Tender For Repair / Maintenance To Gi Sheet, Ac Sheet, Replacement Of Asbestos Sheet Into Cgi Sheet With Allied Works In Tech Area At Af Stn Manauri, manauri-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair / Maintenance To Gi Sheet, Ac Sheet, Replacement Of Asbestos Sheet Into Cgi Sheet With Allied Works In Tech Area At Af Stn Manauri. Submission Date for this Tender is 03-05-2024. Shed Construction Tenders in manauri Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43079370
Corrigendum : Tender For Repair / Maintenance To Gi Sheet, Ac Sheet, Replacement Of Asbestos Sheet Into Cgi Sheet With Allied Works In Tech Area At Af Stn Manauri
Open Tender
Indian
Uttar Pradesh
manauri
03-05-2024

Tender Details

Tender For Repair / Maintenance To Gi Sheet, Ac Sheet, Replacement Of Asbestos Sheet Into Cgi Sheet With Allied Works In Tech Area At Af Stn Manauri

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Apr-2024 corrigendum1 Date 26-04-2024
2 16-Apr-2024 corrigendum BOQ 26-04-2024
3 26-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-05-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 19800.0 /-
Tender Value
INR 9.90 Lakhs /-

BOQ Items

Name of Work: REPAIR / MAINT TO GI SHEET, AC SHEET, REPLACEMENT OF ASBESTOS SHEET INTO CGI SHEET WITH ALLIED WORKS IN TECH AREA AT AF STN MANAURI
Sl. No. Item Description
1Dismantling of AC (corrugated/semi corrugated) sheet/PGI/CGI in roof covering including ridges complete all as specified and directed.
2M&L for 6mm thick Asbestos cement corrugated/semi corrugated sheet in roofs, fixed with L/J type hook or cranked hook bolt and making good to disturb surface etc complete all as specified and directed.
3S&F old dismantled 6mm thick Asbestos cement corrugated/semi corrugated sheet in roofs, fixed with L/J type hook or cranked hook bolt and making good to disturb surface etc complete all as specified and directed.
4S&FAC Serrated ridge two pieces adjustable 6mm thick for corrugated or semi corrugated AC sheets fixed complete all as specified and directed.
5S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws and making good to disturb surface, complete all as specified and directed.
6S&F old dismantled Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet any thickness and colour as in roof covering/cladding to wall, fixed with self tapping screws and making good to disturb surface, complete all as specified and directed.
7S&F 6 to 8mm thick poly carbonate sheet of colour as approved by Engr-in-Charge in roof coverings incl ridges and fixed with necessary J/J hook, fasterners etc complete all as specified and directed.
8S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding/ridge/valley gutter in wall/roof, fixed with self tapping screws complete all as specified and directed.
9Repair of holes in galvalume sheets/AC sheets by filling with bitumen washer, metal putty, silicon gel, M-Seal and similar solutions/chemicals to avoid leakage through the roof sheets complete all as specified and directed.
10Dismantling wrought iron or mild steel work of any description complete all as specified and directed.
11M&L for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and directed. (Fe- 410W Grade-E-250 quality A).
12M&L in applying two coats of synthetic enamel paints over a coat of red oxideprimer on new steel surfaces over 10 cm width or girth including preparatinon of surfaces complete all as specified and directed.
13Dismantling timber in fillets, rails, posts, rafters, purlins, etc under 40 sq cm in section, in any position complete all as specified and directed.
14M&L 2nd class hard wood plain fillets square, rectangular or trangular in section , clean sawn se-cured with nails or brads area exc 3 and n.exc 13 sqcm. complete all as specified and directed.
15Dismantling timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed.
16M&L for Second class hard-wood in scantlings complete all as specified and directed.
17Dismantling wall and ceiling boards (fiber, pulp, insulation etc.) any thickness, including cover fillets etc complete all as specified and directed.
18M&L in ceiling 4mm thick non abestos cement plain building boards, fixed to timber frame work with screws etc and including two coat of white wash, complete all as specified and directed.
19M&L for PCC1:2:4 type B-0 using 12.5mm graded stone aggregate , as in copping and roof padding etc complete all as specified and directed.
20Demolition of brick work built in cement mortar including all quoions, arches pillar etc complete all as specified and directed.
21M&L brick work with sub class "B" old size bricks, straight or curved on plan exec 6m mean radius built in CM 1:6 complete all as specified and directed.
22M&L in repairs for providing gypsum board 12mm thick in ceiling fixed with screw as per manufacturers instructions (except grids) complete all as specified and directed.
23S&F in repairs for providing gypsum board 12mm thick in ceiling over and including anodised aluminium snap grid frame work for false ceiling, size of grid 605 x 605mm complete all as specified and as directed
24S&F in repairs grid false ceiling in GI system powder coated prelude main runner section 38 x 24 x 0.40mm, cross "T" 28 x 24 x 0.40mm, wall angle 24 x 24 x 0.40mm and including providing and fixing 4mm thick non asbestos fibre fire resistant cement building board/E-Board with all finishes size 595 x 595mm fixed in ceiling frame work with all necessary hanging washers, expansion holding fasteners etc for securing framework to ceiling wherever required complete all as specified and directed.
25S&F in repairs 4mm thick non asbestos fibre fire resistant cement building board/E-Board with all finishes size 595 x 595mm fixed in existing ceiling frame work with all necessary hanging washers, expansion holding fasteners etc for securing framework to ceiling wherever required complete all as specified and directed.
26M&L for preparation of ceiling surface and applying two coats of OBD over a coat of putty as required complete all as specified and directed.
27S&F in PVC (SWR) pipes, single socketed in any length with rubber rings 110mm dia and fixed to wall complete all as specified and directed.
28S&F in PVC (SWR) pipes, single socketed in any length with rubber rings 75mm dia and fixed to wall complete all as specified and directed.
29Demolition of brick work built in cement mortar including all quoions, arches pillar etc complete all as specified and directed.
30M&L brick work with sub class "B" old size bricks, straight or curved on plan exec 6m mean radius built in CM 1:6 complete all as specified and directed.
31Taking down cement plaster on brick/stone surface of wall built in cement mortar including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
32M&L for rendering 15 mm thick on fair face of brick walls or concrete surface in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed.
33M&L for preparation of new plastered surfaces of wall and applying two coats of cement base paint complete all as specified and directed.
34Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ. (ii) Make of material shall be as per mentioned in Particular specifications or Appendix "B" to Particular specifications as approved by AGE (I) AF manauri
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail