Civil Division has published Tender For Construction Of Academic Block-A (G Plus 4) At Bose, Cuttack.. Submission Date for this Tender is 13-06-2024. Building Work Tenders in cuttack Odisha. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 08-Apr-2024 | 1ST CORRIGENDUM | Date | 13-06-2024 |
FileName | File Description | File Size |
ea878d46-8cab-4603-a093-8a28348134e0.html | Tender Notice | 0 KB |
BOQ_500793.xls | Tender Document | 0 KB |
DTCN.pdf | Tender Document | 0 KB |
Tendernotice_1.pdf | Tender Document | 0 KB |
Sl. No. | Item Description |
1 | CIVIL WORK Earth work in excavation of foundation trenches in hard soil including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site within 50m initial lead & 1.5m initial lifts with sundries & T&P required for the work complete including cost of all labour,labour cess,T&P,sundries etc.as directed by the Engineer in charge. |
2 | Ground Floor |
3 | Approach Road |
4 | Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density asper direction of the Engineer-in-charge. |
5 | Approach Road |
6 | Construction of granular sub-base by providing Gr.-VI material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller asper direction of the Engineer-in-charge. |
7 | Approach Road |
8 | Supplying and filling in foundation and plinth with good quality river sand including watering, ramming with cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer-in-charge |
9 | Ground Floor |
10 | Approach Road |
11 | R.C.C. work of M-20 in following works using 12 mm. to 20 mm. (½” to ¾”) size (20 mm. not to exceed 25%) hard black crusher broken granite stone chips of approved quality from approved quarry including hoisting, lowering, laying and compacting concrete, watering curing, centering, shuttering and finishing the exposed surfaces smooth with cost, conveyance, royalties, taxes of all materials with all labour,labour cess and T & P required for the work etc. complete in all respect but excluding the cost and conveyance of M.S. rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position and as per the direction of the Engineer-in-charge. |
12 | Approach Road |
13 | Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP-63:2018 as per direction of the Engineer-in-charge. |
14 | Approach Road |
15 | Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties of all materials and cost of all labours,labour cess, T&P etc complete as per the direction of the Engineer-in-charge. |
16 | Ground Floor |
17 | Approach Road |
18 | Filling in foundtaion and plinth with excavated materials including watering and ramming as directed by the Engineer-in-charge. |
19 | Providing and applying of Pre construction Anti-termite treatment by drilling 12mm dia. holes at distance of 30cm @ junction of wall and floor about 300mm aprt deep enogh to reach the soil below and chemicalemulsion (PREMISE, IMIDACHLOPRIED 30.5SC OF BAYER MAKE mixed with 47.5 ltr water) pumped these holes to soak the soil @ 1 ltr soulation of each hole as per manufactures specification and the holes should be pluged with filling materials including cost of all material, labour conveyance and hiring charges of machinaries all taxesas per direction of EIC. |
20 | Providing lifting, hoisting and laying R.C.C. of M-30 Grade not less than 380 Kg/Cum cement using (opc/ppc/composite) to base of columns and footing, columns, beams, plinth band, lintels, chajja, shaft, fins, roof slabs, balconies, stair cases, parapets, window sills, lofts, railing, jally, copping or in places as shown in the drawing for all floors with 20mm and down graded size black hard crusher broken ships of approved quality from approved quarry including mixing and vibro compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth (if required providing plaster with cement mortar (1:4) wherever necessary without any extra cost) including rigid smooth centering and shuttering, scafolding, watering (excluding reinforcement bars) and curing for required period including cost of all material, labour, conveyance, royality, loading and unloading, sundries, tools and plants etc. complete as per the direction of the Engineer in Charge. |
21 | BUILDING PROPER |
22 | Column base footting |
23 | Plinth beam |
24 | COLUMN |
25 | Ground Floor |
26 | First Floor |
27 | Second Floor |
28 | Third Floor |
29 | Fourth Floor |
30 | Terrace Floor |
31 | LINTEL |
32 | Ground Floor |
33 | First Floor |
34 | Second Floor |
35 | Third Floor |
36 | Fourth Floor |
37 | Terrace Floor |
38 | CHAJJA |
39 | Ground Floor |
40 | First Floor |
41 | Second Floor |
42 | Third Floor |
43 | Fourth Floor |
44 | Terrace Floor |
45 | FINS |
46 | Ground Floor |
47 | First Floor |
48 | Second Floor |
49 | Third Floor |
50 | Fourth Floor |
51 | Terrace Floor |
52 | STAIRCASE |
53 | Ground Floor |
54 | First Floor |
55 | Second Floor |
56 | Third Floor |
57 | Fourth Floor |
58 | ROOF BBEAM |
59 | Ground Floor |
60 | First Floor |
61 | Second Floor |
62 | Third Floor |
63 | Fourth Floor |
64 | Terrace Floor |
65 | ROOF SLAB |
66 | Ground Floor |
67 | First Floor |
68 | Second Floor |
69 | Third Floor |
70 | Fourth Floor |
71 | Terrace Floor |
72 | SHELVES |
73 | Second Floor |
74 | Third Floor |
75 | Fourth Floor |
76 | Fly Ash brick masonry in cement mortar (1:6) in foundation & plinth using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. |
77 | Ground Floor |
78 | Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. |
79 | Ground Floor |
80 | First Floor |
81 | Second Floor |
82 | Third Floor |
83 | Fourth Floor |
84 | Terrace Floor |
85 | Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL / SHYAM STEEL/ SEL Tiger (grade Fe-500D) etc. includingbending, binding, welding and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge. |
86 | Ground Floor |
87 | First Floor |
88 | Second Floor |
89 | Third Floor |
90 | Fourth Floor |
91 | Terrace Floor |
92 | Supplying, fitting and fixing of openable UPVC doors with door frame of approved make with 6mm thick glass of apprved make (Prominence / FENESTA/NCL VEKA LTD./Koemmerling/ DURAPLAST) quality complete with frame, shutters and all fittings and fixtures including all cost,conveyance,royalty & taxes of all materials,labour,T&P required for the work etc. complete as per specification & direction of the Engineer-in-charge. |
93 | Ground Floor |
94 | First Floor |
95 | Second Floor |
96 | Third Floor |
97 | Fourth Floor |
98 | Terrace Floor |
99 | Supplying, fitting, fixing of Un-plasticised Poly Vinyl Chloride (UPVC) (FENESTA / NCL VEKA LTD.). Casment window with top fixed-60 -series duly manufactured using UPVC reinforced profiles of 60mm x 55mm x 2.5mm for outer frames75mm x 60mm x 2.5mm for outer frames, 75mm x 60mm x 2.25mm for casement window sash profile capable of mounting single glazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5mm prefabricated & welded through fusion welding the window sash shall be fitted with 6mm thick clear toughened glass of SAINT-GOBAIN make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 No., per set of sashes and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing / deglazing at site etc. including cost and conveyance of all materials, accessiries, labour charges, materials and product conforming to ASTM D 638-14, EN-477-95 and other applicable codes and standards etc. complete as per direction of the Engineer-In-Charge. |
100 | Ground Floor |
101 | First Floor |
102 | Second Floor |
103 | Third Floor |
104 | Fourth Floor |
105 | Supplying, fitting, fixing of Un-plasticised Poly Vinyl Chloride (UPVC) (FENESTA / NCL VEKA LTD.) Ventilator / Top Hung - 60 - Series duly manufactured using UPVC reinforced profiles of 60mm x 55mm x 2.5mm for outer frames, 75mm x 60mm x 2.25mm for casement window sash profile capable of mounting single glazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5mm prefabricated & welded through fusion welding the window sash shall be fitted with 6mm thick clear toughened glass of SAINT-GOBAIN make duly fixed with EPDM weathering seal resistant accessories like clipping locking system made of aluminium 1 No., per set of sashes and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing / deglazing at site etc. including cost and conveyance of all materials, accessiries, labour charges, materials and product conforming to ASTM D 638-14, EN-477-95 and other applicable codes and standards etc. complete as per direction of the Engineer-In-Charge. |
106 | Ground Floor |
107 | First Floor |
108 | Second Floor |
109 | Third Floor |
110 | Fourth Floor |
111 | Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar/ flat including stair case hand railing with 40mm. dia G.I.pipe etc. including painting two coats over a coat of redoxide primer as per approved drawing and designwith cost of all materials & labour, labour cess, T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-Charge. |
112 | Ground Floor |
113 | First Floor |
114 | Second Floor |
115 | Third Floor |
116 | Fourth Floor |
117 | Terrace Floor |
118 | Supplying fitting fixing of M.S.Trusses using 75mmx75mm size MS square bars, 20mmx5mm MS flats, MS angles of approved size for Grill gate, PCC(1:2:4) for clamp fixing cost & conveyance of all materials, labours , T&P, all fabrication, erection and fitting in position etc all complete as per direction of E.I.C. |
119 | Terrace Floor |
120 | Supplying fitting, fixing of 125 mm x65mm( after moulding ) well blend beautiful WPC ( Wood plastic composite choukath in door opening area tha wall surface of WPC Chaukaths 150mm anchor fastnerscrew cuttingthe holes filling the cutting holes in cement concrete (1:2:4) etcallcomplete in all respect as per specification & direction of the Engineer-in-Charge. |
121 | Ground Floor |
122 | First Floor |
123 | Second Floor |
124 | Third Floor |
125 | Fourth Floor |
126 | Providing and fixing of 30mm thick WPC door shutter with hinges tower bolt handle stainless steel serews etcincluding all cost of material as per direction of Engineer-in-charge. |
127 | Ground Floor |
128 | First Floor |
129 | Second Floor |
130 | Third Floor |
131 | Fourth Floor |
132 | Providing and fixing ISI marked 35 mm thick flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak three ply veneering with vertical grains or cross bands and face veneers on both faces of shutters of approved design including cost of all door fittings and fixtures etc. complete in all respect as per specification & direction of the Engineer-in-Charge. |
133 | First Floor |
134 | Second Floor |
135 | Third Floor |
136 | Fourth Floor |
137 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge. (Make-JINDAL ) |
138 | Ground Floor |
139 | First Floor |
140 | Second Floor |
141 | Third Floor |
142 | Fourth Floor |
143 | Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. |
144 | Ground Floor |
145 | First Floor |
146 | Second Floor |
147 | Third Floor |
148 | Fourth Floor |
149 | Terrace Floor |
150 | Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. |
151 | Ground Floor |
152 | First Floor |
153 | Second Floor |
154 | Third Floor |
155 | Fourth Floor |
156 | Terrace Floor |
157 | Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. |
158 | Ground Floor |
159 | First Floor |
160 | Second Floor |
161 | Third Floor |
162 | Fourth Floor |
163 | Terrace Floor |
164 | Fixing granite stone of approved dimension area above 0.4 sqm (20mm thick) in floor, treads of steps and landing on 20mm thick bed of cement mortar (1:4) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials complete in all respects as per direction of Engineer-in-Charge. |
165 | Ground Floor |
166 | First Floor |
167 | Second Floor |
168 | Third Floor |
169 | Fourth Floor |
170 | Terrace Floor |
171 | Fixing granite stone of approved dimension area above 0.4 sqm (20mm thick) in Dados, treads of steps and landing on 12mm thick cement mortar (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties and taxes of all materials complete in all respects as per direction of Engineer-in-Charge. |
172 | Ground Floor |
173 | First Floor |
174 | Second Floor |
175 | Third Floor |
176 | Fourth Floor |
177 | Terrace Floor |
178 | Fixing of Chequered tiles of premium grade having thickness 7mm to 8mm confirming to IS 13755 of size 30cm x 30cm special plain / printed series in floors over 20mm thick bed of cement mortar 1:4 jointed with cement slurry mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance & royalties of all materials, labour with T&P complete in all respects as per direction of Engineer-in-Charge. |
179 | Ground Floor |
180 | Fixing of Kota stone tile of minium thickness 16mm thick of premium grade of size above 0.10 Sqm. in floors over 20mm thick bed of cement mortar 1:4 (1cement:4course sand)and filling the joint with white cement mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance,royalties of all materials, labour,labour cess with T&P complete in all respects as per direction of Engineer-in-Charge. |
181 | Ground Floor |
182 | Supplying, fitting and fixing vetrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm Plian (Ivory) ofapproved make (JOHNSON /OASIS / SOMANY/ KAJARIA/ RAK) in floors on 20mm thick bed of C.M. (1:4)(1cement:4course sand) and filling the joint with white cement mixed with pigment to match the shades of the tileincluding cost of all materials, labour, labour cess, T&P etc. required for the work completein all respect as directed by the Engineer in charge. |
183 | Ground Floor |
184 | First Floor |
185 | Second Floor |
186 | Third Floor |
187 | Fourth Floor |
188 | Providing, fitting, fixing vitrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm Plain (Ivory) of approved make (JOHNSON /OASIS / SOMANY/ KAJARIA/ RAK)as directed by Engineer-in-charge in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials all labour,labour cess complete in all respects. |
189 | Ground Floor |
190 | First Floor |
191 | Second Floor |
192 | Third Floor |
193 | Fourth Floor |
194 | Painting two coat with approved synthetic enamel paint to newwood & iron work over a coat of Red oxide primer including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge. (Make-Asian/ Berger/ ICI or equivalent make duly approved by Engineer-in-charge). |
195 | Ground Floor |
196 | First Floor |
197 | Second Floor |
198 | Third Floor |
199 | Fourth Floor |
200 | Terrace Floor |
201 | Providing and fixing of Fixed Glazing with part Top hung of approved make to be fabricated from roll formed sections made of pre-painted steel (base steel as per IS-513 of 0.6mm thick "D" quality galvanized as per IS-277 with zinc of 120 Gm/sqm) and standards etc. complete as per direction of the Engineer-In-Charge. |
202 | Ground Floor |
203 | First Floor |
204 | Second Floor |
205 | Third Floor |
206 | Fourth Floor |
207 | Terrace Floor |
208 | Finishing plastered surfaces of walls with cement based wall acrycil putty (Water based) of approved make (JK White/ Birla white or equivalent make duly approved by Engineer-in-Charge) and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge. |
209 | Ground Floor |
210 | First Floor |
211 | Second Floor |
212 | Third Floor |
213 | Fourth Floor |
214 | Terrace Floor |
215 | Painting two coats withPlastic Emulsion paint over a coat of water bond cement primer to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge. (Make: Asian/ Berger/ ICI/ equivalent make) |
216 | Ground Floor |
217 | First Floor |
218 | Second Floor |
219 | Third Floor |
220 | Fourth Floor |
221 | Terrace Floor |
222 | Wall painting two coats with Weather coat paint (1st quality) exterior grade of approved make & approved shade over a coat of primer to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-Charge. (Make: Asian/ Berger/ ICI or equivalent make duly approved by Engineer-in-Charge). |
223 | Ground Floor |
224 | First Floor |
225 | Second Floor |
226 | Third Floor |
227 | Fourth Floor |
228 | Terrace Floor |
229 | Providing 2.5cm thick Grading Concrete over roof slab with cement concrete (1:2:2) using 6mm size black hard granite crusher broken chips and screened & washed sharp sand for mortar and finished smooth to the rough surface of slab including watering and curing with cost, conveyance, royalties of all materials with cost of all labour, labour cess and T&P required for the work etc. complete in all respect as directed by the Engineer in charge. |
230 | Ground Floor |
231 | Terrace Floor |
232 | Fixing of Ceramic glazed wall tiles of premium grade having thickness 6.5mm to 6.7mm confirming to IS 13753 of size 30cm x 20cm / 20cm x 20cm special plain / printed series in dados skirting & riser of steps on 12mm thick cement plaster 1:3 joined with neat cement slurry mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance,royalties of all materials, labour with T&P complete in all respects as per direction of Engineer-in-Charge. |
233 | Second Floor |
234 | Third Floor |
235 | Fourth Floor |
236 | Supplying all labour with T&P required for fitting and fixing of stage using 25mm thick BWR solid ply of approved qualty including all cost of materials , labour & T&P required for the work etc complete. |
237 | Fourth Floor |
238 | Providing, fitting fixing ofWall panelling made out of Al Section no B9835 as Horizontal and vertical member placed @ 600 mm C/C covered with 18mm thick veneer of approved quality with melamine polish with all cost, labour & T&P required for the work etc as per direction of EIC. |
239 | Fourth Floor |
240 | Providing fitting fixing Mineral fibre grid tile false ceiling with 600X600X16 mm size board with frames as per approved specifications including all fittings etc with cost of all labour, conveyance, loading, unloading, T&P, etc, complete as per the direction of Engineer-in-Charge |
241 | Fourth Floor |
242 | Supplying fitting & fixing of 6 mm thick Poly Carbonate Sheet of approved design of approved quality iconforming to IS 14443:1997 |
243 | Terrace Floor |
244 | Providing, Fitting & Fixing of 100mm dia PVC Rain water pipewith cost, conveyance, royalties of all materials with cost of all labour,labour cess, and T&P required for the work etc. complete in all respect as directed by the Engineer in charge. |
245 | Terrace Floor |
246 | Dismantling brick or stone masonry in lime or cement mortar above 3m height including stacking the useful materials for re-use and removing the debris with in 50m lead including cost of all labour with T&P etc. complete as per the specification and direction of the Engineer-in-charge. |
247 | Dismantling G.C.I. or A.C. sheet roofing after carefully removing the bolts and nuts including stacking of he materials for reuse and removing the debris within 50m lead including cost of all labour with T&P etc. complete as per the specification and direction of the Engineer-in-charge. |
248 | Dismantling and removing doors, windows and ventilators including removal of frame, hinges, fastening and stacking the same for reuse and removing the debris within 50m lead including cost of all labour with T&P etc. complete as per the specification and direction of the Engineer-in-charge. |
249 | E.I. WORK Recessed wiring to light point/ fan point/Exhaust fan point/Call bell point with 1.5sqmm FRLS PVC Insulated single core multistarand copper Conductorof ISI marked with 20mm diaPVC HMS conduit(make Precesion/NORPACK)with 6A 250V MODULAR type switch ISI marked and ceiling rose marked mounted on Modular GI Boxhaving front modular base plateof suitable size, with 1.5sqmm FRLS PVC Single core multistrand copper conductor as earth wire includingallaccessories and connection as per direction of Engineer in charge (Make of wire Finolex / Havells / Anchor / Finolex/Polycab/) switch /socket/modular GI Board (Make: legrand Myrius Next Gen -antibacterial/panasonic vision)GROUP-A Light Point |
250 | GROUP-BLight Point |
251 | GROUP-CLight Point |
252 | GROUP-BFan Point |
253 | GROUP-CFan Point |
254 | GROUP-C Call Bell Point |
255 | Supply and fixing of 6Amp plugwith 6Amp switch on existing board (Modulartype) (Make: legrand Myrius/panasonic vision) |
256 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (anti bactorial & flame retradant type))with suitable size modular box & cover(anti bactorial & falme retradant type) including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision)or equievalant make & model ISI marked as approved , complete suitable for office standard hospital.(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 yearsagainst manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
257 | S/F of modular box with cover of suitable nominal size of surface or in recessincluding providing and fixing of 5 pin,15/16 AmpModular socket out letand 15/16 AmpModular switch ISI marked connection painting etc as required complete in all respect as per direction of Engineer in charge Make: legrand Myrius Next Gen -antibacterial/panasonic vision |
258 | S/F of Multipurpose boardconsisting 2nos. 6Amp plug and switch with all connections ( Legrand mylinc/ Schneider clipsal/Hager insysta/Anchor Dura/ or equivalent) |
259 | S/F of Multipurposeboard consisting 3nos. 6Amp plug and switchModular on metal box and Modular cover with all connections ( Legrand mylinc/ Schneider clipsal/Hager insysta/Anchor Dura/ or equivalent) |
260 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLSH/LSZHinsulated, copper conductor, single core cable (Finolex/Anchor/Polycab/ HAVELLS/RR KEBLE) or equievalant reputed make A catagory ISI marked as approved, inrecessed PVC conduit Heavy duty FRLS of mentioned size (NORPACK/Anchor or equievalantISI marked as approved) as required as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallicheavy duty flexible conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
261 | 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallicheavy duty flexible conduit.(BDB to LSB/LIGHT CKT/5A PLUG/INVERTER POINT TO EACH QTR) (2X2.5+1X1.5) |
262 | 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallicheavy duty flexible conduit .(PDB to PSB/ GAYSER POINT/AC POINT/ROOM LIGHT CONTROL TO CORRIDOORPOINT/DG PANELESSENTIAL LOAD) (2X4+1X1.5) |
263 | 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallicheavy duty flexible conduit .(LFDB TO LBDB) (2X6+1X2.5) |
264 | 4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 2.5 sq. mm copper wire for earth continuty conductor in 32mm dia non metallicheavy duty flexible conduit.(LFDB TO LBDB/power unit/point) (4X6+1X2.5) |
265 | 4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6sq. mm copper wire for earth continuty conductorin 32 mm dia non metallicheavy duty flexible conduit .(LFDB TO FLOOR PANEL TO TPN BDB light ) (4X10+1X4) |
266 | S/F of Multipurpose boardconsisting 2nos. 6Amp plug and switch with all connections ( Legrand mylinc/ Schneider clipsal/Hager insysta/Anchor Dura/ or equivalent) |
267 | S/F of Multipurposeboard consisting 3nos. 6Amp plug and switchModular on metal box and Modular cover with all connections ( Legrand mylinc/ Schneider clipsal/Hager insysta/Anchor Dura/ or equivalent) |
268 | Supplying and installation of AC starter Modular type, Equievalant higher model of Legrand/Schneider/Siemens make or equievalant reputed make & model A catagory ISI marked as approved coil voltage-415 Volt A.C. & O/L range of 9-14A range on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
269 | Supply and fixingCALL bell (Ding dong type) /Buzzer on the existing switch box/cover. Equievalant higher model ofLegrand/Schneider/Siemens/Panasonicmake or equievalant reputed make & model A catagory ISI marked as approved .as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
270 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells/Panasonic or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling roseas per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 5 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
271 | Supplying,laying of 3cx2.5 sq.mm copperarmouredflexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Make -Finolex/polycab or equievalant |
272 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep(Make-Equievalant higher model with 5 star ratedof Havells/almonard/Anchor/Panasonic/Ushaof exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
273 | Supply and fixingof 48 inch / 1200mm BLDC Celling Fan with Aluminium Blades having wattage not more than 28W and Air delivery = 215(m3/min) with fan regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge.Replacement warranty shall be 4 years. (Usha Technix/Crompton Energion Groove/Havells efficiencia neo) |
274 | Supplying and fixing of Energy efficient surface mounted square shape 18 W LED luminaire ofwhite powder coated , die-castAlluminiumhousingwith high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not lessthan 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operationon 220 V to 240 Vsupply as required as per direction of Engg.-in-Charge. ( Make :Panasonic/Havells/PHILIPS/Wipro/Orient/ LT The luminaire should have Replacement Warranty of 5 years. |
275 | Supplying and fixing of Energy efficient recess mounted LED luminaire with white powder coated ,pressure die-cast Al housing ,with high transmititivity,non-yellowing PMMA diffuser, with wattage not more than 36 watt and lumen efficacy not less than ( 130 lumens/watt ) of size 595 x595 x 70 mm , ,CRI not lessthan 80,CCT of 5700-6500 degree K,THD less than 10%, with Non integrated isolateddriver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation), all other accessories , life : 50,000 burning hours (5 years warranty) , Internal surge protection of 3 KV suitable for operationon 230 V, 50 Hz supply as required as per direction of Engg.-in-Charge. ( Make : Panasonic/ LT /Wipro/PHILIPS/Havells .) The luminaire should have Replacement Warranty of 5 years. |
276 | Supply and fixing of 20Watt Different type LED tube lights(Make-Havells/ Cromption/ wipro/ panasonic/ Orient/ Philips) |
277 | Supply ,Installation testing commissioning of 100 watt highbay light High efficient LED with aluminium housing in Pure Polyster UV resistant powder coated black finish and Top maintainable product with top opening die cast cover with acrylic clear glass reflector.CRI>70, IP66, Ambient temp-0 to 45DegC, Driver efficiency>85%, CCT-4000/5700K,THD<10%,Powerfactor>0.95, Surge protection-4 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 150-300V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. Luminaire lumen = 11000 lumens (110 lm/W). Similar toPanasonic/similar modelofof LT /Wipro/PHILIPS/Orient/ Havells. with proper model make having warrantied for a period of 2 years .The luminaire to be installed through moveable G.I braket as per the direction of Engg-in -charge. |
278 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge . (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. |
279 | Supplying and fixing of Energy efficient Recess mounted LED luminaire made up of CRCA powder coatedsheet steel housingof 595 X 595 mm x 70 mmsize with of not more than24W and system lumens output not less than 3250lumens (120 lm/ wt)withdiffusers for better light transmission and pure effect with High luminous flux LEDs for better light output, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV,complete with Non integrated isolated electronic driver(protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty)supply .as required as per direction of Engg.-in-Charge (Make: Panasonic/similar modelofof LT /Wipro/PHILIPS/Orient/ Havells) . The luminaire must be Replacement Warranty will be 2years. |
280 | SITC of IP 20 Non-integral flexible LED strip light,High optically efficient diffuser,, 4000K with 12 w/mtr @ 5Mtrpool with Driver extra as required as per direction of Engg.-in-Charge ( Make : PanasonicModel No:PSLM06604with DriverPanasonic/similar modelofof LT /Wipro/PHILIPS/Orient/ HavellsThe luminaire should be Replacement Warranty will be 5 years |
281 | S/F of 4 way TPN (8+12) MCB DB on existgsurface / wall mounting with all connection complete in all respect as per direction of engineer incharge (Make : Schneider (ACTI 9 ) /legrand (Ekinox 3) /siemens (Betaguard)/hager) |
282 | S/F of 12 Way SPN MCB DB on existgsurface / wall mounting with all connection complete in all respect as per direction of engineer incharge (Make : Schneider (ACTI 9 ) /legrand (Ekinox 3) /siemens (Betaguard)/hager) |
283 | Supply and fixing of 32Amp DP MCB rating 240 V/415 V "C" series MCB suitable for lighting and other loads of the following poles in the exiting MCB DB ISI marked complete with connections testing and commissioning etc. (Make-Legrand/ Hager/ Simens/ schneider) |
284 | Supply and Fixing of SP 6-32 A rating 240 V "C" Series miniature circuit breaker suitable for lighting and other loads in the loads in the existing MCB DB ISI marked complete with connections testing and commissioning completein all respect as per direction of engineer incharge (Make :Legrand/Schnider/Simens/hager) |
285 | Supplying and fixing 63Amps DP 240 volts, RCCB,300mA Make-Equievalant highermodel ofLegrand/Siemens-Betaguard/ Schneider- Acti 9 or equievalant reputed make & model A catagory ISI marked as approved in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.TheRCCBshould be Replacement Warranty will be 5 years |
286 | Supplying and fixing 63Amps TPN 415 volts, RCCB,300mA Make-Equievalant highermodel ofLegrand/Siemens-Betaguard/ Schneider- Acti 9 or equievalant reputed make & model A catagory ISI marked as approved in the existing MCB DBin the existing MCB DB complete with connections as per direction of Engg.-in-Charge.(for power BDB & AC ODU, 8 way TPN BDB IC).The RCCBshould be Replacement Warranty will be 5 years |
287 | Supplying and fixing 32/25Amps TPN 415 volts, MCB Make-Equievalant highermodel ofLegrand/Snheider/Siemens / L&T/Panasonic /ABB or equievalant reputed make & model A catagory ISI marked as approved in the existing MCB DBin the existing MCB DB complete with connections as per direction of Engg.-in-Charge.(for power BDB & AC ODU, 8 way TPN BDB IC).The RCCBshould be Replacement Warranty will be 5 years |
288 | Supply and fixing of 16Amp to 32A 4P rating 240 V/415 V "C" series MCB suitable for lighting and other loads of the following poles in the exiting MCB DB ISI marked complete with connections testing and commissioning etc.(Make-Legrand/ Hager/ Simens/ schneider) |
289 | Supply and fixing copper plate earthing 600 mm X 600 mm X 3.15 mm thick ISI marked including accessories and providing masonarywith charcoal and salt as required. |
290 | Supply and fixing of G.I Earthing with G.I earth pipe 3mtr. Long 40mm dia ISI marked including accessories and providing masonary with charcoal and salt as required. |
291 | Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing as required.as per direction of Engg.-in-Charge. |
292 | Providing and fixing 25mm x 5 mm copper strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
293 | Providing and fixing 25mm x 5 mm gi strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
294 | Providing and fixing 5mm x 4 mm copper strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
295 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE propertyAL. conductor power cable of 1.1 KV gradePOLYCAB/HAVELLS/Finolex or equievalant reputed make ISI marked as approved of following size cables as per direction of Engg.-in-Charge.Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials3.5core x 300 sq mm ( TO TR. TO MDB 2 RUNS,1 RUNS FOR DG ) |
296 | 3.5core x 95 sq mm |
297 | 3.5core x 50 sq mm |
298 | 4core x 16 sq mm |
299 | 4 core x 4 sq mm |
300 | 3.5core x 35 sq mm |
301 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 25 SQ. MMdirect in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
302 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade sizeexceeding 25 SQ. MMbut not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
303 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade sizeexceeding 120 SQ. MMbut not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
304 | Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. 3.5 core x300 sq mm |
305 | 3.5core x 50 sq mm |
306 | 4 core x16sq mm |
307 | 3.5 core x35 sq mm |
308 | 3.5 core x95 sq mm |
309 | Aluminium alloy tubular bimetallic heavy duty cable socket. 16 mm |
310 | 25 mm |
311 | 50 mm |
312 | 95 mm |
313 | Providing,fixing and laying offollowing dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. 50 mm dia |
314 | Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete withfitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. 200 mm dia |
315 | MAIN CONTROLPANEL AT GF (all block A ) |
316 | S/F of 800 Acubical panel boardmade of 2mm C.R sheet with powder coated with provision of following items as incomer ,800A 4P 50KA MCCB,250A changeover,65 ka type 1+2 spd,MFM,Indicator,on,off ,trip indication 12 nos 63-100A 16ka 4p mccb,160A 4p 25ka mccb -2nos as outgoing feederwith fabrication erection testing & comissioning of total enclosed panel board of size 2100*1650*450mm with copper busbar. busbar of 800A, 415V 4stripinternal connection & provision for termination of incomming & out going cable , earthing etc in complete as per the direction of engineer incharge |
317 | S/F of 63 /100A cubicalEI subpanel boardmade of 2mmC.R sheet with powder coated with provision of following items with fabrication erection testing & comissioning of total enclosed panel board of size not less than 24"x 12"x 8" with copper busbar , 415V 4strip & internal connection & provision for termination of incomming & out going cable , earthing,cable alley etc, complete |
318 | S/F of 200Acubical panel boardmade of 2mm C.R sheet with powder coated with provision of following items 65 ka type 1+2 spd,MFM,Indicator,on,off ,trip indicationas outgoing feederwith fabrication erection testing & comissioning of total enclosed panel board of size 36"x24"X18"with Cu. busbar of 400A, 415V 4stripinternal connection & provision for termination of incomming & out going cable , earthing etc in complete as per the direction of engineer incharge |
319 | Supply and fixing of 4 pole MCCB 16-100 A,Ics = 100% Icu, 25 KA breaking capacity, adjustableThermal,fixedmagnetic type in existing cubicle panel board including drilling holes in cubcle panel, making connections, etc. as required completein all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand(Ekinox)/siemens(betaguard)/hager |
320 | Supply and fixing of 4 pole MCCB 16-100 A,Ics = 100% Icu, 16 KA breaking capacity, adjustableThermal,fixedmagnetic type in existing cubicle panel board including drilling holes in cubcle panel, making connections, etc. as required completein all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand(Ekinox)/siemens(betaguard)/hager |
321 | Supply and fixing of 4 pole MCCB 800A,Ics = 100% Icu, 50KA breaking capacity, adjustableThermal,fixedmagnetic type in existing cubicle panel board including drilling holes in cubcle panel, making connections, etc. as required completein all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand(Ekinox)/siemens(betaguard)/hager |
322 | Supply and fixing of 4 pole MCCB 160A,Ics = 100% Icu, 25KA breaking capacity, adjustableThermal,fixedmagnetic type in existing cubicle panel board including drilling holes in cubcle panel, making connections, etc. as required completein all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand(Ekinox)/siemens(betaguard)/hager |
323 | Supply and fixing of 4 pole MCCB 200A,Ics = 100% Icu, 36KA breaking capacity, adjustableThermal,fixedmagnetic type in existing cubicle panel board including drilling holes in cubcle panel, making connections, etc. as required completein all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand(Ekinox)/siemens(betaguard)/hager |
324 | HOT DIPP GALVANIZED(GC) AS PER EN-ISO-1461 ,CARBON STEEL WIRE MESH CABLE TRAYS with internal dimensions ofsize 54mm(H) x 300mm(W),of Legrand/C&S/OBO or equievalant reputed make & model A catogory, ISI marked as approved.The Load bearing capacity of the Cable Traysshould be minimum of104.8Kg/meter at the span of1.5Meter as per UL specifications.(With all accessories,bend,cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTORas required as per direction of Engg.-in-Charge. Warrentee period oftraymust be 2 years & compelete test certificate must be submitted . |
325 | Supply,Installation, Testing & Commissioning of of 16(TSixteen) Passenger gearless Machine roomCapacity(1088 Kg),Elevator G+4 Floors with ACVVVF drive/Control for constant load of 1088 kg ARD 1.5 MPS,honeycomb interior with simplex operation without attendant car position indicators,battery operated alarm bell & emegency light,mirror finish door finished car interior,power operated centre opening automatic sliding stainless doors for car entrance & hoist way entrance etc . Machine beams,buffer support channels,facia plate including sills pit ladder metal screen in Elevator pit etc.as per specifiaction including cost of (i)Overload detection,(ii)Voice announcement,(iii) Intercom,(iv)Braille Buttons with all Civil & Electrical works required for installation of Elevator in the existing lift well and machine room,scaffolding ,floor cuttingincluding Fireman"s switch complete in all respect.The Elevator should be suitable for physically handicapped .person.make:OTIS/Mitsubishi/ kone/Schindler |
326 | Supply , Installation,Testing and Commissioningof 8 mm Aluminum Round Conductor OBO Type No.RD 8/ALU I (5450086) /Dehn |
327 | Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black@ 1 meter distance. OBO Type No.165 MBG-8-10 ( 5218700 )/Dehn |
328 | For T cross and parallel connectors. Made of Stainless SteelQuickinstallation using hexagonal bolt M10X30 high-grade stainless steel. Tested for 100kA lightning current. 249 8-10 VA (5311551) /Dehn |
329 | Providing of expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length over 20 meters. For round conductor Rd 8/ALU. OBO Type No. 172 AR ( 5218926 )/Dehn |
330 | Supply , Installation,Testing and Commissioningof 1 mtr vertical air terminal with mounting accessorieson the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. OBO type No.F-FIX JUNIOR (5403308) /Dehn |
331 | Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mmaluminium rod:3 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. OBO Type No. 101 VL3000. /Dehn |
332 | Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and tested upto 100KA lightning current . OBO type No.F-FIX-16 (5403200) /Dehn |
333 | Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and tested upto 100KA lightning current . OBO type No.F-FIX-S16 I (5450080) /Dehn |
334 | Supply , Installation,Testing and Commissioningof Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. OBO Type No. 5052 DIN 30X3 ( 5450436 )/Dehn |
335 | Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. OBO Type No. 255 FL30 FT (5314534 )/Dehn |
336 | Supply , Installation,Testing and Commissioningof flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black OBO Type No. 833 35 (5033039) /Dehn |
337 | Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. OBO Type No.356 50 ( 2360055 )/Dehn |
338 | Supply , Installation,Testing and Commissioningof UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 14.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 OBO Type No. 14 3000 CCER (5450010)/Dehn |
339 | Supply , Installation,Testing and Commissioningof universal clamp made of SS to connect rod with flat conductor OBO Type No. 14 25 RTC (5450066) /Dehn |
340 | Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested OBO Type No.OEC 2 25 (5450058)./Dehn |
341 | The above arrangements shall be provided withHeavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system OBO Type No.UFE (5450030)/Dehn. |
342 | SS Screw and Grip , M10X50mm. (NON OBO Item) |
343 | Data Networking System. Supply and Installation of Cat6 I/O with Single Port Face plate : The Outlet shall meet or exceed requirement as per ANSI/TIA 568.2-D, ISO/IEC 11801 & IEC 60603-7-41. The Information Outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and Return Loss should be verified for CAT6 @ 250 Mhz and CAT6A @ 500Mhz. The PCB Material shall be FR-4 and having a thickness of 1.2mm. The connector shall be compatible as per IEE 802.3bt Standard for PoE application. The PVC material of the Face Plate should comply to ABS/UL94-V-0 Certified.Shall be ETL Verified for a 4 Connector Channel performance alongwith MTPL up to 635 Mhz, Shall be RoHS Compliant.OEM shall be ISO 9001:2015, ISO 14001:2015 and ISO 45001:2018 Make:R&M/3C3/Legrand |
344 | I/O Dual |
345 | Supply and laying of 4 Pair Cat6 U/UTP Cable in the existing surface / recessed steel / PVC conduit as required. The 4 Pair Unshielded Twisted Pair cable shall be UL Listed exceed the requirement of ANSI/TIA 568.2-D and ISO/IEC 11801 Class E, 4 Twisted Pair seperated by internal HDPE Cross Filler alongwith RIP Cord. Insertion Loss of 32.8 dB/100 mtrs at 250 Mhz. Cable should support Operating Temperature from -20°C to +60°C. Cable support Delay Skew < 45 ns/100m, Operating Voltageof 72V, Impedance : 100 ± 15? @ 100 Mhz and Propagation Delay @ 250 Mhz : 536 ns/100m, Shall be ETL Verified for a 4 Connector Channel performance alongwith MTPL up to 635 Mhz, Shall be RoHS Compliant.OEM shall be ISO 9001:2015, ISO 14001:2015 and ISO 45001:2018 Make:R&M/3C3/Legrand |
346 | Supply and installation of CAT6, 24-Port Loaded, 1U Modular Jack Panel. Should accommodate CAT6 in a Zig-Zag/ Staggred manner with Rear Cable Management and Front removable RJ45 Information outlet. Should have easy clip management with labels and clear label covers, Constructed with SPCC having a thickness of 1.5 mm and Non Corrosive with CAT6 RJ45 X 24 Ports with Color code front panel with patch cord locking. Shall be RoHS Compliant and ETL Verified for a 4 Connector Channel performance alongwith MTPL up to 635 Mhz, and be tested as per ASTM B117:2019 and Shall be RoHS Compliant.OEM shall be ISO 9001:2015, ISO 14001:2015 and ISO 45001:2018 Make:R&M/3C3/Legrand |
347 | Supply and installation of CAT6 U/UTP 24 AWG Patch Cord. Factory Tested for better Quality and suitable for High Speed Data Transmission. Complies to the Standard ANSI/TIA-568.2-D Standards. Support Data Networks Speeds Up to 10/100-Base-T and 1000 Base-T. Available in LSZH Jacketto reduce Toxic Gasses Emitted during Combustion. RJ45, 8P8C, 2 Fork 50µ Gold Plated Contacts, Transparent Boot Cable Assemblies 1 Mtrs. Lenght. Shall be RoHS Compliant and ETL Verified for a 4 Connector Channel performance verified alongwith MTPL up to 635 Mhz, Shall be RoHS Compliant.OEM shall be ISO 9001:2015, ISO 14001:2015 and ISO 45001:2018.(All necessary documents to be Attached Make:R&M/3C3/Legrand |
348 | 2mtrs Length |
349 | Supply & fixing of 12U 600 mm DepthWall mount Rack loaded withFAN,PDU,Cable Mnager& Screw Pkt. Make: APW/ Valrack/ D-Link |
350 | Supply & fixing of 27U 600*900 Floor mount Rack oaded withFAN,PDU,Cable Mnager& Screw Pkt. Make: APW/ Valrack/ D-Link |
351 | Supply and installation of 24 Port Gigabit Fiber Ethernet Access Layer 3 Switch with• 24 x SFP ports • 2 x 10GBASE-T ports • 4 x 10G SFP+ ports, Switching Capacity168Gbps ,125 Mpps Packet Forwarding Rate CPUARM7 800M , Packet Buffer Memory 2 MB ,MAC Address16K , ACLBased Jumbo Frames up to 9 Kbytes ,Switch should support • IEEE 802.3af • IEEE 802.3at ,Switch should supportStatic Route • RIP/RIPng • OSPFv2/v3, TemperatureWorking 0°C~50°C,Storage Temperature-40°C~75°C, Power Supply AC: 100~240VAC,Make: Cisco/HP/D-Link |
352 | Supply and installation of• 24 10/100/1000BASE-T PoE • 4 1G SFP , Switching Capacity56 Gbps,64-byte Max. Forwarding Rate 41.7 Mpps ,RJ 45 Console port,193 W PoE budget, Switch should support • IEEE 802.3i 10BASE-T Ethernet (twisted-pair copper) • IEEE 802.3u 100BASE-TX Fast Ethernet (twisted-pair copper) • IEEE 802.3ab 1000BASE-T Gigabit Ethernet (twisted-pair copper) • IEEE 802.3az compliance • Auto-negotiation • IEEE 802.3x Flow Control • IEEE 802.3z 1000BASE-X Gigabit Fiber ,MAC Address16K entries,Operating Tempreture -5 to 50 °C , storage -40°C~70°C, Power Supply AC: 100~240VAC.Make: Cisco/HP/D-Link |
353 | Supply and Laying of 6 Core Single Mode(OS2) Corrugated ECCS Armor, HDPE (UV) Sheathing, Theoxtropic gel filled OFC cable with 2 Nos steel music wire embedded in side sheathing as strengthening member for switch connectivity. Cable should be ROHS compliant and as per ANSI/TIA-568.3-D, Telcordia GR-20, IEC 60794-2/60794-3-10, ISO/IEC 11801, ISO/IEC 24702 complete on surface / recess / in existing pipe / open duct complete etc as required. in existing conduits.Shall be RoHS Compliant. OEM should be a member of BICSI India and should have acertified project management professional (PMI-PMP®) and a CDCP® / RCDD® on the OEM’s payroll sitting in India whose services can be utilized for this project. Make:R&M/3C3/Legrand |
354 | Supply and Installation of 6F Rack Mount Drawer Type LIU loaded LIU with SM LC adaptor plates, Pigtail, Spilce tray, cable holder and 4 nos of cable entry exist point with rubber gurment along with the LIU, SPCC Powder Coated, 2-Cut Out type, 1U etc complete as required. Shall be RoHS Compliant. OEM shall be ISO 9001:2015, ISO 14001:2015 and ISO 45001:2018 and should have its Manufacturing units, Components and Finished Goods Warehouse & R&D labs in India. Make:R&M/3C3/Legrand |
355 | Supply and Installation of 24F Rack Mount Drawer Type LIU loaded LIU with SM LC adaptor plates, Pigtail, Spilce tray, cable holder and 4 nos of cable entry exist point with rubber gurment along with the LIU, SPCC Powder Coated, 2-Cut Out type, 1U etc complete as required. Shall be RoHS Compliant. OEM shall be ISO 9001:2015, ISO 14001:2015 and ISO 45001:2018 and should have its Manufacturing units, Components and Finished Goods Warehouse & R&D labs in India. Make:R&M/3C3/Legrand |
356 | Supply and Installation of 1G SFP transceiver module Make: Cisco/HP/D-Link |
357 | Supply and Fixing of LC-LC Multimode OS2 (9/125) duplex, LSZH fiber patch cord having aprotective layer of metal braiding for LIU to switch connectivity. Patch Cord should have Blue Jacket with 1000 time mating cycle complete etc as required. Shall be RoHS Compliant. OEM shall be ISO 9001:2015, ISO 14001:2015 and ISO 45001:2018.(All necessary documents to be Attached Make:R&M/3C3/Legrand |
358 | IP SURVEILLIANCE system Supply, installation and commissioning of 4MP Dome/Bullet IR Network Camera (1/2.7" CMOS sensor, Mini. Pixel of 2688*1520 or higher video quality, frame rate of Up to 25fps, ·Min. illumination Color: 0.002Lux.Ultra 265, H.265, H.264 & MJPEg video compression, 2.8mm Fixed lens, ,physical ICR filter of both day and night, 30mtr IR Distance,120dB WDR ,ANR,ROI, 2 Streams Supported,support 512GBSD card,3D-DNR for noise reduction, BLC, ICR, EXIR, Built in Audio(MIC) supported, IP66,ONVIF ver 2.2 or higher, PoE IEEE 802. 3af inbuilt surge and lightning protection(UL/BIS, FCC, CEcertified.) with accessories as require..Make- Honeywell/Alcon/pelco/Axis |
359 | Supply and Installation of 64Ch 4K Network Video Recorder 8 sata ,each SATA support upto 18TB HDD, NVR should support more than 20% higher than the capacity of channel both on recording and Live view , Up to 12 Megapixels resolution recording,Synchronous Playback16CH, RAID0, RAID1, RAID5, RAID10. Supported, RS-232, RS-485, 2 × USB 2.0, 1 × USB 3.0,ALARM IN/OUT-16/4, Incoming bandwidth 640Mbps outgoing bandwidth 320Mbps, 2HDMI/2VGA. 2* 10/100/1000Mbps LAN port Make-honeywell/Alcon/pelco/Axis |
360 | 8TBStorage Capacity, Make: Seagate/ WD. |
361 | SITC of 55" LCD (3,840 x 2,160) TV with 350 brightness,10W+10W Audio Output, 178 (89/89) degree Viewing Angle,4K X-Reality PROVideo Processing,Pro settings,HDMI auto wake-up,Android,16GB Onboard Storage,Wi-Fi,MPEG1/MPEG2,RS-232C Control,HDMI inputs 3,1 Side Analog Audio Input,1 Digital Audio Output,2 USB Ports,1 Ethernet inputs. Make: Samsung/ LG / SONY. |
362 | Supply and laying of following size rigid PVC conduit pipe (medium ) through floor / wall / partition with GI spacer clamps or as directd.Rate to include for accessories - bends,sockets T"s etc. |
363 | 20 mm dia. |
364 | 25 mm dia. |
365 | 32 mm dia. |
366 | Supply, Installation, Testing & Commissioning of 19" Rack Mountable VOIP ready EPABX with initially equipped with200 IP Extensions, 99 IP Trunk, 8 Vocoder channels, 4 VMS channel, 8 Conference channels, 10UC clients,4 P&T ports & 4 analog extensions port through external Gateway.The system should have VoIP at its core i.e. VoIP modules should be mounted on the CPU itself. The system should support SIP/IP extensions and trunks over SIP protocol. It should be possible to support SIP Trunks and SIP/IP Extension with the single VoIP module. It should support up to 99 SIP trunks and 2100 SIP/IP users (SIP/IP Phone, Mobile softphones, UC Client). The system should TDM ports through Gateways. It should be possible to reach the maximum capacity of the system of 2100 IP users without any add-on CPU or chassis/hardware platform. VoIP should be Daughter-board module mounted on CPU. VoIP module(s) should support up to 550 concurrent VoIP channels without transcoding, 248 concurrent VoIP channels with transcoding, 99 SIP trunks and 2100 SIP/IP users (SIP/IP Phone, Mobile softphones, UC Client). Voicemail feature should be inbuilt in the system and should not require any additional hardware module. Voicemail feature should be available to all the users connected to the system without any license. The system should support atleast 21 concurrent Call Tapping and Conversation Recording. It should support minimum 50 concurrent IP-IP Video calls without using any VoIP Channel. The system should support SIP over TLS and SRTP to ensure VoIP call security over IP network. System should have two Gigabit Ethernet ports for LAN and WAN to separate out local and VoIP traffic on external network. System should have two external USB port to support various applications. The system should have built-in Auto-attendant facility and should be able to answer up to 64 calls simultaneously and should support dial-by-name. The system should support multi-lingual IVR in atleast 6 different languages in Auto-attendant. Detailed reports of all system parameters should be generated through the SMDR port of system. Varied type of open SIP Terminals such as IP Phone, SIP softphone, Mobile SIP Client and UC Client shall be supported. The manufacturer should also have UC Client application for Android and iPhone and on Windows PC so that the mobility can be extended for the smartphone users. System"s UC Client for PC should support 1000 DSS, 600 BLF and drag & drop conference. Preference would be given to the indigenous design manufacturer and made in India product. Preference would be given to the manufacturer having DSIR recognized R&D(MAKE: Syntel/NEC/Matrix/Alcatel) |
367 | Supply and Installation Of Display: 128 x 64 –pixel Graphical LCD (3.1 Inch), LED for Call and message wait Indication, Intuitive user interface with icons. Feature Keys: 3 Feature Keys : Headset, Mute , Hands-free speaker phone, 4 Context Sensitive Keys, 2 Line keys, Function such as navigation, Call Appearance , feature status. Volume Control Keys. Interface: 2 X RJ45 10/100/1000 Mbps Ethernet Ports, Power Over Ethernet (IEEE 802.3af), 1 x RJ9 Handset port, 1 xRJ9 Headset port, DC Power Jack. LED for Call & message wait indication, Intuitive user interface with Icon. Clear Voice: Codec: G.722, G.711(A/µ), G.729, G.726, G.723 DTMF: In-band, Out-of-band(RFC 2833) and SIP INFO,Full Duplex Speakerphone with VAD, CNG, AEC, AJB & AGC.Power Supply: Power on Ethernet (IEEE802.3af), 5VDC 2A. Secure Communications: Extended (Proprietary) SIP Protocol, TLS/SRTP for Voice Security.(MAKE: Syntel/NEC/Matrix/Alcatel) |
368 | Supply, Installation, Testing & commissioning of IP Phone with 2 x 10/100 Mbps LAN & PC Ports, Graphical LCD with Backlit, LED for Incoming/Ongoing Call, Mute, Hold.Add on 32 key module support, maximum key modules shall be supported, Should be possible to connect additional key modules up to 128 keys. Intuitive User Interface with Icons, Multiple Languages Caller ID with Name, Number, 45 or more keys including 4 Context Sensitive Hard Keys, RJ9 Handset Port, RJ9 Headset Port, 3.5 mm Headset Port. Installation: Wall Mount, Table-top, CE,FCC-15,RoHS Power over Ethernet (IEEE 802.3af), Power Consumption: 5W (Typical), Connector: DC Power Jack, 5VDC/600mA, Message wait Lamp, Ringer Lamp, Voice Mail, Call Pickup – Group and Selective, Paging, Mute, Call Hold, Do Not Disturb, Speed Dial, Hotline, Redial, Call Back, Auto Answer, Call Forward, Call Waiting, Call Transfer, Room Monitoring, Conference, Directory, Call Logs, Paging Dial-by-Name (MAKE: Syntel/NEC/Matrix/Alcatel) |
369 | Supply and Installation of 1KVAOnlineUPS single phase in & singlke phase out with inbuild isolation transformer smart Led display have been 30mtn backup time in complete as per the direction of engineer incharge. Make: Vertiv/Numeric/APC |
370 | Subhead- 4 (AUDIO SYSTEM):- Supplying, installation, testing & commissioning of 8 zone,voice alarm controller with USB, MP3 player (including 8zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required(Make-Honeywell/Bose/Bosch) |
371 | Supplying, installation, testing & commissioning of digital audio amplifier 500 Watt,operating at 240 Volt AC Supply complete as required. (Make-Honeywell/Bose/Bosch) |
372 | Supplying, installation, testing & commissioning of ceiling/wall mounted loud speaker, 15 Watt with enclosure complete as required(Make-Honeywell/Bose/Bosch) |
373 | Supplying and drawing of speaker cable Single pair, 2-core, 1.5 sqmmin existing conduits(Finolex/Legrand/eq.) |
374 | Supply ,installation ,testing & commissioning of30KVA/30kwUPS SYSTEM WITH suitable size battery bank, rated of battery ,IGBT based inverter system with inbuilt isolation transformer & automatic phase sequence correctorof 3ph in put to 3 ph output,415V,protection for fault by OV,UV,EF,GF,OC, model ofNumeric/ emersonreputed make A catogory, ISI marked as approved ) including supply of rack inverter stand with sufficient backup upto 60 minutes with all required accessories to complete the job including all connection as per direction of Engg.-in-Charge. Warrentee period of all accessories & component & systemmust be 2 years & compelete test certificate must be submitted along with upsincluding component list & SLD. |
375 | Supply Installation Testing and Commissioning of on grid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono / Poly Crystalline silicon solar cells, net metering facility ,necessary protections, earthing, mounted on Aluminium / GI structure of suitable strength with following components a complete aas arequired: a) Solar Photovoltaic Module of capacity 330Wp or above, manufactured in India, conforming to IS14286 / IEC61215, IS/IEC61730-Part-1,IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants /systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase , 4 wire, 50Hz +/- 2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree Celcious.The PCU shall adjust the voltage and frequency level to suit the Grid Voltage,frequency. c) Data Monitoring System complete with accessories.d)Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugsand other accessories etc. asarequired.e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/ conduit lugs and other accessories etc. asrequired. with all required accessories as requiredas per the direction of Engg-in-charge.Make-Kamal Solar/ EMMVEE/ Venus / Anchor/panasonic or equievalant reputed make & model A catogory, ISI marked as approved . The entire SOLARsystemshould be Replacement Warranty will be 5 years |
376 | Supply and Fixing of 2 Ton Split A.C Machine . (3 Star rating)(Copper)(Make: Carrier/Voltas/LG). |
377 | S/F of copper coolingpipe withcable and insulation |
378 | S/F of 130 to 280 volt 5KVA Stabilizer (Make - V-Guard/ Microtec/Leotonics/ Alfa/ L. Power) |
379 | S/F of MS stand for outdoor unit of split AC machine(Wall mounting) |
380 | PUMPS AND APPARATUS:- Supplying, installation, testing and commissioning of Electric Motor DrivenPressurization Terrace Pump having discharge of 900 LPM at 35 Mtr head complete with Pump Set, Electric Motorsuitable for operation on 415 V ,3 ph, 50 c/s AC supply , Base Frame. Make-Wilo/KSB/Kirlsokar |
381 | Supply, installation, testing and commissioning of Floor/Wall mounted sectionalised, front operated top entry dust and vermin proof M.V.Panel Boards suitable for operation at 415V, 3 phase, 4 wire, 50Hz distribution system fabricated out of 2.0 mm thick CRCA sheet, insulated busbar with heat shrienkable PVC sleeve, base frame, complete with all accessories including interconnections, earth bus etc as required.Make of switchgear -Legrand/Schneider/Siemens |
382 | PIPE & VALVES ETC.:-Supply,Installation,Testing & Commissioning of "C" Class heavy duty MS pipe (as per IS 1239 upto 100 mm NB and IS 3589 for above 100 mm 6.33mm thick) with flanges and fitting such as bends, tees, reducers, rubber insertions and galvanized nuts and bolts of following size on surface along wall / shaft with MS bracket, suspended from ceiling/ beam with suspenders duly painted with two coats of primer and finished with enamel paint of approved colour laid through pipe or in trench after wrapping with hassen cloth after applying coal tar primer as required as per direction of Engineer-in- charge.Make-Sail/Jindal/TATA 100mm NB |
383 | 80mm NB |
384 | 25 mm NB |
385 | Providing, fixing, testing and commissioning of following size manually operated hand lever type cast iron double flanged slim seal wafer type Butterfly valves with EPDM iron disc as per IS-13095 having pressure ratting PN -1.60 including fixing the same with supply of required jointing materials like rubber insertion, MS nuts & bolts, paint etc. and testing the joints with required water pressure etc. all complete as per specification & direction of E.I.C.Make-Zoloto/Kartar/Kirloskar 100mm NB |
386 | Providing, fitting & fixing of following size cast irondouble flanged type dual plate Non return Valve as per IS- 5312 (Part 1): 2004 with ISI mark of pressure ratting PN-1.60 including fixing the same with supply of required jointing materials like flanges, rubber insertion, MS nuts & bolts, paint etc. and testing the joints with required water pressure etc. all complete as per specification & direction of Engineer-in-charge. Make-Zoloto/Kartar/Kirloskar 100mm NB |
387 | Supply,Installation,Testing & Commissioning of Pressure gauge of 0-16 Kgf/sq.cm. range with cut-off bronze ball valves of suitable size with all accessories as per direction of Engineer-in-charge.Make-H.Guru/G.Guru |
388 | Supply,Installation,Testing & Commissioning of Pressure Switch with cut-off bronze ball valves with integral strainer & flare nut (mixed ends) of suitable size with all accessories as per direction of Engineer-in-charge.Make-Indfoss/Grundfoss |
389 | Supply,Installation,Testing & Commissioning of stainless steel strainer fabricated out of 1.6 mm thick stainless steel sheet Y Stainer with 3 mm dia hloes with stainless steel flange as required. Make-Zoloto/Kartar/Kirloskar100mm NB |
390 | DOWN COMER SYSTEM:- Supply,Installation,Testing & Commissioning of Stainless steel Hydrant Valve / Landing valve, of 63 mm NB size, type-A, single headed , oblique type, as per IS :5290/93 and as per direction of Engineer-in-charge. Make-Minimax/Newage/Fireshield |
391 | Supply,Installation,Testing & Commissioning of SS short branch pipe with 63 mm male inlet and 19 mm outlet nozzle, as per IS:903 and as per direction of Engineer-in-charge. Make-Minimax/Newage/Fireshield |
392 | Supply,Installation,Testing & Commissioning of 63 mm NB and 15meter long RRL Fire Hose fitted with63mm intstantaneous stainless steelmale & female SS coupling, complete by GI wire binding for Internal Hydrant as per direction of Engineer-in-charge.Make-Minimax/Newage/Fireshield |
393 | Providing supply & fixing of MS Hose Box for of suitable size(750X600X250mm) to accomodate 2 nos. of 15/ 1 no of 30 mtr long fire hose and a branch pipe, wall mounted type as per direction of Engineer-in-charge.Make-Minimax/Newage/Fireshield |
394 | Supply,Installation,Testing & Commissioning of Swinging pattern wall fixing first aid hose reel made from MS sheet and waterways and moving parts with rubber hose of 20 mm dia. and 30 mtrs. long with ABS(Plastic) shut-off nozzle as per IS: 444/IS: 12585 Type-I., complete with all accessories as per direction of Engineer-in-charge.Make-Minimax/Newage/Fireshield |
395 | Providing, fitting and fixing of C.I. 25 MM single air relief valve with stop cock confirming to IS:14845/2000 with ISI mark for water works purpose including fixing the same with hydrant riser including testing & commissioning the system etc. all complete as per approved specification & direction of Engineer-in-charge. |
396 | Providing, fitting & fixing of 2-Way GM fire brigade connection consisting of 63 mm dia instantaneous type male couplings with built-in check valves, 150mm dia flanged outlet complete with bolts, nuts and rubber insertions confirming to IS:904 with ISI mark including testing & commissioning the system etc. all complete as per apporoved specification & direction of EIC. Make-Zoloto/Kartar/Kirloskar |
397 | EXTINGUISHER SYSTEM:- Supply,Installation,Testing and Commisioning of ISI marked (IS:2878) Fire Extinguisher ,Carbon di-oxidetype capacity 4.5kg with all accessories (Ever safe/Fire shield) |
398 | Supply,Installation,Testing and Commisioning of ISI marked (IS:2878) Fire Extinguisher ,ABC type capacity 6kg with all accessories (Ever safe/Fire shield) |
399 | Fire buckets (FILLED WITH SAND) round bottom type enamel painted, white inside & Red out side and Letter "FIRE" in black out side and handle with mounting bracket. |
400 | AUTOMATIC FIRE ALARMING SYSTEM:-Supplying installation testing and commissioning of Microprocessor based Addressable Fire Alarm Control Panel(1 LOOP)Single Loop Control Panel, 230Vac, 2 sounder circuits. Supports260 x 390 x 147mm (H x W x D) Network up to 16 loops (16x1 loop panels, 8x2 loop panels, 4x4 loop panels or any mix up to max 16 loops) True peer-to-peer and fault tolerant network for high system reliability BS5839 part 1 compliant network Disable all relays Easy 5 key-press set-ups Large blue LCD display Supports USB upload/download Alpha-numeric style keypad and navigation keys Option to upload a company logo 160 zone compact mimic support Panel buzzer ‘mute’ in engineering mode Up to 72-hour standby.(Make: Morley/ Siemens/Bosch. |
401 | Supply, Installation, Testing & commissioning of Addressable Manual Call Point soft addressable type with in built fault isolator asrequired.(Make: Morley/ Siemens/Bosch. |
402 | Supply, Installation, Testing & commissioning ofAddressable Loop Powered Hooter cum Strobe (sound output of minimum 90db) cum strobe (strength of light 10cd) complete with inbuilt isolator as required.(Make: Morley/ Siemens/Bosch. |
403 | Supply & Fixing of 2 core 1.5 sq.mm, multi strand, copper conductor, FRLS (Fire Retardent Low Smoke)-PVC insulated GI Screened Armoured cable with saddle and required accessories.& Power Cable. |
404 | SIGNAGES:-Providing and fixing the signages "In case of fire pull down- with Manual call point symbol ". Size 6" x 6" |
405 | Providing and fixing the signages "with Fire Extinguisher". Size 6" x 6" |
406 | Providing and fixing the signages "Main fire alarm panel." Size 4" x 12" |
407 | Providing and fixing the signages"Assembly point - with symbol ( A2 Size)" - Size 12" x 12" |
408 | Providing and fixing the signages"Entry/Exit".Size-8"x12". |
409 | Providing and fixing the signages"Arrow with left and right indecation".Size-8"x12". |
410 | Providing and fixing the signages"Stair case with left and right indecation".Size-8"x12". |
411 | EXTERNAL ILLUMINATION :- Supply ,Installation testing commissioning of elegant look Panasonic single arm by 1x 90 W LED street light having die cast aluminium housing with toughened glasshaving lumenoutput of 14500 or more (As per LM 79 report of third party NABL lab) ,IP 66 protection or more , LED street lightmodel will be videPanasonic/similar modelofof LT /Wipro/PHILIPS/ Orient/ Havells or its equivalent of Philips/LT/WIPRO or equievalant reputed make & model A catogory, ISI marked as approved, with proper model make having warrantied for a period of 5 years .The luminaire to be installed in 9 mtr long GI hot dip galvanized pole of Valmount/Transrail/RR/UTKASH /Utkal Galvanizer make equievalant make with proper model complete with SA bracket internal JB with 4 way connector and MCBas per the pole drawing and direction of EIC against which inspection mat take place.It should be installed after making proper size RCC foundation by considering RCC foundationby using M20 grade RCC & Fe 415 grade reinforcement and fixing the 4 nos. En 8 grade J type fdn bolts in the foundation. The luminaire needs to be wired with 3 c 1 sq mm wire from JB as per the direction of Engg-in -charge. |
412 | Supplying, Erection, Fixing, connection & testing of Panasonic 40 LED GATE Light of Panasonic/similar modelofof LT /Wipro/PHILIPS/Orient/ Havells or equievalant reputed make A catagoryISI marked as approved maintenance free having 2 years warrantyG.I P ipewith braket including MCB box & including with foundation as per the Drawing for inspection as required & as perdirection of Engg.-in-Charge. |
413 | Supply of materials and installation of pipe earth electrode made out of 50mm dia class B G.I. pipe of 3.0 metre long with arrangements for fitting/ terminationofG.I. flat / wire withG. I. nutbolts& washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.The entire earthing systemshould be Replacement Warranty will be 5 years |
414 | Providing and fixing 8 SWG (4 mm) dia copper wire on surface or in recess for loop earthing along with existing surface / recessed conduit as required. |
415 | Providing and fixing 25mm x 5 mm copper strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
416 | Supplying & Erection of hot dipped galvanized 9 mtr height octagonal pole with 1 mtr long (approx) GI bracket in approved design with 200 mm x 200 mm x 12mm GI base plate, 450 mm long "J" type GIfoundationboltswith with integral control gear having Bakelite sheet completewithDINrail,6AmpSP"C"typeMCB, cable entry pipe of 50mm HDPE pipe in foundation etc in complete as per the direction of engineer incharge. |
417 | Supplying and laying of one number PVC insulated armoured and PVC sheathed XLPEAL. conductor power cable of 1.1 KV gradePOLYCAB/FINOLEX/HAVELLS or equievalant reputed ISI MARKED MAKE of following size cables as per direction of Engg.-in-Charge.Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials3.5core x 35 sq mm |
418 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 25 SQ. MMdirect in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
419 | Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. 3.5 core x35sq mm |
420 | Aluminium alloy tubular bimetallic heavy duty cable socket. 16 mm |
421 | S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type MCB ENCLOSUREmade out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed asG.A drawing. (FOR USE) with 20A TPN MCB 01 NOLegrand/Schneider/Siemens or equievalant make & model as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 2 years ofacceptance of materials |
422 | Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials |
423 | Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete withfitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials50 mm dia |
424 | S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type timer panel with 32A 4P MCB ,40A TP CONTACTOR ,TIMER with 15 nos 10A SP MCB C as per direction of Engg.-in-Charge. .(Equievalant modeleach item of Legrand/Schneider/Siemens or equievalant make & model)Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for 2 years after acceptance of materials. |
425 | P.H. WORK Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor c-pvc pipes and pipe fittings of the following nominal bore with clamps including making good the wall, ceilingand floor all complete as per specification and direction of the Engineer in charge. 20mm dia "C" PVC pipe In Ground Floor |
426 | In First floor |
427 | In 2nd floor |
428 | In 3rd floor |
429 | In 4th floor |
430 | 25mm dia "C" PVC pipe In Ground Floor |
431 | In First floor |
432 | In 2nd floor |
433 | In 3rd floor |
434 | In 4th floor |
435 | 32mm dia "C" PVC pipe In 1st Floor |
436 | In 2nd floor |
437 | 40mm dia "C" PVC pipe In 3rd floor |
438 | In 4th floor |
439 | 50mm dia "C" PVC pipe |
440 | Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge. 250mmthick wall In Ground Floor |
441 | 250mmthick wall In 1st Floor |
442 | 250mmthick wall In 2nd Floor |
443 | 250mmthick wall In 3rd Floor |
444 | 250mmthick wall In 4th Floor |
445 | Supplying all materials, labour, T&Pand cutting hole in R.C.C floors, roofs, etc upto 19 cm thickfor passing G.I. Pipes / P.V.C pipes and fittings etc and repairing the holes afterinsertion of pipes etc with cement concrete (1:2:4 ) including finishing complete so as to make it leak proof as per direction of theEngineer in charge. GF |
446 | In 1st floor |
447 | In 2nd floor |
448 | In 3rd floor |
449 | In 4th floor |
450 | Supplying allmaterials, labour, T&P and cutting grooves in pucca floors and walls for takingGI/ PVC pipes and making good the damages as per the direction of the Engineer in charge. In Ground Floor floor |
451 | In 1st floor |
452 | In 2nd floor |
453 | In 3rd floor |
454 | In 4th floor |
455 | Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge. 15mm dia CP two way bib cock(CON-CHR-041KN) |
456 | 15 mm dia CP S.B. Bib cock(CON-CHR-037KN) |
457 | 15 mm dia CP L.B. Bib cock(CON-CHR-107KN) |
458 | 15mm dia CP angle stop cock(CON-CHR-053KN) |
459 | 20mm dia CP Con. stop cock (CON-CHR-089KN) |
460 | 15mm dia CP flange |
461 | 15mm Cp extention piece |
462 | 25mm brass full way valve |
463 | 32mm brass full way valve |
464 | 40mm brass full way valve |
465 | 50mm brass full way valve |
466 | 125mmdia C.P.grating |
467 | 15mm dia CP hand shower with reebit cleaning system (ABC chrome plated-Jaquar make-HSH-CHR-85537) |
468 | 600mm X 125mm C.P glass shelf (ACN -CHR-1171N) |
469 | CP towel rail (25 mm)(ACN-CHR-1111N) |
470 | 15mm dia C.P Pillar cock(CON-CHR-021KN) |
471 | C.P towel ring(ACN-CHR-1121NMI) |
472 | CP Soap dish Holder (ACN-CHR-1131N) |
473 | Supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge. 10 litres capacity pvc low level cistern (Slimline-white) |
474 | RCC OH tank in 5th floor 1No I/S:(7.15x2.70x1.25)Supplying all materials, labour, T&P and providing cement concrete (1:1.5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. In 5th floor |
475 | Supplying all materials, labour, T&P and providing M.Sreinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In Fifth floor |
476 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge R.C.C floor and roof slabs, landings, balconies, projecting sunshades and chajjas up to4.30m height fifth floor |
477 | R.C.C beams, columns, girder and bressmer etc--In G.F |
478 | Supplying all materials, labour, T&P and providing 6mm thick cement plaster (1:4) to RCC surfaces finished smooth including closed deep chipping and slurry tratment including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In 5th floor |
479 | Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In 5th floor |
480 | Supplying all materials, labour,T&P and providing 25mm thick grading concrete (1:2:2) on roof slab with 6mm size hardgranite chips on new work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge sixth floor |
481 | Supplying all materials, labour, T&P and distempering two coats to walls with distemper of approved shade on new work to give an even shade etc all complete as per specification and direction of the Engineer in charge |
482 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricantby non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge 110mm dia U-PVC SWR pipes(Supreme/Ashirvad) |
483 | 110mm U-PVC door Tee |
484 | 110mm U-PVC plain Tee |
485 | 110mm U-PVC door bend |
486 | 110mm U-PVC plain bend |
487 | 110mm dia U-PVC off set |
488 | 110mm dia U-PVC "P" trap |
489 | 110mm dia U-PVC cowl |
490 | 110mm dia U-PVC clamp |
491 | 50mm dia UPVC class-IV pipes |
492 | Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI/PVC SWR pipes and fittings including making good the damages etc all completeas per PH specification and direction of the Engineer in charge 250mm to 375mmthick wall |
493 | Supplying all materials, labour, T&Pand cutting hole in R.C.Croofs,cornice, etcfor passing H.C.I Pipes /U.P.V.C pipes and fittings etc and repairing the holes afterinsertion of pipes etc with cement concrete (1:2:4 ) including finishing complete so as to make it leak proof as per direction of theEngineer in charge. |
494 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C pan) with integral ‘P’or ‘S’ trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge E.W.C. with ‘S’ trap plain with seat cover(Parryware/Cera/ Nycer Make) |
495 | Supplying all materials, labour, T&P and fixing glazed earthenware squatting plate with integral longitudinal flushing pipe including embedding the plate in 25mm cement mortar (1:8) laid over 150mm cement concrete (1:5:10) using 40mm hard granite metal all complete as per specification and direction of the Engineer in charge Squatting urinal (Parryware make) |
496 | Supplying all materials, labour, T&P and fixing bowl pattern urinal of the following sizes including connecting the urinal with 32mm dia pvc waste pipe 910mm long by means of white lead mixed with chopped hemp, fixing 32mm dia CP dome waste, 15mm dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc all complete as per specification and direction of the Engineer in charge. Half stall urinal (Jaquar)URS-WHT-13261 |
497 | 15mm CP spreader |
498 | 32mm CP doom waste |
499 | Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps(Plaza make) capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste,etc all complete as per specification and direction of the Engineer in charge Counter top basin 560x455 (Parryware make) white |
500 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge Big size Mirror |
501 | Matrix Set -1 (WB 65 x 35 with one pair mounting brackets, EWC & Cistern complete with fittings & seat cover, one no hinged rail 76 cm and five nos of grab rails 60 cm) |
502 | Supplying all materials, labour, T&P and providing brick work with Fly Ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance± 8 percent in cement mortar (1:3) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In foundation and plinth |
503 | In first floor |
504 | In second floor |
505 | In third floor |
506 | In fourth floor |
507 | Supplying all materials, labour, T&P and providing cement concrete (1:1.5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. In ground floor |
508 | In first floor |
509 | In second floor |
510 | In third floor |
511 | In fourth floor |
512 | Supplying all materials, labour, T&P and providing M.Sreinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor |
513 | In first floor |
514 | In second floor |
515 | In third floor |
516 | In fourth floor |
517 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge R.C.C floor and roof slabs, landings, balconies, projecting sunshades and chajjas up to4.30m height |
518 | In Ground floor |
519 | In 1st. Floor |
520 | In 2nd Floor |
521 | In 3rd. Floor |
522 | In 4th. Floor |
523 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor |
524 | In first floor |
525 | In 2nd Floor |
526 | In 3rd Floor |
527 | In 4th Floor |
528 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge 12mm thick CP (1:4) on bw- In gf |
529 | In First floor |
530 | In 2nd Floor |
531 | In 3rd Floor |
532 | In 4th Floor |
533 | Providing & applying water proofing treatmnt (Twor Component glass fibre reinforced specially formulated acrylic modified , cementitious elastic coating system) using Sika Top Seal 109 hi & Sika Fab-1 or equivalent(Glass fibre cloth) @3 Kg/Sqmtr. before one coat of Sika Top Seal 109 high or equivalent Primer @ 200 gm/sq.mtr over the cleaned RCC Horizontal Surface & Outer retaining wall etc including the cost of all materials, cost of labour, conveyance, taxes, T & P etc . all complete as per the direction of Engineer-in-Charge. In 1st.floor |
534 | In 2nd Floor |
535 | In 3rd Floor |
536 | In 4th Floor |
537 | Fitting andfixing vetrified tiles Kajaria onfloors or steps & landing on 25mm. thick bed of cement mortar (1:1) jointed with neat cement slurry mixed with pigment to match the shades of the tiles includingcost conveyance, royalities and taxes etc. all complete as per direction of Engineer in charge. (Ceramic floor tiles of premium grade Somany Geostone Mistmake of size 600x600mm to be pre-approved by the Engineer in charge) In Ground Floor |
538 | In First floor |
539 | In 2nd Floor |
540 | In 3rd Floor |
541 | In 4th Floor |
542 | Supplying all materials, labour, T&P and providing granite tiles in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles etc. complete as per direction of the Engineer in charge. G/F |
543 | In 1st. Floor |
544 | In 2nd Floor |
545 | In 3rd Floor |
546 | In 4th Floor |
547 | Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles etc.complete as per direction of the Engineer in charge. (Ceramic wall tiles of premiumgrade Somany Daino Light(Glossy) make size 300 x 600 special plain / printed series to be pre-approved by the Engineer in charge) In ground floor (inside/outside) |
548 | In First Floor: |
549 | In 2nd Floor same as Cp |
550 | In 3rd FloorSame as CP |
551 | In 4th Floor Same as Cp |
552 | Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finishstructural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material,The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre"s standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. |
553 | Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigmentscomplete in all respect as per specification and direction of the Engineer in charge |
554 | Supplying all materials, labour, T&P and distempering two coats to walls with distemper of approved shade on new work to give an even shade etc all complete as per specification and direction of the Engineer in charge- In Ground floor |
555 | In First floor |
556 | In Second floor |
557 | In Third floor |
558 | In Fourth floor |
559 | Providing fitting, fixing of Al. door with OEL anodized Al. door section of 9202 as vertical member, 9201 as top member and 9200 as bottom and middle member and 12mm thick pre-laminated board fixed on door frame by means of tapered clip No. 4660 and the frame to be completed by means of jointing angle No. 1855 including all cost of labour,T&P , hire charges of drilling machine,labour charges etc. complete. |
560 | For DA toilet= 5x1x1.50x2.00= |
561 | Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:1.5:3) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, fly ash bricks in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI/P-trap gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge Inside size 250mmx250mm |
562 | Supplying all materials, labour, T&P and constructing inspection chamber of the following sizewith cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge Inside size 760mmx760mmx460mm |
563 | Supplying all materials, labour, T&P and constructing man hole chamber of the following sizewith cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class K.B brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge Inside size 910mmx910mmx910mm |
564 | Supplying all materials, labour, T&P and providing 450mm dia x 50mm thick RCPC man hole cover in cement concrete (1:2:4) using 12mm size h.g chips, placing the cover on the man hole/ inspection chamber and finishing smooth all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification anddirection of the Engineer in charge R.C.P.C. Cover(20"/22" round Man hole cover) |
565 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with precast RCC rings joined loose, gravel backing in the rear of well steining, precast RCC cover slab in cement concrete (1:1.5:3) using 12mm size hg chips fitted with iron lifting handles including cutting hole in the rings for inlet pipe,earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge Brick masonry soakway pit 1.40m dia x 2.00m deep |
566 | RCC rings soakway pit 1.22m dia x 2.10m deep |
567 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasingincluding concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge. 110mm dia u-pvc pipe alround concrete |
568 | 160mm dia u-pvc pipe alround concrete |
569 | Construction of 100 users RCC septic tank- (I/S size-5.70mx2.10mx2.40m)-30cm wide wall Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of theEngineer-in-Charge. |
570 | Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general. |
571 | Supplying all materials, labour, T&P and providing shoring and shuttering foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per direction of the Engineer in charge. |
572 | Supplying all materials, labour, T&P and providing dewatering water from pit using 5 HP disel pump set etc.all complete as per specification and direction of the Engineer in charge |
573 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer incharge. |
574 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor |
575 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge R.C.C floor and roof slabs, landings, balconies, projecting sunshades and chajjas up to4.30m height |
576 | R.C.C beams, columns, girder and bressmer etc--In G.F |
577 | Supplying all materials, labour, T&P and providing M.Sreinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor |
578 | Supplying all materials, labour, T&P and providing cement concrete (1:1.5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. In ground floor |
579 | Supplying all materials, labour, T&P and providing brick work with Fly Ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance± 8 percent in cement mortar (1:3) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In foundation and plinth |
580 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor |
581 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In Ground floor |
582 | Supplying all materials, labour, T&P and providing 6mm thick cement plaster (1:4) on RCC work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor (inside) |
583 | Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor (inside) |
584 | Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls ofman hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge. Making MS step iron in 20mm diameter MS steel bars |
585 | Supplying all materials, labour, T&P and providing, fitting and fixing U-PVC SWR Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification and direction of the Engineer in charge 160mm U-PVC plain Tee |
586 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge |
587 | (Sinking of 150mm size tube well through hand boring( water jet) method) Suplying all materials, labour, T&P and setting up boring equipments including erection of suitable staging for installation of the required size of tube well, dismantling and removing the same after complection of the work, including transportation of the boring equipments, cleaning and levelling the site, excavation of mud pit, channels etc, levelling of site all complete as per direction of Engineer in charge |
588 | Supplying all labour, T&P and transporting the boring pipes, top casing, grouting pipes, PVC pipes and fittings, PVC well screens, cement, bentinite and gravels etc to the worksite including loading and unloading etc all complete as per direction of the Engineer in charge. |
589 | Supplying all labours, T&P and drilling pilot bore not less than 102mm dia, without casing pipes in all kind of soils and rocks for the following depths excluding supply of necessary boring pipes including supply of necessary cutting equipments, extra sockets ( whenever required) etc and withdrawing the boring pipes, washing and keeping the bore logging if required all complete as per direction of Engineer in charge Drilling pilot bore from 0 to 360 metres |
590 | Supplying all labour, T&P and reaming the pilot bore to the following sizes and depth without casing pipes including withdrawing the boring pipes, washing the bore by means of pipe cylinder etc all complete as per direction off Engineer in charge. Reaming 100mm to 150mm dia from 0-360 mtr |
591 | Reaming 150mm to 200mm dia from 0-360 mtr |
592 | Reaming 200mm to 300mm dia from 0-360 mtr |
593 | Supplyimg all labour, T&P and jointing materials & lowering the 300mm dia top casing pipes into the position and removing the same after all complete as per direction of Engineer in charge From 0-360 mtr |
594 | Supplying all labour, T&P and jointing materials and lowering the pvc casing pipes, fittings and well screens in position, including fitting and fixing of centraliser, cutter plug and washing the bore all complete as per direction of Engineer in charge 150mm dia PVC casing pipe from 0 to 360 metres |
595 | Cost of 150 mm dia PVC ASTM pipe(sch-80) |
596 | Cost of 150mm dia Slott Cutting |
597 | 150 mm dia C.I.end/top cutter plug |
598 | Cost & Conveyance of bentonite powder |
599 | Supplying all materials, labour, T&P and packing the bore with washed gravel of river shingles of required size and specification around the well screen and pipe etc all complete as per the direction off the Engineer in charge. Labour charges |
600 | Cost and Conveyance of gravel |
601 | Supplying all materials, labour, T&P and packing the bore with river sand over the gravel pack all complete as per the direction of the Engineer in charge. Labour charges |
602 | Cost and Conveyance of sand |
603 | Supplying all labour, T&P including developing the tube well with compressor ( supplied by contractor ) continuiously worked till clear & adequate discharge is obtained from the tube well including supply and use of necessary equipments and labour as per direction of the Engineer in charge. Labour charges |
604 | Supplying all materials , labour, T&P and providing & fixing to wall or ceiling and floor pvc pipes confirming to ASTM-D & pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction. 32mm dia HDPE pipe |
605 | 32mm dia UPVC ASTM pipe |
606 | Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submerisble electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trail running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge 1.50H.P single phase submersible pump set (KP4-03215 pumpset CP)Kirloskar/Crompton/CRRI make |
607 | DOL Control panel |
608 | 40mm dia steel short piece |
609 | Well cap |
610 | 50mm size CI bracket |
611 | 2.50 sqmm flat cable |
612 | Steel rope with cover |
613 | 20mm dia rigid UPVC pipes |
614 | Supplying all materials, labour, T&Pand providing & electrification to submerssible pump sets and service connection including fitting fixing of electric board & Switch etc all complete as per direction of the Engineer in charge. |
615 | Supplying all materials, labour, T & P and constructing Bore well protection chamber of the inside size 650x650x1000 hight with cement concrete (1:3:6) using 40mm size hard granite metal on foundation, 1st class Fly ash brickwork in cement mortar (1:3), with base cement concrete (1:2:4) using 12mm size h.g. chips, 12mm thick cement plaster (1:4) inside and outside, RCC cover slab in (1:1.5:3) using 12 mm size h.g. chips, earthwork in excavation in all kind of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction pof the engineer in charge. |
616 | Supplying, fitting, fixing up window (sliding type) made up aluminum Section 151-154,151-155, as windows frame section No. 151- 155, 151-153 and 151-167 as shutter frame with 5mm thick black glass as panel fitted with rubber beading including locking arrangement including all fitting including cost of materials all taxes labour, T&P etc.complete as per direction of Engineer-incharge. |
617 | Construction of 100000 Liters RCC Under ground Reserver of Inside size- 10.00x5.50x2.10m Earth work in All kinds of soil and gravels mixed with stone and boulder not exceeding 0.014 Cum in volume within 50m initiallead and 1.5 m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per specification approved by the Department. |
618 | -do- with Ist additional depth of 1.50 m over the initial lead and lift |
619 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer incharge. |
620 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
621 | Supplying all materials, labour, T&P and providing cement concrete (1:1½:3)with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
622 | Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage. |
623 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete in ground floor. |
624 | RCC floor roof, chajja etc |
625 | RCC Beam, Column, wall etc |
626 | RCC Plinth bend/ Raft |
627 | Supplying all materials, labour,T&P and providing 6mm thick cement plasster (1:4) overCC workincluding watering curring and conveyance of all materialsto site. |
628 | Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site. |
629 | Supplying and fitting and fixing stainless steel 34 grade in said rail using 5mm dia 2mm thick circular pipe and lalustrade 32mmx32mmx2mm at the rate of mtr.Center to center and square pipe 32x32x2mm below including welding with stanless steel elect rod and fixing with necessary accessories etc.complete as per direction of the Engineer-in-charge. |
630 | Providing fitting and fixing RCPCcoveretc complete as per direction of Engineer-in-charge |
631 | Supplying all materials, labour, T&P and providing shoring and shuttering foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per direction of the Engineer in charge. |
632 | Sides - 2x(10.50+6.00)x2.10= |
633 | De-watering |
634 | 10 daysx 2hours x 5.0 HP pump |
635 | Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submerisble electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trail running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge 5 H.P three phase 3 stage head range 30 to 54 metres, discharge 155 to 110L.P.M with outlet dia of 32mm |
636 | DOL Control panel |
637 | 2.50 sqmm flat cable |
638 | 20mm dia rigid UPVC pipes |
639 | Supplying all materials, labour, T&Pand providing & electrification to submerssible pump sets and service connection including fitting fixing of electric board & Switch etc all complete as per direction of the Engineer in charge. |
640 | 50mm diaC-PVC Pipes |
641 | 40mm dia C-PVC ball valve.(Ashrivad make) |
642 | 40 mm brass ball cock with ball |
643 | 50mm dia GM horizontal check or non-return valve |
644 | Supplying all materials , labour, T&P and providing & fixing to wall or ceiling and floor pvc pipes confirming to ASTM-D & pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction. 40mm dia HDPE pipe |
645 | Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 120 PSS UV of size 750x570x1350mm height with water storage capacity 120 liters along with 3 nos of faucets 2 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all completeas per approved drawing,specification and direction of the Engineer in charge. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy