}

Tender For Special Repair To Roof Treatment Including Connected Works Of Building No. Xxxiii/1 And 2 And Building No. Xiii, Provision Of 50 X Two Wheeler Parking Shed And Pathway At Certain Area Under Ge Chennai, chennai-Tamil Nadu

Military Engineer Services-MES has published Tender For Special Repair To Roof Treatment Including Connected Works Of Building No. Xxxiii/1 And 2 And Building No. Xiii, Provision Of 50 X Two Wheeler Parking Shed And Pathway At Certain Area Under Ge Chennai. Submission Date for this Tender is 04-05-2024. Building Work Tenders in chennai Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

43078924
Corrigendum : Tender For Special Repair To Roof Treatment Including Connected Works Of Building No. Xxxiii/1 And 2 And Building No. Xiii, Provision Of 50 X Two Wheeler Parking Shed And Pathway At Certain Area Under Ge Chennai
Open Tender
Indian
Tamil Nadu
chennai
04-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Special Repair To Roof Treatment Including Connected Works Of Building No. Xxxiii/1 And 2 And Building No. Xiii, Provision Of 50 X Two Wheeler Parking Shed And Pathway At Certain Area Under Ge Chennai

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 06-Apr-2024 BOQ BOQ 20-04-2024
2 10-Apr-2024 Date Date 27-04-2024
3 17-Apr-2024 BOQ corrigendum BOQ 27-04-2024
4 23-Apr-2024 Other Corrigendum Other 27-04-2024
5 27-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 04-05-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 95300.0 /-
Tender Value
INR 47.65 Lakhs /-

Attachment

FileName File Description File Size
12c8d5b3-e0a8-4de4-9727-a156c5cc3e14.html Tender Notice 0 KB
BOQ_726123.xls Tender Document 0 KB
Tender8730.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: SPECIAL REPAIR TO ROOF TREATMENT INCLUDING CONNECTED WORKS OF BUILDING NO. XXXIII/1&2 AND BUILDING NO. XIII, PROVN OF 50 X TWO WHEELER PARKING SHED& PATHWAY AT CERTAIN AREA UNDER GE CHENNAI
Sl. No. Item Description
1Dismantling timber scantlings 40sq. cm and over in section, in anypositionun framed work including filling the voids of embedded portion of wood into thewallwith PCC 1: 2 : 4 (20 MM graded aggregates )including finished the surface smooth and even all as specified and directed
2Demolition in portion orderedmadras terrace roofs in lime mortar,Reinforced brickwork in suspended slabs, beams, lintels etc. in cement mortar or cement concreteincluding 15 mm thick rendering the junction of wall and madras terrace roof in CM 1 : 3 all as specified and directed
3Dismantling wrought iron or mild steel work of any description not otherwise provided for
4Cutting holes into orthrough brick wallsbuilt in cement mortar and 15 mm thick rendering to the surface of cuttingin cementmortar 1:3 as required superficial areaExc 0.10 sq.m. but n exc 0.20 sq.m.
5Cutting chases, pinning in throudh brick walls built in lime mortar, makinggood to facings where required andpointing in cement mortar 1:3 toends or edges of landings, steps,cills, sunshades, shelves, lintels,slabs etc.;and cutting chases for concealedwater tubing or concealed conduitwiring, etc. and making good girth of,cutting is80cmall as specified and directed
6M&L for form work to sides and soffits of floor or roof beams beam haunchings, girders, bressummers lintels etc rough finished surfaces of concrete.
7M&L for form work to sides ofpillars ,posts,struts,piers,columns and stanctions for rough finished surfaces of concrete.
8M &Lform work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (Horizontal or Sloping) for fair finished surfaces
9M/L 10mm dia and over TMT bars as in reinforecment cut to length bent to shape required including cranking hooking ends and binding with mild steel wire( annealed) not less than 0.9 mm dia (or) securing with clips all as specified and as directed
10-ditto- but 5 mm dia and over upto and including 10mm dia in stirrups, spacers and binders quality conforming to Fe-410
11M & Lfor reinforced cement concrete M-30(Design mix ) using 20mm graded agggregate in slabs supported on walls beams and columns in floors roofs, landings, balconies canopies deck slabs and in shelves and the like
12M & Lfor reinforced cement concrete M-30(Design mix ) using 20mm graded agggregate in beams, cantilevers, bressummers, litels over 1.5m span.
13M & Lfor reinforced cement concrete M-30(Design mix ) using 20mm graded agggregate incolumns,pillars,piers,posts and struts .
14Roof trusses ( framed) trussed purlin, crane gantries, rails and fastenings and heavy bracket ( Bem, tee, angle, channel or flat sections including distance pieces, cleats etc confirming to confirming to
15M&L for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting platesconfirming toFe 410 - W (Grade E-250 Quality -A )
16M&L for Plates (plain or chequered)channels, square cut or notched(ordinary and counter sunk)forming holes, without anyattachmentconfirming to Fe 410 - W (Grade E-250 Quality -A )
17S&F pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
18S&F pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
19S&F Mild steel screw bolts16 to 20 mm dia (machine made) withhexagonal or squareheads at one end andscrewed the other, orscrewed both ends, eachscrewed end to be fittedwith washers and onehexagonal or squarenut,exc22. 5cm but not exc 30 cm long
20M&Lfor providing husk chushioning 450 mm thick to first floor for protection of flooring during demolition of roof and removal from the site after work completion all as specified and directed
21M&L for10mm thick cement plaster in CM 1:4 mixed with WPC @ 200 ml per bag, including finished the surfaces smooth and even without using extra cementall as per manufacturer instructions ( Note: Water proofing compound will be paid under measured seperately)
22M&L for10mm thick cement plaster in CM 1:3on walls including finished the surfaces smooth and even without using extra cementmixed with WPC @ 200 ml per bag,all as per manufacturer instructions ( Note: Water proofing compound will be paid under measured seperately)
23Supply only Liquid water proofing compoud
24Cleaning and preparation of newly plasteres roof surfaces and applying the water proofing treatment as under. (a)Applying 1st course of bituminious (oil based) primer confirming to IS-3384 @ 0.4 lit/sqm over the screed bed. (b)Applying 2nd course of a coat of binding material with blown type bitumen of grade 85/25 heating to working temperature of 180 0 C and applied @ 1.2 kg/sqm. (c) Applying 3rd course of APP (Atactic polypropylene) based polymeric membrane minimum weighing 3.6 kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric (wt not less than 150 gms/sqm) laid with 75 mm side overlapand 100 mm overlap by forced / torch application as per manufactures instructions. (d) Applying 4th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to working temperature of 180 degree C and applied @ 1.2 kg/sqm over APP membrane,(e)Applying 5th course of a one coat of solar reflective aluminium paint @ 0.10 Litre/Sqm on roof surfaces complete all as specified and directed.
25Cleaning and preparation of newly plastered wall surfaces and applying the water proofing treatment as under.(a)Applying 1st course of bituminious (oil based) primer confirming to IS-3384 @ 0.4 lit/sqm over the screed bed. (b)Applying 2nd course of a coat of binding material with blown type bitumen of grade 85/25 heating to working temperature of 180 0 C and applied @ 1.2 kg/sqm. (c) Applying 3rd course of APP (Atactic polypropylene) based polymeric membrane minimum weighing 3.6 kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric (wt not less than 150 gms/sqm) laid with 75 mm side overlapand 100 mm overlap by forced / torch application as per manufactures instructions. (d) Applying 4th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to working temperature of 180 degree C and applied @ 1.2 kg/sqm over APP membrane,(e)Applying 5th course of a one coat of solar reflective aluminium paint @ 0.10 Litre/Sqm on wall surfaces complete all as specified and directed.
26M/L providing reinforced cement concrete 1:2:4, type B1 (using 20 mm graded aggregate) as in cills, steps, bands, copings, bed plates ,eves filling etcincluding necessary form work, all as specified and as directed
27S&F Rotational moulded polyethylene water tank (cylindrical vertical closed top) hoisted and fixed in position capacity of tank 1000 ltrs with threaded typeincluding dismantling of existing tank of any descriptionand S&F 20 mm ball PTMT Ball valve high pressure with exposy coated aluminum rod and high density plastic ball screwed for iron pipe.
28Taking up or down 15 mm bore steel tubing and connections and S&F for 15mm GI Tubes, "medium" grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors all as directed.
29Taking up or down 20 mm bore steel tubing and connections and S&F for 20mm GI Tubes, "medium" grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors all as directed.
30Taking up or down 25 mm bore steel tubing and connections and S&F for 20mm GI Tubes, "medium" grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors all as directed.
31M & L Gun metal globe or gate valve with iron wheel head screwd both ends for iron pipe and fixed for 25 mm dia bore pipes fixed in repairs
32M & L Gun metal globe or gate valve with iron wheel head screwd both ends for iron pipe and fixed for 20 mm dia bore pipes fixed in repairs
33Demolitionin portion as orderd of brick or stone masonry , built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed.
34Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed.
35M & L for Brickworkwith fly ash bricks , straight or curved on plan exc 6m mean radius built in CM 1:6.
36S&F of PVC (SWR) pipes as in spout incl taking down of old pipes complete all as specified and directed.
37M&L for cutting of trees of girth 300mm and removing of penetrated roots upto 1.80m depth/lengh on wall or roof surfaces including necessary brick work , plaster and filling the crack with PCC 1:1.5:3(20 mm graded stone aggragate)complete all as specified and directed.Note :The unit rate quoted shall be deemed to include the cost of scaffoloding/ staging etc.,
38Cutting down vegetation growths like plants/ trees of girth n. exc 15cm from roof tops/ sides, external walls of bldgs, chajjas, wall juctions at junction of rain water/ CI waste water pipe junctions including removal of roots and taking out carefully possible quality of concrete in roofs embedded in walls/ slab surfaces making good affected locations and applying TUFALO chemical (herbalmedicine or Glyphosate Herbicide/equivalent) to arrest further growth and making good the distrubed surfaces with PCC (1:2:4) type B-1 or CM 1:2all as specified and directed by the Engr-in-Charge. Note :The unit rate quoted shall be deemed to include the cost of scaffoloding/ staging etc.,
39Taking down cement or cement limeplaster on brick or stone walls, etc. including raking outjoints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
40M&L for rendering 10mm thick in CM 1:3 on ceilingarea not exceeding in patches not exceeding 5.00 sqm, finished even and smooth without using extra cement all as specified and directed.
41M&L Rendering 15mm thick in CM 1:6 onfair face of brick work suraces finished even and smooth without using extra cement.
42M&L for rendering 15mm thick on fair faces of brick work in two layers, first layer 10mm thick in CM 1:6and second finishing coat 5mm thick in CM 1:4 mixed with water proofing compound as per manufacturers instructions and finished even and fair on external surfaces.
43M&L for preparation of newly plastered wall surfaces of walland applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and as directed.
44Material and labour for applying two or more coats of 100% premium acrylic mulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces complete including preparation of newly plastered surfaces of walls all as specified and as directed by the Engineer-in-Charge.Make: APEX ofAsian or equivalent of shalimar / Nerolac/ Berger.
45Forming square grooves in plaster n exc 12mm deep and n exc 15mm on face complete all as specified and directed.
46Complete removal of existing treatment & Material and labour for applying two or more coats of 100% premium acrylic mulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces complete including preparation of old plastered surfaces of walls all as specified and as directed by the Engineer-in-Charge.Make: APEX ofAsian or equivalent of shalimar / Nerolac/ Berger.
47M & L for applying two coat of white wash as in ceiling incl preparation of oldplastered surfaces all as specified and as directed.
48M & L for applying three coat of white wash as in ceiling incl preparation of new plastered surfaces all as specified and as directed.
49M & L for complete removal of existing treatment on wall surfaces and washing, rubbing down and applying two coats of oilbound distemper oyer a coat of alkali resistant primer and1 mm thickputty on old surfaces of wall all as specified and as directed.
50M & L two coat of synthetic enamel paint on old steel surfaces including preparation ofsurfaces of any description , over 10cm width or girth not other wise described.
51M & L for preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coat of Synthetic enamel paint.
52Demolition of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets
53M & L for galvanised powder coated snap grid framework of size 605 x 605mm for false ceiling all as specified including vinyl laminated MPL gypsum panels ( GYPTECH) 9mm thick of size 60 x 60 cm fixing withstapples on snap grid by means of GI wires not less than 4mmdia hooks and raw plug etc centre of amke. GYPTECH ?ARMSTRONG or equivalent all as directed by Engr-in-Charge
54Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings
55Cutting chases, pinning inbrick /concrete. making good to facings where required andpointing in cement mortar 1:3 toends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; andcutting chases for concealed watertubing or concealed conduit wiring,etc., and making good, cutting , exc 10 cm but not exc 20 cmgirth
56Cutting holes into orthrough brick wallsbuilt in cement mortar andmaking good in cementmortar 1:3 or cementconcrete 1:2:4 type B-l as required superficial areaExc 400 sq. cm but n exc 0.10 sq.m.
57S&F for Plate girder or single stanchions,built up of one beam or channel section with flange plates, caps,bases. splices, angle brackets,cleats and other connectionsconfirming to Fe 410-W(Gde-E- 250)quality-B
58Applying two coats of synthetic enamelled paint over a coat of red oxide on steel or iron surfacebased materials of any description , not other wise described over 10 cm width or girth including preparation of new surfaces.
59M&L for Applying evenly a tack coat of in dustrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces
60Demolition of cement concrete of any description in any position not otherwise specially provided for including existing roof treatment any typeall specified and directed by Engr-in-Charge
61M&L for10mm thick cement plaster/screed in CM 1:4 mixed with WPC @ 200 ml per bag, including finished the surfaces smooth and even without using extra cementall as per manufacturer instructions ( Note: Water proofing compound will be paid under measured seperately)
62M&L for10mm thick cement plaster in CM 1:3on walls including finished the surfaces smooth and even without using extra cementmixed with WPC @ 200 ml per bag,all as per manufacturer instructions ( Note: Water proofing compound will be paid under measured seperately)
63Supply only Liquid water proofing compoud
64M & L for plain cement concrete in roof kerbs or mud stops, rounded or chamfered on edges as roof padding type B0, 1:2:4 (12.5mm graded aggregate) finished fair and even over concrete surface on roof top, and finished even and smooth complete all as specifie and directed.
65Cleaning and preparation of newly plasteres roof surfaces and applying the water proofing treatment as under. (a)Applying 1st course of bituminious (oil based) primer confirming to IS-3384 @ 0.4 lit/sqm over the screed bed. (b)Applying 2nd course of a coat of binding material with blown type bitumen of grade 85/25 heating to working temperature of 180 0 C and applied @ 1.2 kg/sqm. (c) Applying 3rd course of APP (Atactic polypropylene) based polymeric membrane minimum weighing 3.6 kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric (wt not less than 150 gms/sqm) laid with 75 mm side overlapand 100 mm overlap by forced / torch application as per manufactures instructions. (d) Applying 4th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to working temperature of 180 degree C and applied @ 1.2 kg/sqm over APP membrane, (e)Applying 5th course of a one coat of solar reflective aluminium paint @ 0.10 Litre/Sqm on roof surfaces complete all as specified and directed.
66Cleaning and preparation of newly plastered wall surfaces and applying the water proofing treatment as under.(a)Applying 1st course of bituminious (oil based) primer confirming to IS-3384 @ 0.4 lit/sqm over the screed bed. (b)Applying 2nd course of a coat of binding material with blown type bitumen of grade 85/25 heating to working temperature of 180 0 C and applied @ 1.2 kg/sqm. (c) Applying 3rd course of APP (Atactic polypropylene) based polymeric membrane minimum weighing 3.6 kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric (wt not less than 150 gms/sqm) laid with 75 mm side overlapand 100 mm overlap by forced / torch application as per manufactures instructions. (d) Applying 4th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to working temperature of 180 degree C and applied @ 1.2 kg/sqm over APP membrane, (e)Applying 5th course of a one coat of solar reflective aluminium paint @ 0.10 Litre/Sqm on wall surfaces complete all as specified and directed.
67M/L providing reinforced cement concrete 1:2:4, type B1 (using 20 mm graded aggregate) as in cills, steps, bands, copings, bed plates ,eves filling etcincluding necessary form work, all as specified and as directed
68S&F Rotational moulded polyethylene water tank (cylindrical vertical closed top) hoisted and fixed in position capacity of tank 500 ltrs with threaded typeincluding dismantling of existing tank of any descriptionand S&F 20 mm ball PTMT Ball valve high pressure with exposy coated aluminum rod and high density plastic ball screwed for iron pipe.
69Taking up or down 15 mm bore steel tubing and connections and S&F for 15mm GI Tubes, "medium" grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors all as directed.
70Taking up or down 20 mm bore steel tubing and connections and S&F for 20mm GI Tubes, "medium" grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors all as directed.
71Taking up or down 25 mm bore steel tubing and connections and S&F for 20mm GI Tubes, "medium" grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors all as directed.
72M & L Gun metal globe or gate valve with iron wheel head screwd both ends for iron pipe and fixed for 25 mm dia bore pipes fixed in repairs
73M & L Gun metal globe or gate valve with iron wheel head screwd both ends for iron pipe and fixed for 20 mm dia bore pipes fixed in repairs
74Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed.
75M & L for Brickworkwith fly ash bricks , straight or curved on plan exc 6m mean radius built in CM 1:6.
76S&F of110 mm bore PVC (SWR) pipes as in spout incl taking down of old pipes complete all as specified and directed.
77Taking down cement or cement limeplaster on brick or stone walls, etc. including raking outjoints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
78M&L for rendering 10mm thick in CM 1:3 on ceilingareain patches not exceeding 5.00 sqm, finished even and smooth without using extra cement all as specified and directed.
79M&L Rendering 15mm thick in CM 1:6 onfair face of brick work suraces finished even and smooth without using extra cement.
80M&L for rendering 15mm thick on fair faces of brick work in two layers, first layer 10mm thick in CM 1:6and second finishing coat 5mm thick in CM 1:4 mixed with water proofing compound as per manufacturers instructions and finished even and fair on external surfaces.
81M&L for preparation of newly plastered wall surfaces of walland applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and as directed.
82Material and labour for applying two or more coats of 100% premium acrylic mulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces complete including preparation of newly plastered surfaces of walls all as specified and as directed by the Engineer-in-Charge.Make: APEX ofAsian or equivalent of shalimar / Nerolac/ Berger.
83M & L for applying three coat of white wash as in ceiling incl preparation of new plastered surfaces all as specified and as directed.
84Cutting chases, pinning inbrick /concrete. making good to facings where required andpointing in cement mortar 1:3 toends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; andcutting chases for concealed watertubing or concealed conduit wiring,etc., and making good, cutting , exc 10 cm but not exc 20 cmgirth
85Surface excavation n.exc 30cm deep & averaging 15cm deep and getting out in soft / loose soil.
86M&L providing 75mm thick PCC (1:5:10) Type E2 (using 40mm graded stone aggregate) as sub base complete
87Sand filling under floors or in foundations incl watering and consolidation
88M&L for machine pressed precast concrete interlocking paver block any shape and size onforming to IS 15658-2006 of 60mm thickness M-35 Grade with grey cement and no pigment complete all as specified and directed
89M&L for PCC 1:2:4 type B1 (using 20mm graded aggregate) in copings, kerbs, channels, water through and the like including weathering, slightly rounded or chamfered angles and throating etc complete all as specified and asdirected.
90M & L for removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exc 1.50M above the starting points
91M&L Rendering 15mm thick in CM 1:6 onfair face of brick work suraces finished even and smooth without using extra cement.
92M&L for preparation of newly plastered surfaces and applying three coats of white wash on ceiling/ facia complete all as specified and directed
93M & L for Brickworkwith fly ash bricks , straight or curved on plan exc 6m mean radius built in CM 1:6.
94S&F pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
95S&F pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
96Roof trusses ( framed) trussed purlin, crane gantries, rails and fastenings and heavy bracket ( Bem, tee, angle, channel or flat sections including distance pieces, cleats etc
97Applying two coats of synthetic enamelled paint over a coat of red oxide on steel or iron surfacebased materials of any description , not other wise described over 10 cm width or girth including preparation of new surfaces.
98M&L for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting platesconfirming toFe 410 - W (Grade E-250 Quality -A )
99Cutting chases, pinning inbrick /concrete. making good to facings where required andpointing in cement mortar 1:3 toends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; andcutting chases for concealed watertubing or concealed conduit wiring,etc., and making good, cutting , exc 10 cm but not exc 20 cmgirth
100M&L f\or plain cement concrete in lintels upto 1.5m clearspan, cills, steps; seismicand other similar bands,plinth courses, string courses,lacing courses, parapets andrailings upto 60 cm in height,copings, kneelers, apex stones,bed plates, kerbs not providedfor in Item 04028, watertroughs and the like includingweathering, slightly rounded or chamfered angles and throating, as directed including necessary form work
101Cutting holes into or through brick walls but in brick walls superficial area n.exc 150sqcm built, in cement mortar or cement lime mortar and stone walls built in lime mortar or walls of lime concrete. and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required
102Excavating in post holes (orsimilar holes) each n exc 0.5cu. m, getting out, returning,filling in and ramming earthor broken rubble mixed withearth around, in layers notexceeding 25 cmsoft /loose soil
103M&L PCC Type B2 (1:2:4) using 40mm graded stone aggregates as in foundation, filling and mass concrete
104Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed.
105S & F110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joint fixed to walls including taking down old one.
106S & F 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joint laid in trenches or in flors including taking down old one.
107S&F (SWR) Bends of any radiusof 110 mm bore of pipe with oval access door
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail