Tender For Rate Contract For Call Basis Servicing And Repairing Of Acs Units Of Various Exchanges Btss In Ba Dehradun, dehradun-Uttarakhand

Bharat Sanchar Nigam Limited-BSNL has published Tender For Rate Contract For Call Basis Servicing And Repairing Of Acs Units Of Various Exchanges Btss In Ba Dehradun. Submission Date for this Tender is 06-04-2024. Building Work Tenders in dehradun Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

43060692
Tender For Rate Contract For Call Basis Servicing And Repairing Of Acs Units Of Various Exchanges Btss In Ba Dehradun
Open Tender
Indian
Uttarakhand
dehradun
06-04-2024

Tender Details

Tender For Rate Contract For Call Basis Servicing And Repairing Of Acs Units Of Various Exchanges Btss In Ba Dehradun- 1 Visit Charges To Attend The Faultof Acuniton Call / Complaint Basisatte / Bts Sites I / C Analysis Of Fault, Minor Repiring , And Making The Detailed List Of Defects And Estiimation Of The Same I / C To & Frotransportation Chargesetc. Complete As Required. 2 In Dehraduncity 3 In Rural Area In Dehradun Up To 60 Km 4 In Rural Hill Area In Dehradun Ba 5 Generalservicing Of All Type & Capacitywac / Sac / Hshf / Water Cooler Units At Site Of Different Make And Model I / C Removing From Existing Position If Reqd, Dismantling Of Faulty Parts, Cleaning The Air Filter, Cleaning The Condenser And Evaporator Coil With Help Of Water Pressure Spray Gun , Lubrication Of Moving Parts, Complete Checking, Testing And Minor Faults Rectification I / C Replacement Of Knobs / Wiring Kit ( If Required ) , Setting Of Thermostat, Preparing Report Including Tightness Of All Electrical Connections From Sp Mcb In Db To Dp Mcb / Plug & Socket To Stablizerto Ac Unit Etc As Reqd. 6 In Dehraduncity 7 In Rural Area In Dehradun Up To 60 Km 8 In Rural Hill Area In Dehradun Ba 9 Charging Of Refrigerant Gasr-22 / R-32 / 410 Up To Specified Pressure ( As Per ManufacturerS Recommendation ) In Following Capacityac Units And Pressure Testing By Nitrogen, Vaccumisation For2 Hours, Purging With Gas And Testing Commissioning Of The Ac Unit Etc. As Reqd. Note: One Job Consists Of Charging Of Gas In One Compressor I.E.. One Complete Air Conditioning Circuit Only. 10 1.5 Tr 11 2.0 Tr 12 Replacement Of The Following Items / Accessories In The Existing Wac / Sp Ac / Water Coolerunits Of All Makes In Place Of Faulty / Unserviceable Parts I / C Dismantling Of The Faulty, Fixing The New Item And Testing, Connection Etc. Complete As Reqd. 13 120-140 Mfd Starting Capacitor Aluminum Case 14 40 / 50 Mfd Running Capacitor Aluminum Case 15 4Mfd Fan Motor Capacitor Aluminum Case 16 Wac Blower / Wac / Condenser Fan Blade 17 Starting Relay 18 Pcb For Split Ac 1.5 Tr / 2Tr 19 Pcb For Inverter Type Split Ac Indoor Unit 20 Pcb For Inverter Type Split Ac 1.5 Tr-For Out Door Unit 21 S / F Ofblower / Condenserfan Motor For 1.5 / 2 Tr Window / Split A.C / Water Coolerunit In Lieu Ofunservisiblemotor I / C Connection Etc As Required. 22 Provision Of Top Up Of R-22 / R-32 / 410Gas In Existing All Type Window A.C / Split A.C / Units, Flushing, Testing Etc. As Required. 23 Rewinding Of Existingall Type Blower / Condenser Fan Motor For 1.5 / 2 Tr Window / Split A.C Unit / Water Cooler I / Creplacement Of Bush I / C Oiling , Greasng Etc As Required 24 P / F 12Mm Thick Exterior Grade Particle Board For Acunit Forsupporti / C Fixing The Samewithscrew , Complete Etc. As Reqd. 25 Replacement Of The 1.5 Trrotarytype Compressori / C Dismantling Of The Existing Compressor From Site, To And Fro Transportation Chargesand I / T / C Of Compressor In Existing Wac / Split Acetc Complete As Required.Note: The Agency Has To Provide One Year Guarantee For Every Replaced Compressor Along With Test Certificate / Invoice Of Purchase From Authorized Dealer, Faulty Compressor Shall Be The Property Of Contractor. 26 Replacement Of The 1.5 Trreciprocating Type Compressori / C Dismantling Of The Existing Compressor From Site, To And Fro Transportation Chargesand I / T / C Of Compressor In Existing Wac / Split Acetc Complete As Required.Note: The Agency Has To Provide One Year Guarantee For Every Replaced Compressor Along With Test Certificate / Invoice Of Purchase From Authorized Dealer, Faulty Compressor Shall Be The Property Of Contractor. 27 S / F Of Following Item In Exsiting Mv Panel / Mcb Db / Free Cooling I / C Dismentling Of Faulty Unit ( If Reqd ) I / C , Connections, Testing Etc Comp As Reqd. 28 5 A To 32 A , 240 / 415 V, 10 Ka, C Curve, Sp Mcb 29 5 A To 32 A , 240 / 415 V, 10 Ka, C Curve, Tp Mcb 30 5 A Plug Top 31 15 A Plug Top 32 Supplying And Fixing Dp Sheet Steel Enclosure On Surface / Recess Along With 25 / 32Amps 240 Volts C Curve Dp Mcb Complete With Connections, Testing And Commissioning Etc. As Required. 33 Replacement Of Following Faulty Accessories In Exsiting Timer / Controllor Unit , Connections, Testing Etc Comp As Reqd. ( Make--Legrand Or Similar Superior Make ) 34 2 Pole Contactor 25 A , 230V ( Make-L&T- 25 A-Mnx ) 35 Supplying & Fixinganalogdaily Time Switch Of 16 A Capacity, One C / O, Din / Base Mounting , 24 Hour Programmable Operation For Used For Automatic Switching On / Off For Electric Street Lightssuitable To Work On 230 V Ac Supply I / C Connection Etctimer - ( Make-L&T / Gic Or Similar Superior Make ) 36 Installation, Testing & Commissioning Of The Followingtype Split Type Ac Unit At A Specified Location As Per Direction Of Engg-In-Charge By Mounting / Fitting Indoor And Outdoor Units , Making Opening In Wall Behind Indoor Unit , Laying And Fixing Of Both Liquid And Hot Gas Lines , Inter Connecting Wiring For Both Indoor Outdoor Units Up To 3 Mtrs Length And , Interconnecting The Indoor Unit And Outdoor Unit With Refrigerant Line, Insulating The Refrigerant Pipe With Expandable Polyethylene Foam Tubing Unit And Fixing Withsuitable Ms Shaddle , Leak Testing Entire System , Vacuemising The System , Charging Of Refrigerant Gas In The Unit , Making Power Supply Connections From The Power Point, And Making Good The Damages Etc.As Required. 37 1.5 / 2 Tr Split Ac Unit 38 2X1.5 / 2 Tr Hshf Ac Unit 39 Pdg And Fixing Of Following Size Additional Followingsize Same As Supplied By Split Ac Manufacturer Refrigerant Copper Piping With 3X2.5 Sq.Mm. Pvc Insulated Pvc Sheathed Copper Cable I / C Covering Of Copper Pipe With Polystyrene Insulation I / C Cutting , Brazing , Jointing, Bends, Sockets Etc As Reqd. ( Note- Combined Length Shall Be Measured ) 40 1 / 4&5 / 8 41 3 / 8&5 / 8 42 S / F Of 50 Mm Diapvc Pipe For Wall Crossingofrefrigerant And Drain Pipeofsplit Ac Units Etc Asreqd. 43 S / F Of 19 Mm Dia Pvcwire Bradedpipe For Drain Water Ofspaci / Cfixing On Wall Surface With Suitable Ms Shaddle Etc.Astereqd. 44 S / F Powder Coated Ms Stand, For Wall / Floormounting Of Outdoor Unit Ofsplit Ac I / C Fixin Gthe Same On Wall With Suitable Fastner Etc As Reqd 45 Supplying And Fixing Of Following Size Of White Colour Flexible Copper Cable On Surface / Recess, Suitable For Work On 230 Volt, 50 Hz Ac Supply I / C Connection Etc As Reqd ( Note--Cables Have Joints Shall Be Replaced To Avoid Fire Hazard ) 46 3X1.5 Sq Mm 47 3X2.5 Sq Mm 48 Insulating The Existing Laid Refrigerant Pipe With Expandable Polyethylene Foam Tubing Unit And Fixing Withsuitable Ms Shaddle Etc As Reqd 49 Dismantling Of The Existing Split / Windowtypeac Unit Complete With Indoor Unit, Outdoor Unitstand, Refrigerant Piping, Drain Pipe, Shifting The Dismaltled Items To A Safe Place In Exchange Premises And Handing Over To The Incharge, Packing Of Spac Wall Hole , Making Good The Damage Etc As Reqd . 50 Dismantling Of The Existing2x1.5 / 2 Tr Hshf Typesplitac Unit Complete With Indoor Unit, Outdoor Unitstand, Refrigerant Piping, Drain Pipe, Shifting The Dismaltled Items To Other Room In Same Exchange Premises , Packing Of Spac Wall Hole , Making Good The Damage Etc As Reqd . 51 Installation Of Existing 1.5 / 2 Trreciprocating / Rotary Type Comressor In The All Type Ac Units I / C Connecting With Existing Refrigerent Pipeline I / C Vacuemising , Nitrogen Pressure Testing , Etc As Reqd 52 Closing Of Existingwindow In Ac Openingarea To Prevent Ac Leakage / Theftby Single Brick Masnoary I / C Plastering With Cement Mortar , Finishing Etc Complete As Reqd As Reqd. 53 Transportation Ofsplit / Windowac Units / Water Coolerwith All Acessorieslike Indoor , Outdoor Unit , Copper Pipe , Drain Pipe , Partical Board , Standfromone Te Buildingto Variouste / Btssites In Ba Dehraduni / C. Loading, Unloading Etc. As Reqd. 54 Sitc Of 400 Mm Sweeposcillating Type Wall Mounted Fan With Three Speed Control Regulator Having 1350Rpm Speed , 70 M3 / Min Air Deliverysuitable Forworking On 230 V , 50 Hz Single Phase Ac Supply & I / C Fixing On Wall With Suitable Fastner , Connection Etc. Complete As Required ( Crompton / Bajaj / Orient / Polar / Almonard / Usha ) 55 Sitc Of 450 Mm Sweeposcillating Type Wall Mounted Fan With Three Speed Control Regulator Having Metalic Bodyand Metal Blade , 1325 Rpm Speed , 6030 M3 / Hour Air Displacement, Suitable Forworking On 230 V 50 Hz Single Phase Ac Supply & I / C Fixing On Wall With Suitable Fastner , Connection Etc. Complete As Required ( Crompton / Bajaj / Orient / Polar / Almonard / Usha ) ( Conference Hall ) 56 S / F Offollowingsizemetallic Bodyexhaust Fan With Front Guard , 1350 Rpm, Air Delivery 550 Cmh Suitable For Operation On 230 Volts , Single Phase50 Hz Ac Supply Complete Etc As Reqd ( Make - ( Bajaj / Polar / Usha / Crompton / Havells / Orient ) 57 300Mm 58 Supplying & Fixing Ofpowder Coated Free Cooling Unit Made Out Of 18 Gauge M.S.Sheetbox With Locking Door In Front & Jali In Back Side I / C Supplying & Fixing 300 Mm Sweep Heavy Duty Exhaust Fan 1400 Rpmsuitable For 230 V 50 Hz Ac Supply I / C Making Opening In Brick Wall / Window For Fixing Of Unit, Connection , Testing Etc ( Exhaust Fan Make-- Crompton / Havells / Bajaj Or Similar Superior Make ) 59 Out Door Unit ( For Exhaust Of Hotair ) 60 S / F Timer Unit Constituting Of 01 No. Digital Type Thermostat / Temp Controller With Led Display & Sensor With Lead And 01 No.Analog Time Switch / Electronic Timer ( 1 Second To 10 Hrs ) In Suitable Size Ms Box With Hinged Door, Connection Etc. As Required. ( Timer Make-Bch / L&T / Gic-J648b1& Analog Time Switch Make - Selec - Tc513 / Tc533bx Or Similar Superior Make ) Note--Timer Will Runexhaust Fan For 2 Hrs And Kept In Off Position For 15 Minutes

Key Value

Document Fees
INR 590 /-
EMD
INR 8873.0 /-
Tender Value
INR 4.43 Lakhs /-