAKE -JINDAL/TATAUPVC PIPE AND FITTINGS -- SUPREME/ASHIRBAD/FINOLEX |
| 346 | TERTIARY TREATMENT PLANTSupplying, installing, testing and commissioning ofhorizontal single/multistage centrifugal filter feed pump complete ,impeller CI casing . Each pump shall have TEFC 2900 RPM three phase electric motor. The pump shall have cast iron head, base plateSS Shaft/ Impeller/ Intermediate chamber. Pump shall be provided with mechanical seal. The pump shall be suitable for auto/ manual operation. of capacity 5 M3/hr @ 35 MWC.(1 W + 1 St by ) MONO-BLOCK PUMP,1 set = 2 Nos.(1 working + 1 standby)Head 30-35 MtsPower1.5 HpRPM2900Make- KIRLOSKAR/CG/LUBI/TEXMO |
| 347 | Providing, fixing, testing& commissioning ofFRPTertiary filtrationplantMULTI GRADE FILTER(suitablefor3.5 Kg/Sqcm workingpressure)completewith initial charge with Gravels/pebbles/sand /silex media, Multiport valves with built in frontal pipe work with back washsystem, pressure gauge at inlet, outletandback wash (each with isolation cock), valves,fittings associatedworks. Pr Vessel MOC – FRP COMPOSITE VESSELPr Vessel dia/hos – 525 x 1550Back WashPeriod12Hrs.Operating Pressure 3 Kg. per sq.cmTest Pressure7.5 Kg. Sq.cm.Capacity 5 m3/HrMake- ION EXCHANGE/PENTAIR/AQUANOMICS |
| 348 | Providing, fixing, testing& commissioning ofFRPwaterfiltrationplantACTIVATED CARBON FILTER(suitablefor3.5 Kg/Sqcm workingpressure)completewith initial charge with Gravels/pebbles/Activated carbon, Multiport valves with built in frontal pipe work with back washsystem, pressure gauge at inlet, outletandback wash (each with isolation cock), valves,fittings associatedworks. Pr Vessel MOC – FRP COMPOSITE VESSELPr Vessel dia/hos – 525 x 1550Back WashPeriod12Hrs.Operating Pressure 3 Kg. per sq.cmTest Pressure7.5 Kg. Sq.cm.Capacity 5 m3/HrMake- ION EXCHANGE/PENTAIR/AQUANOMICS |
| 349 | Supply, installation, testing & commissioning of Hypochloridedosing system for tertiary water treatment with 100 L .HDPE/PVCtank with lidetc Capacity of the dosing Pump -0-4 LPHPressure- 4 Kg/cm2Stroke per minute-55Make- KANAKDHARA/MILTON ROY/E-DOSE |
| 350 | ELECTRICAL INSTALLATION FOR STPDesign, fabrication, assembling, wiring, supply, installation, testing and commissioning of motor control centre shall be fabricated out of 14 gauge CRCA sheet steel in form in 3b formation with reinforcement of suitable size angle iron, channel ‘T’ sections irons and/or flats wherever necessary. Cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before painting as per specifications with 2 coats of red oxide primer and final approved shade of powder coated paint. 2 Nos. earthing terminals shall be provided for 3 phase, 4 wire, 50 Hz supply system. Lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel before fabrication. Cadmium Plated hardware shall be used in fabrication of panels. Quoted rates shall inclusive of cables (in accordance to specification) with earthing from panel to each motor /STP Motor Control Centre.IncomingDistribution panel with bus bar etc as std required. MCC for GWTP as described above CABLE & CABLE TRAYSSupplying & laying offollowing 1100 voltgradePVC sheathed aluminum/copper conductor armoured cables as per specification in existing trenches, cable trays, ducts over bed of sand, clamped to wall with suitable clamps, saddles fixing bolts including connecting testing and commissioning. as site suitable quantities as per site. 4 core 4 sq. mm copper cable, 8SWG Cupper wire, Make- L&T/SIEMENS |
| 351 | A. COMPLETE COMMISSIONING OF SEWAGE TREATMENT PLANT WITH UREA, DAP, COW DUNG, BIO-CULTURE, MAN POWER ALONG-WITH TOOLS AND TACKLES FOR 20 DAYS.B. 1 YEAR MAINTAINANCE SERVICE AND REPLACEMENT WARRANTY(BUT EXCLUDES MAN-POWER,CONSUMABLES ,ELECTRICAL ETC)C. INLET AND OUTLET PARAMETERS TEST REPORT AFTER SUCCESFUL COMMISSIONING FROM POLLUTION BOARD APPROVED LABORATORY. |
| 352 | FIRE PROTECTION SYSTEM PUMPS Supply, installation,testing and commissioning of Eleetric devine Main Fire Pump suitable for automatic operation and consisting of following, complete in all respect, as required: Horizontal type,multistage, centrifugal, split casingpump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS-1520. Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation,conforming to IS-325. M.S. fabricated Common base plate, coupling , coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti pads. 2280 Ipm at 70 m Head |
| 353 | Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required:(Jockey pump) Horizontal type, multistage,centrifugal pump of cast iron body and bronze impeller with stainless steel shaft,mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with Class-\"F\" insulation, conforming to IS : 325.M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 Imp at 70 m Head |
| 354 | CONTROLS PANELS Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabrical out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors,dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessorise, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase,50Hz Ac Supply with enclosure class IP 42 as per required.INCOMING: 250A, 50kA 4 Pole MCCB,Ics=100% Icu rating, Digital Voltmeter 0-500V with selector switch, Digital Ammeter (0-250) with selector switch & CTs etc., Main Fireb Pump amd spare pump2 X 125 A, 50kATPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor completewith all acceessoriseand internal wiring required for automatic operation, selector for local/remote,auto/manual/OFF operation.Jockey Pump 63A,50kATPN MCCB,Ics=100%Icu, with suitable HP fully autometic Star/Delta starter with overload protecction, current sensing phase preventor complete with all acceessorise and internal wiring required for automatic operation, selector switch for local/manual/OFF operation. |
| 355 | PIPES & ACCESSORIES Providing laying, testing& commissioning of \"C\" class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbowa, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 150mm. Dia |
| 356 | Providing, laying, testing&commissioning of \"C\" class heavy duty MS Pipe conforming to IS3589/IS1239 incuding Weling, fitting like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the pipe on the wall/ceilling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: |
| 357 | 25 mm dia |
| 358 | 32 mm dia |
| 359 | 40 mm dia |
| 360 | 50 mm dia |
| 361 | 65 mm dia |
| 362 | 80 mm dia |
| 363 | 100mm dia. |
| 364 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gnmetal/Stainless Steel cap and chain as required: Single headed Stainless steel |
| 365 | Supllying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmental/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmental/Stainless Steel cap and chain as required: Single headed Stainless steel |
| 366 | Supplying , fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmental seat duly ISI marked complete with nuts, bolts, washer, gaskets conforming to IS 13095 of following sizes as required: 100mm dia. |
| 367 | 50mm dia. |
| 368 | 80 mm dia |
| 369 | 150 mm dia |
| 370 | Providing, installation, testing and commisioning of non-return valve of following sizes conforming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washer etc. as required: 150 mm dia |
| 371 | 50 mm dia |
| 372 | Providing, installation, testing and commisioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.150 mm dia |
| 373 | Supplying and fixing 63 mm dia. 15 m long RRL hosepipe with 63 mm dia male and female coupling duly bound with GL wire, rivets etc. conforming to IS 636 (type-A) as required: Stainless Steel (Grade 304) |
| 374 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required: 20 mm nominal internal dis water hose thermoplastic (Textile reinforced) type-2 as per IS: 12585, 20 mm nominal internal dia gun metal globe valve & nozzel.Drum and brackets for fixing the equipments on wall. Connnections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 40 m |
| 375 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzel conforming to IS 909 suitable for instantaneous connection to incorrect hose pipe coupling as required: Stainless Steel (Grade 304) |
| 376 | Supplying and fixing of fire bridge connection of cast iron body with gun metal male instantaneous inlet coupling complete with cap and chain as requ. For suitable dia MS pipe connection conforming to IS 904 as required: 3 way- 150 mm dis M.S. pipe |
| 377 | Supplying and fixing air vessel made of 250mm dia, 8 mm thick MSsheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metel wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. |
| 378 | Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessorise: Pendent Sprinkler |
| 379 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. required. |
| 380 | Providing & fixing of pressure gauge in M.S. pipe line including connection etc. required. |
| 381 | Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 100mm dia. |
| 382 | Supplying, installation, testing and commissioning of sprinkler flexiblepipe (UL Listed) of stainless steel complete with 15 NTP on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25 mm NPT male thread to sprinkler head (Outlet) 15mm NTP female with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required: 700 mm |
| 383 | Providing, installation, testing & commissioning of water curtain nozzel 15mm dia nickel chrome plated brass, BSPT, K-factor as pe design consideration complete as required: |
| 384 | Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia. In white finish UL Listed or FM approved complete as required. |
| 385 | (Electrical work)A. INTERNAL WIRING & Fixture: |
| 386 | Supply & Recessed wiring to light point / first light of group control/ call bell point/ exhaust fan point /wall fan point with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVCconduit with 6 Amp, 250 V clip in type switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size ,with 1.5 sq.mm FRLSH PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge.Average length: 3 Mtr |
| 387 | Supply & Recessed wiring to secondary light pointlooped from primary light point with 1.5 Sq mm FRLSH PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metallic PVCconduitwith 1.5 Sq mm FRLSH PVC insulated single core multistrand copper conductor for running earth including3 plate ISI marked Ceiling rose with all accessories & connection as per direction of Engineer in charge. Average Length: 5Mtr |
| 388 | Supply & Recessed wiring to submain in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as required including all accesories and connection as per direction of Engineer in Charge. |
| 389 | Supply & Recessed wiring to submain in 2 x 4 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as required including all accesories and connection as per direction of Engineer in Charge. |
| 390 | Supply & Recessed wiring to submain in 2 x 6 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as required including all accesories and connection as per direction of Engineer in Charge. |
| 391 | Supplying and fixing of 150mm X 75mm X 60mm deepMetal Box along with accessories in recessed wiringincluding cutting the wall and making good the same in case of recessed conduit as required including all accesories and connection as per direction of Engineer in Charge. |
| 392 | Supply, Installation, Testing and Commissioning of ceiling fan 1200mm sweep,BEE5starrated,ceilingfanwith Brush Less Direct Current (BLDC) Motor with remote, class of insulation including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated single core multiatrand copper conductor etc. as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 393 | Supply & Recessed wiringfor 5 / 6 Amp socket outletwith6Amp, 250 V clip in type modular switch ISI markedmounted on G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection on same switch board as per direction of Engineer in Charge. |
| 394 | Supply & PointwiringforProjector/ Geyser / A.C socket outlet with 16A plug socketand 16Acontrol switch atnearest separate location including all accesories and connection as per direction of Engineer in Charge. |
| 395 | Supplying and fixing of 3 pin, 5 amp ceiling rose ISI marked on the existing junction box / wooden block including connection etc. including all accesories and connection as per direction of Engineer in Charge. |
| 396 | Supply delivery & installationof 45 watt 4500 K decorative energy efficient recess mounted 2\" X 2\" panel with white powdercoated CRCA housing and full mounted acrylic diffuser, flicker free low power consumption LED including all accesories and connection as per direction of Engineer in Charge. |
| 397 | Supply delivery & installation of 36 watt 4500 K recess mounted 2\" X 2\" panel with white powdercoated CRCA housing and full mounted acrylic diffuser, flicker free low power consumption LED including all accesories and connection as per direction of Engineer in Charge. |
| 398 | Supply delivery &installationof 24watt 4500 K recess mounted, round downlight with die cast alluminium housing, flicker free low power consumption LED and sleek backlit design suitable for low height ceiling including all accesories and connection as per direction of Engineer in Charge. |
| 399 | Supply delivery &installationof LED 20 watt 4500 K deep recess mounted COB based round , fixed downlight with die cast alluminium housing and anodized reflector , 52 degree beam angle including all accesories and connection as per direction of Engineer in Charge. |
| 400 | Supply, delivery & installationof 24W/meter LED linear profile confirming AL. housing with acrylic cover and non-dimmable LED driver. Colour Temp. should be 6000k. With CRI>90 and emitting angle 120 degree including all accesories and connection as per direction of Engineer in Charge. |
| 401 | Supply delivery and and installation of LED 33 w 4500 k recess mounted 1X4 panel with white powder coated CRCAhousing and full mounted acrylic difuser including all accesories and connection as per direction of Engineer in Charge. |
| 402 | Supply delivery & installationof LED 12 watt 4500 K surface mounted, round downlight with die cast alluminium housing and sleek backlit design suitable for low height ceiling including all accesories and connection as per direction of Engineer in Charge. |
| 403 | Supply, Installation, Testing and Commissioning of Minimum 8 Watt LED Bollard Light luminary fitting (As per the GTP attached in the Agreement) with base concreting of Bollard (As per the Foundation drawing attached in the Agreement) including all accessories and connection as per direction of Engineer in Charge. Similar to Make-K-LiTE Sleek Vera Bollard; Model-KL 5568. |
| 404 | Supply, delivery and installation of pressure diecast alluminium housing, 25 - 30 watt LED up down light conforming IP 65/66 , CCT 3000K. This item must have the high quality toughened glass cover including all accesories and connection as per direction of Engineer in Charge. |
| 405 | Supply, delivery and installation of 36w, 4 Ft long linear wall washer with IP 66 & colour temparature 3000k. This item also includes supply of IP 66 LED Driver including all accesories and connection as per direction of Engineer in Charge. |
| 406 | Supply, delivery and installation of 24V , IP 66 LED stip conforming 12 w/m & CCT 3000k. This item also includes supply & fixing IP 65/66/67 LED Driver. (1 UNIT =5 mtr LED strip + 1no Driver) including all accesories and connection as per direction of Engineer in Charge. |
| 407 | Supply, Installation, testing and commissioning of exhaust fan of 230 mm sweep 900 rpm in the existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etcas required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 408 | Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (a) 12 way Enclosure upto 200 Amp Schneider including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 409 | Supplying and fixing outdoor type 1 row 6 Module TPN MCB Distribution board for MCB incomer with IP-65/66 protection, on angle iron frame on wall & mending goodthe damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 410 | Supply and fixing of 4 pole MCCB 200 A, 25 KA breaking capacity in existing cubicle panel board including drilling holes in cubcle panel, making connections, etc. as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 411 | Supply and fixing of 4 way(4+12), Double door three pole and neutral, sheet steel, MCB distribution, 415 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required ( But with out MCB/ RCCB/ Isolator) including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 412 | Supply and fixing of 6 way(4+18), Double door three pole and neutral, sheet steel, MCB distribution, 415 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required ( But with out MCB/ RCCB/ Isolator) including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 413 | Supply and fixing of 8 way (4+24), Double door three pole and neutral, sheet steel, MCB distribution, 415 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required ( But with out MCB/ RCCB/ Isolator) including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 414 | Supplying and fixing Single pole 5A to 32A\"s rating,240/415votls,10kA,\"\"C\"\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as reuired including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 415 | Supplying and fixing 40 Amp TP,240/415votls,10kA,\"\"C\"\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as reuired including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 416 | Supplying and fixing 63 Amp TP,240/415votls,10kA,\"\"C\"\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as reuired including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 417 | Supplying and fixing 63 Amp TPN,240/415votls,10kA,\"\"C\"\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as reuired including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 418 | Supplying and fixing 16 Amp TPN,240/415votls,10kA,\"\"C\"\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as reuired including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 419 | Supply and fixing of 40 Amp four pole 415 V isolator in the existing MCB DB ISI marked complete with connection testing and commissioning etc. as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 420 | Supply and fixing of 63 Amp four pole 415 V isolator in the existing MCB DB ISI marked complete with connection testing and commissioning etc. as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 421 | Supplying and fixing 30A,415volts, TPN industrial type, socket outlet, with 4 pole and earth, matal enclosed plug top alongwith 30A \"\"C\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, teasting and commissioning etc. as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 422 | Supplying and installation following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as requied. 450mm width X 50mm depth X 2.0 mm thickness including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 423 | Supplyof3.5 C x 150 sq.mm Al aluminium, PVC Sheathed, XLPE insulated armoured power cable of 1.1 KV gradeincluding all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 424 | Supplyof3.5 C x 95 sq.mm Al aluminium, PVC Sheathed, XLPE insulated armoured power cable of 1.1 KV gradeincluding all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 425 | Supplyof3.5 C x 185 sq.mm Al aluminium, PVC Sheathed, XLPE insulated armoured power cable of 1.1 KV gradeincluding all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 426 | Supplyof4 C x 16 sq.mm Al aluminium, PVC Sheathed, XLPE insulated armoured power cable of 1.1 KV gradeincluding all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 427 | Supplyof4 C x 16 sq.mm copper , PVC Sheathed, XLPE insulated armoured power cable of 1.1 KV gradeincluding all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 428 | Supplyof3 C x 4 sq.mm copper, PVC Sheathed, XLPE insulated armoured power cable of 1.1 KV gradeincluding all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 429 | Supplyof4 C x 4 sq.mm copper, PVC Sheathed, XLPE insulated armoured power cable of 1.1 KV gradeincluding all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 430 | Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size excedding 25 sq.mm but not exceeding 120 sq.mm direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc. as required. |
| 431 | Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of 185 sq.mm 3.5 C size on cable tray as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 432 | Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of 95 sq.mm 3.5 C size on cable tray as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 433 | Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of 150 Sq.mm 3.5 C size on cable tray as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 434 | Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of 16 Sq.mm 4 C size on cable tray as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 435 | Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of 4 Sq.mm 3Csize on cable tray as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 436 | Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of 4 Sq.mm 4 C size on cable tray as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 437 | Supplying and making end termination with brass compression gland and aluminum lugs for 3.5 X 95 sq.mm (45mm)of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 438 | Supplying and making end termination with brass compression gland and aluminum lugs for 4 X 16 sq.mm (50mm) of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 439 | Supplying and making end termination with brass compression gland and aluminum lugs for 3.5 X 185 sq.mm of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 440 | Supplying and making end termination with brass compression gland and aluminum lugs for 3.5 X 150 sq.mmof PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 441 | Supplying and making end termination with brass compression gland and aluminum lugs for 3.5 X 300 sq.mmof PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 442 | Supplying and making end termination with brass compression gland and aluminum lugs for 4 X 16 sq.mm (50mm)of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 443 | Supplying and making end termination with brass compression gland and aluminum lugs for 3C X 4 sq.mmof PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 444 | Supplying and making end termination with brass compression gland and aluminum lugs for 4C X 4 sq.mm of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 445 | Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for 3.5 X 95 sq.mm size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grsde as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 446 | Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for 4 X 16 sq.mm size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grsde as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 447 | Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for 3.5 X 150sq.mm size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grsde as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 448 | Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for 3C X 4 sq.mmsize of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grsde as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 449 | Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for 4C X 4 sq.mmsize of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grsde as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 450 | Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for 3.5 X 300 sq.mmsize of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grsde as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 451 | Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for 4 X16 sq.mm Cusize of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grsde as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 452 | Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for 3.5 X 185 sq.mmsize of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grsde as required including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 453 | B. LIGHTNING ARRESTETR :Supply and installation of ESE Air Terminal: External, wide area, active early streamer emission (ESE) type lightning arrestor made of robust 316L stainless steel. It should be self sustaining and in full compliance of the Protection Radius worked out as per Rolling sphere concept & test Standard stated in NFC 17-102 Appendix C. It should be capable of polarizing the tip with a voltage of 20 KV to 25 kV, synchronized with an approaching lightning and triggering a powerful upward streamer into the air, with average time gain of 60 microseconds earlier than naturally formed streamers. The lightning Arrestor must be indigenous made and adapted to Indian weather conditions. The lightning arrester must be CPRI tested in India for 40 KA apart from approval from International High voltage Laboratory for withstanding 100KA at 10/350 microsecond including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. (protection radius 79 Mtrs as per protection level I) |
| 454 | Supply and installation of Support Mast:support mast of robust gn, made with 40 mm dia Class C MS pipe duly galvanized with minimum 85 micron zinc coating, along with all accessories like clamps, saddles, Minimum 4 numbers of stay arrangementsholding arrangement to fix the mast to the building/structure at highest point such that the Air terminal is 5 meters above the tallest structureand concreting arrangements necessary for poles and stay wire including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 455 | Supply and installation od Down Conductor:50 x 3 mm GI strip connecting Air terminal to the earth pit including clamps, saddles, and necessary accessories including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 456 | Supply and fixing of chemical Earthing of with 3mtr long40mm dia chemical filled compound and GI earth electrodeincluding excavation of earth pit with highly conductive back filled chemical compund of 2 x25kg , brick work in cement mortar masonary workwith removable cover for Earth pit chamber ofsuitable size including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 457 | Supply and installation of flash counter : Flash counter to count the numbers of lighting strikes arrested by ESE lighting arrester including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 458 | C. UNDER FLOOR TRUNKING :Supply delivery and installation of 275 GSM, 25 mm height, 1.6 mm lid, 2.5 mtr length under floor trunking conforming 150 mm 2 compartment structure including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 459 | Supply delivery and installation of 275 GSM, 25 mm height, 1.6 mm lid, 75 mm length joint sleeves compartable for 150 mm 2 compartment under floor trunking including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 460 | Supply delivery and installation of top recess - 20 mm with metallic lid, height : 90-105 mm access outlet box of size 150 mm x 150 mm having 2 nos 6/6 amp socket, 2 nos 16 amp switch, 1 no RJ 45 socket, 1 no RJ 11 socket including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 461 | Supply delivery and installation of top recess - 8 mm with metallic lid, height : 55-70 mm crossover junction box of size 150 mm x 150 mm including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 462 | Supply delivery and installation of vertical access box of size 250 mm x 200 mm x 45 mm including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 463 | Supply delivery and installation of 8 module with AV/HDMI pop up box suitable for conference table including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 464 | Supply delivery and installation of 32 mm x 12.5 mm mini trunking (length 2 mtr.) suitable for under table wiring including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 465 | Supply delivery and installation of flat tee of size 32 mm x 12.5 mm suitable for mini trunking of same size including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 466 | Supply delivery and installation of flat angle of size 32 mm x 12.5 mm suitable for mini trunking of same size including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 467 | D. SUBSTATION , PANELS, POWER CABLE , EARTHING:Supply,installation, testing and commisioning of11KV CSS consisting of HT(RMU)- Manual, Non-Extensible RMU (RL) consisting of 1Nos isolator (R Module) for incoming and 1Nos VCB module (L) for Transformer protection , Transformer-800KVA CRT Dry Type Transformer (Ref IS 11171), LV-1250A 4Pole ACB- Quantity 1 No Scope Of Supply :a)RMU type 8DJH ST - Manual operated, Non extensible RMU -RL-1No per CSS b)11 kV/0.433 kV, Tansformer with Off Load Tap Changer with tapping range+5% to -5% in steps of 2.5%,Vector group: Dyn11, Insulation - Class - FNo Load Losses : 2200 W (Subject to IS tolerance)Load Losses : 9750 W (Subject to IS tolerance)Impedance: 5% (Subject to IS tolerance) c) Aluminimum Bus Bar , 1250A FP 50KA MDO ACB with Microprocessor release( Type:3WT/Eq) -1 No ,d) Degree of protection for enclosure: IP54 for HT & LT switchgear; IP23 for Trafo including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 468 | CUBICAL PANEL:-Main LT PANEL Comprising of :Supply, Installation, testing & commissioning of 415/ 240 Volt, 3-Phase and neutral, 50 Hz. A.C. sheet steel (14/SWG) enclosed floor/wall mounted cubicle type IP65 Distribution Board complete with multifunctional meter, Surge Protector (Type-1), Digital/ analog Ammeter, Voltmeter, selector switch, necessary CTs, Kit Kat fuses etc. in incommer &havingCU Bus suitable for 4 Bar, 630 Amp. indicating lamp in all 3 phases for both main supply & emergency supply etc. all accessories & powder coated painting.(a) Incoming - 1Nos.- 1250 Microprocessor based ACB 4P 36 KA (Breaking capacity 36KA) type[FromMAIN PANEL](b) Incoming - 1Nos.-1250 Microprocessor based ACB 4P 36 KA (Breaking capacity 36KA) type[From DG] (C) Incoming - 1Nos.- 1250A 4P ATS (D) Bus bar - 1 Nos.- 1600 Amp. al bus bar (E) Outgoing - 3 Nos.-200 Amp. 4P Electrical Adjustable thermal (Breaking capacity 36 KA) type MCCB including of all proper operating handle as per specification.(F) Outgoing - 2 Nos.- 250Amp. 4 Pole Electrical Adjustable thermal (Breaking capacity 36 KA) type MCCB including of all proper operating handle as per specification (G) Outgoing - 2 Nos.- 400Amp.adjustable thermal4 Pole 36KA MCCB.(H) Outgoing - 3Nos.- 63Amp.tm adjustable4 Pole 36KA MCCB. (I)Outgoing - 2 Nos.- 32 Amp. FP36 KA MCCB.including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 469 | CUBICAL PANEL:-AirconditionerPANEL Comprising of :Supply, Installation, testing & commissioning of 415/ 240 Volt, 3-Phase and neutral, 50 Hz. A.C. sheet steel (14/SWG) enclosed floor/wall mounted cubicle IP65 Distribution Board complete with multifunctional meter, Surge Protector (Type-1), Digital/ analog Ammeter, Voltmeter, selector switch, necessary CTs, Kit Kat fuses etc. in incommer &havingCU Bus suitable for 4 Bar, 630 Amp. indicating lamp in all 3 phases for both main supply & emergency supply etc. all accessories & powder coated painting.(a) Incoming - 1Nos.- 400 Amp. 4 Pole Thermo Magnetic (Breaking capacity 25KA) type MCCB including of all proper operating handle as per specification.(b) Bus bar - 1 Nos.- 630 Amp. (c) Outgoing - 13 Nos.-63 Amp. 4 Pole Electrical Adjustable thermal (Breaking capacity 25 KA) type MCCB including of all proper operating handle as per specification. (d) Outgoing:- 63Amp TPN MCB-2 Nos.(e) Outgoing:- 32Amp DP MCB-2 Nos including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 470 | Supply and fixing of chemical Earthing of with 3mtr long40mm dia chemical filled compound and GI earth electrodeincluding excavation of earth pit with highly conductive back filled chemical compund of 2 x25kg , brick work in cement mortar masonary workwith removable cover for Earth pit chamber ofsuitable size including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 471 | Supplying and laying 25 mm x 5 mm G.I earth strip ISI marked at 0.5 meter below grond level as strip earth electrode including soldering etc. as required including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 472 | Providing and fixing 25 mm x 5 mm Copper strip in 40 mm dia G.I. pipe from earth electrode as required including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 473 | Providing and fixing earth bus bar of 50mm X 5 mm copper strip on surface for connections etc. as required including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 474 | Supply and delivery of 1.1 KV grade stranded al. arcable & cu including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 475 | Supply and laying of 300 Sq.mm 3.5 C Alumunium armoured PVC seathed / XLPE power cable of 1.1 KV grade including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 476 | Laying of 300 sq.mm 3.5 C Aluminium armoured cable in ground including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 477 | Laying and fixing of one number300 sq.mm 3.5 C Aluminium Arm PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size on cable tray as required. |
| 478 | E. LIFT :Supply, delivery & installation of 13 passenger Machine Room LessLift having following specification: Assembled Product :Passenger Elevator Capacity : 13 Persons, 884 kg Speed :1.00 m/s Stops & Openings : 03 Stops, 03 Openings - Same side Floordesignations: G, 1 Type : Machine Room Less Machine type & Location : Permanent Synchronise (PMS) Gearless machine located in theshaft on top of the guiderails Control : Simplex Collective Selective Control Drive : ACVVVF Power supply : 415 volts, 3 phase,50Hz, AC Hoist way dimensions : 2250 mm wide x 1900mm deep Car travel : 5000 mtr Overhead : 4500mm Pit depth : 1600mm Car dimensions: 1600 mm wide x 1350mm deep x 2200mm high Door opening : 900mm wide x 2100mm high Car door : 2 panel automatic Center opening door Handrail : Round handrail in Stainless steel finish provided on rear wall of car Landingoperating panel : Individual landing operating panel for each elevator Features : ACVVVF closed loop drive, Alarm button in caroperating panel with battery back-up, Automatic operation for car fan, Adjustable door open time, Blower fan in car for ventilation,Braille Button in Car operating panel and Landing operating panel, Car call cancellation by double pressing floor button in caroperation panel, Door open and door close buttons in car operating panel, Door closing retries, Door nudging,Emergency light, Fullload by-pass, Full Length Infra-red screen for car door, Intercom, Motor overheat protection, Overload function with audio-visualindication in car operating panel, Phase failure and phase including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 479 | F. Smoke detector |
| 480 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the two loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230±5% V, 50 hz), 48 hrs back- up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories. The panel shall be compatible for IBMS system with open protocol BACnet/Modbus over IP complete as per specificationsincluding all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 481 | Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as requiredincluding all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 482 | Supplying , installation , testing & commissioning of addresable horn cum strobe complete as required including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 483 | Supplying , installation , testing & commissioning of addresable fire control module complete as required including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 484 | Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of cross linkable ethylene propylene rubber ( EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as requiredincluding all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 485 | Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as requiredincluding all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 486 | Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as requiredincluding all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 487 | Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 488 | Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as requiredincluding all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 489 | Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as requiredincluding all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 490 | Supplying, installation, testing & commissioning Speaker cable three pair , 2 core , 1.5 sqmm including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 491 | Supply , installation , testing and commissioning of Addressable Fault Isolator Key Features - DIN rail mounting option , surafce mounting option , plug in connector, Tri- colour LED status indiaction, address selector switches visible in two planes , Led status visible in in 2 planes, Approved to GEa GEI 1-082 and CEA GEI 1-084 with necessary fittings including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 492 | ELV SystemSupply, Delivery & Installation of 4MP IP IR AI Based Network Varifocal Bullet Camera_2.8mm-13mm, 30Mtr Range, Project Series camera with Video tampering, UL, CE, FCC certified IP68 including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 493 | Supply, Delivery & Installation of 4MP IP IR AI Based Network Varifocal Dome Camera_2.8mm-12mm, 30Mtr Range, Project Series camera with Video tampering, UL, CE, FCC certified IP68 including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 494 | Supply, Delivery & Installation of 32 ch Project Series NVR with 08 SATA 8 HDDs and capacity of each HDD upto 8TB, RS-232; RS-485, Front panel: 2 × USB 2.0; Rear panel: 2 × USB 3.0, Alarm I/O 16/8, 4 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface, Multiple network monitoring: Web viewer, CE, FCC, UL certified. including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 495 | Supply & Delivery & Installation of 6TB Surveillance Hard Disk for Multiple 32 Channel NVR including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 496 | Supply, Delivery & Installation of 1000 BASE-T TO 1000 BASE-T LX SINGLE MODE FO MEDIA CONVERTER including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 497 | Supply, Delivery & Installation of 4 PNT/ 56 Line EPABX Machine & 64 Line EPABX Machine cabinet including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 498 | Supply, Delivery & Installation of CLI main Phone with speaker receiver including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 499 | Supply, Delivery & Installation of Receiver for Room Extension including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 500 | Supply, Delivery & Installation of 24Port 1G SFP (16Port *1G SFP +8 Combo Port) +4*10G Uplink Layer 3 Switch with Dual Power Supply including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 501 | Supply, Delivery & Installations of 24Port 1G SFP with 4 Ports Uplink Layer 2 Switch, 1Gbps L2 Switch including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 502 | Supply, Delivery & Installations of 48Port 10/100/1000 POE+4SFP Switch 4 Copper up link including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 503 | Supply, Delivery & Fixing of 1.25 GB SFP Module including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 504 | Supply , Delivery& Installations of High-density 802.11ax indoor wireless access point, dual-radio dual-band, up to 575Mbps for 2.4G (2*2 MIMO), up to 2.4Gbps for 5G (4*4 MIMO), up to 6 spatial streams, wireless access rate up to 2.97Gbps per AP. Supports concurrent 802.11a/b/g/n/ac and 802.11ax, FAT/FIT & Cloud including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 505 | Supply , Delivery & Installationsof Next-Gen Wireless Controller, 6*1000Base-T ports, 2*1000BASE-T/1000BASE-X combo ports, 1500AP Management including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 506 | Supply, Delivery & Laying of SM OFC 6 Core Armoured including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 507 | Supply, Delivery & Installations of 24 port Rack Mount Fiber Optic Patch panel fully loaded including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 508 | Supply, Delivery & Installations of Fiber Patch Cord SM-LC Simples 2M including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 509 | Supply, Delivery & Fixing of of TJP including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 510 | Supply, Delivery & Fixing ofOFC Pigtail including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 511 | Supply, Delivery & Installations of CAT 6 UTP Patch Cable -2 Mtr including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 512 | Supply, Delivery & Installations of 42U Floor Mount 600* 800*2000 Network Rack with fan PDU, and other necessary accessories Loaded Rack including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 513 | Supply, Delivery & Installations of 9U Wall Mount 488*560*600 Network Rack with fan PDU, and other necessary accessories including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 514 | Supply, Delivery & Fixing of UTP CAT-6 Dual Face Plate, Socket, Back Box I/O with SMB one for RJ45 and Another for RJ11 including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 515 | Supply, Delivery & Laying of Rigid 25mm PVC Conduit including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 516 | Fixing and Jointing of OFC cable fibre by hiredSplicing machine including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 517 | Supply, Delivery & Installations of CAT-7 RJ-45 Connectors including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 518 | Supply, Delivery & Installation of power board PDU metal body 7 Socket including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 519 | Supply, Delivery & Installation of LIU Loaded including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 520 | Supply, Delivery & Fixing of weather proof camera mounting Box including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 521 | Supply, Delivery & Fixing of Krone Module for EPABX including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 522 | Supply, Delivery & Fixing of10/20/30/50 Pair DB Box for EPABX including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 523 | Supply & Delivery & Laying of 50 Pair Telephone cable including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 524 | Supply, Delivery & installations of 1 KVA offline UPS, Input 135V-300VAC, Output 230V+_ 9% -5 min back up including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 525 | Supply, Delivery & Installation of Commercial HDMI Cable 10 Mtrs including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 526 | Supply, Delivery & Installation & Fixing 55”- LF560T 55” inch LED Full HD Commercial Smart TV including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 527 | Supply & Delivery, Installations & Commissioning ofCore i7 12Generation Server with 16GB RAM and 24\" monitor including all accessories, labour cost, T&P etc complete work as per Direction of EIC. |
| 528 | HVAC |
| 529 | Supplyof Outdoor Unit of Nominal Capacity -22 HP modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling only, having all hermetically sealed inverter type Scroll Compressor(s), with motor having 6 pole, minimum two compressors, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. with refrigerant-cooled PCB for better performance complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 415V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. MS/GI powder coated stand with vibration isolation pads. The ODU shall have lownoisecondenserfans with external static pressure of the outdoor unit shall be more then75Patoavoidhotairrecirculation,auto addresssetting,autocheckfunctionfor connection error and complete with indoor and outdoor unitswith individual controller and withfittingsetc. The compressor motor pole should be more than 4 for enhanced energy savings. COP of refrigerant circuitsystem for all systems shallbe6.83 minimum at 50% load, at AHRI Condition in cooling mode.The Unit should have free phase technology so that unit can work in case of phase reversal also without tripping of units. Outdoor unit complete with scroll compressor, condenser & its controller as described below including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 530 | Supplyof Nominal Capacity -2 HPcapacity 4-way/ round flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with cordless remote , synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, drain pump,cassette grill, insulation, necessary supports, vibration isolation etc,suitable for operation on 230 V ± 10%, 50 Hz single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire. All indoor Units should have force shut option to connect with fire alarm adaptor, so that the unit automatically stops in case or fire. The cooling capacity of indoor unit will be at air inlet conditions of 27degree C DBTand 19 degree C WBT. All 4 louvers of the unit shall be independently adjustable for positiion as per user preference. . The cassette unit should be with PM2.5 filter housed in filter chamber for better Indoor Air Quality including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 531 | Supplyinstalation testing commissioning of Nominal Capacity -2.5 HPcapacity 4-way/ round flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with cordless remote , synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, drain pump,cassette grill, insulation, necessary supports, vibration isolation etc,suitable for operation on 230 V ± 10%, 50 Hz single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire. All indoor Units should have force shut option to connect with fire alarm adaptor, so that the unit automatically stops in case or fire. The cooling capacity of indoor unit will be at air inlet conditions of 27degree C DBTand 19 degree C WBT. All 4 louvers of the unit shall be independently adjustable for positiion as per user preference. . The cassette unit should be with PM2.5 filter housed in filter chamber for better Indoor Air Quality including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 532 | Supplyinstalation testing commissioning of Nominal Capacity -3.2HPcapacity 4-way/ round flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with cordless remote , synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, drain pump,cassette grill, insulation, necessary supports, vibration isolation etc,suitable for operation on 230 V ± 10%, 50 Hz single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire. All indoor Units should have force shut option to connect with fire alarm adaptor, so that the unit automatically stops in case or fire. The cooling capacity of indoor unit will be at air inlet conditions of 27degree C DBTand 19 degree C WBT. All 4 louvers of the unit shall be independently adjustable for positiion as per user preference. . The cassette unit should be with PM2.5 filter housed in filter chamber for better Indoor Air Quality including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 533 | Supplyinstalation testing commissioning of Nominal Capacity -3.8 HPcapacity 4-way/ round flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with cordless remote , synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, drain pump,cassette grill, insulation, necessary supports, vibration isolation etc,suitable for operation on 230 V ± 10%, 50 Hz single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire. All indoor Units should have force shut option to connect with fire alarm adaptor, so that the unit automatically stops in case or fire. The cooling capacity of indoor unit will be at air inlet conditions of 27degree C DBTand 19 degree C WBT. All 4 louvers of the unit shall be independently adjustable for positiion as per user preference. . The cassette unit should be with PM2.5 filter housed in filter chamber for better Indoor Air Quality including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 534 | Supplyinstalation testing commissioning of Nominal Capacity -5 HPcapacity 4-way/ round flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with cordless remote , synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, drain pump,cassette grill, insulation, necessary supports, vibration isolation etc,suitable for operation on 230 V ± 10%, 50 Hz single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire. All indoor Units should have force shut option to connect with fire alarm adaptor, so that the unit automatically stops in case or fire. The cooling capacity of indoor unit will be at air inlet conditions of 27degree C DBTand 19 degree C WBT. All 4 louvers of the unit shall be independently adjustable for positiion as per user preference. . The cassette unit should be with PM2.5 filter housed in filter chamber for better Indoor Air Quality including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 535 | Supplyinstalation testing commissioning of Nominal Capacity -5.6 HPcapacity 4-way/ round flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with cordless remote , synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, drain pump,cassette grill, insulation, necessary supports, vibration isolation etc,suitable for operation on 230 V ± 10%, 50 Hz single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire. All indoor Units should have force shut option to connect with fire alarm adaptor, so that the unit automatically stops in case or fire. The cooling capacity of indoor unit will be at air inlet conditions of 27degree C DBTand 19 degree C WBT. All 4 louvers of the unit shall be independently adjustable for positiion as per user preference. . The cassette unit should be with PM2.5 filter housed in filter chamber for better Indoor Air Quality including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 536 | Supplyinstalation testing commissioning of Nominal Capacity -10 HPcapacity 4-way/ round flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with cordless remote , synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, drain pump,cassette grill, insulation, necessary supports, vibration isolation etc,suitable for operation on 230 V ± 10%, 50 Hz single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire. All indoor Units should have force shut option to connect with fire alarm adaptor, so that the unit automatically stops in case or fire. The cooling capacity of indoor unit will be at air inlet conditions of 27degree C DBTand 19 degree C WBT. All 4 louvers of the unit shall be independently adjustable for positiion as per user preference. . The cassette unit should be with PM2.5 filter housed in filter chamber for better Indoor Air Quality, unit capacity shall be VRV Ductable of 10 HP Capacity including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 537 | Supply, installation of ODUY joints / Distribution joints including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 538 | Supply, installation ofIDU Y joints / Distribution joints including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 539 | Installation, testing and commissioning of the above VRV outdoor units with R410A refrigerant, controls, electricals, necessary accessories. Capacities of VRV- 314 HP Outdoor including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 540 | Installation, testing and commissioning of all above VRV indoor units with refrigerant, controls, electricals, necessary accessories etc including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 541 | Supply, installation, testing & commissioning of site fabricated GI duct of reqd sizes duly insulated with nitrile rubber insulation including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 542 | Supply, installation, testing & commissioning of grill for passing air complete as reqd including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 543 | Supply, installation, testing and commissioning of PVC pipe medium class (for drainage of water from IDU) with 6 mm thick Nitrile Rubber insulation including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 544 | Supply & Laying of Cu scheilded flexible communication cabling between ODU and IDU as per OEM Specification (VRV). Cable shall be laying through hard PVC conduit pipe including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 545 | Supply & Filling of First charge of Refrigerant R410a including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 546 | Supply,installation, testing and commissioning of 41.1 mm dia (OD) (Copper Hard drawn) Interconnectingrefrigerantpipe work with1.2 mm thickness (Suction/Liquid Linepipe with 19/13 mm thick insulation) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all piping including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 547 | Supply,installation, testing and commissioning of 38.1 mm dia (OD) (Copper Hard drawn) Interconnectingrefrigerantpipe work with1.2 mm thickness(Suction/Liquid Linepipe with 19/13 mm thick insulation) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all piping including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 548 | Supply,installation, testing and commissioning of 34.1 mm dia (OD) (Copper Hard drawn) Interconnectingrefrigerantpipe work with1.2 mm thickness(Suction/Liquid Linepipe with 19/13 mm thick insulation) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all piping including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 549 | Supply,installation, testing and commissioning of 31.8 mm dia (OD) (Copper Hard drawn) Interconnectingrefrigerantpipe work with 1.2 mm thickness (Suction/Liquid Linepipe with 19/13 mm thick insulation) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all piping including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 550 | Supply,installation, testing and commissioning of 28.58 mm dia (OD) (Copper Hard drawn) Interconnectingrefrigerantpipe work with1.2 mm thickness(Suction/Liquid Linepipe with 19/13 mm thick insulation) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all piping including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 551 | Supply,installation, testing and commissioning of 25.4 mm dia (OD) (Copper Hard drawn) Interconnectingrefrigerantpipe work with1.2 mm thickness(Suction/Liquid Linepipe with 19/13 mm thick insulation) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all piping including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 552 | Supply,installation, testing and commissioning of 22.2 mm dia (OD) (Copper Hard drawn) Interconnectingrefrigerantpipe work with1.2 mm thickness (Suction/Liquid Linepipe with 19/13 mm thick insulation) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all piping including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 553 | Supply,installation, testing and commissioning of 19 mm dia (OD) (Copper Hard drawn) Interconnectingrefrigerantpipe work with1.2 mm thickness(Suction/Liquid Linepipe with 19/13 mm thick insulation) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all piping including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 554 | Supply,installation, testing and commissioning of 15.86 mm dia (OD) (Copper Soft drawn) Interconnectingrefrigerantpipe work with1.2 mm thickness(Suction/Liquid Linepipe with 19/13 mm thick insulation) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all piping including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 555 | Supply,installation, testing and commissioning of 12.7 mm dia (OD) (Copper Soft drawn) Interconnectingrefrigerantpipe work with1.2 mm thickness(Suction/Liquid Linepipe with 19/13 mm thick insulation) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all piping including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 556 | Supply,installation, testing and commissioning of 9.5 mm dia (OD) (Copper Soft drawn) Interconnectingrefrigerantpipe work with1.2 mm thickness(Suction/Liquid Linepipe with 19/13 mm thick insulation) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all piping including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
| 557 | Supply,installation, testing and commissioning of 6.4 mm dia (OD) (Copper Soft drawn) Interconnectingrefrigerantpipe work with 1.2 mm thickness (Suction/Liquid Linepipe with 19/13 mm thick insulation) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all piping including all accessories, cost of labour, T&P etc complete the work as perDirection of Engineer-In-Charge. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy