|
| 1 | WTP Consumables(Yearly)Chlorine |
| 2 | Manpower(Yearly) |
| 3 | Project I/C (Facility Management) |
| 4 | Supervisor (skilled) |
| 5 | Operator (WTP) |
| 6 | Plumber |
| 7 | Helper for WTP |
| 8 | Electrical Maintenance service including Manpower - Electricians (Skilled) |
| 9 | Electrical Maintenance service including Manpower - Electricians Helper (Un-Skilled) |
| 10 | Unskilled(Housekeeping & Sweeper) |
| 11 | Manpower (Mason,Carpenter) as & when required |
| 12 | Township Security Services (private Security service) |
| 13 | Trash/Waste Removal including collection & Transportation |
| 14 | Housekeeping / Cleaning Services consumables |
| 15 | RegularMaintenance of Existing Horticulture & Landscaping Area |
| 16 | Regular maintenance of lawn having different type of grass (Mexican grass/ Selection-1 grass) (As per scope of Work) |
| 17 | Regular maintenance of rose & sesonal flower bed at selective location (All Season) as per scope of work. |
| 18 | Seasonal flower bed (Area equivalent to circular Size of 16ft in dia) |
| 19 | Rose flower bed (Area equivalent to circular Size of 20ft in dia) |
| 20 | Development & Maintenance |
| 21 | Supply and planting trees, bushes, hedges etc. of desired height and size.(as per scope of work) |
| 22 | Cycas/ficus plants |
| 23 | Royal Palm of 6 feet height |
| 24 | Rongon tree |
| 25 | Bougainvillea Tree |
| 26 | Gulmohar tree |
| 27 | Thuja |
| 28 | Supplying and planting paved quality hedge plants (As per scope of work) |
| 29 | Township maintenance work (Civil) |
| 30 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. |
| 31 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:1:2:4 ( 1 Cement: 2 fine sand : 4 graded stone |
| 32 | Centering shuttering including struttings, propping etc. and removal of form work for:Retaining walls, return walls, walls (any thickness) including attached pilasters, but-tresses plinth and string courses fillets etc. |
| 33 | Extra for concrete work in superstructure above floor V level for each four floors or part thereof. |
| 34 | \"Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement--All work upto plinth level:\"1:2:4 ( 1 Cement: 2 fine sand : 4 graded stone aggregate 20 mm nominal size) |
| 35 | Centering shuttering including struttings, propping etc.and removal of form work for:Foundations, footings, bases for columns etc. for mass concrete with timber plank |
| 36 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or |
| 37 | First class brick work in foundation and plinth including cost of all materials as required complete:-In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 38 | Half brick masonry work with first class bricks in foundation and plinth including cost of all materials asrequired complete:-In cement mortar 1:3 ( 1 cement : 3 fine sand ). |
| 39 | Extra for half brick masonry work in superstructure above floor-V level for each four floors or part thereof by mechanical means by lifting material using mobilecrane as required complete. |
| 40 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete.Fixed to openings /wooden frames with rawl plugs screws etc. |
| 41 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : 300x10 mm |
| 42 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 125 mm |
| 43 | Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessaryscrews etc. complete. |
| 44 | Providing & Fixing factory made 30 mm thick PVC Door Shutter (Single Sheet) with Frame as per Manufacturer (SINTEX, D-90) with all accessories at all floor levels in all complete. |
| 45 | Providing structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete as required. |
| 46 | \"Providing and fixing 1st class quality ceramic glazed wall tiles conforming to IS : 15622 - 2017 (thickness to be specified by the manufacturer) of approved make in all colours, shades of any size as approved by Engineer-incharge in skirting, risers of steps and dados, laid over 12 mm thick bed of cement mortar 1 : 3 (1 cement : 3 fine sand) jointed with ordinary cement slurry including pointing with white cement mixed with pigment of matching shade etc. all complete as per direction of the Engineer in-charge.\"450 mm X 300 mm in all shades and design |
| 47 | \"Providing and laying 1st class quality vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 - 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. all complete as per direction of the Engineer-in-charge..\" Soluble Salt Stainfree vitrified tiles (Glossy)Size of tile 600 mm x 600 mm |
| 48 | 12 mm cement plaster of mix Cement mortar 1:3 (1 cement : 3 fine sand) |
| 49 | 6 mm cement plaster of mix : Cement mortar 1:3 (1 cement : 3 fine sand) |
| 50 | Extra for plastering exterior walls of height more than 10 m from GL for every additional height of 3 m or part thereof complete. |
| 51 | Distempering with 1st quality washable acrylicdistemper of approved brand and manufacture and ofrequired shade on old work ( one or more coats ), togive an even shade as required complete as perdirection of the Engineer in charge. |
| 52 | Painting with synthetic enamel paint ( one or more coats ) of required colour of approved brand and manufacture on old work to give an even shade including preparation of surface as required complete as per direction of the Engineer in charge. |
| 53 | Demolishing reinforced cement concrete manually / by mechanical means including stacking of steel bars properly and disposal of unserviceable material with all lifts and upto 50 m lead etc. complete as per direction of the Engineer- in-charge. |
| 54 | Extra for cutting reinforcement in RCC or R.B. work manually / by mechanical means (payment to made on the cross sectional area of RCC or R.B. work) etc. complete as per direction of the Engineer- in-charge. |
| 55 | Demolishing brick work including stacking of serviceable materials and disposal of unserviceable materials with all lifts and upto a lead of 50m etc. complete as per direction of the Engineer- in-charge:-In cement mortar. |
| 56 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up of gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawing and the direction of Engineerincharge. (Glazing and paneling and dash fasteners to be paid for separately) :- For fixed portion of approved quality:- Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15). |
| 57 | For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately ):- Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15). |
| 58 | Providing and fixing glazing of approved quality in aluminium doors, windows, ventilator, shutters and partition etc. with EPDM rubber / neoprene gasket etc. complete as per architectural drawing and the direction of Engineer-in-charge (Cost of snap beading shall be paid in basic item) :- With float glass panes of 5.5 mm thickness ( weight not less than 13.75 kg / sqm ) Sqm. |
| 59 | Filling the gap in between aluminium frame and adjacent RCC/brick work by providing weather silicon sealant over backer rod of approved quality etc. complete as per architectural drawing and direction of the Engineer-in charge:- (i) Upto 5 mm depth and 5 mm width. |
| 60 | Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work 50 mm diameter pipe |