Tender For Special Repair To Bldg No. P-668, Bldg No. T-528A ( Lpg Shed ) , Bldg No. T-13 ( Dal Shed ) And Bldg No. T-18 ( R / Oil Shed ) At 436 Coy Asc ( Sup ) Type ‘A’ Under Ge Bhopal, bhopal-Madhya Pradesh

Military Engineer Services-MES has published Tender For Special Repair To Bldg No. P-668, Bldg No. T-528A ( Lpg Shed ) , Bldg No. T-13 ( Dal Shed ) And Bldg No. T-18 ( R / Oil Shed ) At 436 Coy Asc ( Sup ) Type ‘A’ Under Ge Bhopal. Submission Date for this Tender is 16-04-2024. Building Work Tenders in bhopal Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43019886
Corrigendum : Tender For Special Repair To Bldg No. P-668, Bldg No. T-528A ( Lpg Shed ) , Bldg No. T-13 ( Dal Shed ) And Bldg No. T-18 ( R / Oil Shed ) At 436 Coy Asc ( Sup ) Type ‘A’ Under Ge Bhopal
Open Tender
Indian
Madhya Pradesh
bhopal
16-04-2024

Tender Details

Special Repair To Bldg No. P-668, Bldg No. T-528A ( Lpg Shed ) , Bldg No. T-13 ( Dal Shed ) And Bldg No. T-18 ( R / Oil Shed ) At 436 Coy Asc ( Sup ) Type ‘A’ Under Ge Bhopal

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 16-04-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 89600.0 /-
Tender Value
INR 44.80 Lakhs /-

BOQ Items

Name of Work : SPECIAL REPAIR TO BLDG NO. P-668, BLDG NO. T-528A (LPG SHED), BLDG NO. T-13 (DAL SHED) AND BLDG NO. T-18 (R/OIL SHED) AT 436 COY ASC (SUP) TYPE ‘A’ UNDER GE BHOPAL
Sl. No. Item Description
1Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
2Dismantling of asbestos cement (corrugated, semi corrugated etc.) sheets inroof coverings including ridge complete all as specified and directed.
3Dismantling wooden fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and directed.
4M&L for mild steel work of tubular shapes (round/square/rectangular) of pipes as approved,trusses of semi circle shape including post, special shaped washers etc complete including necessary nuts, bolts, wind ties and gusset plates etc using ERW or induction butt welded tubes conformining to IS 1161-1998 grade St-240 complete all as specified and directed.
5M&L for mild steel work of angle iron, flat iron, plates as in brackets, cleats, fastners, wind ties, supports, base for posts etc with riveted, bolted or welded attachment of Fe-410-W (Gde-E-250) quality-A complete all as specified and directed.
6M&L for preparation of new or untreated steel & iron surfaces of any description over 10cm in width or girth and applying two coat of synthetic enamel paint over a coat of zinc oxide primer complete all as specified and directed.
7M&L for preparation of new wood or wood based surfacea of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed.
8S&F of pre-painted galvalume aluminum zinc coating GI based corrugated steel sheeting 0.50mm thick (AZ-150) of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, chajjas, etc; and fixed with self tapping screws complete all as specified and directed.
9S&F of pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick (AZ-150) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall and other similar works and fixed with self tapping screws complete all as specified and directed.
10Taking down chowkhats or frame n. exc 1.5 sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed.
11Taking down chowkhats or frame exc 1.5 sqm but n exc 4.00 sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed.
12S&F of powder coated aluminium fabricated work (minimum thickness of powder coating 50 micron) as in doors, windows, partition, ventillator etc complete with and including necessary jointing cleats, anodised aluminium snap beading complete all as specified and directed.
13S&F of 5.5 mm thick selected quality glass (black tinted) of any approved shade and glazing to existing aluminium frame work complete all as specified and directed.
14S&F in repairs stainlesssteel wire cloth 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed and with tinned tacks complete all as specified and directed.
15M&L for factory made 35 mm thick flush door shutters, solid core construction with block board core and plywood face panels, commercial type on both sides and both face is covered with decorative face veneer with 0.9 to 1 mm thick lipping/frame to match and fixed to chowkhats complete all as specified and directed (Make: Jain wood Industries/ M/s Goel Brothers/ M/s Goyal Industries/ M/s Pioneer Timber Chandigarh as approved by GE)
16S&F of factory made 30 mm thick, IInd class hard wood glazed and skelton shutters more than 2 panel, open rebated and prepared to receive glass, gauze, etc. (with out sash bars), edges of framing plain, chamfered or roundeed, fitted with cut and mitred beads for securing glass, etc; sizes of members of shutters as specified in SSR part I, section 8, clause 8.24 (a) and fixed to chowkats complete all as specified and directed. (Make: Jain wood Industries/ M/s Goel Brothers/ M/s Goyal Industries/ M/s Pioneer Timber Chandigarh as approved by GE)
17Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed.
18M&L for granite stone work of 18-20 mm thick(of any type) (table rubbed) and polishshed as in cooking platform, steps, jambs, pillar and like including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite over and including 15 mm thick screed bed in cement mortar 1:4 complete all as specified and directed
19M&L for machine cut kota stone slab flooring 20-22mm thick, laid over and including 20mm thick screed bed in cement mortar 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete all as specified and directed.
20M&L for machine cut kota stone slab of 20-22mm thick as in skirting, risers etc; over and including 10 mm thick rendering in cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete all as specified and directed.
21S&F of 125 x 60 mm pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete made out of 1.25mm thick mild steel sheet complete all as specified and directed.
22M&L for mild steel framed work such as grills, gratings, gate, doorsetc with ends of barssouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, frame for partition, framed balusters, walkways, railing, frame work of water tanks and similar work conforming to Fe-290, Gde E-165 complete all as specified and directed.
23Demolition of cement concrete in ground floor, (unreinforced) paving n exc 15 cm thick (below or above GL) complete all as specified and directed
24M&L for hardcore of broken stone or boulders of guage n exc 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface complete all as specified and directed.
25M&L for 75 mm thick PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in plinth protection, aprons, hard standing, path and like including finishing the surfaces even and smooth without using extra cement complete all as specified and directed
26M&L for cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as infoundation, filling, subbase and mass concrete complete all as specified and directed.
27S&F of steel rolling shutters with thickness of lath 1.25 mm, gear operated type with bevel gear box and crank handle with and including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete; push pull complete all specified and directed.
28M&L for providing PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in copings/benching and similar works complete all as specified and directed.
29Demolition of brick work, built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
30M&L for brick work with fly ash bricks (modular size bricks), straight or curved on plan exc 6 m mean radius, built in CM 1:6 complete all as specified and directed.
31M&L for brick work with fly ash bricks (modular size bricks), straight or curved on plan anyradius in half brick thick walls, built in CM 1:4 complete all as specified and directed.
32Taking down cement plaster on brick or concrete surfaces and wall tiling if any includingracking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
33M&L for 15mm thick rendering in CM 1:6 on new or old brick/concrete surfaces including finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
34M&L for 15mm thick rendering in CM 1:4 on new or old brick/concrete surfaces including finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
35M&L for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including a coat of 1 mm thick waterproof putty and priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces of walls complete all as specified and directed.
36M&L for complete removal of existing treatment of walls and applying two coats of oil bound distemper over a coat of wall primer complete all as specified and as directed.
37M&Lfor applying 2-3 mm thick waterproof white wall putty on walls, finished even and smooth complete all as specified and directed.
38M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hookings ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
39S&F of 200 mm long aluminium anodised barrel tower bolts, extruded section and fixed complete all as specified and directed.
40S&F of 250mm long aluminium alloy anodised sliding door bolts with hasp & stapple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
41S&F of 100 mm mild steel butt hinges, medium weight, cold rolled and fixed complete all as specified and directed.
42S&F of 150 mm long aluminium handles, cast type, anodised and fixed complete all as specified and directed.
43S&F in repairs galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperure 1.18 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
44S&F in repairs 20mm dia curtain rails of stainless steel with chromium plated ornamental brackets, stops rollers etc; and fixed complete all as specified and directed.
45M&L for non skid ceramic coloured tiles 7 to 8mm thick (square /rectangular) area of each tile exceeding 0.11 sqm but not exceeing 0.18 sqm as in floors over and including 15mm thick screed in CM 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of tiles complete all as specified and directed.
46M&L for 100 mm thick PCC, 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub bases, sub floors foundation, etc cmplete all as specified and directed.
47M&L for 100 mm thick PCC 1:2:4 type B-2 (using 40 mm graded aggregate) as in sub base, floors and paving complete all as specified and directed.
48M&L for providing industrial mastic flooring in bitumen godown/ LPG store by laying 25mm thick mastic asphalt wearing course with paving grade bitumen meeting the requirements given in table 500-39, prepared by using mastic cooker and laid to required level and slope after cleaning the surface including providing antiskid surface with bitumen precoated fine-grained hard stone chipping of 13.2mm nominal size at the rate of 0.005 cum per 10 sqm and at an approximate spacing of 10 cm centre to centre in both directions, pressed into surface when the temperature of surfaces not less than 1000C, protruding 1mm to 4mm over mastic surface complete as per latest specification complete all as specified and directed.
49M&L for machine pressed precast concrete interlocking paver block (Reflective type) in any shape and size confirming to IS-15658-2006 of 80 mm thickness M-40 grade with grey cement and pigment complete all as specified and directed.
50M&L for clean dry sand filling under paver block and similar work including watering and consolidation complete all as specified and directed.
51M&L for cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in coping, benching etc; for drain and similar works complete all as specified and directed.
52Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
53M&L for concealed point wiring with 1.50 sqmm (nominal area), FRLS PVC insulated, unsheathed, single core multi-stranded copper conductor cable, 1100 volts grade, drawn through and including concealed medium grade PVC conduit not less than 20 mm dia, ISI marked, with all accessories (PVC casing and caping of size 25 mm, ISI marked with complete accessories to be used wherever wiring to be run on ceilings and concrete surfaces) including one run of 1.5 sqmm FRLS multi stranded copper conductor (Green colour cable) as earth continuity wire connected to common earth dolly including modular galvanized sunk sheet steel terminal box concealed in wall for fixing of switches, sockets and fan regulators etc, complete all as specified and directed for the followings:-
54(a) One light /Fan/Exhaust point controlled by one switch.
55(b) One 3 pin socket outlet on same board.
56All as per item No. 52 here-in-before but wiring with 2.5 Sq mm FRLS multi-stranded copper conductor cable for 5/15 amp switch socket on independent board and with 2 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete.
57M&L for concealed point wiring for one light /fan/exhaust point controlled by one switch with 1.50 sqmm (nominal area), FRLS PVC insulated, unsheathed, single core multi-stranded copper conductor cable, 1100 volts grade, drawn through and including concealed medium grade steel conduit not less than 20 mm dia, ISI marked, with all accessories including one run of 1.5 sqmm FRLS multi stranded copper conductor (Green colour cable) as earth continuity wire connected to common earth dolly including modular galvanized sunk sheet steel terminal box concealed in wall for fixing of switches, sockets and fan regulators etc, complete all as specified and directed.
58All as per item No. 54 here-in-before but wiring with 2.5 Sq mm FRLS multi-stranded copper conductor cable for 5/15 amp switch socket on independent board and with 2 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete.
59S&F of modular switch 1 way, 5 A, 1 module, 240 Volts and fixed complete all as specified and directed.
60S&F of modular socket, 6 A, 2/3 pin, combined 2 module, 240 Volts and fixed complete all as specified and directed.
61S&F of modular socket 6A/16A, 2/3 pin combined, 2 module, 240 Volts and fixed complete all as specified and directed.
62S&F of modular switch, 1 way, 16 A, 1 module, 240 Volts and fixed complete all as specified and directed.
63S&F of modular white cover plate with frame, 2 Module and fixed complete all as specified and directed.
64S&F of modular white cover plate with frame, 4 Module and fixed complete all as specified and directed.
65S&F of modular white cover plate with frame, 6 Module and fixed complete all as specified and directed.
66S&F of modular white cover plate with frame, 8 Module and fixed complete all as specified and directed.
67S&F of ceiling rose surface bakelite 65mm dia three terminal complete all as specified and directed .
68S&F of flame proof switch socket & plug combination in LM6 cable termination box in LM6, 16A, 250 Volt, 2P+earth complete all as specfied and directed.
69S&F of flame proof switch rotary type with termination box in LM6, 16A, single pole, 250 Volt complete all as specfied and directed.
70S&F in replacement light fitting 2x16 Watt flameproof, CMRI certified recommended for gas/ vapour group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures, driver,holders, connector etc. Complete with all accessories prewired and including connecting up with 1 sqmm three core flexible copper conductor cable with suitable size complete all as specified and directed.
71S&F in replacement LED tube light fitting 1 x 20 Watt, 220 V, AC decorative box type with driver, holderincluding making connection with 1 Sqmm flexible copper conductor cable 3 core ofsuitable size from ceiling rose complete all as specified and directed.
72M&L for replacement of sub main wiring with two single core 6 Sqmm multi stranded copper conductor, FRLS, PVC insulated, unsheathed cable with and including rigid non metallic PVC conduit medium grade, ISI marked, 25 mm dia for sub main wiring and 6.0 sqmm FRLS, PVC insulated and unsheathed stranded copper conductor cable as earth wire in surface/recess and making good to the disturbed surfaces to match the existing surfaces including taking down existing unserviceable sub main of any type and size complete all as specified and directed. Note:- Three runs of 6.0 Sq mm copper conductor cable and one run of PVC conduit will be measured as one unit.
73M&L for replacement of sub main wiring with two single core 6 Sqmm multi stranded copper conductor, FRLS, PVC insulated, unsheathed cable with and including steel conduit medium grade, ISI marked, 25 mm dia for sub main wiring and 6.0 sqmm FRLS, PVC insulated and unsheathed stranded copper conductor cable as earth wire in surface/recess and making good to the disturbed surfaces to match the existing surfaces including taking down existing unserviceable sub main of any type and size complete all as specified and directed. Note:- Three runs of 6.0 Sq mm copper conductor cable and one run of PVC conduit will be measured as one unit.
74S&F in replacement sheet metal enclosure for MCB, 240 Volts, 200 Amps rated busbar, 8 way double door, factory made conforming to IS:13032 fabricated out of CRCA sheet not less than 1.2mm thick fitted with DIN channel, neutral link complete all as specified anddirected.
75S&F of RCBOs for earth leakage, over load & short circuit protection, double pole, 30 mA, 16 Amps and making necessary connection complete all as specified and directed.
76S&F of MCB single pole, 6 to 32 Amps, 240 Volts, 10 KA breaking capacity,"B" Curve and making connections complete all as specified and directed.
77M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly in ground vertically at a depth not less than 2.25 m and top edge of plate at a depth not less than 1.50 m below GL, connected to earthing lead of galvanized steel wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised steel from earth plate to test oint upto 7.5m including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 15 mm dia GI pipe medium grade for watering, 15 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing compelete all as specified and directed.
78S&F in replacement integral LED street light luminaire, 60 Watts, comprising of pressure die cast housing with epoxy powder coated dark graphite grey colour finish, prismatic polycarbonate cover with individual LED lenses with IP 65 protection and all fixing arangement, nuts, bolts and washer and making connection with 2.5 sqmm, 2 core PVC copper conductor cable of required length from light fitting to street light control box on pole complete all as specified and directed.
79S&F in replacement integral LED street light luminaire, 24 Watts, comprising of pressure die cast housing with epoxy powder coated dark graphite grey colour finish, prismatic polycarbonate cover with individual LED lenses with IP 65 protection and all fixing arangement, nuts, bolts and washer and making connection with 2.5 sqmm, 2 core PVC copper conductor cable of required length from light fitting to street light control box on pole complete all as specified and directed.
80Excavation in trenches in hard/dense soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out for foundation, laying under ground cables, erection of poles etc complete all as specified and directed.
81Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed.
82Removing of surplus excavated materials to a distance not exc. 50 Mtr away and depositing where directed at a level not exc. 1.50 mtr above the starting point complete all as specified and directed.
83M&L for dry sand cushioning in trenches for protection of UG cables (below, above and around the cable) and consolidated (punned) complete all as specified and directed. Note: Punned thickeness of sand will be measured for payment purpose.
84M&L for brick with sub class "B" bricks, locally available of best quality and laid in trenches above sand cushioning for cable protection complete all as specified and directed.
85S&F in replacement of XLPE cable 1100 Volts grade, heavy duty of cross-sectional area 16 Sqmm, 2 core with aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel strip and overall PVC sheathed, laid in trenches/floor or fixed on wall/pole and connecting complete all as specified and directed.
86S&F in replacement GI tubes, "light grade" galvanised with all fittings, laid in floors, under road, pavement or hard standing of 50 mm bore for protection of cables complete all as specified and directed.
87M&L for cutting of PCC/floor/road and taking out cable and making good with PCC 1:2:4, type B-1 (using 20 mm graded stone aggregate as per existing after laying of pipe for cable size of trench not more than 0.30 x 0.30 m complete all as specified and directed.
88Schedule of credit (calculation will be done off line) Rs. 42061.00