Tender For Repair Of Roof, Chajja, Parapet And Connected Items In Pbor Md Accn In The Area Of Age B/R-Ii Under Ge (West) Delhi Cantt-10, delhi-Delhi

Military Engineer Services-MES has published Tender For Repair Of Roof, Chajja, Parapet And Connected Items In Pbor Md Accn In The Area Of Age B/R-Ii Under Ge (West) Delhi Cantt-10. Submission Date for this Tender is 23-04-2024. Shed Construction Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

43073009
Tender For Repair Of Roof, Chajja, Parapet And Connected Items In Pbor Md Accn In The Area Of Age B/R-Ii Under Ge (West) Delhi Cantt-10
Open Tender
Indian
Delhi
delhi
23-04-2024

Tender Details

Repair Of Roof, Chajja, Parapet And Connected Items In Pbor Md Accn In The Area Of Age B / R-Ii Under Ge ( West ) Delhi Cantt-10

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-

BOQ Items

Name of Work: REPIAR OF ROOF, CHAJJA, PARAPET AND CONNECTED ITEMS IN POBRMD ACCN IN THE AREA OF AGE B/R-II UNDER GE (WEST), DELHI CANTT-10
Sl. No. Item Description
1Disconnecting exsiting water storage tanks of capacity exc 250ltr and n exc 500 ltr, removal of unusable tank from site complete all as specified and directed.
2Cleaning and removing all scale and dirt, etc, from tanksand from mouths of circulating pipes, etc. with necessary chemical / bleaching powder, capacity upto 500 ltrs including refixing in any position complete all as specified and directed.
3S&F 500 ltrs capacity rotational molded polyethylene water storage tanks three layered (cylindrical vertical with closed top) hoisted and fixed in position and including 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod & 20mm dia tank nipple suitable for HDPE water tank, complete all as specified and directed.
4Taking up or down 15mm bore of galvanised iron steel tubing and connections including cleaning of serviceable pipe for refixing, cutting/ chasing and making good in CM 1:3 in wall/floorcomplete all as specified and directed.
5M&L 15mm bore dia ofmedium grade galvanised steel tubing with all fittings and fixed complete to wall or laid in floor complete all as specified and directed.
6Fixing only tubes 15mm bore any grade to walls and ceiling or laying in floorscomplete all as specified and directed.
7Taking up or down 20mm bore of galvanised Iron steel tubing and connections including cleaning of serviceable pipefor refixing, cutting/ chasing and making good in CM 1:3 in wall/floorcomplete all as specified and directed.
8S&F 20mm bore ofmedium grade galvanised steel tubing with all fittings and fixed complete to wall or laid in floor complete all as specified and directed.
9Fixing only tubes 20mm any grade to walls and ceiling or laying in floors complete all as specified and directed.
10S&F in repairs 20mm bore dia ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe complete all as specified and directed
11S&F in repair top cover suitable for 500ltr capacity water storage tank complete all as specified and directed.
12S&F in repairs 20mm boregun matel globe or gate valves with iron wheel, screwed both ends for iron pipes fixed complete all as specified and directed.
13Dismantling of brick tiles or terracing tiles single layers as on roof including removal of rubbish beyond MOD land complete all as specified and directed.
14Demolition of mud phuska in roof any thickness including plastering and leeping etc including removal of rubbish beyond MOD land complete all as specified and directed.
15M&L PCC 1:2:4 type B0 (12.5 mm graded stone agg) as in roof padding etc complete all as specified and directed.
16M&L for 40mm thick brick tiles terracing over and including bedding layer of cement mortar 1:6, 15mmthick,including jointed, grouted and flush pointing of roof brick tiles with ready mix cement mortar of approved make complete all as specified and directed.
17All as item No 16 but Except tiles
18M&L for cement concrete 1:2:4 type B-1 (using 20mm graded stone Aggregate) as in bed blocks for gola, hold fast, coping bedding rounded or chamfered complete all as specified and directed.
19M&L jointed, grouted and flush pointing of roof brick tiles with ready mix cement mortar of approved make and including raking out old jointed, grouted / flush pointing, cleaning of brick or brick tiles, laid flat, inroofs, etc complete all as directed and specified.
20Removal of Vegetation from approachable/unapproachable roof of block and surrounding walls by cutting shrubs, wild growth/tree not exc 30cm girth and removing complete vegetation growth from walls including taking out roots from roof/brick walls and making good the disturbed surface with PCC 1:2:4 type B-0 or CM 1:3 as directedand disposing the rubbish beyond MD land complete all as specified and directed
21Cutting and taking outplants, tree roots from Md Accn bldgs in any position and height and treated with necessary chemical/acid to avoid for this growth and making good the disturbed portion with PCC 1:2:4 type BO including finishing etc complete all as specified and directed. (Note: The cost of scaffolding required for repairs is deemed to be in the quoted rate by the Contractor).
22Demolition of brick work built in cement mortar including all quoins, arches, pillars etc including rubbish off the premises beyond MOD land complete all as specified and directed.
23M&L for brick workwith sub class "B" straight or curved on plan exc 6m mean radius and built in CM 1:6 complete all as specified and directed.
24All as per srl item No 23 above but except brick.
25M&L 15mm thick rendering with ready mix mortar of approved make on wall surface finished even and smooth without using extra cement complete all as specified and directed.
26Demolition of reinforced cement concreteas in chajja, kitchen slab, chullah hood, chimney portion, manhole cover and similar workn.exc 15cm thick and removal of rubbish beyond MOD land complete all as specified and directed.
27Use and waste of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding200mm thick (Horizontal or sloping)rough finished surfaces of concrete all as specified and directed.
28M&L for reinforced cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) for slabs supported on walls, beams and columns in floors, roofs, landing, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. (Note :-Steel reinforcement bars shall be measured and paid separately under relevant items)
29S&F for TMT Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
30S&F 110mm bore PVC (SWR) pipes single socketed, in any length including mild steel stack clamps(as per sample) fixed in cement concrete 1:2:4 blocks with rubber ring joints fixed to walls and including taking down eaves gutters and rainwater pipes (any size or pattern), with all fittings viz. heads, shoes, bends, swan-necks etc, removal rubbish beyond MOD land complete all as specified and directed.
31All as per item 30 but 75mm bore
32S&F 110mm bore PVC (SWR) bends with rubber ring joints fixed to walls complete all as specified and directed.
33All as per item 32 but 75mm bore
34Demolition of cement concrete (unreinforced) in ground floor and paving not exc. 15cm thickness (below or above ground level), removal of rubbish beyond MOD land complete all as specified and directed.
35M&L 75mm thickPCC (1:3:6) type C2 (using 20mm stone aggregate) as in floors/pavings /plinth protection etc, finished even and fair with using extra cement grooves filled with bitumen mastic filling of mix (1:2) (bitumen and sand) complete all as specified and directed.
36M&L for 15mm thick rendering with ready mix mortar of approved make on brick work or concrete surfaces on wall, finish the surface even and smooth without using extra cement as whole or in patch etc including taking down cement plaster on brick walls etc including raking out joints hacking for key scrubbing down with water etc all as directed, rubbish of the premises complete all as specified and directed.
37M&L preparation of newly plastered surfacesand applying two coats of cement base paint over a coat of primer on external surfaces of walls complete all as specified and directed.
38M&L salt glazed stone ware gully trap, square or round mouthed, 150 x 150 mm size, shape as required, including taking out of old GT and jointing with old connection and pipes complete all as specified and directed.
39S&F factory made RCC GT Cover of Size 400mm x 500mmx 50mm thick or as per site requirement with 01 No handle and 150mm dia notch at one side of cover at center at 500mm long side complete all as specfied and directed.
40S&F 75mm bore cast iron sand cast soil waste and vent pipe in any length with or without ears with cement joints fixed to walls/ceiling or laid in vertical surfaces and including dismantling of cast iron drain pipes including fittings, jointed in cement mortor complete all as specified and directed.
41All as per item 40 but 100mm bore
42S&F CI branch piece single (equal or unequal) 100 mm ordinary or inverted (spigot or socket type) or with paralled branches complete all as specified and directed.
43S&F100 mm CI bends (any radius) diminishing pieces or taper (large base measured) complete all as specified and directed.
44All as per item No 43 above but 75mm bore.
45M&L for framed work as in door/vent/CB chowkats of angle or other section, frame work for chajjawith gusset plates, cooler stand, rails, braces etc complete drilled for fixing of steel sheeting or other covering and including cutting brick work for hold fast confirming to Fe 410-W (Gde-E-250) quality "A" including necessary welding and including dismantling wrought iron or mild steel work of any description not otherwise provided for concerete all as specified and directed.
46S&F1.00 mm thick plain black mild steel sheeting in as in door shutter covering including, welding or soldered joint complete all as specified and directed.
47M&L for preparation of newsteel surfaces, painting two coats of synthetic enamel paints over a coat of red oxide primerexc 10mm width or girth complete all as specified and directed.
48Taking down door/window/ventilator frames with shuttersexc 1.50 sqm each but n exc 4.0 sqm(without taking off shutters from frame) complete all as specified and directed.
49M&L kota stone slab 18-20 mm thick as a one piece area not exc 1.00 sqm in tread and riser of steps, skirting, dado and pillers laid over 20mm thick screed bed in cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shed of the slab including rubbing and polishing and including demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar and removal of rubbish beyond MOD land complete all as specified and directed.
50M&L preparation of surfaces by complete removal of existing treatment & applying two coats of cement base paint on walls over a coat of primerall as specified & directed. Note : Colour / shade as approved by Engr in charge.
51M & L for providing cemenr concrete type B1:2:4(using 12.5 mm graded aggregate) asplinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating,all as specified & directed.
52M & L for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed.
53S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of Green colour having tensile strength of 550 Mpaand 150 GSM as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
54M& L mild steel framed work sunshed chajja etcwith angle iron welded toghether ends of angle shoulders and fixing of same to brick/concrete surfaceswith necessary steel fastener of required size and numbers as directed by engr-in-charge confirming to FEE-250) quality "B" complete allas specified and directed.
55M&L for 100 mm thickPCC (1:4:8) type D2 (using 40mm stone aggregate) as in sub base of floor complete all as specified and directed.
56M&L for 50mm thick sand cushion/Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
57M&L 60 mm thick Coloured cement concrete interlockingpaver blocks hydraulically pressed of compressive strength not less than M-35 grade with grey cement and pigmentcomplete all as specified and directed
58M&L for 20mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
59M&L for Coloured Machine pressed cement concrete chequered tiles 30cm X 30cm X 25mm thick machine pressed; set jointed and pointed in neat cement slurry in floors and cut and pointed with grey cement and pigment complete all as specified and directed.