| 1 | Supply and erecting shuttering including necessary supports for plane surfaces such as RCC column, footing, plinth beam, stair case etc., in all floors using mild steel sheets of 90cm X 60cm and 10 gauge stiffened with welded mild steel angle for boarding supported by casurina props at suitable intervals etc., completed complying with standard specification and as directed. Sl.No.122 |
| 2 | Supply and erecting centering for sides and soffits including supports and strutting upto 3.29m high for plane surfaces such as RCC slabs, Rectangular beems, Tee (or) ECC Beam, Lintel, Bed Block, Staircase waist and landing slabs landing beams, canopy etc., in all floor with all cross bracings using mild steel sheets of size 90cm X 60cm and BG 10 stiffened with welded mild steel angles of size 25mm X 25 X 3mm for boarding laid over country wood joinsts of size 10cm X 6.50 cm spaced at about 90cm C/C and supports by Causrina props of 10cm to 13cm dia spaced at 75cm C/C etc., completed as directed. Sl.No.123 |
| 3 | Supplying and erecting centering for sides soffits including supports and strutting upto 3.29m high for plain surface such as rectangular column top and bottom slabs of boxing, sill, slabs, sun shade etc., in all floors using mild steel slabs of sizes 90cm x 60cm and BG 10 stiffened with welded mild steel angles of size 25X25x3mm for boarding laid over country wood joists of size 10cm X 6.5cm spaced at about 90cm C/C and supported by casurina props of 10cm to 13cm dia spaced at 75cm C/C etc., complete as directed. Sl.No.123 C Part-II |
| 4 | Supply and fabrication of R.T.S. rods in various dia including cutting bending placing in position and tying etc. |
| 5 | Cement concrete 1:1.5:3 (one cement, one and a half sand and three aggregate) using 20mm gauge hard broken granite stone jelly for All RCC items of work excluding centering, shuttering, and cost of reinforcement grill but including curing finishing etc., complete and also including fixing fan clamps and fixtures in RCC works wherever necessary as directed by departmental officer etc., complete. |
| 6 | Fly ash Brick work in CM 1:5 (one cement & five sand) using size 9\"X4 3/8\"X 2 3/4\" including finishing, curing, etc., complete complying with standard specification |
| 7 | First Floor |
| 8 | Supply and fixing of mild steel door using all round \"L\" angle 25 X 25 X 6mm thick, cross bracing 20 X 6mm M.S.Flat with necessary locking arrangements including cost and conveyance etc., Size : 0.60 X 1.85 |
| 9 | Weathering course in concrete broken stone brick jelly 20mm size in pure slacked lime over RCC slab. The proporation being 32:12:5 for requuired slope and the thickness of roof as required and well beaten with wooden beaters etc., completed |
| 10 | Terrace flooring with one couse of pressed tiles of size 23 X 23 in cement mortar 1:3 mix with impermo oil 2% by weight of cement and pointed with same oiled mortar |
| 11 | plastering the exposed surface of RCC works in cement mortar 1:3 mix 10mm thick |
| 12 | Plastering with cement mortar 1:5 mix (one cement and five sand) 12mm thick |
| 13 | Paving the floor with Vitrified Floor Tiles of size 60 X 60cm of approved brand and colour Marbonite tiles in all floors base layer of cement mortar 1:3 (one cement and three sand) 20mm thick using first quality Marbonite tiles of size 60 X 60cm and point with colour cement neatly and fixed in position so as to make perfectly smooth and to alignment etc., complete complying with standard specification |
| 14 | Painting two emulsion paint two coats over a priming coat including through cleaning, scrapping, removal of dust and including necessary plaster of paris putty works wherever required etc., completed. |
| 15 | Painting new iron work for doors, windows, grills, weld mesh sceens etc., two coats etc complete |
| 16 | Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A FT switch and making good of the concealed portion with suitable colour for PVC concealed light / fan Point (for electronic regulator) (5 points per coil) |
| 17 | Wiring with 2 x 1.5 sq.mm. (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories in flush with wall with 150mm x 100mm x 75mm MS switch box with 3mm thick hylum sheet cover for 5A 3pin non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed plug point |
| 18 | Supply and fixing of single box type 4\"40W fluorescent fitting complete with copper choke and condensor with conduit pipe suspension from the ceiling with PVC unsheathed copper leads from terminals to the fitting with tube |
| 19 | Supply and run of 2 of 4 sq.mm. (56 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade insuitable heavy gauge MS conduit pipe concealed in wall and ceiling with continuous earth wire connection by 14 SWG TC wire and making good of the concealed portion wiith suitable colour |
| 20 | Supply and fixing of 20A DP plug and socket in sheet enclosure with 32A DP MCB in flush with wall with earth connection (For AC Plug) [Legrand (MDS) / Hager (L&T) Make] |
| 21 | Supply and fixing of 1200mm (48\") AC ceiling fan complete with stepped electronic 300W regulator with 1 meter down rod on the existing clamp |
| 22 | Supply and fixing MS steel hollow section pipes etc., complete |
| 23 | Supplying and fixing with Galvalume Colour Sheet of size 0.47mm thick including necessary bolt, nuts and bitumen washed etc., completed - 10 m2 |
| 24 | Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug. |
| 25 | UPVC WindowSpecification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to theshutter and it should not allow leakage of water even at most ranging storms and should have key lockableaction, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work |
| 26 | Supply and fixing of perforated chairs as per the direction of Dept. off., Etc complete |
| 27 | Supply UPVC Rack as per the direction of Dept. off., Etc complete |