Bharat Coking Coal Limited-BCCL has published Tender For Construction Of Transformer Room Near Br Company And Bararee 06 No. Pit Under Lodna Area.. Submission Date for this Tender is 11-04-2024. Building Work Tenders in Dhanbad Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

43053512
Tender For Construction Of Transformer Room Near Br Company And Bararee 06 No. Pit Under Lodna Area.
Open Tender
Indian
Jharkhand
Dhanbad
11-04-2024

Tender Details

Construction Of Transformer Room Near Br Company And Bararee 06 No. Pit Under Lodna Area.

Key Value

Document Fees
Refer document
EMD
INR 110600.0 /-
Tender Value
INR 88.46 Lakhs /-

BOQ Items

Name of Work: Construction of New Transformer Room Near BR Company and Bararee 6 no. pitUnder Lodna Area vide eNIT Ref.BCCL/LA/CIVIL/NIT/2023-24/171; dated: 27.03.2024
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressingofsidesandrammingofbottoms,liftupto1.5m,includinggettingoutthe excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
2Supplyingandfillinginplinthwith sandunderfloors,includingwatering,ramming, consolidating and dressing complete.
3Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources).
4Providing and laying in position specified grade of reinforced cement concrete, excluding thecost of centering, shuttering, ifnishing and reinforcement- All work up to plinth level : 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
5Reinforcedcement concreteworkinwalls(any thickness), includingattached pilasters, buttresses,plinthandstring courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3(1cement:1.5coarsesand(zone-III)derivedfrom naturalsources:3graded stone aggregate 20 mm nominalsize derived from natural sources).
6Reinforcedcementconcreteworkinbeams,suspended floors,roofshaving slopeup to 15°landings,balconies, shelves, chajjas, lintels, bands, plain window sills, staircases andspiralstaircasesaboveplinthleveluptofloorfivelevel,excludingthecostof centering,shuttering,finishingandreinforcement, with1:1.5:3(1 cement:1.5 coarse sand (zone-III)derivedfromnaturalsources: 3gradedstone aggregate 20mm nominal size derivedfrom natural sources).
7Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
8Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
9Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
10Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
11B/work (1:6) f/p
12B/work (1:6) s/st
13Providingand laying damp-proof course 40mm thickwithcement concrete1:2:4 (1cement : 2 coarse sandderived fromnatural sources): 4 graded stone aggregate12.5mm nominal size derived from natural sources)
14Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
15Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
16Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
17Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover
18Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.
19Brick flat soling
20Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4(1cement: 2coarsesand(zone-III)derivedfrom natural sources: 4gradedstone aggregate 20 mm nominal size derived from natural sources).
2112 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
22White washing with lime to give an even shade : New work (three or more coats)
23Colour washing such as green, blue or buff to give an even shade :New work (two or more coats) with a base coat of white washing with lime
24Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
2512 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand)
26Extra for providing and fixing wind ties of 40x 6 mm flat iron section.
27Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. Group A
28Supplying and fixing brass batten / angle holder including connection etc. as required
29Supplying and fixing 3 pin, 5 amp ceiling rose on the existingjunction box/ wooden block including connection etc as required
30Supplying and fixing following piano type switch/ socket on theexisting switch box/ cover including connections etc. as required. 3 pin 5/6 amp socket outlet
31Supplying and fixing following piano type switch/ socket on theexisting switch box/ cover including connections etc. as required. 15/16 amp switch
32Supplying and fixing following piano type switch/ socket on theexisting switch box/ cover including connections etc. as required. 6 pin 15/16 amp socket outlet
33Providing and fixing following capacity TP&N disconnector fuseswitch unit inside the existing panel board with ISI marked HRCfuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP&N
34Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
35Total impact of GST for the purpose of CTC
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail