BOQ Items

Name of Work : ,s"kckx b.MfLVª;y ,fj;k ;kstuk ds vUrxZr Hkw[k.M la0&1 ij lkeqnkf;d dsUnz fuekZ.k dk;ZA
Sl. No. Item Description
1Community Centre
2EARTH WORK
3Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the
4All Kinds of soil
5Filling of Carted Earth (including loyality) by mechanical transport upto a lead of 5kmin trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lift upto 1.5 m.
6Supplying and filling in plinth with Sand under floors, including watering, ramming, consolidating and dressing complete.
7Supplying chemical emulsion in sealed containers including delivery as specified.
8Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
9Diluting and injecting chemical emulsion forPOSTCONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / Sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete:
10With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
11CONCRETE WORK
12Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level.
131:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size)
14Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
15R.C.C WORK
16Steel Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Upto plinth level
17Thermo-Mechanically Treated bars of grade Fe-500D or more.
18Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but including the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 Kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).
19All work upto plinth level
20All work from plinth level upto floor V level.
21Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
22BRICK WORK
23Brick work with common burnt clay (non modular) bricks of class -150in foundation and plinth in:
24Cement mortar 1:6 (1 cement : 6 coarse sand)
25Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
26Brick work with common burnt clay (non modular) bricks of class -150in superstructure above plinth level upto floor V level in all shapes and sizes
27Cement mortar 1:6 (1 Cement : 6 coarse sand)
28Half brick masonry with common burnt clay (non modular) bricks of class -150, in super structure above plinth and upto floor V level.
29Cement mortar 1 : 3 (1 cement : 3 coarse sand)
30Extra for providing and placing in position 2 Nos. 6 mm dia M.S. bars at every third course of half brick masonry.
31CLADDING WORK
32Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
33Area of slab over 0.50 sqm
34Providing and Fixing Ist quality ceramic glazed wall tiles conforming to IS :15622 (thickness to be specified by the manufacturer), of approved make in all colours, shades except burgundy, bottle green,black of any size as approved by Engineer-in-charge, in skirting, risers of steps and dados, over 12mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm , including pointing in white cement mixed with pigments of matching shade complete.
35Wood Work
36Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
37Second Class Teak wood
38Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately)
39Second class teak wood-30 mm thick shutters
40Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
41(35mm thick)
42Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.
431.0 mm thick
44Providing and fixing ISI marked Stainless Steel sliding door bolts with nuts and screws etc. complete.
45250x16mm
46Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
47200x10mm
48Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete :
49100mm
50Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made
51Using R4 series with frame (64mm & above) x (45mm & above) & sash (44mm & above) x (85mm & above). (Height above 2.5 meter).
52Using R3 series with frame (55mm & above ) x (45mm & above) & sash /mullion (55mm & above) x (65mm & above). (Height above 1.2 meter)
53Float glass panes 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm).
54Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4mm wide aperture on both side
55Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
56Providing and fixing to existing door frames. 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames
57Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.
58Using M.S. angels 40x40x6 mm for diagonal braces
59Providing And Fixing 12 mm frameless toughned glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangementand making necessary holes etc. for fixing required door fitting, all complete as per direction of Engineer-in-Charge.
60STEEL WORK
61Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
62Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
63Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.
64M.S. Tube
65FLOORING WORK
66Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete.
67Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
68Size of Tile 600x600 mm
69Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
70Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent
71FINISHING WORK
7212 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
736 mm cement plaster to ceiling of mix : 1:3 (1 Cement : 3 fine sand)
7415 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand)
75Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
76Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
77Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
78Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : One Priming coat & once coat oil distemper on new work including supply of all materials,labour and T & P etc. required for proper completion of the work
79Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer"s specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work
80Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required Length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction,including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs 12.5 mm thick tapered edge gypsum moisture resistant board at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer"s specification and also including the cost of making openings for light fittings, grills,diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
81WATER PROOFING
82Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
83Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compoundconsisting of applying:
84after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.
85laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.
86third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.
87fourth and final layer of brick tiling with cement mortar (which will be paid for separately).
88For the purpose of measurement the entire treated surface will be measured.
89Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:
90(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS 2845 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment
91(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement 5 coarse sand) admixed with water proofing compound conforming to IS: 2845 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs
92(c) After two days of proper curing applying a second coat of cernent slurry using 2.75 kg/ sam of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge.
93(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1) cement 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fibre cloth With average thickness of 120 mm and minimum thickness at khurra as 65 mm
94Peripheral Surrounding Floor (Building)
95Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the
96All Kinds of soil
97Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 Metre.
98Granular Sub-base with coarse graded material (table 400-2) Grade-I by mix in place. Construction of GSB by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix place methord with rotavator at OMC and compacting with vibratory power roller to achive the desired density as per MORT&H specification-401 complete in all respects.
99With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBRValue-30
100Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per MORT&H specification-406 complete in all respects.
101S/F 60 mm thick rubber moulded Interlocking tile etc. including supply of all labour material T&P etc all completed of work.
102Guard Room
103EARTH WORK
104Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the
105All Kinds of soil
106Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete
107Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
108Diluting and injecting chemical emulsion forPOSTCONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / Sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete:
109With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
110CONCRETE WORK
111Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level.
1121:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size)
113Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
114R.C.C WORK
115Steel Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Upto plinth level
116Thermo-Mechanically Treated bars of grade Fe-500D or more.
117Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but including the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 Kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).
118All work upto plinth level
119All work from plinth level upto floor V level.
120BRICK WORK
121Brick work with common burnt clay (non modular) bricks of class -150in foundation and plinth in:
122Cement mortar 1:6 (1 cement : 6 coarse sand)
123Half brick masonry with non modular fly ash bricks of class designation 10, conformingio IS :12894, in super structure above plinth and upto floor V level.
124Cement mortar 1 : 4 (1 cement : 4 coarse sand)
125Extra for providing and placing in position 2 Nos. 6 mm dia M.S. bars at every third course of half brick masonry.
126Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately)
127CLADDING WORK
128Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3Kg per Sqm, including pointing in white cement mixed with pigment of matching shade complete.
129Wood Work
130Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
131200x10mm
132Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete :
133100mm
134Providing and fixing ISI marked Stainless Steel sliding door bolts with nuts and screws etc. complete.
135250x16mm
136Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
13735 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
138Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
139Frame size 65 x 150 mm
140Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/ cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)
14130 mm thick
142FLOORING WORK
143Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 Kg/ Sqmincluding pointing the joints with white cement and matching pigments etc., complete.
144Providing and laying Vitrified tiles in floor, dado/skirting with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622 , of approved brand & manufacturer, in dark colours and shade, laid with cement based high polymer modified quick set gold star tile adhesive (water based) conforming to IS : 15477, in average 10 mm thickness, including grouting of joints Grouting the joints of flooring tiles having joints of 3 mm width, using Polymer based grout mix of 0.70 kg of organic coated filler of desired shade, including filling/ grouting and finishing complete as per direction of Engineer-in-charge
145Double Charge Vitrified Tile of Polished finish of size
146Size of Tile 600 x 600 mm
147Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 Kg/ Sqm including grouting the joint with white cement & matching pigments etc. complete.
148Size of Tile 600 x 600 mm
149FINISHING WORK
15012 mm cement plaster of mix :
1511:6 (1 cement: 6 coarse sand)
1526 mm cement plaster to ceiling of mix :
1531:3 (1 Cement : 3 fine sand)
15415 mm cement plaster on rough side of single or half brick wall of mix:
1551:6 (1 cement: 6 coarse sand)
156Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:
157New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
158Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
159Two priming coat & Two coat oil distemper on new work including supply of all materials, labour and T&P etc. required for proper completion of the work.
160Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
161Painting or vanishing on iron works in small areas or new wood work with two coat of ready mixed priming paint & two coat of approved superior quality ready mixed paint of clear synthetic varnish including supply of all materials, labour and T&P etc. required for proper completion of work. Paint to be used should confirm to the I.S.I No. 103 1950
162Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mi0tred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
163Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
164Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :
1655.0 mm thick glass panes
166Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
167Fixed to steel windows by welding
168Grading roof for water proofing treatment with
169Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
170Shed
171EARTH WORK
172Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the
173All Kinds of soil
174Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
175Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete
176Supplying chemical emulsion in sealed containers including delivery as specified.
177Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
178Diluting and injecting chemical emulsion forPOSTCONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / Sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete:
179With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
180CONCRETE WORK
181Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level.
1821:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size)
183Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
184R.C.C WORK
185Steel Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Upto plinth level
186Thermo-Mechanically Treated bars of grade Fe-500D or more.
187Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but including the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 Kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).
188All work upto plinth level
189All work from plinth level upto floor V level.
190BRICK WORK
191Brick work with common burnt clay (non modular) bricks of class -150in foundation and plinth in:
192Cement mortar 1:6 (1 cement : 6 coarse sand)
193Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
194In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
195Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
196FLOORING WORK
197Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
19825 mm thick
199FINISHING WORK
20015 mm cement plaster on rough side of single or half brick wall of mix:
2011:6 (1 cement: 6 coarse sand)
202Finishing walls with Acrylic Smooth exterior paint of required shade :
203New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
204Cement Concrete Road
205Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
206All Kinds of soil
207Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 Metre.
208Granular Sub-base with coarse graded material (table 400-2) Grade-I by mix in place.Construction of GSB by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix place methord with rotavator at OMC and compacting with vibratory power roller to achive the desired density as per MORT&H specification-401 complete in all respects.
209With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBRValue-30
210Construction of dry lean cement concrete sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineer-in- charge
211Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
212(Note:- Cement content considered in this item is @ 386 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately).
213Steel Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Upto plinth level
214Thermo-Mechanically Treated bars of grade Fe-500D or more.
215Providing and laying in position bitumen hot sealing compound for expansion joints etc.
216Using grade "A" sealing compound.
217Retro-Reflwctive Sheeting Type-IV with 4 mm thick Acm Double Side: Providing & fixing of Reflective signs with a corrosion resistant 4 mm thick with 0.4 to 0.5 mm both side aluminium skin aluminium composit panel face to be fully covered with high intensity prismatic sheeting typeIV as per IRC-67:2012 retro reflective sheeting with back frame MS angle of 35x35x5mm, Legends, Letter, Numerals andborders etc should be as per Morth specification No-801 3.7. The Sheeting manufacture. The ACM(Aluminium Composite Materials) shall be fixed on the back frame MS Angle with riveting Micro Prismatic type IV Retro reflective sheeting confirming to ASTM D4956-09 shall be pressure fixed. The Retro reflective sheeting be tested for a certificate of having the sheeting tested for coeficient of retro reflection, daytime colour and luminace, shrinkage, flexbility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 year outdoor weathering and its having passed these tests shall be obtained from international/Government Laboratory/institiute by the manufacturer of the sheeting and in case the certificate is abtained from intemetional condition, it should also be obtained from indian condition with in 3 years of launching of product by the manufacture in abroad, Alternatively, a certificate confirming to ASTM soecification (D4956-09) on artificial accelerated weathering requirements from a reputed laboratory in india can be accepted provisionally. In such a situation, the Employer/Client, if so desires, could seek for a performance guarantee which would be releaesd after receipt of certificate meeting the requirement of 3 years outdoor weathering of the sheeting as per IRC 67:2012 & Proof of the same Report shall be uploaded which quoting lender. The rate shall include all materials, labour, T&P, Transportation installationand incidentals all complete as per direction of the Engineer-in-charge.
218Manufacturing, supplying and fixing retro reflective overhead signage boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type - III of ASTM-D-4956-01 as approved by Engineer-in-charge, letters, borders etc. as per IRC : 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineer-in-charge.(Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment).
219Overhead informatory road signage
220Providing Retro-reflective regulatory sign board of size 900 mm dia Metre made out of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated lens type retro -reflective sheeting as approved by Engineer-in-charge . Letter, symbols, borders etc. will be as per IRC - 67 with required colour scheme on the boards and with the high intensity grade A. The aluminium sheet to be riveted to M.S. frame of angle iron of size 40x40x4 mm. The boards will be fixed to 1 No. 50x50 mm square post made of M.S. angle 50x50x4 mm, 4 m long welded to the frame with adequate anti-theft arrangement .Sheet work to be painted with two or more coats of synthetic enamel paint over an under coat (primer) and back side of aluminium sheet to be painted with two or more coats of epoxy paint including appropriate priming coat complete in all respects as per direction of Engineer-in charge.
221Pathway & Parking
222Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the
223All Kinds of soil
224Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 Metre.
225Granular Sub-base with coarse graded material (table 400-2) Grade-I by mix in place. Construction of GSB by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix place methord with rotavator at OMC and compacting with vibratory power roller to achive the desired density as per MORT&H specification-401 complete in all respects.
226With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBRValue-30
227Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per MORT&H specification-406 complete in all respects.
228Providing & Laying of Interlocking concrete block pavement having thickness 60 mm as per drawings and technical specification Clause 1504
229Providing & Laying of Interlocking concrete block pavement having thickness 80 mm as per drawings and technical specification Clause 1504
2301:1½:3 (1 Cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
231Boundary Wall
232Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lifts up to 1.5 m. including getting out the excavated soil and disposal of surplus excavated soil within a lead of 50 m. - in ordinary soil .
233Providing and laying Cement Concrete 1 :5 : 10(1 Cement : 5Fine sand : 10 graded brick agg.40 mm. nominal size) with cost of Centring and shuttering in foundation and plinth.including supply of all materials, labour, T & P etc. required for proper completion of the work.
234Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but including the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 Kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).
235All work upto plinth level
236All work above plinth level
237Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
238Brick work with common burnt clay (non modular) bricks of class -150in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)
239Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in :
240Cement mortar 1:6 (1 Cement : 6 coarse sand)
241Finishing wall with water proof cement paint of approved make such as super snowcem, Durocem, Robiacem, Guttucem, Supercem quality and of required shade on undecorated wall surface (one coat) over and including one coat white cement primer to give an even shade after throughly brushing the surface to powdered materials incFinishing wallluding curing and cost of the materials.
242Making Groove in plaster 10 to 12 mm wide x 8mm deep in plaster vertically or horizontally as required .
243ENTRANCE GATE
244Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
245In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
246Painting or vanishing on iron works in small areas or new wood work with two coat of ready mixed priming paint & two coat of approved superior quality ready mixed paint of clear synthetic varnish including supply of all materials, labour and T&P etc. required for proper completion of work. Paint to be used should confirm to the I.S.I No. 103 1950
247UG Tank
248EARTH WORK
249Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the
250All Kinds of soil
251CONCRETE WORK
252Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level.
2531:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size)
254R.C.C WORK
255Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 Kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).
256All work upto plinth level
257All work from plinth level upto floor V level.
258Steel Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Upto plinth level
259Thermo-Mechanically Treated bars of grade Fe-500D or more.
260BRICK WORK
261Brick work with common burnt clay (non modular) bricks of class -150in superstructure above plinth level upto floor V level in all shapes and sizes
262Cement mortar 1:6 (1 Cement : 6 coarse sand)
263WOOD WORK
264Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
265(35mm thick)
266Providing and fixing ISI marked Stainless Steel sliding door bolts with nuts and screws etc. complete.
267250x16mm
268Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete :
269100mm
270STEEL WORK
271Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:
272Profile B
273Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately)
274FLOORING WORK
27562 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 Kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
276Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.
27718 mm thick
278FINISHING WORK
27912 mm cement plaster of mix :
2801:6 (1 cement: 6 coarse sand)
2816 mm cement plaster to ceiling of mix :
2821:3 (1 Cement : 3 fine sand)
283Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
284White washing with lime to give an even shade :
285New work (three or more coats)
286WATER PROOFING
287Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compoundconsisting of applying:
288after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.
289laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.
290third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.
291fourth and final layer of brick tiling with cement mortar (which will be paid for separately).
292For the purpose of measurement the entire treated surface will be measured.
293Landscaping & Horticulture
294Supplying and stacking of good earth at site including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment).
295Supplying and stacking sludge at site including royalty and carriage upto 5 km complete (sludge measured in stacks will be reduced by 8% for payment).
296Supplying and stacking at site dump manure from approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment) :
297Screened through sieve of I.S. designation 20 mm
298Fine dressing of the ground.
299Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).
300Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge
301Grassing with selection No. 1 grass including watering and maintenance of the lawn for 60 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and earth shall be paid for separately).
302In rows 5 cm apart in both directions
303Trees/Plants
304Providing and displaying of Aglaonema Silver Queen having 30 cm to 45 cm. ht. with 12 to 15 leaves, multi suckers, fresh and healthy leaves, well developed in 25 cm dia Earthen pot/Plastic pot & as per direction of the officer-in-charge.
305Providing and displaying of Araucaria cookie having ht. 60 cm to 75 cm, straight, well developed, fresh and healthy with lush green leaves from bottom to top in 20 cm size of Earthen pot/Plastic pot. & as per direction of the officer-in-charge.
306Providing and displaying of Dracaena Song of India (three in one), having ht. 30 cm and above, multibranched, well developed with fresh and healthy leaves in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge
307Providing and displaying of Money Broad Leaves mounted on moss stick 1.20 m ht., 5 to 6 s in each pot, well developed with full of fresh & healthy leaves in size of 25 cm Top dia x 18 cm Bottom dia x 25 cm Perpendicular height Earthen pot/Plastic pot & as per direction of the officer-in-charge.
308Providing of Schefflera Green (three in one), mounted on moss stick 90 cm, well developed with full of fresh & healthy leaves from bottom to top with rich foliage in 25 cm size of Earthen pot/Plastic pot.as per direction of officer-in-charge.
309Providing and stacking of Cassia biflora of height 45-60 cm. in earthen pots of size 20 cm as per direction of the officer-in-charge.
310Providing and stacking of Euphorbia caracasana (bronze colour leaves) of height 60-75 cm. with 2-3 branches in earthen pots of size 20 cm as per direction of the officer-in-charge.
311Providing and stacking of Hamelia patens of height 30-45 cm. with 3-4 branches in poly bags of size 20 cm as per direction of the officer-in-charge.
312Providing and stacking of Plumbego capensis well developed with fresh and healthy 30 to 45 cm ht., with bloom in 20 cm Earthen Pot/Plastic Pot as per direction of the officer-in-charge.
313Providing and stacking of Tecoma gaudichaudi of height 45-60 cm. in earthen pots of size 20 cm as per direction of the officer-in-charge.
314Providing and stacking of Nyctanthes arbor-tristis (Hasingar) of ht. 90-105 cm in Earthen pots of size 20 cm as per direction of the officer-in-charge.
315Providing and Displaying Furcaria Variegated hybrid well developed with fresh & healthy foliage 20 and above attractive leaves in 35 cm Cement Pot as per direction of the officer-in-charge.
316Providing and Displaying Ficus Long Island topiary well developed with fresh & healthy 5 to 6 ball specific size and shape 120 to 150 cm ht in 40 cm Cement Pot as per direction of the officer-in-charge.
317Providing and Displaying Ficus nuda topiary well developed with fresh & healthy foliage 45 to 60cm spread 75 to 90 cm ht. bushy in 35 cm Cement Pot as per direction of the officer-in-charge.
318Providing and Displaying Ficus reginold well developed fresh & healthy foliage 60 to 75 cm spread 105 to 120 cm ht., Bushy in 35 cm Cement Pot as per direction of the officer-in-charge.
319Providing and Displaying Cyprus golden well shaped developed with good colored foliage fresh & healthy 60 to 75 cm ht in 30 cm Earthen Pot as per direction of the officer-in-charge.
320Providing and Displaying Cyprus Golden 30 to 45 cm ht. well developed good Golden colour foliage, Conial Shape in 25 cm Earthen Pots as per direction of the officer-in-charge.
321Providing and stacking of Callistemon lanceolatus of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
322Providing and stacking of Caesalpinia pulcherrima species of height 45-60 cm. in earthen pot of size 20 cm as per direction of the officer-in-charge.
323Providing and stacking of Calliandra hybrida of height 75-90 cm. with 4-5 branches in bag of size 25 cm as per direction of the officer-in-charge.
324Providing and stacking of Azadirachta indica ( Neem ) of height 120-130cm in big polybag of size 25 cm as per direction of the officer-in-charge.
325Providing and stacking of Bauhinia blakeana (Kachnar) of height 120-150 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge
326Providing and stacking of Polyalthia longifolia (Ashok) of height 180-195cm. in gunny bag of size 30 cm as per direction of the officer-in-charge.
327Providing and stacking of Euphorbia milli hybrid variety, having ht. 30 cm to 45 cm with multi branch, full bloom, fresh and healthy leaves in 30 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge..
328Providing and stacking of Ophiopogon jaburan ( variegated ),full of variegated leaves in Earthen Pot/Plastic Pot of size 20 cm. as per direction of the officer-in-charge.
329Providing and stacking of Iresine herbstii, of height 25-30 cm., full of branches well developed in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.
330Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water)
331Tree Plant
332Shrubs Plant
333Supplying & Stacking of Selection No.1/doob grass at site fresh & free from weeds having proper roots in green including loading, unloading, carriage and all taxes paid etc.and as per direction of officer in charge.
334Plumbing Work
335Sanitary Installation and CP fittings
336Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and floors wherever required :
337White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests
338Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
339W.C. pan with ISI marked white solid plastic seat and lid
340Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :
341White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
342Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-
343(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
344Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings
345Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
346Semi rigid pipe
34740 mm dia
348Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
349Providing and fixing Stainless Steel AISI 304(18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40mm including painting of fittings and brackets, cutting and making good the walls wherrerever required.
350Kitchen sink with drain board Size 510x1040 mm bowl depth 250mm
351Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge
352Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth.
353Granite Stone of approved shade
354CP Brass fittings
355Providing and fixing unplasticised PVC connection pipe with brass unions
35645 cm length
35715 mm nominal bore
358Providing and fixing in position best Indian Health Faucet with 8mm dia 1 meter long Flexible Tube and wall bracket with N. R. V. (non-return wall).
359Providing and fixing C.P. brass bib cock of approved quality conforming to IS:893115 mm nominal bore
360Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards andweighing not less than 690 gms. 15 mm nominal bore( for sink)
361Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:893115 mm nominal bore
362Providing and fixing C.P. brass sink mixer of approved quality and make conforming to IS: specification. 15 mm nominal bore
363Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (For bath) .15 mm nominal bore
364Providing and fixing C.P. brass shower rose with 15 or 20mm inlet
365150 mm diameter
366Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS: 8931. 15 mm nominal bore
367Providing and fixing CP Brass 40 mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge
368Providing and fixing toilet paper holder : C.P. brass
369Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
370Providing and fixing Ultra Thin Stainless Steel Hand Dryer (Heavy DutyEH 24S) of approved quality & make and as per the direction of Engineer-in-charge.
371Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
372450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
373CI soil watse and Vent Pipe
374Providing & fixing soil, waste and vent pipes.
37575 mm dia with wall thickness of 3.5 mm
376100 mm dia with wall thickness of 3.5mm
377150 mm dia Hubless cast iron pipes including fittings
378Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe
37975 MM SS 304 grade coupling with EPDM rubber gasket
380100 MM SS 304 grade coupling with EPDM rubber gasket
381150 MM SS 304 grade coupling with EPDM rubber gasket
382Cutting holes up to 30x30 cm in walls including making good the same: With With common burnt clay F.P.S. (non modular) bricks
383Cutting holes up to 15x15 cm in R.C.C. floors androofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof
384Providing and fixing UPVCpipes complete with fittings and clamps, including cutting and making good walls etc. ( for wash basin & Urinal waste )
38540 mm dia nominal bore
386Providing and fixing upvc hooper
387Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. :
388100mm dia pipe.
389Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :
390a) 100mm inlet & 100mm outlet.
391b) 100mm inlet & 75mm outlet.
392Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.
393100mm
39475mm
395Providing and fixing plain bend of required degree.
396a) 100mm
397b) 75mm
398Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.
399100x100x100mm
40075x75x75mm
401Providing and fixing centrifugaly cast iron single equal plain junction of required degree.
402100x100x100mm
40375x75x75mm
404Providing and fixing single unequal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete :
405100x100x75mm
406Providing and fixing single unequal plain invert branch of required degree :
407100x100x75mm
408Providing and fixing 150X150X100 Y Band withincluding fittings complete.
409Providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete :( c.o.p.)
410100mm
41175mm
412Providing and fixing END CAP withincluding fittings complete.
413Providing and fixingcast iron terminal guard.
414100 mm
415Internal rain water drainage work
416Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size)around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground)
417110 mm dia
418Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion.
419110 mm
420Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.
421Coupler
422110 mm
423Single tee without door
424110x110x75
425Bend 87.5 degree
426110 mm Bend
427Shoe (Plain)
428110 mm Shoe
429Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
430Providing and fixing 100 mm/110 mm diameter and 60 cm long rain water spout in cement mortar 1:4 (1 cement : 4 sand)
431Upvc spout (Pipe dia.110 mm)
432Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. :
433100 mm
434Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.
435Internal water supply
436Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.
437Concealed work including cutting chases and making good the walls etc.
43820mm dia nominal outer dia pipes
43925mm dia nominal outer dia pipes
44032mm dia nominal outer dia pipes
441Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe withclamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge..
442Internal work-Exposed on wall
44320mm dianominal bore
44425mm dia nominal bore
44532mm dia nominal bore
44640mm dia nominal bore
44750mm dia nominal bore
44865mm dia nominal bore
44980mm dia nominal bore
450Providing and fixing gun metal gate valve with wheel of approved quality.
45120mm dia nominal bore
45225mm dia nominal bore
45332mm dia nominal bore
45440mm dia nominal bore
45550mm dia nominal bore
45665mm dia nominal bore
45780mm dia nominal bore
458Providing and fixingButterfly Valve with IP 54 actuatorwith Control Panel and Two Point Magnetic Sensor for Automated Tank Filling System
45932 mm nominal bore
460RO Plant and drinking water
461RO Plant 250 LPH (Liter per hour)
462PLANT CAPACITY - 250 LPH Treated Water Quality Turbidity : <1NTU pH : 6.5-7.0 Chlorides : < 10 ppm Sulphates : < 5 ppm TDS : < 150 ppm
463500L STORAGE TANK AND DRINKINGFOUNTAIN
464Supply installation, testing and commissioning of water cooler Cooling Capacity150Ltrs. / Hrs.,Storage Capacity 150 Ltrs
465External sewage system
466Excavating trenches in all kinds ofsoil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m.
467up to 1.50 m depth
468Pipes 80 mm to 300 mmdiameter
469Opentimbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered)
470Depth not exceeding 1.5 meter
471Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete.
472100 mm.dia. RCCPipes
473150 mm.dia. RCCPipes
474Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design
475100 mm.dia. RCCPipes
476150 mm.dia. RCCPipes
477Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design
478150 x 100 mm size P type
479With Sewer bricks conforming to IS : 4885
480Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 sand ) R.C.C. top slab with Cement Concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stoneaggregate 20mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design
481Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).
482With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
483Extra for depth for manholes:
484Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5
485External rain water drainage system
486Excavating trenches in all kinds ofsoil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m.
487up to 1.50 m depth
488Pipes 80 mm to 300 mmdiameter
489Opentimbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered)
490Depth not exceeding 1.5 meter
491Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete.
492150 mm.dia. RCCPipes
493Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design
494150 mm. dia.
495Constructing brick masonry INSPECTION chamber 60x60x90 cm with bricks of class designation 50 in cement mortar 1:4 (1 cement : 4 coarse sand) including CI cover with frame LIGHT WEIGHT complete as perdesign. With FPS bricks
496Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 sand ) R.C.C. top slab with Cement Concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stoneaggregate 20mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design
497Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).
498With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
499Extra for depth for manholes:
500Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5
501Providing orange colour safety footrests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture"s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
502External water supply
503Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
50425mm dia nominal bore
50532mm dia nominal bore
50665mm dia nominal bore
507Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc.
50825mm nominal bore.
50932mm nominal bore.
51065mm nominal bore.
511Provding and fixing C.I. Double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc. if required will be paid separately.
51250mm dia
513Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement :2 sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement :5 sand:10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement :3 sand) 12mm thick finished with a floating coat of neat cement complete asper standard design :-
514With common burnt clay bricks of 25 kg /sqcm compressive strength
515Domestic pump Hydro-Pneumatic Booster System Parallel Pumping System Numbers of Pump in System: 3 Pump Version: Cast Iron & S.S AISI 304 Seal Material: Carbon/SiC/SS316/EPDM Bearing Material: Ceramic/Tungsten Carbide Rubber Parts: NBR (Nitrile) Mounting: IEC Enclosure: TEFC Phase: 3 Voltage: 380-415V Efficiency Class: IE1 MotorSystem Components Accessories: Included Header Flange Rating: PN 16 Pump Controller: Single VFD with HMI & PLC HPN Pressure Tank: 200 litre
516Flow Rate-150 lpm
5172 Working + 1 Stand By
518Head 65 m
519IRRIGATION PUMP
520Supplying & installation of approved make required capacity 3 phase, 50 Hz, 415V, centrifugal mono-block pump, with starter i/c single phase preventer, connections, base channel foundation etc. as required as per specifications but excluding pipe and connection cable.
5217.5 HP head metre 24-37, discharge LPM 250-320
522Pump Room for Sump Pump
5231 Phase open well submersible pump
524Supplying &installation of approved make required capacity single phase, 50 Hz, 230V, open well submersible pump, with control panel starter with dry run protection, connections, etc. as required as per specifications but excluding pipe and connection cable.
5252.0 HP head metre 14-24, discharge LPM 342-138
526Domestic & Flushing Pump Panel
527Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panelMCCB"s (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A & B only.
528Same as above item but following mountings.
529INCOMER:-
5301 Nos. 125 Amps. 4P MCCB (25 KA)
5311 Set phase indication lights (R, Y, B)
5321 No. Volt Meter (digital type) with inbuilt VSS & control fuses.
5331 No. 0-125 Amp. Ammeter (digital type) with inbuilt ASS
534BUS BARS:-
535200 Amps. TP&N aluminium bus bars
536OUT GOINGS:-
5376 Nos. 40 Amps. TPN MCCB (15 KA) - To Pumps
5386 Nos. 40 Amps. TPN MCCB (15 KA) - SPARE
539Extrnal drain channel sysytem
540Constructing RCC precast perforated RCC. slab covered Drain with 150mm thick RCC 1.1.5.3 ( 1 cement : 1.5 fine sand : 3 graded stone aggregate 20mm nominal size) wallincluding earth excavation, 75mm thick bed concrete 1:4:8 (1 cement : 4 fine sand : 8 graded stone aggregate 40mm nominal size) and 100mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) for filling haunches including 12mm cement plaster 1:4 (1 cement : 4 coarse sand ) with a floating coat of neat cement inside the drain, its top and exposed side including disposal of surplus earth complete as per standard design:
541Drain 300 wide average.Depth 500cm with R.C.C. Slab
542Bore well
543Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level.
544All types of soil
545400 mm dia
546Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.
547All types of soil
548400 mm dia
549Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/ plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge.
550200 mm nominal size dia having minimum wall thickness 5.00 mm.
551Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed / plain bevel ended pipe (type A) of required dia, conforming to IS:8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge.
552150 mm nominal size dia
553Providing and fixing in 200X150 ERW Pipe Reducer including fittings complete.
554Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:
555200mm nominal size dia
556Providing and fixing M.S. clamp of required dia made of 100 x10 mm flat to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts and nuts of required size complete.
557150mm nominal size dia
558200mm nominal size dia
559Providing and fixing Bail plug / Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).
560250mm nominal size dia
561Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
562Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
563Providing and fixing 80 dia G.I. column pipes complete with G.I. fittings including trenching and refilling etc.
564Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) :
56580 mm dia
566Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately)
56780 mm dia
568Providing and fixing gun metal gate valve with C.I.wheel of approved quality (screwed end) :
56980 mm dia
570Providing and fixing gun metal non- return valve of approved quality (screwed end) :
57180 mm dia
572Submersible Pumpinclude the rate of electrical control panels complete with all accessories &controls, all Electrical/Mechanical items as required to operate the system automatic/manual.
573c) Level Controller with sufficient nos. of low / high level alarms, contacts with electrodes and control wiring for the automatic operation of water supply pumps, Submersible Sump Pumps, to achieve the functional requirement shall be provided. Control wiring between these pumps and water tanks shall be provided.Domestic water pumps must start at low water level inunder grounddomestic water tank & stop at high level in that water tank. Dry running protection shall be provided for all the pumps.Sequencing shall be provided for each set of pumps.
574Supplying & Installation of(400 lpm and 75 mtr head) submersiblestarter and cable(L&T or BCH make) etc of approved make, and all accessories complete as per requirement of site.
575RAIN WATER HARVESTING
576RECHARGE PITS
577Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
578All kinds of soil
579Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.
580Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
5811:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stoneaggregate 20 mm nominal size) M-15 – Grade concrete
582Brick work with well brunt open bhatta, bricks, crushing strength not less than 25kg /cm2 and water absorption not more than 20% in foundation and plinth i/c curing etc complete
583Cement mortar 1:4 (1 cement : 4 coarse sand)
584Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
585M-20 Grade Concrete
586Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
587Thermo-Mechanically Treated bars of grade Fe-500D or more.
58812 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
589Centering and shuttering including strutting, propping etc. and remova of form for :
590Foundations, footings, bases of columns, etc. for mass concrete
591Suspended floors, roofs, landings, balconies and access platform
592Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:
593With 20x20mm square bar
594Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.
595M.D. -10- Circular shape 500mm internal diameter
596Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.
597Drilling of 300mm dia bore hole manually.
598Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
599150 mm nominal size dia
600Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
601Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
602Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.
603Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
604DESILTING CHAMBER
605Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
606All kinds of soil
607Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.
608Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
6091:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stoneaggregate 20 mm nominal size) M-15 – Grade concrete
610Brick work with well brunt open bhatta, bricks, crushing strength not less than 25kg /cm2 and water absorption not more than 20% in foundation and plinth i/c curing etc complete
611Cement mortar 1:4 (1 cement : 4 coarse sand)
612Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
613M-20 Grade Concrete
614Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detalingIS 456 RCC Design & SP 34 Reinforcement detailing ) etc. complete . (Note:- 1. Spacer bars (chairs) shall be paid separately as shown in the drawing and as per direction of engineer in charge. 2. No extra payment shall be done for overlaps and/or couplers. 3.Couplers shall be conforming to IS code on “Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement - Specification”)
615Thermo-Mechanically Treated bars.FE 500 or more conforming to IS 1786
61612 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
617Centering and shuttering including strutting, propping etc. and remova of form for :
618Foundations, footings, bases of columns, etc. for mass concrete
619Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
620Suspended floors, roofs, landings, balconies and access platform
621Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:
622With 20x20mm square bar
623Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.
624M.D. -10- Circular shape 500mm internal diameter
625Electrical works
626Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
627Group B
628Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
629Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
630Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
6312 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
6322 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
6332 X 6 sq. mm + 1 X 6 sq. mm earth wire
6342 X 10 sq. mm + 1 X 6 sq. mm earth wire
6354 X 6 sq. mm + 2 X 6 sq. mm earth wire
6364 X 10 sq. mm + 2 X 6 sq. mm earth wire
637Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
638Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
639Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
640Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
64120 mm
64225 mm
64332 mm
644Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
645Supplying and fixing brass batten/ angle holder including connection etc. as required.
646Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
647Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc.
6481 or 2 Module (75mmX75mm)
649Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
650Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
651Telephone socket outlet
652TV antenna socket outlet
653Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
6541 Pair
655Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
6561 run of cable
657Supplying and drawingCo axial TV cable, RG-6 grade, 0.7 mm solid copper conductor, shieldedwith fine tinned copper braid and protected with PVCsheathin the existing surface/recessed steel/PVC conduit as required.
658Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required.
659100 mm dia
660Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.
661300 mm dia
662Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
663120 mm dia (OD-120 mm & ID-103 mm nominal)
664Lighting Fixtures (Lights/Fans) :
665Supply & fixing of single wall light bracket made of brass on matching polishedMDFEG boardbrassincludingconnectionetc. as required. CAT. AAA
666Supply and fixing of recess/surface/pendent mounting round 6 to 8 W LED Down lighiter having powder coated die cast aluminium housing with heat shink,diffuser/reflector and driver set. Complete in all respect. CAT. - AAA
667Supply and fixing of recess/surface mounting round 10 W to 15 W LED Cut out Min 125 mm, Height Min. 40mm, LED Down lighiter having powder coated die cast aluminium housing with heat shink,diffuser/reflector and driver set. suitable for 24Hr Continuous Operation, Complete in all respect. CAT. - AAA
668Supply and fixing of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect.CAT. - AAA
669Supply and fixing of water tight oblong 10 Watt LEDbulk head luminaire having die cast housing with driver set confirming to IP 65 and above Protection.Complete in all respect. CAT. - AAA
670Supply and fixing of 3 Watt LED Path / Walkover luminaire having powder cotated die cast aluminium body with drive set . Confirming to IP 65 Protection complete in all respect. CAT. - AAA
671Supply and fixing of 3 watt to 6 watt LED(spot light) fitting Confirming to IP 65 and above protection Complete in all respect. CAT. - AAA (Use as a Decorative Mirror Light)
672Supply of ceilling fans with fan motor of A.C. Permanent insulation, capacitor rating conforming BEE 5 Star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment. The rated voltage 220/240 volts,50 Hz, 1-Ph AC the fan assemble should consists of down rod blades, shackle canopies etc and with double ball bearing system.
673BEE 5 Star rated-1200 mm sweep
674Armoured Cables (Cable/Gland/Lug) :
675Supplying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size
676size 10 sq mm x 2 core
677size 10 sq mm x 4 core
678size 16 sq mm x 4 core
679size 25 sq mm x 3-1/2core
680size 35 sq mm x 3-1/2core
681size 50 sq mm x 3-1/2core
682size 150 sq mm x 3-1/2core
683size 185 sq mm x 3-1/2core
684Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
685Upto 35 sq. mm
686Above 35 sq. mm and upto 95 sq. mm
687Above 95 sq. mm and upto 185 sq. mm
688Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
689Upto 35 sq. mm
690Above 35 sq. mm and upto 95 sq. mm
691Above 95 sq. mm and upto 185 sq. mm
692Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
693Upto 35 sq. mm
694Above 35 sq. mm and upto 95 sq. mm
695Above 95 sq. mm and upto 185 sq. mm
696Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
697Upto 35 sq. mm (clamped with 1mm thick saddle)
698Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
699Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
700Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
7012 X 10 sq. mm (19mm)
7024 X 10 sq. mm (25mm)
7034 X 16 sq. mm (28mm)
7043½ X 25 sq. mm (28mm)
7053½ X 35 sq. mm (32mm)
7063½ X 50 sq. mm (35mm)
7073½ X 150 sq. mm (50mm)
7083½ X 185 sq. mm (57mm)
709Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
7103½ X 25 sq. mm
7113½ X 35 sq. mm
7123½ X 50 sq. mm
7133½ X 150 sq. mm
7143½ X 185 sq. mm
715Earthing Work :
716Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
717Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
718Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
719L.T. Switch Panel Board :
720Outdoor Feeder Panel -
721Supply& Erracetion of factory fabricated & wired metal clad dust and weather proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCB"s (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects.
722The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides.
723The MCCB"s shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicle type switch board shall be of cat A & B Only.
724LT Incomer -
725630A FP/50kA MCCB - 1 Sets
726DG Incomer -
727100A FP/25kA MCCB - 1 Sets
728SP Tapping -
72940A FP/15kA MCCB - 1 Sets
730Metering -
731VIF Meter showing all Volt Ampere & Frequency along with Phase Indicating Lights/Current Transformer/Control MCB etc.- 1 Sets
732Bus Coupler -
733100A FP/25kA MCCB - 1 Sets
734Bus Bar -
7351000A FP/25kA MCCB - 1 Set
736Outgoing -
737200 Amp FP MCCB - 1 Nos. (To Block Panel)
738400 Amp FP MCCB - 1 Nos. (To Fire Panel)
73940 Amp FP MCB - 1 Nos. (To SLCP)
74025 Amp DP MCB - 2 Nos. (To Shed & Security Room)
741100 Amp FP MCCB - 1 Nos. (Spare)
74263 Amp FP MCCB - 2 Nos. (Spare)
74340 A FP MCB - 4 No. (Spare)
744Block Panel -
745Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCB"s (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects.
746The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides.
747The MCCB"s shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicle type switch board shall be of cat A & B Only. CAT. B Cubicle Type
748Incoming -
749200 Amp MCCB-1 No.
750Outgoing -
75163 Amp FP MCB - 3 Nos. (To PDB)
75232 Amp FP MCB - 3 Nos. (To LDB)
75340 Amp FP MCCB - 4 Nos. (for VRV/VRF ODU)
75440 Amp FP MCB - 1 Nos. (Spare)
75563 Amp FP MCCB - 1 Nos. (Spare)
756DBs & MCBs :
757Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
758Single pole
759Double pole
760Triple pole and neutral
761Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
76263 A
763Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
7646 way , Double door
765Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
7666 way (4 + 18), Double door
7678 way (4 + 24), Double door
768Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
769Miscellaneous Items :
770Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
771Upto 450 mm sweep
772Supply and Fixing of shock treatment chart.prescribedas per I.E. Rules.duly framed with glass and supported from back with hard board or shoft board with supply of all material ,labour,T&P for proper completion of work.
773Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules
774S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work.
775Non-Schedule Items
776Supply & fixing of 12 Watt LED Bulb - B22 / E27 (Colour Temp.- 6500K / Lumens - 900 lm) cool day light, Input Volts (AC 90V-260V), 3-Star rating suitable for Batten/Angle holder including making connection.Complete in all respect.
777Supply & fixing of 225/230mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect.
778Supply & fixing of 300mm sweep ventilating (Medium Heavy Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Double ball bearing /Copper motor /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 70/85 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 900/1400 RPM. Complete in all respect.
779Supply & Fixing of LAN socket outlet modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. Complete in all respect.
780Supply and fixing of LED Highbay light Fitting having die cast aluminium body and diffuser with driver set suitable for 50 Watt. Confirming to IP 66 Protection complete in all respect.
781Fire Detection & Alarm System :
782Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required.
783Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.
784Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
785Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required.
786Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in ABS box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
787Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.
7884 Zone
789Fire Alarm Panel with Talk Back Syetm Arrangements :
790Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required.
79106 Zone panel for fire alarm system.
792100 Watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required - 1 No.
793Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos. talk back unit -1 Set.
794Annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc. complete as required -1 Set.
795Amplifier change over switch for inter changing amplifier -1 No. Monitor panel for loudspeaker complete with output selector, ON/OFF switch, fuse, visual indications etc. complete as required- 1 No.
796Gooseneck microphone with stand and ON/OFF switch- 1 No. Main ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters, terminal blocks etc. complete as required -1 Set.
797Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos. 12 volt, 30 AH Each sealed maintenance free batteries -1 Set.
798Supplying & laying of 2x1.5 Sqmtm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
799Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.
80013 Passenger Lift :
801Supply Installation, Testing & Commissioning of 13 Passangers, 884 Kg, 1.0 mps. Automatic Elevator, with VVVF and Microprocessor based Simplex Collective Selectivewith/without Provision ofattendant control. Separate Landing Push Button Box for all Landings with scrolling indicator. with provision of Attendant control , having 13 stops , 13 Openings , with SS Cabin (Hair Line Finish) havingCross flow fan for Ventillation , having sleek (SS hair Line finish-PVC) and LED small Circular lighting all complete.
802Other Features -
803Battery Operated Emergency Light/Fan and Alarm Bell
804VF Door Drive
805Fireman Control Switch.
806Infrared Screen for Doors
807Granite Flooring (Texture finalized by UPRNN)
808Dot Matrix Display for Direction & Position Indicators at all Landings.
8093 nos. SS Round Handrail for Passenger Elevator
810Automatic Rescue Device (ARD)
811Overload & Full Load Bypass
8121Hr Fire Rated Doors
813Intercom – 3 way intercom system
814Floor Announcement System in Car
815Vision panel provided as possible ( as per OEM standard).
816Provision of CCTV system in lift.
817Scaffolding
818Braille Buttons
819Sill Support
820Hoist Beam
821Trap Door
822Pit Ladder
823Minor Builders Work
824Lift License
825Free CMC for 5 Years.
826Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.
82763 A TP&N
828Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8298 way , Double door
830Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
831Triple pole and neutral
832Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB required.
83363 A
834CCTV System :
835SITC of 2 MP Dome Camera, 1/2.8" Progressive CMOS, ICR, 1920x1080: 25fps(P) / 30fps(N), H.265+/ H265/ H.264+ & H.264, 3D DNR, BLC, IR range: up to 30m, DC12V & PoE, Support mobile monitoring
836SITC of 2 MP Bullet Camera 1/2.8" Progressive CMOS, ICR, 1920x1080: 25fps(P) / 30fps(N), 2.8mm/F2.0 lens (4/6mm optional), H.265+/H265/H.264+ & H.264, IP67, DWDR, 3D DNR, BLC, IR range: up to 30m, DC12V & PoE,Support mobile monitoring
837Supply, Installation, Testing & Commissioning of 32 Channel Network Video Recorder with specifications as follow: Supported Image Format H.264+/H.264, H.265+/H.265, MPEG-4, JPEG, M-JPEG; Supported Image Resolution 1920x1080, 1,280 x 960, 960 x 720, 640 x 480, 320 x 240; Maximum Number of Cameras 32; RAID 5, 320MBps incoming bandwidth Camera Control Pan/Tilt, Zoom, Focus, Brightness, Preset position call and program (up to 256), Auto mode GUI REC/Playback Control REC, PLAY, Rev PLAY, Pause; Network Interface Camera port: 10Base-T / 100Base-TX Min 2x 8TB can be installed. Certification: UL, CE, BIS, FCC.
8384 Port POE Switch ,Unmanaged PoE, 4 100M PoE, 1 1000M PoE, 1 1000M SFP, 250m Transmission, 6KV Surge Protection,
83924 Port POE Switch ,Unmanaged PoE, 24 100M PoE, 1 1000M PoE, 1 1000M SFP, 250m Transmission, 6KV Surge Protection, 225W
840PVC Box for Camera
841RJ45 Connector Box( 100PC)
8422U Rack with complete accessories.
8439U Rack with complete accessories.
844D-Link 1 MTR Patch Cord
8458 TB Survillance Hard Disk
846Supply and laying of CAT 6 UTP cable
847Supply and laying of 25mm dia PVC conduit including accessories.
848Supply and laying of 3 core 1.5 sqmm copper unarmoured cable
849SITC of 49" flat screen FHD professional LED suitable for 24x7 operation with remote control and wall mount unit/floor stand complete with making connection etc as per list of approved makes.
850Supply, installation and testing of UPS 2 KVA capacity.
851Solar Power Plant :
852SITC of Grid Connected Rooftop Solar Power Plants including transportation, insurance, five year AMC/CMC and applicable fees and taxes.
853VRV/VRF AC System :
854Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%,3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5.
855Indoor Unit : (High Wall Type)
856Supply,installation,testing and commissioning of following minimum capacity VRV/VRF Highwall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multi speed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230V±10%, 50Hz, single phase AC supply, complete as required. The unit shall have automatic force shutdown provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.
8571.45 TR
8582 TR
859Indoor Unit : (Ductable Type)
860Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiveing signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.
861Mid Static Ductable Units (minimum 45 pascal external static pressure)
8624 TR
863Copper Refrigerant Piping :
864Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :
8656.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
8669.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
86712.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
86815.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
86919 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
87022.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
87125.4 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
87228.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
87338.1 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
87441.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
875Street Pole with LED Lamp :
876Supply & fixing of 6 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with Single Arm bracket 1 Mtr length in 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling and Required T&P completee in all respect.
877Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 110 to 130 Watt. Confirming to IP 66 Protection complete in all respect. CAT AAA
878Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
879Single pole
880Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.
8813 output (1output per phase) and suitable for three phase supply
882Supply & fixing of anticlimbing device fabricated from G.I.(flat) of 25 mm x 6mm size in a shape of ring of the pole size, having G.I. flat pointed fins of length 225 mm in 8 nos. including all the materials, labour, T&P and other material required for proper completion for work and to the satisfaction of Engineer-in-Charge.
883Supply and fixing of decorative 8 to 16 Watt LED bollard luminaire with driver set confirming to IP 65 protection complete in all respect. CAT. - AAA
884Cable etc. :
885Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Following size
886size 6 sq mm x 3 core
887size 10 sq mm x 4 core
888size 25 sq mm x 3-1/2core
889Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed, underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer -incharge.for cable
890size 6 sq mm x 3 core
891size 10 sq mm x 4 core
892size 25 sq mm x 3-1/2core
893Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable
894size 6 sq mm
895size 10 sq mm
896size 25 sq mm
897Earthing Work :
898Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required
899Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required
900Supplying & erecting water tight terminal box of cast iron of size 200 x 150 x 150 mm complete on pole.
901D.G. SET (62.5KVA) :
902Supply, Installation, Testing & Commissioning of 03 phase volts 50 cycle per second 1500 RPM air cooled, diesel generating set complete with silent type DG canopy & limiting sound level to 75 dB (A) over a distance of one meter with engine, alternator aircooled. The engine shall be complete with flywheel to suit flexible coupling with guard, air cleaner, fuel pump, fuel day tank, variable speed governor, fuel filter, lube oil filter, battery charging generator, voltage regulator, 24 volt charged voltage regulator, capacity and instrument panel comparing switch with key, space heater, lube oil temperature gauge, lube oil pressure gauge, water temperature gauge, battery charging ammeter, safety control for low lube oil pressure and hightemperaturetripping.
903Supplying, installation, testing and commissioning of Silent Type DG Sets,AMF Panel, Bus Ducting/ Cables from DG Sets to Essential Panel, Synchronizing Panel where required, DG Set enclosure room sound insulation/ventilation/smoke exhaust as required, Earthing of DG Set system, control cabling, Fuel tank/piping, DG set Exhaust piping/Exhaust Chimney as per CPCB norms, Civil works connected with DG Sets including Foundation as required.
904DG Set Compatible for synchronising Panel
90562.5 KVA
906Supply and fixing of M.S. Fencing frame duly fabricated from M.S. angle iron 50mm x 50mm x 5mm /40mm x 40mm x 5mm with M.S. flat 40 x 6 mm with M.S. welded 10 SWG, Mesh Jali best quality 25 x 25 mm on fencing frame with 6 Nos. M.S. Fasteners of required size duly painted complete in all respects. The Fencing frame of different sizes as site requirement.
907Add Extra For RCC Foundation Work for D.G. Set Including Cost of Exaust Pipe with Structure and Other Misc. Work and T&P etc. Complete in all respect as per directed by Engineer In-Charge.
908Earthing System :
909Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
910Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
911Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as requiredide.
912Fire Fighting
913Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)
914(a)Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520
915b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-"F" insulation, conforming to IS-325.
916(c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.
917(d) Suitable cement concrete foundation duly plastered and with anti vibration pads.
918450 lpm at 35 m Head
919Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
920Air Release Valve, Gunmetal, having rubber ball with 1” (25mm) BSP Male threaded inlet
921Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
922Providing, laying,of "C" class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
923100 mm dia
924Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
925100 mm dia
926Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
927100mm dia
928Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
929INTERNAL HYDRANT
930Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :
931Single headed Gunmetal
932Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
933Gun Metal
934Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
93530 m
936Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
937Gun metal
938Fireman Axe-made of carbon steel with rubber insulated handle tested to 20,000 Volts as per IS:926 Make: NEWAGE
939Fire shaft door fabricated out of M.S. sheet and frame, door size of 1200 (W) x 2100 (h)with 4 mm thick glass, suitable Rubber beading and Locking arrangement and complete door shall be powder coated with red color powder coating
940Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :
9412 way-100 mm dia M.S. Pipe
942EXTERNAL FIRE Fighting
943Providing, storing, handling, shifting, installation, testing and commissioning of halon free portable fire Extinguishers as described below:
944Co2 type Fire Extinguisher 4.5 Kgs. Capacity, made from brand new seamless cylinder, as per IS: 7285 and CCE approval, fitted with Discharge hose and horn and wheel type valve with initial Charge as per IS: 15683:2018 specification, bearing ISI Mark & EIL approved. Make: SAFEX
945Capacity 4.5KG
946Providing and fixing of ABC Power type fire extinguishers consisting of welded M.S. cylindrical body, squeeze lever discharge valve fitted with pressure indicating gauge internal discharge tube 30 cm long high pressure discharge hose, discharge nozzle, suspension bracket. Conforming to IS: 15683 finished externally with red enamel paint fixed to wall with brackets complete with internal charge.
947Capacity 6KG
948Providing and fixing Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate sizeincluding fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects as directed by Engineer-in-charge.
949FIRE CONTROL PANELS
950Supply installation, testing and commissioning of approved make DOL starter 7.5 hp, 3 phase, 50 Hz, 415V, i/c single phase preventer, incoming MCB 32A 4P, 10KA , in outdoor type enclosure, connections, as required as per specifications.
951Copper Power Cables, Solid Copper Conductor upto 6 sq. mm & Balance Stranded Copper, XLPE Insulated, Cores Laid Up, PVC Innersheathed, Unarmoured/Armoured (Glavanised wire for cables up to 10x1.5 sq. mm, 8x2.5 sq. mm, 2x10 sq. mm, 3x10 sq. mm, 4x6 sq. mm & balance all galvanised steel strip), Extruded PVC Type ST2 Outer Sheathed, 650/1100 V Grade as per IS 7098
9524 Core X 10 sqmm. Aluminium Armoured
953Supplying and making end termination with brass double compression gland and aluminium lugs for following size of XLPE insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. It should be complete as per specifications & directions of Engineer-in-charge.
9544 Core X 10 sqmm. Aluminium Armoured
955Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required
9566 C x 2.5 Sqmm
9572 C x 2.5 Sqmm
958Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
95925 mm Conduit
96032 mm Conduit
961150 mm width x 50mm depth x 1.6 mm thickness.
962EXTERNAL FIRE HYDRANT & FIRE PUMPS
963Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :
964(a)Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.
965(b)Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-"F" insulation, conforming to IS-325.
966(c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.
967(d)Suitable cement concrete foundation duly plastered
9681620 lpm at 56 m Head
969Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type,multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.
970Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.
971M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads.
9721620 lpm at 56 m Head
973Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.
974Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-"F" insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads.
975180 lpm at 56 m Head
976Supplying and fixing Air Vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
977Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
978Providing laying, testing & commissioning of "C" class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.
979150 mm. Dia
980Providing, laying, testing & commissioning of "C" class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
98180 mm dia
982100 mm dia
983150 mm dia
984Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :
98580 mm dia
986100 mm dia
987150 mm dia
988Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
98980 mm dia
990100 mm dia
991150 mm dia
992Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.
993200mm dia
994EXTERNAL HYDRANT SYSTEM
995Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required :
996Single headed Gunmetal
997Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
998Gun Metal
999Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
1000Gun metal
1001FRP Hose Box single door (750X600X250) Make: Safex
1002Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :
10034 way - 150 mm dia M.S. Pipe
1004FIRE CONTROL PANELS
1005Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :
1006400A, 50kA 4 Pole MCCB, Ics=100% Icu Rating Digital Voltmeter 0-500V with selector switch Ammeter (0-400 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 500Amps
1007Outgoings
1008Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)
1009Main Fire Pumps 125 Amp, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets
1010Jockey Pump 63 Amp, 50kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets
1011DIESEL ENGINE CONTROL Control for diesel engine comprising -Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification
1012Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc
10134 Core X 16 sqmm. Aluminium Armoured
10144 Core X 10 sqmm. Aluminium Armoured
10153.5Core X 50 sqmm. Aluminium Armoured
10163.5 Core, X 35 sqmm. Aluminium Armoured
10173.5 Corex 300 sqmm. Aluminium Armoured
10183.5 Corex 120 sqmm. Aluminium Armoured
1019Supply and fixing in position 1 m wide Insulation mat made of elastomeric polymers Material (Class -A) of 415V grade as perIS 15642-2006 .Thickness of insulation mat shall be not less than 3 mmto withstand 1.1 KV dielectric strength AS PER IS 15652 : 2006. It should be complete as per specifications & directions of Engineer-in-charge.It should be complete as per specifications & directions of Engineer-in-charge.
1020Supplying and making end termination with brass double compression gland and aluminium lugs for following size of XLPE insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. It should be complete as per specifications & directions of Engineer-in-charge.
10214 Core X 16 sqmm. Aluminium Armoured
10224 Core X 10 sqmm. Aluminium Armoured
10233 Core, X 50 sqmm. Aluminium Armoured
10243 Core, X 35 sqmm. Aluminium Armoured
10253.5 Corex 300 sqmm. Aluminium Armoured
10263.5 Corex 120 sqmm. Aluminium Armoured
1027Supplying , installating, Testing & commissioning ofXLPE insulated & PVC sheathed1.1 KV grade armoured Copper control cables for various equipment through walls / ceilings with appropriate clamps / fixing arrangements and complete with terminationas per manufacturer"s specifications & as directed by Engineer-in-charge.
10286 C x 2.5 Sqmm
10292 C x 4.0 Sqmm
10302 C x 2.5 Sqmm
Disclaimer :