Bharat Sanchar Nigam Limited-BSNL has published Tender For Attending Mv/Lt Electrical Faults And Repairing Of Ei N Fans And Service Connection Cables Etc. For Various Tes/Bts In Berhampur Ba Zone-Ii Exchanges And Bts Sites Under Boudh And Kandhamal Revenue Districts.. Submission Date for this Tender is 01-04-2024. Electrical Products Tenders in berhampur Odisha. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | AttendingElectrical Faults of LT/MV electrical system comprising ofLT/MV Service connection line, Feeder panel, Main Distribution panel, MCB DBs, Riser mains etc. on need basisby deputing qualified and trained/skilled technician havingvalid Electrical License of appropriate voltage and making arrangements forchecking, testing with suitable testing devices, fault finding, replacing faulty MCBs/Isolators/Switches/lamps/holders etc. bynew ones (cost of materials are not included in the scope of this item and will be paid separately) andrestoration of the Power supply to the Telephone Exchange/Admin Bldg/BTS/Staff Quarters complex within reasonable time periodetc. complete as required. |
2 | Distance up to 25 Kms from Berhampur |
3 | Distance above 25 Kmsand up to 100 Kms from Berhampur |
4 | Distance above 100 Kmsand up to 200 Kms from Berhampur |
5 | Replacement of the faulty and burn out MCBs, Isolators etc. by new ones of following ratings MCBs and Isolators ISI marked as per IEC 60947-3 /MCBs 10 kA , C- Curve as per IEC 60947-2 in existing MCBDBs i/c connection testing etc. as required.(Make-Legrand / L&T / Schneider Electric / Siemens/Havells ) |
6 | 100Amps 4 pole Isolator |
7 | 63Amps 4 pole Isolator |
8 | 63Amps 4 pole MCB |
9 | 63 AmpsDP MCB |
10 | 32Amps 3 pole MCB |
11 | 40Amps DP Isolator |
12 | 40Amps DP MCB |
13 | 6-32A SPMCB |
14 | Replacement of the faulty and burn out Fuse links by new ones of following ratingsi/c connection testing etc. as required.(Make-Legrand / L&T / Schneider Electric / Siemens/Havells ) |
15 | 32 Amps 415VHRC Fuse links- Cylindrical type(L&T/Havells) |
16 | 63 Amps 415VHRC Fuse links- Cylindrical type(L&T/Havells) |
17 | 32 Amps 415VHRC Fuse links-Boltedtype(L&T/Havells) |
18 | 63 Amps 415VHRC Fuse links- Bolted type(L&T/Havells) |
19 | 100 Amps 415VHRC Fuse links- DIN type(L&T/Havells) |
20 | 125 Amps 415VHRC Fuse links- DIN type(L&T/Havells) |
21 | 62 Amps 415VPorcelain Fuse unit |
22 | 100 Amps 415VPorcelain Fuse unit |
23 | Replacement of the following burnt out/damaged cable/wires/lugs/sockets etc. by new one of following types, sizes and ratings PVC insulated FRLS copper conductor single core stranded flexible cable i/c laying / drawing in existing conduit/pipe, connection, testing etc. as required. |
24 | 25sqmm with copper socketing |
25 | 16sqmm with copper socketing |
26 | 10sqmm with coppersocketing |
27 | 6sqmm |
28 | 4sqmm |
29 | 1.5sqmm |
30 | Replacement of the burnt out cables/wirings by the following sizes PVC insulated & PVC sheathed copper conductor multicore cable i/c fixing/laying on wall/ceiling with C clamps etc. as required. |
31 | 3 coreX2.5sqmm |
32 | 4 coreX2.5sqmm |
33 | 3 coreX4.0 sqmm |
34 | Supply of the following sizesPVC insulated & PVC sheathed Aluminium conductor armoured cable 650/1100 V. grade confirming to IS : 7098 (Part-1) 1988i/c transportation to respective sites etc. as required for replacement of faulty/burnt out cables. |
35 | 2 core 6 sqmm |
36 | 4 core 10 sqmm |
37 | 4 core 16 sqmm |
38 | 4 core 25 sqmm |
39 | 3.5 core 50sqmm |
40 | Replacement of faulty service connection cables by new one of 2 core X4sqmm PVC insulated and PVC sheathed Aluminium conductor weather proof cableetc. as required. |
41 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
42 | Up to 35sqmm |
43 | Above 35 sq. mm and up to 95 sq. mm |
44 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
45 | Up to 35sqmm |
46 | Above 35 sq. mm and up to 95 sq. mm (clamped with 25x3mm MS flat clamp) |
47 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size Up to 35sqmm direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
48 | Up to 35sqmm |
49 | Above 35 sq. mm and up to 95 sq. mm |
50 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size Up to 35sqmmin the existing Duct/Air as required. |
51 | Up to 35sqmm |
52 | Above 35 sq. mm and up to 95 sq. mm (clamped with 25x3mm MS flat clamp) |
53 | Replacement of damaged MV cable end terminationswith brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
54 | 4 X 16 sq. mm (28mm) |
55 | 4 X 25 sq. mm (28mm) |
56 | 3½ X 50 sq. mm (35mm) |
57 | Replacement offaulty SDFU switchesby new ones of following ratings after dismantlingthe old defective ones, fixing, connection & testing etc. as required. |
58 | 32 Amps 415 volts TPN SDFU withHRC fuses (open execution type). (Make: L&T FN type, /Havells / Siemens) . |
59 | 63 Amps 415 volts TPN SDFU with HRC fuses (open execution type).(Make: L&T FN type, /Havells / Siemens) . |
60 | 100 Amps 415 volts TPN SDFU with DIN type HRC fuses (open execution type). (Make: L&T FN type, /Havells / Siemens) . |
61 | 125 Amps 415 volts TPN SDFU with DIN type HRC fuses (open execution type). (Make: L&T FN type, /Havells / Siemens) . |
62 | Replacement offaulty SDFU switchesby new ones of following ratings with specious sheet steel enclosure so that there will be no need of separate cable gland boxes, having terminal shrouds and phase barriers on both sides suitable for Cylindrical/DIN type HRC fuse links, confirming to IEC-60947-3, IS/IEC:60947-3,after dismantlingthe old defective ones, fixing, connection & testing etc. as required. |
63 | 63 Amps 415 volts TPN SDFU in Sheet steel enclosure with DIN type HRC fuses.(Make: L&T FN type, /Havells / Siemens) . |
64 | 100 Amps 415 volts TPN SDFU in Sheet steel enclosure with DIN type HRC fuses. (Make: L&T FN type, /Havells / Siemens) . |
65 | 125 Amps 415 volts TPN SDFU in Sheet steel enclosure with DIN type HRC fuses. (Make: L&T FN type, /Havells / Siemens) . |
66 | Replacement offaulty Change over switchesby new ones of following ratings after dismantlingthe old defective ones, fixing, connection & testing etc. as required. |
67 | 63Amp 4-pole on load change over switch open execution type (Make: HPL Socomec /Havells / L & T) . |
68 | 125Amp 4-pole on load change over switch open execution type (Make: HPL Socomec /Havells / L & T) . |
69 | 63Amp 4-pole on load change over switch in sheet steel enclosure , front handle type (Make: HPL Socomec /Havells / L & T) . |
70 | 100Amp 4-pole on load change over switch in sheet steel enclosure , front handle type (Make: HPL Socomec /Havells / L & T) . |
71 | 125Amp 4-pole on load change over switch in sheet steel enclosure , front handle type (Make: HPL Socomec /Havells / L & T) . |
72 | Replacement offaulty MCCBs by new ones of following ratings Conforming to IS/IEC 60947-2 & IEC 60947-2 after dismantlingthe old defective ones, fixing, connection & testing etc. as required. |
73 | 63Amps 25 KA 3 pole 415 volts 50 Hz, with Magnetic Thermal over load release (L&T DN0-100C/Equivalent of Siemens/ABB/Havells) |
74 | 63Amps 25 KA 4 pole 415 volts 50 Hz, with Magnetic Thermal over load release (L&T DN0-100C/Equivalent of Siemens/ABB/Havells) |
75 | 100Amps 25 KA 3pole 415 volts 50 Hz, with Magnetic Thermal over load release (L&T DN0-100C/Equivalent of Siemens/ABB/Havells) |
76 | 100Amps 25 KA 4pole 415 volts 50 Hz, with Magnetic Thermal over load release (L&T DN0-100C/Equivalent of Siemens/ABB/Havells) |
77 | Replacement of faulty and damaged FTL fittings by new one of following ratings,LED Batten withpolycarbonate/Aluminium body suitable for operation on 140 volts to 270 volts AC, 50Hz i/c fixing and connection etc. as required. (Havells/Phillips / Surya / Polycab / Crompton) |
78 | 22 watt65000KDecorative ultra slim polycarbonate LED lighting fixture with high lumen output, environmental friendly, energy efficient ready to use pack. |
79 | 25 watt65000KDecorative ultra slim polycarbonate LED lighting fixture with high lumen output, environmental friendly, energy efficient ready to use pack. |
80 | 32 watt65000KDecorative ultra slim aluminium LED lighting fixture with high lumen output, environmental friendly, energy efficient ready to use pack. |
81 | 18 watt 6500KLEDpanel round/square Surface mounted Downlighter with ABS housing & PC Opal diffuser with integral electronic LED driver.. |
82 | 24 watt 6500KLEDsquare sleek surface mounted pressure die-cast aluminium luminaire in powder coated white finish in square profile with optimized heat sink for efficient heat dissipation and independent electronic LED driver. |
83 | 22W General purpose industrial compact batten suitable for singleLED Tube light with integral LED driver with single / double side connection options. (Make-Havells/Phillips/Bajaj/Wipro/Crompton) |
84 | 22W General purpose industrial compact batten suitable for Double LED Tube light with integral LED driver with single / double side connection options. (Make-Havells/Phillips/Bajaj/Wipro/Crompton) |
85 | Supply of the following electrical accessories/components for Electrical Light Fittings i/c testing etc. as required. |
86 | 36 /40 watt FluorescentTube rods |
87 | 36/40 watt Electronic ballast for Fl. Tube fittings |
88 | Starter for Fl. Fittings |
89 | Driver with universal connector for LED light fittings (15watt/18watt) |
90 | Driver with universal connector for LED light fittings (24watt) |
91 | 9 /10 wattLED Lamp (B22) |
92 | 14/15 wattBC LED Lamp (B22/E27) |
93 | 30 watt (B22/E27) LED lamp |
94 | 20/22W Ultra bright LED Tube light with very high efficacy >=115 lm/W & THD<10% suitable for installation in existing tube light G13 lamp holders to give glare free light. |
95 | Replacement of the lamp holders/ceiling roses etc. by new ones of reputed makes etc. as required. |
96 | Angle/batten Holder |
97 | 36/40 W Fl Tube light holder |
98 | 36/40 W Fl Tube light starter holder |
99 | Ceiling Rose |
100 | 5/6Amps 250 Volts 3 pin Plug top |
101 | 15/16Amps 250 Volts 3 pin Plug top |
102 | Replacement of the defective switches/sockets/lamp holders/ call Bells etc. by the new one of following ratings etc. as required. (Make- Anchor/Havells/Cona/ISI) |
103 | 6 /10 Amps 1 way modular type switch |
104 | 16/20 Amps 1 way modular type switch |
105 | 6 /10 Amps 1 way piano type switch |
106 | 20 Amps 1 way piano type switch |
107 | 6 /10 Amps 3pin modular type socket |
108 | 16/5 Amps 6 pin modular type socket |
109 | 6Amps 3 pin piano type socket |
110 | 16 Amps 3 pin piano type socket |
111 | Carry out repairing of Electrical Light Fittings by arrangingqualified and trained man power and tools, tackles, ladders etc. i/c dismantling of defective/faulty components and fixing of new components i.e chokes, lamps, starters, interconnection wires, lamp holders etc. as required. |
112 | Rewinding of 1200mm/1400mm ceiling fan by superior quality super enameled copper conductor i/c heat varnishing, testing etc. as required. |
113 | Overhauling of Ceiling Fan i/c dismantling, heat varnishing of windings, greasing of bearings, refitting, testing etc. as required. |
114 | Replacement of the defective Capacitors / Fan regulators/ bearings for ceiling fans etc. by the new one of following ratings etc. as required. (Make- Anchor/Havells/Cona/ISI) |
115 | Stepped type Electronic Fan Regulator (Switch type) |
116 | Modular Fan Regulator (2 Modules) |
117 | Modular Fan Regulator (1 Module) |
118 | 2.25 mfd 440 volts Capacitor for Ceiling Fan |
119 | Bearings forCeilingfans (6201 & 6202) etc. as required. (Make: SKF/SS) |
120 | Ceiling Fan clamps heavy duty mild steel zinc golden colour with rubber (Shackle set) |
121 | Dismantling of ceiling fan and painting the same with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent, reinstalling the same as required. |
122 | S/F of MCB protected Socket outlet 4 module with metal box comprising of 01no. 25Amps socket and 01no. 25Amps Plug and 01no. 25Amps "C" series SPMCB for Split AC units i/c connection, testing etc. as required. (Make- Legrand /Havells/HPL/Standard) |
123 | Replacement of burn out Sockets/lugs of cables by new ones of following types and sizes i/c dismantling the burnt out portion of cables/wires, crimping/fixingof new sockets/lugs etc. (Dowell"s / Comet / HexConnect well / SS) |
124 | For 4X16sqmm Al Conductor Armoured cable |
125 | For 3.5/4X25/35sqmm Al Conductor Armoured cable |
126 | For 3.5X50/70sqmm Al Conductor Armoured cable |
127 | Supply ofHot pressed molded SMC Junction box, hinged double door type of following sizes suitable for application for fixing Electrical controls /switch gears/meters etc. with provision for cable entry/exit from bottom/side ,locking arrangements including supply and fixing of 2nos4 pole stud connectors, interconnections with suitable sizesingle core PVC insulated copper conductor cable with copper sockets/lugs including fixing onexisting pole / existing MS/GI angle stands etc. complete as required. |
128 | Size not less than 650mmX350mmX250mm (inside dimensions) (Make-Sintex model: SINTEX JB-6535/SS) |
129 | Size not less than 400mmX300mmX190mm (inside dimensions) (Make-Sintex model: SINTEX JB-4030/SS) |
130 | Making suitable angle base frame made of 40mmX40mmX5mm MS angle for installation ofmentionedSMC junction / meter boxes ,cutting, welding, fabricating, grouting the same on ground with required PCC workcomplete as required. |
131 | Supply and fixing of SMC Junction box of size 200mm x 140mm x 95mm (inside dimensions) with hinged door type including supply and fixing of 1no. 4 pole stud connector with nuts and bolts etc. as required. (Sintex GSJB2014/SS) |
132 | Liaison with the Electricity DISCOMs for taking shutdown of LT/MV lines for checking, testing and replacement of faulty Service connection cable/Energy Meter/ Meter box/Feeder panel etc. and re energization of power supply after replacement of faulty components as above / removal of faults etc. complete as required. |